Uttarakhand Renewable Energy Development Agency Tender

View complete overview of Uttarakhand UREDA Tender

Uttarakhand Renewable Energy Development Agency

Air Compressor
Views295 Views
Downloads122 Downloads

Opening Date

11 Oct 2021

Closing Date

02 Nov 2021

Tender Amount

₹ 1,00,00,000

Costs

Summary

Design Supply Erection Testing And Commissioning Of Eandm Work Of Gauri Chhina Shp Capacity 2 X125 Kw On Turn Key Basis Including 5 Years Operation And Maintenance District Pauri Garhwal Uttarakhand

Description

Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    Unregistered TenderId
  • BidAward Id

    Unregistered BidAwardId
  • Tender No

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Tender Authority

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Purchaser Address

    Authority for unregistered User
  • Email

    Data for unregistered User
  • Website

    wwww.unregistereduser.com
Documents

BOQ Items

ItemQuantityUnitsRateAmount
... more
SCHEDULE OF RATES FOR ERECTION TESTING AND COMMISSIONING
---
... more
Design, Supply, Erection, testing and commissioning of Francis/Turgo impulse or any other (cross flow turbine not accepted) turbine to deliver 125 kW out put at generator terminal with Oil Pressure unit, electronic governor, cooling water system and other required system and accessories.required for proper completion of work.
2Set--
... more
Design, Supply, Erection, testing and commissioning of Synchronous Generator – 160Kva ,0.8 PF, 415 volts 3- Phase 50 Hz,1500 rpm and other accessories . required for proper completion of work.
2Set--
... more
Design, Supply, Erection, testing and commissioning of 500 mm Main Inlet Valve PN- 24,SS/DS material with hydrolic servo cylinder,Ded weight and mounting assembly complete required for proper completion of work.
2Set--
... more
Design,Supply, Erection, testing and commissioning of PLC based Turbine control panels including generator protection relays, metering system, switches ,Excitation system with AVR and APFR for on Grid operation required for proper completion of work.
2Set--
... more
Design, Supply, Erection, testing and commissioning of Electronic Load Controller 125 Kw, Delta connected ballast load ,Suitable for GRID Synchronization in auto mode complete required for proper completion of work.
2Nos--
... more
Design, Supply, Erection, testing and commissioning of Generator control and Relay panels consisting of 415V,800A ACB, generator protection relays, metering system, CTs,PTs annunciation and synchronization. complete required for proper completion of work.
2Set--
... more
Design, Supply, Erection, testing and commissioning of Transformer/ outgoing protection panel consisting of 415V,800A ACB, generator protection relays, metering system,CTs,PTs for on Grid operation required for proper completion of work..
1Set--
... more
Design, Supply, Erection, testing and commissioning of Expansion joints 500mm between Turbine and BFB for maintenance. required for proper completion of work..
2Nos--
... more
Supply and Installation of 200 AH 24 V Batteries with charger & DB .
1Set--
... more
Design, Supply, Erection, testing and commissioning of L. T. Distribution Board with 25 kVA 415/415 V Isolating transformer, CTs, PTs, measuring Instruments, relays MCCB and MCB etc. required for proper completion of work..
1Set--
... more
Supply and Installation of Power and Control Cables with junction boxes, cable boxes, lugs, connectors as required for completion of work and laying of cables.
1LS--
... more
Design, Supply, Erection, testing and commissioning of 315 kVA 415/11000 V step up transformer
1Nos--
... more
Design, Supply, Erection, testing and commissioning of 5 Tons E.O. T. Crane with complete gantry.
1Nos--
... more
Design, Supply, Erection, testing and commissioning of 11 kV,630 A, 16 kA Indoor type Vacuum Circuit Breaker with CTs, PTs, Relays, Measuring Instruments etc. (One for power house and one for 33 kV S/S Syunsi)
1Nos--
... more
Supply and erection of H T, 12 Kv,185 Sqmm three core XLPE Al.Ar.cable as per site requirement.
50Mtr--
... more
Supply and installation of 11 Kv Three phase 4 wire ABT energy meter accuracy class 0.25 for active and reactive energies with RS232,RS 485 Ethernet and optical port asper latest technical specifications and including testing from UPCL.
2Nos--
... more
Supply and Installation of 11 KV Metering panel 11KV/110V,CT 20/1A class0.25 having provision of mounting the ST Meteres for import/Export of the energy complete in all respect as per UPCL norms.
1Nos--
... more
Fire Fight System
4Nos--
... more
Ventilation System
4Nos--
... more
Lighting system including fittings
1LS--
... more
Earthing system of P/H
1LS--
... more
Lightning System
1LS--
... more
Miscellaneous as required for completion of the E&M works
1LS--
... more
Training for operation and maintenance personals
---
Evaluation Notes How It Works ?

Result

No Result Available
Click here to view all tender results of this authority
Business Providers

Check Business Providers

Business Seekers

Check Business Seekers

https://bidassist.com/pricing/1?referer=Banners
7 DAY
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.
whatsapp chat