Chandigarh Administration Tender

... More
The Chandigarh Administration has issued a formal invitation for competitive bids for Renovation Of House No.2164 (type-viii) Sector-42, Chandigarh. (e.i. Work) in Chandigarh, with an estimated contract value of Rs. 63,931. The bid opening date for this tender is 12-03-2025 and the last date for bid submission is 18-03-2025. Interested bidders for Chandigarh Administration tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Chandigarh Administration Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Mar 2025
Closing Date18 Mar 2025
Tender Amount₹ 63,931 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DSR Item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

10

152

1520

... More
S/E of AC ceiling fans with copper winding but without regulator complete with Aluminium blades, plastic canopies 2 Nos. double ball bearing, MS hanging rods (As per site requirement), condenser, reels, clamps etc. The body of fan and blades should be white in color. The job includes the cost of making necessary connections from the adjacent light point with 1.5sq.mm single core copper conductor cable and 3mm thick white B.L. sheet cover for fan box of suitable size. The sample of fans shall be got approved from the Engineer in-charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer-In-Charge.

-

-

-

... More
4 Module (125 mm x 75 mm)

5

358

1790

... More
DSR 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

20

42

840

... More
2 way 5/6 amp. switch

4

155

620

... More
DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
Size 12 inch (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only.

1

4245

4245

... More
3 x 2.5 sq. mm

20

143

2860

... More
12 Module (200 mm x 150 mm)

5

572

2860

... More
DSR 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
6 Module (200 mm x 75 mm)

4

420

1680

... More
Group-B

2

666

1332

... More
3 x 1.5 sq. mm

30

99

2970

... More
DSR 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

12

498

5976

... More
3 pin 5/6 Amp. Socket outlet

10

127

1270

... More
Triple pole and neutral

1

1283

1283

... More
DSR 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

10

91

910

... More
Size 56” (1400mm) sweep ceiling fan of Crompton (High Speed)/ Havells (Velocity HS) / Orient (Summerbreeze)/ Usha (Striker)/ Bajaj (SABSE TEZZ EE) make only.

4

2570

10280

... More
8 Module (125 mm x 125 mm)

6

474

2844

... More
DSR 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

7

386

2702

... More
DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.

-

-

-

... More
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC.

-

-

-

... More
5/6 Amp. Switch

50

108

5400

... More
S/E of Bakelite holder ISI marked installed on exiting Jn. Box/ wooden block including connection etc as required. The holder should be of Anchor (Penta)/ Havells (Reo)/ Goldmedal (Essenza)/ SSK make only.

20

60

1200

... More
1 or 2 Module (75 mm x75 mm)

7

311

2177

... More
Single Pole

24

268

6432



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.