Costs
EMD
₹ 21,47,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Contact
Tender Id
167297Tender No
167297Tender Authority
Nava Raipur Atal Nagar Vikas Pradhikaran ViewPurchaser Address
-Website
http://eproc.cgstate.gov.in
BOQ Items
6615
-
-
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
390
-
-
Concrete of M25 grade
2900
-
-
11399
-
-
1651
-
-
7.5
-
-
143
-
-
12700
-
-
Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm
2900
-
-
Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
700
-
-
manufacturers recommendation and injecting for post - constructional anitermite treatment (excluding cost of chemical emulsion):
Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
700
-
-
Thermo-Mechanically treated bars FE 500D
359389.5
-
-
165
-
-
Foundations, footings, base of columns and plinth beam in any shape and size.
3000
-
-
Window sills, anchor blocks, string course, bends, copings, bed plates and like.
24
-
-
Edge of slab, breaks in floor and walls upto 200mm.
440
-
-
Columns, Pillars, Piers and likes- rectangular or square in shape
2816
-
-
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
8337
-
-
Beams, lintels, cantilevers & walls
2381
-
-
Weather shade, chhajja, Cornices and mouldings
150
-
-
Stair cases of all types excluding spiral and folded plate type, including risers and landings
365
-
-
Cement Mortar 1:6 (1 cement : 6 coarse sand)
3600
-
-
3516
-
-
Cement Mortar 1:4 (1 cement : 4 coarse sand)
399
-
-
401
-
-
414
-
-
350
-
-
379
-
-
5 mm thickness
379
-
-
with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam
sheet mitred at corners and joined with 2 Nos of 150mm long brackets of
15x15mm M.S. square tube, the vertical door profiles to be reinforced with
19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather
seal to be provided through out the frame. The door frame to be fixed to
the wall using M.S. screws of 65/100mm size complete as per
manufacturers specification and direction of Engineer-in-Charge.
237
-
-
made out of a one piece Multi chamber extruded PVC section of the size
of 762mm X 25mm or less as per requirement with an average wall
thickness of 1mm ± 0.3mm. PVC foam end cap of size 23x10mm are
provided on both vertical edges to ensure the overall thickness of 25mm.
An M.S. tube having dimensions 19mm x 19mm is inserted along the
hinge side of the door. Core of the door shutter should be filled with High
Density Polyurethane foam. The Top & Bottom edges of the shutter are
covered with an end-cap of the size 25mm X 11mm. Door shutter shall be
reinforced with special polymeric reinforcements as per manufactures'
specification.
75
-
-
For fixed portion
1950
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
1806.94
-
-
3757
-
-
Single rebate/ mullion 80mmx50mm size,1.6mm thick sheet
474
-
-
35 mm. thick (single leaf)
195
-
-
125x85x5.50 mm (Heavy Type)
386
-
-
150x125x27x5mm
350
-
-
300x16 mm
262
-
-
300x16x5mm
247
-
-
230
-
-
150x10mm
236
-
-
68
-
-
9403
-
-
110
-
-
Size of Tile 600x600 mm
7500
-
-
Size 600x600mm
7500
-
-
matching pigment including rubbing and polishing to edge moulding to give high gloss finish.
Granite stone black
250
-
-
Granite stone black
270
-
-
601
-
-
and upto 0.50 sqm)
395
-
-
174
-
-
494
-
-
17291
-
-
18522
-
-
8099
-
-
25248
-
-
20012
-
-
12500
-
-
On new work (two or more coats)
20012
-
-
396
-
-
2973
-
-
SS Grade 304
733
-
-
6258
-
-
Hardware Set : SS 304 Ball Bearing Butt Hinges 100x75x3mm, Suitable for 120 Kg, Make: Hormann , Door Closer 9903 with Standard Arm-Make : Hormann, Single point surface panic latch XDL5760SV, Silver finish -Hormann, Two point surface panic latch XDV5120SV, Silver finish -Hormann, External lever handle, 1185, with locking arrangement, Silver finish -Hormann
Fire rated Glass 2 Hours 6 mm thick 200x300 mm
Double Adhesive Side Roll ( Ceramic Tape) Kerfai2000 Length.
Shutter (1500 X 2100mm approx.)
19
-
-
1564
-
-
650
-
-
i) First layer of slurry of cement @ 0.488 kg/sqm mixed with waterproofing cement compound @ 0.253 kg/sqm. This layer will be allowed toair cure for 4 hours.
ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with waterproofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
99
-
-
Electric resistance or induction butt welded tubes Grade-300
5500
-
-
242
-
-
587
-
-
14500
-
-
438
-
-
144
-
-
144
-
-
2mm thick corrugated (2.5
50
-
-
i) 1st layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.
ii) 2nd layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.
iii) 3rdlayer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with coarse sand @ 1.289 kg/sqm and water proofing cement compound @ 0.07 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. iv) 4th and final layer of brick tiling with cement mortar (which will be paid for separately)
For the purpose of measurement the entire treated surface will be measured.
1410
-
-
1410
-
-
141
-
-
1410
-
-
1410
-
-
1650
-
-
3mm thick
430
-
-
5mm thick
2.25
-
-
106
-
-
On new work (two or more coats) including a base coat of white washing
870
-
-
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
5500
-
-
210
-
-
210
-
-
105
-
-
Serrated with central bulb (225mm wide, 8-11mm thick).
96
-
-
With 20x20 mm square bar
13
-
-
Rectangular shape 600x450mm internal dimensions
4
-
-
100 mm diameter pipe
8
-
-
150 mm diameter pipe
4
-
-
8
-
-
4 x 16 sq. mm.
50
-
-
2 x 10 sq. mm
50
-
-
4 X 16 sq. mm (22 mm)
4
-
-
2 X 10 sq. mm (19 mm)
4
-
-
INCOMER- 1No.63A FP MCCB(35 KA), Metering & Indication- 1 set of phase indicating lamps BUS-BAR- 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves. OUTGOINGS- 1 Nos.32A FP MCB & 2 Nos.32A SP MCB
1
-
-
50
-
-
3.0 H.P. Head Mt.15-30, Discharge LPM 615-195
2
-
-
3
-
-
100
-
-
Fabricating pipes from steel plates (all thickness)
5 to 8 mm
0.5
-
-
80mm dia.
130
-
-
80 mm dia. PN-1.6.
3
-
-
150 mm dia. PN-1.6.
1
-
-
80 mm dia. (Class -PN 1.0 rating)
2
-
-
80 mm dia.
3
-
-
80mm dia PN-1.6
1
-
-
12
-
-
32 mm nominal outer dia .Pipes.
162
-
-
50 mm nominal outer dia .Pipes.
2052
-
-
2
-
-
32 mm nominal bore
2
-
-
50 x 32
1
-
-
80x 50
1
-
-
100 mm dia. (Class -PN 1.6 rating)
4
-
-
150 mm dia. (Class -PN 1.6 rating)
4
-
-
1330
-
-
Construction of granular sub-base by providing close graded Material, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401
Plant Mix Method
Grading -VI Material
462
-
-
200
-
-
PCC Grade M30 with minimum cement content@375Kg/cum
315
-
-
Two coats on new surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
127.75
-
-
60mm thick Plain precast interlock concrete block
420
-
-
491
-
-
109
-
-
3.5
-
-
100
-
-
20 mm nominal outer dia .Pipes.
100
-
-
25 mm nominal outer dia .Pipes.
160
-
-
32 mm nominal outer dia .Pipes.
95
-
-
32 mm nominal outer dia .Pipes.
120
-
-
50 mm nominal outer dia .Pipes.
150
-
-
50 mm dia pipe
220
-
-
75 mm dia pipe
115
-
-
110 mm dia
2040
-
-
160 mm dia pipe.
50
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
50 mm
60
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
75 mm
30
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
110 mm
39
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
150 mm
8
-
-
Double
15
-
-
Double
15
-
-
Vent covel
110 mm
6
-
-
Access door cap
75 mm
26
-
-
Access door cap
110 mm
41
-
-
P trap 110mmx110mm long
33
-
-
Nahani trap 110x75mm
46
-
-
Multi floor trap 110
25
-
-
21
-
-
wall hung WC with PP seat cover, Hinges accessiories set. Size: 360X545X365
FLS-WHT-5951
28
-
-
approved quality:Jaquar FLR-5041N or Equivalent as approved by NRDA
2 Way Bib Cock With Wall Flange
28
-
-
Hand Shower (Health Faucet) with 8mm Dia,
1.2 Meter Long Flexible Tube & Wall Hook
28
-
-
Under Counter Basin
Size (mm) 550x360x120
22
-
-
Waste coupling 32mm Size Full Thread
with 80mm height
22
-
-
Urinal with Fixing Accessories Set.
Size: 375 x 315 x 620
9
-
-
1145x510 mm bowl size 560x410x241 mm
1
-
-
Size 600x450x200mm
8
-
-
32 mm dia
31
-
-
20 mm nominal bore
45
-
-
25 mm dia
21
-
-
32 mm dia
14
-
-
50 mm nominal bore
18
-
-
58
-
-
Jaquar FLR-5047N or Equivalent as approved by NRDA
Bib Cock (Straight Line Model) With Wall Flange
28
-
-
Long Body Bib Cock with Wall Flange
84
-
-
Pillar Cock Auto Closing System with 65mm Extension Body
18
-
-
84
-
-
Toilet Roll Holder with Flap
60
-
-
Jaquar ACN-1131N or Equivalent as approved by NRDA
Soap Dish Holder
47
-
-
Soap Dispenser - Push Button SDR-WHT-DJ0010F capacity: 0.8L material: ABS finish: white/smoked
16
-
-
Hand Dryer - Smartflow HDR-WHT-M04A material: ABS
finish: white
15
-
-
Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT ) Also available CQT-23069K Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible )
28
-
-
Towel Ring Round with Round Flange
55
-
-
Single Towel Rail 600mm Long Also available
ACN-1111BNM Single Towel Rail 450mm Long
12
-
-
15
-
-
15
-
-
For 100 mm dia pipe
113
-
-
For 75 mm dia pipe
113
-
-
48
-
-
56
-
-
1
-
-
100mm nominal inner dia pipes
5
-
-
100mm dia
15
-
-
100mm dia
9
-
-
7
-
-
6
-
-
32 mm dia
1
-
-
160 mm dia pipe. (for Sewerage)
200
-
-
200 mm dia pipe. (for Sewerage)
200
-
-
32 mm nominal bore
4
-
-
50 mm nominal bore
2
-
-
Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
9
-
-
M-20 Grade
3.23
-
-
0.13
-
-
8
-
-
All types of soil
200mm dia
50
-
-
160 mm nominal size dia.
51
-
-
6.41
-
-
150 mm dia
1
-
-
150 mm clamp.
1
-
-
150 mm dia
1
-
-
1
-
-
Capacity 6 kg
60
-
-
60
-
-
Capacity 9.0 ltrs
2
-
-
Capacity 22.5 Kg
2
-
-
20
-
-
20
-
-
15
-
-
500
-
-
200
-
-
25mm dia.
40
-
-
50mm dia.
40
-
-
100mm dia.
1015
-
-
150mm dia.
400
-
-
150mm dia. pipe
400
-
-
100mm dia. pipe
1000
-
-
80mm dia. pipe
30
-
-
100mm dia
5
-
-
150mm dia
2
-
-
150mm dia
2
-
-
100mm diameter
4
-
-
150mm diameter
2
-
-
6
-
-
3
-
-
12
-
-
12
-
-
1000
-
-
2
-
-
12
-
-
8
-
-
8
-
-
16
-
-
Size 600 mm x 600 mm x 500 mm
8
-
-
10
-
-
2-Loop
2
-
-
Pull Station Type Manual Call Points (MCP)
60
-
-
Supply, testing and commissioning of response indicator
60
-
-
Supply, testing and commissioning of loop isolate module
3
-
-
Supply, testing and commissioning of UL listed hooters
60
-
-
Supply, testing and commissioning of control module
60
-
-
Photoelectric type Smoke detectors
100
-
-
Multi-Sensor combined (Photo + Thermal) detectors
150
-
-
2 core 1.5 Sqmm
1000
-
-
4 core 2.5 Sqmm
500
-
-
2
-
-
1
-
-
2
-
-
1
-
-
1
-
-
1
-
-
15
-
-
40 mm dia
400
-
-
3.5C X400 sqmm ( Transformer to LT panel)
100
-
-
3.5C X 150 sqmm
410
-
-
3.5C X70 sqmm
250
-
-
3.5C X50 sqmm
500
-
-
3.5C X25 sqmm
500
-
-
4C X10 sqmm
300
-
-
2C X10 sqmm (AC)
300
-
-
2x 6 sqmm
100
-
-
3.5x400sqmm
10
-
-
3.5x150 sqmm
8
-
-
3.5x70 sqmm
8
-
-
3.5x50 sqmm
15
-
-
4x25 sqmm
16
-
-
4x 10 sqmm
10
-
-
2C X10sqmm
8
-
-
2C X6 sqmm
6
-
-
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and depth above 300 mm and upto 450mm made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ameters ets as per specifications including powder coating painting with busbars, switchgears and other accessories etc complete as required as per direction of Engineer
INCOMER
4 pole 1CB, 1250A, 50KA-2 nos
4 pole 1CB, 1600A, 50KA for D.G in commer - 1 nos
BUS-BAR
1 Set of 630A 4P Aluminium Bus Bar with colour coded PVC Sleeves
analog type 0-1000 amp ammeter of size 100x100 (NS) (1no.)
analog type 0-1000 volt voltmeter of size 100x100 (NS) (1no.)
selector switch fro voltmeter (1no.)
selector switch fro ammeter (1no.)
230 volt LED type indicating lamp (4nos.)
OUTGOINGS
4P MCCB, 320A 1 NOS as out going 35KA - 4 nos
4P MCCB, 250A 1 NOS as out going 35KA - 4 nos
4P MCCB, 100A 1 NOS as out going 35KA - 8 nos
1
-
-
Supplying and fixing on surface/ recess prewired vertical type 4 way (4+12)double door, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as required
INCOMER
4P MCCB, 100A 1 NOS as out going 35KA -1 no
OUTGOINGS
4P MCCB, 63A , 35KA -4 nos
4P MCCB, 40A , 35KA-2 nos
6
-
-
Supplying and fixing on surface/ recess prewired vertical type 4 way (4+12)double door, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as required
INCOMER
4P MCCB, 63 , 35KA -1 nos
OUTGOINGS
4P MCCB, 32A , 35KA-4 nos
2
-
-
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and depth above 300 mm and upto 450mm made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ameters ets as per specifications including powder coating painting with busbars, switchgears and other accessories etc complete as required as per direction of Engineer
INCOMER
4P MCCB, 250A 1 NOS as out going 35KA
BUS-BAR
1 Set of 300A 4P Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
4P MCCB, 100A as out going 35KA - 1nos
4P MCCB, 40A 35KA -8 nos
4P MCCB, 63A 35KA -8 nos
all necessary metering CT/PT ,LED light .kwh meter etc
3
-
-
INCOMER
4P MCCB, 320A 1 NOS as out going 35KA
BUS-BAR
1 Set of 300A 4P Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
4P MCCB, 63A 35KA -6 nos & 32 A SP MCB -4 NOS & 4 P 40 A RCCB - 6 NOS
6
-
-
1 No. 40A-63A 4pole MCCB as Incomer;
16 Nos. 6-32A SP MCB C series 10kA as out going feeder.
52
-
-
Short Point
250
-
-
Medium Point
410
-
-
Long point
470
-
-
concealed PVC conduit point wiring with modular type 3 pin 5
amp socket outlet and 5 amp switch including cost of base and
cover plate and G. I. box etc. as required
40
-
-
3 x 1.5 sqmm in 20 mm conduit
4200
-
-
3 x 2.5 sqmm in 20 mm conduit
4500
-
-
100mm x 100mm x 60mm deep
100
-
-
125mmx75mm
75
-
-
Fan Regulator Electronic, step type moving all round
210
-
-
5/6 amps one way switch
12
-
-
210
-
-
1200mm sweep
210
-
-
20
-
-
sizes heavy duty (continuous running) 1400 rpm exhaust fan in
existing opening in wall including earthing etc. complete as
required.
300 mm sweep
6
-
-
sizes fancy exhaust fan having built in lovers in existing opening
in wall including earthing etc. complete as required.
225 mm sweep
48
-
-
36 watt, size 600 x 600mm
310
-
-
12 Watt
300
-
-
9 Watt
90
-
-
36 watt -4 feet
60
-
-
18 watt -4 feet
50
-
-
200
-
-
4
-
-
20mm
200
-
-
25mm
3000
-
-
32mm
100
-
-
225 mm width X 50 mm depth X 1.6 mm thickness
450
-
-
225 mm width X 50 mm depth X 1.6 mm thick
30
-
-
250 mm x 25 mm x 1.6 mm (3 compartments)
1000
-
-
250 mmx 250 mm x 60 mm - 75 mm (3 compartment)
200
-
-
including, connections, testing and commissioning etc. as
required.
DOL three phase 32 amps
6
-
-
4C X16 sqmm (SMDB to DB'S )
350
-
-
4x 16 sqmm
10
-
-
Short Point
120
-
-
Medium Point
180
-
-
Long Point
180
-
-
Extra Long Point I
205
-
-
Extra Long Point II
150
-
-
Short Point
15
-
-
Medium Point
25
-
-
Long Point
15
-
-
32A with C series MCB
45
-
-
20A with C series TP MCB
45
-
-
32A with C series TP MCB
65
-
-
3 x 4 sqmm in 25 mm conduit
3000
-
-
3 pin 5/6 amp socket outlet
25
-
-
6 pin 15/16 amp socket outlet
45
-
-
30 KVA/24KW UPS including battery bank with 30 Minutes Battery Backup And Rack As per requirement
4
-
-
200
-
-
1
-
-
adaptor with ESE Air Terminal & various
accessories( fasner , guy wire , ring fasner, huk
etc)
Length – 5mtr
Pipe – Jindal , Dia. -50mm
Thickness – 3.4mm
Base plate – (300x300x6)mm
1
-
-
3
-
-
1
-
-
1
-
-
50
-
-
10
-
-
50
-
-
With 3 metre long GI Pipes and 50 kg back filling compound
4
-
-
50
-
-
800
-
-
1000
-
-
SITC of RJ-11 Telephone jack type socket with box and plate complete
100
-
-
T.V antenna socket out let
30
-
-
1200
-
-
4x10 Sq.mm
500
-
-
4x10 Sq.mm
8
-
-
12
-
-
6 metre high, dia 130mm at bottom and 70mm at top, base plate size 220x220x12mm, foundation bolts 600mm long
24
-
-
6 metre high
24
-
-
24
-
-
not more than 45 watt
24
-
-
10 sq.mm
100
-
-
240
-
-
18 watt
25
-
-
Feeder Pillar:
INCOMER
1No. 63A FP MCCB(35 KA)
1No. 63A FP Contactor, AOM switch & Timers for 24 Hrs. setting
Metering & Indication
1 set of phase indicating lamps
BUS-BAR
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves
1
-
-
Engine :-water cooled diesel engine of suitable BHP for rated alternator at 1500 rpm, turbo charged, direct injection type, 4 stroke, 4/6 cylinder including specified size fuel tank of approved design and shape duly calibrated and painted with one coat of primer and two coats of synthetic enameled paint of approved colour, residential type silencer with exhaust MS pipe (upto 2 metre beyond silenser) duly wrapped with asbestos rope of legging of specified quality and specification.
Alternator: rated at 150 KVA, 415 volts at 1500 RPM,suitable for 50 Hz 3-Phase system, AC Supply with 0.8 lagging power factor
AMF Panel :Cubical, compartmentalized, AMF panel board with all suitable size power and control contactors, switches,meters and other accessories, internal wiring, connection,inter-connection etc. for trouble free smooth functioning of DG Set with power pack of 12V/24 DC as required.
Base Plate : Common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting etc. as required
Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of engine and alternator, extraction, discharging hot air in to the atmosphere as per pecifications
Fuel -level information :Fuel tank shall be install with remote sensing unit for fuel tank level
work shall be included with all civil worl like foundation ,shed of D.G set & interconnection between D.G and Main LT panel.
2 year warranty and Quartly visit the D.G set for 2 year ,
1
-
-
60
-
-
Max 200 Mbps incoming & outgoing bandwidth, Smart H.265/ H.264 codec decoding, Upto 8 MP resolution preview and playback, Frame Rate: 1-15 FPS(8 MP); 1-25/30 fps for rest of Resolutions; Support 4 SATA HDDs up to 8 TB each, 2 USB (1 USB3.0,1 USB2.0), 1HDMI /1 VGA simultaneous video output , Two way talk 1Channel Input, 1Channel Output RCA, 1RJ-45port (10/100/1000Mbps),
3
-
-
1
-
-
15
-
-
10
-
-
13
-
-
6
-
-
6000
-
-
4
-
-
4
-
-
8
-
-
Double Leaf Door.
2
-
-
Single Leaf Door.
2
-
-
100
-
-
1
-
-
5
-
-
300
-
-
300
-
-
300
-
-
300
-
-
300
-
-
15
-
-
6
-
-
500
-
-
500
-
-
A. Type : Passenger lift
B. Load : 13 passenger/ 884 Kg
C. Speed : 1.5 metre per second
D. Contol : AC2
E. Operation : Microprosser based simplex collective selective with/without lift attendent
F. Total rise : About 9 mtrs
G. Landings : 4 All on same side
H. Floors served : G,1,2
I. Signals : Digital car position indicator, car travel direction indicator in car & at all landings
J. Lift shaft size : About 2500 mm width X 1900 mm depth, finished with plaster (size as per actual site conditions)
K. Lift car size : About 2000 mm width X 1100 mm depth
L. Car entrance : Minimum Clear opening 900 mm wide X 2000 mm high protected with car door
M. Landing entrance: Clear opening 900 mm wide X 2000 mm high protected with landing door
N. Car door : Stainless steel /Glass Door two pannel telescopic/centre opening flush type
O. Landing door : Stainless steel /Glass Door two pannel telescopic/centre opening flush type
P. Door operation: Automatic electric power operated door with infra red protection
Q. Car interior : Stainless steel pannel with hair line/ mirror/moon rock finish on all sides
R. Car floor : Hard wood covered with PVC/ marblex tiles
S. Car ceiling & lighting : Fluorscent lighting concealed by suspended false ceiling with plain acrylic diffuser. The frame of suspended false ceiling shall be of powder coated aluminium
T. Car ventilation : Pressure fan with anodised aluminium grill
U. Emergency lighting in car: Battery operated Emergency lighting in the lift car
V. Intercom system : Battery operated Intercom system in lift car, machine room and control room
W. Emergency alarm : Battery operated alarm bell system in lift car & contol room
X. Position of machine room: Directly above the lift shaft
Y. Electric power supply : AC 415 Volts 3 phase 50 Hz terminated in machine room
Z. Fire man switch : Fire man switch at main landing termanal
4
-
-
1
-
-
1
-
-
1
-
-
200
-
-
6
-
-
1
-
-
200
-
-
4
-
-
40
-
-
200
-
-
6
-
-
2
-
-
1set of 33/ 3KV / 110/ 3 Volt, 100 VA burden & accuracy class 0.5, single phase construction, dry type cast resin PT
3 Nos. of dual core 100/5-5A, 15 VA burden, accuracy class 0.5, 33 KV cast resin CTs .The short circuit ratio should be 25KA for 1 sec
One Set of Phase Indicating Lamps.
2 Sets of HRC fuses with fuse base (H.T. Fuse - 1A & LT fuse 2-6A)
2 Nos. indoor cable end box for suitable for 3C x 300 sq.mm. 33 KV(E), aluminium conductor XLPE Ar. cable (Incoming & Outgoing cable).
1 No. approved digital Trivector meter with MDI in KVA of accuracy class - 0.5.
1
-
-
2190
-
-
625
-
-
1.0-1.3 TR
21
-
-
1.5-1.8 TR
42
-
-
2 -2.5TR
14
-
-
2.6-3.3 TR
92
-
-
4 TR
32
-
-
25
-
-
190
-
-
6.4-15.9 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
3200
-
-
19.1-41.3 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
2350
-
-
850
-
-
699.99
-
-
5500
-
-
35
-
-
620
-
-
Evaluation Notes How It Works ?
Potential Partner
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%