Nava Raipur Atal Nagar Vikas Pradhikaran Tender
Nava Raipur Atal Nagar Vikas Pradhikaran Tender
Costs
EMD
₹ 83,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Construction Of Nava Raipur Sports Complex-phase-1 Works At Sector-
Description
Contact
Tender Id
166288Bid Award Id
ViewTender No
166288Tender Authority
Nava Raipur Atal Nagar Vikas Pradhikaran ViewPurchaser Address
-Website
http://eproc.cgstate.gov.in
BOQ Items
High Back Revolving Chair
Upholstry/Frame: One piece ply in seat & back with foam & polyfill and leatherite upholstery with silver bidding all around
Seat size : 500 mm (w) x 480 mm (D)
Back size : 500 mm (w) x 720 mm (H)
Arms: Chrome finish arms with leatherite foam pad
Standard Mechanism : Torsion bar Mechanism
Height Adjustment : Gas Lift
Base : Chrome plated base with twin wheel castors, as per Specification and as directed by Engineer in Charge.
50
-
-
2
-
-
Fabricated with GI (B-class) pipes &
Tubes
Maximum loading weight: 120 kg
Thickness: 4 mm
Length: 1100 mm
Width: 710mm
Height: 1150mm
Seat Size; 320x300 as per Specification and as directed by Engineer in Charge.
2
-
-
SIZE:- 1650 X 900 X 750SIDE UNIT top 25mm PF, body & facia 18mm LCB. The unit has two drawers & one filing on one side and one openable shutters with shelf on other side made up of 18mmLCB Size:900X450X725
Keyboard tray with mouse -CRCA CPU -CRCA [Prelam Particle board (PLPB) & MDF Must be exterior grade Only],as per Specification & direction of Engineer-In-Charge.
50
-
-
100
-
-
5 watt per metre LED Strip ( warm white , white ,blue & pink )
300
-
-
4320
-
-
1.8-2.2 TR
17
-
-
2500
-
-
4 core 2.5 sqmm
55
-
-
Cement Mortar 1:3 (1 cement : 3 coarse sand)
5258
-
-
10
-
-
1000
-
-
100mm x 100mm x 60mm deep
160
-
-
5480
-
-
25 mm dia
85
-
-
120Watt
35
-
-
Set of kettlebells (8-32 kg)
Specifications: Cast iron, chrome-plated, 8-32 kg range as per Specification and as directed by Engineer in Charge.
2
-
-
31
-
-
1
-
-
40
-
-
approved quality:Jaquar FLR-5041N or Equivalent as approved by NRDA
2 Way Bib Cock With Wall Flange
230
-
-
Long Body Bib Cock with Wall Flange
212
-
-
5
-
-
2 core 1.5 Sqmm
9000
-
-
80mm diameter
14
-
-
6 pin 15/16 amp socket outlet
312
-
-
4
-
-
Seat & back assembly : seat & back cushion is made up of PU foam uphostered with leatherite/ fabric
Structure/ Frame : combination of Steel frame & plywood covered with U foam and uphostered
Leg frame Assembly : made of chrome plated steel tube covered all around the sofa.
Size-70� (L) x 30� (D) x 32� (H) , as per Specification and as directed by Engineer in Charge.
10
-
-
5
-
-
Frame:
Material: Powder-coated steel/aluminum alloy for durability and corrosion resistance.
Thickness: Minimum [e.g., 1.5 mm] for structural stability.
Seat and Backrest:
Material: High-density polyurethane or molded plastic.
Upholstery: Synthetic leather or weather-resistant fabric, UV stabilized.
Cushioning: High-density foam, minimum thickness of [e.g., 50 mm].
Armrests: Ergonomically designed with the same finish as the seat.
Legs/Base: Non-slip rubber or PVC caps to prevent movement and floor damage.
3. Design and Dimensions
Dimensions (approximate):
Seat Height: [e.g., 400-450 mm].
Seat Width: [e.g., 450-500 mm per chair].
Total Height: [e.g., 900 mm].
Ergonomics: Comfortable seating angle and proper lumbar support.
Aesthetics: Colors to match [Specify color scheme, e.g., team colors or neutral tones].
Portability: Lightweight but sturdy construction for ease of movement.
4. Performance Requirements
Weather-resistant: Able to withstand outdoor conditions (sunlight, rain, humidity).
Load Capacity: Capable of supporting a minimum of [e.g., 150 kg].
Anti-corrosion: Tested for resistance to rust and corrosion.
5. Certification
The material and construction must comply with [Specify relevant standards, e.g., ISO, BIS].
Provide certifications for fire-retardant properties if required.
6. Quality Assurance
Manufacturer's warranty documentation to be provided.
Supplier to submit a sample unit for approval prior to full delivery.
Third-party inspection may be conducted for quality assurance.as per Specification and as directed by Engineer in Charge.
5
-
-
60
-
-
80 mm dia. PN-1.6.
4
-
-
1994.3741
-
-
2
-
-
125 mm
120
-
-
Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter).
PVC door shutter
267.75
-
-
2x 6 sqmm
1050
-
-
300
-
-
282
-
-
95
-
-
Extra Long Point I
132
-
-
9 Watt
282
-
-
2353
-
-
70
-
-
31330
-
-
190
-
-
1500
-
-
Short Point
128
-
-
All Refrigerant copper piping for VRV / VRF system having 18G Thickness or Recommended Thickness by VRV/VRF Manufacturer along with insulation and all accessories like, T, Bend, Elbows complete. piping shall be pressure tested for 400 PSI, between indoor & outdoor units with 19mm/13mm Nitrile rubber insulation. All piping inside the room shall be properly supported on perforated trays with hanger and exposed piping shall be properly covered with UV treated cloth / Aluminium faced & should be in a closed tray with properly supported.
200
-
-
10
-
-
1no. Panel for controlling incomer with VCB, CTs, PTs, digital Ammeter/voltmeter/Energy meter, O/C and E/F relay/other relays as per requirement, etc. The cable chamber shall have 3 nos., 20kV, 10 kA distribution class valve type lightning arresters.
2 no. Panel for controlling 5MVA power transformer with VCB, digital meters, Static Energy Meters, transformer protection relays, auxiliary relays, etc.
The unit shall be as per the attached technical specification.
1
-
-
50
-
-
12
-
-
For fixed portion
1820
-
-
8 core 2.5 sqmm
60
-
-
3 x 1.5 sq. mm
8000
-
-
250 mm x 25 mm x 1.6 mm (3 compartments)
100
-
-
5
-
-
Set of resistance bands (light, medium, heavy)
Specifications: Durable rubber, 3-level resistance, 1-meter length as per Specification and as directed by Engineer in Charge.
2
-
-
15130
-
-
i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours.
ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
iii) 3rd course of applying blown or residual bitumen applied hot @ 1.7 Kg. per sqm of area.
iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg. per sqm of area.
992
-
-
6
-
-
Size above 300x300mm
2690
-
-
100 mm Dia.
10
-
-
a)Solar Photo voltaic Module of capacity 330W porabove,manufactured in India,conformingto IS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2.Solar Photovoltaic Module conversion efficiency shall not be less than16.5%.PVmodulesused in solar power plants/systems must be warranted for their output peakwatt capacity,which should no tbe less than 90%at the end of 10years and 80% at the end of 25 years.
b)PowerConditioningUnit(PCU)of350-800V DC In put voltage range and 400VAC,three phase,4wire,50Hz+/-2.5Hz,output voltage suitable to generate AC Power with efficiency not less than 97%,total harmonic distortion lessthan 3%and suitable for ambient temperature from 0to50 degreeC.The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency
c) Data Monitoring System complete with accessories.
d)Fixing of Array junction box& Main junction box with IP65 protection and termination arrangement for incoming and outgoing cablealong with glands,lugs and other accessories etc. as required.
e) Lightning and surge voltage protection.
f)Connections & Inter connections by supplying &fixing required size XLPE insulated copper conductor1.1kVgrade armoured power and control cables between solar modules,mainpower cable to grid supply PCU unit along with supplying &fixing of necessarychannel/conduit lugs and other accessories etc.as required.
100
-
-
14
-
-
150 x10mm
60
-
-
Medium Back Revolving Chair
Upholstry/Frame: One piece ply in seat & back with foam & polyfill and leatherite upholstery and wooden bidding all around
Seat size : 500 mm (w) x 500 mm (D) Back size : 500 mm (w) x 580 mm (H)
Arms: Wooden arms with melamine finish
Standard Mechanism : Torsion bar Mechanism
Height Adjustment : Gas Lift , Base : Wooden base with twin wheel castors, as per Specification and as directed by Engineer in Charge.
50
-
-
40 mm
7500
-
-
100
-
-
Access door cap
110 mm
45
-
-
Panel shall be secured to the support system by means of the panel face fixing clamp in ALMgSi0.5, ENAW 6063- T6 Surface oxidised, at appropriate centres. This concealed sliding clamp allows for free thermal movement of the panel. The fixing joint will have a flush T- shaped join to f3 mm width(T-joint). The Panel ends are sawcut, with an internal splice profile to connect panels ends or a“Top head profile” joint with U- shape groove joints. The panels shall be mounted on the MS sub structure as per approved design and specifications.(The Sub-structure shall be designed by contractor as required and shall be paid separately in relevant item.)Approved make : Hunter Douglas, Luxlon, Anutone,NLF
850
-
-
69806
-
-
Supply, testing and commissioning of UL listed hooters
28
-
-
Size 600x450x200mm
6
-
-
3.5x50 sqmm
14
-
-
212
-
-
24
-
-
Nahani trap 110x75mm
45
-
-
On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
24074
-
-
24
-
-
300
-
-
2D1F PLB Mobile pedestal - Size:- 400mm (W) x 450mm (D) x 660mm (H)
PreLaminated PLB based (E1 grade) 12/18 mm thick, Mobile pedestal unit with 3 drawers. Upper 2 box drawers + 1file drawer provided with Inner Metal Powder Coating Boxing sliding with soft closure Telescopic channels with rollers consists of 05no's Castors with PVC Depressed / Aluminum handles and a single lock. as per specifications and as per directed by Engineer in Charge.
10
-
-
290
-
-
5
-
-
10
-
-
Window sills, anchor blocks, string course, bends, copings, bed plates and like.
144
-
-
40 mm nominal bore
4
-
-
5mm thick
312
-
-
2
-
-
150mm diameter
11
-
-
The unit shall be as per the attached technical specification.
1
-
-
15
-
-
594
-
-
3.5x70 sqmm
7
-
-
SIDE UNIT top 30mm PF in duck nose profile , body 18mm laminated chip board with 3 draweer fixed on studs Size 1200Wx600Dx700H MOBILE DRAWER PEDESTAL with 1 drawer + 1 filling with PF top & body 18mm laminated chip board size : 450 x 575 x 560 Overall size 2850Wx1200Dx750H [Prelam Particle board (PLPB) & MDF Must be exterior grade Only],as per Specification & direction of Engineer-In-Charge.
5
-
-
8 Way VTPN DB
Comprising of following with ELCB:
Incoming:- One (1) No. 100 A FP MCCB(10KA)
Outgoing:Two (6) Nos. 63A TPN MCB(10KA)
4
-
-
8
-
-
Commercial-grade stationary bike with adjustable seat and handlebars
Specifications: 20
2
-
-
500
-
-
50
-
-
Made of B class heavy GI pipe with
powder coating, 114 od main pipe
4.5mm thick, other pipe 3mm thickness.as per Specification and as directed by Engineer in Charge.
2
-
-
1
-
-
80 mm dia. PN-1.6
2
-
-
18/20 Watt
465
-
-
50mm dia.
25
-
-
14286
-
-
1519
-
-
20
-
-
16722
-
-
Supplying, fabricating, installation, testing and commissioning free standing type MS powder coated cubicle three phase, 415 V power distribution/ control Type Tested Panel fabricated from 14 SWG MS sheet complete with required MS angle supports, tinned electrolytic Aluminium bus bar chamber with required rating, control switchgear and meter fixing plate, compartments for switch gear, meters and cables as per approved general arrangement plan, including 7 tank processes , approved shade powder coating, neoprene rubber gasket, internal wiring required foundation, earthing terminal, detachable gland plate, required size and rating rubber mating in front of each panel etc. as specified and shown on SLD complete with following
Incomer:
1250A, 4P, 415V,ACB, 50kA - 1 No. CT's of ratio 1250A- 1 Set
Communication modules for BMS compatibility.
2
-
-
138
-
-
22150
-
-
3.2 TR
11
-
-
293
-
-
750W Max., 600W RMS at 10% THD, 550W RMS at 5% THD, 500W RMS at 2% THD, 480W RMS at 1% THD Output Regulation ≤ 2 dB, no load to full load at 1kHz Input Channels 1 × 200mV/470kΩ (unbal.), 2 × 1V/50kΩ (bal.), 1 × 100V Input/50kΩ Frequency Response 50-15,000Hz ±3dB Signal to Noise Ratio 60dB Tone ControlsBass: ±10dB at 100Hz, Treble: ±10dB at 10kHz Outputs Loop through 1 × 200mV/600W, 2 ×1V/1kW Speaker Outputs 4Ω, 8Ω, 70V & 100V Power Supply AC: 220-240V 50/60Hz DC: 24V (2×12V Car Battery)
15
-
-
60
-
-
150mm diameter
300
-
-
In all types of soil
31430
-
-
310
-
-
Feeder Pillar:
INCOMER
1No. 63A FP MCCB(35 KA)
1No. 63A FP Contactor, AOM switch & Timers for 24 Hrs. setting
Metering & Indication
1 set of phase indicating lamps
BUS-BAR
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
12 Nos. 20A FP MCB & 15 NOS 6 A to 32 A MCB
20
-
-
10
-
-
With float glass panes of 6 mm thickness
1143
-
-
Single
104
-
-
2
-
-
Beams, lintels, cantilevers & walls
9014
-
-
mechanical means including cutting and transporting the earth to site of embankment/dumping area with lead upto 1000 metres, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections as per relevant clauses of section 300)
25840
-
-
10 watt {2 feet}
12
-
-
MAIN TABLE SIZE: 2400mm (W) x 900mm (D) x 750mm (H)
SUPPORT STORAGE: 900mm (W) x 450mm (D) x 680mm (H)
TABLE TOP: 25mm thick E1 grade PLPB table top with matching edgebanding with PVC Groomet provision of size:- 80 dia only anodized finish.Provision of keyboard tray and CPU spaces
UNDERSTRUCTURE: 25mm thick E1 grade pre-laminated particle board gable ends are considered for supporting table top.
MODESTY: 18mm Thick PLB modesy with 450mm (H) is considered.
WIRE MANAGEMENT: 1.2mm thk CRCA Powder coated wire tray with switch plate & PVC wire guard are considerd for wire management.
COMBO STORAGE:- Providing and fixing of Storage unit in laminate finish with 25mm thk Pre-laminated Top & 18mm thick Pre-laminate Sides and without shutters open shelf built in.
as per specifications and as per directed by Engineer in Charge.
5
-
-
158
-
-
2C X10sqmm
7
-
-
90336
-
-
20 mm nominal outer dia .Pipes.
90
-
-
6 X 2.5 sq. mm in 25mm conduit
450
-
-
6340
-
-
3 X 4 sq. mm in 25mm conduit
4300
-
-
Upto 1.5 m deep
236
-
-
Medium Point
135
-
-
Fabricated with GI (B-class) pipes & Tubes
Pipe Thickness -4mm
Length -1260 mm
Width -1010mm
Height -1525mm
Bearings: Deep groove/ self-aligning ball
bearings
Handle Bars: High Quality Grip Rubber
2
-
-
10
-
-
Soap Dispenser - Push Button SDR-WHT-DJ0010F capacity: 0.8L material: ABS finish: white/smoked
208
-
-
Pair of adjustable dumbbells with 5-50 kg range Specifications: Chrome-plated steel, ergonomic grip, 5-50 kg adjustable range as per Specification and as directed by Engineer in Charge.
2
-
-
3.5C X240 sqmm
100
-
-
4mm thick
480
-
-
10000
-
-
Capacity 9.0 ltrs
6
-
-
18/20 watt {4 feet}
36
-
-
480
-
-
80mm to 300mm dia (Heavy Class)
200
-
-
240 sqmm
1
-
-
4
-
-
80 to 300 mm dia
750
-
-
68
-
-
Made of B class heavy GI pipe with
powder coating, 114 od main pipe
4.5mm thick, other pipe 3mm thickness.as per Specification and as directed by Engineer in Charge.
2
-
-
1
-
-
1838
-
-
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
12816
-
-
seating size : 500 x 420 mm
Features:
Padded back and seat
Injection-moulded Polypropylene Shell
With Writing Tablet.
as per specifications and as per directed by Engineer in Charge.
50
-
-
10
-
-
10
-
-
micron) octoganal pole made of 3mm thick steel sheet having
window and flush cover with locking arrangement at suitable
height from base for cable termination block, pole suitably
reinforced with welded steel section at window cut section to
make the strength of pole unaffected, with following minimum
specifications including 3mm thick anchor plate, 4 nos 20mm
dia foundation bolts of EN8 grade. (designed for wind speed
upto 150km/hr)
7 metre high, dia 130mm at bottom and 70mm at top, base
plate size 220x220x12mm, foundation bolts 700mm long
60
-
-
20
-
-
32A with C series MCB
13
-
-
Supply, testing and commissioning of loop isolate module
12
-
-
2
-
-
HIGH BACK WITH S4 MECHANISM/ 2D ARMREST/ ALUMINIUM BASE / PU CASTORS
Backrest:-Seat to Backrest Height - 695mm, Backrest Height - 850mm, Backrest Width - 485mm.(with pp +foam, Upholstery Finish in Fabric and mesh back.)
Seat Rest:- Width Excluding Arms 450mm approx. x Depth including of Waterfall edge 490mm(Upholstery Finish in Fabric)MECHANISM: Density 58-61 Kg/m, Synchro 4 Position Mechanism , Back Tilt: 89 -109 degrees,
Height Adjustment : Gas Lift .
Base:-ALUMINIUM Die casted BASE fitted with 5Nos twin wheel 60mm dia castors. ARMRESTS :- 2D, Armrest Height from the seat - 180-260mm, Armrest Width excluding Armpads - 90mm, Arm pad length - 250mm, , Arm pad finish is PU, as per Specification and as directed by Engineer in Charge.
50
-
-
387
-
-
20
-
-
60
-
-
Cement Mortar 1:6 (1 cement : 6 coarse sand)
7969
-
-
10
-
-
Fabricated with GI (B-class) pipes &
Tubes
Maximum loading weight: 360 kg
Thickness: 4 mm
Length: 1550 mm
Width: 1550mm
Height: 1350mm as per Specification and as directed by Engineer in Charge.
2
-
-
manufacturer.
96
-
-
Medium Point
710
-
-
181.15
-
-
SS Grade 304
8973
-
-
1
-
-
6
-
-
standard design :
4
-
-
(Table:- 400-1)
Plant Mix Method with Mechanically crushed stone only(Construction of granular sub-base by
providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed
Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 ) Plant mix method (with Mechanically crushed stone only) for grading-III Material
9641.2
-
-
4
-
-
Part 1 - Complete maintenance for three year of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding, pruning, replacement of plants (if damaged), gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (including Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide , lawn mover and brush cutter & other T & P material/articles).
Part 2 - Maintenance and Cleaning of Water tank and water bodies
Maintenance and Cleaning of Water tank, and water bodies including disinfection once in three month for three year period all complete as per direction of engineer in charge.
Part 3 - Ma intenance of all the installed Irrigation and water supply items for three year period all complete as per direction of engineer in charge including the operational safety of the equipments.The contractor is responsible for any damages during course of operation. The piping and equipments should be in good working condition at the end of three year. All the necessary spares should be provided and be available along with a fitter throughout the maintenance period without any additional payment. The contractor should replace the damaged items without any additional payment during the course maintenance as detailed in special conditions of contract. as per direction of engineer in charge.
Part 4 - Maintenance of all the installed Electro mechanical works for three year period all complete as per direction of engineer in charge including the operational safety of the electro mechanical machaneries and equipments (installed from UGR source). The contractor is responsible for any damages during course of operation and Maintenance: . The electro mechanical machaneries and equipments should be in good working condition at the end of three year. All the necessary spares should be provided and available along with a fitter throughout the maintenance period without any additional payment. The contractor should replace the damaged fixtures , electro mechanical mechaneries and equipments without any additional payment as per direction of engineer in charge.
3.5
-
-
12000
-
-
Made of B class heavy GI pipe with
powder coating, 114 od main pipe 4.5mm
thick, other pipe 3mm thick in 2 station. as per Specification and as directed by Engineer in Charge.
2
-
-
INCOMER
1No. 4 Pole 100A TPN MCCB (35 KA)
1No. 100A FP Contactor, AOM switch & Timers for 24 Hrs. setting
Metering & Indication
1 set of phase indicating lamps
BUS-BAR
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
24 Nos. 32A SP MCB
GPRS MODULE FOR AUTOMATION
1
-
-
10
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
50 mm
45
-
-
16
-
-
Submersible pump 150mm dia. (with Bronze Impeller)up to 12 stages
5.0 H.P. Head Mt.15-24, Discharge LPM 930-420
2
-
-
36 watt {4 feet}
220
-
-
362
-
-
60
-
-
Made of GI (B-class) heavy pipe with
powder coating, 114 odi main pipe
4.5mm thick, other pipe 3mm thick, in 2
Station
2
-
-
362
-
-
Upto 1.5 m deep
3474
-
-
200
-
-
guarantee bond to be signed by contractor)
Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm.
8606
-
-
25mm
4200
-
-
2 TR
16
-
-
250x10mm
70
-
-
3.5C X400 sqmm
8
-
-
Weather shade, chhajja, Cornices and mouldings
132
-
-
2060
-
-
Motorized treadmill with incline and decline features
Specifications: 1200mm x 400mm running surface, 2.5 HP motor, 0-15% incline
as per Specification and as directed by Engineer in Charge.
2
-
-
158
-
-
2
-
-
32A with C series TP MCB
23
-
-
Granite stone black
200
-
-
Two coats on new surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
1168
-
-
2
-
-
12500
-
-
250A, 4P, 415V,MCCB , 35kA - 1 No. CT's of ratio 250/5A- 1 Set
Communication modules for BMS compatibility.
4
-
-
2CX1.0 SQ MM
400
-
-
500
-
-
The unit shall be as per the attached technical specification.
1
-
-
50 sq. mm
10
-
-
6
-
-
10
-
-
1. One side accessable closed metal rack with glass door, 4 nos. Door.
2. Construction & Material: Rigid Knock down construction. The whole body incliuding door shall be made up of CRCA Steel - Panels & Frame from 0.8 mm thick.
3. Configuration (Doors): 4 door. Door Features / Locking: Each Door shall be fitted with 10 Lever Cam lock with common key. Each Door shall have 3 mm Thk transparent glass for clear inside vision secured in a Metal Frame through rubber gasket·
4. Storage Shelving: Each compartment shall have storage shelf· Uniformly Distributed Load Capacity per each shelf shall be 80 Kg maximum. Contractor shall submit test certificates to confirm maximum UDL capacity of rack.
5. Finish: Epoxy Polyester Powder coated to the thickness of 50 microns (+/-10). The finish colour shall be as per NRDA.
6. Label holder: Label Holder shall be made from clear transparent Acrylic sheet and fixed at each loading levels for identification.
(Please also refer
10
-
-
600
-
-
319
-
-
Multi floor trap 110
45
-
-
Waste coupling 32mm Size Full Thread
with 80mm height
172
-
-
1
-
-
LEATHERETTE 1010L X 900W X 850H
Frame Construction- Kiln seasoned mixed meranti solid tropical hard wood.
Seats Webbing:- 3
20
-
-
1
-
-
35 mm. thick (single leaf)
596
-
-
Double
45
-
-
5
-
-
4000
-
-
125mmx75mm
225
-
-
8000
-
-
4 core 2.5 Sqmm
9000
-
-
8
-
-
5790
-
-
3.5C X400 sqmm
200
-
-
69
-
-
4 X 16 sq. mm
8
-
-
Access door cap
75 mm
45
-
-
wall angle ol’ ize24x24x0.40mm of length 30u0 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.Sscrews.The work shall be carried out as per specifications, drawing and as per directions of the Lngineer-in Charge. Ceiling height up 3.5 meter. from adjacent fioor level.Extra height to be paid separately.
8568
-
-
2
-
-
650
-
-
69
-
-
5
-
-
3
-
-
Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT ) Also available CQT-23069K Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible )
230
-
-
120
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
75 mm
45
-
-
per cum), form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required
60
-
-
5
-
-
1
-
-
1039
-
-
300mm
70
-
-
sizes heavy duty (continuous running) 1400 rpm exhaust fan in
existing opening in wall including earthing etc. complete as
required.
300 mm sweep
5
-
-
10
-
-
13
-
-
PVC pipe 75mm-8kg/cm2
1000
-
-
40
-
-
5/6 amps one way switch
140
-
-
723
-
-
Photoelectric type Smoke detectors
100
-
-
1653
-
-
2
-
-
Foundations, footings, base of columns and plinth beam in any shape and size.
28985
-
-
5
-
-
Size:1200mm(W) x 600mm(D) x 450mm(H)
Top: 12mmthk Temperd Glass Finish
Understructure:Base With SS metal Frame Legs/ solid wood polished as per specifications and as per directed by Engineer in Charge.
10
-
-
125x85x5.50 mm (Heavy Type)
526
-
-
mixed with water proofing compound conforming to IS. 2645 over the RCC slab including adjoining walls upto 300mm height.
ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) mixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) mixed with water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including
1880
-
-
5mm thick
145
-
-
guarantee bond to be signed by contractor)
Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the intervals of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
2634
-
-
5
-
-
70
-
-
Fabricated with GI (B-class) pipes & Tubes
Maximum loading weight: 120 kg
Thickness: 4 mm
Length: 1600 mm
Width: 530mm
Height: 700mm as per Specification and as directed by Engineer in Charge.
2
-
-
12 way, Single door
4
-
-
10
-
-
For 250 to 300 mm dia pipes
1
-
-
1285.2
-
-
Long Point
61
-
-
CRl-70 including all accessories support fitting etc as required
20
-
-
60 cm x 45 cm rectangular
5
-
-
Granite stone black
600
-
-
Supply, testing and commissioning of response indicator
28
-
-
150 mm dia. PN-1.6
5
-
-
Plain reducing Tee 110x75mm
45
-
-
In Cement Mortar 1:4 (1 cement : 4 fine sand)
31438
-
-
Made of B class heavy GI pipe with
powder coating, 114 odi main pipe
4.5mm thick, other pipe 3mm thick
2
-
-
6666
-
-
4x 10 sqmm
10.5
-
-
commissioning weather & dust proof IP based Fixed Lens true day / night Camera (IP67), 1/2.7
80
-
-
10
-
-
200
-
-
Fan Regulator Electronic, step type moving all round
225
-
-
80 mm dia. (Class -PN 1.0 rating)
4
-
-
3.5C X70 sqmm
2100
-
-
P trap 110mmx110mm long
45
-
-
Frame:
Material: Powder-coated steel, tubular metal frame, or hardwood (specify preferred material).
Thickness: Minimum [e.g., 1.5-2 mm] for metal or seasoned wood for wooden frames.
Finish: Anti-rust coating for metal or laminated/matte finish for wood.
Slats/Platform:
Material: Durable plywood/metal slats.
Thickness: Minimum [e.g., 12 mm] plywood or equivalent metal strips.
Load Capacity: Minimum [e.g., 120 kg per bed].
3. Design and Dimensions
Dimensions:
Length: 6.5 feet (198 cm).
Width: 3 feet (91 cm).
Height: [e.g., 18 inches (46 cm) from floor to bed surface].
Design:
Compact and lightweight for easy relocation.
Rounded edges or protective covers for safety.
Provision for under-bed storage clearance of at least [e.g., 12 inches].
Aesthetics:
Neutral colors (e.g., black, brown, or beige).
Smooth finish to match the hostel interior. as per Specification, design and as approved by Engineer-In-Charge.
200
-
-
220
-
-
120
-
-
25
-
-
Pillar Cock Auto Closing System with 65mm Extension Body
32
-
-
110 mm dia
900
-
-
6
-
-
8 way, Single door
4
-
-
50
-
-
24
-
-
9264.44
-
-
17
-
-
150mm dia.
290
-
-
cutback bitumen on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.85 kg/sqm using mechanical means as per clause 502 & 112) with bitumen emulsion (SS-1, grade confirming to IS:8887) @0.85 kg/sqm
23700
-
-
50
-
-
1
-
-
Size 800x800mm
1960
-
-
5
-
-
4C X10 sqmm
1400
-
-
HEIGHT ADJUSTABLE SPRINGLOADED SYSTEM
INTERNATIONAL STANDARD BOARD
Size: 180cm x 105cm, 25mm Transparent acrylic board
Standard pole extension 3.20 mtr, Made of heavy duty 6 inch Square pipe, base & structure Made of heavy retangular 4x2 & 5x2 inch pipe,20mm solid heavy
Duty dunking ring & nylon net, Pole padding on front & sides, Wheel size 6x2 inch pvc material, Portable battery boxes weight 600kg each side, best quality pu Spray paint.
4
-
-
120
-
-
32mm
260
-
-
69
-
-
6
-
-
1500
-
-
84
-
-
10
-
-
70
-
-
1500
-
-
Made of B class heavy GI pipe with
powder coating, 114 odi main pipe
4.5mm thick, other pipe 3mm thicknessas per Specification and as directed by Engineer in Charge.
2
-
-
Incomer:
250A, 4P, 415V,MCCB, 36kA - 1 No.
CT's of ratio 250/5A- 1 Set Communication modules for BMS compatibility.
2
-
-
Material : Color Coated Galvalume Sheet -ASTM A792; Std. Material Specification : Product : Galvalume Coil; SKU 1.20 MM BM x mm X 912mm , Grade: Substrate as per ASTM 792 M ; 340 Class 2. Coating: AZM150 , Paint Thickness: Top Coat. (25microns nominal including Primer) Bottom Coat (10microns nominal including Primer
Material Specification :
Color coated Galvalume sheet, BMT: 1.20 MM, APT: 1.25 MM, Tolerance : +/- 0.04 mm (Consumption @12.56 Kgs Per SQM), (Coil Width 912MM , Panel Width 620MM)
The work is inclusive of Anchor Bolts & Fasteners, Washers, with required fittings as per Proflex system, Epoxy - Epilux 610 Primer- Catalyse de poxy resin/ Zinc Phosphate, Rubber Paint - Bipson HB Zinc Phosphate Primer - Modified Alkyd medium pigmented with zinc Phosphate. inclusive of scaffolding, lifting fixing of the item at various levels for all heights and leads as per design and drawings all complete as per detailed technical specification and direction of Engineer-in-charge.
Note: Shop drawings for the elevation and fixing arrangement should be approved by Engineer in charge.Design and fixing of support systems shall be under the scope of contractor.Mode of Measurement: The roofing shall be measured for its curved surface area. The length and breadth shall be measured correct to a cm.The thickness shall not be less than that specified.
6620
-
-
59.999
-
-
2000
-
-
Size above 300x300mm
2800
-
-
3 pin 5/6 amp socket outlet
80
-
-
6
-
-
Upholstry/Frame: One piece ply in seat & back with foam & polyfill and leatherite upholstery with silver bidding all around
Seat size : 500 mm (w) x 480 mm (D)
Back size : 500 mm (w) x 580 mm (H)
Arms: Chrome finish arms with leatherite foam pad
Base : Chrome plated fixed base with PVC shoes, as per Specification and as directed by Engineer in Charge.
50
-
-
2
-
-
5
-
-
200 mm dia. PN-1.7
2
-
-
10
-
-
Made of B class heavy GI pipe with
powder coating, 114 odi main pipe
4.5mm thick, other pipe 3mm thick
2
-
-
11880
-
-
225 mm sweep
174
-
-
250
-
-
For VRV /VRF Module / Outdoor
4
-
-
20
-
-
2000
-
-
15
-
-
80mm dia.
282
-
-
5
-
-
between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.)
13000
-
-
100mm dia. pipe
1960
-
-
25
-
-
26
-
-
Submersible pump 150mm dia. (with Bronze Impeller)up to 12 stages
3.0 H.P. Head Mt.15-24, Discharge LPM 615-195
2
-
-
Olympic-style barbell with 7-foot length
Specifications:
Chrome-plated steel, 7-foot length, 50 kg capacity as per Specification and as directed by Engineer in Charge.
2
-
-
406
-
-
For 75 mm dia pipe
710
-
-
For 350 to 450 mm dia pipes
1
-
-
5
-
-
10
-
-
20mm
2100
-
-
9 metre high
65
-
-
160 mm dia pipe.
230
-
-
57
-
-
100mm diameter
17
-
-
32 mm dia
32
-
-
21
-
-
Thermo-Mechanically treated Bars FE 500D
1401624.172
-
-
20
-
-
Made of B class heavy GI pipe with
powder coating, 114 od main pipe 4.5mm
thick, other pipe 3mm thickness as per Specification and as directed by Engineer in Charge.
2
-
-
15
-
-
50 mm nominal outer dia .Pipes.
380
-
-
Wooden Sofa :- Fully upholstered sofa with good quality seaosed wood duly anti termite treated. In seat, good quality flat spring steel are used and are covered by
10
-
-
3.5C X 150 sqmm
1600
-
-
100 mm dia. PN-1.6
8
-
-
3½ X 50 sq. mm (32 mm)
4
-
-
a) HM shaft made of not more than 3 sections of suitable lengths with telescopic stressfit joints between sections without any circumpherencial welding, sheet thickness 4mm top, middle and bottom sections, nominal dia 600mm on bottom and 150 mm on top, base plate 32mm thick 840mm dia, PCD of foundation bolts 740mm.
b) Double drum winch for lowering & raising of lantern carriage on high mast with operatable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage.
c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box.
d) Top pulley assemble with weather proof cover.
e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & raising of lantern carriage.
f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm)
g) Hinged service door in base section
h) Base plate earthing terminal.
i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast.
j) Lightning conductor finial made of 25mm dia 300 mm long G.I.tube having single prong.
k) Anchor plate of size 840x840x6mm, tem-plates 3mm thick, GI foundation bolts 16 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc.
(RCC fooundation and luminaries will be paid separately)
6
-
-
Towel Ring Round with Round Flange
158
-
-
5
-
-
PVC pipe 110mm-6 kg/cm2
1000
-
-
8
-
-
flat iron support of size 25 X 6 mm on top, bottom and mid way and chain link mesh 50 x 50 mm aparture and 4 mm dia G.I. hard wire securing and screwing with 2mm dia G.I. wire, G.I. staples, G.I.U-nails or steel pins to the angle iron at every distance of 30 cms, by iron studs complete duly painted with one coats of red oxide and two coats of approved colour paint as per CSPDCL standards and direction of EIC.
160
-
-
75
-
-
120
-
-
2
-
-
11880
-
-
300/345 mm dia
700
-
-
Vertical and horizontal fins individually or forming box, louvers bands, almirah shelves and likes.
336
-
-
Set of weight plates (2.5-25 kg)
Specifications: Cast iron, chrome-plated, 2.5-25 kg range as per Specification and as directed by Engineer in Charge.
2
-
-
150x10 mm
60
-
-
300
-
-
1
-
-
4x16 sqmm
7
-
-
Jaquar ACN-1131N or Equivalent as approved by NRDA
Soap Dish Holder
208
-
-
7
-
-
10
-
-
300
-
-
2
-
-
2
-
-
20
-
-
10374
-
-
75 mm dia pipe
490
-
-
Single Towel Rail 600mm Long Also available
ACN-1111BNM Single Towel Rail 450mm Long
158
-
-
2 core 2.5 sqmm
100
-
-
On new work (two or more coats) including a base coat of white washing
551
-
-
1no. Panel for controlling incomer with VCB of 800 A ratings, CTs, PTs, digital Ammeter/ voltmeter/ Static Energy meter, O/C and E/F relay/other relays required for completeness, etc.
4 nos. Panel for controlling outgoing feeders with VCB of 630A rating, CTs, digital meter, Static Energy Meters, O/C and E/F relay, auxiliary relays, etc.
1nos. Panel for controlling capacitor bank with VCB of 400A, CTs, digital meter, capacitor protection relays, etc.
The unit shall be as per the attached technical specification.
1
-
-
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
1850
-
-
The Shade when lowering or raising, shall be automatically locked in position upon release of the ball chain by means of a built in friction lock. The END PLUG shall be molded of plastic with a steel location pin. The plug shall be inserted into the tube end. (Opposite to the Drive Unit).The SUPPORT BRACKETS shall be of coated steel & provided with covers and used in right hand or left hand positions differentiate d by the acceptance of the of the rectangular drive unit support or the round idler plug pin. as per specifications and as per directed by Engineer in Charge.6mm pitch to form an endless ball chain. It is used for raising or lowering action of the shades. The composition of FABRIC will be Polyester and PVC with no Volatile Organic Compounds recommended for clean room condition , having no bacterial / fungal emission and satisfying NFPA fire safety standard , shall be as per selection from approved ma ke range and design and shall be sized according to site requirement
. A bottom pocket shall be created in the fabric to incorporate the bottom rail. as per specifications and as per directed by Engineer in Charge.The ROLLER TUBE shall be of extruded aluminum with 38mm internal diameter & skin thickness of 1mm and shall incorporate a keyway integral with the tube to accommodate the spine. The outside diameter of the roller tube shall be 40mm.The BOTTOM RAIL shall be a stiffening element inserted into a bottom rod pocket. The material may be timber; PVC covered steel tube or VB Bottom rail. The BALLCHAIN shall be 2mm diameter cord with 4.5mm diameter acetyl balls molded co-axially to it on
243
-
-
10
-
-
225 mm width X 50 mm depth X 1.6 mm thick
50
-
-
2
-
-
60
-
-
125x2.5mm (heavy)
280
-
-
guarantee bond to be signed by contractor)
Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
2816
-
-
10
-
-
10
-
-
1200mm sweep
335
-
-
3 DRAWER PEDESTAL of size 480Wx640Dx600Hmm with top 18mm thk MDF board. Pedestal body 18mm PL MDF SIGNATURE SIDE UNIT size 1900Wx480Dx550H Double openable shutters on one side & single openable shutter. BACK UNIT 18mm thk. MDF size 500x500x1350.Back unit body is made of 18mm thk Pre Laminated MDF Size 2500Wx500Dx2100H [Prelam Particle board (PLPB) & MDF Must be exterior grade Only],as per Specification & direction of Engineer-In-Charge.
10
-
-
10
-
-
5MVA transformer mounting plinth foundation (size: 3.1mx3.1mx1.5m)
1
-
-
50 mm dia
51
-
-
300
-
-
20
-
-
1000
-
-
3200
-
-
4
-
-
25 mm nominal outer dia .Pipes.
40
-
-
1500
-
-
500W LED Flood Light
210
-
-
23
-
-
10
-
-
including making bore pit of minimum 150mm dia, providing and
laying approved make Earthing Electrode of Pipe-in-Pipe
technology as per IS 3043-1987 made of corrosion free G.I.
Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia
and filling with specified qty highly conductive compound around
pipe and above that with soft soil in bore pit complete and
providing masonry enclosure with cover plate having locking
arrangement and watering pipe etc. as required:
With 3 metre long GI Pipes and 50 kg back filling compound
6
-
-
Conference table as per detailed drawing attached. Light provision to be made inside the conference table dead area to maintain the electrical wiring etc. and two trap doors to be provided of approximate size 450 mm x 500 mm to access the dead area including Stainless Steel hardware. PU finish on top & melamine all other exposed surfaces. All internal unexposed areas to be finished with antitermite and fire retardant paint.ONLY TOP SURFACE IS MESURED FOR SIZE.
36
-
-
Capacity 22.5 Kg
6
-
-
50
-
-
Fabricated with GI (B-class) pipes & Tubes
Maximum loading weight: 240 kg
Thickness: 4 mm
Length: 2000 mm
Width: 730mm
Height: 1800mm as per Specification and as directed by Engineer in Charge.
2
-
-
Made of B class heavy GI pipe with
powder coating, 114 od main pipe 4.5mm
thick, other pipe 3mm thick in 2 station as per Specification and as directed by Engineer in Charge.
2
-
-
M-40 Grade, Cover
853
-
-
250 mmx 250 mm x 60 mm - 75 mm (3 compartment)
30
-
-
2
-
-
60
-
-
15 KVA/12KW UPS including battery bank with 30 Minutes Battery Backup And Rack As per requirement
2
-
-
3.5x150 sqmm
20
-
-
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
156
-
-
100mm dia
14
-
-
80mm dia. pipe
82
-
-
50
-
-
150
-
-
Serrated with central bulb (225mm wide, 8-11mm thick).
116
-
-
1.5m and upto3.0m deep
1654
-
-
Using Mechanical Paver (Providing, laying, spreading and compacting graded stone aggregate
to wet mix macadam specification including premixing the Material with water at OMC in
mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.)as per clause 406.
4904
-
-
4
-
-
Hand Dryer - Smartflow HDR-WHT-M04A material: ABS
finish: white
20
-
-
For 100 mm dia pipe
710
-
-
25mm dia.
10
-
-
5
-
-
Fabricated with GI (B-class) pipes &
Tubes
Maximum loading weight: 240 kg
Thickness: 4 mm
Length: 2100 mm
Width: 750mm
Height: 2150mm as per Specification and as directed by Engineer in Charge.
2
-
-
331
-
-
70
-
-
3
-
-
LEATHERETTE 2010L X 900W X 850H
Frame Construction- Kiln seasoned mixed meranti solid tropical hard wood.
Seats Webbing:- 3
10
-
-
A.Construction: Rigid knock down construction. The load bearing member should be from ‘Boltless-T’ shaped CRCA 1.0mm thick Rolled sections of size 50 x 40 mm with slots at a pitch of 20 mm to engage clips which hooks with shelves. The front visible side of the section should be plain (without slots). Shelves should be held to the vertical members by means of removable clips and no nut/bolt/ washers should be used.
B.Material: -
1. Racks- ‘Boltless-T’ shaped CRCA 1.0mm thick Rolled sections of size 50 x 40 mm & Skirting shall be of approved make and finish.
2. Side panels shall be inserted between the ‘T’ sections and shall be of 25mm thick pre laminated particle board (WOOD BASED ONLY) of exterior grade as per IS 12823:1990 (IS 3087: 2005). All exposed and balancing laminates should be of 0.6-0.8 mm thick. All lipping should be of PVC edging of 2 mm thickness on all edges. Side panels shall form as covering of racks from the sides and shall not be a load bearing member. 3. Finish: Color Finish of laminate shall be as per the approval of NRDA. Metal panels shall be epoxy polyester powder coated to the thickness of 50 microns (+/- 10 mm). The color finish of metal panel shall be per as NRDA approval.4. Number of racks: There shall be bottom plus four fixed CRCA 0.8mm thick racks on each side (Total 10 loading levels). For stiffening of the racks beading shall be provided. Uniformly distributed load capacity per each full shelf shall be 80 kg maximum. Contractor shall submit test certificates to confirm maximum UDL; Capacity of the rack.
5. Rack back stiffener: At the rear side of the racks back stiffener shall be provided. These shall support books on the rear side & also act as the driver between front & rear books in upper two compartments.
6. Label holder: Label Holder shall be made from clear transparent acrylic sheet and fixed at each loading levels for identification.
(Please also refer
10
-
-
6
-
-
20A with C series TP MCB
13
-
-
10
-
-
The unit shall be as per the attached technical specification.
1
-
-
100mm dia
15
-
-
45148
-
-
adaptor with ESE Air Terminal & various
accessories( fasner , guy wire , ring fasner, huk
etc)
Length – 5mtr
Pipe – Jindal , Dia. -50mm
Thickness – 3.4mm
Base plate – (300x300x6)mm
2
-
-
clause 602 & 112.
1394
-
-
125 mm
140
-
-
120
-
-
Alternator: rated at 250 KVA, 415 volts at 1500 RPM,suitable for 50 Hz 3-Phase system, AC Supply with 0.8 lagging power factor
AMF Panel :Cubical, compartmentalized, AMF panel board with all suitable size power and control contactors, switches,meters and other accessories, internal wiring, connection,inter-connection etc. for trouble free smooth functioning of DG Set with power pack of 12V/24 DC as required.
Base Plate : Common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting etc. as required
Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of engine and alternator, extraction, discharging hot air in to the atmosphere as per pecifications
Fuel -level information :Fuel tank shall be install with remote sensing unit for fuel tank level
work shall be included with all civil worl like foundation ,shed of D.G set & interconnection between D.G and Main LT panel.
2 year warranty and Quartly visit the D.G set for 2 year ,
2
-
-
10
-
-
Supply of factory insulated Pair of Refrigerant Y-joints for various pipe sizes and headers for Indoor units
20
-
-
10
-
-
Made of B class heavy GI pipe with
powder coating, 114 od main pipe 4.5mm
thick, other pipe 3mm thick in 2 station as per Specification and as directed by Engineer in Charge.
2
-
-
M-20 (using minimum cement 390 kg/cum concrete)
1850
-
-
5359
-
-
3C X 240 sqmm
900
-
-
PVC pipe 90mm-10 kg/cm2
500
-
-
125mm
1028
-
-
40 amps
30
-
-
12
-
-
23690
-
-
1
-
-
1.5m and upto 3.0m deep
166
-
-
Thickness=3mm, width=1000mm, length=10m colour coding=Black or blue , Antiskid Rough Surface=Dimond plate, matting class=C, Max use voltage ac (rms ) 33 kV & Dc (rms ) 240 V , Di electric strength AC (rms ) 65 kV, Proof voltage AC (rms ) 36 kV
15
-
-
5
-
-
Operation number input keys with LED display. Input MIC: 600Ω,10mV, unbalanced, Line:10kΩ,775mV, unbalanced
Output Balanced Frequency Response MIC:100Hz~15KHz; Line: 30Hz~18KHz S/N Ratio MIC input: 60dB Line input: 80dB
2
-
-
150mm dia
6
-
-
Extra Long Point II
130
-
-
4
-
-
Cafeteria chair having L-type moulded laminated ply in seat & back with cross supoort of square pipe. The understructure & frame material is made up of 25mm dia round pipe with chrome finish. Noiseless PVC shoe is given in below the frame, as per Specification and as directed by Engineer in Charge.
100
-
-
Jaquar FLR-5047N or Equivalent as approved by NRDA
Bib Cock (Straight Line Model) With Wall Flange
245
-
-
Hedges like Alife, Dorenta, Tikoma etc
25000
-
-
3120
-
-
80mm diameter
2
-
-
32 mm dia
186
-
-
LEATHERETTE 1600L X 900W X 850H
Frame Construction- Kiln seasoned mixed meranti solid tropical hard wood.
Seats Webbing:- 3
10
-
-
10000
-
-
250A, 4P, 415V,MCCB , 35kA - 1 No. CT's of ratio 250/5A- 1 Set
Communication modules for BMS compatibility.
3
-
-
4C X16 sqmm
5225
-
-
The unit shall be as per the attached technical specification.
1
-
-
3.5C X50 sqmm
1750
-
-
11880
-
-
50
-
-
With 20x20 mm square bar
17
-
-
Toilet Roll Holder with Flap
214
-
-
70
-
-
concrete foundation having grouted bolts and nuts, aligning in
true vertical position as required :
7 metre high
60
-
-
Supplying/Receiving, Installation, Testing and Commissioning of Powder coated,
14 SWG CRCA sheet steel enclosed 33 KV H.T. Metering Panel complete with the
following:
1set of 33/ 3KV / 110/ 3 Volt, 100 VA burden & accuracy class 0.5, single phase
construction, dry type cast resin PT.
3 Nos. of dual core 100/5-5A, 15 VA burden, accuracy class 0.5, 33 KV cast resin
CTs .The short circuit ratio should be 25KA for 1 sec
One Set of Phase Indicating Lamps.
2 Sets of HRC fuses with fuse base (H.T. Fuse - 1A & LT fuse 2-6A).
2 Nos. indoor cable end box for suitable for 3C x 300 sq.mm. 33 KV(E), aluminium
conductor XLPE Ar. cable (Incoming & Outgoing cable).
Metering cubical shall be as per the Standard of CSPDCL.
1
-
-
500 KVA
2
-
-
150mm dia
6
-
-
a) HM shaft made of not more than 3 sections of suitable lengths with telescopic stressfit joints between sections without any circumpherencial welding, sheet thickness 4mm top, middle and bottom sections, nominal dia 600mm on bottom and 150 mm on top, base plate 32mm thick 840mm dia, PCD of foundation bolts 740mm.
b) Double drum winch for lowering & raising of lantern carriage on high mast with operatable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage.
c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box.
d) Top pulley assemble with weather proof cover.
e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & raising of lantern carriage.
f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm)
g) Hinged service door in base section
h) Base plate earthing terminal.
i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast.
j) Lightning conductor finial made of 25mm dia 300 mm long G.I.tube having single prong.
k) Anchor plate of size 840x840x6mm, tem-plates 3mm thick, GI foundation bolts 16 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc.
(RCC fooundation and luminaries will be paid separately)
6
-
-
1185
-
-
Capacity 4 kg
26
-
-
Low-impact elliptical trainer with adjustable resistance
Specifications: 14
2
-
-
2C X6 sqmm
5
-
-
10
-
-
PVC pipe 63mm-8kg/cm2
500
-
-
( Payment of the work shall be made only after spreading / utilization of the same)
500
-
-
1
-
-
Columns, Pillars, Piers and likes- rectangular or square in shape
9373
-
-
300x16x5mm
518
-
-
3 X 1.5 sq. mm in 20mm conduit
10400
-
-
(c) Bus Bar Chamber (Havells)
2
-
-
80 mm dia PN-1.6
2
-
-
Extra for brick work in superstructure: Above plinth and upto floor five level.
6912
-
-
6
-
-
853
-
-
80mm dia PN-1.6
2
-
-
The GI strut system includes GI Cross channel having thickness 0.45mm, length 3600mm, knurled web 40mm, depth l0mm and equal flanges 15mm is fastened vertically/horizontally at every 600mm centers. Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth l8rom and flanges of 7mm with suitable edge and centre brackets fa then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers, Contractor to Provide expansion joints of 3mm at every Snits bothways.Material shall be approved make with patterns and design.
200
-
-
3200
-
-
3
-
-
Note : For UPVC frame, sash and mullion extruded profiles minus 5% tolearance in dimension i.e. in depth & width of profile shall be acceptable.
(Ammendment No. 65011/151 Date 19/07/2017)
Casement window single panel with SS friction hinges (300 x 19 x 1.9mm) made of (small servies) frame 47 x 50mm & sash 47 x 68 mm both having wall thickness of 1.9 + 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of Window upto 0.75 sqm.)
36
-
-
3000
-
-
300 mm dia.
432
-
-
9
-
-
ISI marked O-PVC (Oriented uplasticized polyvinyl chloride) ring fit type pipe having orientation class 500 (IS 16647) with integral homogeneous spigot having elastomeric seeling ring made of EPDM rubber (one per pipe) including testing of joint, cost of jointing materials etc. complete in all respect. Presure Rating as
110mm diameter
740
-
-
5
-
-
60 cm Circular
5
-
-
150mm dia-Medium
100
-
-
INCOMER
63A, 4P, 415V, MCCB, 36kA - 1No. CT's of ratio 63/5 Amps - 1 Set Multifunctional meter (Type M) - 1no
BUS-BAR
1 Set of 100A 4P Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
32 amps MCB TP ,440 volts-10 nos
6 to 32A SP MCB C series - 10 nos 10kA as out going feeder
4
-
-
800
-
-
Short Point
54
-
-
PVC pipe 160mm-6 kg/cm3
1000
-
-
Provision also for connecting an additional
microphone and doing zonal paging from the
Paging Selector itself. These announcements will
have priority over announcements made from a
Remote Paging Microphone. 2 channel amplifier inputs (Channel A for BGM Amplifier and Channel B for Paging Amplifier). Input MIC1,2:600Ω,5mV,unbalanced Line1,2:10KΩ,775mV unbalanced Frequency Response MIC:100Hz~15KHz; Line: 30Hz~18KHz, S/N Ratio MIC input: 60dB Line input: 80dB, Controls MIC1, 2 VOL Controls, 10 channel selectors, chime button, power switch
Power Supply 230V/50Hz, Communication Protocol RS422
Communication Input & Speed RJ45, Speed : 4800bps
2
-
-
Rectangular shape 600x450mm internal dimensions
4
-
-
514
-
-
Made of B class heavy GI pipe with
powder coating, 114 od main pipe 4.5mm
thick, other pipe 3mm thickness.as per Specification and as directed by Engineer in Charge.
2
-
-
4 mm thickness
262
-
-
12 mm thick for door/partition
57.6
-
-
8
-
-
69
-
-
Long Point
135
-
-
1300
-
-
50
-
-
225 mm width X 50 mm depth X 1.6 mm thickness
1000
-
-
Wooden Sofa :- Fully upholstered sofa with good quality seaosed wood duly anti termite treated. In seat, good quality flat spring steel are used and are covered by
10
-
-
10
-
-
bitumen emulsion RS-1, grade confirming to IS:8887 using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom) as per clause 503 & 112.
on Bituminous surfaces @ 0.25 kg per sqm
23700
-
-
200
-
-
2
-
-
4x25 sqmm
10.5
-
-
2
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
110 mm
45
-
-
2
-
-
Granite stone black
890
-
-
25663
-
-
10
-
-
Short Point
468
-
-
1
-
-
1
-
-
200mm diameter
2
-
-
TOURNAMENT MODEL,
Base made of heavy 180mm Square pipe with solid 80kg
Weight each side and vertical Member made of heavy 50mm Square pipe, adjustable rachid With heavy duty nylon net, fine Quality spray pu paint.
4
-
-
160
-
-
240 sqmm
3
-
-
Hand Shower (Health Faucet) with 8mm Dia,
1.2 Meter Long Flexible Tube & Wall Hook
230
-
-
Frame:
Material: Powder-coated steel/aluminum alloy for durability and corrosion resistance.
Thickness: Minimum [e.g., 1.5 mm] for structural stability.
Seat and Backrest:
Material: High-density polyurethane or molded plastic.
Upholstery: Synthetic leather or weather-resistant fabric, UV stabilized.
Cushioning: High-density foam, minimum thickness of [e.g., 50 mm].
Armrests: Ergonomically designed with the same finish as the seat.
Legs/Base: Non-slip rubber or PVC caps to prevent movement and floor damage.
3. Design and Dimensions
Dimensions (approximate):
Seat Height: [e.g., 400-450 mm].
Seat Width: [e.g., 450-500 mm per chair].
Total Height: [e.g., 900 mm].
Ergonomics: Comfortable seating angle and proper lumbar support.
Aesthetics: Colors to match [Specify color scheme, e.g., team colors or neutral tones].
Portability: Lightweight but sturdy construction for ease of movement.
4. Performance Requirements
Weather-resistant: Able to withstand outdoor conditions (sunlight, rain, humidity).
Load Capacity: Capable of supporting a minimum of [e.g., 150 kg].
Anti-corrosion: Tested for resistance to rust and corrosion.
5. Certification
The material and construction must comply with [Specify relevant standards, e.g., ISO, BIS].
Provide certifications for fire-retardant properties if required.
6. Quality Assurance
Manufacturer's warranty documentation to be provided.
Supplier to submit a sample unit for approval prior to full delivery.
Third-party inspection may be conducted for quality assurance.as per Specification and as directed by Engineer in Charge.
5
-
-
36 watt, size 600 x 600mm
330
-
-
32 mm nominal outer dia .Pipes.
220
-
-
Carpet grass (well developed)
500
-
-
2
-
-
500
-
-
Panel Width = 2500mm
Panel Height = 1560 mm
Panel Wire Dia = 5 mm in Pre-Galvanised up to min. 70 GSM
Tolerances are in accordance with EN 10218-2.
Tensile Strength of Vertical & Horizontal wires: Minimum 400N/mm2
Panel Mesh Size = 200 mm x 50 mm
Panel V Bends = 03 Nos.
Panel Finish = Dual PPC Powder Coated up to min. 140 Microns in RAL 6005 (GREEN) or as approved
Post Type = H Profiled, 70 mm x 40 mm x 2 mm Thick.
Post Height = 1600 mm.
Post Mounted on Pre-welded Universal Base Plate of Size = 175 mm x 80 mm x 10 mm Thick.
Post Anchored by M12 x 150 Expanded Anchor Bolts.
Post-Joineries of Mushroom Head, High-Security, Tamper Proof Nuts & Bolts in SS304
Post Finish = Pre-Galvanised up to min 150 GSM + Dual PPC Powder Coated up to min. 140 Microns in RAL 6005 (GREEN) or as approved
The entire System is 1000 Hours of Salt Spray Tested to withstand extreme climate conditions
492
-
-
1
-
-
Incomer:
100A, 4P, 415V,MCCB, 36kA - 1 No.
CT's of ratio 100/5A- 1 Set Communication modules for BMS compatibility.
16
-
-
Under Counter Basin
Size (mm) 550x360x120
172
-
-
12
-
-
Inflatable exercise balls (55-65 cm diameter)
Specifications: Durable PVC, 55-65 cm diameter, anti-burst design as per Specification and as directed by Engineer in Charge.
2
-
-
System shall also have 120 mm high powder coated standalone panel legs to give the system an elevated look. Worksurface - out of 25 mm thk prelam particle board with flat pvc lipping edge banding of size 1200 mm w x 600 mm d. Pedestal - Nova pedestal flat metal front, full ht free standing central locking of size 390 mm w x 435 mm d x 646 mm ht 3dr = 2box+1file. CPU trolley - with castors KBPT with mousetray - metal. Note: All partitions and side panels have levelling screws for adjustment in case of Uneven floor to take care of +/- 40 mm of uneven flooring [Prelam Particle board (PLPB) & MDF Must be exterior grade Only],as per Specification & direction of Engineer-In-Charge.
50
-
-
3.5x240sqmm
8
-
-
2
-
-
6
-
-
Medium Point
65
-
-
4
-
-
10
-
-
50 mm dia pipe
240
-
-
250mm
70
-
-
12
-
-
20
-
-
High Back Revolving ChairUpholstry/Frame: One piece ply in seat & back with foam & polyfill and leatherite upholstery and wooden bidding all around
Seat size : 500 mm (w) x 500 mm (D)
Back size : 500 mm (w) x 720 mm (H)
Arms: Wooden arms with melamine finish
Standard Mechanism :Torsion bar Mechanism
Height Adjustment : Gas Lift
Base : Wooden base with twin wheel castors, as per Specification and as directed by Engineer in Charge.
10
-
-
Stair cases of all types excluding spiral and folded plate type, including risers and landings
980
-
-
12220
-
-
Fabricating pipes from steel plates (all thickness)
5 to 8 mm
0.2
-
-
100mm dia.
2060
-
-
Pull Station Type Manual Call Points (MCP)
15
-
-
10
-
-
STANDARD REGULATION TOP SIZE:
2740 x 1525 x 760mm, top Thickness 25mm laminated
High quality, frame size 75mm X 25mm, leg size: 100mm x 50mm, Wheel size 125mm x 25mm, 4
Wheels with lock, 4 wheels Without lock, double child
Safety lock system, foldable And movable anywhere,
Indoor, complete powder Coated structure, with net
And post cardboard packing, Weight: 155kg. Approx
4
-
-
Urinal with Fixing Accessories Set.
Size: 375 x 315 x 620
46
-
-
10
-
-
300
-
-
30
-
-
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
2016
-
-
2C X10 sqmm
875
-
-
Cover and frame H D - 20
2
-
-
250 x10 mm
514
-
-
60 cm equilateral triangle
5
-
-
3 X 2.5 sq. mm in 20mm conduit
11700
-
-
5
-
-
In rows 5 cm apart in either direction.
7000
-
-
5
-
-
10
-
-
187
-
-
Granite stone black
569
-
-
5
-
-
PVC pipe 200mm-6 kg/cm4
1000
-
-
4
-
-
71
-
-
Supply, testing and commissioning of control module
12
-
-
Tee/ Tee with door/ Bend 45°/ Bend 90°
150 mm
45
-
-
Supply of factory insulated Pair of Refrigerant T-joints for various pipe sizes and headers For Outdoor units
12
-
-
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.
543.6
-
-
Max 200 Mbps incoming & outgoing bandwidth, Smart H.265/ H.264 codec decoding, Upto 8 MP resolution preview and playback, Frame Rate: 1-15 FPS(8 MP); 1-25/30 fps for rest of Resolutions; Support 2 SATA HDDs up to 12 TB each, 2 USB (1 USB3.0,1 USB2.0), 1HDMI /1 VGA simultaneous video output , Two way talk 1Channel Input, 1Channel Output RCA, 1RJ-45port (10/100/1000Mbps),
5
-
-
20
-
-
5
-
-
948
-
-
1
-
-
8 SWG wires
300
-
-
Long Point
760
-
-
100mm diameter
440
-
-
Manufacturer should be from Europe (No Asian / Turkey) and his products should have been used for European Championships. Surface average technical standards should include 0.86 MPA/mm Tensile Strength, 77% Elongation at Break, 41 % Force Reduction at 39.60C, 1.8 mm Vertical Deformation at 39.60C, should be Spike resistance, Average friction value of system should be 65. Wear coat to be applied “wet-in-wet” and homogeneous. EPDM granules are to be broadcasted into wet polyurethane wear coat. Supply rate should be 3.6 kg/m². Excess EPDM is to be removed after polyurethane wear coat is cured (this excess quantity is returnable to supplier). EPDM content in wearing surface after removal of excess granules should be 2.8 kg/m² net. Physical properties of applied system in compliance with test report . Approved Make : Ebaco-BSG,Regupol, Klefer, EPIQ
16052
-
-
5-Loop, each loop 252
4
-
-
Double
45
-
-
1145x510 mm bowl size 560x410x241 mm
8
-
-
36.6542
-
-
aluminium ferule/ lugs to following size 1.1 KV grade power
cable core / lead, pressed with high pressure cramping tool
including connection to switch gear/ MCCB etc as required
16 sq.mm
880
-
-
Supply, Erection, Testing and Commissioning of Indoor type UPS OUTGOING VDB/PANEL, Wall mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalised, cable entry shall be in both top and bottom, modular type IP 42 Protection with powder coated panel as specification below. single Meters and it CT should connected in common main bus. All MCB should be 'D' curve.
Incomer:
1No -100A TP+2N 26kA MCCB (Neutral should be 200% of the Phase Current)
1Sets of Current transformer rated 63/5A, 10VA/CI 1.0 for metering at common bus.
1No � Digital Multi data Meter with RS 485 (suitable to measure harmonics) at common bus.
1 Sets � LED type RYB indication lamps with control fuses
Outgoing:
8Nos - 40A TP+2N MCB 16kA
100A TP+2N Copper Bus Bar and Associated Accessories as required. (Neutral should be 200% of the Phase Current)
Incoming and outgoing cables shall be of Top& Bottom entry.
2
-
-
300x16 mm
4
-
-
200W LED Flood Light
230
-
-
Holes 60 cm dia, and 60 cm deep.
500
-
-
sizes fancy exhaust fan having built in lovers in existing opening
in wall including earthing etc. complete as required.
300 mm sweep
8
-
-
Satin synthetic enamel paint (top most approved branded quality
1626
-
-
100
-
-
250x16mm
120
-
-
With float glass panes of 8 mm thickness
216
-
-
On new work (two or more coats)
46529
-
-
PVC pipe 40mm-6 kg/cm2
100
-
-
170/200 mm dia.
2099.5
-
-
255
-
-
60watt ( +/- 5 % W)
60
-
-
Size 600 mm x 600 mm x 500 mm
69
-
-
Multi-Sensor combined (Photo + Thermal) detectors
65
-
-
ISI marked O-PVC (Oriented uplasticized polyvinyl chloride) ring fit type pipe having orientation class 500 (IS 16647) with integral homogeneous spigot having elastomeric seeling ring made of EPDM rubber (one per pipe) including testing of joint, cost of jointing materials etc. complete in all respect. Presure Rating as
160mm diameter
300
-
-
Fabricated with GI (B-class) pipes & Tubes
Maximum loading weight: 240 kg
Thickness: 4 mm
Length: 1020 mm
Width: 860mm
Height: 1300mm
2
-
-
150mm dia. pipe
290
-
-
25
-
-
3.5C X25 sqmm
1050
-
-
90 cm high octagon
5
-
-
9 metre high, dia 155mm at bottom and 90mm at top, base plate size 260x260x16mm, foundation bolts 750mm long
65
-
-
Single rebate 100mm x 50mm size, 1.6mm thick sheet.
1095
-
-
Cement Mortar 1:4 (1 cement : 4 coarse sand)
22
-
-
200
-
-
PVC pipe 110mm-10 kg/cm2
500
-
-
wall hung WC with PP seat cover, Hinges accessiories set. Size: 360X545X365
FLS-WHT-5951
230
-
-