Department Of Agriculture Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Department Of Agriculture Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date17 Feb 2023
Closing Date18 Mar 2023
Tender Amount₹ 72,19,558
Costs
EMD
₹ 1,44,391Document Cost
₹ 1,440Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_DAASC_29379_2Bid Award Id
ViewTender No
ASC/ENGG/745/2023/5 Dtd. 15th Feb, 2023Tender Authority
Department Of Agriculture ViewPurchaser Address
-Website
http://assamtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Clearing jungle including uprooting of rank vegetation , grass, brush wood, trees and saplings of girth upto 30 cm measured at a higt of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
1258
-
-
... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
15
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
14.82
-
-
... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
23.83
-
-
... More
4.00 mm thick glass panes
12
-
-
... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
... More
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
19.9
-
-
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
... More
Cement mortar 1:4 (1 cement : 4 coarse sand)
26.98
-
-
... More
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
1.05
-
-
... More
Thermo-Mechanically Treated bars of grade Fe-500D or more
7977.77
-
-
... More
Supplying chemical emulsion in sealed containers including delivery as specified.
-
-
-
... More
Providing and fixing glass strips in joints of tarrazo/ cement conceret floors
-
-
-
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
-
-
-
... More
80x1.25 mm M.S. laths with 1.25 mm thick top cover
14.3
-
-
... More
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
35.07
-
-
... More
Finishing walls with water proofing cement paint of required shade :
-
-
-
... More
Group A
5
-
-
... More
Single pole.
12
-
-
... More
Cement mortar 1:4 (1 cement :4 coarse sand)
248.32
-
-
... More
15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix
-
-
-
... More
63A
6
-
-
... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
75
-
-
... More
Group C.
19
-
-
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
-
-
-
... More
1:4 (1 cement: 4 fine sand)
509.52
-
-
... More
Foundations, footings, bases of columns, etc. for mass concrete
86.71
-
-
... More
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
130
-
-
... More
All kinds of soil
441.65
-
-
... More
Proving & fixing UV stabilised fiber glass reinforced plastic sheet roofing upto any pitch, including fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3 % ultera - violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness with out air pockets and shall confirm to IS : 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmrnted, texture or smooth as specified.
-
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual meansover areas ( exceeding 30cm in depth,1.5m in width as well as 10 sqm on plan), including getting out and disposal of excavated earth lead up to 50m and lift up to 1.5 m, as directed by Engineer-in-charge.
-
-
-
... More
All kinds of soil
215.7
-
-
... More
Vertical and horizontal fins individually or forming box louvers
band, facias and eaves boards
11.66
-
-
... More
Finishing with Deluxe Multi surface paint system for interriors and exteriors using primers as per manufactures specifications:
-
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
120
-
-
... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
10
-
-
... More
Hot finished welded type tubes
7666.56
-
-
... More
Proving & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with:
-
-
-
... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
-
-
-
... More
Banking exacavated earth in layers not exceeding 20 cm in depth, breaking clods , waterring, rolling each layer with 1/2 tonne roller, or wooden or stell rammers and rolling every 3rd and top most layer with power roller of minimum 8 tones and dressing up , in embankments for roads, floood bank, marginal banks, guide banks etc, lead upto 50 meter and lift upto 1.5 meter.
-
-
-
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.).
-
-
-
... More
Providing ridges or hips of width 60 cm overall width plain G.S sheet fixed with polymer coated J or L hooks, bolts and nuts 8 m dia G.I. limpet and bitumen washers complete.
-
-
-
... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
-
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
... More
Lintels, beams, plinth beams, girders, bressumers and
cantilevers
263.73
-
-
... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
581.63
-
-
... More
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
9.93
-
-
... More
Proving and fixing angle iron frames for doors, windows and ventilators of mild steel Angled sections of size 35 X 35 x 5 mm, joints mitred and welded by angle iron 35 X 35 X 5 mm or 35 X 5 mm flat pieces to the existing T- iron frame or to the wall with dash fastener , including fixing of necessary butt hings and screws and applying a priming coat of approved steel primer , all complete as per the direction of Engineer- In-charge
144
-
-
... More
Group B
6
-
-
... More
Random rubble masonary with hard stone in foundation and plinth including levelling up with cement concrete 1;6:12(1 cement:6 Coarse sand:12 Graded stone aggregate 20mm nominal size) up to plinth level with
-
-
-
... More
New work (Two or more coats applied @ 3.84 kg/10 sqm)
1057.85
-
-
... More
Proving corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins , rafters and trusses and including cutting to size and shape wherever required.
-
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
0.63 mm thick zinc coating not less than 275 gm/m2
27.25
-
-
... More
Cement morter 1:6(1 Cement:6 Coarse sand0
47.75
-
-
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
137
-
-
... More
4 way (4 + 12), Double door.
3
-
-
... More
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
-
-
-
... More
Painting Steel work with Deluxe Multi Surface Paint to give and even shade .Two or more coat applied @ 0.90 ltr/10 sqm over and under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
58
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
-
-
-
... More
Double pole.
6
-
-
... More
1:4 (1 cement: 4 fine sand)
548.3
-
-
... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement
-
-
-
... More
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
579.63
-
-
... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average with of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.
-
-
-
... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
100.7
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed required.
-
-
-
... More
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to I.S 2222 in superstructure above plinth level upto floor five level in cement mortal 1:6 (1 cement :6 coars sand)
-
-
-
... More
40 mm thick with 20 mm nominal size stone aggregate
581.63
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
90
-
-
... More
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
105
-
-
... More
Supplying, installation, testing and Commission of the following All in one (AIO) Solar street light (30 W) with high efficiency mono crystalline solar PV module, lithium ferro phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar charge controller and aluminium extruded body. PIR motion Sensor for automatic controlling of dimming and brightness of light, which increase the backup time ( including pole of length 7.00 metre)
2
-
-
... More
40 A
2
-
-
... More
12 mm cement plaster of mix :
-
-
-
... More
Columns, Pillars, Piers, Abutments, Posts and Struts
133.5
-
-
... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
30
-
-
... More
With Modular bricks
48.72
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
... More
a) 18 mm thick
20.8
-
-
... More
40 mm wide and 4 mm thick
350
-
-
... More
Excavating, supplying and filling of local earth (including royality) by mechanical transport up to a lead of 5Km also including ramming and watering of the earth in layers not exceeding 20cm in trences, plinth,sides of foundation etc.complete
404.56
-
-
... More
ELECTRICAL
-
-
-
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
-
-
-
... More
15 mm cement plaster on the rough side of single or half brick wall of mix :
-
-
-
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
-
-
-
... More
1:4 (1 cement: 4 fine sand)
81.5
-
-
... More
2 mm thick corrugated (2.5 " or 4.2" or 6") or step-down(2" or 3" or 6") as specified
43.2
-
-
... More
With 2nd class teak wood beading 52 X19 mm
15.84
-
-
... More
0.63 mm thick zinc coating not less than 275 gm/m2
631.14
-
-
... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
-
-
-
... More
(A) Civil works:
-
-
-
... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
-
-
-