Border Security Force Tender

... More
The BSF has issued a formal invitation for competitive bids for the Border Security Force project, for Improvement/up-gradation Of Street Light Installed At Khagra Campus Bsf Under Shq Bsf Kishanganj in Kishanganj, Bihar, with an estimated contract value of Rs. 19,95,734. The bid opening date for this tender is 11-02-2025 and the last date for bid submission is 17-02-2025. Interested bidders for Border Security Force tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Border Security Force - BSF Tender - Bihar Tender

Opening Date11 Feb 2025
Closing Date17 Feb 2025
Tender Amount₹ 19,95,734.95 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Improvement/up-gradation Of Street Light Installed At Khagra Campus Bsf Under Shq Bsf Kishanganj

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

18.6

9045

168250.95

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required.

4

6855

27420

... More
Providing and fixing of Double arm brackt of 1000 mm length on two side with minimum 48.3 outer dia GI Pipe suitable for 70mm pole Top dia including fixing on existing octagonal pole etc as required.

4

2878

11512

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in same tranch in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. A) Upto 35 sq. mm

50

126

6300

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. i) 40 mm dia (OD-40 mm & ID-32 mm nominal)

125

125

15625

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), ncluding dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil

54

260

14056.2

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

850

70

59500

... More
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns

141

392

55293.15

... More
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.

18

196

3528

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

4.2

6812

28610.4

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. I) 63 mm dia (OD-63 mm & ID-51 mm nominal)

50

247

12350

... More
Supplying and fixing 0.5 amps to 6 amps rating, 240 volts, "C" curve, Single pole with DIN rail suitable for inductive load of following poles in the internal junction box of the GI pole complete with connections, testing and commissioning etc. as required. Make:- L&T/ Havells/ Schneider

46

502

23092

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.

8

287

2296

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. A) Upto 35 sq. mm

920

200

184000

... More
Providing and fixing of 7 Mtrs long hot dip galvanized octagonal pole with base plate made in single section fitted with erection of the pole on provided RCC Foundation with galvanized nuts etc as required. The following specifications should be adhered for pole & accessories :- a) Pole Top dia - 70mm b) Pole Bottom dia - 130 mm c) Thickness of sheet - 3mm d) Galvanized Base plate of size - 220mm X 220 mm X 12 mm e) Set of foundation nut & bolts - 04 nos EN 8 grade galavanized 700 mm length be supplied with galvaized nuts, washers, spacer plate & fixing template. The pole shall be fixed using double nuts. f) The set of GS anchor plates having thickness 4mm should be provided at all the connecting joints for providing support. g) The galvanization should be more than 65 micron DFT both inernally and externally and pole should be designed for at least 169 km/hour max wind speed i)The steel used for manufacturing pole should conform to BSEN 10025 GRADE S 355JO and for base plate steel should be Fe 410 conforming to IS 226 / IS 2062.

42

18786

789012

... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)

23

347

7982.15

... More
Providing, installation, testing & commissioning of 70 watt LED street light suitable for operating voltage 220 V, 50 Hz designed for all weather condtions with exellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection having Efficacy 110 LPW including 10 KV SPD, connection with 3 core 1.5 sqmm PVC copper cable from LED light to pole junction box etc as required. make Crompton / Havells/ Philips/ Bajaj.

46

7855

361330

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (i) Upto 35 sq. mm

170

37

6290

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more

908

107

97927.8

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (i) Above35 sq. mm Upto 95 sq. mm

50

57

2850

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required ( 50 mm dia )

6

762

4572.9

... More
SITC of outdoor/indoor type feeder panel made of 2mm thick CRCA sheet of desired size with 350mm depth suitable for 415 Volt, 3 phase 50 hz power supply complete with hinged doors, having locking arrangement and providing detachable gland plate of thickness 3mm at the bottom, earth bar/ stud, cable alley, Aluminium busbar of suitable size as per CPWD norms as required.. All sheet matel parts separately chemically treated with 7 tank treatment process and the panel shall be finished with powder coating in Siemens Grey shade RAL 7032 and supplied with suitable pedastal frame with 4 Nos 600mm long legs with suitable apron all around. The Panel Shall be embeded in 1:1.5:3 cement concrete foundation of required shape and size 30 cms below ground level including finishing etc as required as per direction of engg-in-charge. (Make of panel - CPRI approved only) (Drawing will be approved from department before fabrication)

0.72

46195

33260.4



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.