Postgraduate Institute Of Medical And Education And Research Tender
View complete overview of Chandigarh PGIMER Tender
Postgraduate Institute Of Medical And Education And Research - PGIMER Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Jan 2025
Closing Date23 Jan 2025
Tender Amount₹ 17,99,152
Costs
EMD
₹ 35,980Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PGIME_842797_1Tender No
PGI/Engg/RAC/2024/271Tender Authority
Postgraduate Institute Of Medical And Education And Research ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Neutral link 1 No.
-
-
-
... More
Neutral link 3 No.
-
-
-
... More
SITC of perforated pre painted M.S. Cable tray with perforation not more than 17.5% in convenient sections ,joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts, painting suspenders etc. As required.
-
-
-
... More
DX Type Air Handling unit with 100% Fresh Air
-
-
-
... More
150 mm width x 50mm depth x 1.6 mm thickness.
15
604
9060
... More
Start stop push button 6 No.
-
-
-
... More
For 1st Year(After Defect liability period)
1
70093
70093
... More
Single phase preventer relay 2 No.
-
-
-
... More
Supply installation testing and commissioning of free floor / wall mounted electric panel made of 2mm thick, 400mm deep steel sheet duly powder coated complete with voltmeter & ammeter, indicating lights, selector switch incoming /outgoing isolator, single phase preventer complete with Al bus bar 100 amp.,Time delay relay for delayed automatic restart of motor, solid copper interconnection as per specification as under.
1
110016
110016.33
... More
Project value (1201852 @ 5% )60092.6 + 10000
-
-
-
... More
B phase indicating lamp 240 V AC 1 No.
-
-
-
... More
Fire damper
1
10659
10659
... More
28.6 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
15
1108
16620
... More
11.0 TR outdoor units for AHU 2600 cfm (01Working And 01 Standby) with Eco Friendly Refrigerant R410
2
213434
426868.34
... More
PLA relay 3 No.
-
-
-
... More
For 2nd Year
1
73597
73597.65
... More
Single phase preventor relay 3 No
-
-
-
... More
Supply installation testing and commissioning of PVC insulated armored copper cabling 4 core 6 sq mm from electrical panel to AHU/Out door units alongwith 6 SWG GI double earthing clamped on surface etc. complete in all respect as per specification and direction of engineer incharge
25
682
17056
... More
Dismantling of existing AHU, Electrical panel, Outer door units, etc and cleaning & removing of scrap from the site
1
10000
10000
... More
Add on block 2 No + 2 NC 6 No.
-
-
-
... More
16 A TP 10 KA MCB curve type 3 No.
-
-
-
... More
Minor civil work (making good foundations and if any)
1
3000
3000
... More
Start stop push button 4 No
-
-
-
... More
Add on block 2 No + 2 NC 3 No.
-
-
-
... More
supply installation, testing and commissioning of double skin floor mounted AHU (canopy) having pre-coated/pre plasticized GI sheet of 0.8 mm on outside & 0.8mm thick plain GI sheet inside. with backward curved fan ,cooling coils dx type , twin circuit with combination of 6 row + 6 row having minimum 500mm gap between them , 125 mm external static complete with Bird mesh and louver, filter section with 50 mm thick washable synthetic pre filters having efficiency 90% down to 10 micron , fine filters having efficiency 99% down to 5 micron and Hepa filters with efficiency 99.99% down to 0.3 micron., with drive package with tefc drive motor suitable for 415 +-15 volt, 50 hz 3 phase ac supply , twin circuit , two distributer to be connected with 11.0 TR two nos air cooled condensing units, including gas charging,It must be with thermal break profile.Inbuild digital Magnehelic gauges across the Hepa Filter section
1
470116
470116.85
... More
100 A TPN aluminum main bus bar load wise sub feeder bus bar colour coated heat shrink bus bar sleave nut bolt washer hardware etc
-
-
-
... More
Supply installation testing and commissioning of 1.1 KV grade PVC insulated armored control copper cabling 4 core 2.5 sq mm from condensing unit to AHU complete in all respect as per specification and direction of engineer in charge.
25
231
5776.25
... More
WIRING & ACCESSORIES
-
-
-
... More
0.63 mm
30
1058
31740
... More
FOR HEAT BANK (12 KW) -1 No.
-
-
-
... More
A/M selector switch 2 No.
-
-
-
... More
P/F rigid PVC drain piping (32 mm dia) complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation.
10
214
2141
... More
Supply, installation, testing and commissioning including vaccumumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for DX Coil system complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class- O tubular insulation/ with Classs-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required.
-
-
-
... More
The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor & belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers
-
-
-
... More
Actuator
1
9948
9948
... More
50 A TP 10 KA MCB curve type 2No
-
-
-
... More
Auxiliary contactor 2 No +2 NC 2 No.
-
-
-
... More
0.80 mm
20
1229
24580
... More
CTs 100 / 5 A CL-1 15 VA resin cast / nylon casing 3 No
-
-
-
... More
14 - 23 A THERMAL OVERLOAD RELAY 2 No
-
-
-
... More
PLA relay 6 No.
-
-
-
... More
2600 CFM /125 mm wg St. Press.(100% Fresh Air)
-
-
-
... More
P/F Flanged Type Heater Batteries for winter heating comprising of 12KW kw Consisting of MCB TPN of suitable rating as incomer, an AC duty TP magnetic cotantactor,thyristor modules with CSR fuse for stepless operation 0-100% variable,ON indication light ,TRIP indication ligh,Capillary type primary thermostat for high temp trip,Fixed type secondary bimetallic cut-out,required ratings element made out of SS-304 tubular type without fins.Control terminals for interlocking with AHU and field controls(Temperature Controller & humidistat etc).Airflow switch with time delay feature & having arrangement for on/off in stages with thermostat, geyser stat contactor, interconnected wiring control panel etc.
1
79054
79054.89
... More
ENCLOSURE & ACCESSORIES
-
-
-
... More
Power & control wiring will be ( 1st 1100 V) flame retardant low smoke PVC single core copper wire copper luggs PVC sleeve ferrules numbers hardware & labour etc.
-
-
-
... More
6 A SP control MCB 3 No.
-
-
-
... More
On off indicating lamp 4 No.
-
-
-
... More
On off indicating lamp 6 No.
-
-
-
... More
For 3rd Year
1
77277
77277.53
... More
Electrical control panel - 3
-
-
-
... More
MAIN INCOMER
-
-
-
... More
OUTGOING
-
-
-
... More
15 KW DOL STR.- FOR AIR CONDITONING UNIT- 2 No.
-
-
-
... More
Extended rotary handle 1 No.
-
-
-
... More
32 A TP power contactor 6 No
-
-
-
... More
3.7 LW DOL STR- 3 NOS.
-
-
-
... More
Supplying & fixing of following thickness duly laminated aluminum foil of mat finish closed cell nitrile rubber (class "0" ) insulation on duct after applying two coats of cold setting adhesive (CPRX Compound). The joints shall sealed with 50 mm wide & 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required (Having minimum 45kg/Cum density)
-
-
-
... More
15.9 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15
588
8820
... More
Add GST @ 6.33 %
1
84068
84068.26
... More
Digital voltmeter with VSS 1 No.
-
-
-
... More
19mm
60
754
45240
... More
For 5th Year
1
85198
85198.48
... More
Buy back of AHU, Electrical panel, outdoor units etc
1
40000
-40000
... More
SITC of fire damper for supply air ducts/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications and control switch compatable with existing fire alarm system
-
-
-
... More
Supply installation testing and commissioning of PVC insulated armored copper cabling 4 core 10 sq mm from electrical panel to AHU/Out door units alongwith 6 SWG GI double earthing clamped on surface etc. complete in all respect as per specification and direction of engineer incharge.
25
1034
25867.25
... More
Digital ammeter with ASS 1 No
-
-
-
... More
4.5 - 7.5 A THERMAL OVERLOAD RELAY 3 No
-
-
-
... More
For 4th Year
1
81141
81141.41
... More
6 A SP control MCB 3 No.
-
-
-
... More
300 mm width x 50mm depth x 1.6 mm thickness
25
777
19425
... More
Neutral link 2 No.
-
-
-
... More
BUS BAR & HARDWARE
-
-
-
... More
CMC of 2600 CFM DX coil air handling unit along with 2-Nos of Condensing units(11 TR each) ,All associated control consoles, Exhaust fans, Electrical panels, and all other associated parts & controls of BSL lab at terrace Advance Eye Care Center, PGIMER, Chd (Only outside equipment of Lab). For 5-years after the of completion of above work(i.e. for 5-years, after one-year of DLP).(@5% of project value (Except Ducting, insulation, cable tray, dismantling of equipment and civil work) + 10000 for replacement of HEPA filters annually)
-
-
-
... More
32 A TPN 10 KA MCB curve type 1 No
-
-
-
... More
Fabrication in 2.0 / 1.6 mm CRCA sheet powder coating in siemens gray shade cable entry will be top & bottom suitable for cable lock rubber gasket hardware etc.
-
-
-
... More
Start delta timer 2 No.
-
-
-
... More
NOTE: This is a percentage rate tender, therefore, percentage is only to be quoted by the agency in figures on the amount mentioned in Schedule of quantity. The percentage quoted should be inclusive of all taxes including GST etc. and nothing extra shall be payable on this account.
-
-
-
... More
RY phase indicating lamp 240 V AC 2 No.
-
-
-
... More
SITC of machine with factory pre-charged refrigerant gas R410 Eco Friendly Refrigerant in circuit complete in all respect (including corded remote controls, dryer, expansion valve, lifting, shifting, loading, unloading of m/cs).
-
-
-
... More
MS work welded in build up sections/framed work, included cutting, hoisting, fixing position and applying a priming coast of approved steel primer including painting with Synthetic enamel paint etc. in drating, frames, guard bar, ladder and similar works etc as per site requirement. (40 x 40 x 5 mm)
2
3444
6888
... More
The AHU shall be insulated with 48+2 mm thick injected fire retardant PUF of density 40+2 Kg /m³ . The motor & fan assembly shall be mounted on aluminum extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should not exceed 500 FPM. The capacities of air handling shall be as follows
-
-
-
... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
-
-
-
... More
1.00 mm
10
1629
16290
... More
Supply installation testing and commissioning of PVC insulated armored Aluminum cabling 3.5 core 50 sq mm from electrical panel to AHU alongwith 6 SWG GI double earthing clamped on surface etc. complete in all respect as per specification and direction of engineer incharge.
15
674
10117.2
... More
12 A TP power contactor 3 No.
-
-
-
... More
A/M selector switch 3 No.
-
-
-
... More
Supply installation testing and commissioning of GI volume control damper complete with neoprene rubber gaskets, nuts, bolts ,screw linkages ,flanges etc as per specifications
1
7046
7046
... More
Spreader set 1 No.
-
-
-
... More
6 A SP control MCB 2 No
-
-
-