Northeast Frontier Railway Tender

... More
The NFR has issued a formal invitation for competitive bids for the Northeast Frontier Railway project, for At Rny - Electrical Works In Connection With Up Gradation & Augmentation Of Divisional Hospital At Rangiya. in Kamrup, Assam, with an estimated contract value of Rs. 83,23,999. The bid opening date for this tender is 10-06-2025 and the last date for bid submission is 07-07-2025. Interested bidders for Northeast Frontier Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Northeast Frontier Railway - NFR Tender

Works
Electronics Equipment
Electrical and Electronics
Ireps
Opening Date10 Jun 2025
Closing Date7 Jul 2025
Tender Amount₹ 83,23,999.76 
Notes
Download

Costs

Summary

At Rny - Electrical Works In Connection With Up Gradation & Augmentation Of Divisional Hospital At Rangiya.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Fixing and commissioning of ceiling fan 1200 mm sweep with suitable size GI pipe, MS hook, clamp, nut & bolts arrangements as required as per direction of EIC at site (Ceiling fan will be supplied by Railway )

60

35

2141.4

... More
Supply and concealed wiring of 6A 5 pin plug point concealed by PVC insulated and 08 un-sheathed FRLS multi stranded copper cable, single core 2.5 sq.mm with earth continuity by single core 1.0 sq mm copper cable through PVC heavy guage pipe including unbreakable concealed box. Cable connection to be done through modular controlling switch, socket installed in board, cover plate etc. with all accessories and as per direction of EIC at site.

150

393

58956

... More
Supply, carrying, loading &unloading of 5 mtr long withsuitable size designer singlebracket G I octagonal poleincluding base plate, junctionbox and foundation bolt 4x16Nos 40 (Length 450mm) etc. anderection with execution of CCfoundation work of size45cmx45cm in ratio 1:2:4 bycement,sand and chips of size19 mm and down upto full depth& 1ft above the GL as perdirection of EIC at site including 6A SP MCB. Make should be of Nezone/Utkarsh/Subham Poles Pvt Ltd.

10

13688

136886.8

... More
Supply & concealed wiring of Main line by 25.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site.

2200

371

817586

... More
Supply & concealed wiring of Submain/Main line by 6.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site.

900

56

51102

... More
Supply, installation, testing & commissioning of TPN distribution board 16 way double door metal TPN DB consisting 100A, MCB TPN - 1 no, 40A, MCB TPN - 3 nos, 16A, MCB DP - 2 nos with enclosure and necessary fixing arrangements as per direction of EIC at site.

-

-

20

... More
Supply & concealed wiring of Submain line by 2.5 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site.

1000

25

25090

... More
Supply & concealed wiring of earth continuity for Main line/ Submain line by 1.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable PVC heavy gauge pipe as required through the circuit as per direction of EIC at site.

1000

10

10310

... More
Supply, installation, testing & commissioning of 5.5 ton ductable AC including outdoor & indoor unit as per direction of EIC at site.

2

208700

417400.22

... More
Supply and Wiring of concealed exhaust fan/wall fan point by PVC insulated unsheathed and stranded Copper Cable 1.5 sq.mm S/C confirming to IS - 694 through PVC Concealed 03 rigid Conduit pipe of wall thickness 2mm of suitable size including flash type 6 A controlling modular switch and modular fan regulator on concealed unbreakable modular box, cover plate etc. with all accessories and ceiling rose /holder.etc. as required. from ceiling rose to fan as per direction of EIC at site.

50

236

11800.5

... More
Supply, fitting & fixing of garden bollard light as per direction of EIC at site.

-

-

45

... More
Supply, fixing, testing and commissioning of 400 mm sweep, heavy duty wall fan complete as required and fixing by suitable nuts and bolts arrangement through switch as per direction of EIC at site.

30

1432

42968.4

... More
Supply, testing & commissioning of 25A, 2 pole, 30mA, 10kA RCCB as per direction of EIC at site.

20

1952

39057.4

... More
Supply and concealed Wiring of AC point concealed by PVC insulated and un-sheathed FRLS multi stranded copper cable, single core 4.0 sq.mm through PVC heavy guage pipe with earth 10 continuity by 1.0 sq.mm multistand copper cable including MS concealed box. Cable connection to be done through modular controlling switch, socket installed in board and as per direction of EIC at site - 20A power unit (Model - AHLO202504 of Make - Havell's or Similar model of Kolors/Legrand/Anchor), concealed unbreakable modular box, cover plate etc. with all accessories should be commissioned as per direction of EIC at site.

30

674

20239.8

... More
Supply & concealed wiring of Submain/Main line by 4.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site.

800

38

30440

... More
Supply, installation, testing & commissioning of TPN distribution board 8 way double door metal TPN DB consisting 63A, MCB TPN - 1 no, 40A, MCB DP - 2 nos, 25A, MCB DP - 1 nos & 10A MCB SP - 2 nosand with enclosure and necessary fixing arrangements as per direction of EIC at site.

8

10713

85710.16

... More
Supply & concealed wiring of Main line by 10.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site.

500

140

70000

... More
Supply and wiring of concealed fan point by PVC insulated unsheathed and stranded 02 Copper Cable 1.5 sq.mm S/C confirming to IS - 694 through PVC Concealed rigid Conduit pipe of wall thickness 2mm of suitable size including flash type 6 A controlling modular switch on concealed unbreakable modular box, cover plate etc. with all accessories and ceiling rose /holder.etc. as required as per direction of EIC at site.

60

362

21739.2

... More
Supply and fixing of MS stand with painting for fixing of outdoor unit of RAC with all accessories as per direction of EIC at site.

20

750

15000

... More
Supply, fixing and commissioningof 800 mm sweep exhaust fan complete by cutting wall, masonary work as required and fixing by suitable nuts and bolts arrangement as per direction of EIC at site.

-

-

6

... More
Supply, installation, testing &commissioning of IP 65 45 watt street light fittings complete including all accessories as perdirection of EIC at site Lumensout put should be of 42 100Lumens/watt, LED should be asper LM-80/IS: 16105. LEDdriver's efficiency should beminimum 90%, Power factor ofcomplete fitting should begreater than 0.90, Inputoperating voltage: 140V to 277VAC and driver should be as perIEC: 62384/IS:16104. The LEDfittings should be warranted for5 years.

30

4452

133565.7

... More
Excavation of cable trench 0.75 mtrs. below the GL with laying of armored cable and refilling the same by supply of 70mm sand and soil after digging the earth. The laying of armoured cable should be done as per direction of Engineer at site. (Cable will be supplied by Railway).

-

-

36

... More
Fixing of water cooler with gril protection, making of floor, water connection and electrical connection as per direction of EIC at site. (Water cooler will be supplied by Railway)

2

3019

6039.46

... More
Supply, fixing and commissioning of 300 mm sweep exhaust fan complete by cutting wall, masonary work as required and fixing by suitable nuts and bolts arrangement as per direction of EIC at site.

10

1839

18398

... More
Supply & fixing of PVC heavy gauge pipe 32mm by concealing of wall for drawing of Main/Submain line as required as per direction of EIC at site.

500

105

52500

... More
Supply & concealed wiring of Main line by 16.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site.

500

224

112000

... More
Supply and concealed Wiring of 16A Plug point/geyser point concealed by PVC insulated and un-sheathed FRLS multi stranded copper cable, single core 4.0 sq.mm through PVC 09 heavy guage pipe with earth continuity by 1.0 sq.mm multistand copper cable including MS concealed box. Cable connection to be done through modular controlling switch, socket installed in board, concealed unbreakable modular box, cover plate etc. with all accessories and as per direction of EIC at site.

80

409

32731.2

... More
Supply and fixing of drinking water purifier as per direction of EIC at site.

-

-

33

... More
Supply, installation, testing & commissioning of SPN distribution board 8 way double door metal SPN DB consisting 40A, MCB DP - 1 no, 20A, MCB DP - 2 nos, 6A, MCB SP - 2 nos with enclosure and necessary fixing arrangements as per direction of EIC at site.

20

5118

102377.2

... More
Supply, installation, testing & commissioning of (2x2) feet LED recess square panel light fittings of 40 watt colour white including all accessories as per direction of EIC at site.

30

9037

271115.4

... More
Supply, testing, installation, commissioning & handing over of liquid filled 2900 watt Room heater as per EIC at site.

10

13829

138290

... More
Supply, installation, testing & commissioning of 2.0 ton 5 star rated split AC including 28 indoor, outdoor unit compressor rotary type suitable for operation on 230volt/1-ph/50 Hz and necessary copper pipe line along with insulation, wal fixing arrangements and other accessories for connecting indoor unit to outdoor unit with copper piping as per direction of EIC at site.

20

63446

1268926.6

... More
Laying of above LT XLPE insulated armoured aluminium cables as per instruction of site engineer (Cable will be supplied by Railway).

1300

12

16783

... More
Supply. Installation, testing and commissioning of outdoor MS cubical type LT feeder pillar box of suitable size and suitable for 415 V, 50 Hz AC supply made out of CRCA sheet not less than 14 SWG. The panel shall be totally enclosed, dust and vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units and beneath all covers so that the joints are effectively dust vermin proof. The busbar chamber shall have three phase & neutral 39 copper busbar of same ratings. The drawing of panel board should be approved by the competent authority before fabrication and commissioning. The panel shall be painted with two coats of primer & two coats of exterior coating by spray painting and shall consists of the following: (i) 163A, 4P, 36kA, Ics=100%Icu, Adjustable over load Setting & Short circuit setting, MCCB - 1 Nos. (ii) 63A, 4P, 36kA, Ics=100%Icu, Adjustable over load Setting & Short circuit setting, MCCB - 2 Nos. (iii) 40A, TPN, 'C' Series, MCB - 2 Nos. (iv) Fabrication of Panel board with 14SWG CRCA sheet including CC foundation and 200A TPN Copper busbar), cable alley, C C Foundation etc and all accessories - 1 job

2

69847

139695.02

... More
Supply, installation & commissioning of 10.0 KVA UPS with back up time 180 minutes as per direction of EIC at site.

2

1120000

2240000

... More
Supply, installation, testing & commissioning of 18/20W LED tube light fitting with polycarbonate housing with THD less than 20% and surge protection 1.5KV 6000K (4 ft) complete 26 with driver circuit etc and all accessories as per direction of EIC at site. Lumens out put should be not less than 100 Lumens/watt, LED should be as per LM-80/IS: 16105. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC and driver should be as per IEC: 62384/IS:16104. The LED fittings should be warranted for 5 years.

100

329

32911

... More
Supply, installation, testing & commissioning of 15 watt LED round recess mounting down light including all accessories as per direction of EIC at site.

50

1685

84280.5

... More
Supply and laying of HDPE pipe110 mm dia towithstand 8.0 Kg/sq mm pressure confirmingto IS:4984/2016 (complete with necessaryjointing of pipes as per standard procedure) asper direction of EIC at site.

1000

257

257910

... More
Supply, carrying, loading &unloading of 5 mtr long withsuitable size designer double 41 arm bracket G I octagonal poleincluding base plate, junctionbox and foundation bolt 4x16Nos (Length 450mm) etc. anderection with execution of CCfoundation work of size45cmx45cm in ratio 1:2:4 bycement,sand and chips of size19 mm and down upto full depth& 1ft above the GL as perdirection of EIC at site including6A SP MCB.

10

15689

156890

... More
Renovation of existing AC duct by replacement of exixting defective materials and re- installation as per direction of EIC at site.

100

1500

150000

... More
Supply. Installation, testing and commissioning of outdoor MS cubical type floor mounted indoor double door LT panel board of suitable size and suitable for 415 V, 50 Hz AC supply made out of CRCA sheet not less than 14 SWG. The panel shall be totally enclosed, dust and vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units and beneath all covers so that the joints are effectively dust vermin proof. The busbar chamber shall have three phase & neutral copper busbar of same ratings. The drawing of panel board should be 38 approved by the competent authority before fabrication and commissioning. The panel shall be painted with two coats of primer & two coats of exterior coating by spray painting and shall consists of the following: - (i) 250A, 4P, 50kA, Ics=100%Icu, Adjustable over load Setting & Short circuit setting, MCCB - 1 No. (ii) 150A, 4P, 36kA, Ics=100%Icu, Adjustable over load Setting & Short circuit setting, MCCB - 4 Nos. (iii) 63A, 4P, 36kA, Ics=100%Icu, Adjustable over load Setting & Short circuit setting, MCCB - 1 Nos. (iv) 3 Phase Digital Ammeter - 1 No.(v) 3 Phase Digital Voltmeter - 1 No. (vi) LED Indicator R/Y/B - 3 Nos.(vii) Fabrication of Panel board with 14SWG CRCA sheet including CC foundation and 300A TPN Copper busbar), cable alley, C C Foundation etc and all accessories - 1 job

2

185133

370266.94



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.