Tender Results of Banaras Hindu University
Tender Results of Banaras Hindu University
Select Contract Period
2023 onwards
2021 onwards
All Time
Banaras Hindu University - BHU Tender Result
Works
Building Construction...+1Civil And Construction
Eprocure
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
Construction Of Ladies Toilet Along With Electrical Installation Work Adjunct To The Committee Room No. 1 In The Central Registry, Bhu
Contract Date27 Jul 2024
Contract Amount₹ 3.5 Lac
This is an estimated amount, exact amount may vary.
Banaras Hindu University - BHU Tender Result
Goods
Healthcare and Medicine
GEM
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
Digital Medical X - Ray Films (v2)
Contract Date23 Jul 2024
This is an estimated contract date, exact date may vary.
Contract Amount₹ 92.2 Lac
Banaras Hindu University - BHU Tender Result
Civil And Construction...+2Civil Works Others, Road Construction
Eprocure
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
Construction Of Road And Boundary Wall For The Residential Quarter Behind Moona Devi Hostel, Bhu
Contract Date22 Jul 2024
Contract Amount₹ 14.5 Lac
Banaras Hindu University - BHU Tender Result
Works
Eprocure
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
Aomc Of Hvac System In Trauma Centre ,super Speciality Hospital, Psychiatry Building, Non Comprehensive Maintenance Contract Of Bmt Stem Cell Research Centre In Trauma Centre Premises, Ims, Bhu, Varanasi
Contract Date22 Jul 2024
Contract Amount₹ 2.3 Cr
This is an estimated amount, exact amount may vary.
Banaras Hindu University - BHU Tender Result
Goods
Healthcare and Medicine
GEM
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
Digital Medical X - Ray Films (v2)
Contract Date20 Jul 2024
This is an estimated contract date, exact date may vary.
Contract Amount₹ 85.1 Lac
Banaras Hindu University - BHU Tender Result
Goods
Software and IT Solutions
GEM
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
CATEGORY: Workstation (Q2)
Contract Date20 Jul 2024
This is an estimated contract date, exact date may vary.
Contract Amount₹ 9.6 Lac
This is an estimated amount, exact amount may vary.
Banaras Hindu University - BHU Tender Result
Goods
Healthcare and Medicine
GEM
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
BOQ ITEMS: Inj. 0.9% Nacl I.V. infusion PVC/DEHP free Closed System standable container fully collapsible with two clearly defined injection port covered with aluminum foil, free from latex, compatible with all drugs for admixtures and eco friendly should be available in 100ml, clearly mentioning product label conforming to international color coding., Inj. 0.9% Nacl I.V. infusion PVC/DEHP free Closed System standable container fully collapsible with two clearly defined injection port covered with aluminum foil, free from latex, compatible with all drugs for admixtures and eco friendly should be available in 500 ml, clearly mentioning product label conforming to international color coding., Inj. Glucose 5% I.V. infusion PVC/DEHP free Closed System standable container fully collapsible with two clearly defined injection port covered with aluminum foil, free from latex, compatible with all drugs for admixtures and eco friendly should be available in 500 ml, clearly mentioning product label conforming to international color coding., Inj. Ringer Lactate I.V. infusion PVC/DEHP free Closed System standable container fully collapsible with two clearly defined injection port covered with aluminum foil, free from latex, compatible with all drugs for admixtures and eco friendly should be available in 500 ml, clearly mentioning product label conforming to international color coding., Inj. 0.9% Nacl and 5% Glucose I.V. infusion PVC/DEHP free Closed System standable container fully collapsible with two clearly defined injection port covered with aluminum foil, free from latex, compatible with all drugs for admixtures and eco friendly should be available in 100ml, clearly mentioning product label conforming to international color coding., Inj. 3.0% Nacl I.V. infusion PVC/DEHP free Closed System standable container fully collapsible with two clearly defined injection port covered with aluminum foil, free from latex, compatible with all drugs for admixtures and eco friendly should be available in 100ml, clearly mentioning product label conforming to international color coding., inj. 25% Dextrose i.v. infusion, inj. 20% Mannitol i.v. infusion, inj. Metronidazole 100 ml i.v. infusion, inj. Paracetamol 100ml i.v. infusion with closed system standard quality., inj. levofloxacin 100ml i.v. infusion, inj. Linezolid 300 ml i.v. Unibag continer with closed system standard quality., Balanced Salt Sol. for Infusion 500ml flexible bags Osmolarity - 295 mOsm/l, Sodium Chloride - 5.26/l, Sodium Gluconate - 5.02/l, Sodium Acetate - 3.68g/l, KCl - 0.37g/l, MgCl2 - 0.30g/l, Elastomeric disposable pump, Mutirate 5, 7 and 12 ml per hr with 300 ml fill volume and 5 micron filter, Elastomeric disposable pump, Mutirate 2, 3 and 5 ml per hr with 300 ml fill volume and 5 micron filter, Elastomeric disposable Pump, Fixed flow rate 5 ml/hr with 300 ml fill volume & 5 micron filter
Contract Date20 Jul 2024
This is an estimated contract date, exact date may vary.
Contract AmountRefer Documents
Banaras Hindu University - BHU Tender Result
Goods
Healthcare and Medicine
GEM
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
Digital Medical X - Ray Films (v2)
Contract Date19 Jul 2024
This is an estimated contract date, exact date may vary.
Contract Amount₹ 25.8 Lac
Banaras Hindu University - BHU Tender Result
Goods
Machinery and Tools
GEM
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
BOQ ITEMS: A Differential Thread Polyaxially Screws must have Cortical fix thread in 4.5 mm diameter & 30 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 4.5 mm diameter & 35 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 4.5 mm diameter & 40 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 4.5 mm diameter & 45 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 4.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 30 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 35 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 40 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body , A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 45 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 30 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 35 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 40 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 30 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 35 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Provide optimal small pupil capabilities ,with a pupil as small as 2 - 3 mm. It provides excellent fundoscopy through a miotic pupil , so you wont miss a single detail.103 / 124 Degree field of view ,0.45 x image magnification ,2.20 x laser spot magnification , 4 mm working distance Excellent wide field views past the vortex Most popular choice for fast undilated screening exams. Supplier Must Have ISO ,IEC Certificate and MD - 42 , Also Authorization from OEM , A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 40 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces ,The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw ,Screw should be 5.5mm Compatible Rod. ,cross link connectors & rod to rod connectors, screw must have a built in Square threaded inni locking mechanism- OEM Should be ISO13485 ,CDSCO & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body , A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 45 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces ,The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw ,Screw should be 5.5 mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Titanium INNI Screws must have Square Shape built in threaded Inni for locking Mechanism, Inni SIZE 9.9 x4.8 mm compatible of Above mention Pedicle Screw OEM Should be ISO CDSCO and USFDA Certified Supplier Should be OEM Authorized Certified and ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 50 mm in length should have alignment Marking Made up of medical grade Titanium OEM Should be ISO CDSCO & USFDA Certified and Should be Manufactured in India Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 60 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body , Pre cut rod 5.5 mm rod with blunt end 70 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 80 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 90 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 100 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 150 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 200 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 250 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 5.5 mm rod with blunt end 500 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size small - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size Medium - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body , A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size Large - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size Extra Large - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 10 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 12 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 14 mm , . Should have compatible with our existing systems - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 16 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 18 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 20 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 22 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 24 mm , . Should have compatible with our existing systems - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 26 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 26 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 30 mm , . Should have compatible with our existing systems - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 10 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 12 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 14 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 16 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 18 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 20 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 22 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 24 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 26 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 28 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 30 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Tapered rod must accommodate 3.5 /4.0 mm lateral mass screw and 5.5 mm differential thread screw - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 30 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 35 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 40 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 45 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 50 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 60 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 70 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 80 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 90 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 100 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 120 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pre cut rod 3.5 mm rod with blunt end 140 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Skin marker pen for thick Marking (gamma sterile) , Level 1 Protection as per ANSI/ AAMI standard/ ISO 13485 - 2016 - OEM Should be ISO & GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, This drape is used for all kind of spinal surgeries & Laminectomies etc. level 4 protection as per ANSI/AAMI standards. Material 50 gsm , SMS polypropylene water repellent sheet Size 1.5 x 3 mm , incise sheet 15x 35 cm , poly sheet lining 1.20 x 1.20 m. Level 1 Protection as per ANSI/ AAMI standard/ ISO 13485 - 2016 - OEM Should be ISO & GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, PEEK TLIF Cage is single component device used to restore height of disc space by Transformational approach and to facilitate lumbar interbody fusion with maintaining physiological lordotic angulation of lumbar spine. The vertical square teeth with Trapezoidal Shape and Height 0.5 mm made of material (Polyetheretherketone , ASTM F2026 - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, USFDS approved Cervical Interbody Fusion devise made of Titanium material should be available with convex anatomy design ,teardrop foot print ,Lateral window for postoperative fusion evaluation ,large axial graft window , leading edge for ease of insertion ,superior and inferior teeth to resist migration and should be available in 1mm height increments starting from 5mm to 12 mm and footprint of 13x14 mm only ,As per Required Size to be Supplied as per PO - OEM Should be CE & USFDA Certified ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 30 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge- Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors- OEM Should be ISO13485 ,CDSCO & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 35 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 40 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 45 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , S Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 50 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 30 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 35 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 40 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 45 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 50 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 30 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 35 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 40 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 45 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 50 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Titanium Grade Peek Spinal Domino Connector Size 10 mm - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Titanium Grade Peek Spinal Domino Connector Size 12 mm - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Titanium Grade Peek Spinal Domino Connector Size 14 mm - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Mesh Cage in a wide variety of diameters , lengths , and styles , Can also be trimmed to specific heights , Triangle Shape in design. Supplier to be supply Mesh Cage on required Size as per PO (8 to 18 ) (L - 20 to 100) - OEM Should be ISO13485 , CDSCO & INDIAN FDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Balloon kyphoplasty is a minimally invasive procedure for treating painful vertebral body fractures on the thoracic or lumbar spine. This surgical therapy stabilizes the spine and relieves pain. Pressure Gauge indicates the pressure of the balloon . Single Balloon Catheter kit Length 16.3 to 19 mm , Maximum Diameter - 16.3 , PSI Rating - 150 - Manufacturers must have CE Certified and Imported Product , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, Balloon kyphoplasty is a minimally invasive procedure for treating painful vertebral body fractures on the thoracic or lumbar spine. This surgical therapy stabilizes the spine and relieves pain. Pressure Gauge indicates the pressure of the balloon . Double Balloon Catheter Kit Length 16.3 to 19 mm , Maximum Diameter - 16.3 , PSI Rating - 150 - Manufacturers must have CE Certified and Imported Product , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
, Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 5 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 6 / 13 MM , - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine ,system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 7 / 13 MM - OEM Should be ISO ,CE , ZED GOLD & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 8 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 9 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 10 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pedicle reduction screw for listhesis correction Die 5.5 rod system length 35 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pedicle reduction screw for listhesis correction Die 5.5 rod system length 45 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - must be USFDA Approved , manufacturer must have ZED certificate & CE certificate from notified body - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pedicle reduction screw for listhesis correction Die 6.5 rod system length 35 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pedicle reduction screw for listhesis correction Die 6.5 rod system length 40 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Pedicle reduction screw for listhesis correction Die 6.5 rod system length 45 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, This type of needle biopsy uses a thin , hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses a wider needle than does fine - needle aspiration. The needle used during a core needle biopsy is a hollow tube that allows the doctor to extract a sample of tissue for testing - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Imported Instrument Full set Compatible with above mentioned pedicle Screws and with Storage Box on loaner Basis , Imported Instrument full set Compatible with above mentioned Lateral mass Screws and with Storage Box on loaner Basis , Saw System - The Saw Hand Piece is light weight and has a tool less attachment for blades. Saw Hand Piece is Autoclavable. Speed of the Saw Hand Piece is 20 , 000 rpm. Torque of the Saw Hand Piece is 2.5 Nm Charger - two single station chargers , which makes it easy to carry from one OT to another , if required. Battery is Ni - MH Battery , 14.4 Volts. Minimum Run time after each charge is 40 Minutes. Charging time is minimum 1.5 Hrs. . There are 2 batteries provided with each hand piece.OEM Should be ISO , CDSCO Certified , Supplier Should be Provide 5 yr. CMC , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, Quick bone healing and Quick setting calcium hydroxyapatite injectable cement sets in 10 - 20 minutes. This cement acts as osteoinductive material and promotes bone healing it helps in conduction of new bone formation. This cement include with dish , syringe , spatula and 14 gauge needle provided with in the packet Size 5 Gram - OEM Should be ISO , GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body, It has outer surface , it prevents slipping of cage and induces better osteon - integration. Thereby creating better fusion of vertebral bodies. It also prevent subsequent migration of spinal cage. Surface have honeycomb structure. Each cage is pre - filled with hydroxyapatite , by creeping substitution the bone will grow into the spinal cage. Further improving integration with vertebral body bone. Making it a natural part of the spine , Highly polished entry point for easier placement Size 6 angle x 12 mm - OEM Should be ISO & GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
Contract Date19 Jul 2024
This is an estimated contract date, exact date may vary.
Contract Amount₹ 1.9 Cr
Banaras Hindu University - BHU Tender Result
Civil And Construction...+1Pipe Line Project
Eprocure
Result Stage: Awarded (AOC Available)
Varanasi, Uttar Pradesh
Supply And Installation Of Underground Pipeline For Irrigation Purpose In Newly Developed Agriculture Land Behind Power House At Agriculture Research Farm, Bhu
Contract Date19 Jul 2024
Contract Amount₹ 5 Lac
81-90 of 1374 active Tender Results