UT Administration Of Dadra And Nagar Haveli Tender
... More
The UT Administration Of Dadra And Nagar Haveli has issued a formal invitation for competitive bids for Extension Of Control Room Building At 66/11kv Kala Substation (4th Call) in Dadra & Nagar Haveli, with an estimated contract value of Rs. 57,90,746. The bid opening date for this tender is 14-05-2025 and the last date for bid submission is 22-05-2025. Interested bidders for UT Administration Of Dadra And Nagar Haveli tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
UT Administration Of Dadra And Nagar Haveli Tender
Building Construction
Eprocure
Opening Date14 May 2025
Closing Date22 May 2025
Tender Amount₹ 57,90,746
Costs
EMD
₹ 1,15,800Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_UTDNH_7578_1Bid Award Id
ViewTender No
06/2025-26/269Tender Authority
UT Administration Of Dadra And Nagar Haveli ViewPurchaser Address
-Website
http://https://daman.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Notice inviting tender for Extension of control room building at 66/11kV Kala substation (4th Call)
Technical Specification
BOQ Items
... More
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(D) Soft rock not requiring Blasting
15.7
-
-
... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.
387.8
-
-
... More
Providing material and labour for filling in plinth WITH UNSCREEN GRAVEL under floors including watering, ramming consolidating and dressing etc. complete.
70.4
-
-
... More
Providing and laying Granular subbase (GSB) for preparing base of road by providing close graded Material, mixing in a mechanical mix plant at OMC(Optimum Moisture Content), carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete.
68.2
-
-
... More
Providing and laying cement concrete work 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete excluding cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base or columns and Mass concrete
40.6
-
-
... More
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
46
-
-
... More
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete.
22.5
-
-
... More
Providing and laying controlled cement concrete M.250 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (A) BEAMS :(ii) Having cross-sectional area more than 0.08Sq.M and upto 0.12 Sq.M
8.15
-
-
... More
Providing and laying controlled cement concrete M.200 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work in (K) Vertical and Horizontial its upto floor two level.
14.1
-
-
... More
Providing and laying controlled cement concrete M.250 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (B) COLUMNS:(ii) Having cross-sectional area more than 0.08 Sq.M and upto 0.18 Sq.M
5.5
-
-
... More
Providing and laying controlled cement concrete M.250 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (A) BEAMS :(iii) Having cross-sectional area more than 0.12Sq.M and upto 0.18 Sq.M
12.2
-
-
... More
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (C) Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor two level.
34.8
-
-
... More
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (C) Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor two level.
29.9
-
-
... More
Providing and laying controlled cement concrete M.250 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (B) COLUMNS:(ii) Having cross-sectional area more than 0.08 Sq.M and upto 0.18 Sq.M
9.4
-
-
... More
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding cost of reinforcement for reinforced concrete work in Lintels, Beams, Girders and Cantilever upto floor two level etc complete as directed by Engineer-incharge.
2.75
-
-
... More
Providing and laying controlled cement concrete M.250 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (A) CHAJJA thickens upto 0.1mt
2.4
-
-
... More
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level
17713
-
-
... More
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventional
8.25
-
-
... More
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in super structure in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventional
25
-
-
... More
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth with cement slurry in (i) Cement mortar 1:3 (1-cement:3-sand)
154.25
-
-
... More
Providing 10mm thick cement plaster in single coat on brick/concrete walls and ceiling with cement slurry finish for interior plastering upto floor two level and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand)
353.3
-
-
... More
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
397.85
-
-
... More
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 laid over and jointed with grey cement slurry including rubbing and polishing etc. complete. (B) 30 mm thick
118
-
-
... More
Providing material and labour for making black granite shelves and door/ window frame having 16 to 18mm thk granite over 10mm thk cement plaster (1 cement: 3 sand) jointed with matching cement slurry including making moulding to edges of stone slab as directed by engineer incharge
13.8
-
-
... More
Providing material, Labor and equipments for Providing and laying integral Cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations :
a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer in charge over the RCC Slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 | 1 cement :5 coarse sand)
128.5
-
-
... More
Applying two coat of wall putty with primer of approved make/ manufacturer on wall to give an even shade including thorughly brushing the surface and making free from mortar drops and other foreign matter and sand papering to smoothen the surface as directed by engineer incharge
507.55
-
-
... More
Distempeing (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall surfaces to give an even shade, over and including a priming coat with alkali resistance primer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth.
507.55
-
-
... More
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete
397.85
-
-
... More
Providing and fixing window having extruded aluminum Colour anodized section frame main outer size 127mm x 38.10mm x 1.35mm @wt. 1.384kg/m, horizontal Four track member size 122.20mm x 31.75mm x 1.10mm@ wt 1.205 kg/m, vertical member of size 122.20mm x 31.75mm x 1.50mm @1.398 kg/mt with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm@ 0.456kg/mt ,vertical member of size 40mm x 18mm x 1.29mm @ 0.456 kg/mt with 5 mm thick transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc complete for window.
24.3
-
-
... More
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacings and frame alround, square or round bars with round headed bolts and nuts or by screws (A) Plain Grill.
610
-
-
... More
Applying general insecticide pest control treatment to floors, cupboards etc including labour materials etc. complete. Using Imidacloprid 30.5 SCas Per IS 6313 part -II( (0.075% concentration by mass) is recommended 10.5ml chemical diluted with 5 liters of water application 0.5 litre chemical /Sqm of surface is recommended as per I.S.
122
-
-
... More
Providing throating or plaster drip and moulding to R.C.C. Chhajja.
34.4
-
-
... More
Construction of B.B. Masonary Chamber of clear inner dimension of 0.60 x 0.45 x 0.45m with 23cm thk brick msonary wall in C:M 1:6 including required excavation, P.C.C 1:5:10- 15cm thk, plaster in and out both side to the masonary and C.C. floor layer and fixing R.C.C manhole cover of sice 0.60m x 0.45m with frame and white/ color wash etc. complete
9
-
-
... More
Providing material and labour for laying PLINTH PROTECTION including excavation of 30 cm depth and Filling with dry bricks bats of 20 cm thick and top layers C.C. 1:2:4 ( 1 cement 2 coarse sand: 4 graded stone aggregate 20m nominal size)50mm thk finished in proper grade and slop etc. complete as directed by engineer-in-charge
37.6
-
-
... More
Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre × 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. includina testina of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
48
-
-
... More
Constructing water harvesting pit as per attached drawing
1
-
-
... More
Demolition of Brick work with both side plaster including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar.
9.2
-
-
... More
Supplying and fixing reinforced concrete heavy duty non-pressure pipes with collars for culverts including setting and joining the pipes in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2 of following internal diameters.(ii) 450mm dia.
10
-
-
... More
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like
490
-
-
... More
Applying priming coat over new steel and other metel surface after and including preparing the surface by throughly cleaning, oil,grease, dirt and other foreign matter and scoured with brushes fine steel wood, scrapers and sand paper with ready mixed priming paint brushing red lead.
45
-
-
... More
Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multi strand copper wires upto max length of 10 mt, in below type of pipe erected with 6A Tissino Type ISI marked flush type switch / bell push and accessories erected on Metal / PVC/Wooden Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
( h) with oval conduit /PVC casing capping double lock type erected concealed in wall/ceiling complete (Cable Make: RR kable, Havell's, Finolex)
28
-
-
... More
Point wiring for independent PLUG with following size mains earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires upto 10 mt length, in following below of pipe erected complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with earth continuity connection erected on Metal / PVC/Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic/Laminated sheet. [A] For 6 amp plug and 6 amp switch with 2-1.5 sq. mm Cu. Mains from near by switchboard/db board upto 6 mt.
( h) with oval conduit /PVC casing capping double lock type erected concealed in wall/ceiling complete (Cable Make: RR cable, Havell's, Finolex)
8
-
-
... More
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (C) With oval conduit /PVC casing capping double lock type (b) 2 wire 2.5 sq. mm(Cable Make: RR Kable, Havell's, Finolex)
45
-
-
... More
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm(Cable Make: RR Kable, Havell's, Finolex)
15
-
-
... More
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on residual current device having 10 KA short circuit breaking capacity and 30 mAmp. Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for rated leakage at nominal ten volt, complete erected including all materials lugs screws etc. completed
[b] 32A / 40A, 2 pole Single Phase
Cat. II
4
-
-
... More
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on residual current device having 10 KA short circuit breaking capacity and 30 mAmp. Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for rated leakage at nominal ten volt, complete erected including all materials lugs screws etc. completed
[f] 63A, 4 pole Three Phase
Cat. II
1
-
-
... More
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency.
"[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of 15 Kgs."
1
-
-
... More
Point wiring for independent PLUG with following size mains earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires upto 10 mt length, in following below of pipe erected complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with earth continuity connection erected on Metal / PVC/Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic/Laminated sheet. [B] 6/16A Plug and 16 amp switch with 2-2.5 sq. mm Cu. Mains from mcb d b boards.
2
-
-
... More
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy erected with earthing. [ Make shall be approved by Engineer in Charge]
8
-
-
... More
Supplying and erecting approved make of tube fitting with One no T-5 tube 24/ 28 W with Electronic ballast with each tube separately THD less than 10 & built in adaptors, GI / PVC housing & mirror optic reflector, suitable to work on 120V - 300V, A.C. supply with connector and adapter if required. [Make of fitting & tube may be differ& fitting shall be providing with tube] Cat-III
12
-
-
... More
Supplying & erecting approved make 230 V , 50 Hz Operating Voltage low noise decorative Roof Mounting Exhaust fan having square frame and Slitted guard with mounting accessories, necessary pipings and fittings.
(A) 300x300x200mm with 1250 RPM
6
-
-
... More
Supply and Erection of 1100 Volts 3.5 Core 120 Sq. mm Armoured Aluminium Cable. As per specifications.Make: Havells / KEI / RR Kabel
130
-
-
... More
Supply and Erection of 1100 Volts 2 Core 16 Sq. mm Armoured Copper Cable. As per specifications.Make: Havells / KEI / RR Kabel
140
-
-
... More
Supply and Erection of 1100 Volts 2 Core 6 Sq. mm Armoured Copper Cable. As per specifications.Make: Havells / KEI / RR Kabel
160
-
-
... More
Supply and Erection of 3 Phase 440 Volts 3 Circuits RYB-N ACDB along with 5 Nos 4 Pole MCB C Curve 10 kA, 10 Nos. 2 Pole MCB C Curve 10kA along with 125 Amps Input MCCB. As per Specifications
1
-
-
... More
Supply and Erection of DC Junction Box along with 63 Amps DC MCB 10kA along with Input/Output terminals as per requirement.
2
-
-
... More
Supply and Erection of 3 phase 440 Volts 50 KVA Voltage Stabilizer with range 340 Volts to 480 Volts Make: CONSOL NEOWATT/ SERVO with Input MCCB & Bypass Switch. As per specifications.
1
-
-
... More
Supply and erection of emergency DC lighting (illuminating inside and outside control room with 50w LEDs) fed from existing 110 Volt source along with control & wiring including logic design for Auto ON/OFF in case of AC failure.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements