Indian Institute Of Technology Tender

... More
The IIT has issued a formal invitation for competitive bids for the Indian Institute Of Technology project, for Repairing Of Roof Slab At Corridor Area Of Brahmaputra Hostel (near Tv Or Library Room) In Iitg Campus in Kamrup, Assam, with an estimated contract value of Rs. 2,25,469. The bid opening date for this tender is 22-02-2025 and the last date for bid submission is 06-03-2025. Interested bidders for Indian Institute Of Technology tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Indian Institute Of Technology - IIT Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date22 Feb 2025
Closing Date6 Mar 2025
Tender Amount₹ 2,25,469 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Waterproofing Treatment: Surface Preparation: All loose traces of concrete or mortar, dust, grease oil, etc. must be removed to obtain a keyed aggregate exposed surface. Surfaces should be cleaned using some mechanical grinder. Crack Repairing: Make groove cutting at cracks. Supply and apply of High Grade Dual Shrinkage Compensated Pre Packed Cement Based Repair Mortar such as MasterEmaco S348 of MBS or equivalent using MasterEmaco SBR 3 of MBS make as bonding agent Coving: Prepare coving with fillet of size 50mm x 50mm with CM 1: 3 admixed with MasterEmaco SBR 3 of MBS (Mortar – 1:3/ 1:4) wherever required as per site requirement Coating: Supply and application of MASTERSEAL 551, an elastomeric flexible, two component acrylic modified cementitious coating applied by brush, roller or trowel. The product shall be applied in minimum two coats. Typical properties of the product shall be as follows: Density : 1.75 + 5% (kg/m³) Mixing Ratio (powder: Liquid): 2.6:1 by weight Water penetration: 5 bar, no leakage PotLife : 120 Minutes at 25o C 30 Minutes at 40o C Recoatable time : 8 – 12 Hours Elongation at break (ASTMD 412-2016): 40% Protection Screed / Plaster: Providing and laying 25mm – 50mm thick screed concrete / plaster mixed with approved water proofing compound like MasterPel 777 or equivalent (Integral waterproofing compound confirming to IS 2645) over the coated surface all complete as per manufacture's specifications and instruction and as directed.

20

-

-

... More
Epoxy Grouting: Nozzle Plugging: Fixing GI NRV nozzles in honey comb / damaged area and along crack lines at required spacing after drilling using mechanical tools and plugging it using high strength, non-sag, epoxy compound complying with ASTM C881 Type I, Grade 3, Class B & C and formulated to achieve adhesive bond strength with concrete substrate an average of 1 MPa at 7 days or concrete failure when tested to ASTM D4541; Compressive strength in excess of 40MPa at 1day & 60MPa at 7 days when tested as per BS:6310Pt2 Injection of Low Viscous Epoxy Resin: After fixing the injection ports at predetermine locations, grouting with the help of suitable injection grouting pumps at suitable pressures using two-component, high strength, low viscous (350 cps @ ambient temperatures) epoxy injection resin system having minimum pot life of 30 minutes at ambient temperatures, achieves compressive strength higher than 55 MPa at 1 day & 65 MPa at 7 days; Flexural strength higher than 55 MPa at 7 days; slant shear bond strength higher than 15 MPa in 7 days

15

-

-

... More
Repair of spalled concrete: Patch Repair with High Grade, Single Component, Dual Shrinkage compensated, fibre reinforced, pre packed Cement Based Repair Mortar that achieves compressive strength minimum of 45MPa at 28days as per as tested and capable of applying 50mm thick in single layer initially by hand and final finishing using trowel for thickness required as per site condition over a epoxy rasin bonding agent to ensure proper bonding of old and new concrete

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.