Bodoland Territorial Council Tender

... More
The BTC has issued a formal invitation for competitive bids for the Bodoland Territorial Council project, for Construction Of Jaleswar Basumatary Guest House At Parkijuli (g Plus 1, 15 Rooms With Meeting Hall). Package No. Tn_54_05 in Baksa, Assam, with an estimated contract value of Rs. 4,83,17,123. The bid opening date for this tender is 07-11-2026 and the last date for bid submission is 27-11-2026. Interested bidders for Bodoland Territorial Council tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Bodoland Territorial Council - BTC Tender - Assam Tender

Opening Date7 Nov 2026
Closing Date27 Nov 2026
Tender Amount₹ 4,83,17,123 
Notes
Download

Costs

Summary

Construction Of Jaleswar Basumatary Guest House At Parkijuli (g Plus 1, 15 Rooms With Meeting Hall). Package No. Tn_54_05

Description

Construction Of Jaleswar Basumatary Guest House At Parkijuli (g Plus 1, 15 Rooms With Meeting Hall)

AI Insights

Unlock AI Insights for this Tender

Sign in to request AI-powered insights, eligibility criteria and automated analysis for this tender.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
5.22: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

15132.81

-

-

... More
5.22A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

41927.24

-

-

... More
5.9: Centering and shuttering including strutting, propping etc. and removal of form for - 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete

315.9

-

-

... More
5.9.6: Columns, Pillars, Piers, Abutments, Posts and Struts

503.16

-

-

... More
5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers

1556.79

-

-

... More
5.9.3: Suspended floors, roofs, landings, balconies and access platform

1133.64

-

-

... More
5.9.7: Stairs, (excluding landings) except spiral-staircases

26.25

-

-

... More
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

141.37

-

-

... More
5.2: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

43.13

-

-

... More
5.3: Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

243.45

-

-

... More
6.1: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

106.29

-

-

... More
6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in uperstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)

1244.47

-

-

... More
13.5: 15 mm cement plaster on rough side of single or half brick wall of mix : 13.5.1 1:4 (1 cement: 4 coarse sand)

3215.34

-

-

... More
13.1: 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)

1159.89

-

-

... More
13.26: Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

4375.23

-

-

... More
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm

4375.23

-

-

... More
9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood

3.14

-

-

... More
9.6: Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately) 9.6.3 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade -1, Type II marked :

86.1

-

-

... More
9.55: Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 9.55.1 125x65x2.12 mm

252

-

-

... More
9.66: Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.66.1 125 mm

80

-

-

... More
9.63: Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.63.2 200x10 mm

80

-

-

... More
9.65: Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 9.65.1 300x20x6 mm

40

-

-

... More
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture

172.2

-

-

... More
26.86: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 26.86.5 Frame size 65 x 100 mm

108.9

-

-

... More
26.87: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.2 35 mm thick

34.65

-

-

... More
9.147D: Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 9.147D.1 Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)

122.58

-

-

... More
9.48: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.

941.6

-

-

... More
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture

243.7

-

-

... More
11.41A: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.2 Glazed vitrified floor tiles polished finish of size 11.41A.2.4 Size of Tile 800 x 1200 mm

1201.94

-

-

... More
8.31: Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete.

468.76

-

-

... More
10.16: Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes

2697.6

-

-

... More
12.45: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board

1121.39

-

-

... More
Construction of Boundary Wall: 2.8: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. cum

144

-

-

... More
16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

96

-

-

... More
4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).

7.2

-

-

... More
5.22: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

3566.4

-

-

... More
5.22A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

2536.93

-

-

... More
5.9: Centering and shuttering including strutting, propping etc. and removal of form for - 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete

153.33

-

-

... More
5.9.6: Columns, Pillars, Piers, Abutments, Posts and Struts

120

-

-

... More
5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers

80

-

-

... More
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

38.53

-

-

... More
5.2: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

7.47

-

-

... More
5.3: Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

10

-

-

... More
6.3: Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : 6.3.1 With F.P.S.(non modular) bricks

44.13

-

-

... More
13.5: 15 mm cement plaster on rough side of single or half brick wall of mix : 13.5.1 1:4 (1 cement: 4 coarse sand)

424

-

-

... More
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm

424

-

-

... More
10.25: Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1440

-

-

... More
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

96

-

-

... More
Construction of Gate: 2.8: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. cum

23.32

-

-

... More
16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

12.96

-

-

... More
4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).

0.98

-

-

... More
5.22: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

472.76

-

-

... More
5.22A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

203.1

-

-

... More
5.9: Centering and shuttering including strutting, propping etc. and removal of form for - 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete

20.64

-

-

... More
5.9.6: Columns, Pillars, Piers, Abutments, Posts and Struts

15.36

-

-

... More
5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers

7.2

-

-

... More
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

7.68

-

-

... More
5.2: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

1.54

-

-

... More
13.4: 12 mm cement plaster of mix : 13.4.1 1:4 (1 cement: 4 coarse sand)

16

-

-

... More
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm

16

-

-

... More
10.25: Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

672

-

-

... More
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

16.8

-

-

... More
RCC Covered Drain: 2.8: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. cum

129.6

-

-

... More
16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

144

-

-

... More
4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).

10.8

-

-

... More
5.22: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

7566.87

-

-

... More
5.9: Centering and shuttering including strutting, propping etc. and removal of form for - 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete

492.8

-

-

... More
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

61.2

-

-

... More
13.9: Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 13.9.2 20 mm cement plaster

288

-

-

... More
Construction of Septic Tank: 2.8: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. cum

103.04

-

-

... More
16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

57.24

-

-

... More
4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).

4.28

-

-

... More
5.22: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

816.92

-

-

... More
5.22A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

598.32

-

-

... More
5.9: Centering and shuttering including strutting, propping etc. and removal of form for - 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete

8.6

-

-

... More
5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers

13.24

-

-

... More
5.9.3: Suspended floors, roofs, landings, balconies and access platform

48

-

-

... More
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

9.6

-

-

... More
5.3: Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

6

-

-

... More
6.1: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

26.88

-

-

... More
6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in uperstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)

17.4

-

-

... More
13.7: 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.7.1 1:3 (1 cement: 3 fine sand)

298.76

-

-

... More
Construction of Sanitary Works: 17.2: Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid

21

-

-

... More
17.4: Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern

21

-

-

... More
17.6: Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern

21

-

-

... More
17.7: Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

21

-

-

... More
18.8: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.2 20 mm nominal dia Pipes

900

-

-

... More
18.9: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.5 40 mm nominal dia Pipes

400

-

-

... More
17.35: Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729

120

-

-

... More
18.15: Providing and fixing brass bib cock of approved quality : 18.52.2 20 mm nominal bore

70

-

-

... More
18.58: Providing and fixing PTMT grating of approved quality and colour. 18.58.1 Circular type 18.58.1.1 100 mm nominal dia

40

-

-

... More
18.55: Providing and fixing PTMT stop cock of approved quality and colour. 18.55.2 20 mm nominal bore, 89 mm long, weighing not less than 88 gms

78

-

-

... More
17.22B: Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia

21

-

-

... More
17.16A: Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

21

-

-

... More
17.31: Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

21

-

-

... More
Plumbing Works: 23.1: Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1All types of soil 23.1.1.1 300 mm dia

60

-

-

... More
23.10: Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 23.10.1 100 mm nominal size dia having minimum wall thickness 5.00 mm

60

-

-

... More
23.8: Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

2

-

-

... More
23.15: Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 23.15.1 100 mm dia

1

-

-

... More
18.12: Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 8.12.6 50 mm dia nominal bore

80

-

-

... More
18.9: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.6 50 mm nominal dia Pipes

80

-

-

... More
18.17: Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.4 50 mm nominal bore

3

-

-

... More
18.90: Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° 18.90.6 For 48.60 mm outer dia pipe

3

-

-

... More
18.90A: Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° 18.90A.6 For 54 mm outer dia pipe

2

-

-

... More
18.92A: Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Equal Tee 18.92A.6 For 54 mm outer dia pipe

2

-

-

... More
18.48: Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

6000

-

-

... More
MR-1: Submersible Pump (Electric, 5HP, 100 mm Bore)

1

-

-

... More
MR-2: Suppy & Isntallation Rapid Sand Filter

1

-

-

... More
Internal & External Electrification Works: 1.10: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 1.10.1 Group A

500

-

-

... More
1.14: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 1.14.1 a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

2000

-

-

... More
1.14.4 b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

1200

-

-

... More
1.14.11 c) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

400

-

-

... More
1.21: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20 mm

800

-

-

... More
1.21.3 32 mm

200

-

-

... More
1.27: Supplying and fixing following size/modules, GI Box along with modular base and cover plate for modular switches in recess etc as required. 1.27.3 4 Module (125mmX75mm)

40

-

-

... More
1.27.4 6 Module (200mmX75mm)

18

-

-

... More
1.27.6 12 Module (200mmX150mm)

10

-

-

... More
1.24: Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch

220

-

-

... More
1.24.3: 15/16 A switch

30

-

-

... More
1.24.4: 3 pin 5/6 A socket outlet

38

-

-

... More
1.24.5: 6 pin 15/16 A socket outlet

30

-

-

... More
1.26: Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

76

-

-

... More
MR-1: Crompton - 50W Gleam Led Flood Light - CDL

10

-

-

... More
MR-2: Crompton Rover Plus_150W

2

-

-

... More
MR-3: 36w Cool White Bajaj LED Panel Light Square, Base Type: 2 ft X 2 ft

12

-

-

... More
MR-4: Philips AP Plus UltraGlow 15W LED Downlight

150

-

-

... More
MR-5: Philips Saturn Ceiling light (IP44 rating)

15

-

-

... More
MR-6: Orient Electric - K Type 2 Way Deco LED Wall Light 6W Warm White

50

-

-

... More
MR-7: Philips Elevate 3 head Pendant light

6

-

-

... More
MR-8: Philips Celestial 12 head Chandelier (French Gold)

4

-

-

... More
MR-9: Bajaj Energon BLDC ceiling fan, 1200 mm, 350 RPM

36

-

-

... More
MR-10: LG 5 Star 5.0 kW (~1.5) Split AC, AI Convertible 6-in-1, Diet Mode+, Viraat Mode, 100% Copper Tubes, 2026 Model

28

-

-

... More
MR-11: Luminous Inverlast ILTT 28060 Tall Tubular Inverter Battery – 250 Ah Capacity

5

-

-

... More
MR-12: Luminous Eco Volt Neo 2300 Pure Sine Wave Inverter | 2000 VA Capacity

5

-

-

... More
2.3: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.3 12 way, Double door

5

-

-

... More
2.10: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 a) Single pole

68

-

-

... More
6.2: Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

1

-

-

... More
6.7: Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

10

-

-

... More
6.8: Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)

20

-

-

... More
6.12: Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required

1

-

-

... More
5.4: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

-

-

... More
5.16: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required

15

-

-

... More
5.18: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

15

-

-

... More
5.12: Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required

15

-

-

... More
6.14: Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required

15

-

-

... More
Earthfilling Works: 2.25(a): Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

3866

-

-

... More
Landscaping & Plantation Works: 2.2: Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).

80

-

-

... More
2.4: Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : 2.4.3 Screened through sieve of I.S. designation 4.75 mm

60

-

-

... More
2.8: Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

60

-

-

... More
5.12: Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge

110

-

-

... More
5.22: Providing and Displaying Ficus Nuda topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 180to 210cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.

80

-

-

... More
7.71: Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.

80

-

-

... More
6.7: Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multi branched in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

2000

-

-

... More
4.32: Providing and Displaying Geranium double variety having 30 cm ht., in different colour well developed with fresh & healthy foliage (3 in one) well bloomed in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

800

-

-

... More
5.36: Providing and Displaying Mascarena palm well developed with fresh & healthy foliage leaves 150 to 180 cm ht in 35 cm Cement Pot as per direction of the officer-in-charge.

50

-

-

... More
5.11: Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.

40

-

-

... More
5.13: Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge.

22

-

-

... More
2.33: Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.

480

-

-

... More
Concrete Block Pavement: 2.25(a): Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

36

-

-

... More
16.78: Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.2 With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25

60

-

-

... More
16.3: Supplying and stacking at site. 16.3.3 53 mm to 22.4 mm size stone aggregate

60

-

-

... More
16.4: Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.

60

-

-

... More
16.91: Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

240

-

-

... More
4.4: Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 4.4.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

8.1

-

-

... More
4.3: Centering and shuttering including strutting, propping etc. and removal of form work for: 4.3.2 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

108

-

-

... More
Supply of Furniture Items & Appliances: MR: Radiance Open Shelf Book Cabinet (Warm Grey)

1

-

-

... More
MR: KD Plain Metal Storage Cupboard - Full Height (Bond White)

12

-

-

... More
MR: Core 8 Door Low Height Metal Locker Unit with Cam Lock (Sugar White)

1

-

-

... More
MR: Hive 8 Compartments Open Storage Cabinet (Sugar White)

1

-

-

... More
MR: Unitized - T20 Office Desk

8

-

-

... More
MR: Trident Junior 1 Executive Desk 1200 W

6

-

-

... More
MR: Nilkamal Contract 02 with Arm Visitor Chair (Black)

30

-

-

... More
MR: Eden V2 Queen Size Wooden Bed with Pullout Storage

16

-

-

... More
MR: Adria Single Size Wooden Bed

4

-

-

... More
MR: Monarch 5-Seater Leatherette Sofa Set (3+1+1)

3

-

-

... More
MR: Jack 6-Seater MDF Engineered Wood Rectangular Dining Set

3

-

-

... More
MR: Ace Pro 4-Seater Solid Rubberwood Square Dining Set

2

-

-

... More
MR: HM Home Made Fort Essential - Curtain

86

-

-

... More
MR: Meraki Particle Board Coffee Table

20

-

-

... More
MR: 26 cm (50) LG NANO 4K UHD TV 50NU870BPLA with α7 Processor Gen9, HDR10 Pro 2026 Model

12

-

-

... More
MR: LG 343L Double Door Refrigerator, Convertible, Smart Diagnosis™, Dazzle Steel, 2 Star

1

-

-

... More
MR: LG 8L RO+UV+UF+Mineral Booster Water Purifier with Steel Tank, Black

2

-

-

... More
MR: Upmods Freya Synthetic Leather Dining Chair (Set of 2)

16

-

-

... More
MR: Nilkamal Bold Executive Office Chair

8

-

-

... More
Supplying & Installation of Diesel Generator: MR: Supplying, Transportation, Isntallation, Testing & Commissioning of Diesel Generator 30 Kva Escorts Silent Diesel Generator

1

-

-

... More
Supplying & Installation of Solar Power Plant: MR: Luminous - LUM 24545M-DCR (Bifacial), 1 N Solar Panel, 545W

46

-

-

... More
MR: Luminous - Solar Battery 200 Ah - LPTT12200H, 1N Battery

20

-

-

... More
MR: Luminous - Solar Hybrid Inverter - TX 5 KVA, 1N Inverter

3

-

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.