Assam University Tender
... More
The Assam University has issued a formal invitation for competitive bids for Electrical Repairing Works For Outdoor Feeder Pillar For The Power Intensive Science Complex 500 Kva Dtr Panel ,aus. in Cachar, Assam, with an estimated contract value of Rs. 4,61,586. The bid opening date for this tender is 07-12-2023 and the last date for bid submission is 14-12-2023. Interested bidders for Assam University tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 9,240Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_AUS_784301_1Bid Award Id
ViewTender No
AU/Engg/Maint/Elect/99/2023Tender Authority
Assam University ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
185 Sq. mm.3 & 1/2 Core armoured U.G. cable
30
-
-
... More
LED Indicator RGY
2
-
-
... More
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Havells/ RPG/CCI/ / Finolex make) .
-
-
-
... More
Painting and repairing of existing feeder pillars with required welding of door hinges ,scarping and sand papering of the panel surface and applying two coats of approved paint as directed by deptt.
2
-
-
... More
10.1) Supply of 16 SWG mild steel sheet with required cutting and welding at site as per existing panel size requirement complete as directed by department.
15
-
-
... More
Cleaning painting and repairing of existing feeder pillars with required wielding of door hinge and required size metal sheet (18swg) scraping and sand papering of the panel surface and applying two coats of approved paint as directed by deptt.
2
-
-
... More
250 A , DIN Type with fuses complete.(L&T/Havells/Legrand)
4
-
-
... More
DIN type Fuse Base 400A
6
-
-
... More
Ammeter and Voltmeter selector switch
2
-
-
... More
150 Sq. mm.3 & 1/2 Core armoured U.G. cable
30
-
-
... More
Spreader terminal with phase barrier (250A/400A)
4
-
-
... More
800A , Bolted Type with fuses complete. (L&T/Havells/Legrand)
1
-
-
... More
10.2) PCC (1:2) works for power panel base and DTR base repairing as per site condition complete as directed by the department.
2
-
-
... More
SITC of existing panel door mounted extended rotary handle for operation of the moulded case circuit breaker. The handle must be be compatible for existing feeder pillar and SDFU as per site condition and as complete with fixing accessories as directed
7
-
-
... More
Painting of DTR and DTR fencing with two coats of synthetic enamel painting with required scraping and cleaning complete as directed by department
1
-
-
... More
Supply installation of heat resistant self adhesive high tension insulation tape for insulating electric cable/wires complete as required(Make 3M) (size 19-25mmX9.15 mtrx0.70mm)
6
-
-
... More
400 A , DIN Type with fuses complete. (L&T/Havells/Legrand)
2
-
-
... More
SITC of step type 400 A TPN BBC (Cu) with 4 o/g ways as required the busbar shall be installed on outdo orsIP 42 suitable for outdoor mounting arrangement with legs and GI roof for panel installation complete with necessary PCC base and painting complete as directed by the department. (L&T/Havells/Legrand)
1
-
-
... More
Supplying with fitting and fixing Four Pole switched neutral 415V 50Hz AC23A duty double break open execution panel mounting cubical type Switch Disconnection as approved by the Deptt.tor Fuse Unit (IP-20 protection, AC -23A,50hz,415V) with HBC fuse of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
-
-
-
... More
400 Sq. mm.3 & 1/2 Core armoured U.G. cable
30
-
-
... More
Multifunction meter (A,V,Hz,Pf) with 200/5A CT connection complete.
2
-
-