Wood Tenders
Wood Tenders
Philippine Merchant Marine Academy Tender
Others
Philippines
Details: Description Quantity Unit Item Description 1 Lot Procurement Of Integrated Full Mission Bridge And Engine Room Simulator With Desktop Station Full Mission Bridge Simulator (fmbs) And Mini Bridge Stations’ Features And Applications, Major Components, Bridge Simulator Performance Standards And Hardware 1. Major Components The Full Mission Bridge Simulators That Can Be Integrated With Engine Simulators Shall Consist Of The Following Major Components: A. One (1) Full Mission Bridge Station With 270° Horizontal Display (class A Configuration); B. Seven (7) Mini Bridge Stations With 120° Horizontal Display (class B Configuration); C. One (1) Server Station; D. One (1) Instructor Station; E. One (1) Simulator Scenario Development Station; And F. One (1) Briefing/ Debriefing Station. 2. Features And Applications 2.1 The Bridge Simulator Should Provide A Realistic, Ship-like Environment Based On Real Hardware Consoles And High-quality Visualization. The Systems Include Major Components Such As Conning, Radar/ Arpa And Ecdis, Gmdss, Navigation Equipment, Bearing Finder, Steering Control Console, Engine Control, Auto Pilot System, Overhead Display, Etc. 2.2 The Bridge Simulator Product Shall Be Certified And Compliant As Class A (full Mission), B (multi-task), C (limited Task), And D (cloud-based Distant Learning) Type-approved Maritime Simulator System By An Internationally Recognized Classification Society. The Compliance With Classification Shall Be Reflected In The Certificate Of The Product. 2.3 The Simulator Can Be Utilized To A Variety Of Navigation Techniques Under Different Environmental Conditions, Serving A Wide Range Of Purposes As Follows: 1. Control Of The Ship While Navigating In The Operational And Emergency Modes In Various Weather Conditions With The Possibility Of Setting Wind And Current Parameters; 2. Analysis Of The Above-water Situation In Day And Night Conditions; In Poor Visibility By Visible Navigation Lights And Information Received From Radar/ Arpa; 3. Use Of The Electronic Chart-based Navigational Information System (ecdis); 4. Practical Use Of Radio Equipment And Global Maritime Distress And Safety System (gmdss) Facilities; 5. Application Of The International Regulations For Preventing Collisions At Sea; 6. Ship Control During Anchoring And Mooring; 7. Ship Control During Towing Operations; 8. Ship Control During Maneuvers "man Overboard"; 9. Rational Methods Of Ship Control In Case Of Main Engines (me) And Ship And Navigation Equipment Failures During Movement; 10. Eye Survey Of Above-water And Radar Situation, Determination Of Vessel Movement Elements; 11. Navigational Situation Assessment By Visual Observation During Daytime, By Lights At Night Time And By Observation Of Transmission Of Echo Signals On Ppi Simulators In Conditions Of Limited Visibility; 12. Visual Determination Of Vessel Movement Patterns, Maneuvering Capabilities And Dimensions; 13. Selection And Execution Of Collision Avoidance Maneuvers In Open Sea, During Night And In Limited Visibility Conditions Using Radar/arpa; 14. Evaluation Of Accuracy Of Primary And Secondary Information Received From Arpa, Consideration Of Factors Affecting Accuracy Of Arpa And Delay In Formation Of Secondary Radar Information; 15. Orientation Of Ships In Complex Navigation Conditions In Daytime And Nighttime And In Conditions Of Limited Visibility; 16. Use Of Ecdis For Preliminary And Executive Plotting, Practicing Correct Response To Emergency Signals Produced By Ecdis, Solution Of Chart-metric Tasks And Ensuring Safety Of Navigation With The Use Of Information Received From Ecdis; 17. Use Of Basic Capabilities Of Marine Mobile Service And Marine Mobile Satellite Service. 2.4 The Bridge Simulator Product Shall Be Able To Address The Following Stcw Competencies And Shall Be Reflected In The Certificate. · Table A-ii/1.1 - Plan And Conduct A Passage And Determine Position. • Table A-ii/1.2 - Maintain A Safe Navigational Watch. • Table A-ii/1.3 - Use Of Radar And Arpa To Maintain Safety Of Navigation. § Table A-ii/1.4 - Use Of Ecdis To Maintain The Safety Of Navigation. • Table A-ii/1.5 - Respond To Emergencies. • Table A-ii/1.6 - Respond To A Distress Signal At Sea. • Table A-ii/1.8 - Transmit And Receive Information By Visual Signaling. • Table A-ii/1.9 - Manoeuvre The Ship. • Table A-ii/2.1 - Plan A Voyage And Conduct Navigation. • Table A-ii/2.2 - Determine Position And The Accuracy Of Resultant Position Fix By Any Means. • Table A-ii/2.3 - Determine And Allow For Compass Errors. • Table A-ii/2.4 - Co-ordinate Search And Rescue Operations. • Table A-ii/2.5 - Establish Watchkeeping Arrangements And Procedures. • Table A-ii/2.6 - Maintain Safe Navigation Through The Use Of Information From Navigation Equipment And Systems To Assist Command Decision-making. • Table A-ii/2.7 - Maintain The Safety Of Navigation Through The Use Of Ecdis And Associated Navigation Systems To Assist Command Decision Making. • Table A-ii/2.10 - Maneuver And Handle A Ship In All Conditions. • Table A-ii/2.11 - Operate Remote Controls Of Propulsion Plant And Engineering Systems And Services. • Table A-ii/3.1 - Plan And Conduct A Coastal Passage And Determine Position. • Table A-ii/3.2 - Maintain A Safe Navigational Watch. • Table A-ii/3.3 - Respond To Emergencies. • Table A-ii/3.4 - Respond To A Distress Signal At Sea. • Table A-ii/3.5 - Manoeuvre The Ship And Operate Small Ship Power Plants. • Table A-ii/4.1 - Steer The Ship And Also Comply With Helm Orders In The English Language. • Table A-ii/4.2 - Keep A Proper Look-out By Sight And Hearing. § Table A-ii/5.2 - Contribute To Berthing, Anchoring And Other Mooring Operations. • Table A-v/4-1.1 - Contribute To Safe Operation Of Vessels Operating In Polar Waters. • Table A-v/4-1.2 - Monitor And Ensure Compliance With Legislative Requirements. • Table A-v/4-1.3 - Apply Safe Working Practices, Respond To Emergencies. • Table A-v/4-1.4 - Ensure Compliance With Pollution-prevention Requirements And Prevent Environmental Hazards. • Table A-v/4-2.1 - Plan And Conduct A Voyage In Polar Waters. • Table A-v/4-2.2 - Manage The Safe Operation Of Vessels Operating In Polar Waters. • Table A-v/4-2.3 - Maintain Safety Of The Ship's Crew And Passengers And The Operational Condition Of Life- Saving, Firefighting And Other Safety Systems. 2.5 The Bridge Simulator Shall Allow For Training And Certification Of Watch Officers, Chief Officers, Captains, And Pilots Serving On Commercial And Fishing Vessels Of 500 Gross Tonnage Or More In Accordance With The Requirements Of The Imo Stcw Convention And Model Courses: · 1.07 – Radar Navigation, Radar Plotting And Use Of Arpa; · 1.08 – Radar, Arpa, Bridge Teamwork And Search & Rescue; · 1.22 – Ship Simulator And Bridge Teamwork; · 1.27 – Operational Use Of Electronic Chart Display And Information System (ecdis); · 1.32 – Operational Use Of Integrated Bridge System; · 1.34 – Operational Use Of Ais; · 2.02 – Maritime Sar Coordinator; · 3.11 – Marine Accident And Incident Investigation With Compendium; · 3.19 – Ship Security Officer; · 3.23 – Actions To Be Taken To Prevent Acts Of Piracy And Armed Robbery; · 7.01 – Master And Chief Mate; · 7.03 – Officer In Charge Of Navigational Watch; · 7.05 – Officer In Charge Of Navigational Watch Of Fishing Vessel; · 1.25 – General Operator’s Certificate For The Gmdss; · 1.26 – Restricted Operator’s Certificate For The Gmdss. 2.6 The Bridge Simulator Shall Have All The Ownship Models, Target Ship Models , Objects And Exercise Areas Available In The Database Of The Simulator Product. It Shall Also Include Polar Areas, The Existing Models And Areas In Current Simulator, Naval And Coast Guard Ship Models, Ship Models Ready For Integration With Engine Simulators And Ship/engine Models Using Future Fuels. 2.7 The Simulator Shall Have Intercom Installed In The Instructor Station And All Bridge Stations. 2.8 The Simulator Shall Have An Evaluation And Assessment Method Designed For The Evaluation And Assessment Of A Range Of Predefined Assessment Parameters From The Following Categories: • Planning And Conducting A Passage And Determine Position; • Maintain Safe Navigational Watch; • Using Radar And Arpa To Maintain Navigational Safety; • Ability To Operate And Analyze Information Obtained From Arpa; • Respond To Emergencies; • Use Imo Standard Marine Communication Phrases And Use English Inwriting And Speaking; • Transmit And Receive Information Using Visual Signals; • Maneuver The Ship; • Colreg. 2.9 The Simulator Shall Have The Ability To Set Up A Scoring And Grading System To Evaluate The Operator’s Performance. The Program Allows The Instructor To Monitor The Results Of The Bridge Team / Operator Workstation Performance. 2.10 The Simulator Shall Be Capable Of Simulating Ship Operation In Polar Waters Or Ice Navigation According To The Polar Code And Shall Have The Following Training Capabilities: - Ice Management Of Offshore Installations In An Arctic Environment, - Use Of Radar Data And Ice Charts In Ecdis While Navigating In Ice Conditions, - Following Of Icebreakers, - Offshore Loading Operations To Include Mooring To Single Point Mooring And Floating Production Storage And Offloading Equipment In Ice Conditions, And - Navigation In Shattered Ice, Along Hard Ice Edges, Bumping Against Ice Edges, In Open Pack Ice, In Ice Holes, And Spots Of Ice-free Water. 2.11 The Ice Navigation Environment Shall Have The Following Characteristics: - Capable Of Ice Accumulation On Ship Superstructure, - Ship’s Tracks On Ice Fields Re-freeze As Programmed By The User, - Ice Mounds And Channels Can Be Added By The User, - Characteristics Of Ice Resistance Are Based On The Type Of Ice, Thickness, And Accumulation, - Capable Of Traversing Large Ice Areas, And - Realistic Representation Of Iceberg Objects. 3. Bridge Simulator Performance Standards 3.1 Physical Realism The Bridge Simulator Stations Shall Have The Following Physical Realism: A. The Equipment, Consoles, And Workstations Shall Be Installed, Mounted, And Arranged In A Manner That Mimics An Actual Bridge Of A Ship. B. The Workstations Shall Have Standard Rubber Mat Flooring. The Simulator Shall Have The Following Equipment: C. Controls Of Propulsion Plant Operations, Including Engine Telegraph, Pitch-control And Thrusters. There Shall Be Indicators For Shaft(s) Revolutions And Pitch Of Propeller(s). There Shall Be Controls For At Least One Propeller And One Bow Thruster. D. Controls Of Propulsion Plant For Mooring Operations. By Any Method, It Shall Be Possible To Observe The Ship's Side And The Dock During Operation Of Such Controls. E. Controls Of Auxiliary Machinery. There Shall Be Controls For At Least Two Auxiliary Engines, Including Electric Power Supply Control. F. Steering Console, Including Equipment For Hand Steering And Automatic Steering With Controls For Switchover. There Shall Be Indicators Of Rudder Angle And Rate Of Turn. G. Steering Compass And Bearing Compass (or Repeater) With An Accuracy Of At Least 1 Degree. H. At Least One Radar/arpa Display/unit (automatic Radar Plotting Aid). It Shall Be Possible To Simulate Both A 10 Cm (s-band) And A 3 Cm (x-band) Radars. The Radar Shall Be Capable To Operate In The Stabilised Relative-motion Mode And Sea- And Ground-stabilised True-motion Modes (see Stcw Section A-1/12.4.1 And 1/12.5 And Paragraph 2 Of Section B-i/12). I. Communication Equipment Per Gmdss (global Maritime Distress Safety System) Framework, Covering At Least The Requirements For The Relevant Area. J. The Simulator Shall Include A Communications System That Will Allow For Internal Ship Communications To Be Conducted. K. Ecdis (electronic Chart Display And Information System) Displaying Selected Information From A System Electronic Navigational Chart (senc) With Positional Information From Navigation Sensors Like Ais And Radar To Assist The Mariner In Route Planning And Route Monitoring, And By Displaying Additional Navigation-related Information. (see Stcw Section B-i/12). L. Gps (global Positioning System), Echo-sounder And Speed Log Showing Speed Through The Water (1 Axis) For Ships Below 50,000 Grt And In Addition Speed And Distance Over Ground In Forward And Athwart Ship Direction For Ships Above 50,000 Grt. M. Instrument (anemometer) For Indication Of Relative Wind- Direction And Force. N. Ship Sound Signal Control Panel According To Colreg. O. Instrument For Indication Of Navigational Lights. P. Function For Transmitting Visual Signals (morse Light). Q. Control System For General Alarm And Fire Detection/alarm And Other Alarms. R. Ais (automatic Identification System). S. Ship-borne Meteorological Instrument. The Simulator Shall Have The Following Additional Requirements For Training In Ice Navigation: T. Controls For Propulsion Plant Operations, Including Engine Telegraph, Pitch Control, And Thrusters. There Shall Be Indicators For Shaft Revolutions And Pitch Of Propeller. There Shall Be Controls For At Least One Propeller And One Bow Thruster. U. Two Speed And Distance Measuring Devices. Each Device Should Operate On A Different Principle, And At Least One Device Should Be Capable Of Being Operated In Both The Sea And The Ground Stabilized Mode. V. Searchlight Controllable From Conning Positions. W. Manually Operated Flashing Red Light Visible From Astern To Indicate When The Ship Is Stopped. X. Vdr (voyage Data Recorder) Or Capability For Vessel History Track And Learner Actions Log From The Instructor And The Assessor Position. Y. Equipment Capable Of Receiving Ice, Icing Warnings, And Weather Information Charts. Z. Anchoring And Towing Arrangements. The Simulator Shall Have The Following Additional Requirements For Training In Integrated Bridge Systems Including Integrated Navigation Systems: Aa. Workstation For Navigating, Maneuvering And Monitoring Consisting Of: · Radar/arpa · Ecdis · Conning Display · Binoculars Control · Autopilot Control · Observer Position/ Visual Control · Information On Position-fixing Systems · Information On Ship Automatic Identification System (ais) · Heading Control System · Flags, Daytime Shapes And Sound Signals · Control For The Main Engine Including Emergency Stop · Control For The Main Rudder Using Helm · Controls For Thruster · Two-way Vhf Radiotelephone (walkie-talkie) With Charging Connection · Internal Communication Equipment · Public Address System · Vhf With Channel Selector · Remote Control For Searchlight · Rudder Pump Selector Switch · Steering Mode Selector Switch · Steering Position Selector Switch · Illumination Of Equipment And Displays In The Surrounding Darkness · Sound Reception System · Acknowledgment Of The Watch Alarm · Controls For Console Lighting · Indicators For: - Propeller Revolutions (actual And Desired) - Main Engine Revolution In The Case Of Reduction Geared Engine - Propeller Pitch In The Case Of Controllable Pitch Propeller - Torque - Starting Air - Lateral Thrust - Speed - Rudder Angle - Rate-of-turn - Gyro Compass Heading - Magnetic Compass Heading - Heading Reminder (pre-set Heading) - Water Depth Including Depth Warning Adjustment - Time - Wind Direction And Velocity - Air And Water Temperature - Clinometer - Alarms · Signal Transmitter For: - Whistle - Automatic Device For Fog Signals - Alarms, (general Alarm, Emergency Alarm, Etc.) - Morse Signaling Light Bb. Workstation For Manual Steering (wheelhouse) Consisting Of: · Steering Wheel · Rudder Pump Selector Switch · Indications For: - Gyro Compass Heading - Magnetic Compass Heading - Pre-set Heading - Rudder Angle - Rate Of Turn Cc. Workstation For Planning And Documentation Consisting Of: · Ecdis Including Navigation Planning Station · Route Planning Devices · Chart Table · Paper Charts · Plotting Aids Dd. Workstation For Communications Consisting Of: · Gmdss Equipment As Required For The Applicable Sea Area · Vhf-dsc, Radiotelephone · Mf-dsc, Radiotelephone · Mf/hf-dsc, Nbdp, Radiotelephone · Mf/hf Mf/hf Radio Telex · Inmarsat-ses, Egc Rx With Lrit And Ssas · Navtex/egc/hf Direct Printing Telegraph · Fbb/iridium · Cospas-sarsat Epirb · Sart · Ais Sart · Main Station For Two-way Vhf Radiotelephone · Aircraft Vhf Radiotelephone · Gmdss Alarm Panel · Radio Direction Finder Rt-500-m (marine) · Power Switchboard · Battery Charger · Virtual Printer Ee. All Systems Related To The Integrated Bridge System Shall Include Failure Control(s) And Method(s) To Train And Assess The Learner In The Use Of Advanced Equipment, Technology And Enable Familiarization And Training To Understand The Limitations Of Automatic Systems. 3.2 Behavioral Realism The Bridge Simulator Stations Shall Have The Following Behavioral Realism: A. The Simulation Of Ownship Shall Be Based On A Mathematical Model With 6 Degrees Of Freedom. B. The Model Shall Realistically Simulate Own Ship Hydrodynamics In Open Water Conditions, Including The Effects Of Wind Forces, Wave Forces, Tidal Stream And Currents. C. The Model Shall Realistically Simulate Own Ship Hydrodynamics In Restricted Waterways, Including Shallow Water And Bank Effects, Interaction With Other Ships And Direct, Counter And Sheer Currents. D. The Simulator Shall Include Mathematical Models Of Different The Types Of Ownships. E. The Simulator Shall Include Tug Models That Can Realistically Simulate Tug Assistance During Maneuvering And Escort Operations. It Shall Be Possible To Simulate Pull, Push, Reposition Towing And Escorting. F. The Simulator Shall Include Exercise Areas Including Correct Data For Landmass, Depth, Buoys, Tidal Streams And Visual As Appropriate To The Nautical Chart And Publication Used For The Relevant Training Objectives. G. The Radar Simulation Equipment Shall Be Capable Of Model Weather, Tidal Streams, Current, Shadow Sectors, Spurious And False Echoes And Other Propagation Effects, And Generate Coastlines, Navigational Buoys And Search And Rescue Transponders. H. The Arpa Simulation Equipment Shall Incorporate The Facilities For: - Manual And Automatic Target Acquisition - Fast Track Information - Use Of Exclusion Areas - Vector/graphic Time-scale And Data Display - Trial Maneuvers. I. The Ecdis Simulation Equipment Shall Incorporate The Facilities For: - Integration With Other Navigation Systems - Own Position - Sea Area Display - Mode And Orientation - Chart Data Displayed - Route Monitoring - User-created Information Layers - Contacts (when Interfaced With Ais And/or Radar Tracking) - Radar Overlay Functions. J. The Simulator Shall Provide An Own Ship Engine Sound, Reflecting The Power Output. K. The Simulator Shall Provide Capabilities For Realistically Conduct Anchoring Operations. L. The Model Shall Realistically Simulate Own Ship Hydrodynamics In Interaction With Applicable Anchor And Chain Dimensions With Different Bottom Holding Grounds, Including The Effects Of Wind Forces, Wave Forces, Tidal Stream And Currents. M. The Simulator Shall Provide Capabilities For Realistically Simulate The Function Of Mooring And Tug Lines And How Each Line Functions As Part Of An Overall System Taking Into Account The Capacities, Safe Working Loads, And Breaking Strengths Of Mooring Equipment Including Mooring Wires, Synthetic And Fiber Lines, Winches, Anchor Windlasses, Capstans, Bitts, Chocks And Bollards. The Simulator Shall Have The Following Additional Requirements For Training In Ice Navigation: N. The Own Ship Model Shall Realistically Simulate Hydrodynamics In Interaction With Solid Ice Edge. O. The Own Ship Model Shall Realistically Simulate Hydrodynamics And Ice Pressure In Interaction With Solid And Packed Ice. Ship Motion In Solid Ice Should Affect At Least Ship Speed And Turning Radius. P. The Own Ship Model Shall Realistically Simulate The Effects Of Reduced Stability As A Consequence Of Ice Accretion. Q. It Shall Be Possible To Simulate The Effect Of The Following Ice Conditions With Variations: - Ice Type - Ice Concentration - Ice Thickness. R. It Shall Be Possible To Realistically Simulate The Towing Of Ownship – Ownship, And Own Ship Target Ship And Target Ownship. It Shall Be Possible To Introduce Different Towing Gear Like Rope Or Steel Wire With Different Strength And Elasticity, Forward, Stern And Side Towing. S. It Shall Be Possible To Realistically Simulate The Interaction Between The Ships Propeller Wash And The Ice. T. It Shall Be Possible To Realistically Simulate Ice Drift. U. The Simulator Shall Be Equipped With Iceberg Targets Of At Least Six Different Sizes Including Realistic Underwater Bodies Which Interacts With The Sea Bottom. The Icebergs Should Be Visible On The Ship's Radar. V. Motion Through Ice Hummocks Should Be Simulated Realistically Considering Ship Icebreaking Capabilities And Affect Ship's Speed, Roll And Pitch. The Simulator Shall Have The Following Additional Requirements For Training In Integrated Bridge Systems Including Integrated Navigation System: W. The Integrated Navigation System Should Combine Process And Evaluate Data From All Sensors In Use. The Integrity Of Data From Different Sensors Should Be Evaluated Prior To Distribution. X. The Integrated Navigation System Shall Ensure That The Different Types Of Information Are Distributed To The Relevant Parts Of The System, Applying A Consistent Common Reference System For All Types Of Information. Y. The Integrated Navigation System Shall Provide Information On Position, Speed, Heading, And Time. Z. The Integrated Navigation System Shall Be Able To Automatically, Continually And Graphically Indicate The Ship's Position, Speed And Heading And, Where Available, Depth In Relation To The Planned Route As Well As To Known And Detected Hazards. Aa. The Integrated Navigation System Shall, In Addition, Provide Means To Automatically Control Heading, Track Or Speed, And Monitor The Performance And Status Of These Controls. Bb. Alarms Shall Be Displayed So That The Alarm Reason And The Resulting Functional Restrictions Can Be Easily Understood. 3.3 Operating Environment The Bridge Simulator Shall Exhibit The Following Operating Environment: A. The Simulator Shall Be Able To Present Different Types Of Target Ships, Each Equipped With A Mathematical Model, Which Accounts For Motion, Drift And Steering Angles According To Forces Induced By Current, Wind Or Wave. B. The Targets Shall Be Equipped With Navigational And Signal-lights, Shapes, And Sound Signals, According To Rules Of The Road. The Signals Shall Be Individually Controlled By The Instructor, And The Sound Signals Shall Be Directional And Fade With Range. Each Ship Shall Have An Aspect Recognizable At A Distance Of 6 Nautical Miles In Clear Weather. A Ship Underway Shall Provide Relevant Bow- And Stern Wave. C. The Simulator Shall Be Equipped With Targets Enabling Search And Rescuing Persons From The Sea, Assisting A Ship In Distress And Responding To Emergencies Which Arise In Port. Such Targets Shall At Least Be: · Rocket Parachute Flares · Hand Flares · Buoyant Smoke Signals · Sart (search And Rescue Transponder) · Satellite Epirb (emergency Position Indicating Radio Beacon) · Lifeboat · Life Raft · Rescue Helicopter · Rescue Aircraft · People In Water. D. The Simulator Shall Be Able To Present At Least 20 Target Ships At The Same Time, Where The Instructor Shall Be Able To Programme Voyage Routes For Each Target Ship Individually. (see Stcw Section A-1/12.4.3) E. The Simulator Shall Provide A Realistic Visual Scenario By Day, Dusk Or By Night, Including Variable Meteorological Visibility, Changing In Time. It Shall Be Possible To Create A Range Of Visual Conditions, From Dense Fog To Clear Conditions. F. The Visual System And/or A Motion Platform Shall Replicate Movements Of Own Ship According To 6 Degrees Of Freedom. G. The Projection Of The View Shall Be Placed At Such A Distance And In Such A Manner From The Bridge Windows That Accurate Visual Bearings May Be Taken To Objects In The Scene. It Shall Be Possible To Use Binocular Systems For Observations. H. The Visual System Shall Present The Outside World By A View Around The Horizon (360°). The Horizontal Field Of View May Be Obtained By A View Of 270° And Where The Rest Of The Horizon May Be Panned (to Move The “camera”). (applicable Only To Full Mission Bridge Station With 270° Horizontal Display) I. The Visual System Shall Present The Outside World By A View Of At Least 120° Horizontal Field Of View. In Addition, At Least The Horizon From 120° Port To 120° Starboard Shall Be Able To Be Visualised By Any Method. (applicable Only To Mini Bridge Station With 120° Horizontal Display). J. The Visual System Shall Present A Vertical View From The Workstations For Navigation, Traffic Surveillance And Manoeuvring Enabling The Navigator To Detect And Monitor Objects Visually On The Sea Surface Up To The Horizon Within The Required Horizontal Field Of View When The Ship Is Pitching And Rolling. In Addition, By Any Method, It Shall Be Possible To Observe The Ship's Side And The Dock During Mooring Operations. K. The Visual System Shall Present All Navigational Marks According To Charts Used. L. The Visual System Shall Show Objects With Sufficient Realism (detailed Enough To Be Recognized As In Real Life). M. The Visual System Shall Show Mooring And Towing Lines With Sufficient Realism In Accordance With The Forces Effecting The Tension. N. The Visual System Shall Provide A Realistic Set Of Bow Wave, Sea Spray And Wakes In Accordance With Ships Power Output, Speed And Weather Conditions. O. The Visual System Shall Provide A Realistic Set Of Flue Gas Emission And Waving Flag Effect In Accordance With Ships Power Output, Speed And Weather Conditions. P. The Simulator Shall Be Capable Of Providing Environmental Sound According To Conditions Simulated. Q. The Navigated Waters Shall Include A Current Pattern, Changeable In Time, According To The Charts Used. Tidal Waters Shall Be Reflected. R. The Simulation Shall Include The Depth According To Charts Used, Reflecting Water Level According To Tidal Water Situation. S. The Simulator Shall Provide At Least Two Different Wave Spectra, Variable In Direction Height And Period. T. The Visual System Shall Provide A Realistic Set Of Wind Waves Including White Caps According To The Beaufort Wind Force Scale. The Simulator Shall Have The Following Additional Requirements For Training In Ice Navigation: U. The Visual System Shall Be Capable Of Showing Concentrations Of Solid And Broken Ice Of Different Thickness. V. The Visual System Shall Be Capable Of Showing The Result Of Icebreaking Including Opening, Twin Breaking And Compacting Channel. W. The Visual System Shall Be Capable Of Showing The Effects Of Searchlight. X. The Visual System Shall Be Capable Of Showing The Effects Of The Ice Accretion To The Own Ship Model. The Simulator Shall Have The Following Additional Requirements For Training In Integrated Bridge Systems Including Integrated Navigation Systems: Y. There Shall Be A Field Of View Around The Vessel Of 360° Obtained By An Observer Moving Within The Confines Of The Wheelhouse Or May Be Panned (to Move The Camera). 4. Hardware Requirements 1 Set 4.1 Full Mission Bridge Simulator (horizon Field View Of 270 Degrees) A. Steel Fabrication Of Main Bridge Consoles Consisting Of: I. Conning/maneuvering Console Ii. Radar Console Iii. Ecdis Console Iv. Bearing Console V. Navigation Aid Equipment Console Vi. Gmdss Console Vii. Steering Stand/console Viii. Chart Table Ix. Overhead Panel X. Gyro Repeater With Pelorus Stand Xi. Binoculars Xii. The Console Must Made Of Steel W/ Handrails B. Visual Specification (minimum Requirements) I. 9x 70” Visual Screens Led Backlit 1. Pc Visual Channel 2. Intel Core I5 Processor 3. 16 Gb Ram 4. 256 M.2 Ssd 5. Rtx 4070 Or Higher 6. Keyboard/mouse 7. Hdmi Cable 8. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator C. 1x Conning Console (minimum Requirements) 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2 Ssd 4. 2x Monitor 24” 5. Keyboard/mouse 6. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator 7. Console Made Of Steel (tct 0.8 Mm To 2 Mm) 8. Instrument Adds On Conning Console. D. 2x Ecdis Console (minimum Requirements) 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2 Ssd 4. Monitor 24” 5. Keyboard/mouse 6. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator 7. Console Made Of Steel (tct 0.8 Mm To 2 Mm) E. 2x Radar / Arpa Console (minimum Requirements) 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2 Ssd 4. Monitor 24” 5. Keyboard/mouse 6. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator 7. Console Made Of Steel (tct 0.8 Mm To 2 Mm) F. Binocular And Instrument (minimum Requirements) 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2. Ssd 4. Rtx 4070 Or Higher 5. Keyboard/mouse 6. 2x 24" Monitor 7. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator 8. Console Made Of Steel (tct 0.8 Mm To 2 Mm) G. Overhead Panel Display 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2 Ssd 4. At Least 1width And 0.4height 5. Keyboard/mouse 6. Ups 1kva A. Surge Protection B. W/ Automatic Voltage Regulator H. Radar/arpa I. Radar/arpa Keyboard (1 Set) Specifications: 1. Usb Interface 2. Console Mount Type I. Handset I. Handset Includes: 1. Handset 2. Cradle With A Ptt Switch 3. Usb Interface Board 4. Handset Box J. 1x Chart Table Console 1300mm X 1312mm (minimum Requirements) 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2 Ssd 4. 2x Monitor 24” 5. Keyboard/mouse 6. Ups 1kva A. Surge Protection B. W/ Automatic Voltage Regulator Ii. 1x Parallel Ruler Iii. 1x One-hand Compass Divider Steel Iv. 10x Plotting Triangle With Handle V. 1x Deck Log Book Vi. 1x Night Order Book Vii. 1x Bell Book Viii. 1x Chronometer Ix. Admiralty Paper Charts Related To Installed Maps In Simulator K. Gyro Repeater With Pelorus Stand 1. Bearing Repeater Compass 2. Pelorus Stand 3. Power: 24vd 4. Signal: Rs422 Nmea L. Weather Instruments 1. 1x Ships Clock 2. 1x Aneroid Barometer 3. 1x Hygrometer. M. Speaker With Subwoofer I. Channel Sound System Specification: 1. Interface With Visual Pc 2. Realization Of 3d Sound Effect System 3. Atleast 450watts Speaker With Subwoofer 4. Port: Mini Jack 7 Sets 4.2 Mini Bridge Simulator (horizon Field View Of 120 Degrees) A. Consoles Made In Formica Laminated Board Fabrication Of Main Bridge Consoles Consisting Of: I. Conning Console Ii. Radar Console Iii. Ecdis Console Iv. Maneuvering Console V. Chart Table With Gooseneck Dimming Light B. Mini Bridge Desktop Station (bridge Image Generator Computer For Visual, Conning, Radar, Maneuvering And Overhead Display) I. 3x 45” 4k Display For Visual (minimum Requirements) Ii. 1x Computer (minimum Requirements) 1. 256 M.2 Ssd 2. Rtx 4070 Or Higher 3. 1 X Keyboard/mouse 4. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator Iii. 1 X Computer (minimum Requirements) 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2 Ssd 4. Keyboard/mouse 5. 24” Monitor 6. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator Iv. 1 X Overhead Panel Display V. 1 X Speakers (minimum Requirements) 1. Interface With Visual Pc 2. Realization Of 3d Sound Effect System 3. Atleast 150 Watts Speaker With Subwoofer 4. Port: Mini Jack Vi. 1 X Goose Neck Microphone Vii. 1 X Set Desktop Instrument Console Including: 1. Steering System / Autopilot / Nfu 2. Steering Wheel Viii. Dual Telegraph 1. 1 X Console Tables 2. 1 X Handheld Uhf Equipment 3. 1 X Console Made In Formica Laminated Board (tct 3/4 Inches) Ix. Chart Table And Plotting Aids (minimum Requirements) 1. Intel Core I5 Processor 2. 8 Gb Ram 3. 256 M.2 Ssd 4. 1x Monitor 24” 5. Keyboard/mouse 6. Ups 1kva A. Surge Protection B. W/ Automatic Voltage Regulator X. 1x Parallel Ruler Xi. 1x One-hand Compass Divider Steel Xii. 1x Plotting Triangle With Handle Xiii. 1x Chart Table At Least 1000mm X 700mm Xiv. 1x Deck Log Book Xv. 1x Night Order Book Xvi. 1x Bell Book Xvii. 1x Chronometer 1 Set 4.3 Bridge Instructor Station A. Instructor Station I. 1x Computer (minimum Requirements) 1. 2x 24” Monitor 2. Intel Core I5 Processor 3. 16 Gb Ram 4. 256 M.2 Ssd 5. Rtx 4070 Or Higher 6. Keyboard/mouse 7. Ups 1.5kva 1. Surge Protection 2. W/ Automatic Voltage Regulator Ii. 1x Handset 1. Handset 2. Cradle With A Ptt Switch 3. Usb Interface Board 4. Handset Box Iii. 1x Speaker 1. Type: Desktop 2. Port: Mini Jack Iv. 1x Steel Cabinet W/ Lock 1. Metal Drawer Office Drawer 2. File Cabinet Storage With Wheel V. 1x Drone View Monitor W/ Smart Tv 55” Tv Led (environment View Of Instructor) Vi. 1x Smart Tv 55” Tv Led For Cctv Vii. 1x Printer 1. Laser Printer A4 2. A4 Print Speed Up To 48 Ppm 3. Auto 2-sided (duplex) Printing, 1-line Lcd 4. Wifi, Airprint, Mopria, Wifi Direct, Lan, Usb 2.0 5. Colored Printer Viii. Instructor Station Table Specification: Ix. 1x Table Size: At Least L 1700 X W 700 X H 750 Mm 1. Material: Formica Matt Laminate On Chipboard X. Intercom Telephone / Public Announcement System Xi. 9x Two-way Vhf Radiotelephone (walkie-talkie) With Charging Connection Xii. 1x Ergodynamic Chair Xiii. 1x Document Metal Cabinet With Glass Sliding Door 1. Size: 1850x 400mmx 900mm 2. Door Lock 1 Set 4.4 Bridge Simulator Scenario Development Station B. Scenario Development Station As An Instructor Station Capable Of Deploying Scenarios To Other Stations. I. 1x Computer (minimum Requirements) 1. 2x 24” Monitor 2. Intel Core I5 Processor 3. 16 Gb Ram 4. 256 M.2 Ssd 5. Rtx 4070 Or Higher 6. Keyboard/mouse 7. Ups 1.5kva 1. Surge Protection 2. W/ Automatic Voltage Regulator Ii. 1x Table Size: At Least L 1200 X W 800 X H 750 Mm 1. Material: Formica Matt Laminate On Chipboard Iii. 1x Ergodynamic Chair 5. Software Requirements 5.1 Full Mission Bridge Simulator The Full Mission Bridge Simulator Shall Have The Following Software And Controls For The Following Workstations: A. Workstation For Navigating, Maneuvering And Monitoring Consisting: · One (1) Ecdis Master Software · One (1) Ecdis Slave Software · One (1) Conning Display Software · One (1) Radar/arpa 3cm · One (1) Radar/arpa 10cm · Nine (9) Realistic Visualization Software With 270° Field Of View · Keyboard And Trackball Controls For Ecdis, Radar Apra And Conning Display · Two (2) Vhf Dsc Radio W Ch16 · One (1) Overhead Panel Display · One (1) Main Engine Telegraph Including Emergency Stop Control With Printer · One (1) Bow And Stern Thruster Control · One (1) Gps Software · One (1) Bridge Navigational Watch Alarm System (bnwas) · One (1) Echo Sounder · One (1) Speed Log · One (1) Vr Binoculars · One (1) Observer Position/ Visual Control · One (1) Anchor Gear And Mooring Operations Control · One (1) Towing Control · One (1) Tugs Control · One (1) Autopilot Control System · Nfu/ Fu Controls · One (1) Tiller Controls · One (1) Information On Ship Automatic Identification System (ais) · One (1) Intercom Telephone Capable For Public Address System · One (1) Conference Microphone · One (1) Control For Searchlight · One (1) Gyro Repeater/pelorus Stand That Can Display Magnetic And Gyro Compass · One (1) Bearing Finder · One (1) Alarm System Panel For General Alarm, Fire Alarm, And Other Alarms · Navigation Lights Control · Flags, Daytime Shapes And Sound Signals Control · One (1) Two-way Vhf Radiotelephone (walkie-talkie) With Charging Connection · Sound Reception System · Acknowledgment Of The Watch Alarm · Information Indicators For: - Propeller Revolutions (actual And Desired) - Main Engine Rpm - Main Engine Revolution In The Case Of Reduction Geared Engine - Propeller Pitch In The Case Of Controllable Pitch Propeller - Torque - Starting Air - Lateral Thrust - Log Speed And Speed Over The Ground - Bow And Stern Speed - Athwartship Speed - Rudder Angle - Rate-of-turn - Gyro Compass Heading - Magnetic Compass Heading - Heading Reminder (pre-set Heading) - Water Depth Including Depth Warning Adjustment - Vessel Time - Wind Direction And Velocity - Air And Water Temperature - Clinometer - Alarms - Pilot Card - Maneuvering Characteristics - Scoring Exercise/ Assessment · Signal Transmitter For: - Whistle - Automatic Device For Fog Signals - Alarms, (general Alarm, Emergency Alarm, Etc.) - Morse Signaling Light B. Workstation For Manual Steering (wheelhouse) Consisting Of: · One (1) Steering Wheel · Rudder Pump Selector Switch · Steering Mode Selector Switch · Steering Position Selector Switch · Indications For: - Gyro Compass Heading - Magnetic Compass Heading - Pre-set Heading - Rudder Angle - Rate Of Turn - Steering Mode (fu/nfu) – Track Control/auto Navigation C. Workstation For Route Planning And Documentation Consisting Of: · Computer For Route Planning Devices (ecdis) · Chart Table With Drawers For Paper Charts, Flags And Pennants · Paper Charts · Plotting Aids · Chronometer · Weather Facsimile D. Workstation For Communications Consisting Of: · One (1) Handset For Radiotelephone · Gmdss Equipment As Required For The Applicable Sea Area · Vhf-dsc, Radiotelephone · Mf-dsc, Radiotelephone · Mf/hf-dsc, Nbdp, Radiotelephone · Mf/hf Mf/hf Radio Telex · Inmarsat-ses, Egc Rx With Lrit And Ssas · Navtex/egc/hf Direct Printing Telegraph · Fbb/iridium · Cospas-sarsat Epirb · Sart · Ais Sart · Main Station For Two-way Vhf Radiotelephone · Aircraft Vhf Radiotelephone · Gmdss Alarm Panel · Radio Direction Finder Rt-500-m (marine) · Power Switchboard · Battery Charger · Virtual Printer 5.2 Mini Bridge Simulator The Mini Bridge Simulators Shall Have Each Of The Following Software And Controls For The Following Workstations: E. Workstation For Navigating, Maneuvering And Monitoring Consisting: · One (1) Ecdis Master Software · One (1) Conning Display Software · One (1) Radar/arpa Interchangeable To 3cm & 10cm · Three (3) Realistic Visualization Software With 120° Field Of View · Keyboard And Trackball Controls For Ecdis, Radar Apra And Conning Display · One (1) Vhf Dsc Radio W Ch16 · One (1) Overhead Panel Display · One (1) Main Engine Telegraph Including Emergency Stop Control With Printer · One (1) Bow And Stern Thruster Control · One (1) Gps Software · One (1) Bridge Navigational Watch Alarm System (bnwas) · One (1) Echo Sounder · One (1) Speed Log · One (1) Vr Binoculars · One (1) Observer Position/ Visual Control · One (1) Anchor Gear And Mooring Operations Control · One (1) Towing Control · One (1) Tugs Control · One (1) Autopilot Control System · Nfu/ Fu Controls · One (1) Tiller Controls · One (1) Information On Ship Automatic Identification System (ais) · One (1) Intercom Telephone Capable For Public Address System · One (1) Conference Microphone · One (1) Control For Searchlight · One (1) Vdr Remote Alarm Panel · One (1) Bearing Finder · One (1) Alarm System Panel For General Alarm, Fire Alarm, And Other Alarms · Navigation Lights Control · Flags, Daytime Shapes And Sound Signals Control · One (1) Two-way Vhf Radiotelephone (walkie-talkie) With Charging Connection · Sound Reception System · Acknowledgment Of The Watch Alarm · Information Indicators For: - Propeller Revolutions (actual And Desired) - Main Engine Rpm - Main Engine Revolution In The Case Of Reduction Geared Engine - Propeller Pitch In The Case Of Controllable Pitch Propeller - Torque - Starting Air - Lateral Thrust - Log Speed And Speed Over The Ground - Bow And Stern Speed - Athwartship Speed - Rudder Angle - Rate-of-turn - Gyro Compass Heading - Magnetic Compass Heading - Heading Reminder (pre-set Heading) - Water Depth Including Depth Warning Adjustment - Vessel Time - Wind Direction And Velocity - Air And Water Temperature - Clinometer - Alarms - Pilot Card - Maneuvering Characteristics - Scoring Exercise/ Assessment · Signal Transmitter For: - Whistle - Automatic Device For Fog Signals - Alarms, (general Alarm, Emergency Alarm, Etc.) - Morse Signaling Light F. Workstation For Manual Steering (wheelhouse) Consisting Of: · One (1) Steering Wheel · Rudder Pump Selector Switch · Steering Mode Selector Switch · Steering Position Selector Switch · Indications For: - Gyro Compass Heading - Magnetic Compass Heading - Pre-set Heading - Rudder Angle - Rate Of Turn - Steering Mode (fu/nfu) G. Workstation For Route Planning And Documentation Consisting Of: · Computer For Route Planning Devices (ecdis) · Chart Table With Drawers For Paper Charts, Flags And Pennants · Paper Charts · Plotting Aids · Chronometer H. Workstation For Communications Consisting Of: · One (1) Handset For Radiotelephone · Gmdss Equipment As Required For The Applicable Sea Area · Vhf-dsc, Radiotelephone · Mf-dsc, Radiotelephone · Mf/hf-dsc, Nbdp, Radiotelephone · Mf/hf Mf/hf Radio Telex · Inmarsat-ses, Egc Rx With Lrit And Ssas · Navtex/egc/hf Direct Printing Telegraph · Fbb/iridium · Cospas-sarsat Epirb · Sart · Ais Sart · Main Station For Two-way Vhf Radiotelephone · Aircraft Vhf Radiotelephone · Gmdss Alarm Panel · Radio Direction Finder Rt-500-m (marine) · Power Switchboard · Battery Charger · Virtual Printer 5.3 Instructor Station 1. The Instructor Workstation Is An Integral Part Of The Simulator And Is Designed To Control The Training Complex, Design (develop) Exercises, Perform Exercises In Real Time, Control Exercise Performance By Trainees, Change Environmental Conditions And Sailing Circumstances, As Well As Enter Own Ship Failure Variables, Document, And Archive The Position And Activity Of The Ship Involved In The Exercise. The Instructor Station Software Should Contain Navigation Areas As Well As Sub-tasks For Each Area, Allowing The Control Of All Active Vessels And Target Ships. 2. Navigation Instructor Software Includes: · Navigation Instructor · Evaluation And Assessment · Tug And Mooring · Radar/arpa · Electronic Navigational Chart: · Bird Eye Of Instructor · Debriefing System 3. Simulator Session(s) Control: • Exercise(s) Start, Pause, Re-start After The Pause, Stop On Bridge(s); • Setting The Initial Position For Own Ships; • Entering Faults Of Navigation Systems, Steering Gear, Propulsion Plant, Fire And General Alarm; • Ability To Set Faults Of Navigational Equipment; • Pulling Apart Ships That Have Collided Or Run Aground; • Control Of Target Vessels, Hoisting Flags Of The International Code Of Signals, Turning Their Sound Signals On And Turning Their Lights On/off; 4. The Software Modules Should Provide A Possibility To Flexibly Configure The Required Bridge Configuration. General: · An Integrated Application For Exercise Editing, Conducting And Debriefing; · Highly Accurate Data Representation Based On Vector Diagrams (ability To Automatically Load All Diagrams Related To The Selected Game Area); · Tools For Creating Exercises And Automatic Competency Assessment Scenarios; · Displaying Of The Actual Ship Contours; · Display Of Object Tracks: Contour Or Point With Selectable Resolution, Track History And Time Stamps; · Using The Mouse Wheel For Chart Scaling; · Control Of Simulator Session(s); · Continuous Automatic Recording Of Data During Exercise (main, Audio And Video Log Files); · Real Time, Slow Time, And Fast Time Modes; · Ability To Display And Print A New Pilot Card And A Table Of Maneuvering Characteristics Of The Ship; · Setting Parameters And Faults Of Navigation Equipment: Radar, Gps, Loran C, Log, Gyro, Echo Sounder, Uais; · Setting Weather And Bathymetric Conditions: Global And Local Zones, Import Of Tide And Current Databases (ecdis); · Working With Measuring Tools: - Ability To Set Erbl; - Ability To Attach, Move Or Delete Erbl During An Exercise; 9. Ability To Attach Sart To The Life Raft; 5. Ability To Move Own Ship During Exercise Without Grounding Or Collision; 6. Ability To Apply Virtual Tug Force To 8 Points Of The Vessel’s Hull In Any Direction; 7. Display Of Actual Ship's Contours; 8. Continuous Display Of Parameters Of Vessel Movement And Environment Conditions: Course And Speed Of The Vessel, Course Over The Ground, Transversal Component Of Speed On The Bow And On The Stern, Gyro Heading, Rate Of Turn, Speed And Direction Of The Current And Wind, Height And Direction Of A Wave, Depth; 9. Independent Instructor Control For Wind And Swell Components Of The Wave; 10. Ability To Set Sea State Spectrum: · Pierson-moskowitz; · Phillips; · Ittc (international Towing Tank Conference); · Jonswap (joint North Sea Wave Project); · User. 11. Ability To Exclude Hydrodynamic Interaction With Mooring Walls In The Required Area; 12. Ability To Create A Template Containing A Set Of Objects (ships), Save And Use This Template In Other Exercises; 13. Ability To Save Environment Settings As A Template And Load A Previously Saved Template In Any Exercise And Area; 14. Mooring Operations: · Ability To Set The Rope Material; · Ability To Set The Initial State Of The Mooring Winch (render, Slack Away, Stop); · Ability To Set Mooring Winch Parameters (speed, Pulling Force, Holding Force); · Ability To Operate The Mooring Winch At The Instructor Workplace. 15. Anchor Operations: · Ability To Set User Ground Type With Required Anchor Holding Force Coefficients; · Display Of Anchor Position On The Instructor's Chart On The Ground. 16. Control Of Navigational Lights And Shapes: · Ability To Control The Navigational Lights; · Ability To Switch On/off Deck Lights On Target Ships. 17. Loading/discharging Of Own Ship During Exercises; 18. Weather Conditions Manager: · Ability To Set Predefined Weather Conditions By Beaufort Number (wind, Wave, Whitecaps And Foam, 3d Clouds, Cloud Layer, Visibility) On The Fly; · Ability To Set Customized Weather Conditions; · Visual Effects: Rain And Snow (low, Medium, High), Lightning, Reflection, Translucency, Sea With White Caps, Foam, Splashes, Bow-wave; · Separate Settings For Wind Wave And Swell; · Manual Control Of Wind Direction And Strength; · Adjustment Of Atmospheric Parameters – Temperature, Humidity, Pressure; · Ability To Use Thunderstorm, Precipitation; · Automatic Calculation Of The Position Of The Sun, Moon, Major Stars (up To 100) And Constellations, The Angle And Phase Of The Moon; · Ability To Set Wave Spectrum Type: Pierson-moskowitz; Jonswap (joint North Sea Wave Project); Phillips; User-defined; · Ability To Use Thunderstorm, Precipitation. 19. Rcc, Ship And Coast Stating Assignment; 20. Log Module With Possibility To Print Out And Create Archives; 21. Window For Listening/monitoring Of The Radiotelephone Traffic Including Possibilities To Interfere With Radiotelephone Traffic; 22. Ability To Introduce Background Noise From A List And Instrument Faults To The Trainee Stations. 23. Ability To Change Names, Call Signs, Mmsi, Telex Numbers And Inmarsat Mobile Numbers Of All Emulated Ship Stations And Coast Station According To The Needs Of Different Exercises; 24. Electronic Chart With Vessel Position Indication And The Ability To Change Position, Course And Speed; 25. Ability To Display And Instantly Change Trainee Station Positions On The Electronic Map For Search And Rescue (sar) Exercises; 26. Full Monitoring Of Any Trainee Workstation – The Ability To Monitor The Status Of Each Gmdss Unit And Listen To The Radio Traffic Of Each Trainee Station; 27. Connection To An External Printer; 28. Connection To An Active Speaker For Simultaneous Viewing Of Channels; 29. Providing Functions Of A Coast Telex Or Telephone Subscriber, Coast Radio Station And Rcc Operator From The Log Window; 30. Status Window For All Instruments At Any Workstation; 31. Ability To Log Communication And Trainee Actions For Playback And Later Review; 32. Database Of Coastal Stations, Navtex And Msi Stations And Inmarsat Shore-based Stations Plotted On The Chart; 33. Information About The Gmdss Sea Areas On The Chart; 34. Approximate Estimation Of Radio Wave Propagation In The Selected Frequency Range; 35. Evaluation And Assessment Module; 36. Navtex Functionality: · Ability To Send Navtex Messages On Behalf Of A Navtex Station; · Ability To Edit And Use The Navtex Station Used-defined List; · Ability To Save And Use Navtex Message Templates. 37. “intercom” Panel. To Monitor Intercom Communication, Execute Voice Messages From The Instructor's Side. 38. Vhf Radio Station Module. To Monitor Vhf Communication, Send Voice Messages From The Instructor’s Side, Play Pre-recorded *.wav Files. 39. Coastal Radio Station Module. Screen Layout: 40. Use Of The Mouse Wheel For Chart Centering And Scaling; 41. On-screen Display Of Mooring Walls And Piers; 42. On-screen Display Of Actual Contours Of Any Ship; 43. On-screen Display Of The Object’s Route Line And Its Actual Track; 44. On-screen Display Of The True And Relative Speed Vectors; 45. Selectable Display Mode: True Motion, Relative Motion, Course Up Or North Up; 46. Display Of Prompt And Other Information In The Status Bar: · Bearing And Distance From The Current Cursor On-chart Position To The Reference Point; · Coordinates Of The Current Cursor On-chart Position; · Depth In The Current Cursor Position; · Current Exercise Time (absolute And Relative). 47. Displaying Of Object Tracks: Contour Or Point With Selectable Resolution, Track History And Time Stamp; 48. Displaying Of Walls And Piers; 49. Use Of A Mouse Wheel For Chart Centering And Scaling; 50. User Configurable Workplace; 51. Different Panels For The Control And Monitoring Of The Exercise Fulfillment: · Reports Panel – To Form And Print Exercise Fulfillment Reports; · Ship Info Panel – To Display Courses, Longitudinal And Transverse Speeds, Rates Of Turn For All The Ships Involved In The Exercise. · Evaluation And Assessment Module Panel; · Target Panel – To Control Vessel Target And Flight And Sar Objects; · Objects Panel – To Promptly Select An Object On The Chart From The List Of All The Objects Available In The Exercise; · Flags Panel – To Hoist/lower Ics Flag Signals On Any Of The Ships, Including Ability To Set And Keep Flag Templates · Events Panel – For The Automatic Recording Of Any Important Events Related To The Incorrect Trainee Actions; · Flash Light Panel – To Send Light Signals From Target Vessels, Including Automated Translation Into Morse Code; · Magnetic Deviation Panel – To Configure The Magnetic Deviation Panel For The Vessels, Participating In The Exercise, Save The Panel And Apply Desired Template To Any Own Vessel, Print The Magnetic Deviation Table; · Procedural Alarms Panel – For Defining User Set Of Alarm For Dedicated Vessels. 52. Setting Navigational Equipment Parameters And Faults: Radar, Gps, Loran C, Log, Gyro, Echo Sounder, Uais; 53. Setting The Exercise Weather And Bathymetric Conditions: Global And Local Zones, Import Of Tide And Current Databases; 54. Observing Own Ships And Targets On The Chart: Ship Info Panel, Cpatcpa Panel, Events Panel; 55. Control Of Own Ships And Targets On The Chart: Direct Control Of Steering And Propulsion Systems, Autopilot, Mooring Lines, Anchors; 56. Setting Faults Of Navigational Equipment, Steering And Propulsion System, Fire And General Alarms; 57. Continuous Data Logging During Exercises; 58. Playback Of Recorded Exercises In Real And Fast-time Modes; 59. Performing Preliminary Exercises On The Map To Check Their Suitability For Training On The Simulator; 60. Distress Signals (flare, Smoke Signals, Dye Markers); 61. Adding New Target Ships; 62. Changing Weather Conditions; 63. Moving Buoys, Turning Off Lights On Them And Hiding Them On Both The Visualization System And Radar; 64. Control Of Automatic Tugboats On Commands From The Bridge Or From The Instructor; 65. Generating And Printing Exercise Reports 5.4 Simulator Scenario Development Station 1. The Simulator Scenario Development Station Shall Be Integrated With All Engine Stations And Instructor Stations, And Can Act As An Instructor Station Capable Of Deploying Scenarios To Other Stations (bridge And Engine) 2. The Simulator Scenario Development Station Shall Have The Same Software And Control Capabilities As The Instructor Station. (see Section A 5.5.3) B. Full Mission Engine Room Simulator (fmers) And Mini Er Stations’ Features And Applications, Major Components And Engine Room Simulator Performance Standards 1. Major Components The Full Mission Engine Simulators That Can Be Integrated With Bridge Simulators Shall Consist Of The Following Major Components: A. One (1) Full Mission Engine Room Station (class A Configuration) B. Ten (10) Mini Engine Room Stations (class B Configuration) C. One (1) Server Station D. One (1) Instructor Station E. One (1) Simulator Scenario Development Station F. One (1) Briefing/ Debriefing Station 2. Features And Applications 2.1 The Man Electronic Engine Model Simulates A Suez Max Crude Oil Carrier With A Man Slow Speed Turbo Charged Diesel Engine As Propulsion Unit Modeled With Fixed Propeller. The Main Engine Models Respond Dynamically To Variations In Operation And Conditions Of The Ship Model, And The Ship Models Have Mutual Responses To The Main Engine Models. The Model Is Based On Real Engine Data That Makes The Dynamic Behavior Of The Simulator Close To Real Engine Response. In Addition To The Man Engine, The Vessel Has An Electrical Power Plant Including Three 1125 Kva Diesel Generators And One 250 Kva Emergency Generator. The Steam Plant Includes Two D-type Steam Boilers, Based On Alfa Laval And One Composite Boiler (aalborg), 3 Cargo Turbines, Condensing And Feed Water Systems. Control Room Operator Station, Bridge And Steering Panels Are Included. The System Shall Also Be Connected To The High Voltage Engine Simulator. 2.2 The Simulator Models Complies With The Requirements In The Stcw Convention, Regulation 1/12 And Fulfill The Standards Of An Internationally Recognized Classification Society For Maritime Simulator Systems. 2.3 The Engine Model Main Specifications High Fidelity Engine Room Systems Include: - Sea & Lt/ht Fresh Water Systems, Incl. Fw Generator - Electrical Power Plant, Incl. Diesel Generators And Power Management - Start & Service Air Compressors, Incl. Compressor Intermediate Coolers And Emergency Compressor - Integrated Automation System, Incl. Vessel Performance Monitor - Steam Plant Incl. D-type Oil Fired Boilers And Combined Exhaust/oil Fired Boiler - Diesel/heavy Fuel/oil Systems, Incl. Hfo, Lshfo And Mdo Tanks, Separators, Viscometers - Lubricating Oil Systems, Incl. Separator - Stern Tube Systems - Steering Gear - Main Engine Control System (man) - Main Engine Remote Control System (ac 600) - Main Engine Maneuvering System - Main Engine Hydraulic Oil System - Main Engine Hydraulic Cylinder Units System - Cylinder Indication Diagrams - Air Ventilation System - Bilge Wells & Bilge Separator - Sewage Treatment Plant - Incinerator Plant - Inert Gas System - Ballast System - Refrigeration System - Ship Loading System - Fire Detection System - Fire Fighting System - Remote Co2 Release, Emergency Stops And Quick Release Valves - Emission Control System (water Scrubbing And Me Low Nox Mode) 2.4 The Engine Simulator Product Shall Be Able To Address The Following Stcw Competencies And Shall Be Reflected In The Certificate: · Table A-iii/1.1 – Maintain Safe Engineering Watch · Table A-iii/1.3 – Used Of Internal Communication Systems · Table A-iii/1.4 – Operate Main And Auxiliary Machinery And Associated Controls · Table A-iii/1.5 – Operate Fuel, Lubrication, Ballast And Other Pumping Systems And Associated Control Systems · Table A-iii/1.6 – Operate Electrical, Electronic And Control Systems · Table A-iii/1.7 – Maintenance And Repair Of Electrical And Electronic Equipment · Table A-iii/1.11 – Maintain Seaworthiness Of The Ship 2.5 Interface To Engine Room High Voltage System - The Engine Room Model Will Be Interfaced To A Corresponding High Voltage Simulator And Gas Turbine Installed In The Academy. 3. Engine Room Simulator Performance Standards 3.1 Physical Realism The Engine Simulator Stations Shall Have The Following Physical Realism: A. Equipment And Consoles Shall Be Installed, Mounted, And Arranged In A Ship-like Manner B. The Control Room Consoles Shall Include Control And Monitoring Of The Main Engine, Auxiliary Engines And Electrical Power Generation, Steam Boiler, Pump, Compressors And All Other Alarms. C. The Remote Monitoring And Control Systems Shall Be In Compliance With The Functional Requirements Of The Classification Societies For Periodically Unattended Machinery Spaces. D. The Main Engine Remote Control Console Shall Include Command Functions And Status Indication Normally Found On Board Ships. E. The Electric Power Generation Shall Be Under Automatic Or Manual Control. Such System Should Be Able To Constantly Monitor Demand And Supply. When Deviation From Pre-set Limits Arises, The System Should Be Able To Act In Order To Normalize The Situation. The System Shall Also Perform Continuous Control Of The Frequency And Load Sharing. F. The Electric Power Supply System Shall Be Operated Either From The Switchboard Or The Power Management System. - Remote Start/stop Of Auxiliary Diesel Generators - Operation For Shaft Generator - Connect/ Disconnect Of All Generators - Automatic And Priority Selection - Non-essential Systems Trip - Constant Frequency Mode - Different Control Modes Of Load Sharing G. The Main Switchboard Shall Be A Full Scale Model Of A Typical Switchboard, And Comprise The Necessary Controls And Indicators Usually Available Of Real Generators. H. The Remote Control And Automation System Must Include Control Of The Following Equipment: - Me Lubricating Oil Pumps - Me Fresh Water Cooling Pumps - Me Sea Water Cooling Pumps - Me Auxiliary Blowers - Fuel Oil System And Pumps - Air Compressors - Steering Gear Pumps - Fire Pump Each Of The Above Individual Units Shall Allow Manual Start And Stop From The Control Room Consoles. It Shall Also Be Possible To Use Automatic Start And Stop Where Applicable. I. The Alarm Monitoring System Shall Consist Of A Typical Shipboard Alarm System. J. An Alarm Shall Be Announced By Sound And By Flashing Light In The Control Room. K. A Printer Or A Computer In The Engine Room Control Shall Be Used As An Alarm Log And Event Log. L. “dead Man Alarm System” The Simulator Shall Have The Following Additional Requirements For Low Speed Engine: M. The Simulated Engine Room Shall As A Minimum Reflect Typical Machinery Found On Merchant Ships. The Following Main Components Shall Be Simulated And All Necessary Sub-systems Included For A Low Speed Engine: - Main Engine Including Turbocharger System - 2 Auxiliary Diesel Generators - Lubrication Oil Separator - Steering Gear System - Fire Pump - Shaft Generator - Cooling Water System Including Freshwater Generation System - Turbo Generator - Fuel Oil Bunkering System - Fuel Oil Settling And Service Systems - 2 Heavy Fuel Oil Separators - 1 Diesel Oil Separator - Steam Generation Plant Including Exhaust And Oil-fired Boilers - Diesel Oil And Heavy Fuel Oil Supply To Main And Auxiliary Engines - Main Engine Operation From Engine Room, Engine Control Room And Bridge - Turbocharger System - Air Ventilation System For Engine And Control Room - Bilge Water System Including Oily Water Treatment Systems - Stern Tube System - Deck Machinery Applicable To The Ship Model - Ballast System - Sewage Treatment System The Simulator Shall Have The Following Additional Requirements For Medium And High Speed Engine: N. The Simulated Engine Room Shall Consist Of Typical Machinery Found On Merchant Ships. The Following Main Components Shall Be Simulated And All Necessary Sub-systems Included For A Medium And High Speed Engine: - One Or More Main Engines - Main Sw System - 2 Auxiliary Engines - Fuel Oil Tanks - Fuel Oil Separator - Lubrication Oil Separator - Main Engine(s), Including: • Fresh Water System • Lubrication System • Turbocharger System • Me Sw System - Reduction Gear System - Controllable Propeller Pitch Were Applicable - Steam Generation System As Applicable - Freshwater Generator - Bilge Wells And Bilge Separation System - 2 Air Compressors - Steering Gear System - Fire Pump - Electrical Power Plant - Deck Machinery Applicable To The Ship Model - Ballast System - Sewage Treatment System The Simulator Shall At Least Have The Following Additional Requirements For Machinery Spaces: O. The Simulated Machinery Spaces Shall At Least Include One Dedicated Room For This Purpose. P. At Least The Following Main Components Of The Machinery Spaces Shall Be Graphically Presented Or Represented By Mock-ups Or In Realistic Visualization (to Illustrate Physical Presence) In The Simulated Machinery Spaces: - Main Engine - Auxiliary Diesel Generators - Steam Boiler - Fire Pump Q. The Facilities For Local Operation In The Simulated Machinery Spaces Shall Consist Of Local Operating Stations For Each System. Each Station Shall Be Furnished With Start/stop (open/closed) Buttons And Status Lights, Various Numbers Of Pressure -, Temperature Indicators, Etc. The Local Operating Stations Shall At Least Give Means To Operate The Following: - Main Engine (me) - Me Lubricating Oil Systems Including Separator - Me Fresh Water Cooling System - Me Sea Water Cooling System - Me Auxiliary Blowers - 2 Auxiliary Diesel Generators - Steam Boiler - Fuel Oil System (diesel And Heavy Fuel Oil) Including Separator - 2 Air Compressors - Steering Gear System - Bilge Water System - Fire Pump R. All Valves Typically Associated With The Operation Of Above Machinery May Be Operated At The Computer Screen In A 3d Visual Form Or Mouse Operated By The Candidate. S. Internal Communication System. 3.2 Behavioral Realism The Engine Simulator Stations Shall Have The Following Behavioral Realism: A. The Simulator Models Shall Be Able To Replicate The Dynamic Behaviour Of The Machinery Systems And All Its Visual Parameters As Well As The Interactions Between The Sub-systems. B. The Simulator Models Shall Simulate The Engine Room Components With Their Procedures, As Well As Modelled Controller Systems (sensors, Controllers, Actuators, And Valves) Connected To The Processes. C. When Simulating Real Equipment The Behaviour Of Such Simulated Equipment Should Behave As Identical Aw Possible As The Original. Critical Parameters Of The Behaviour Shall Be Documented D. The Simulator Model Shall Make Applicable Controllers Available And Adjustable With Regards To Pid (proportional-integral-derivative Controller) Parameters. E. The Simulator Model Shall Provide Facilities To Allow The Injection And Resetting Of Malfunctions At Appropriate Times During Operation As Necessary. F. It Shall Be Possible To Simulate Change In Seawater Temperature And Demonstrate How This Affects The Complete Simulation Model. G. It Shall Be Possible To Simulate A Change In Air Temperature And Demonstrate How This Affects The Complete Simulation Model. H. The Simulator Shall Have All Heat Exchangers Available And Adjustable With Regards To Their Parameters (heat-transfer Factor, Heat Dissipation Are Etc.) I. The Simulator Shall Make All Pumps Available And Adjustable With Regards To Their Parameters (pump Capacity, Wear, Etc.) J. It Shall Be Possible To Demonstrate Systematically The Tests That Are Made On The Ums (unmanned Machinery Space) Alarm System. K. It Shall Be Possible To Simulate Auto Slow-down And Emergency Shut Down L. It Shall Be Possible To Simulate Safe Methods To Test Inert Gas Generator (ig) Alarms And Control. M. It Shall Be Possible To Simulate Testing Of The 24v D.c. Power Supply To The Navigation, Communication And Engine Room Control Console In Event Of Power Failure. N. It Shall Be Possible To Simulate Safe Method Of Testing The Insulation For Rotor And Stator. O. It Shall Be Possible To Simulate Of Reading A Power Factor Meter With Reference To Four Segments P. It Shall Be Possible To Simulate Testing Of The Devices And Relays Provided For Generator Protection Q. It Shall Be Possible To Simulate Tests Related To Avr (automatic Voltage Regulator) R. It Shall Be Possible To Simulate Methods Of Cooling And Checking Of Air Gap S. It Shall Be Possible To Simulate The Precautionary Measures When Megger Testing The Rotor Of A Brushless Generator T. It Shall Be Possible To Simulate Routine Tests On An Emergency Generator U. It Shall Be Possible To Simulate How A Generator Circuit Breaker Ocr (over Current Relay) Is Set And Tested. V. It Shall Be Possible To Simulate The Process Of Connecting A Shaft Generator On Load And Specific Conditions For Taking Off Load. W. It Shall Be Possible To Simulate The Procedure For Megger Testing A High Voltage System X. It Shall Be Possible To Simulate The Maintenance And Checks Carried Out On An Acb (air Circuit Breaker) Y. It Shall Be Possible To Simulate Recovery From “dead Ship” Condition. Z. It Shall Be Possible To Simulate Methods Test The “preferential Tripping Sequence” Aa. It Shall Be Possible To Simulate Methods To Tests Auto “cut In” Of Stand Fault Bb. It Shall Be Possible To Simulate Methods Of Diagnosing Single Phasing Fault. Cc. It Shall Be Possible To Simulate Operation And Maintenance Of Variable Speed Motor Starters. Dd. It Shall Be Possible To Simulate Operational Test Methods Of Oily Water Separator Monitors Ee. It Shall Be Possible To Simulate Test Methods For Level Alarms And Function Tests Of Bilge Pumping Arrangement Ff. It Shall Be Possible To Simulate The Functional Tests Of Odmcs (oil Discharge Monitoring And Control System) And Odme (oil Discharge Monitoring Equipment) System Gg. It Shall Be Possible To Simulate The Function Test Of Ows (oily Water Separator) And Ppm (parts Per Million) Unit. 3.3 Operating Environment The Engine Simulator Stations Shall Have The Following Operating Environment: A. It Shall Be To Adjust The Noise Level In The Simulated Machinery Spaces Infinite From No Added Noise Up To Minimum 100 Db(a). The Noise Shall Have A Frequency Distribution Typical For Machinery Spaces. Headset Is Provided For Each Workstation. B. It Shall Be Possible To Simulate The Sea Water Temperature At Least Infinite Between +1ºc And +30 ºc C. An Alarm Can Be Heard Through Headset Of A Candidate And By Flashing Light In The Machinery Spaces 4. Hardware Requirements 1 Set 4.1 Full Mission Engine Room Simulator A. Engine Control Room Consoles I. Ecr Pump Compressor And Power Management Console 1. 1 X Console 2. 1 X Computer 3. 2 X 24 Touch Monitors Ii. Ecr2 Alarm, Monitoring And Remote-control Console: 1. 1 X Console 2. 1 X Computer 3. 1 X Keyboard 4. 1 X 24” Touch Monitor 5. 1 X Industrial Tracker Ball Iii. Ecr3 Main Engine Remote Control And Indication Console 1. 2 X Console 2. 1 X Computer 3. 3 X 24” Touch Monitors 4. 1 X Speed Set Lever For Main Engine Remote Control And 5. Indication Console 6. Dead Man Alarm (dma) 7. Engineers Reset 8. Included Power Relay To Which Illumination In Engine Control Room And Engine Room Can Be Connected, Causing Lights In The Rooms To Go Out During A Blackout To Increase Realism. Iv. Simulated Cctv Touch Monitor 1. 1 X Computer 2. 1 X 24 Monitor V. Internal Telephone At The Following Locations 1. Instructors Station 2. Engine Control Room 3. Engine Room 4. Emergency Generator Room Vi. Main Switchboard 1. 14 X Touch Screen Monitors 2. 7 X Computers 3. 1 Set Of Speakers 4. Installed In A Switchboard Manner Vii. Engine Room Equipment 1. 4 Dome Type Virtual Walkthrough 2. 4 X High Resolution Short Throw Projector 3. 4 X Computer With Graphics Card 4. 4 X Controller Viii. Local Operating Station Console 1. 1 X Console 2. 1 X Computer 3. 1 X Keyboard 4. 1 X 24” Touch Monitor 5. 1 X Industrial Tracker Ball Ix. Engine Room Sound 1. 1 X Sub Woofer 2. 4 X Satellite Speaker X. Alarm Horn And Lamp 1. 1 X Column With Lights And Sirens Xi. Emergency Generator Room 1. 1 X Dome Type Virtual Walkthrough 2. 1 X High Resolution Short Throw Projector 3. 1 X Computer With Graphics Card 4. 1 X Controller 5. With Sound System B. All Computers Must Be The Latest Generation This Includes Processors, Memory, Graphics Card And Storage. I. Monitors: Full Hd Resolution Ii. Storage: Solid-state Drive (ssd) Iii. Processor Generation: Must Be From The Latest Generation Of Processors Iv. Graphics: Integrated Graphics Dedicated Gpu If Needed. C. Touchscreens For Durability, Responsiveness, And Multi-touch Support. D. Each Computer Must Be Paired With A Ups Unit Rated For At Least 1.5 Kva And Automatic Voltage Regulation To Handle Voltage Fluctuations. E. The Engine Control Console Must Be Made From Steel W/ Handrails 10 Sets 4.2 Mini Engine Room Simulator A. 1x Computer Specification (minimum Requirement) 1. Intel Core I5 Processor 2. 16 Gb Ram 3. 256 M.2. Ssd 4. Video Card 5. Keyboard/mouse 6. 2x At Least 24" Monitor (touchscreen) 7. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator B. 1x Table Size: At Least L 1200 X W 800 X H 750 Mm C. 1x Chairs 1 Set 4.3 Engine Instructor Station A. Instructor Station I. 1x Computer (minimum Requirements) 1. 3x 24” Monitor 2. Intel Core I5 Processor 3. 16 Gb Ram 4. 256 M.2 Ssd 5. Keyboard/mouse 6. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator Ii. 1x Speaker 1. Type: Desktop 2. Port: Mini Jack Iii. 1x Steel Cabinet W/ Lock 1. Metal Drawer Office Drawer 2. File Cabinet Storage With Wheel Iv. 1x Smart Tv 55” Tv Led For Cctv V. 1x Printer 1. Laser Printer A4 2. A4 Print Speed Up To 48 Ppm 3. Auto 2-sided (duplex) Printing, 1-line Lcd 4. Wifi, Airprint, Mopria, Wifi Direct, Lan, Usb 2.0 5. Colored Printer Vi. Instructor Station Table Specification: Vii. 11x Two-way Vhf Radiotelephone (walkie-talkie) With Charging Connection Viii. 1x Table Size: At Least L 1700 X W 700 X H 750 Mm 1. Material: Formica Matt Laminate On Chipboard Ix. 1x Ergodynamic Chair X. 1x Document Metal Cabinet With Glass Sliding Door 1. Size: 1850x 400mmx 900mm 2. Door Lock 1 Set 4.4 Engine Simulator Scenario Development Station A. Scenario Development Station As An Instructor Station Capable Of Deploying Scenarios To Other Stations (bridge And Engine) 1. 1x Computer (minimum Requirements) 2. 2x 24” Monitor 3. Intel Core I5 Processor 4. 16 Gb Ram 5. 256 M.2 Ssd 6. Rtx 4070 Or Higher 7. Keyboard/mouse 8. Ups 1.5kva A. Surge Protection B. W/ Automatic Voltage Regulator B. 1x Table Size: At Least L 1200 X W 800 X H 750 Mm I. Material: Formica Matt Laminate On Chipboard Ii. 1x Ergodynamic Chair 5. Software Requirements 5.1 Full Mission Engine Room Simulator 5.2 Mini Engine Room Simulator 5.3 Instructor Station 5.4 Simulator Scenario Development Station 1. The Simulator Scenario Development Station Shall Be Integrated With All Engine Stations And Instructor Stations, And Can Act As An Instructor Station Capable Of Deploying Scenarios To Other Stations (bridge And Engine) 2. The Simulator Scenario Development Station Shall Have The Same Software And Control Capabilities As The Instructor Station. (see Section B 5.5.3) 1 Set C. Briefing/ Debriefing Station For Bridge And Engine A. 2x Computer (minimum Requirements) 1. 1 X Pc 2. Intel Core I5 Processor 3. 16 Gb Ram 4. 500gb Ssd 5. Low Profile Video Card 6. 1x Keyboard/mouse 7. 1x Ups 1kva 8. 1x W/ Computer Table Size: At Least L 1700 X W 700 X H 750 Mm 9. Briefing And Debriefing Rooms With Playback Capability (playing Of Recorded Exercise And Assessment In Simulator B. 50x Chairs C. 1x Solid Round Table (at Least 6100 X 1220 Mm) (for Bridge Briefing/debriefing) I. (metal Legs With Laminate Board Or Solid Wood Table) D. 1x Solid Round Table (at Least 4880 X 1220 Mm) (for Engine Briefing/debriefing) I. (metal Legs With Laminate Board Or Solid Wood Table) E. 1x Smart Tv At Least 70" 4k 1. Wall Mounted. 2. 2x Hdmi 10meters F. 4x Bridge And 4x Engine) Hardware For Virtual Bridge Familiarization (minimum Requirements) 1. Display: A. Type: Lcd B. Resolution: 2064 X 2208 Per Eye C. Refresh Rate: 120 Hz D. Field Of View: E. Horizontal: 97 Degrees F. Vertical: 93 Degrees 2. Processor: A. Chipset: Qualcomm Snapdragon Xr2 Gen 2 3. Ram: 12gb 4. Storage: A. Options: 128gb, 256gb, And 512gb Variants 5. Audio: 6. Hand Tracking: Improved Hand Tracking Capability 7. Controllers: A. Type: Meta Touch Pro Controllers B. Features: Haptic Feedback, Improved Ergonomics, Rechargeable Batteries 8. Battery: A. Headset: Approximately 2-3 Hours Of Active Use B. Charging: Usb-c Fast Charging 9. Connectivity: A. Wireless: Wi-fi 6e Support B. Bluetooth: 5.2 10. Inclusions: A. Headset B. Touch Pro Controllers (pair) C. Charging Cable (usb-c) D. Power Adapter W/ Extra 1 Battery Each E. Controller Lanyards F. Glasses Spacer Ii. Add On’s: 1. 2x Strap With Battery 2. 8x Silicone Cover Face Cover 3. 4x Silicone Protective Case 4. 8x Silicone Case For Controller 5. 3 Row Vr Storage Cabinet With Lock G. The Virtual Reality Bridge Must Be Complete With Hotspots, Identification Tags And Descriptions. It Shall Also Be Available On An Offline System, Navigable. H. Playback Capability With The Following Functions: · Loading A Previously Created Exercise On A Chart Or In Engine Room; · Playing The Exercise To Explain The Task; · Uploading A Sample Log Of The Same Exercise To Explain The Correct Actions. I. Virtual Bridge Familiarization W/ Virtual Reality Device The Vr System Aims To Simulate The Overhauling Process, Enabling Immersive, Hands-on Learning And Pre-assessment Without Direct Physical Intervention On The Engine. This Approach Will Enhance Technical Skills, Reduce Risk, And Improve Efficiency In Real-world Engine Maintenance And Overhauling. The Supplier Shall Provide A Virtual Bridge And Engine With The Use Of Virtual Reality Providing The Following Visualizations: 1. Bridge Wing Equipment 2. Speaker Mic 3. Rate Of Turn 4. Engine Rpm 5. Quick Release Lifebouy 6. Remote Panel 7. Gyro Compass Repeater 8. Fire Box 9. Hatch For Maintenance 10. Thermometer Ii. Main Bridge 1. Epirb 2. Sart 3. Clear View Screen 4. Location Of Fire Extinguishers 5. Pantry With Equipment 6. Pilot Chair 7. Smoke Detectors 8. Damage Control Plans 9. Radar 1 And 2 And 3 10. Gps With Other Equipment 11. Helm Wheel 12. Indicator Control 13. Deck Light Control 14. Admiralty And Other Maritime Publications 15. Fireplan 16. Rudder Angle Indicator 17. Voice Recorder 18. Whistle Horn 19. Water Tight Door Indicators 20. Window Wipers 21. Pa Systems 22. Cargo Hold Fan Control 23. Smoke Alarm System 24. Fire Alarm System 25. General Alarm System 26. Vhf System 27. Log Books And Other Documentation 28. Ecdis Voyage Planner 29. Pressure Recorder 30. Portable Uhfs 31. Lifejackets, Rocket Flare, And Rocket Line 32. Location Of Immersion Suits 33. Barometer 34. Utc Clock 35. Radio Room Configuration 36. Posters 37. Charts 38. Compass Deck / Monkey Island 39. Radar Equipment 40. Antennas 41. Anemometer 42. And Other Equipment On The Monkey Bridge Iii. The Me-b Main Engine Vr Overhauling System Cover The Following Features Full-scale, Interactive Models Allowing For A Detailed Exploration Of All Engine Components, Including: Iv. Connection Rod & Crosshead Assembly V. Stuffing Box Assembly Vi. Piston Assembly Vii. Cylinder Liner Assembly Viii. Cylinder Cover Assembly Ix. Exhaust Valve Assembly X. The Vr Simulation Guides Users Through Disassembling, Inspecting, And Reassembling The Exhaust Valve, Focusing On Critical Tasks Like Checking Valve Seats, Spindle Condition, And Wear On Sealing Surfaces. Users Can Also Simulate Tasks Such As Lapping The Valve, Inspecting Hydraulic Actuators, And Ensuring Proper Seating Of The Valve During Reassembly. 1 Set D. Server Station For Bridge And Engine A. 2x Set Computer (minimum Requirements) 1. Intel Core I5 Processor 2. 16 Gb Ram 3. 4x 500 Ssd 4. Keyboard/mouse 5. License Operating System B. 1x Nas And Exercise Server 1. 4 Bay Nas Disk Station Quadcore Processor 2. 4x 4 Tb Hdd C. 1x Server Rack 1. Server Rack At Least 32u 2. W/ Fan D. 1x Ups 1. 5kva (5kw) 2. Sealed Lead-acid (sla) Or Lithium-ion 3. Output Voltage: 230v Ac 4. Surge Protection 5. Stabilizes Incoming Voltage Without Switching To Battery Mode 25 Sets E. Cloud Simulator-ready Computers A. Laptop 1. 13th Gen Intel Core I5-1335u 2. 16 Gb, 2 X 8 Gb, Ddr4. 2666 Mhz 3. 512 Gb, M2, Pcie Nvme, Ssd 4. Intel Iris Xe Graphics 5. Windows 11 Pro License 6. Wi-fi 6 Wireless Lan And Bluetooth 7. Keyboard With Numeric Keypad 8. 15.6", Fhd 1920x1080, 120hz, Wva, Non-touch, Anti-glare, 250 Nit, Narrow Border, Led-backlit 9. Ports: Usb 2.0, Headset Jack, Power Jack,hdmi 1.4, Usb 3.2 Gen 1 Type-a, Usb 3.2 Gen 1 Type-c™ 10. Power Adapter: 220v Ac Input, 65w 11. Accessories: Wireless Mouse 1 Set F. Network And Cctv A. 1 X High Speed Router For Remote Support B. Network Switch 1. Network Switch Specifications Manage: 2. 4x 24 Ports 10/100/1000mbps Rj45 Ports 3. 1x 8 Ports 10/100/1000mbps Rj45 Ports C. Set Cctv Monitoring 1. 1x Nvr At Least 32 Channel 2. 20x 6 Mp Fixed Dome Network Camera With Mic 3. 3x 6tb Storage (design For Cctv) D. Network Requirements: I. 72x Lan Port Ii. 1x Lot: Of Upvc, Conduit, Pull Box, Fittings, Hanger, And Support And Other Materials If Needed. Including Utp Cat6 Shielded Pure Copper, Fiber Optic Cable, Patch Panels. Iii. Installation, Engineering Labor For Entire Project. Iv. Cable Laying, Labeling, Harnessing V. Mobilization And Di-mobilization Vi. All Cabling Will Be Endpoint At Server Room (back Of Full Mission Bridge Simulator) E. Structured Cabling Systems Standard I. Stations Must Include Lan Outlets And Patch Cords. Ii. Backbone Cabling Will Be Using The Cable Tray For Lan Distribution. Iii. Lan Outlets Must Have Network Labeling Iv. Patch Panels Are Required G. Civil Works A. Program Of Work Separate Documents (attached) Part Ii. Other General Requirements 1 Ea. Project Billboard/signboard 1 L.s Occupational Safety And Health Program 1 L.s Mobilization/demobilization Part Iii. Civil, Mechanical, Electrical, & Sanitary/plumbing Works Part A. Earthworks 1 L.s Removal Of Structures And Obstruction Part C. Finishings And Other Civil Works 179.71 M² Wall, Metal Frame, Fiber Cement Board 6mm 37.92 M² Tempered Glass Door, 12mm, Reflective 23.04 M² Aluminum Glass Window 4.05 M² Doors, Solid Panel 406.28 M² Acoustical Ceiling Panel 745.2 M² Painting Works, Masonry/concrete 4.05 M² Painting Works, Wood 48.38 M² 150mm Chb Nonload Bearing(including Reinforcing Steel) 48.38 M² Plain Cement Plaster Finish 116 M² Floor Tiles, Imo Rubber, On Finish Floor 211.6 M² Floor Tiles, Imo Rubber, On Raised Floor System Part D. Electrical 1 L.s Panelboard With Main And Branch Breakers 1 L.s Wires And Wiring Devices 1 L.s Lighting Fixtures And Lamps 1 L.s Conduit, Boxes, And Fittings 1 L.s Pole Mounted Power Transformer (oisc) 1 L.s Network Cabling Part E. Mechanical 1 L.s. Door Access And Card Reader System Part F. Simulator Equipment 1 L.s Airconditioning, Package/split Type H. Terms And Conditions 1. A 3-year Warranty For The Computer Hardware And Console Peripherals 2. All Workstations Shall Have Imo Standard Rubber Mat Flooring. 3. The Software Comes With A 3-year Warranty Inclusive Of New Updates. 4. The Project Will Be Implemented Within 150 Cd. Liquidating Damages Will Be Applicable For Any Delays. 5. A Comprehensive Guide Will Be Provided, Offering Detailed Instructions On System Operation And Maintenance Activities, Facilitating Ease Of Use And System Upkeep. 6. Onsite Training Sessions Will Be Conducted By Certified Instructors And Technical Experts, Facilitating Smooth Knowledge Transfer And Ensuring Proficient System Operation. Certificates Will Be Provided Upon Completion Of Training Sessions. 7. Structured Cabling Standards To Establish A Reliable And Efficient Network Infrastructure. 8. The Simulator Manufacturer Should Be An Iso 9001:2015 And Iso 14001:2015 Certified Business. 9. The Simulator Should Be Certified By An Internationally Recognized Classification Society And May Also Be Certified By National Authorities. 10. The Software Must Be Perpetual License. 11. The Supplier Shall Conduct An Annual Face-to-face Maintenance Session To Ensure The System's Optimal Functionality And Performance. 12. The Supplier Must Resolve Any Software Or Hardware Issues Within 2 To 5 Cd Of Their Occurrence To Minimize Downtime And Disruptions. 13. All Hardware Installations Must Adhere To Software Specifications To Guarantee Seamless Integration And Operation. 14. The Computer Hardware Supplied Must Be Sourced From Proven Technology Hardware Companies, Quality And Performance Standards To Ensure Optimal Functionality And Compatibility With The Software. 15. Bidders Are Required To Offer Continuous Retraining Sessions Free Of Charge During The Warranty Period To Ensure Users' Proficiency With The System. 16. Bidders Should Provide Manufacturer Authorization Or Exclusivity Certificate To Ensure The Authenticity And Legality Of The Supplied Products. 17. The Bidder Is Responsible For Performing A Thorough Site Inspection, And A Site Inspection Certificate Issued By The Agency Shall Be Submitted As Part Of The Eligibility Requirements. 18. The Bridge Simulator Shall Be Integrated With The Engine Simulator Ensuring Compatibility And Functionality. 19. All Simulator Stations Can Connect And Enable Them To Interact With Each Other In A Coordinated Scenario. 20. The Simulator Scenario Development Station Shall Be Capable Same As An Instructor Station Capable Of Deploying Scenarios To Other Stations. 21. All Other Simulator Specifications And Capabilities Not Indicated Herein, The Simulator Shall Comply With The Simulator Performance Standards As Required In Maritime Industry Authority (marina) Evaluation Instrument For Full Mission Bridge And Engine Simulator. 22. The Bidders Should Provide A Breakdown Of The Unit Prices Of The Major Components In The Original Of Duly Signed And Accomplished Price Schedule(s) Under Financial Component Envelope Upon Bid Submission. Furthermore, They Should Provide A More Detailed Breakdown As A Condition For Issuance Of Notice To Proceed. ~~~~nothing Follows~~~~
Closing Date9 Dec 2024
Tender AmountPHP 79.9 Million (USD 1.3 Million)
Province Of Cavite Tender
Electrical Goods and Equipments...+1Electrical and Electronics
Philippines
Details: Description 1. 1 Unit Mortuary Freezer/refrigerator Unit Cost: Php 1,300,000.00 Specification: -2 Body Freezer/refrigerator -dimensions (mm): 2480x810x1300 -body Tray Size: 1940x610mm -insulating Layers: 10 Centimeters -refrigerant: R600a -compressor: – Separate Temperature Controller. Has 3 Compressor -thermostat: Microcomputer Control Digital Display -with Free Additional 1 Body Freezer/refrigerator" Physical Description Finished: Stainless Steel Total Weight: 280kg Utility Requirements Voltage: Ac220v Single Phase Total Power: 880w (2 Units) Avr : 3000 Watts, 230v, 60 Hz, Single Phase, Servo Motor Control Type, Toroidal Transformer, With Delay Timer, Circuit Breaker Switch Accessories, Consumables, Spare Parts, Other Component Interior Roller Racks Flush Mounted Door Heavy-duty Chrome Planted Stainless Steel Body Trays, Refrigerator Wooden Case 6 Pieces Strong Quality Universal Wheel Environmental Requirements Cryogenic Temperature: 0°c~-35°c Temperature Reaches: -10 To 5 Degrees Adjustable 18°c Within 24 Hours 2. 1 Unit 24 Placer Centrifuge Unit Cost: Php 350,000.00 Specifications: •metal Housing And Lid •stainless Steel Centrifuging Chamber •practical Lid Locking Device •viewing Post In The Lid •lid Locking And Holding, Imbalance Switch-off, Automatic Rotor Recognition Emergency Lid Lock Release. •foil Keypad, Speed Rpm: Entry In Increments Of 100, Impulse Key For Short Centrifuging , Rcf Key •max Capacity: 4x100ml / 32x15ml •max Rpm: 6,000min •max Rcf: 4,226 •running Time: 1-99min, Continuous Run, Short Cycle Mode (impulse Key) Avr: 2000w Servo-motor Control Type With Time Delay 230v, 60hz, (toroidal Type Transformer) 3. 1 Unit 6 – Placer Centrifuge Unit Cost: Php 280,000.00 Specifications: •small Tabletop •with 90 Swing-out Rotor And Tubes 6x15ml •for Common Blood Collection Tubes •microprocessor Control •time And Speed Individually Adjustable •pure Key For Short Centrifuging •max. Speed : 4,000min , Max Rcf : 2,254 •voltage: 200 – 240 Avr: 1500w Servo-motor Control Type With Time Delay 230v, 60hz, (toroidal Type Transformer) 4. 1 Unit Serologic Centrifuge Unit Cost: Php 350,000.00 Specifications: •tabletop, Maximum Speed: 6,0000rpm •maximum Capacity : 8x15ml •electrical : 200-240v •built-in Versatile, 8-place, Fixed – Angle Rotor And Adjustable Lcd Avr: 1500w Servo-motor Control Type With Time Delay 230v, 60hz, (toroidal Type Transformer) 5. 1 Unit Platelet Agitator Unit Cost: Php 300,000.00 Specifications: •movement: Flat Bed Agitation •4 Trays (24 Bags ) •frequency Of Oscillation: 65 + / -7 Cycles / Minute •andible Alarm / Beeps For Power Failure •led Indicator For Blown Fuse •continuous Operation •power Supply : 230 + / -10 % Vac 50hz 6. 1 Unit Tissue Flotation Bath Unit Cost: Php 120,000.00 Specifications: •type : Water Bath •electrical Requirements : 230-240v – 60hz •electrical Parameters : 230v:50/60hz, Pmax:300w •controller Type : Microprocessor •led Display •microprocessor – Controlled Heating From Ambient To 65o 7. 1 Unit Vortex Mixer Unit Cost: Php 100,000.00 Specifications: •tabletop Vortex Mixer With 200 To 3000 Rpm + 5% Of Speed Range. •electronic Sensing Technology With Intelligent Control Of Speed, Time And Working Modes •different Oscillation Mixing With 3 Sec Of Acceleration And Deceleration Time •lcd Display, And Permanent Magnet Dc Motor With Over-temperature Protection •two Exchangeable Safety Operation •counting And Countdown Timing Function Specification : •circumferential Shaking Mode •orbital Diameter : 4.5mm •speed Range : 200 To 3000rpm + 5% •maximum Load : 1.0 Kg •operation Mode : Inching : Optical Induction / Continuous Working •speed Control : Pwm Stepless Speed Control •lcd Display •timer Range : 1 Sec To 999 Min •timing Function : Counting And Countdown Timing •power Supply : Dc 24v •with Power Adaptor 24v Dc/ 180-240v 60hz 8. 1 Unit Hot Plate Unit Cost: Php 60,000.00 Specifications: •maximum Temperature : 220°c, Explosion Proof •temperature Range : 40°c – 220°c •plate Diameter : 6.1 •provides 36.5sg. Inches Of Heating Surface •material: Aluminum •electrical : 220v, 5a, 600w, 1ph, 50/60hz Avr: 1500w Servo-motor Control Type With Time Delay 230v, 60hz, (toroidal Type Transformer) 9. 1 Unit Cytocentrifuge Unit Cost: Php 350,000.00 Specifications: •processes 12 Specimens At One Time •dimension (w X D Xh ) •with Closed Lid : 16x9.5x24.5in. (40.5x24x62cm) •with Open Lid : 16x25x24.5in (40.5x62.5x62cm) •weight : 26.5 Lb. (12kg) •power Requirements : 100-240 Vac, 50/60hz, 1ph, 150va Max. 10. 1 Unit Therapeutic Ultrasound Machine Dual Head Small And Large Unit Cost: Php 298,120.00 Features: * Built-in Rechargeable Battery * Multi-frequency Treatment Head 1 And 3 Mhz Large * Continuous And Pulsed Ultrasound Therapy * Contact Control: Automatic Power Switch-off And Treatment Time Interruption In Case Of Insufficient Contact; The Visual Indicator Of The Treatment Head Switched On * Pre-programmed Treatment Suggestions: 25 - Evidence Based * Programmable Positions: 300 * Mains Supply Technical Specifications: Power Supply: 100-240 V ± 10% / 50/60 Hz Dimensions (wxdxh) Device: 24 X 32 X 12 Cm Device With Base: 24 X 30.5 X 18.2 Cm Weight: 2 Kg Weight, Including The Optional Battery: 3 Kg" Standard Accessories: * 4-series Operating Instructions (cd Rom) * 4-series Information Booklet * Mains Cable 230v-eur * Mains Cable 230v-eur * Ultrasound Multi-frequency Treatment Head(s) (model Dependent) * Holder Treatment Head (model Dependent) * Contact-gel, Bottle 250 Ml, 1x" Includes: 1 Pc Multi-frequency Treatment Head, Large (5cm2) 1 Pc Multi-frequency Treatment Head, Small (0.8cm2) 2 Pcs Probe Holder Protector 1 Pc Cart Heavy Duty (local) 1 Pc Sonomed Ultrasound Gel (5 Liters) 11. 1 Unit Continous Passive Motion (cpm) Smart Rehabilitation Solution Unit Cost: Php 650,000.00 Features: * Portable Knee Cpm With Smal Size And Light Weight * Adjustable A Length Of Femur And Tibia Position * Progressive Mode: Relieves Pain By Gradual Increment Of Angle Of Rehalibitating Exercise. * Oscillation Mode: Maximizes Its Therapeutic Effect By Repeating Exercise At Each End-angle. * Allows To Select Speed: Uniform/ Accelerated Mode * Easy Operation With Touch Panel And Customized. " Functions: * Speed 1 - 5 Level * Timer 1 - 99 Min. * Count 1 - 99 * Pause 0 - 9 Sec Technical Specifications: * Femoral Size 26 - 45 Cm * Tibia Size 29 - 59 Cm * Motion Range - 10°~ 140° * Speed 75°~ 130°/min * Angle Of Progressive -5°~ 15° * Angle Of Oscillation -5°~ 15° * Count (progressive) 3 - 10 * Count (oscillation) 3 - 10 * Weight 12kg * Dimentions (wxdxh) 360 X 1025 X 500 (mm) * Power Supply 100vac - 240vac, 50/60hz 12. 4 Units Heavy Duty Suction Machine Unit Cost: Php 285,000.00 Features: •piston/cylinder System – Results In Low Working Speed, Quiet, Low Strain On Movable Parts, Minimum Maintenance •rapid Vacuum Build-up •quiet Drive System •precise Vacuum Setting •protection Against Electric Shock Class I Specifications: High Vacuum: -95kpa, -713mmhg High Flow: 40,50,60 L/min Power: 100-240vac, 150w, 60hz Weight – Trolley: 35.3 Lbs Protection Class Ii: With A Protective Earth. Potential Equalization Conductor: Maintains The Difference In Potential At 0, Thus Preventing Any Transfer Of Static Electricity Running Through The Patient Ip21: Protection From Dripping Water Vacuum Gauge: Kpa & Mmhg 13. 10 Units Portable Suction Machine Unit Cost: Php 85,000.00 Specifications: •max. Vacuum: -75 Kpa / -563 Mmhg ± 10% Tolerance •flow: 18 L/min. ± 10% Tolerance •dimensions: 15″ X 6 3/4″ X 11 1/4″ •weight: 8 Lbs •drive Unit: Quatroflex Piston/cylinder Technology •electrical Info •ac/dc: 100 – 240 V | 50 – 60 Hz •power Consumption •ac: 90 W •ac/dc: 80 W •noise Level: 51.2 Db @ 3 Ft •vacuum Regulator: Membrane •protection Against Electric Shock: Type Cf (cardiac Floating: Max. Earth Leaking Current 10 Μa) •medical Device Classification:class Iia •ingress Protection: Ip21 •battery: Nimh •operating Time On Battery: 30 Minutes •charging Time Of Battery: 5 Hours •low Battery Indication: Led And Acoustic •overflow Protection: Disposable Overflow Protection/bacterial Filter 14. 1 Set Laparoscopic Instrument Set Unit Cost: Php 200,000.00 •2 Maryland Dissecting Forceps •2 Grasper Long Tip •2 Grasper Short Tip •2 Shears •2 Hook (electrocoagulation) 15. 7 Units Hydraulic Hospital Stretcher Unit Cost: Php 150,000.00 Features: -the Main Frame Of The Stretcher Is Made Of Electrostatic Plastic Sprayed Galvanized Steel Tube. -the Mattress Platform Is Made Of X-ray Revealed Material. -it Is Equipped With Imported Double Rise-and-fall Hydraulic Pump Systems. 150 Mm Diameter. -dust Proof Castors With International Advanced Central Locking System Make The Stretcher Move Steadily, Reliably And Lightly. -the Stretcher Has The Functions Of Hi-low, Trendelenburg And Reverse Trendelenburg Which Are Controlled By The Treadles Lying At The Two Sides O The Stretcher. -functions Are Supported By Imported Large Hydraulic Pump Which Make The Stretcher Never Swayed. -the Headrest Is Supported By Gas Spring While The Knee Rest Is Controlled By Manual Crank Which Is In The End Part Of The Stretcher. -the Bottom Cover Is Made Of Abs Material And Shaped Once For All Which Can Be Easily Cleaned. The Stretcher Mattress Platform Is Of Separate Structure. -equipped With Infusion Pole, Drainage Hook And Collapsible Stainless Steel Side Rails. -it Is The Best Choice For Emergency Room And Icu Ward For Transferring Patient. -us Hydraulic Pump Size: 204.5 × 79 × 60.5~92 Cm Specification: Packing Dimension: 213.5 X 86.5 X 81.5 Cm Outer Dimensions (side Rails Up): L2095*w800mm(±10mm) Mattress Platform: L1910*w640mm(±10mm) Bed Height: H585-910m(±10mm) Backrest Angle: 0-90° Maximum Thigh Rest: ≥30° Tr/atr: ≥12° Height Of Side Rails(above Mattress Platform): 420mm(±10mm) Safe Working Load: 200kgs 16. 1 Unit Automatic External Defibrillator Unit Cost: Php 146,776.36 (aed) Infants & Children Ecg Monitoring Pulse Oximetry Aed(energy: 200-joues Max.) Manual External Synchronous/asynchronous Defibrillation Description Display: Screen Type: High-resolutiondisplay, Tft Colour Display Screen Size: 7inches (17.7cm) Diagonally Sweep Speed: 5/25/50mm/sec Information: Heart Rate,nibp,spo2,temp,delivered Energy Resolution: 800x480 Aed Voice Promptsand Screen Prompts. Energy Programmable Sequence: 200,300,360 Joules; 150,150,200 Joules; 50, 75, 100 Joules; 30, 30, 50 Joules; Discharge Control: Control On Device Front Panel. Specifications Ecg: Patient Connection: 3-lead Ecg Cable, Or 5-lead Ecg Cable, Paddles. Lead Selection: Displayed On Monitor, Paddles, I, Ii, Iii,avr, Avl, Avf, V. Ecg Size: 2.5,5, 10, 20, 30 Mm/mv Display On Monitor. Heart Rate: 20-350bpm. Protection: With Stand 4000vac/50hz Voltage In Isolation And Work Against Electrosurgical Knife And Defibrillation Nibp Working Mode: Manual/automatic Method: Automatic Oscillation Cuff Type: Standard Adult; Optional Pediatric/neonatal Temp. Measurement Range 0~50℃ Resolution 0.1℃" Pulse Oximetry(spo2) Display: Spo2 Value, Waveform, Pulse Range:0~99%for Adult, Pediatric And Neonatal Patients Probe: Standard Adult Finger Clip Optional Pediatric Y-type Clip And Neonatal Wrap Defibrillator Waveform: Biphasic Defibrillator Type: Manual External Synchronous/asynchronous Defibrillation. Charge Time: Less Than 10 Seconds To 360 Joules Energy Display: Monitor Display Indicates Both Selected And Delivered Energy. Charge Prompt Type: Voice And Visual Prompts. Energy Selection: Selectable At 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 Joules Standard Adult/pediatric Paddles: Reusable External Adult Paddles (pediatric Paddles Integrated) Battery Description Standard Type: Li-ion Battery Li1104c 11.1vdc 4000mah X2 Standard Capacity: Up To 10 Hours Ecg Monitoring Or 60 Full-energy Discharges. Low Battery Indicator: Flashing Low Battery Icon On Display And Bat Indicator On The Panel Of Defi-monitor Be On Recharge Rate: 80% In 3 Hours. 100% In 5 Hours. Built-in Recorder Paper: 50mm Thermal. Printing Method: High-resolution, Thermal Print Head. Record Date, Time ,sweep Speed, Waveform Gain, Heart Rate, Energy (joule) And Ecg Waveform Print Mode Hr Exceed Limits Alarm Recording Auto Timed Recording Real-time Recording Defibrillation Discharge Trigger Recording Power Ac-dc Dual-use: Use The Batteries,ac100v~240v,50/60 Hz. Vehicle Voltage(option): Dc 12v" Main Unit Portable Dimensions:l320xw205xh410 Weight: 7.5kg" 17. 1 Unit Newborn Hearing Screening Machine- Dpoae Screening (single Oae Probe) W/ Patient Data Transfer Program Unit Cost: Php 750,000.00 Dpoae: Distortion Product Otoacoustic Emission • Extra Oae Probe • Laptop • Smart Label Printer • 20 Rolls Of Thermal Paper • Leak Check: Analysis Of Feedback Signal (440 Hz Probe Tone) • Probe Check: Limit Of Maximum Sound Pressure (“stimulus”), Comparison Across Speakers (“symmetry”), Leak Check (“probe Fit”) • Calibration: In-the-ear Calibration With Ear-canal Volume Adjustment • Noise Detection: Narrow Band Noise Around 2f2-f1 • Residual Noise Calculation: Weighted Averaging, Summed Weighting Factors, • Artifact Rejection: Weighted Averaging • Response Detection: F-test, F-value At A Single Point (fsp) • Frequency Ratio F2/f1: 1.22. Sample Rate: 48 Khz (stimulus, Response) Minimum Dpoae Level Criterion: L1 – 70 Db • Measurement Interval: 4096 Samples • Stimulus Modes With Frequency-modulated Dpoae License: Fm = 1.4-1.6 Hz, Modulation Depth = 50 Hz@1 Khz, 100 Hz@4 Khz • Multi-channel Dpoae: Simultaneous Measurement Of Dpoaes At Up To Two F2 Frequencies At A Time • Frequencies F2: 1, 1.5, 2, 3, 4, 5, 6, 8 Khz • Stimulus Level L2: 30 To 65 Db Spl; Step Size: 5 Db • L2/l1 Relation: Automatic Scissor Paradigm: L1 = 0.4 L2 + 39 Db Spl) • Snr Stop Criterion: 6, 9, 12 Db • Factory Defaults: Quick Screen And Standard Screen (5,4,3,2,khz, Overall Stop Criterion 3 Out Of 4, As Fast As Possible, Multichannel, Fmdpoae, 55/65 Db, Snr 6 Db), Manual Retest Option " "additional Features: • Simultaneous Measurement On Left/right Ear – (2 Probes Required) • Entertainment Mode For All Oae Modules Available • Optional Database Software - Data Management Easily View, Archive And Export Test Results • Stores Up To 1000 Patients On The Device • With The Pc-sw Database That Can Transfer Test Results Via Usb • Results Can Be Sorted By Birthdate, Name, Id, Examiner, Date, Time • Export Full-color, 8.5” X 11” Reports In Multiple Formats, With Graphic And Tabular Data, Preset Or Free Comments • Easily Attach Test Results To Patient Records With Many Emr Systems • Patient Demographics On Evice • Noah Compatible Technical Specifications: Device Dimensions: 209 X 98 X 52 Mm, Ca. 500 G, Ca. 475 Display: 240 X 320 Pixel; Graphic Lcd 3.5”, Resistive Touch Screen, Real Time-clock, Piezo-electric Sound Generator, Usb, Output Voltage And Nominal Impedance (headphone Socket): 5 Vpp, 32 Ω Power Consumption: Max. 2 W. Memory Capacity: Up To 1000 Patients, Ca. 1000 Tests (dependent On Test Type). Terms Of Reference: Https://cavite.gov.ph/home/tor-medical-equip-c-b/ Invitation To Bid For This Project Is Also Posted At Www.cavite.gov.ph
Closing Date2 Dec 2024
Tender AmountPHP 8.2 Million (USD 140.7 K)
Municipality Of Tiaong, Quezon Tender
Civil And Construction...+1Civil Works Others
Philippines
Details: Description 605 Project Signboard Quantity: 5.76 Sq.m. Materials: 1.0 Ordinary Plywood ( 1/2" X 4' X 8') 2.00 Pc 2.0 Coco Lumber (2" X 3" X 12') 5.00 Pc 3.0 Tarpaulin (4' X 8') 1.00 Unit 4.0 Assorted Cwn 1.00 Kg Labor: 1 Skilled Worker 0.50 Day 2 Laborer 0.50 Day Spl - 1 Occupational Safety & Health Program Quantity: 1.00 Lot Materials: 1.0 Safety Helmet 10.00 Pc 2.0 Hand Gloves 10.00 Pair 3.0 Safety Shoes 10.00 Pair 4.0 Safety Glasses 10.00 Pc 5.0 Welding Mask Hat Type (safety Glasses With Shields) 1.00 Pc 6.0 Welding Apron (leather With Sleeves) 1.00 Pc 7.0 Welding Gloves 1.00 Pair 8.0 Safety Harness 5.00 Pc 9.0 Longsleeve Shirt 10.00 Pc 10.0 Miscellaneous Items 1.00 Lot (medicine, Medicine Cabinet, Water, First-aid Kit) 105 Subgrade Preparation Quantity: 249.38 Sq.m Labor: 1 Foreman 3.00 Day 1 Skilled Worker 3.00 Day 2 Unskilled Worker 3.00 Day Equipment: 1 Road Roller 1.00 Hr 1 Road Grader 1.00 Hr 104 Embankment Quantity: 24.94 Cu.m Materials: 1.0 Selected Borrow Materials 26.00 Cu.m Labor: 1 Foreman Day 1 Skilled Worker 2.00 Day 1 Unskilled Worker 2.00 Day Equipment: 1 Road Roller 0.50 Hr 1 Payloader 0.50 Hr 201 Aggregate Base Course Quantity: 24.10 Cu.m Materials: 1.0 Aggregate Base Course 25.50 Cu.m Labor: 1 Foreman 2.00 Day 1 Skilled Worker 2.00 Day 2 Unskilled Worker 2.00 Day Equipment: 1 Water Truck 1.00 Hr 1 Road Roller 1.00 Hr 1 Road Grader 1.00 Hr 803 Structure Excavation Quantity: 82.36 Cu.m Labor: 1 Foreman 3.00 Day 1 Skilled Worker 3.00 Day 2 Unskilled Worker 3.00 Day Equipment: 1 Backhoe With Dozer 8.00 Hr 1 Tamping Rammer 8.00 Hr 804 Gravel Fill Quantity: 2.28 Cu.m Materials: 1.0 Crushed Aggregates 2.50 Cu.m Labor: 1 Foreman 1.00 Day 1 Skilled Worker 1.00 Day 2 Unskilled Worker 1.00 Day Equipment: 1 Tamping Rammer 2.00 Hr 901 Lean Concrete (2000 Psi) Quantity: 1.92 Cu.m Materials: 1.0 Cement 15.00 Bag 2.0 Sand 1.00 Cu.m 3.0 Gravel 2.00 Cu.m Labor: 1 Foreman 1.00 Day 1 Skilled Worker 1.00 Day 3 Unskilled Worker 1.00 Day Equipment: 1 One Bagger Mixer 1.00 Day 900 Structural Concrete Quantity: 32.07 Cu.m Materials: Column Footing/wall Footing 1.0 Ready Mix Concrete, 3500psi 8.00 Cu.m Column/pedestal 1.0 Ready Mix Concrete, 3500psi 7.50 Cu.m Roof Beam 1.0 Ready Mix Concrete, 3500psi 3.50 Cu.m Slab On Grade 1.0 Ready Mix Concrete, 3000psi 16.00 Cu.m Labor: 1 Foreman 11.00 Day 2 Skilled Worker 11.00 Day 8 Unskilled Worker 11.00 Day Equipment: 1 Backhoe Day 1 Concrete Vibrator 2.00 Day 902 Reinforcing Steel Bars, Grade 60 Quantity: 4,008.38 Kg Materials: Column Footing/wall Footing 1.0 Reinforcing Steel 911.50 Kg 2.0 Gi Tie Wire 14.00 Kg Column/pedestal 1.0 Reinforcing Steel 851.50 Kg 2.0 Gi Tie Wire 13.00 Kg Roof Beam 1.0 Reinforcing Steel 370.50 Kg 2.0 Gi Tie Wire 6.00 Kg Slab On Grade 1.0 Reinforcing Steel 1,875.00 Kg 2.0 Gi Tie Wire 28.50 Kg 3.0 Consumables 1.00 Lot Labor: 1 Foreman 10.00 Day 2 Skilled Worker 10.00 Day 8 Unskilled Worker 10.00 Day Equipment: 1 Bar Cutter 4.00 Day 1 Bar Bender 4.00 Day 903 Formworks (scaffolding Included) Quantity: 145.54 Sq.m Materials: Column Footing/wall Footing 1.0 Form Plywood 13.00 Pc 2.0 Form Lumber 911.50 Bd.ft. 3.0 Asstd. Nails 21.00 Kg Column/pedestal 1.0 Form Plywood 28.00 Pc 2.0 Form Lumber 851.50 Bd.ft. 3.0 Asstd. Nails 19.50 Kg Roof Beam 1.0 Form Plywood 11.00 Pc 2.0 Form Lumber 370.50 Bd.ft. 3.0 Asstd. Nails 8.50 Kg Slab On Grade 1.0 Form Plywood 2.00 Pc 2.0 Form Lumber 1,875.00 Bd.ft. 3.0 Asstd. Nails 42.50 Kg 4.0 Consumables Lot Labor: 1 Foreman 13.00 Day 2 Skilled Worker 13.00 Day 8 Unskilled Worker 13.00 Day Equipment: 15 Scaffolding Set, 1.7m X 1.8m X 1.25m 75.00 Day Spl 2 Masonry Works Quantity: 221.53 Sq.m Materials: 1.0 4" Chb 2,908.00 Pc 2.0 Cement 553.00 Bag 3.0 Sand 30.50 Cu.m 4.0 Reinforcing Steel Bars 511.72 Kg 5.0 Gi Tie Wire 8.50 Kg Labor: 1 Foreman 12.00 Day 2 Skilled Worker 12.00 Day 8 Laborer 12.00 Day Hauling Cost 1.00 Lot Equipment: 1 One Bagger Mixer 5.00 Day Spl 3 Welded Wire Mesh (steel Matting) Quantity: 37.55 Sq.m Materials: 1.0 50mm Welded Wire Mesh 40.00 Sq.m 2.0 25mm Flat Bar 7.00 Pc 3.0 75mmø Gi Pipe Sch. 40 2.00 Pc 4.0 Welding Rod 4.00 Kg 5.0 12mm X 350mm X 350mm Base Plate 4.00 Pc 6.0 M12 Anchor Bolt 16.00 Pc 7.0 Chemical Anchor 1.00 Unit Painting 1.00 Lot Labor: 1 Foreman 3.00 Day 1 Skilled Worker 3.50 Day 2 Laborer 4.00 Day 110 Doors And Windows Quantity: 13.83 Sq.m Materials: 1.0 Steel Matting Double Panel Door 6.75 Sq.m 2.0 Steel Matting Single Panel Door 3.38 Sq.m 3.0 Solid Wooden Door 2.10 Sq.m 4.0 Steel Matting Window 1.44 Sq.m 5.0 Awning Window 0.16 Sq.m 6.0 Miscellaneous Items (hinges, Locksets, Etc.) 1.00 Lot Labor: 1 Foreman 2.00 Day 2 Skilled Worker 2.00 Day 2 Laborer 2.50 Day Spl 4 Roofing Works Quantity: 237.16 Sq.m Materials: 1.0 Pre-painted Long Span Rib-type 0.5 245.00 L.m 2.0 Pre-painted Ridge Roll 25.00 L.m 3.0 End Flashing 20.00 L.m 4.0 Gutter 49.00 L.m 5.0 Fascia Board 28.00 Pc 6.0 Tekscrew 1,744.00 Pc 7.0 Blind Rivet 1.00 Box 8.0 Metal Drill Bit 1.00 Box 7.0 Vulca Seal 1.00 Liter 8.0 3" Pvc Pipe (downspout) 12.00 Pc 9.0 3" Pvc Elbow 36.00 Pc 12.0 Miscellaneous Lot Labor: 1 Foreman 7.00 Day 2 Skilled Worker 7.00 Day 8 Laborer 7.50 Day Spl 5 Steel Works (roof Framing) Quantity: 4,000.17 Kg Materials: 1.0 C-purlins 2x3 22.00 Pc 2.0 Channel Bar 2x4 1,696.31 Kg 3.0 Welding Rod 126.00 Kg 4.0 Turco Rust Converter 5.00 Gal 4.0 Epoxy Primer 6.00 Gal 6.0 Epoxy Paint 12.00 Gal 7.0 Paint Brush 6.00 Pc 7.0 Miscellaneous Lot Labor: 1 Foreman 8.00 Day 2 Skilled Worker 9.00 Day 8 Laborer 10.00 Day 1003 Ceiling Works (storage And Cr) Quantity: 30.00 Sq.m Materials: 1.0 Wall Angle 11.00 Pc 2.0 Carrying Channel 8.00 Pc 3.0 Metal Furring 12.00 Pc 4.0 Rod Suspension Hanger With Adjustment Spring 35.00 Set 5.0 Asstd Nails 1.00 Kg 6.0 Hardiflex 1/4" 11.00 Pc 7.0 Self-drilling Screws 252.00 Pc 8.0 Fiberglass Mesh Tape 2.00 Pc Labor: 1 Foreman 2.00 Day 1 Skilled Worker 2.50 Day 1 Laborer 2.50 Day Spl 6 Comfort Room (pipelines Included) Quantity: 10.00 Sq.m Materials: 1.0 30x30 Ceramic Tiles 117.00 Pc 2.0 Tile Adhesive 25kg 3.00 Bag 3.0 Tile Grout 2kg 2.00 Bag 4.0 Water Closet Package (toilet Bowl With Bidet) 3.00 Set 5.0 Cubicle 3.00 Set 6.0 Ss Lavatory 1.00 Pc 7.0 Cement (countertop) 1.00 Bag 8.0 Sand 0.50 Cu.m 9.0 Rebars 7.50 Kg 10.0 Pipelines (water Supply And Waste Water) 1.00 Lot 11.0 Miscellaneous Lot Labor: 1 Foreman 7.00 Day 2 Skilled Worker 8.00 Day 3 Laborer 8.00 Day Spl 7 Booth Partitions Quantity: 59.50 Sq.m Materials: Welding Booths: 1.0 Plain Sheet 42.00 Pc 2.0 Angle Bar 624.24 Kg 3.0 Welding Rod 20.00 Kg Grinding Booths: 1.0 Hardiflex 12.00 Pc 2.0 2x2x12 Lumber 74.50 Bd.ft 3.0 Asstd. Nails/screws 2.00 Kg Bench Work Area: 1.0 Hardiflex 6.00 Pc 2.0 2x2x12 Lumber 63.00 Bd.ft 3.0 Asstd. Nails/screws 1.50 Kg Materials Preparation Area: 1.0 Hardiflex 3.00 Pc 2.0 2x2x12 Lumber 37.50 Bd.ft 3.0 Asstd. Nails/screws 1.00 Kg Labor: 1 Foreman 11.00 Day 2 Skilled Worker 12.00 Day 4 Laborer 11.00 Day 1032 Painting Works (concrete And Metal) Quantity: 853.04 Sq.m Materials: 1.0 Skimcoat 142.00 Bag 2.0 Flat Latex Primer 22.00 Gal 3.0 Semigloss Latex Paint 44.00 Gal 4.0 Turco Rust Converter 10.00 Gal 4.0 Epoxy Primer 15.00 Gal 6.0 Aluminum/epoxy Paint 30.00 Gal 5.0 Paint Thinner 1.00 Gal 6.0 Tinting Color 1.00 Gal Labor: 1 Foreman 7.00 Day 5 Skilled Worker 7.00 Day 4 Laborer 7.00 Day Spl 8 Electrical Works Quantity: 1.00 Lot Materials: 1.0 25at, 2p Circuit Breaker 5.00 Pc 2.0 40at, 2p Circuit Breaker 26.00 Pc 3.0 55at, 2p Circuit Breaker 14.00 Pc 4.0 225at, 2p Circuit Breaker 1.00 Pc 5.0 Panelboard 20 Branches 1.00 Unit 6.0 Pullbox 3.00 Pc 7.0 #12 3.5mm2 Thhn Wire 5.00 Box 8.0 #8 8.0mm2 Thhn Wire 150meters Box 7.00 Box 9.0 #4/0 100mm2 Thhn Wire 130.00 Mtr 10.0 Led Light Bulb 12w Daylight W/ Receptacle 24.00 Set 11.0 Led Fluorescent Light 18w With Fixtures 17.00 Set 12.0 Emt/rmc Pipe 2" 2.00 Pc 13.0 Emt/rmc Pipe 1/2" 22.00 Pc 14.0 Pvc Pipe 2" 26.00 Pc 15.0 Pvc Pipe 1" 10.00 Pc 16.0 Pvc Pipe 1/2" 12.00 Pc 17.0 Full Threaded Rod 4.00 Pc 18.0 Two-gang Convenience Outlet 23.00 Pc 19.0 One-gang Switch 16.00 Pc 20.0 Two-gang Switch 3.00 Pc 21.0 Juction Box 45.00 Pc 22.0 Utility Box 45.00 Pc Other Materials: 1.0 Solar Spotlight 3.00 Unit 2.0 Industrial Exhaust Fan Heavy Duty 1hp 3.00 Unit Labor: 4 Electrician 25.00 Day 2 Helper 25.00 Day 311 Pccp Quantity: 6.15 Cu.m. Materials: L=41lm : W =1.5m T = 0.10m 1.0 Aggregate Basecoarse 8.00 Cu.m. 2.0 Cement 62.00 Bag 3.0 Sand 5.00 Cu.m. 4.0 Gravel 8.00 Cu.m. 5.0 2" X 4" X 12' Form Lumber 20.00 Pc 6.0 Assorted Cwn 5.00 Kg Labor: 1 Foreman 6.00 Day 2 Skilled Worker 6.00 Day 2 Laborer 6.00 Day Equipment: 1 One-bagger Mixer 6.00 Day 1 Plate Compactor 8.00 Hr S U M M A R Y Item Description 0 Mobilization/demobilization 605 Project Signboard Spl - 1 Occupational Safety & Health Program 0 Survey And Staking 105 Subgrade Preparation 104 Embankment 201 Aggregate Base Course 803 Structure Excavation 804 Gravel Fill 901 Lean Concrete (2000 Psi) 900 Structural Concrete 902 Reinforcing Steel Bars, Grade 60 903 Formworks (scaffolding Included) Spl 2 Masonry Works Spl 3 Welded Wire Mesh (steel Matting) 110 Doors And Windows Spl 4 Roofing Works Spl 5 Steel Works (roof Framing) 1003 Ceiling Works (storage And Cr) Spl 6 Comfort Room (pipelines Included) Spl 7 Booth Partitions 1032 Painting Works (concrete And Metal) Spl - 2 Furnitures (benches/tables, Table, Chair, Shelves) Spl 8 Electrical Works 311 Pccp
Closing Date2 Dec 2024
Tender AmountPHP 3.5 Million (USD 61 K)
Department Of Labor And Employment Tender
Publishing and Printing
Philippines
Details: Description Lot A 23 Box Clearbook, A4 Size (piece)refillable, Material: Plastic, Cover: Opaque Plastic, Dimension: 310mm X 235mm (min.), Thickness: 0.5mm (min.), Pocket: Transparent Plastic, Number Of Pockets: Twenty (20), Thickness: 0.04 Mm (min.), Color: Assorted ( Black, Blue, Red, Yellow) 23 Box Clearbook, Legal Size (piece) Refillable, Material: Plastic, Cover: Opaque Plastic, Dimension: 345mm X 235mm (min.), Thickness: 0.04mm (min.), Color: Assorted ( Black, Blue, Red, Yellow) 30 Piece Eraser, Plastic/rubber (piece) Rectangular, Dimension (l X W X T) (min.): Equivalent Volume Of 8,350mm3 422 Piece Sign Pen, Extra Fine Tip, Black (piece) Ink Color: Black, Type: Liquid Or Gel, Tip: 0.5mm, Needle Type, One (1) Piece Barrel (non-refillable), Writing Length: One (1) Km (min) 172 Piece Sign Pen, Fine Tip, Black 182 Piece Sign Pen, Medium Tip, Black (piece) , Black (piece) Ink Color: Black, Type: Liquid Or Gel, Tip: 0.7mm, Needle Type, One (1) Piece Barrel (non-refillable), Writing Length: One (1) Km (min) 43 piece Sign Pen, Medium Tip, Blue(piece) , Blue(piece) Ink Color: Blue, Type: Liquid Or Gel, Tip: 0.7mm, Needle Type, One (1) Piece Barrel (non-refillable), Writing Length: One (1) Km (min) 1 pack "wrapping Paper, Kraft, Weight: 65gsm (-5%), Size: Width: 914.4mm (36"") (-3mm), Length: 1,219.4mm (48"") (-3mm)" 25 pack Battery, Dry Cell, Size Aa (pack) 1.5 Volts, Alkaline, Minimum Of Thirty (30) Minutes Runtime With A Current Draw Of 1.0 Amp Until Cut-off At One (1) Volt 19 pack Battery, Dry Cell, Size Aaa (pack)1.5 Volts, Alkaline, Minimum Of Thirty (30 Min.) Runtime With A Current Draw Of 0.5 Amp Until Cut-off At One (1) Volt, Shelf Life: Five (5) Years (min) From Date Of Acceptance 19 Bottle Ink, For Stamp Pad (bottle) Volume (min): 50ml, With Applicator, Shall Conform With The Required Perfamnce Test: Dry Time, Stability Test, Resistance To Water, Effect On Rubber Stamp, Corrosion Of Stamp-pad Container 2 Unit Digital Voice Recorder, Built-in Memory: 4gb (expandable), Channel: Stereo, Recording & Playback Format: Mp3, Wma, Earphone Jack, Built-in Microphone, Usb Connectivity, Battery Life 20 Hours (min) (recording Mode, Mp3 128kbps 2 Unit Fire Extinguisher, Dry Chemical, Capacity In Terms Of Mass Of Extinguisher Medium: 4.5kg (10lbs), Purity Of The Chemical: 75% (min.), Duration Of Discharge: 10 Seconds (min.) 5 Piece Philippine National Flag (piece) Type: 1, Size: Length: 1,828.8mm (6') (-3mm), Width: 914.4mm (3') (-3mm), Material: 100% Polyester, With Certificate Of Accreditation From National Historical Commission Of The Philippines (nhcp) 4 Unit "external Hard Drive (unit) Capacity: 1tb, Weight: 181 G - 205 G, Storage Media: 2.5""sata Hdd, Rotational Speed: 5400 Rpm, System Requirements: 1. Ms Windows 7, Ms Windows 8, Ms Windows 10, Mac Os 10.7 Or Later, Linux Kernel 2.6.31 Or Later, Antivirus: Pre-installed Antivirus (optional), Accessories: With Usb 3.0 Cable And Product Manual In English" 17 Piece Flash Drive (piece) 64gb Capacity 7 Unit Computer Mouse, Wireless (unit)connection Type: Usb, Tracking Method: Optical, Resolution: 1,000 Dpi (min), High-definition Optical: 2.5x More Responsive Than Standard Optical Mouse, 1000dpi High Technology Delivers Smoother, More Accurate Cursor Control 15 Piece Light-emitting Diode (led) Light Bulb, 7 Watts, Power Consumption: 7 Watts (max), Color Temperature: 6,500 Kelvin, Lumen Output: Not Less Than 530 Lumens, Frequency Rating: 60hz, Color Rendering Index: 80 +/-10%, Input Voltage: 220-240 Volts, Ac, Socket Base: E27, Light Color: Cool Daylight, Power Factor: Not Less Than 0.90, Average Life: Not Less Than 15,000 Hours, Operating Temperature: ≥ 35°c 73 jar Glue, All-purpose (bottle) Gross Weight (min.): 200 Grams, Free Formaldehyde(max.): 0.1%, Adhesive Strength - No Slippage On Pasted Part, Solid Content (min.): 30%, Ph: 4 To 8,container: Plastic Jar, Cap: Plastic Non-stick Easy Open Twist Top, With Tapered Applicator Attached To The Cap 42 box Staple Wire, Heavy Duty (binder Type), 23/13, Type: Chisel Point, Thickness: 0.60mm (-0.05), Width: 13mm (0.20), Leg Length: 13mm (-0.30), Number Of Staples Per Strip:100, Number Of Staples Per Box: 1,000, Binding Capacity: 40-90 Sheets Of 70gsm Multi-purpose Paper 201 box Staple Wire, Standard (box) 5000 Wires Per Box, Dimensions, In Mm: (see Fig. 1), Width (w): 12.70 +0.15mm/-0.20mm, Leg Length (l): 6.00 +0.50mm/-0.20mm, Thickness (d): 0.40 + 0.05mm, Width (e): 0.50 + 0.05mm, Number Of Wires Per Strip: 100 (min) 12 roll Tape, Electrical, Made Of Polyvinyl Chloride (pvc), Width: 18mm (min.), Length: 16 Meters (min.), Assorted Colors 36 roll Tape, Masking, 24mm (roll)width: 24mm (+1mm), Usable Length: 50 Meters, Adhesion Strength: 8.5n/24mm Width (min), Breaking Strength: 65n/24mm Width (min) 68 roll Tape, Masking, 48 Mm (roll) Width: 48mm (+1mm), Usable Length: 50 Meters, Adhesion Strength: 8.5/24mm Width (min), Breaking Strength: 65n/24mm Width (min) 70 roll Tape, Packaging, 48 Mm (roll) Color: Tan, Width: 48mm (+1mm), Usable Length: 50 Meters, Base Material: Biaxially-oriented Polypropylene, Adhesion Strength: 6n/24mm (min), Breaking Strength: 14n/24mm (min) 52 roll Tape, Transparent, 24mm (roll) Width: 24mm (+1mm), Usable Length: 50 Meters, Base Material: Biaxially-oriented Polypropylene, Adhesion Strength: 6n/24mm (min), Breaking Strength: 14n/24mm (min) 69 roll Tape, Transparent, 48 Mm (roll) Width: 48mm (+1mm), Usable Length: 50 Meters, Base Material: Biaxially-oriented Polypropylene, Adhesion Strength: 6n/24mm (min), Breaking Strength: 14n/24mm (min) 11 roll Twine, Plastic (roll) Weight Per Roll (min.): 1000g, Breaking Strength(min.): 25kg 20 piece Ruler, Plastic, 450mm (piece) Transparent/clear, Ruler Scale: Millimeters, Centimeters, Inches, Clear And Sharp Ruler Scales, Width: 38mm (min), Thickness: 1.30mm (min) 14 unit Calculator, Compact (unit) Width: 100mm - 130mm, Lcd Display, Capacity: 12 Digits, Two Way Power Source (solar And Cell) 10 boc Clip, Backfold, 15mm 87 box Clip, Backfold, 19mm (box) All Metal, Clamping Length: 19mm (-1mm), Clamping Depth: 10mm (min.), Thickness Of Metal: 0.20mm (min.), Diameter Of Clip Handles: 1.0mm (min.) 94 box Clip, Backfold, 25mm (box) All Metal, Clamping Length: 25mm (-1mm), Clamping Depth: 13mm (min.), Thickness Of Metal: 0.22mm (min.), Diameter Of Clip Handles: 1.20mm (min.) 36 box Clip, Backfold, 32mm (box) All Metal, Clamping Length: 32mm (-1mm), Clamping Depth: 14mm (-1mm) Thickness Of Metal: 0.30mm (min.), Diameter Of Clip Handles: 1.45mm (min.) 26 box Clip, Backfold, 50mm (box) All Metal, Clamping Length: 50mm (-1mm), Clamping Depth: 25mm (-1mm), Thickness Of Metal: 0.33mm (min.), Diameter Of Clip Handles: 1.85mm (min.) 252 piece Correction Tape (piece) Disposable, Dispensing Mechanism: Gear Type, Dispensing System: Single Line Tape 21 piece Cutter/utility Knife, For General Purpose (piece) Length: 100mm (+2mm), Width: 16mm (+2mm) Thickness: 0.40mm (+0.02mm) 85 piece Data File Box (piece) Outside Dimension: Width: 125mm (min), Height: 230mm (min), Length: 400mm (min), Material: Chipboard: 3mm Thick (min) 53 piece Data Folder (piece) Dimension: Width: 75mm (min), Height: 230mm (min), Length 380mm (min), Material: Chipboard: 2,5mm Thick (min) 11 piece Dater Stamp (piece) With Locking Mechanism, With Self-inking Stamp, With Removable And Refillable Ink Pad, Single Color, Size Of Imprint: 30mm X 45mm (min) 9 box Envelope, Documentary, A4 (box) 14 box Envelope, Documentary, Legal, (box) Size: 254mm X 381mm (-2mm), Basis Weight: 150gsm (-5%), Thickness (min.): 0.22mm 12 box Envelope, Expanding, Kraft (box) Legal Size: 380mm X 250mm (-3mm), Expansion: 50mm (-3mm), Thickness (min.): 0.38mm 4 box Envelope, Expanding, Plastic (box) 10 box Envelope, Mailing (box) 13 piece Eraser, Felt, For Blackboard/whiteboard (piece) Overall Size (l X W X T) (min.): 125mm X 45mm X 19mm 30 box Fastener, Metal (box) Thickness: Base With Prongs And Compressor: 0.30mm (min.), Material: As Per Sample Provided, Able To Hold 25mm Thick Of Multipurpose Paper (70gsm), 70mm Between Prongs 43 piece File Organizer, Expanding, Plastic, Legal (piece) With 12 Inside Pockets With Index Tab, For Legal Size Paper /documents, Dimension (min.): Cover (flap): Width: 220mm Length: 380mm Thickness: 0.60mm, Inside Pocket: Width: 230mm Length: 360mm Thickness: 0.12mm 49 pack "file Tab Divider, A4, For 210mm X 297mm (a4 Size) Documents, Size (min): Leaf: Length: 297mm Width: 210mm Tab: Length: 65mm Width: 12mm, Basis Weight: 153gsm (-5%), Thickness: 0.22mm (min.) " 37 pack Folder, L-type, Legal, Materials: Plastic, Size: 235mm X 346mm (min.) Thickness: (min.): 0.17mm, Transparent For Easy Identification Of Contents, Assorted Colors 3 box "folder, Pressboard (box) • Material: Heavy Duty Paper Board • Size: 369mm X 242mm (-smm) • Thickness: 0.40mm (min.) • Basis Weight: 312gsm (min.) • Color: Cream, Green Or Maroon, Etc. • Accordion-pleat Gusset: Latex Paper/pvc Bookbinder/book Cloth/paper Cloth, Color: Green, Red, Blue, Expansion: 39mm (-3mm)" 1 pack Folder With Tab, A4, Material: Tagboard/carrier/foldcote/cupstock Board, Leaf Dimension: 240mm X 320mm (+1mm), Tab: 13mm (+2mm), Scoring: 20mm From Edge Of Forlder (+2mm), Other Physical Properties: Grammage G/m²:308 (-5%), Thickness, Mm:0.35 (min), Tearing Resistance, Mn, Md + Cd 2940 (min), Stiffness, Mn.m, (taber) Md + Cd: 13 (min) 45 pack Folder With Tab, Legal (pack) Material: Tagboard/carrier/foldcote/cupstock Board, Leaf Dimension: 240mm X 320mm (+1mm), Tab: 13mm (+2mm), Scoring: 20mm From Edge Of Forlder (+2mm), Other Physical Properties: Grammage G/m²:308 (-5%), Thickness, Mm:0.35 (min), Tearing Resistance, Mn, Md + Cd 2940 (min), Stiffness, Mn.m, (taber) Md + Cd: 13 (min) 27 box "index Tab (box) Transparent, Self-adhesive, Assorted Colors, Five (5) Sets Per Box, One (1) Set Composed Of 2-pieces 6"" Tab Strip And Two (2) Complete Alphabets" 40 piece Magazine File Box, Large, Material: Chipboard: 3mm Thick (min.), Leatherette Paper For Outside Cover, Coated Paper For Inside Cover, Outside Dimension: :width: 110mm (min), Height: 265mm (min), Length: 220mm (min) 36 set Marker, Flourescent (set) Barrel: Flat, Tip: Chisel Point, Color: Three (3) Assorted Colors Per Set, Material And Structure: The Barrel And The Cap Shall Be Made Of Plastic And The Cap Shall Fit Snugly Or Firmly To The Barrel And Of Such Structure That Will Easily Cap And Uncap, Quality: Writing Performance: Flourescent Marker Shall Continuously Highlight On Multipurpose Paper For A Distance Of At Least 100 Meters Under Normal Pressure And Shall Not Show Noticeable Change In Ink Intensity. Cap-off Time: 45 Minutes (min) 225 piece Marker, Permanent, Black (piece) Ink Color: Black, Tip: Felt, Bullet Type, Point: Medium, Structure: The Barrel And The Cap Shall Fit Snugly Or Firmly To The Barrel And Os Such Structure That Shall Easily Cand And Uncap 80 piece Marker, Permanent, Blue (piece) Ink Color: Blue, Tip: Felt, Bullet Type, Point: Medium, Structure: The Barrel And The Cap Shall Fit Snugly Or Firmly To The Barrel And Os Such Structure That Shall Easily Cand And Uncap 86 piece Marker, Whiteboard, Black (piece) Ink Color: Black, Blue, Red, Tip: Felt, Bullet Type, Structure: The Barrel And The Cap Shall Fit Snugly Or Firmly To The Barrel And Of Such Structure That Shall Easily Cand And Uncap 19 piece Marker, Whiteboard, Red, Ink Color: Red, Tip: Felt, Bullet Type, Structure: The Barrel And The Cap Shall Fit Snugly Or Firmly To The Barrel And Of Such Structure That Shall Easily Cand And Uncap 76 box Paper Clip, Vinly/plastic Coated, 33mm (box) Wire Diameter: 0.80mm (min), Length Of Clip: 33mm (min), Total Length Of Wire Used: 102mm (min), Assorted Colors 100 Box Paper Clip, Vinly/plastic Coated, Jumbo, 50mm (box) Wire Diameter: 1.0mm (min), Length Of Clip: 50mm (min), Total Length Of Wire Used: 155mm (min), Assorted Colors 19 Box Pencil, Lead/graphite, With Eraser, Hardness: Hb Or 2, Lead/graphite Diameter: 2mm (min), Wood Casing: Softwood, Coated, Free From Defects As Cross Grains, Interlocked Grains, Warpage Knots And The Like; And Shall Permit Easy Sharpening 11 Piece Pencil Sharpener, Table Mountable Type, With Metal Clamp, Single Cutter-head, One Hole Guide, 9-10mm In A Diameter, All Main Parts Shall Be Made Of Metal Particularly The Cutting Mechanism Cutter,pinion Gear,internal Gear,handle 23 Piece Puncher, Paper, Heavy Duty (piece) Punching Capacity: 30 Sheets Of 70gsm Multipurpose Paper, With Two Hole Guide, Diameter Of Hole: 7mm (approx) 19 Box Rubber Band No. 18 (box) 35o Grams (min) (net Weight), Thickness: 1.00mm (min), Lay Flat Length: 70mm (min), Tensile Strength: 9.81mpa (min), Elongation: 250% (min) 31 Piece Stamp Pad, Felt (piece) Thickness Of Felt: 5mm (min.), Thickness Of Metal: 0.20mm (min.), Stamp Bed Size: Width: 60mm (min.), Length: 100mm (min.) 68 Pair Scissors, Symmetrical/asymmetrical (pair) Overall Length: 160mm (min), Length Of The Cutting Blade: 70mm (min), Thickness Of The Cutting Blade: 1.70mm (min), Length Of Metal Handle (measured From The Center Of The Binding Rivet Screw To The Tip Of The Metal Handle): 35mm (min) 37 Piece Stapler, Standard Type (piece) Loading Capacity: 200 Staples (min), One Time Binding Capacity Of 2-20 Sheets Multi-purpose Paper (70gsm)r 6 Unit Stapler, Heavy Duty (binder) (unit) Type: Desktop, High Capacity/volume, Compatible With The Following Staple Sizes: 13mm And 17mm, Material: Body: Metal, Bases Grip: Non-skid Durable Material, Stapling Capacity: 25-135 Sheets Of 70gsm Multi-purpose Paper, Load Capacity: 100 Staples (min), Throat: Depth: 65mm (min) With Adjustable Paper Guide, Dimension: Manufacturer's Standard 9 Piece Tape Dispenser, Table Top (piece) Net Weight (min.): 1.2kg, Body Made Of Rigid Plastic, Smooth Finish: Weighted, Serrated Cutting Blade Thickness: 0.40mm +0.03mm, Holds Rolls Up To 24mm Wide On 75mm Core, Assorted Color 17 Pack Cartolina, Assorted Colors (pack) Bristol Board, Size: 572mm X 724mm (-3mm), Basis Weight: 100gsm (min.), Thickness: 0.12mm (min.), Assorted Colors: Blue, Green, Yellow, Orange, Lavender, Violet, Gold And Pink, Minimum Of Four (4) Colors 158 Pad "notepad, Stick-on, 50mm X 76mm (pad) Size: 50mm X 76mm (2"" X 3"") (min), Basis Weight: 70gsm (min), Sheet Thickness: 0.09mm (min), Assorted Colors" 175 Pad "notepad, Stick-on, 76mm X 100mm (pad) Size: 76mm X 100mm (3"" X 4"") (min), Basis Weight: 70gsm (min), Sheet Thickness: 0.09mm (min), Assorted Colors" 98 Pad "notepad, Stick-on, 76mm X 76mm (pad) Size: 76mm X 76mm (3"" X 3"") (min), Basis Weight: 70gsm (min), Sheet Thickness: 0.09mm (min), Assorted Colors" 153 Piece Steno Notebook (piece) Basis Weight: 55gsm (-5%) Bond, Thickness: 0.075mm (min), Size: 150mm X 225mm, (min), Top Margin: 25mm (min.), Bottom Margin: 5mm, Number Of Spaces: 22 (min), Cover Thickness: 0.40mm (-0.02mm), 40 Leaves, Ruled Both Sides 40 Bond Paper , Legal, 70 Gsm 40 Ream Bond Paper , A4, 70 Gsm 591 Ream Paper, Multicopy A4 (ream) Basis Weight: 80gsm (-3%), Size: A4, 210mm X 297mm (+2mm In Either Direction), Trim Sizes Shall Be Along Machine Direction Or Long Grain 156 Ream Paper, Multicopy Legal (ream) Basis Weight: 80gsm (-3%), Size: Legal, 216mm X 330mm (+2mm In Either Direction), Trim Sizes Shall Be Along Machine Direction Or Long Grain 419 Ream Paper, Multipurpose A4, Basis Weight: 80gsm (min.), Size: Legal, 216mm X 330mm (+2mm In Either Direction), Trim Sizes Shall Be Along Machine Direction Or Long Grain 93 Ream Paper, Multipurpose Legal, Basis Weight: 80gsm (min.), Size: Legal, 216mm X 330mm (+2mm In Either Direction), Trim Sizes Shall Be Along Machine Direction Or Long Grain 15 Box Paper, Parchment, Size: 210mm X 297mm (+2mm In Either Direction), Basis Weight: 80gsm (-5%), Fine Translucent, Suitable For Laser/inkjet Printing 48 Book Record Book, 300 Pages (book) Basis Wieght: 55gsm (-5%), Thickness: 0.07mm (minimum), Size: L X W: 265mm X 165mm (minimum), Cover Material: Laminated Chipboard, Thickness: 1.5mm (minimum) Size: L X W: 278mm X 175mm (minimum), Margins Top: 25mm (-2mm), Bottom: 8mm (+4mm), Left / Right: Manufacturer's Standard 37 Book "record Book, 500 Pages (book) Basis Weight: 55 Gsm (-5%) Thickness 0.07 Mm (minimum) Size L X W: 265mm X 165mm (minimum) Cover Material Laminated Chipboard Thickness 1.5mm (minimum) Size L X W: 278mm X 175mm (minimum) Margins Top 25mm (-2mm) Bottom 8mm (±4mm) Left / Right Manufacturer’s Standard" 35 Cart Ink Cartridge, Epson C13t664100 (t6641), Black 30 Cart Ink Cartridge, Epson C13t664200 (t6642), Cyan 30 Cart Ink Cartridge, Epson C13t664300 (t6643), Magenta 30 Cart Ink Cartridge, Epson C13t664400 (t6644), Yellow 1054 piece Ballpen 36 pack Sticker Paper , A4, Matte, White, 10 Pcs/pack 21 pack Sticker Paper , Legal, Matte, White, 10 Pcs/pack 25 roll Double Sided Tape 31 pack Photo Paper, A4 Size, Glossy, 10 Sheets/pack 15 packs Photo Paper Legal 4 bottle Disinfectant Bleaching Solution, 3.78 Lit 67 piece Certificate Frame, A4, Orientation: Landscape, Pvc Black 195 piece Certificate Holder, A4, Plastic 1 unit Microphone 74 box Plastic Fastener, Size: Regular (50pcs/box) 14 box Plastic Fastener, Size: Long 2 piece Extension Cord 2 pack Push Pin 12 piece Glue Stick (paste) 5 pack Glue Stick (for Glue Gun) 2 unit Ergonomic Chair, (midback Synthetic Leather Finished Office Chair- Padded Steel Armrest With Heavy Duty Base With Nylon Caster Wheels, With Pneumatic Gaslift For Height Adjustment) 1 unit Executive Chair (for Fo Head) 2 unit Glue Gun 2 unit Speakers 113 bottle Ink Cartridge, Epson 003 Yellow 109 bottle Ink Cartridge, Epson 003 Magenta 109 bottle Ink Cartridge, Epson 003 Cyan 131 bottle Ink Cartridge, Epson 003 Black 10 bottle Ink Cartridge, Hp Gt52 Yellow 10 bottle Ink Cartridge, Hp Gt52 Magenta 10 bottle Ink Cartridge, Hp Gt52 Cyan 10 bottle Ink Cartridge, Hp Gt53 Black 18 bottle Ink, Brother, Black, Btd60bk, 108ml 9 bottle Ink, Brother, Cyan, Bt5000c, 48.8ml 9 bottle Ink, Brother, Yellow, Bt5000c, 48.8ml 6 bottle Ink, Brother, Magenta, Bt5000c, 48.8ml 37 bottle Ink Refill, Epson Ink 001, Black, 127ml 29 bottle Ink Refill, Epson Ink 001, Cyan, 65ml 29 bottle Ink Refill, Epson Ink 001, Magenta, 65ml 29 bottle Ink Refill, Epson Ink 001, Yellow, 65ml 5 Box Sign Pen, Uniball-impact Gel, Ruber Grip, Steel Point, Water-based Pigment Gel Ink 1.0% Ball, Approx 0.6% Line, 12 Pcs/box 58 Piece Sign Penm Black, Gel 0.7mm 12 Piece Sign Pen, Ink Refill, 0.5, My Gel 3 Meter Pdx Loomex Wire 2 Cart Tonner (5501i, No. Tk6309) 12 Packs Notarial Seal Box Notarial Seal (gold), No. 23, 25pcs/box 1 Piece Glass Top Corner Table 2 Piece Steel Filing Cabinet Four Drawers, Vertical 15 Packs Specialty Board, A4 21 Pad Sign Here Sticky Note Pad 30 Packs Specialty Paper, A4 Lot B 58 Bottle Alcohol, Ethyl, 500 Ml, 68% - 72% Ethyl Alcohol, Fully Miscible In Water, Flip-top Cap, Scented 49 Gallon Alcohol, Ethyl, 1 Gallon, , Strength: 68% - 72%, Volume: 1 Gallon, Bottle: Hdpe 51 Can Air Freshener (can) Aerosol Type, Net Content: 150g (min), Assorted Scents (at Least Three (3) Scents), Long Lasting Fragrance (scent Trace Lingers For Atleast 5 Min.) 10 Piece Broom (walis Tambo) (piece)weight: 500 Grams (max), Handle: Plastic Coated Aluminum Tube, Diameter Of Handle: 19mm (min), Length Of Handle: 545mm (min), Dry Weight Of The Tiger Grass: 200grams (min), Usable Length Of Tiger Grass: 300mm (min), With Upper Stitch: 20 (min) Lower Stitch: 30 (min) 5 Piece Broom (walis Ting-ting) (piece) Made Of Mature Coconut Midribs, Standard Size (min.): 140mm Grip, Measured 150mm From The Top,usable Length (min.): 760mm, Rib Count (min.): 350 Pieces 55 Bottle Cleaner, Toilet Bowl And Urinal (bottle) Color: Cear Or Blue, Net Content: 900ml - 1000ml In Rigid Plastic Bottle, Not Chlorine Based, Viscosity: 114cp At 25°c Min Using Ostwald Method 15 Bar Detergent Bar (piece) Net Weight: 140 Grams As Packed (-2.5%) 30 Pouch Detergent Powder, All-purpose, 1kg, Net Weight: One (1) Kilogram (-2.5%) 51 Can Disinfectant Spray (can) Aerosol Type, Net Content Per Can: 400 Grams (min), Crisp, Clean Scent 11 Piece Dust Pan (piece) Made Of Rigid Non-breakable Plastic, With Detachable Handle: Diameter (min.): 30mm, Length (min.): 600mm, Base (min.): Thickness: 1.25mm, Front Width: 260mm, Back Width: 200mm, Depth: 225mm 13 Can "furniture Cleaner (can) Aerosol Type • For All Types Of Surfaces Such As Furniture, Cabinets And Countertops, Vinyl And Leather, Etc. • Net Content (min.): 300mi Per Can • Pleasant Smell. • Sufficient Amount Of Propellant To Totally Expel Content. • Shelf Life: Must Have A Shelf Life Of At Least Twenty-four (24) Months From The Date Of Manufacture But Not Less Than Eighteen (18) Months From The Date Of Delivery" 48 Bottle Hand Soap, Liquid, 500ml (bottle) Mild Scented, Bactericidal/germicidal Property, Individual Packed Plastic Bottle, Packaging: Standard Packaging Of The Manufacture 1 Unit Mop Bucket, Heavy Duty, Hard Plastic, Material: Hard Palstic, Approximate Size (min.), Width: 370mm Length: 475mm Height: 245mm, Capacity: 30 Liters 4 Piece Mophandle, Heavy Duty, Screw Type, Screw Type, With Metal Mop Head Clipper, Aluminum Handle: Thickness (min.): 0.70mm, Outside Diameter: 22mm To 25mm Length (min.): 1.5 Meters 10 Piece Mophead, Made Of Rayon, 36 Stands Per Head (min), 3 Ply's Per Stand, 40 Threads Per Ply, Weight:400 Grams (min), Length: 410mm (min), Length Of Band: 170mm (min), Breaking Strength, Kg: 126 (min) 5 Kilo "rags All Cotton (bundle) Diameter: 178mm (7"") (approx.) Minimum Of Thirty-two (32) Pieces To A Kilogram, Assorted Colors" 7 Pack Scouring Pad (pack) Made Of Synthetic Nylon, 150mm X 200m (min.), Thickness (min.): 8mm, Color: Green 56 Pack/roll "trashbag, Xxl Size (roll/pack) Color: Black, Dimension: 940mm X 1016mm (-6mm) (37"" X 40""), Thickness: 0.02mm (min), Tensile Strength At Break: Astm D882, One Way: 15n/mm² (min), Other Way: 12n/mm² (min), Elongation At Break: Astm D882, One Way: 400% (min), Other Way: 600% (min)" 54 Pack/roll Trashbag, Large Size (roll/pack) 29 Pack/roll Trashbag, Xl Size (roll/pack) 19 Piece Wastebasket, Non-rigid Plastic, Made Of Rigid Plastic, Thickness (min.): 1.20mm, Height (min.): 225mm, Full Volume (up To The Lid): 8.5 Liters (min.), Assorted Colors 44 bottle Dishwashing Liquid Lemon/calamansi 25 pcs Dishwashing Paste, 200g 34 Pack Tissue, Interfolded Paper Towel (pack) Basis Weight: 34gsm (+/-2gsm), Sheet Dimension: Width Of Sheet: 200mm (+3mm), Length Of Sheet: 200mm (+3mm), Total Number Of Sheets Per Pack: 150 Pulls, Interfolded, Number Of Ply: One (1) Ply 164 Pack Toilet Tissue Paper, 2 Ply (pack) , 100% Recycled, 12 Rolls Per Pack, Weight: 28gsm (min.), Sheet Dimension: Width Of Sheet: 100mm (+/-3mm), Length Of Sheet: 114mm (-5mm) 18 Bottle Hand Sanitizer (bottle) Form: Liquid Or Gels, Volume: 500ml, Hypoallergenic, Non-drying, Bottle: Pump Dispenser Plastic, Fda Certificate Of Product Registration/notification 20 Can Insecticide (can) Aerosol, Kerosene Based, Quick Kill Contact And Residual Type, Cautionary Scent/odor Required, Multi-insect Killer, Net Content Per Can: 600ml (min.) 41 piece Toilet Deodorant Cake, Assorted, 100grms 6 Pcs Doormat Xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Closing Date9 Dec 2024
Tender AmountPHP 1.1 Million (USD 19 K)
Province Of Iloilo Tender
Laboratory Equipment and Services
Philippines
Details: Description Bids And Awards Committee Iloilo Provincial Government Procurement Of Laboratory Supplies Bid No. Iph-24-1467-b Philippine Bidding Documents Sixth Edition July 2020 Table Of Contents Section I. Invitation To Bid 3 Section Ii. Instructions To Bidders 5 1. Scope Of Bid 5 2. Funding Information 5 3. Bidding Requirements 5 4. Corrupt, Fraudulent, Collusive, And Coercive Practices 5 5. Eligible Bidders 5 6. Origin Of Goods 6 7. Subcontracts 6 8. Pre-bid Conference 7 9. Clarification And Amendment Of Bidding Documents 7 10. Documents Comprising The Bid: Eligibility And Technical Components 7 11. Documents Comprising The Bid: Financial Component 7 12. Bid Prices 8 13. Bid And Payment Currencies 8 14. Bid Security 8 15. Sealing And Marking Of Bids 9 16. Deadline For Submission Of Bids 9 17. Opening And Preliminary Examination Of Bids 9 18. Domestic Preference 9 19. Detailed Evaluation And Comparison Of Bids 9 20. Post-qualification 10 21. Signing Of The Contract 10 Section Iii. Bid Data Sheet 11 Section Iv. General Conditions Of Contract 12 1. Scope Of Contract 12 2. Advance Payment And Terms Of Payment 12 3. Performance Security 12 4. Inspection And Tests 12 5. Warranty 13 6. Liability Of The Supplier 13 Section V. Special Conditions Of Contract 14 Section Vi. Schedule Of Requirements 16 Section Vii. Technical Specifications 18 Section Viii. Checklist Of Technical And Financial Documents 20 Section I. Invitation To Bid Purchase Of Laboratory Supplies Bid No. Iph-24-1467-b 1. The Iloilo Provincial Government Through The Supplemental Budget No. 1 Cy 2024 Intends To Apply The Sum Of One Million Five Hundred Ninety-two Thousand Four Hundred Pesos (php 1,592,400.00) Being The Abc To Payments Under The Contract For The Purchase Of Laboratory Supplies Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The Iloilo Provincial Government Now Invites Bids For The Above Procurement Project. Delivery Of The Goods Is Required By 14 Days Upon Receipt Of The Notice To Proceed (ntp). Bidders Should Have Completed, Within Three (3) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From The Bids And Awards Committee Secretariat Of The Iloilo Provincial Government And Inspect The Bidding Documents At The Address Given Below During 8:00 A.m. To 5:00 P.m. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On November 20, 2024 From The Given Address And Website(s) Below And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of One Thousand Pesos (php1,000.00). The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees In Person. 6. The Iloilo Provincial Government Will Hold A Pre-bid Conference On November 27, 2024 At The Bac Office, 5th Floor, New Iloilo Provincial Capitol And/or Through Video Conferencing Or Webcasting, Upon Request At Least Three (3) Days Before The Pre-bid Conference, Via Zoom Or Other Videoconferencing Portals, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Bac Office,5th Floor, Iloilo Provincial Capitol, Bonifacio Drive, Iloilo City On Or Before December 11, 2024 At 9:00 A.m. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On December 11, 2024 At 9:01 A.m. At The Bac Office, 5th Floor, New Iloilo Provincial Capitol. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. A. The Participating Bidder/supplier Or Its Authorized Representative Must Indicate In Any Of The Eligibility Documents, An Email Address Or A Working Fax Number. The Absence Of Which Shall Be A Ground For Disqualification. Notice To The Bidder/supplier Through The Use Of Either Of These Means (email/fax) Is Considered Sufficient Notice. The Date Of Filing Of Reconsideration And All Communications With The Bac Shall Be Its (bac) Date Of Receipt. B. The Bidder(s)/awardee(s) Or Its Authorized Representative Must Conform To The Notice Of Award Within Three (3) Calendar Days From Receipt Of Such Notice And The Winning Bidder Shall Post The Required Performance Security And Enter Into Contract With The Procuring Entity Within Ten (10) Calendar Days From Receipt By The Winning Bidder Of The Notice Of Award In Accordance With Section 37.2.1 Of The Revised Irr Of R.a. No. 9184. C. The Bidder/supplier Must Have No Pending Unaccepted Notice To Proceed Three (3) Days From The Date Of Acceptance And Signing Of The Purchase Order. Otherwise, It Shall Be A Ground For Disqualification And The Bidder Will Be Rated "failed" During The Preliminary Examination Of Bids And/or Its Bid Shall Be Declared As "non-responsive" During Post-qualification. D. The Bidder/supplier Must Have No Notice Of Award Pending Its Conformity Three (3) Days From The Date Of Its Receipt Of The Notice Of Award. Otherwise, It Shall Be Aground For Disqualification And The Bidder Will Be Rated "failed" During The Preliminary Examination Of Bids And/or Its Bid Shall Be Declared As "non-responsive" During Post-qualification. E. The Bidder/supplier Shall Submit A List Of All Its Ongoing And Completed Projects With The Iloilo Provincial Government Indicating The Delivery Periods And Accomplishments Of Such Projects. F. The Bidder/supplier At The Time Of The Bidding Must Have No Pending Unposted Performance Or Warranty Security, As The Case May Be, Beyond The Period Allowed In The Notice Of Award. Otherwise, It Shall Be A Ground For Disqualification And The Bidder Will Be Rated "failed" During The Preliminary Examination Of Bids And/or Its Bid Shall Be Declared As "non-responsive" During Post-qualification. G. When An Occurrence Of A Tie Among Bidders Takes Place, I.e., Two Or More Of The Bidders Are Determined And Declared As The Lowest Calculated And Responsive Bidder (lcrb), The Winning Bidder Shall Be Determined By Draw Lots Upon Notice To The Bidders Concerned And/or Their Authorized Representatives In Accordance With The Relevant Circulars Issued By The Government Procurement Policy Board (gppb). 11. The Iloilo Provincial Government Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 12. For Further Information, Please Refer To: Atty. Raemman M. Lagrada Bac Secretariat Head 5th Floor, Bids And Awards Committee Iloilo Provincial Capitol Email Address: Ipg_bacs@yahoo.com Website: Iloilo.gov.ph Telephone Number: (033) 336-0736 13. You May Visit The Following Websites For Downloading Of Bidding Documents: Ipg.gov.ph And/or Philgeps.com November 14, 2024 Atty. Dennis T. Ventilacion Chairman, Bids And Awards Committee Section Ii. Instructions To Bidders 1. Scope Of Bid The Procuring Entity, Iloilo Provincial Government Wishes To Receive Bids For The Purchase Of Laboratory Supplies With Bid No. Iph-24-1467-b. The Procurement Project (referred To Herein As “project”) Is Composed Of Forty-four (44) Items, The Details Of Which Are Described In Section Vii (technical Specifications). 2. Funding Information 2.1. The Gop Through The Source Of Funding As Indicated Below For 2024 In The Amount Of One Million Five Hundred Ninety-two Thousand Four Hundred Pesos (php 1,592,400.00). The Source Of Funding Is: A. Lgus, The Annual Or Supplemental Budget, As Approved By The Sanggunian. 3. Bidding Requirements The Bidding For The Project Shall Be Governed By All The Provisions Of Ra No. 9184 And Its 2016 Revised Irr, Including Its Generic Procurement Manuals And Associated Policies, Rules And Regulations As The Primary Source Thereof, While The Herein Clauses Shall Serve As The Secondary Source Thereof. Any Amendments Made To The Irr And Other Gppb Issuances Shall Be Applicable Only To The Ongoing Posting, Advertisement, Or Ib By The Bac Through The Issuance Of A Supplemental Or Bid Bulletin. The Bidder, By The Act Of Submitting Its Bid, Shall Be Deemed To Have Verified And Accepted The General Requirements Of This Project, Including Other Factors That May Affect The Cost, Duration And Execution Or Implementation Of The Contract, Project, Or Work And Examine All Instructions, Forms, Terms, And Project Requirements In The Bidding Documents. 4. Corrupt, Fraudulent, Collusive, And Coercive Practices The Procuring Entity, As Well As The Bidders And Suppliers, Shall Observe The Highest Standard Of Ethics During The Procurement And Execution Of The Contract. They Or Through An Agent Shall Not Engage In Corrupt, Fraudulent, Collusive, Coercive, And Obstructive Practices Defined Under Annex “i” Of The 2016 Revised Irr Of Ra No. 9184 Or Other Integrity Violations In Competing For The Project. 5. Eligible Bidders 5.1. Only Bids Of Bidders Found To Be Legally, Technically, And Financially Capable Will Be Evaluated. 5.2. A. Foreign Ownership Exceeding Those Allowed Under The Rules May Participate Pursuant To: I. When A Treaty Or International Or Executive Agreement As Provided In Section 4 Of The Ra No. 9184 And Its 2016 Revised Irr Allow Foreign Bidders To Participate; Ii. Citizens, Corporations, Or Associations Of A Country, Included In The List Issued By The Gppb, The Laws Or Regulations Of Which Grant Reciprocal Rights Or Privileges To Citizens, Corporations, Or Associations Of The Philippines; Iii. When The Goods Sought To Be Procured Are Not Available From Local Suppliers; Or Iv. When There Is A Need To Prevent Situations That Defeat Competition Or Restrain Trade. 5.3. Pursuant To Section 23.4.1.3 Of The 2016 Revised Irr Of Ra No.9184, The Bidder Shall Have An Slcc That Is At Least One (1) Contract Similar To The Project The Value Of Which, Adjusted To Current Prices Using The Psa’s Cpi, Must Be At Least Equivalent To: A. For The Procurement Of Non-expendable Supplies And Services: The Bidder Must Have Completed A Single Contract That Is Similar To This Project, Equivalent To At Least Fifty Percent (50%) Of The Abc. B. For The Procurement Of Expendable Supplies: The Bidder Must Have Completed A Single Contract That Is Similar To This Project, Equivalent To At Least Twenty-five Percent (25%) Of The Abc. C. For Procurement Where The Procuring Entity Has Determined, After The Conduct Of Market Research, That Imposition Of Either (a) Or (b) Will Likely Result To Failure Of Bidding Or Monopoly That Will Defeat The Purpose Of Public Bidding: The Bidder Should Comply With The Following Requirements: [select Either Failure Or Monopoly Of Bidding Based On Market Research Conducted] I. Completed At Least Two (2) Similar Contracts, The Aggregate Amount Of Which Should Be Equivalent To At Least Fifty Percent (50%) In The Case Of Non-expendable Supplies And Services Or Twenty-five Percent (25%) In The Case Of Expendable Supplies] Of The Abc For This Project; And Ii. The Largest Of These Similar Contracts Must Be Equivalent To At Least Half Of The Percentage Of The Abc As Required Above. 5.4. The Bidders Shall Comply With The Eligibility Criteria Under Section 23.4.1 Of The 2016 Irr Of Ra No. 9184. 6. Origin Of Goods There Is No Restriction On The Origin Of Goods Other Than Those Prohibited By A Decision Of The Un Security Council Taken Under Chapter Vii Of The Charter Of The Un, Subject To Domestic Preference Requirements Under Itb Clause 18. 7. Subcontracts 7.1. The Bidder May Subcontract Portions Of The Project To The Extent Allowed By The Procuring Entity As Stated Herein, But In No Case More Than Twenty Percent (20%) Of The Project. The Procuring Entity Has Prescribed That: Subcontracting Is Not Allowed. 8. Pre-bid Conference The Procuring Entity Will Hold A Pre-bid Conference For This Project On The Specified Date And Time And Either At Its Physical Address As Indicated In Paragraph 6 Of The Ib. 9. Clarification And Amendment Of Bidding Documents Prospective Bidders May Request For Clarification On And/or Interpretation Of Any Part Of The Bidding Documents. Such Requests Must Be In Writing And Received By The Procuring Entity, Either At Its Given Address Or Through Electronic Mail Indicated In The Ib, At Least Ten (10) Calendar Days Before The Deadline Set For The Submission And Receipt Of Bids. 10. Documents Comprising The Bid: Eligibility And Technical Components 10.1. The First Envelope Shall Contain The Eligibility And Technical Documents Of The Bid As Specified In Section Viii (checklist Of Technical And Financial Documents). 10.2. The Bidder’s Slcc As Indicated In Itb Clause 5.3 Should Have Been Completed Within Three (3) Years Prior To The Deadline For The Submission And Receipt Of Bids. 10.3. If The Eligibility Requirements Or Statements, The Bids, And All Other Documents For Submission To The Bac Are In Foreign Language Other Than English, It Must Be Accompanied By A Translation In English, Which Shall Be Authenticated By The Appropriate Philippine Foreign Service Establishment, Post, Or The Equivalent Office Having Jurisdiction Over The Foreign Bidder’s Affairs In The Philippines. Similar To The Required Authentication Above, For Contracting Parties To The Apostille Convention, Only The Translated Documents Shall Be Authenticated Through An Apostille Pursuant To Gppb Resolution No. 13-2019 Dated 23 May 2019. The English Translation Shall Govern, For Purposes Of Interpretation Of The Bid. 11. Documents Comprising The Bid: Financial Component 11.1. The Second Bid Envelope Shall Contain The Financial Documents For The Bid As Specified In Section Viii (checklist Of Technical And Financial Documents). 11.2. If The Bidder Claims Preference As A Domestic Bidder Or Domestic Entity, A Certification Issued By Dti Shall Be Provided By The Bidder In Accordance With Section 43.1.3 Of The 2016 Revised Irr Of Ra No. 9184. 11.3. Any Bid Exceeding The Abc Indicated In Paragraph 1 Of The Ib Shall Not Be Accepted. 11.4. For Foreign-funded Procurement, A Ceiling May Be Applied To Bid Prices Provided The Conditions Are Met Under Section 31.2 Of The 2016 Revised Irr Of Ra No. 9184. 12. Bid Prices 12.1. Prices Indicated On The Price Schedule Shall Be Entered Separately In The Following Manner: A. For Goods Offered From Within The Procuring Entity’s Country: I. The Price Of The Goods Quoted Exw (ex-works, Ex-factory, Ex-warehouse, Ex-showroom, Or Off-the-shelf, As Applicable); Ii. The Cost Of All Customs Duties And Sales And Other Taxes Already Paid Or Payable; Iii. The Cost Of Transportation, Insurance, And Other Costs Incidental To Delivery Of The Goods To Their Final Destination; And Iv. The Price Of Other (incidental) Services, If Any, Listed In E. B. For Goods Offered From Abroad: I. Unless Otherwise Stated In The Bds, The Price Of The Goods Shall Be Quoted Delivered Duty Paid (ddp) With The Place Of Destination In The Philippines As Specified In The Bds. In Quoting The Price, The Bidder Shall Be Free To Use Transportation Through Carriers Registered In Any Eligible Country. Similarly, The Bidder May Obtain Insurance Services From Any Eligible Source Country. Ii. The Price Of Other (incidental) Services, If Any, As Listed In Section Vii (technical Specifications). 13. Bid And Payment Currencies 13.1. For Goods That The Bidder Will Supply From Outside The Philippines, The Bid Prices May Be Quoted In The Local Currency Or Tradeable Currency Accepted By The Bsp At The Discretion Of The Bidder. However, For Purposes Of Bid Evaluation, Bids Denominated In Foreign Currencies, Shall Be Converted To Philippine Currency Based On The Exchange Rate As Published In The Bsp Reference Rate Bulletin On The Day Of The Bid Opening. 13.2. Payment Of The Contract Price Shall Be Made In: Philippine Pesos. 14. Bid Security 14.1. The Bidder Shall Submit A Bid Securing Declaration Or Any Form Of Bid Security In The Amount Indicated In The Bds, Which Shall Be Not Less Than The Percentage Of The Abc In Accordance With The Schedule In The Bds. 14.2. The Bid And Bid Security Shall Be Valid Until One Hundred Twenty (120) Days. Any Bid Not Accompanied By An Acceptable Bid Security Shall Be Rejected By The Procuring Entity As Non-responsive. 15. Sealing And Marking Of Bids Each Bidder Shall Submit One Copy Of The First And Second Components Of Its Bid. The Procuring Entity May Request Additional Hard Copies And/or Electronic Copies Of The Bid. However, Failure Of The Bidders To Comply With The Said Request Shall Not Be A Ground For Disqualification. 16. Deadline For Submission Of Bids 16.1. The Bidders Shall Submit On The Specified Date And Time At Its Physical Address As Indicated In Paragraph 7 Of The Ib. 17. Opening And Preliminary Examination Of Bids 17.1. The Bac Shall Open The Bids In Public At The Time, On The Date, And At The Place Specified In Paragraph 9 Of The Ib. The Bidders’ Representatives Who Are Present Shall Sign A Register Evidencing Their Attendance. In Case Videoconferencing, Webcasting Or Other Similar Technologies Will Be Used, Attendance Of Participants Shall Likewise Be Recorded By The Bac Secretariat. In Case The Bids Cannot Be Opened As Scheduled Due To Justifiable Reasons, The Rescheduling Requirements Under Section 29 Of The 2016 Revised Irr Of Ra No. 9184 Shall Prevail. 17.2. The Preliminary Examination Of Bids Shall Be Governed By Section 30 Of The 2016 Revised Irr Of Ra No. 9184. 18. Domestic Preference 18.1. The Procuring Entity Will Grant A Margin Of Preference For The Purpose Of Comparison Of Bids In Accordance With Section 43.1.2 Of The 2016 Revised Irr Of Ra No. 9184. 19. Detailed Evaluation And Comparison Of Bids 19.1. The Procuring Bac Shall Immediately Conduct A Detailed Evaluation Of All Bids Rated “passed,” Using Non-discretionary Pass/fail Criteria. The Bac Shall Consider The Conditions In The Evaluation Of Bids Under Section 32.2 Of The 2016 Revised Irr Of Ra No. 9184. 19.2. If The Project Allows Partial Bids, Bidders May Submit A Proposal On Any Of The Lots Or Items, And Evaluation Will Be Undertaken On A Per Lot Or Item Basis, As The Case Maybe. In This Case, The Bid Security As Required By Itb Clause 15 Shall Be Submitted For Each Lot Or Item Separately. 19.3. The Descriptions Of The Lots Or Items Shall Be Indicated In Section Vii (technical Specifications), Although The Abcs Of These Lots Or Items Are Indicated In The Bds For Purposes Of The Nfcc Computation Pursuant To Section 23.4.2.6 Of The 2016 Revised Irr Of Ra No. 9184. The Nfcc Must Be Sufficient For The Total Of The Abcs For All The Lots Or Items Participated In By The Prospective Bidder. 19.4. The Project Shall Be Awarded As Follows: Complete Bid - One Project Having Several Items That Shall Be Awarded As One Contract In Case Of Complete Bid. Line Bidding/partial Bidding - One Project Having Several Items, Which Shall Be Awarded As Separate Contracts Per Item 19.5. Except For Bidders Submitting A Committed Line Of Credit From A Universal Or Commercial Bank In Lieu Of Its Nfcc Computation, All Bids Must Include The Nfcc Computation Pursuant To Section 23.4.1.4 Of The 2016 Revised Irr Of Ra No. 9184, Which Must Be Sufficient For The Total Of The Abcs For All The Lots Or Items Participated In By The Prospective Bidder. For Bidders Submitting The Committed Line Of Credit, It Must Be At Least Equal To Ten Percent (10%) Of The Abcs For All The Lots Or Items Participated In By The Prospective Bidder. 20. Post-qualification Within A Non-extendible Period Of Five (5) Calendar Days From Receipt By The Bidder Of The Notice From The Bac That It Submitted The Lowest Calculated Bid, The Bidder Shall Submit Its Latest Income And Business Tax Returns Filed And Paid Through The Bir Electronic Filing And Payment System (efps) And Other Appropriate Licenses And Permits Required By Law And Stated In The Bds. 21. Signing Of The Contract 21.1. The Documents Required In Section 37.2 Of The 2016 Revised Irr Of Ra No. 9184 Shall Form Part Of The Contract. Additional Contract Documents Are Indicated In The Bds. Section Iii. Bid Data Sheet Itb Clause 5.3 For This Purpose, Contracts Similar To The Project Shall Be: A. Refers To The Contracts To Be Bid Or The Object Of The Contract; B. Completed Within Three (3) Years Prior To The Deadline For The Submission And Receipt Of Bids. 7.1 Subcontracting Is Not Allowed. 12 The Price Of The Goods Shall Be Quoted Ddp Iloilo Provincial Hospital, Pototan Iloilo Or The Applicable International Commercial Terms (incoterms) For This Project. 14.1 The Bid Security Shall Be In The Form Of A Bid Securing Declaration, Or Any Of The Following Forms And Amounts: A. The Amount Of Not Less Than Two Percent (2%) Of Abc, If Bid Security Is In Cash, Cashier’s/manager’s Check, Bank Draft/guarantee Or Irrevocable Letter Of Credit; Or B. The Amount Of Not Less Than Five Percent (5%) Of Abc, If Bid Security Is In Surety Bond. 15 Bidders Shall Prepare An Original Of The First (eligibility And Technical) And Second (financial) Envelopes. In Addition, Bidders Shall Submit Separate Copies Of The First And Second Envelopes (copy 1, Copy 2) And Each Set Of Documents Must Clearly Indicate Whether The Same Is Original, Copy 1, Or Copy 2. In The Event Of Any Discrepancy Between The Original And The Copies, The Original Shall Prevail. 19.3 No Further Instructions. 20.2 For The Procurement Of Drugs And Medicines And Medical Equipment/supplies, The Bidder Shall Submit The Following: A. Certificate Of Product Registration From Food And Drug Administration (fda) For Easy Validation During The Post-qualification; B. Certificate If Good Manufacturing Practice From Fda, For Easy Validation During The Post-qualification; C. Batch Release Certificate From Fda, For Easy Validation During The Post-qualification; D. If The Supplier Is Not The Manufacturer, Certification From The Manufacturer That The Supplier Is An Authorized Distributor/ Dealer Of The Products / Items For Easy Validation During The Post-qualification; E. For The Procurement Of Regulated Drugs, The Applicable Type Of S-license: S-1, S-3 (retailer) S-4 (wholesaler) S-5c (manufacturer) S-5d (bulk Depot/storage) S-5e S-5i (importer); F. License To Operate (lto) Issued By Fda, If Applicable; G. After-sales Services/parts, If Applicable; H. Manpower Requirements, If Applicable. 21.2 No Further Instructions. Section Iv. General Conditions Of Contract 1. Scope Of Contract This Contract Shall Include All Such Items, Although Not Specifically Mentioned, That Can Be Reasonably Inferred As Being Required For Its Completion As If Such Items Were Expressly Mentioned Herein. All The Provisions Of Ra No. 9184 And Its 2016 Revised Irr, Including The Generic Procurement Manual, And Associated Issuances, Constitute The Primary Source For The Terms And Conditions Of The Contract, And Thus, Applicable In Contract Implementation. Herein Clauses Shall Serve As The Secondary Source For The Terms And Conditions Of The Contract. This Is Without Prejudice To Sections 74.1 And 74.2 Of The 2016 Revised Irr Of Ra No. 9184 Allowing The Gppb To Amend The Irr, Which Shall Be Applied To All Procurement Activities, The Advertisement, Posting, Or Invitation Of Which Were Issued After The Effectivity Of The Said Amendment. Additional Requirements For The Completion Of This Contract Shall Be Provided In The Special Conditions Of Contract (scc). 2. Advance Payment And Terms Of Payment 2.1. Advance Payment Of The Contract Amount Is Provided Under Annex “d” Of The Revised 2016 Irr Of Ra No. 9184. 2.2. The Procuring Entity Is Allowed To Determine The Terms Of Payment On The Partial Or Staggered Delivery Of The Goods Procured, Provided Such Partial Payment Shall Correspond To The Value Of The Goods Delivered And Accepted In Accordance With Prevailing Accounting And Auditing Rules And Regulations. The Terms Of Payment Are Indicated In The Scc. 3. Performance Security Within Ten (10) Calendar Days From Receipt Of The Notice Of Award By The Bidder From The Procuring Entity But In No Case Later Than Prior To The Signing Of The Contract By Both Parties, The Successful Bidder Shall Furnish The Performance Security In Any Of The Forms Prescribed In Section 39 Of The 2016 Revised Irr Of Ra No. 9184. 4. Inspection And Tests The Procuring Entity Or Its Representative Shall Have The Right To Inspect And/or To Test The Goods To Confirm Their Conformity To The Project Specifications At No Extra Cost To The Procuring Entity In Accordance With The Generic Procurement Manual. In Addition To Tests In The Scc, Section Iv (technical Specifications) Shall Specify What Inspections And/or Tests The Procuring Entity Requires, And Where They Are To Be Conducted. The Procuring Entity Shall Notify The Supplier In Writing, In A Timely Manner, Of The Identity Of Any Representatives Retained For These Purposes. All Reasonable Facilities And Assistance For The Inspection And Testing Of Goods, Including Access To Drawings And Production Data, Shall Be Provided By The Supplier To The Authorized Inspectors At No Charge To The Procuring Entity. 5. Warranty 6.1. In Order To Assure That Manufacturing Defects Shall Be Corrected By The Supplier, A Warranty Shall Be Required From The Supplier As Provided Under Section 62.1 Of The 2016 Revised Irr Of Ra No. 9184. 6.2. The Procuring Entity Shall Promptly Notify The Supplier In Writing Of Any Claims Arising Under This Warranty. Upon Receipt Of Such Notice, The Supplier Shall, Repair Or Replace The Defective Goods Or Parts Thereof Without Cost To The Procuring Entity, Pursuant To The Generic Procurement Manual. 6. Liability Of The Supplier The Supplier’s Liability Under This Contract Shall Be As Provided By The Laws Of The Republic Of The Philippines. If The Supplier Is A Joint Venture, All Partners To The Joint Venture Shall Be Jointly And Severally Liable To The Procuring Entity. Section V. Special Conditions Of Contract Gcc Clause 1 Delivery And Documents – For Purposes Of The Contract, “exw,” “fob,” “fca,” “cif,” “cip,” “ddp” And Other Trade Terms Used To Describe The Obligations Of The Parties Shall Have The Meanings Assigned To Them By The Current Edition Of Incoterms Published By The International Chamber Of Commerce, Paris. The Delivery Terms Of This Contract Shall Be As Follows: [for Goods Supplied From Within The Philippines, State:] “the Delivery Terms Applicable To This Contract Are Delivered To Error! Reference Source Not Found.. Risk And Title Will Pass From The Supplier To The Procuring Entity Upon Receipt And Final Acceptance Of The Goods At Their Final Destination.” Delivery Of The Goods Shall Be Made By The Supplier In Accordance With The Terms Specified In Section Vi (schedule Of Requirements). For Purposes Of This Clause The Procuring Entity’s Representative At The Project Site Is The Authorized Employee/official Of The Iloilo Provincial Government. Incidental Services – The Supplier Is Required To Provide All Of The Following Services, Including Additional Services, If Any, Specified In Section Vi. Schedule Of Requirements: A. Performance Or Supervision Of On-site Assembly And/or Start-up Of The Supplied Goods; B. Furnishing Of Tools Required For Assembly And/or Maintenance Of The Supplied Goods; C. Furnishing Of A Detailed Operations And Maintenance Manual For Each Appropriate Unit Of The Supplied Goods; The Contract Price For The Goods Shall Include The Prices Charged By The Supplier For Incidental Services And Shall Not Exceed The Prevailing Rates Charged To Other Parties By The Supplier For Similar Services. Packaging – The Supplier Shall Provide Such Packaging Of The Goods As Is Required To Prevent Their Damage Or Deterioration During Transit To Their Final Destination, As Indicated In This Contract. The Packaging Shall Be Sufficient To Withstand, Without Limitation, Rough Handling During Transit And Exposure To Extreme Temperatures, Salt And Precipitation During Transit, And Open Storage. Packaging Case Size And Weights Shall Take Into Consideration, Where Appropriate, The Remoteness Of The Goods’ Final Destination And The Absence Of Heavy Handling Facilities At All Points In Transit. The Packaging, Marking, And Documentation Within And Outside The Packages Shall Comply Strictly With Such Special Requirements As Shall Be Expressly Provided For In The Contract, Including Additional Requirements, If Any, Specified Below, And In Any Subsequent Instructions Ordered By The Procuring Entity. The Outer Packaging Must Be Clearly Marked On At Least Four (4) Sides As Follows: Name Of The Procuring Entity Name Of The Supplier Contract Description Final Destination Gross Weight Any Special Lifting Instructions Any Special Handling Instructions A Packaging List Identifying The Contents And Quantities Of The Package Is To Be Placed On An Accessible Point Of The Outer Packaging If Practical. If Not Practical The Packaging List Is To Be Placed Inside The Outer Packaging But Outside The Secondary Packaging. Transportation – Where The Supplier Is Required Under Contract To Deliver The Goods Cif, Cip, Or Ddp, Transport Of The Goods To The Port Of Destination Or Such Other Named Place Of Destination In The Philippines, As Shall Be Specified In This Contract, Shall Be Arranged And Paid For By The Supplier, And The Cost Thereof Shall Be Included In The Contract Price. Where The Supplier Is Required Under This Contract To Transport The Goods To A Specified Place Of Destination Within The Philippines, Defined As The Project Site, Transport To Such Place Of Destination In The Philippines, Including Insurance And Storage, As Shall Be Specified In This Contract, Shall Be Arranged By The Supplier, And Related Costs Shall Be Included In The Contract Price. Where The Supplier Is Required Under Contract To Deliver The Goods Cif, Cip Or Ddp, Goods Are To Be Transported On Carriers Of Philippine Registry. In The Event That No Carrier Of Philippine Registry Is Available, Goods May Be Shipped By A Carrier Which Is Not Of Philippine Registry Provided That The Supplier Obtains And Presents To The Procuring Entity Certification To This Effect From The Nearest Philippine Consulate To The Port Of Dispatch. In The Event That Carriers Of Philippine Registry Are Available But Their Schedule Delays The Supplier In Its Performance Of This Contract The Period From When The Goods Were First Ready For Shipment And The Actual Date Of Shipment The Period Of Delay Will Be Considered Force Majeure. The Procuring Entity Accepts No Liability For The Damage Of Goods During Transit Other Than Those Prescribed By Incoterms For Ddp Deliveries. In The Case Of Goods Supplied From Within The Philippines Or Supplied By Domestic Suppliers Risk And Title Will Not Be Deemed To Have Passed To The Procuring Entity Until Their Receipt And Final Acceptance At The Final Destination. 2.2 Partial Payment Is Not Allowed. 4 The Inspections And Tests That Will Be Conducted Are Through Physical Inspection. Section Vi. Schedule Of Requirements The Delivery Schedule Expressed As Weeks/months Stipulates Hereafter A Delivery Date Which Is The Date Of Delivery To The Project Site. Item Number Description Quantity Total Delivered, Weeks/months 1 Glucose Reagent 400ml 4 4 2 Cholesterol Reagent 400ml 4 4 3 Triglycerides Reagent 400ml 2 2 4 Uric Acid Reagent 400ml 3 3 5 Urea/bun Reagent 300ml 3 3 6 Hdl Cholesterol Reagent 250ml 1 1 7 Normal Control 5x5ml 5 5 8 Pathologic Control 5x5ml 5 5 9 Sgpt Reagent 500ml 3 3 10 Typing Sera (anti-a, Anti-b) 10cc 100 100 11 Anti D 10cc (rh Typing) 70 70 12 Antibody Enhancement (liss) 10cc 30 30 13 Anti Human Globulin 10cc 30 30 14 Dengue Test Kit (duo, Igg,igm, Ns1) 25's 10 10 15 Crp Reagent 150's 15 15 16 Aso Titer Reagent 100's 2 2 17 Troponin I Cassette 40's 10 10 18 Thermal Paper 57mmx10m 200 200 19 Wooden Applicator Sticks 1000's 20 20 20 Paper Towel 176pulls 100 100 21 Distilled Water 10ltrs 30 30 22 H. Pylori Antibody 25's 2 2 23 Glucose Tolerance Test Beverage (75 G. Dextrose) 200 200 24 Hema Stain (500ml) 5 5 25 Urine Strips 4 Parameter 100 100 26 0.5ml Microtainer Lavender Top 100's 100 100 27 5ml Red Top Plain Tubes Glass 100s 50 50 28 10ml Red Top Plain Tubes Glass 100's 10 10 29 Sedi Rate Esr Pipette Westergreen 200’s 2 2 30 Microlancets 200's G23 20 20 31 Microhematocrit Tubes, Heparinized Red Tip 1000's 3 3 32 Yellow Pipettor Tips 1000's 100 100 33 Blue Pipettor Tips 500's 30 30 34 G3+ Cartridge 25's For Istat Machine 24 24 35 Tri Control Level I (10x1.7ml) For Istat Machine 1 1 36 Tri Control Level Ii (10x1.7ml) For Istat Machine 3 3 37 Tri Control Level Ill (10x1.7ml) For Istat Machine 1 1 38 Leptospirosis 30's Igg/igm 3 3 39 Hbsag Strips 50's Igg/igm 6 6 40 Salmonella Typhi 30's Igg/igm 5 5 41 Heparinized Syringe 3cc 400 400 42 Black Top Tubes 2.4ml Citrated Glass 100's 6 6 43 Yellow Tap Tubes (gel Separator) 4ml Glass 10 10 44 Creatinine Reagent (jaffe, Kinetic) 400ml 8 8 _______________________ Signature Over Printed Name Section Vii. Technical Specifications Bid No.: Iph-24-1467-b Item Specification Statement Of Compliance [bidders Must State Here Either “comply” Or “not Comply” Against Each Of The Individual Parameters Of Each Specification Stating The Corresponding Performance Parameter Of The Equipment Offered. Statements Of “comply” Or “not Comply” Must Be Supported By Evidence In A Bidders Bid And Cross-referenced To That Evidence. Evidence Shall Be In The Form Of Manufacturer’s Un-amended Sales Literature, Unconditional Statements Of Specification And Compliance Issued By The Manufacturer, Samples, Independent Test Data Etc., As Appropriate. A Statement That Is Not Supported By Evidence Or Is Subsequently Found To Be Contradicted By The Evidence Presented Will Render The Bid Under Evaluation Liable For Rejection. A Statement Either In The Bidder's Statement Of Compliance Or The Supporting Evidence That Is Found To Be False Either During Bid Evaluation, Post-qualification Or The Execution Of The Contract May Be Regarded As Fraudulent And Render The Bidder Or Supplier Liable For Prosecution Subject To The Applicable Laws And Issuances.] 1 Glucose Reagent 400ml 2 Cholesterol Reagent 400ml 3 Triglycerides Reagent 400ml 4 Uric Acid Reagent 400ml 5 Urea/bun Reagent 300ml 6 Hdl Cholesterol Reagent 250ml 7 Normal Control 5x5ml 8 Pathologic Control 5x5ml 9 Sgpt Reagent 500ml 10 Typing Sera (anti-a, Anti-b) 10cc 11 Anti D 10cc (rh Typing) 12 Antibody Enhancement (liss) 10cc 13 Anti Human Globulin 10cc 14 Dengue Test Kit (duo, Igg,igm, Ns1) 25's 15 Crp Reagent 150's 16 Aso Titer Reagent 100's 17 Troponin I Cassette 40's 18 Thermal Paper 57mmx10m 19 Wooden Applicator Sticks 1000's 20 Paper Towel 176pulls 21 Distilled Water 10ltrs 22 H. Pylori Antibody 25's 23 Glucose Tolerance Test Beverage (75 G. Dextrose) 24 Hema Stain (500ml) 25 Urine Strips 4 Parameter 26 0.5ml Microtainer Lavender Top 100's 27 5ml Red Top Plain Tubes Glass 100s 28 10ml Red Top Plain Tubes Glass 100's 29 Sedi Rate Esr Pipette Westergreen 200’s 30 Microlancets 200's G23 31 Microhematocrit Tubes, Heparinized Red Tip 1000's 32 Yellow Pipettor Tips 1000's 33 Blue Pipettor Tips 500's 34 G3+ Cartridge 25's For Istat Machine 35 Tri Control Level I (10x1.7ml) For Istat Machine 36 Tri Control Level Ii (10x1.7ml) For Istat Machine 37 Tri Control Level Ill (10x1.7ml) For Istat Machine 38 Leptospirosis 30's Igg/igm 39 Hbsag Strips 50's Igg/igm 40 Salmonella Typhi 30's Igg/igm 41 Heparinized Syringe 3cc 42 Black Top Tubes 2.4ml Citrated Glass 100's 43 Yellow Tap Tubes (gel Separator) 4ml Glass 44 Creatinine Reagent (jaffe, Kinetic) 400ml _______________________ Signature Over Printed Name Section Viii. Checklist Of Technical And Financial Documents I. Technical Component Envelope Class “a” Documents Legal Documents ⬜ (a) Valid Philgeps Registration Certificate (platinum Membership) (all Pages);or ⬜ (b) Registration Certificate From Securities And Exchange Commission (sec), Department Of Trade And Industry (dti) For Sole Proprietorship, Or Cooperative Development Authority (cda) For Cooperatives Or Its Equivalent Document, And ⬜ (c) Mayor’s Or Business Permit Issued By The City Or Municipality Where The Principal Place Of Business Of The Prospective Bidder Is Located, Or The Equivalent Document For Exclusive Economic Zones Or Areas; And ⬜ (d) Tax Clearance Per E.o. No. 398, S. 2005, As Finally Reviewed And Approved By The Bureau Of Internal Revenue (bir). Technical Documents ⬜ (e) Statement Of The Prospective Bidder Of All Its Ongoing Government And Private Contracts, Including Contracts Awarded But Not Yet Started, If Any, Whether Similar Or Not Similar In Nature And Complexity To The Contract To Be Bid; And ⬜ (f) Statement Of The Bidder’s Single Largest Completed Contract (slcc) Similar To The Contract To Be Bid, Except Under Conditions Provided For In Sections 23.4.1.3 And 23.4.2.4 Of The 2016 Revised Irr Of Ra No. 9184, Within The Relevant Period As Provided In The Bidding Documents; And ⬜ (g) Original Copy Of Bid Security. If In The Form Of A Surety Bond, Submit Also A Certification Issued By The Insurance Commission; Or Original Copy Of Notarized Bid Securing Declaration; And ⬜ (h) Conformity With The Technical Specifications, Which May Include Production/delivery Schedule, Manpower Requirements, And/or After-sales/parts, If Applicable; And ⬜ (i) Original Duly Signed Omnibus Sworn Statement (oss); And If Applicable, Original Notarized Secretary’s Certificate In Case Of A Corporation, Partnership, Or Cooperative; Or Original Special Power Of Attorney Of All Members Of The Joint Venture Giving Full Power And Authority To Its Officer To Sign The Oss And Do Acts To Represent The Bidder. Financial Documents ⬜ (j) The Supplier’s Audited Financial Statements, Showing, Among Others, The Supplier’s Total And Current Assets And Liabilities, Stamped “received” By The Bir Or Its Duly Accredited And Authorized Institutions, For The Preceding Calendar Year Which Should Not Be Earlier Than Two (2) Years From The Date Of Bid Submission; And ⬜ (k) The Prospective Bidder’s Computation Of Net Financial Contracting Capacity (nfcc); Or A Committed Line Of Credit From A Universal Or Commercial Bank In Lieu Of Its Nfcc Computation. Class “b” Documents ⬜ (l) If Applicable, A Duly Signed Joint Venture Agreement (jva) In Case The Joint Venture Is Already In Existence; Or Duly Notarized Statements From All The Potential Joint Venture Partners Stating That They Will Enter Into And Abide By The Provisions Of The Jva In The Instance That The Bid Is Successful. Ii. Financial Component Envelope ⬜ (m) Original Of Duly Signed And Accomplished Financial Bid Form; And ⬜ (n) Original Of Duly Signed And Accomplished Price Schedule(s). Other Documentary Requirements Under Ra No. 9184 (as Applicable) ⬜ (o) [for Foreign Bidders Claiming By Reason Of Their Country’s Extension Of Reciprocal Rights To Filipinos] Certification From The Relevant Government Office Of Their Country Stating That Filipinos Are Allowed To Participate In Government Procurement Activities For The Same Item Or Product. ⬜ (p) Certification From The Dti If The Bidder Claims Preference As A Domestic Bidder Or Domestic Entity.
Closing Date11 Dec 2024
Tender AmountPHP 1.5 Million (USD 27 K)
Province Of Iloilo Tender
Others
Philippines
Details: Description Bids And Awards Committee Iloilo Provincial Government Procurement Of Housekeeping Supplies Bid No. Sjh-24-1608-b Philippine Bidding Documents Sixth Edition July 2020 Table Of Contents Section I. Invitation To Bid……………………………………………………..3 Section Ii. Instructions To Bidders………………………………………..…...5 1. Scope Of Bid ………………………………………………………………………. 5 2. Funding Information………………………………………………………………. 5 3. Bidding Requirements ……………………………………………………………. 5 4. Corrupt, Fraudulent, Collusive, And Coercive Practices 5 5. Eligible Bidders…………………………………………………………………… 5 6. Origin Of Goods ………………………………………………………………….. 6 7. Subcontracts ……………………………………………………………………… 6 8. Pre-bid Conference ………………………………………………………………. 7 9. Clarification And Amendment Of Bidding Documents …………………………… 7 10. Documents Comprising The Bid: Eligibility And Technical Components …………. 7 11. Documents Comprising The Bid: Financial Component …………………………... 7 12. Bid Prices …………………………………………………………………………. 8 13. Bid And Payment Currencies ……………………………………………………… 8 14. Bid Security ………………………………………………………………………. 8 15. Sealing And Marking Of Bids ……………………………………………………… 9 16. Deadline For Submission Of Bids …………………………………………………. 9 17. Opening And Preliminary Examination Of Bids ………………………………….. 9 18. Domestic Preference ……………………………………………………………… 9 19. Detailed Evaluation And Comparison Of Bids ……………………………………. 9 20. Post-qualification ………………………………………………………………… 10 21. Signing Of The Contract …………………………………………………………… 10 Section Iii. Bid Data Sheet …………………………………………………..11 Section Iv. General Conditions Of Contract……………………...………..12 1. Scope Of Contract ………………………………………………………………… 12 2. Advance Payment And Terms Of Payment ……………………………………….. 12 3. Performance Security ……………………………………………………………. 12 4. Inspection And Tests ……………………………………………………………… 12 5. Warranty …………………………………………………………………………. 13 6. Liability Of The Supplier ………………………………………………………….. 13 Section V. Special Conditions Of Contract ………………………………….14 Section Vi. Schedule Of Requirements ……………………………………....16 Section Vii. Technical Specifications ……………………………………17 Section Viii. Checklist Of Technical And Financial Documents …………..22 Section I. Invitation To Bid Purchase Of Housekeeping Supplies Bid No. Sjh-24-1608-b 1. The Iloilo Provincial Government Through The Mooe Sb#1, 2024 Gen. Fund. Intends To Apply The Sum Of One Million Five Hundred Thousand Pesos (₱1,500,000.00) Being The Abc To Payments Under The Contract For The Purchase Of Housekeeping Supplies. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The Iloilo Provincial Government Now Invites Bids For The Above Procurement Project.delivery Of The Goods Is Required By 14 Days Upon Receipt Of The Notice To Proceed (ntp). Bidders Should Have Completed, Within Three (3) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From The Bids And Awards Committee Secretariat Of The Iloilo Provincial Government And Inspect The Bidding Documents At The Address Given Below During 8:00 A.m. To 5:00 P.m. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On November 13, 2024 From The Given Address And Website(s) Below And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of Five Thousand Pesos (₱ 5,000.00). The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees In Person. 6. The Iloilo Provincial Government Will Hold A Pre-bid Conference On November 20, 2024 At The 5th Floor Bids And Awards Committee Secretariat Office, Iloilo Provincial Capitol, Iloilo City And/or Through Video Conferencing Or Webcasting, Upon Request At Least Three (3) Days Before The Pre-bid Conference, Via Zoom Or Other Videoconferencing Portals, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Bids And Awards Committee Secretariat Office, 5th Floor, Iloilo Provincial Capitol On Or Before December 4, 2024 At 9:00 A.m. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On December 4 At 9:01 A.m.at The Bids And Awards Committee Secretariat Office, 5th Floor, Iloilo Provincial Capitol. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. A. The Participating Bidder/supplier Or Its Authorized Representative Must Indicate In Any Of The Eligibility Documents, An Email Address Or A Working Fax Number. The Absence Of Which Shall Be A Ground For Disqualification. Notice To The Bidder/supplier Through The Use Of Either Of These Means (email/fax) Is Considered Sufficient Notice. The Date Of Filing Of Reconsideration And All Communications With The Bac Shall Be Its (bac) Date Of Receipt. B. The Bidder(s)/awardee(s) Or Its Authorized Representative Must Conform To The Notice Of Award Within Three (3) Calendar Days From Receipt Of Such Notice And The Winning Bidder Shall Post The Required Performance Security And Enter Into Contract With The Procuring Entity Within Ten (10) Calendar Days From Receipt By The Winning Bidder Of The Notice Of Award In Accordance With Section 37.2.1 Of The Revised Irr Of R.a. No. 9184. C. The Bidder/supplier Must Have No Pending Unaccepted Notice To Proceed Three (3) Days From The Date Of Acceptance And Signing Of The Purchase Order. Otherwise, It Shall Be A Ground For Disqualification And The Bidder Will Be Rated "failed" During The Preliminary Examination Of Bids And/or Its Bid Shall Be Declared As "non-responsive" During Post-qualification. D. The Bidder/supplier Must Have No Notice Of Award Pending Its Conformity Three (3) Days From The Date Of Its Receipt Of The Notice Of Award. Otherwise, It Shall Be Aground For Disqualification And The Bidder Will Be Rated "failed" During The Preliminary Examination Of Bids And/or Its Bid Shall Be Declared As "non-responsive" During Post-qualification. E. The Bidder/supplier Shall Submit A List Of All Its Ongoing And Completed Projects With The Iloilo Provincial Government Indicating The Delivery Periods And Accomplishments Of Such Projects. F. The Bidder/supplier At The Time Of The Bidding Must Have No Pending Unposted Performance Or Warranty Security, As The Case May Be, Beyond The Period Allowed In The Notice Of Award. Otherwise, It Shall Be A Ground For Disqualification And The Bidder Will Be Rated "failed" During The Preliminary Examination Of Bids And/or Its Bid Shall Be Declared As "non-responsive" During Post-qualification. G. When An Occurrence Of A Tie Among Bidders Takes Place, I.e., Two Or More Of The Bidders Are Determined And Declared As The Lowest Calculated And Responsive Bidder (lcrb), The Winning Bidder Shall Be Determined By Draw Lots Upon Notice To The Bidders Concerned And/or Their Authorized Representatives In Accordance With The Relevant Circulars Issued By The Government Procurement Policy Board (gppb). 11. The Iloilo Provincial Governmentreserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 12. For Further Information, Please Refer To: Atty. Raemman M. Lagrada Bac Secretariat Head 5th Floor, Bids And Awards Committee Iloilo Provincial Capitol Email Address: Ipg_bacs@yahoo.com Website: Iloilo.gov.ph Telephone Number: (033) 336-0736 13. You May Visit The Following Websites For Downloading Of Bidding Documents: Ipg.gov.ph And/or Philgeps.com November 5, 2024 Atty. Dennis T. Ventilacion Chairperson, Bids And Awards Committee Section Ii. Instructions To Bidders 1. Scope Of Bid The Procuring Entity, Iloilo Provincial Governmentwishes To Receive Bids For The Purchase Of Housekeeping Supplies With Bid No. Sjh-24-1608-b. The Procurement Project (referred To Herein As “project”) Is Composed Of Sixty Three (63) Item's, The Details Of Which Are Described In Section Vii (technical Specifications). 2. Funding Information 2.1. The Gop Through The Source Of Funding As Indicated Below For 2024 In The Amount Of One Million Five Hundred Thousand Pesos(₱1,500,000.00). 2.2. The Source Of Funding Is: A. Lgus, The Annual Or Supplemental Budget, As Approved By The Sanggunian. 3. Bidding Requirements The Bidding For The Project Shall Be Governed By All The Provisions Of Ra No. 9184 And Its 2016 Revised Irr, Including Its Generic Procurement Manuals And Associated Policies, Rules And Regulations As The Primary Source Thereof, While The Herein Clauses Shall Serve As The Secondary Source Thereof. Any Amendments Made To The Irr And Other Gppb Issuances Shall Be Applicable Only To The Ongoing Posting, Advertisement, Orib By The Bac Through The Issuance Of A Supplemental Or Bid Bulletin. The Bidder, By The Act Of Submitting Its Bid, Shall Be Deemed To Have Verified And Accepted The General Requirements Of This Project, Including Other Factors That May Affect The Cost, Duration And Execution Or Implementation Of The Contract, Project, Or Work And Examine All Instructions, Forms, Terms, And Project Requirements In The Bidding Documents. 4. Corrupt, Fraudulent, Collusive, And Coercive Practices The Procuring Entity, As Well As The Bidders And Suppliers, Shall Observe The Highest Standard Of Ethics During The Procurement And Execution Of The Contract. They Or Through An Agent Shall Not Engage In Corrupt, Fraudulent, Collusive, Coercive, And Obstructive Practices Defined Under Annex “i” Of The 2016 Revised Irr Of Ra No. 9184 Or Other Integrity Violations In Competing For The Project. 5. Eligible Bidders 5.1. Only Bids Of Bidders Found To Be Legally, Technically, And Financially Capable Will Be Evaluated. 5.2. A. Foreign Ownership Exceeding Those Allowed Under The Rules May Participate Pursuant To: I. When A Treaty Or International Or Executive Agreement As Provided In Section 4 Of The Ra No. 9184 And Its 2016 Revised Irr Allow Foreign Bidders To Participate; Ii. Citizens, Corporations, Or Associations Of A Country, Included In The List Issued By The Gppb, The Laws Or Regulations Of Which Grant Reciprocal Rights Or Privileges To Citizens, Corporations, Or Associations Of The Philippines; Iii. When The Goods Sought To Be Procured Are Not Available From Local Suppliers; Or Iv. When There Is A Need To Prevent Situations That Defeat Competition Or Restrain Trade. 5.3. Pursuant To Section 23.4.1.3 Of The 2016 Revised Irr Of Ra No.9184, The Bidder Shall Have An Slcc That Is At Least One (1) Contract Similar To The Project The Value Of Which, Adjusted To Current Prices Using The Psa’s Cpi, Must Be At Least Equivalent To: A. For The Procurement Of Non-expendable Supplies And Services: The Bidder Must Have Completed A Single Contract That Is Similar To This Project, Equivalent To At Least Fifty Percent (50%) Of The Abc. B. For The Procurement Of Expendable Supplies: The Bidder Must Have Completed A Single Contract That Is Similar To This Project, Equivalent To At Least Twenty-five Percent (25%) Of The Abc. C. For Procurement Where The Procuring Entity Has Determined, After The Conduct Of Market Research, That Imposition Of Either (a) Or (b) Will Likely Result To Failure Of Bidding Or Monopoly That Will Defeat The Purpose Of Public Bidding: The Bidder Should Comply With The Following Requirements: [select Either Failure Or Monopoly Of Bidding Based On Market Research Conducted] I. Completed At Least Two (2) Similar Contracts, The Aggregate Amount Of Which Should Be Equivalent To At Least Fifty Percent (50%) In The Case Of Non-expendable Supplies And Services Or Twenty-five Percent (25%) In The Case Of Expendable Supplies] Of The Abc For This Project; And Ii. The Largest Of These Similar Contracts Must Be Equivalent To At Least Half Of The Percentage Of The Abc As Required Above. 5.4. The Bidders Shall Comply With The Eligibility Criteria Under Section 23.4.1 Of The 2016 Irr Of Ra No. 9184. 6. Origin Of Goods There Is No Restriction On The Origin Of Goods Other Than Those Prohibited By A Decision Of The Un Security Council Taken Under Chapter Vii Of The Charter Of The Un, Subject To Domestic Preference Requirements Under Itb Clause 18. 7. Subcontracts 7.1. The Bidder May Subcontract Portions Of The Project To The Extent Allowed By The Procuring Entity As Stated Herein, But In No Case More Than Twenty Percent (20%) Of The Project. The Procuring Entity Has Prescribed That: Subcontracting Is Not Allowed. 8. Pre-bid Conference The Procuring Entity Will Hold A Pre-bid Conference For This Project On The Specified Date And Time And Either At Its Physical Address As Indicated In Paragraph 6 Of The Ib. 9. Clarification And Amendment Of Bidding Documents Prospective Bidders May Request For Clarification On And/or Interpretation Of Any Part Of The Bidding Documents. Such Requests Must Be In Writing And Received By The Procuring Entity, Either At Its Given Address Or Through Electronic Mail Indicated In The Ib, At Least Ten (10) Calendar Days Before The Deadline Set For The Submission And Receipt Of Bids. 10. Documents Comprising The Bid: Eligibility And Technical Components 10.1. The First Envelope Shall Contain The Eligibility And Technical Documents Of The Bid As Specified In Section Viii (checklist Of Technical And Financial Documents). 10.2. The Bidder’s Slcc As Indicated In Itb Clause5.3 Should Have Been Completed Within Three (3) Yearsprior To The Deadline For The Submission And Receipt Of Bids. 10.3. If The Eligibility Requirements Or Statements, The Bids, And All Other Documents For Submission To The Bac Are In Foreign Language Other Than English, It Must Be Accompanied By A Translation In English, Which Shall Be Authenticated By The Appropriate Philippine Foreign Service Establishment, Post, Or The Equivalent Office Having Jurisdiction Over The Foreign Bidder’s Affairs In The Philippines. Similar To The Required Authentication Above, For Contracting Parties To The Apostille Convention, Only The Translated Documents Shall Be Authenticated Through An Apostille Pursuant To Gppb Resolution No. 13-2019 Dated 23 May 2019. The English Translation Shall Govern, For Purposes Of Interpretation Of The Bid. 11. Documents Comprising The Bid: Financial Component 11.1. The Second Bid Envelope Shall Contain The Financial Documents For The Bid As Specified In Section Viii (checklist Of Technical And Financial Documents). 11.2. If The Bidder Claims Preference As A Domestic Bidder Or Domestic Entity, A Certification Issued By Dti Shall Be Provided By The Bidder In Accordance With Section 43.1.3 Of The 2016 Revised Irr Of Ra No. 9184. 11.3. Any Bid Exceeding The Abc Indicated In Paragraph 1 Of The Ib Shall Not Be Accepted. 11.4. For Foreign-funded Procurement, A Ceiling May Be Applied To Bid Prices Provided The Conditions Are Met Under Section 31.2 Of The 2016 Revised Irr Of Ra No. 9184. 12. Bid Prices 12.1. Prices Indicated On The Price Schedule Shall Be Entered Separately In The Following Manner: A. For Goods Offered From Within The Procuring Entity’s Country: I. The Price Of The Goods Quoted Exw (ex-works, Ex-factory, Ex-warehouse, Ex-showroom, Or Off-the-shelf, As Applicable); Ii. The Cost Of All Customs Duties And Sales And Other Taxes Already Paid Or Payable; Iii. The Cost Of Transportation, Insurance, And Other Costs Incidental To Delivery Of The Goods To Their Final Destination; And Iv. The Price Of Other (incidental) Services, If Any, Listed In E. B. For Goods Offered From Abroad: I. Unless Otherwise Stated In The Bds, The Price Of The Goods Shall Be Quoted Delivered Duty Paid (ddp) With The Place Of Destination In The Philippines As Specified In The Bds. In Quoting The Price, The Bidder Shall Be Free To Use Transportation Through Carriers Registered In Any Eligible Country. Similarly, The Bidder May Obtain Insurance Services From Any Eligible Source Country. Ii. The Price Of Other (incidental) Services, If Any, As Listed In Section Vii (technical Specifications). 13. Bid And Payment Currencies 13.1. For Goods That The Bidder Will Supply From Outside The Philippines, The Bid Prices May Be Quoted In The Local Currency Or Tradeable Currency Accepted By The Bsp At The Discretion Of The Bidder. However, For Purposes Of Bid Evaluation, Bids Denominated In Foreign Currencies, Shall Be Converted To Philippine Currency Based On The Exchange Rate As Published In The Bsp Reference Rate Bulletin On The Day Of The Bid Opening. 13.2. Payment Of The Contract Price Shall Be Made In:philippine Pesos. 14. Bid Security 14.1. The Bidder Shall Submit A Bid Securing Declaration Or Any Form Of Bid Security In The Amount Indicated In The Bds, Which Shall Be Not Less Than The Percentage Of The Abc In Accordance With The Schedule In The Bds. 14.2. The Bid And Bid Security Shall Be Valid Until One Hundred Twenty (120) Days. Any Bid Not Accompanied By An Acceptable Bid Security Shall Be Rejected By The Procuring Entity As Non-responsive. 15. Sealing And Marking Of Bids Each Bidder Shall Submit One Copy Of The First And Second Components Of Its Bid. The Procuring Entity May Request Additional Hard Copies And/or Electronic Copies Of The Bid. However, Failure Of The Bidders To Comply With The Said Request Shall Not Be A Ground For Disqualification. 16. Deadline For Submission Of Bids 16.1. The Bidders Shall Submit On The Specified Date And Time At Its Physical Address As Indicated In Paragraph 7 Of The Ib. 17. Opening And Preliminary Examination Of Bids 17.1. The Bac Shall Open The Bids In Public At The Time, On The Date, And At The Place Specified In Paragraph 9 Of The Ib. The Bidders’ Representatives Who Are Present Shall Sign A Register Evidencing Their Attendance. In Case Videoconferencing, Webcasting Or Other Similar Technologies Will Be Used, Attendance Of Participants Shall Likewise Be Recorded By The Bac Secretariat. In Case The Bids Cannot Be Opened As Scheduled Due To Justifiable Reasons, The Rescheduling Requirements Under Section 29 Of The 2016 Revised Irr Of Ra No. 9184 Shall Prevail. 17.2. The Preliminary Examination Of Bids Shall Be Governed By Section 30 Of The 2016 Revised Irr Of Ra No. 9184. 18. Domestic Preference 18.1. The Procuring Entity Will Grant A Margin Of Preference For The Purpose Of Comparison Of Bids In Accordance With Section 43.1.2 Of The 2016 Revised Irr Of Ra No. 9184. 19. Detailed Evaluation And Comparison Of Bids 19.1. The Procuring Bac Shall Immediately Conduct A Detailed Evaluation Of All Bids Rated “passed,” Using Non-discretionary Pass/fail Criteria. The Bac Shall Consider The Conditions In The Evaluation Of Bids Under Section 32.2 Of The 2016 Revised Irr Of Ra No. 9184. 19.2. If The Project Allows Partial Bids, Bidders May Submit A Proposal On Any Of The Lots Or Items, And Evaluation Will Be Undertaken On A Per Lot Or Item Basis, As The Case Maybe. In This Case, The Bid Security As Required By Itb Clause 15 Shall Be Submitted For Each Lot Or Item Separately. 19.3. The Descriptions Of The Lots Or Items Shall Be Indicated In Section Vii (technical Specifications), Although The Abcs Of These Lots Or Items Are Indicated In The Bds For Purposes Of The Nfcc Computation Pursuant To Section 23.4.2.6 Of The 2016 Revised Irr Of Ra No. 9184. The Nfcc Must Be Sufficient For The Total Of The Abcs For All The Lots Or Items Participated In By The Prospective Bidder. 19.4. The Project Shall Be Awarded As Follows: Complete Bid - One Project Having Several Items That Shall Be Awarded As One Contract In Case Of Complete Bid. Line Bidding/partial Bidding - One Project Having Several Items, Which Shall Be Awarded As Separate Contracts Per Item 19.5. Except For Bidders Submitting A Committed Line Of Credit From A Universal Or Commercial Bank In Lieu Of Its Nfcc Computation, All Bids Must Include The Nfcc Computation Pursuant To Section 23.4.1.4 Of The 2016 Revised Irr Of Ra No. 9184, Which Must Be Sufficient For The Total Of The Abcs For All The Lots Or Items Participated In By The Prospective Bidder. For Bidders Submitting The Committed Line Of Credit, It Must Be At Least Equal To Ten Percent (10%) Of The Abcs For All The Lots Or Items Participated In By The Prospective Bidder. 20. Post-qualification Within A Non-extendible Period Of Five (5) Calendar Days From Receipt By The Bidder Of The Notice From The Bac That It Submitted The Lowest Calculated Bid, The Bidder Shall Submit Its Latest Income And Business Tax Returns Filed And Paid Through The Bir Electronic Filing And Payment System (efps) And Other Appropriate Licenses And Permits Required By Law And Stated In The Bds. 21. Signing Of The Contract 21.1. The Documents Required In Section 37.2 Of The 2016 Revised Irr Of Ra No. 9184 Shall Form Part Of The Contract. Additional Contract Documents Are Indicated In The Bds. Section Iii. Bid Data Sheet Itb Clause 5.3 For This Purpose, Contracts Similar To The Project Shall Be: A. Refers To The Contracts To Be Bid Or The Object Of The Contract; B. Completed Within Three (3) Years Prior To The Deadline For The Submission And Receipt Of Bids. 7.1 Subcontracting Is Not Allowed. 12 The Price Of The Goods Shall Be Quoted Ddp[san Joaquin Mother And Child Hospital, San Joaquin, Iloilo]or The Applicable International Commercial Terms (incoterms) For This Project. 14.1 The Bid Security Shall Be In The Form Of A Bid Securing Declaration, Or Any Of The Following Forms And Amounts: A. The Amount Of Not Less Than Two Percent (2%) Of Abc, If Bid Security Is In Cash, Cashier’s/manager’s Check, Bank Draft/guarantee Or Irrevocable Letter Of Credit; Or B. The Amount Of Not Less Than Five Percent (5%) Of Abc, If Bid Security Is In Surety Bond. 15 Bidders Shall Prepare An Original Of The First (eligibility And Technical) And Second (financial) Envelopes. In Addition, Bidders Shall Submit Separate Copies Of The First And Second Envelopes (copy 1, Copy 2) And Each Set Of Documents Must Clearly Indicate Whether The Same Is Original, Copy 1, Or Copy 2. In The Event Of Any Discrepancy Between The Original And The Copies, The Original Shall Prevail. 19.3 No Further Instructions. 20.2 For The Procurement Of Drugs And Medicines And Medical Equipment/supplies, The Bidder Shall Submit The Following: A. Certificate Of Product Registration From Food And Drug Administration (fda) For Easy Validation During The Post-qualification; B. Certificate If Good Manufacturing Practice From Fda, For Easy Validation During The Post-qualification; C. Batch Release Certificate From Fda, For Easy Validation During The Post-qualification; D. If The Supplier Is Not The Manufacturer, Certification From The Manufacturer That The Supplier Is An Authorized Distributor/ Dealer Of The Products / Items For Easy Validation During The Post-qualification; E. For The Procurement Of Regulated Drugs, The Applicable Type Of S-license: S-1, S-3 (retailer) S-4 (wholesaler) S-5c (manufacturer) S-5d (bulk Depot/storage) S-5e S-5i (importer); F. License To Operate (lto) Issued By Fda, If Applicable; G. After-sales Services/parts, If Applicable; H. Manpower Requirements, If Applicable. 21.2 No Further Instructions. Section Iv. General Conditions Of Contract 1. Scope Of Contract This Contract Shall Include All Such Items, Although Not Specifically Mentioned, That Can Be Reasonably Inferred As Being Required For Its Completion As If Such Items Were Expressly Mentioned Herein. All The Provisions Of Ra No. 9184 And Its 2016 Revised Irr, Including The Generic Procurement Manual, And Associated Issuances, Constitute The Primary Source For The Terms And Conditions Of The Contract, And Thus, Applicable In Contract Implementation. Herein Clauses Shall Serve As The Secondary Source For The Terms And Conditions Of The Contract. This Is Without Prejudice To Sections 74.1 And 74.2 Of The 2016 Revised Irr Of Ra No. 9184 Allowing The Gppb To Amend The Irr, Which Shall Be Applied To All Procurement Activities, The Advertisement, Posting, Or Invitation Of Which Were Issued After The Effectivity Of The Said Amendment. Additional Requirements For The Completion Of This Contract Shall Be Provided In The Special Conditions Of Contract (scc). 2. Advance Payment And Terms Of Payment 2.1. Advance Payment Of The Contract Amount Is Provided Under Annex “d” Of The Revised 2016 Irr Of Ra No. 9184. 2.2. The Procuring Entity Is Allowed To Determine The Terms Of Payment On The Partial Or Staggered Delivery Of The Goods Procured, Provided Such Partial Payment Shall Correspond To The Value Of The Goods Delivered And Accepted In Accordance With Prevailing Accounting And Auditing Rules And Regulations. The Terms Of Payment Are Indicated In The Scc. 3. Performance Security Within Ten (10) Calendar Days From Receipt Of The Notice Of Award By The Bidder From The Procuring Entity But In No Case Later Than Prior To The Signing Of The Contract By Both Parties, The Successful Bidder Shall Furnish The Performance Security In Any Of The Forms Prescribed In Section 39 Of The 2016 Revised Irr Of Ra No. 9184. 4. Inspection And Tests The Procuring Entity Or Its Representative Shall Have The Right To Inspect And/or To Test The Goods To Confirm Their Conformity To The Project Specifications At No Extra Cost To The Procuring Entity In Accordance With The Generic Procurement Manual. In Addition To Tests In The Scc, Section Iv (technical Specifications) Shall Specify What Inspections And/or Tests The Procuring Entity Requires, And Where They Are To Be Conducted. The Procuring Entity Shall Notify The Supplier In Writing, In A Timely Manner, Of The Identity Of Any Representatives Retained For These Purposes. All Reasonable Facilities And Assistance For The Inspection And Testing Of Goods, Including Access To Drawings And Production Data, Shall Be Provided By The Supplier To The Authorized Inspectors At No Charge To The Procuring Entity. 5. Warranty 6.1. In Order To Assure That Manufacturing Defects Shall Be Corrected By The Supplier, A Warranty Shall Be Required From The Supplier As Provided Under Section 62.1 Of The 2016 Revised Irr Of Ra No. 9184. 6.2. The Procuring Entity Shall Promptly Notify The Supplier In Writing Of Any Claims Arising Under This Warranty. Upon Receipt Of Such Notice, The Supplier Shall, Repair Or Replace The Defective Goods Or Parts Thereof Without Cost To The Procuring Entity, Pursuant To The Generic Procurement Manual. 6. Liability Of The Supplier The Supplier’s Liability Under This Contract Shall Be As Provided By The Laws Of The Republic Of The Philippines. If The Supplier Is A Joint Venture, All Partners To The Joint Venture Shall Be Jointly And Severally Liable To The Procuring Entity. Section V. Special Conditions Of Contract Gcc Clause 1 Delivery And Documents – For Purposes Of The Contract, “exw,” “fob,” “fca,” “cif,” “cip,” “ddp” And Other Trade Terms Used To Describe The Obligations Of The Parties Shall Have The Meanings Assigned To Them By The Current Edition Of Incoterms Published By The International Chamber Of Commerce, Paris. The Delivery Terms Of This Contract Shall Be As Follows: [for Goods Supplied From Within The Philippines, State:] “the Delivery Terms Applicable To This Contract Are Delivered To San Joaquin Mother Child Hospital, San Joaquin, Iloilo.risk And Title Will Pass From The Supplier To The Procuring Entity Upon Receipt And Final Acceptance Of The Goods At Their Final Destination.” Delivery Of The Goods Shall Be Made By The Supplier In Accordance With The Terms Specified In Section Vi (schedule Of Requirements). For Purposes Of This Clause The Procuring Entity’s Representative At The Project Site Is The Authorized Employee/official Of The Iloilo Provincial Government. Incidental Services – The Supplier Is Required To Provide All Of The Following Services, Including Additional Services, If Any, Specified In Section Vi. Schedule Of Requirements: A. Performance Or Supervision Of On-site Assembly And/or Start-up Of The Supplied Goods; B. Furnishing Of Tools Required For Assembly And/or Maintenance Of The Supplied Goods; C. Furnishing Of A Detailed Operations And Maintenance Manual For Each Appropriate Unit Of The Supplied Goods; The Contract Price For The Goods Shall Include The Prices Charged By The Supplier For Incidental Services And Shall Not Exceed The Prevailing Rates Charged To Other Parties By The Supplier For Similar Services. Packaging – The Supplier Shall Provide Such Packaging Of The Goods As Is Required To Prevent Their Damage Or Deterioration During Transit To Their Final Destination, As Indicated In This Contract. The Packaging Shall Be Sufficient To Withstand, Without Limitation, Rough Handling During Transit And Exposure To Extreme Temperatures, Salt And Precipitation During Transit, And Open Storage. Packaging Case Size And Weights Shall Take Into Consideration, Where Appropriate, The Remoteness Of The Goods’ Final Destination And The Absence Of Heavy Handling Facilities At All Points In Transit. The Packaging, Marking, And Documentation Within And Outside The Packages Shall Comply Strictly With Such Special Requirements As Shall Be Expressly Provided For In The Contract, Including Additional Requirements, If Any, Specified Below, And In Any Subsequent Instructions Ordered By The Procuring Entity. The Outer Packaging Must Be Clearly Marked On At Least Four (4) Sides As Follows: Name Of The Procuring Entity Name Of The Supplier Contract Description Final Destination Gross Weight Any Special Lifting Instructions Any Special Handling Instructions A Packaging List Identifying The Contents And Quantities Of The Package Is To Be Placed On An Accessible Point Of The Outer Packaging If Practical. If Not Practical The Packaging List Is To Be Placed Inside The Outer Packaging But Outside The Secondary Packaging. Transportation – Where The Supplier Is Required Under Contract To Deliver The Goods Cif, Cip, Or Ddp, Transport Of The Goods To The Port Of Destination Or Such Other Named Place Of Destination In The Philippines, As Shall Be Specified In This Contract, Shall Be Arranged And Paid For By The Supplier, And The Cost Thereof Shall Be Included In The Contract Price. Where The Supplier Is Required Under This Contract To Transport The Goods To A Specified Place Of Destination Within The Philippines, Defined As The Project Site, Transport To Such Place Of Destination In The Philippines, Including Insurance And Storage, As Shall Be Specified In This Contract, Shall Be Arranged By The Supplier, And Related Costs Shall Be Included In The Contract Price. Where The Supplier Is Required Under Contract To Deliver The Goods Cif, Cip Or Ddp, Goods Are To Be Transported On Carriers Of Philippine Registry. In The Event That No Carrier Of Philippine Registry Is Available, Goods May Be Shipped By A Carrier Which Is Not Of Philippine Registry Provided That The Supplier Obtains And Presents To The Procuring Entity Certification To This Effect From The Nearest Philippine Consulate To The Port Of Dispatch. In The Event That Carriers Of Philippine Registry Are Available But Their Schedule Delays The Supplier In Its Performance Of This Contract The Period From When The Goods Were First Ready For Shipment And The Actual Date Of Shipment The Period Of Delay Will Be Considered Force Majeure. The Procuring Entity Accepts No Liability For The Damage Of Goods During Transit Other Than Those Prescribed By Incoterms For Ddp Deliveries. In The Case Of Goods Supplied From Within The Philippines Or Supplied By Domestic Suppliers Risk And Title Will Not Be Deemed To Have Passed To The Procuring Entity Until Their Receipt And Final Acceptance At The Final Destination. 2.2 Partial Payment Is Not Allowed. 4 The Inspections And Tests That Will Be Conducted Are Through Physical Inspection. Item Number Description Quantity Total Delivered, Weeks/months 1 Alcohol ,ethyl, 70% Isoprophyl , Gallon 50 50 2 Battery Charger ,aa, 4's 2 2 3 Battery, Rechargeable, Aa, 4s 20 20 4 Bleaching Solution, 1 Gal, Original / Lemon 200 200 5 Bleaching Solution, Color Safe, 3600ml 150 150 6 Boots, Size 9 8 8 7 Boots, Size10 15 15 8 Broom, Soft, Thick 50 50 9 Bulb Capsule, 15w, Led Type 40 40 10 Bulb, Led, 9w 40 40 11 Chlorine Granules, 40 Kg,container 2 2 12 Clothes Pin, 1kg 5 5 13 Cockroach Killer Spray 15 15 14 Curtain, Thick, Blue, Abstract Design With Ring Holes, 7ft Length (one Design Only) 40 40 15 Detergent Powder, 2 Kg 150 150 16 Detergent Powder, 1 Kg 125 125 17 Dishwashing Liquid, 1 Gallon, Antibac 30 30 18 Disinfectant , Floor Tile Cleaner, 1gal, Antibac, Lemon/orange Scent 55 5 19 Disinfectant, Sodium Hypochlorite Solution, 10% Purity, 1 Gal 15 15 Section Vi. Schedule Of Requirements The Delivery Schedule Expressed As Weeks/months Stipulates Hereafter A Delivery Date Which Is The Date Of Delivery To The Project Site. 20 Door Mat, Cloth, Cotton 250 250 21 Dust Pan, Big 40 20 22 Electrical Tape, 16m 20 200 23 Fabric Conditioner, Gal 200 200 24 Feather Duster, 20 20 25 Floor Brush With Long Handle, Heavy Duty 20 20 26 Floor Matting L 5meters X W 1 Meter, Rubber, Coarse For Slippery Area, Gray 6 6 27 Garbage Bag Black,medium 2000 200 28 Garbage Bag Black, 37"x40" 6000 6000 29 Garbage Bag Green, 37"x40" 6000 6000 30 Garbage Bag Yellow, 37"x40" 6000 6000 31 Garden Hose,pvc, 1/2", High Quality 50 50 32 Glass Cleaner, Spray, 500 Ml 20 20 33 Hospital Bedsheet Set (1 Fitted, 1 Flat, 1 Pillowcase), Dark Green, 100% Cotton, L-80cm, W-25cm 50 50 34 Hospital Bedsheet Set (1 Fitted, 1 Flat, 1 Pillowcase), Mint Green, 100% Cotton, L-80cm, W-37cm 100 100 35 Industrial Gloves 100 100 36 Laundry Brush, Big 15 15 37 Laundry Gloves, Medium/large, Thick, Long 50 50 38 Liquid Hand Washing Soap, Gal 40 40 39 Mop,wooden Handle W/ Steel Mopholder, Heavy Duty, 100% Cotton 60 60 40 Mop Squeezer With Wringer, Heavy Duty 4 4 41 Mop, Long Dust Mop With Handle, 3layer, Flatbed 110cm Long, 100% Cotton, Heavy Duty 2 2 42 Pail, 24l Capacity 50 50 43 Paper Cup, 260cc 1500 1500 44 Paper Plate 1000 1000 45 Room Freshener Gel For Room 180 G, Assorted Scent 50 50 46 Sack, Thick, 50kg 4000 4000 47 Signage Board Stand (i.e Caution Wet Floor) 6 6 48 Scouring Sponge, Regular Size 50 50 49 Spray Bottle, Portable, Pressurize, 1l, Heavy Duty 25 25 50 Rag For Table, 100% Cotton 200 200 51 Tissue Paper, 2 Ply, Pull-up, Compatible To Tissue Dispenser 50 50 52 Tissue Dispenser Compatible To Tissue Paper 50 50 53 Toilet Bowl Brush W/ Continuous Handle 50 50 54 Toilet Bowl Cleaner, 900ml 20 20 55 Toilet Deodorant Cake, 100gms 300 300 56 Toilet Signage, Male, Green Background 50 50 57 Toilet Signage, Female, Green Background 50 50 58 Toilet Signage, Pwd, Senior Citizen, Pregnant Women , Green Background 2 2 59 Toilet Pump/plunger 29 29 60 Uv Germicidal Light Disinfection Lamp 2 2 61 Waste Bin, Pedal Type 50l Capacity, Color Black For Offices 20 20 62 Water Dipper, Big 50 50 63 Window Squeegee, Heavy Duty, With Long Handle 15 15 ___________________________________ Signature Over Printed Name Section Vii. Technical Specifications Bid No.: Sjh-24-592-b Item Specification Statement Of Compliance [bidders Must State Here Either “comply” Or “not Comply” Against Each Of The Individual Parameters Of Each Specification Stating The Corresponding Performance Parameter Of The Equipment Offered. Statements Of “comply” Or “not Comply” Must Be Supported By Evidence In A Bidders Bid And Cross-referenced To That Evidence. Evidence Shall Be In The Form Of Manufacturer’s Un-amended Sales Literature, Unconditional Statements Of Specification And Compliance Issued By The Manufacturer, Samples, Independent Test Data Etc., As Appropriate. A Statement That Is Not Supported By Evidence Or Is Subsequently Found To Be Contradicted By The Evidence Presented Will Render The Bid Under Evaluation Liable For Rejection. A Statement Either In The Bidder's Statement Of Compliance Or The Supporting Evidence That Is Found To Be False Either During Bid Evaluation, Post-qualification Or The Execution Of The Contract May Be Regarded As Fraudulent And Render The Bidder Or Supplier Liable For Prosecution Subject To The Applicable Laws And Issuances.] 1 Alcohol ,ethyl, 70% Isoprophyl , Gallon 2 Battery Charger ,aa, 4's 3 Battery, Rechargeable, Aa, 4s 4 Bleaching Solution, 1 Gal, Original / Lemon 5 Bleaching Solution, Colorsafe, 3600ml 6 Boots, Size 9 7 Boots, Size10 8 Broom, Soft, Thick 9 Bulb Capsule, 15w, Led Type 10 Bulb, Led, 9w 11 Chlorine Granules, 40 Kg,container 12 Clothes Pin, 1kg 13 Cockroach Killer Spray 14 Curtain, Thick, Blue, Abstract Design With Ring Holes, 7ft Length (one Design Only) 15 Detergent Powder, 2 Kg 16 Detergent Powder, 1 Kg 17 Dishwashing Liquid, 1 Gallon, Antibac 18 Disinfectant , Floor Tile Cleaner, 1gal, Antibac, Lemon/orange Scent 19 Disinfectant, Sodium Hypochlorite Solution, 10% Purity, 1 Gal 20 Door Mat, Cloth, Cotton 21 Dust Pan, Big 22 Electrical Tape, 16m 23 Fabric Conditioner, Gal 24 Feather Duster, 25 Floor Brush With Long Handle, Heavy Duty 26 Floor Matting L 5meters X W 1 Meter, Rubber, Coarse For Slippery Area, Gray 27 Garbage Bag Black, Medium 28 Garbage Bag Black, 37"x40" 29 Garbage Bag Green, 37"x40" 30 Garbage Bag Yellow, 37"x40" 31 Garden Hose,pvc, 1/2", High Quality 32 Glass Cleaner, Spray, 500 Ml 33 Hospital Bedsheet Set (1 Fitted, 1 Flat, 1 Pillowcase), Dark Green, 100% Cotton, L-80cm, W-25cm 34 Hospital Bedsheet Set (1 Fitted, 1 Flat, 1 Pillowcase), Mint Green, 100% Cotton, L-80cm, W-37cm 35 Industrial Gloves 36 Laundry Brush, Big 37 Laundry Gloves, Medium/large, Thick, Long 38 Liquid Hand Washing Soap, Gal 39 Mop,wooden Handle W/ Steel Mopholder, Heavy Duty, 100% Cotton 40 Mop Squeezer With Wringer, Heavy Duty 41 Mop, Long Dust Mop With Handle, 3layer, Flatbed 110cm Long, 100% Cotton, Heavy Duty 42 Pail, 24l Capacity 43 Paper Cup, 260cc 44 Paper Plate 45 Room Freshener Gel For Room 180 G, Assorted Scent 46 Sack, Thick, 50kg 47 Signage Board Stand (i.e Caution Wet Floor) 48 Scouring Sponge, Regular Size 49 Spray Bottle, Portable, Pressurize, 1l, Heavy Duty 50 Rag For Table, 100% Cotton 51 Tissue Paper, 2 Ply, Pull-up, Compatible To Tissue Dispenser 52 Tissue Dispenser Compatible To Tissue Paper 53 Toilet Bowl Brush W/ Continuous Handle 54 Toilet Bowl Cleaner, 900ml 55 Toilet Deodorant Cake, 100gms 56 Toilet Signage, Male, Green Background 57 Toilet Signage, Female, Green Background 58 Toilet Signage, Pwd, Senior Citizen, Pregnant Women , Green Background 59 Toilet Pump/plunger 60 Uv Germicidal Light Disinfection Lamp 61 Waste Bin, Pedal Type 50l Capacity, Color Black For Offices 62 Water Dipper, Big 63 Window Squeegee, Heavy Duty, With Long Handle Condition: 1. Partial Delivery Is Not Allowed ___________________________________ Signature Over Printed Name Section Viii. Checklist Of Technical And Financial Documents I. Technical Component Envelope Class “a” Documents Legal Documents ⬜ (a) Valid Philgeps Registration Certificate (platinum Membership) (all Pages);or ⬜ (b) Registration Certificate From Securities And Exchange Commission (sec), Department Of Trade And Industry (dti) For Sole Proprietorship, Or Cooperative Development Authority (cda) For Cooperatives Or Its Equivalent Document, And ⬜ (c) Mayor’s Or Business Permit Issued By The City Or Municipality Where The Principal Place Of Business Of The Prospective Bidder Is Located, Or The Equivalent Document For Exclusive Economic Zones Or Areas; And ⬜ (d) Tax Clearance Per E.o. No. 398, S. 2005, As Finally Reviewed And Approved By The Bureau Of Internal Revenue (bir). Technical Documents ⬜ (e) Statement Of The Prospective Bidder Of All Its Ongoing Government And Private Contracts, Including Contracts Awarded But Not Yet Started, If Any, Whether Similar Or Not Similar In Nature And Complexity To The Contract To Be Bid; And ⬜ (f) Statement Of The Bidder’s Single Largest Completed Contract (slcc) Similar To The Contract To Be Bid, Except Under Conditions Provided For In Sections 23.4.1.3 And 23.4.2.4 Of The 2016 Revised Irr Of Ra No. 9184, Within The Relevant Period As Provided In The Bidding Documents; And ⬜ (g) Original Copy Of Bid Security. If In The Form Of A Surety Bond, Submit Also A Certification Issued By The Insurance Commission; Or Original Copy Of Notarized Bid Securing Declaration; And ⬜ (h) Conformity With The Technical Specifications, Which May Include Production/delivery Schedule, Manpower Requirements, And/or After-sales/parts, If Applicable; And ⬜ (i) Original Duly Signed Omnibus Sworn Statement (oss); And If Applicable, Original Notarized Secretary’s Certificate In Case Of A Corporation, Partnership, Or Cooperative; Or Original Special Power Of Attorney Of All Members Of The Joint Venture Giving Full Power And Authority To Its Officer To Sign The Oss And Do Acts To Represent The Bidder. Financial Documents ⬜ (j) The Supplier’s Audited Financial Statements, Showing, Among Others, The Supplier’s Total And Current Assets And Liabilities, Stamped “received” By The Bir Or Its Duly Accredited And Authorized Institutions, For The Preceding Calendar Year Which Should Not Be Earlier Than Two (2) Years From The Date Of Bid Submission; And ⬜ (k) The Prospective Bidder’s Computation Of Net Financial Contracting Capacity (nfcc); Or A Committed Line Of Credit From A Universal Or Commercial Bank In Lieu Of Its Nfcc Computation. Class “b” Documents ⬜ (l) If Applicable, A Duly Signed Joint Venture Agreement (jva) In Case The Joint Venture Is Already In Existence; Or Duly Notarized Statements From All The Potential Joint Venture Partners Stating That They Will Enter Into And Abide By The Provisions Of The Jva In The Instance That The Bid Is Successful. Ii. Financial Component Envelope ⬜ (m) Original Of Duly Signed And Accomplished Financial Bid Form; And ⬜ (n) Original Of Duly Signed And Accomplished Price Schedule(s). Other Documentary Requirements Under Ra No. 9184 (as Applicable) ⬜ (o) [for Foreign Bidders Claiming By Reason Of Their Country’s Extension Of Reciprocal Rights To Filipinos] Certification From The Relevant Government Office Of Their Country Stating That Filipinos Are Allowed To Participate In Government Procurement Activities For The Same Item Or Product. ⬜ (p) Certification From The Dti If The Bidder Claims Preference As A Domestic Bidder Or Domestic Entity.
Closing Date4 Dec 2024
Tender AmountPHP 1.5 Million (USD 25.4 K)
Caraga Regional Hospital Tender
Healthcare and Medicine
Philippines
Details: Description Republic Of The Philippines Department Of Health Caraga Regional Hospital Surigao City Bids And Awards Committee Ooooooo ----------------------------------------------------------------------------------------------------------------------------- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ Invitation To Bid Ib No. 2024-12-11 (97) Supply And Delivery Of Laboratory Reagents For Clinical Microscopy, Hematology, Coagulation & Point Of Care Under Single-year Framework Agreement (early Procurement Activity) Abc: ₱ 15,676,000.00 ========================================================= 1. The Caraga Regional Hospital (crh), Through The Fy 2025 General Appropriation Act (gaa) Intends To Apply The Sum Of Being The Approved Budget For The Contract (abc) Of Fifteen Million Six Hundred Seventy Six Thousand Pesos Only ( Php 15,676,000.00 ) Under The Contract For The Supply And Delivery Of Laboratory Reagents For Clinical Microscopy, Hematology, Coagulation & Point Of Care Under Single-year Framework Agreement (early Procurement Activity)). Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening And Items Below Are Subject For A Competitive Bidding. This Is A Lot Bid. Line Item Code Description Quantity Unit Of Measure Unit Cost Total Cost 1 Lot 5 Clinical Microscopy 1 Lot Reagents For Fully Automated Complete Urine Analysis 35000 Test 100.00 3,500,000.00 Subtotal Lot 5 ₱ 3,500,000.00 2 Lot 6 Hematology - Cbc 1 Lot Complete Blood Count Set Of Reagents Inclusive Of Tri-level Controls 50000 Test 120.00 6,000,000.00 Subtotal Lot 6 ₱ 6,000,000.00 3 Lot 7 Coagulation 1 Lot Activated Partial Thrombin Time (aptt) Test 10000 Test 250.00 2,500,000.00 Prothrombin Time (pt) Test 12000 Test 250.00 3,000,000.00 Subtotal Lot 7 ₱ 5,500,000.00 4 Lot 8b Point Of Care (i-stat) 1 Lot Cartridge Capable Of Arterial Blood Gas With Electrolytes (25 Test/box) Compatible To Istat 20 Box 26,000.00 520,000.00 Cartridge Capable Of Coagulation (protime) Test (25 Test/box) Compatible To Istat 6 Box 26,000.00 156,000.00 Subtotal Lot 8b ₱ 676,000.00 Grand Total ₱ 15,676,000.00 Technical Specification And Terms Of Reference Lot 5 – Clinical Microscopy Item Description The Winning Bidder Shall Provide The Following • Complete Set Of Reagents For Urinalysis For 35,000 Tests • Compatible To Existing And Owned Machine Dirui Fus2000 1. Includes Reagent Strips, Sheath, Daily Controls For Sediments And Chemistry, Calibrators, Focus, Detergent, Standards Solution, And Other Reagents Necessary For Testing. 2. Free Use Of A Backup Machine Which Uses Same Reagents And Is Responsible For The Preventive Maintenance Of Their Own Machine. 3. Bidder Must Provide The Following For Free: • Lugols Iodine 200ml • Glass Slide - 40boxes (72pcs/box) • 35,000 Disposable Test Tubes Compatible To Machine • 45,000 Pieces Of Disposable Screw Cap Urine Container • 5 Boxes Applicator Sticks (plain, Non-sterile, Disposable Wooden Applicator Sticks With Uniform Cylindrical Shape And Smooth Finish) 1000pcs/box • 1 Set Of Katokatz Reagent At Least 200ml. (glycerin And Malachite Green) 4. Lis Connectivity Ready; Machine Must Be Connected To Caraga Regional Hospital Laboratory Information System Upon Installation. Supplier Will Shoulder Any Connectivity Costs. Lis Must Be Installed In The Machine/equipment Within 7 Working Days From The Delivery Of The Machine. Terms Of Delivery 50% Of Reagents, Supplies And Consumables To Be Delivered Within 7 Working Days From The Receipt Of The Notice To Proceed. The Remaining 50% Will Be Delivered Within 7 Working Days From Request/demand By The End User. Note: In Case Of None Delivery Of Reagents (and Trouble Of The Machine) But With Received P.o The Supplier Will Shoulder The Payments For Send-out Examinations. The Winning Supplier Must Present A Moa With Referring Laboratory For This Purpose. Lot 6 – Hematology Item Specification: 1. Reagents Must Be Compatible With The Sysmex Xn1000 Machine. This Includes: A. Diluent And Sheath Flow Agent (cell Pack) (20l/box) - 168 Boxes B. Non-cyanide Hemoglobin Reagent (sulfolyzer) (5l/box) - 24 Boxes C. Fluorescent Dye For Nrbc (lysercell Wnr) (5l/box) - 36 Boxes D. Lysing Solution For Wbc Differential Count (lysercell Wdf) (5l/box) - 24 Boxes E. Fluorescent Dye For Nrbc (fluorocell Wnr) (82ml X 2/box) - 12 Boxes F. Fluorescent Dye For Wbc (fluorocell Wdf) (42ml X 2/box) - 10 Boxes G. Diluent For Retic (cell Pack Dfl) (1l) - 6 Bots H. Fluorescent Dye For Retic (fluorocell Retic) (12ml X 2/pack) - 3 Pack Terms Of Reference 1. The Winning Supplier Must Provide The Following For Free Of Charge A. A Back-up Of Fully Automated Hematology Analyzer With License To Analyze Reticulocyte Count And Body Fluids Using The Same Reagent To Ensure Continuous Operation Despite Repairs Or Preventive Maintenance. Lis Connectivity Ready; Machine Must Be Connected To Caraga Regional Hospital Laboratory Information System Upon Installation. Supplier Will Shoulder Any Connectivity Costs. Lis Must Be Installed In The Machine/equipment Within 7 Working Days From The Delivery Of The Machine. B. 500 Trays Of 2 Ml Edta Test Tubes And 200 Trays Of 0.5 Ml Edta Microtainer Tubes. C. Tri-level Control (l, N, H) - At Least 2 Sets Per Month And As Needed D. Calibrator E. Washing Solution (120ml) - At Least 2 Bottles Per Month And As Needed 2. Material Safety Data Sheet 3. The Winning Supplier Is In Charge Of The Machine's Preventive Maintenance, Which Must Be Performed Twice A Month And As Needed. In The Event Of A Breakdown, The Machine Must Be Repaired Within Two Days Of The Reported Downtime Or May Provide A Backup Machine. If There Is A Major Cause For The Breakdown Or Parts Replacement, The Purchase Of Any New Parts Must Be Coordinated With Biomed For Approval. 4. Must Perform Machine Calibration And Will Provide Certificate Of Calibration And Traceability Every 6 Months. 5. Supplier Must Respond Within 3 Days To The Needs Of The End User Particularly On The Reagent For Continuous Operation Of The Laboratory Services. Terms Of Delivery • The Expiry Dates Of Reagents To Be Delivered Must At Least Be 2 Years From The Date Of Delivery As Specified In The Acceptance Report. • 50% Of Reagents, Supplies And Consumables To Be Delivered Within 7 Working Days From The Receipt Of The Notice To Proceed. The Remaining 50% Will Be Delivered Within 7 Working Days From Request/demand By The End User. Note: In Case Of None Delivery Of Reagents (and Trouble Of The Machine) But With Received P.o The Supplier Will Shoulder The Payments For Send-out Examinations. The Winning Supplier Must Present A Moa With Referring Laboratory For This Purpose. Lot 7 – Coagulation Technical Specification 1. Fully Automated, Brand-new Machine Capable Performing Examinations For Both Prothrombin Time (pt), Activated Partial Thromboplastin Time (aptt) With The Following Features Free Of Use: A. Prothrombin Time And Activated Partial Thromboplastin Time (aptt) Reagent Is Of Human Source. B. Random Access For Stat Requests C. With Seconds, Percent, Inr And Isi Unit For Prothrombin Time D. Capable Of Processing Directly From Extraction Tube Without Manually Transferring Serum/plasma. E. Able To Run / Process Fibrinogen Test. F. Reagents Refrigerated On Board G. Sample Time Flagging H. Auto Sample Handling I. Assays Continues While Loading Reagents Or Any Consumables J. Barcode Reading Of Samples 2. The Analyzer Be Equipped With Programs For: A. Daily Worklist (printable) B. Reagent Inventory Management System C. Quality Control Chart (levy - Jenning's Graph) 3. A Back - Up Machine Using The Same Reagent To Ensure Continuous Operation Despite Repairs Or Preventive Maintenance. 4. Lis Connectivity Ready; Machine Must Be Connected To Caraga Regional Hospital Laboratory Information System Upon Installation. Supplier Will Shoulder Any Connectivity Costs. Lis Must Be Installed In The Machine/equipment Within 7 Working Days From The Delivery Of The Machine. Terms Of References 1. The Winning Bidder Shall Provide The Following Free Of Charge: A. Basic Daily Controls (normal And Pathologic), Calibrators, Cleaning Solutions, Cuvettes/ Rotors, Sample Cups, And Other Consumables. B. A 24-placer Centrifuge And Stop Watch Or Timer. C. Distilled Water If Required By The Process D. 180 Trays Of 2 Ml Evacuated 3.2% Citrated Tube (100pcs. /tray) And E. 40 Trays Of 1 Ml Blue Top Tubes (100pcs. /tray) Pre-measured With Sodium Citrate Designed For The Collection Of Pediatric Blood Samples. 2. Reagents Of At Least 18 Months Expiry From The Date Of Delivery. 3. Product Must Adhere To Iso 13485:2016 Standards For Medical Laboratories, Ensuring Quality And Competence In Laboratory Testing Procedures Or Its Equivalent. 4. Material Safety Data Sheet 5. Training On How To Properly Operate The Equipment And How To Optimize Results. 6. The Supplier Should Have A Certified Product Specialist And Qualified Technical Support To Ensure After-sales Service And Product Support. 7. Preventive Maintenance Must Be Done Every Month And As The Need Arises. Repairs And Other Services Including Parts Of The Machine Are Free. 8. Must Provide Work Procedure, Quick Guide And Operating Procedure Manual (soft And Hard Copy). 9. Must Provide Calibration Certificate And Perform Machine Calibration Every 6 Months. 10. Must Possess A Certificate Of Exclusive Distributorship Or Its Equivalent. 11. Must Have A Certificate Of Product Registration. Terms Of Delivery 50% Of Reagents, Supplies And Consumables To Be Delivered Within 7 Working Days From The Receipt Of The Notice To Proceed. The Remaining 50% Will Be Delivered Within 7 Working Days From Request/demand By The End User. Note: In Case Of None Delivery Of Reagents (and Trouble Of The Machine) But With Received P.o The Supplier Will Shoulder The Payments For Send-out Examinations. The Winning Supplier Must Present A Moa With Referring Laboratory For This Purpose. Lot 8b - Point Of Care (i-stat) Terms Of Delivery The 30% Of The Reagents, Supplies And Consumables Will Be Delivered 7 Working Days Upon Receipt Of The Notice To Proceed. The Remaining 50% Will Be Delivered As Per Request/demand By The End User. Other Terms Of Reference Terms Of Payment. Payment Shall Be Made Upon Complete Delivery. Necessary Documents Are Required In Compliance With Auditing Rules And Regulations. Post-qualification The Bidder Shall Comply The Post-qualification Requirements Set By The Procuring Entity Especially During Product Demonstration Or Requiring For A Product Sample On A Given Schedule. Failure To Comply Shall Be Ground For Post-disqualification. The Procuring Entity Shall Require The Bidder To Deliver A Product Sample Or Demo To Caraga Regional Hospital Vicinity, Or To Undergo A Site Visit To The Nearest Hospital. Additionally, The Procuring Entity May Have Preferences Regarding How This Hospital Can Find Reliable And Easily Accessible Procedures During The Post-qualification Phase. Consequently, During This Phase, The Bidder Must Always Be Ready To Comply With Any Requirements Or Standards Made By The Procuring Entity. This Procurement Is A Lot Bid. Validity Of The Contract Without Prejudice To The Provision Of Applicable Laws, Rules And Guidelines, The Contract Shall Be Automatically Terminated Under The Following Conditions: A. When The Total Quantity Specified In The Contract Has Been Exhausted; Or B. For Any Justifiable Reason Ground Where The Contract Will Not Redound To The Benefit Of The Government Or There Is Violation Of The Contract. Repeat Order: 1. No Repeat Order For An Item In Contract Being Awarded Shall Be Allowed Until After The Procuring Entity Has Exhausted The Estimated Quantity For The Same Item Specified Therein Or After The Contract Has Expired, Whichever Comes First, And Subject To The Conditions Provided In Section 51 Of Ra 9184 And Its Irr. For This Purpose, For This Purpose, The Repeat Order Shall Be Availed Of Only Within Six (6) Months From The Date Of The Last Final Call-off. 2. In Case Repeat Order Is Allowed And Resorted To, The Twenty-five (25%) Maximum Allowable Quantity Shall Be Based On The Total Quantity Of Awarded Item. General Conditions All Other Rules Governing Contract Implementation And Termination Under Ra 9184 And Its Irr, And Relevant Procurement Policies Shall Be Applicable. Technical Specification And Other Terms Of Reference Are Hereby Posted In Philgeps And Form An Integral Part Of This Invitation To Bid. 2. The Crh Now Invites Bids For The Procurement Of The Above-captioned Project. Delivery Of The Goods Is Required Within The Period Specified Under Section Vi (schedule Of Requirements). Bidders Should Have Completed, Within Five (5) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. Section 23.4.1.3. (ra 9184) The Bidder Must Have Completed A Single Contract That Is Similar To This Project, Equivalent To At Least Twenty Five Percent (25%) Of The Abc. Slcc Must Be Within 5 Years From The Submission Of Bids. (based On The Completion Date). Slcc Shall Be The Same Or Similar In Nature, Which Shall Be Determined By The Bac. For Procurement Where The Procuring Entity Has Determined, After The Conduct Of Market Research, That Imposition Of Either (a) Or (b) Will Likely Result To Failure Of Bidding Or Monopoly That Will Defeat The Purpose Of Public Bidding: The Bidder Should Comply With The Following Requirements: A. Completed At Least Two (2) Similar Contracts, The Aggregate Amount Of Which Should Be Equivalent To At Least Fifty Percent (50%) In The Case Of Non-expendable Supplies And Services Or Twenty-five Percent (25%) In The Case Of Expendable Supplies] Of The Abc For This Project; And B. The Largest Of These Similar Contracts Must Be Equivalent To At Least Half Of The Percentage Of The Abc As Required Above. 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Nondiscretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) 9184, Otherwise Known As The “government Procurement Reform Act”. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra 5183. 4. Interested Bidders May Obtain Further Information From The Bids And Awards Committee (bac) Secretariat, Caraga Regional Hospital, Surigao City And Inspect The Bidding Documents At The Address Given Above During 8:00 Am – 5:00 Pm, Monday To Friday. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On November 19, 2024 – December 11, 2024 On Or Before 10:00 A.m. From The Address Above And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Specified Below: Bidding Schedule Pre-bidding Conference November 29, 2024 At 9:00 O’clock In The Morning Via Zoom Platform Link: Join Zoom Meeting Https://us06web.zoom.us/j/88636391490?pwd=kw2zvribcugbsvxtt6qugrfbmwxjya.1 Meeting Id: 886 3639 1490 Passcode: 058855 Deadline Of Submission Of Bids December 11, 2024 At 10:00 A.m... Via Online And Submit Your Bidding Documents To This Email Address: Crhbac2020@gmail.com . Opening Of Bids December 11, 2024 At 3:00 P.m. Via Zoom Platform. Link: Join Zoom Meeting Https://us06web.zoom.us/j/87428491783?pwd=uj6m1ify3bouow37phq5zffaltfgaa.1 Meeting Id: 874 2849 1783 Passcode: 912134 Complete Philippine Bidding Documents Please Click The Link Below For The Complete Pbd: Https://drive.google.com/drive/folders/1oayhxbwoo8hs1ngv7kouk3kklki6bily?usp=sharing Amount Of Bidding Documents: ₱ 5,000.00 Lot 5 Clinical Microscopy ₱ 10,000.00 Lot 6 Hematology (cbc) ₱ 10,000.00 Lot 7 Coagulation ₱ 1,000.00 Lot 8b Point Of Care (i-stat) Bidders Who Wish To Participate In All Categories Will Be Required To Pay The Amount Of Php 25,000.00 Only It May Also Be Downloaded Free Of Charge From The Website Of The Philippine Government Electronic Procurement System (philgeps) And The Website Of The Procuring Entity, Provided That Bidders Shall Pay The Applicable Fee For The Bidding Documents Not Later Than The Submission Of Their Bids. The Following Phlippine Bidding Documents Can Be Accessed In The Philgeps, To Wit: A. Technical Specification / Terms Of Reference/ List Of Items B. Instruction To Bidders: B.1. Documents To Be Submitted (checklist- This Will Be Discussed During The Pre-bid Conference) B.2. Memorandum Of Undertaking – Provision Thereof Is Strictly Implemented C. Guidelines On The Conduct Of The Electronic Submission And Receipt Of Bids By The Procuring Entity – Caraga Regional Hospital (crh) D. Philippine Bidding Documents 6. The Crh Will Hold A Pre-bid Conference On The Above-mentioned Date, Time And Venue, Which Shall Be Opened To Prospective Bidders. The Pre-bidding Conference And Opening Of Bids Shall Be Conducted Through Videoconferencing, Webinar Or Virtual. Please Send Your Intent To Participate To Our Email Address As Provided Below. 7. Bids Must Be Duly Received By The Bac Secretariat At Via Designated Email On Or Before December 11, 2024 2024 At 10:00 O’clock In The Morning. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 18. Bid Opening Shall Be On December 11, 2024 At 3:00 O’clock In The Afternoon At The Bac Conference Room, Beside Procurement Office, Caraga Regional Hospital, Rizal Street, Surigao City As Virtual / Electronic Bidding. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend At The Address Above. Late Bids Shall Not Be Accepted. 8. Furthermore, The Standard Philippine Bidding Document (pbd) Is Form And Part Of This Invitation In Accordance To Ra 9184 And Other Applicable Laws, Rules And Policy. 9. The Crh Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Section 41 Of Ra 9184 And Its Irr, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 10. The Opening And Receipt Of Bids Is Strictly Implemented Through Electronic Submission. Given The Covid-19 Pandemic, Procurement Activity Has Been Expedient And One Of This Is The Conduct Of Electronic Submission Of Bids. The Crh Thru The Bids And Awards Committee (bac) Has Submitted Certification, Certified By The Highest Official Managing The Information Technology, Describing The Electronic System Or Procedure To Be Used By The Crh For The Electronic Submission And Receipts Of Bids And A Statement That The Same Is Compliant With The Gppb Resolution No. 12-2020 Requirements. 11. Bidding Documents Shall Be Emailed To This Email Address, With Activated Password To: Crhbac2020@gmail.com. You May Deposit On Line For The Payment Of The Bidding Documents To This Account Below: Bank Name: Land Bank Of The Philippines Account Name: Caraga Regional Hospital-trust Fund Account Number: 0982 -1288 – 70 12. Furthermore, Deposit Slip Shall Be Submitted Via Email To: Crhprocurement.bac@gmail.com. 13. The Procuring Entity Will No Longer Accept Nor Entertain Any Form Of Bids Submission Except Electronic. Failure To Comply Electronic Submission Will Be Immediately Disqualified. Guideline On The Electronic Submission Is Hereby Attached. 14. Please Fill Up The Caraga Regional Hospital Supplier’s Registry To This Link: Https://bit.ly/crh_suppliersregistry 15. For Further Information, Please Inquire To: Bac Secretariat Caraga Regional Hospital. Rizal Street, Surigao City Tel. Nos. (086) 826-1575 Local 194 Direct Line: (086) 826-9058 Mobile Nos. 09850508783 (smart/tnt) 09539212832 (globe/tm) E-mail Address: Crhprocurement.bac@gmail.com Approved By: (sgd) Atty. Ma. Flordelin T. Ensomo, Cpa Attorney Iv Chairman, Bids And Awards Committee
Closing Date11 Dec 2024
Tender AmountPHP 15.6 Million (USD 265.9 K)
Adela Serra Ty Memorial Medical Center Tender
Healthcare and Medicine
Philippines
Details: Description Invitation To Bid For Procurement Of Medical Supplies –package 1 (early Procurement Activity) (epa) Ib No. 2024-11-26 (67) 1. The [adela Serra Ty Memorial Medical Center], Using A Single-year Framework Agreement, Through The [astmmc Fund] Intends To Apply The Sum Of Thirty-eight Million Three Hundred Thousand Six Hundred Ninety Pesos Only [38,300,690.00] Being The Abc To Payments Under The Contract For Each Item For The Procurement Of Medical Supplies – Package 1 (early Procurement Activity (epa)) With Ib No. 2024-11-26 (67). Bids Received In Excess Of The Total Cost Per Item Shall Be Automatically Rejected. 2. The [astmmc] Now Invites Bids For [procurement Of Medical Supplies – Package 1 (early Procurement Activity (epa)) With Ib No. 2024-11-26 (67)]. Delivery Of The Goods Is Required Within [10-15 Calendar Days] [after Issuance Of A Call-off]. Bidders Should Have Completed, Within [five Years] From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. A. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From [adela Serra Ty Memorial Medical Center] And Inspect The Bidding Documents At The Address Given Below During [8:00am To 12:00; 1:00 To 5:00pm, Monday Thru Friday]. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On [november 4 To 26, 2024] From The Given Address Below, Philgeps Website And Probac Facebook Page And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of Twenty-five Thousand Pesos Only [25,000.00]. The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees In The Manner Whether It Will Be Presented In Person Or Through Electronic Means. 6. The [astmmc] Will Hold A Pre-bid Conference On [november 12, 2024] At [09:30am, Bac Conference Room, 2nd Floor, Opd Bldg., Astmmc, Tandag City, Sds]and/or Through Video Conferencing Or Webcasting Via [meet.google.com/rbu-snjw-vga].}, Which Shall Be Open To All Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Below, On Or Before [november 26, 2024 At 09:00am]. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On [november 26, 2024 At 09:01am] At The Given Address Below And/or Via [meet.google.com/rbu-snjw-vga]. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. The [astmmc] Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: [dr. Dominador B. Toral] [bac Conference Room, 2nd Floor, Opd Bldg., Astmmc, Tandag City, Sds] [astmmcprocurement@gmail.com] [tel. No. 086-211-4306] Probac Facebook Page Https://www.facebook.com/astmmc.probac] 12. You May Visit The Following Websites: For Downloading Of Bidding Documents: [philgeps And Probac Facebook Page] 1 Abdominal Pack ,28x24 Mesh With Xray Liner,with 12" Loop 12"x12"x12 Ply Sterile (lap Sponge) 5000 Pc 225,000.00 2 Abdominal Suction Tubing Sterile Half Curved With Removable Handle, Vacuum Thumb Control, Crown Rip, Tube Length 12ft /suction Connecting Tube With Yankauer Handle Size 3/16", 2m, Sterile 5000 Pc 475,000.00 3 Absorbable Haemostatic Gelatin Sponge Non-woven Material Sterile (oxidized Regenarated Cellulose) 70x50x10mm 100 Pc 43,000.00 4 Airway (mouth Guard) No. 0,size-60mm, Sterile 40 Pc 1,440.00 5 Airway (mouth Guard) No. 00,size-50mm, Sterile 40 Pc 1,440.00 6 Airway (mouth Guard) No. 1,size-70mm, Sterile,white 200 Pc 7,200.00 7 Airway (mouth Guard) No. 2,size-80mm, Steile, Green 750 Pc 27,000.00 8 Airway (mouth Guard) No. 3,size-90mm, Sterile, Yellow 400 Pc 14,400.00 9 Airway (mouth Guard) No. 4,size-100mm, Sterile, Red 350 Pc 12,600.00 10 Airway (mouth Guard) No. 5,size-110mm,sterile, Blue 350 36 12,600.00 11 Anesthesia Breathing Circuit, 72" Expandable Tubing, Single Limb Circuit With Hch Filter And 3l Latex-free Airbag, Adult 200 Pc 170,000.00 12 Anesthesia Breathing Circuit,jackson Reese T-piece Breathing System With 0.5ml Open Tail Bag, 1.8m Length 20 Pc 17,000.00 13 Adhesive Paper Tape 1 Inch/non Woven Tape,12's 250 Box 52,500.00 14 Asepto Syringe 50cc, Sterile, Plastic With Long Tip 4000 Pc 120,000.00 15 Autoclave Tape(steam Indicator)1 Inch X50cm 400 Roll 86,000.00 16 Alcohol Swab/prep Pads With 70% Isopropyl Alcohol,200's 1000 Box 112,000.00 17 Alkytriamine Cationic Surfactant 25ml: 1liter Water Dilution High Level Disinfectant Sporicidal Solution/sterilant 1-5minutes (for Devices And Instruments) 70 Gal 1,400,000.00 18 Enzymatic Pre-soaking Solution With Disinfectant Pre-cleaner With Disinfectant 5ml: 1 Liter Water Dilution 10 Gal 200,000.00 19 Alkytriamine Cationic Surfactant 50ml: 1liter Water Dilution High Level Disinfectant Sporicidal Solution/sterilant For Large And Small Surfaces. (wall To Wall) 30 Gal 234,000.00 20 Armsling Large/adult 650 Pc 33,800.00 21 Bedpan, Plastic 2000 Pc 144,000.00 22 Bp Cuff Arm Cloth, Adult 250 Pc 43,250.00 23 Bonewax 2.5g, 12's 3 Box 10,080.00 24 Calibrated Glass, 210ml 1000 Pc 22,000.00 25 Cautery Pad Adult Compatible With The Existing Cautery Machine, With Cable 200 Pc 116,000.00 26 Cautery Cord W/ Tip Pencil, Sterile, Non Stick Tip 2500 Pc 300,000.00 27 Central Venous Catheter Double Lumen, 7fx12"(30cm) 20 Pc 92,000.00 28 Central Venous Catheter Triple Lumen, 7fx12"(30cm) 10 Pc 51,000.00 29 Cervical Collar, Large 100 Pc 33,000.00 30 Colostomy Bag, Adult (one-sided Comfort Panel And Tape Collar Pouch) With Individually Clip(provide Sample Atleast 2 Pcs) 600 Pc 180,000.00 31 Colostomy Bag, Pedia (one-sided Comfort Panel And Tape Collar Pouch) With Individually Clip(provide Sample Atleast 2 Pcs) 100 Pc 30,000.00 32 Cotton Applicator Tipped Stick, Sterile, 100's 250 Box 25,000.00 33 Ctg Paper (comptible To Eden And Sunray Machine)3pads/box 50 Box 65,000.00 34 Ctg Paper, 152mm X 90mm, 150p (compatible To Edan Machine) (themo) (provide At Least 1 Sample) 100 Pad 43,200.00 35 Chlorhexidine Acetate With Tulle Gras Dressing 10cm X 10cm 500 Pc 47,000.00 36 Disposable Gown Non-sterile,non Woven,water Resistant,soft,good Tensile Strength,10's 5000 Pack 1,625,000.00 37 Disposable Chest Drainage Bottle, 1600ml 300 Pc 180,000.00 38 Disposable Needle G-19, Needle Length 1",100's 350 Box 63,000.00 39 Disposable Needle G-26x1/2", 100's 30 Box 5,400.00 40 Disposable Syringe, W/ Needle 1cc Insulin, G-30x8mm,luer Lock,100's 350 Box 92,050.00 41 Disposable Syringe, W/ Needle 1cc,tuberculin,0.5x16mm,luer Lock, 100's 2000 Box 480,000.00 42 Disposable Syringe W/ Needle 3cc,g-23,needle Length 1",luer Lock, 100's 4000 Box 800,000.00 43 Disposable Syringe W/ Needle 5cc,g-23, Needle Length 1"luer Lock, 100's 3000 Box 600,000.00 44 Disposable Syringe W/ Needle 10cc,g-23, Needle Length 1", Luer Lock, 100's 4000 Box 920,000.00 45 Disposable Syringe W/ Needle 20cc, Luer Lock, 50's 600 Box 180,000.00 46 Disposable Syringe Without Needle 30cc, Luer Lock, 50's 600 Box 374,400.00 47 Disposable Syringe Without Needle 50cc, Luer Lock, 25's 1340 Box 723,600.00 48 Disposable Ecg Electrodes With Prelegged Ag/agcl Sensor, Adult,50's (provide Sample Atleast 5 Pcs) 1200 Pack 288,000.00 49 Disposable Ecg Electrodes With Prelegged Ag/agcl Sensor, Pedia,50's (provide Sample Atleast 5 Pcs) 100 Pack 24,000.00 50 Disposable Ecg Electrodes With Prelegged Ag/agcl Sensor, Neonate,50's (provide Sample Atleast 5 Pcs) 50 Pack 19,200.00 51 Disposable Razor 1700 Pc 25,500.00 52 Disposable Shoe Cover, 100's 700 Pack 140,000.00 53 Ecg Paper 80mm X 20mm 800 Roll 80,000.00 54 Endotracheal Tube Fr. 2.0,uncuffed, 10's 30 Box 9,300.00 55 Endotracheal Tube Fr. 2.5, Uncuffed,10's 30 Box 9,300.00 56 Endotracheal Tube Fr. 3.5, Uncuffed,10's 25 Box 7,750.00 57 Endotracheal Tube Fr. 4.0,uncuffed,10's 25 Box 7,750.00 58 Endotracheal Tube Fr. 6.5,cuffed,10's 30 Box 10,800.00 59 Endotracheal Tube Fr. 7.0,cuffed,10's 50 Box 18,000.00 60 Endotracheal Tube Fr. 7.5,cuffed,10's 160 Box 57,600.00 61 Endotracheal Tube Fr. 8.0,cuffed,10's 30 Box 10,800.00 62 Elastic Bandage 4"x 5y 7500 Roll 150,000.00 63 Elastic Bandage 6"x 5y 7300 Roll 219,000.00 64 Epidural Set/ Epidural Kit, G-18;15mm Spinal Needle Tip Protusion From Tuohy Needle;in Locked Position The Spinal Needle Is Free To Rotate,enabling 360 Degree Freedom For Drug Dispersal In Preferred Direction;excellent Drug Distribution Is Achieved Through Three Helically-located Lateral Eyes Within The Clear Catheter,minimising The Potential For The Localised Pooling Of Drug Solutions Within The Epidural Space;pencil Point Needles Are Designed To Reduce The Risk Of Post Dural Puncture Headache And Atraumatic Entry Into The Subarachnoid Space. (provide Sample 1pc) 200 Pc 642,000.00 65 Extension Tube With Needle Free Valve, Triple Lumen, 10-15cm (bring At Least 1 Sample) 1500 Pc 300,000.00 66 Face Mask, Disposable, Surgical, Medical Grade,earloop,non-woven, 3ply, 50's 8000 Box 800,000.00 67 Foley Bag Cath. 2 Way-silicone Coated Fr. 16, Needleless 5000 Pc 200,000.00 68 Gauze Swab, 4"x4"-8 Ply, 28x24 Mesh, Non-sterile,100's/pack 12000 Pack 1,920,000.00 69 Gauze Swab 40's, 28x24 Mesh, 2"x2"x8 Ply Unsterile,100's 1000 Pack 150,000.00 70 Gauze Sponge,28x24 Mesh,with X-ray Liner,4"x8"x16 Ply, Sterile, 10's (pre-cut) Folded 5000 Pack 470,000.00 71 Gauze Roll, Surgical, With X-ray Liner 36"x100y (fine Mesh, 2 Ply) 28x24 Mesh 35 Roll 35,000.00 72 Gigli Saw (individually Wrapped) 100 Pc 60,000.00 73 Hernia Mesh 7.6cmx15cm (monofilament Knitted, Polypropylene Tissue Reconstruction Prosthesis/standard Hernia Kit 7.5 Cm X 15 Cm, Rectangle, Soft Polypropylene Mesh, Oxidized Regenerated Cellulose (orc) Knitted Fabric, (polydioxanone) Suture Polymer Film 100 Pc 345,000.00 74 Humidifier Sterile Water, 340 Ml 1000 Bottle 200,000.00 75 Ice Bag 6" 400 Pc 40,000.00 76 Internal Jugular Catheter, Double Lumen, Hemodialysis Kit (provide Sample Atleast 1 Pc) 120 Pc 720,000.00 77 Iv Flow Regulator With Pediatric Set (60 Drops/ml)(provide Sample Atleast 2 Pcs) 800 Pc 464,000.00 78 Iv Flow Regulator With Adult Set (30 Drops/ml) (provide Sample Atleast 2 Pcs) 1000 Pc 580,000.00 79 Laparotomy Pack, Sterile (5pcs Surgical Gowns, 5pcs Hand Towels, 1 Laparotomy Drape With Fenestration, 4pcs Square Off Drape With Adhesive, 1pc Mayo Cover, 1pc Suture Bag, 1pc Back Table Cover) 100 Pack 330,000.00 80 Lubricating Jelly, 150 Grams 800 Tube 120,000.00 81 Lubricating Jelly, 5 Grams 5000 Sachet 35,000.00 82 Nasal Oxygen Cannula, Adult 10000 Pc 200,000.00 83 Nasal Oxygen Cannula, Neonate 400 Pc 8,000.00 84 Nasal Oxygen Cannula, Pedia 2000 Pc 36,000.00 85 Nebulizer With Tee,7ft Tubing And Mouthpice, 6ml 10000 Pc 480,000.00 86 Nasogastric Tube Fr. 5 With Radiopaque Line; No Cover, Fits 100cc Asepto Syringe; Silicon 300 Pc 4,500.00 87 Nasogastric Tube Fr. 8 With Radiopaque Line; No Cover, Fits 100cc Asepto Syringe; Silicon, Length 105cm 500 Pc 7,500.00 88 Nasogastric Tube Fr. 14 With Radiopaque Line, 105cm; No Cover, Fits 100cc Asepto Syringe; Silicon, Length 105cm 800 Pc 30,400.00 89 Nasogastric Tube Fr. 16 With Radiopaque Line, 125cm; No Cover, Fits 100cc Asepto Syringe; Silicon, Length 125cm 2000 Pc 76,000.00 90 Non-rebreather Oxygen Mask, Adult,with Non-kink Oxygen Tubing, Oxygen Reservoir Bag 300 Pc 18,000.00 91 Oxygen Mask With Tubing, Adult 5000 Pc 200,000.00 92 Oxygen Mask With Tubing Infant 600 Pc 24,000.00 93 Oxygen Mask With Tubing Pedia 1000 Pc 40,000.00 94 Patiend Id Band, Adult, (white),100's 400 Box 120,000.00 95 Patiend Id Band, Pedia, (blue),100's 100 Box 30,000.00 96 Patiend Id Band, Pedia, (pink),100's 100 Box 30,000.00 97 Pvc Manual Resuscitator Set, Adult, Individually Boxed 2000 Set 3,000,000.00 98 Pvc Manual Resuscitator Set, Pedia, Individually Boxed 500 Set 300,000.00 99 Pvc Manual Resuscitator Set, Neonate, Individually Boxed 300 Set 180,000.00 100 Penrose Drainage Tubing 1/4"x18",sterile 100 Pc 2,400.00 101 Povidone 10% Solution 500 Gal 650,000.00 102 Povidone 7.5 % Cleanser 200 Gal 252,000.00 103 Plaster Of Paris, Fast Setting With Gypsum Powder And Leno Gauze 6 Inches X 5 Yards 1500 Roll 255,000.00 104 Surgical Plaster Creamy White Color, 3",2",1" And 1/2"(provide Sample At Least 2 Roll) 1300 Tube 4,030,000.00 105 Sodalime (soda Sorb),38 Lbs (1724kgs) 25 Pail 212,500.00 106 Spinal Needle Size: 0,53 X 88mm / 25g X 3 1/2", Sterile 4000 Pc 800,000.00 107 Suction Cath. Fr. 5 With Thumb Control Valve, 50-60cm Length 1400 Pc 22,400.00 108 Suction Cath. Fr. 8 With Thumb Control Valve, 50-60cm Length 3000 Pc 48,000.00 109 Suction Cath. Fr. 14 With Thumb Control Valve, 50-60cm Length 3500 Pc 56,000.00 110 Suction Cath. Fr. 16 With Thumb Control Valve, 50-60cm Length 6500 Pc 104,000.00 111 Surgical Blade # 10, Sterile,100's 40 Box 16,800.00 112 Surgical Blade # 11, Sterile,100's 30 Box 11,160.00 113 Surgical Blade # 20, Sterile,100's 40 Box 16,800.00 114 Surgical Cap,non Woven Buoffant, Blue, Double Elastic, 24", 100's 1200 Pack 196,800.00 115 Skin Stapler, Clear Cartridge With Centerline Pointer And Visual Access 35 W 2000 Pc 600,000.00 116 Surgical Scrub Brush Impregnated With Chlorhexidine Gluconate, Soft Sponge And Bristles, Individually Packed With Dispenser, 30's 600 Box 1,209,600.00 117 Sterilization Reel 10 Cm X 100 Cm (4"), Steam Sterilization 15 Roll 23,100.00 118 Sterilization Reel 30mm X 100m (12"), Steam Sterilization 15 Roll 104,400.00 119 Surgical Stapler Remover, 10's 10 Box 10,000.00 120 Thoracostomy (ctt) Tube Fr. 32/thoracic Drainage Catheter 80 Pc 8,960.00 121 Thoracostomy (ctt) Tube Fr. 36/thoracic Drainage Catheter 80 Pc 8,960.00 122 Tracheostomy Set Tube Cuffed With Inner Cannula, Size 7.0 10 Pc 35,100.00 123 Umbilical Cord Clamp Thick With Shaft Safety Security Lock, With Tight Teeth-maintain Tight Seal, Applies Consistent Constant Pressure On Any Size Cord As Cord Shrinks. (provide Sample Atleast 5 Pcs) 5300 Pc 63,600.00 124 Urine Bag (urobag), Adult, Capacity 2000ml,push Pull Valve, With Hook, Sterile (provide Sample Atleast 5 Pcs) 5500 Pc 137,500.00 125 Ultra Transmission Gel, 280ml 100 Tube 20,000.00 126 Underpads Super Absorbable ,23" X 36",25's 650 Pack 406,250.00 127 Urine Collector, Pedia, Capacity 100ml 5000 Pc 75,000.00 128 Urine/stool Cup Plastic,transparent, Sterile, Individually Packed,40ml 100000 Pc 2,000,000.00 129 Urinal Plastic, Male, 1000ml 2300 Pc 115,000.00 130 Vascular Catheter, Permanent Hemodialysis Catheter Splint Type-fr. 14.5f X 24cm With Stylet 70 Pc 1,869,000.00 131 Wadding Sheet 6x5y 2000 Roll 136,000.00 132 Wooden Tongue Depressor, Sterile 100's 150 Box 24,000.00 133 Wound Drainage /closed Wound Drainage System Bulb Type, 125ml Reservoir, 7mm Drain & 3/16" Trocar,sterile 400 Pc 952,000.00 134 Wound Dressing, 9cmx25cm 300 Pc 60,000.00 135 3-way Stop Cock 300 Pc 6,000.00
Closing Soon26 Nov 2024
Tender AmountPHP 38.3 Million (USD 649.7 K)
University Of The Philippines Tender
Healthcare and Medicine
Philippines
Details: Description Supply Of Various Simulation Equipment For Clinical Simulation Laboratory Pelvic Simulator With Virtual System Specifications ● Enhance Knowledge Of Pelvic Anatomy And Acquire The Comprehensive Skills Required To Accurately Perform Pelvic Exams ● Combines A Physical Mannequin With A Computerized 3d Virtual System ● Sensors Are Placed On The Trainee’s Fingers Which Are Used In Conjunction With The Mannequin And 3d Virtual Model ● Provides Real-time Indication Of Finger Palpation, Downward Press On The Abdomen And Cervix Manipulation ● Interchangeable Anatomies Are Easily Replaced To Represent Normal And Pathological Anatomical Structures ● Comes With A Height-adjustable Cart ● Curriculum Videos Included For Online Learning And Self-instruction ● Self-learning With Skill And Procedural Tasks ● Anatomical Labeling, Organ Recognition System ● Palpation Or Movement Is Reflected To Provide A True-to-life Image Of Internal Pelvic Actions ● Anatomical Software Customization: Allows Learner To Choose The Anatomies And Content To Be Included In The Training Or Testing Session ● Performance Reports/ Metrics At The End Of Each Training Session Allow The Learner And The Trainer To Review Practice Results Components: ● All-in-one Computer ● Mannequin ● Platform Base ● Finger Sensors ● Speculum And Interchangeable Pap Test Tool (interchangeable Pap Test Tool Includes Cytobrush And Cervical Broom) ● 6 Interchangeable Anatomical Units (normal Uterus, Ovarian Cyst, Multiparous Uterus, Large Fibroid, Ectopic Pregnancy, And Retroflexed Uterus) ● Control Unit ● Wireless Keyboard And Mouse ● Foot Pedal Display Cart Components: ● Computer Tray ● Keyboard And Mouse Tray ● Rotating Mannequin Table ● Table-height Adjustment Mechanism ● Control Unit Tray Simulation Processing Unit: ● Computer ● Windows Os-based ● At Least 22” Touch Screen Physical Dimensions: ● Platform Size: At Least 20.8”(l) X 18.8”(d) X 5.8”(h) ● Control Unit: At Least 15”(l) X 9.5”(d) X 4.8”(h) Electrical And Environmental Characteristics: ● 100-240 V~, 50/60 Hz, 3.2a ● Operation Temperature: Range 10-30°c ● Relative Humidity: Maximum 90%: ● Cloud Web-based Management System ● User Friendly Simulator And Curricula Administration ● Customize And Design Courses And Curricula ● Allows Learner Progress Monitoring And Setting Training Goals Modules: 1. Anatomical Recognition ● In The Module, The User Palpates The Anatomical Mannequin The Same Way It Is Done When Performing Pelvic Procedures On Live Patients ● The Realistic Physical Mannequin Provides The Trainee With A Very Accurate And True-to-life Palpation Sensation ● Customization Allows The Course Director To Choose The Relevant Anatomies And Content To Be Included In The Training Session ● Consists Of At Least Two (2) Modes: Anatomical Recognition Practice Mode And Anatomical Recognition Test Mode 2. Pelvic Exam ● Provided With Interchangeable Anatomies That Represent Different Exam Types ● These Anatomies Enable Trainees To Virtually Encounter And Learn Various Pelvic Conditions Before They Perform The Exam On A Live Patient ● Trainees Gain The Ability To Recognize Normal And Abnormal Gynecological Findings And Practice Using The Proper Techniques To Perform Pelvic Exams ● Dynamic Anatomical Behavior: The Palpated Organs In The Virtual Model On The Screen Move In Synchronization With The Mannequin, Allowing The Learner To Receive Real-time Feedback On Movements Inside The Pelvic Cavity ● Consists Of At Least Two (2) Modes: Pelvic Exam Practice Mode And Pelvic Exam Test Mode 3. Speculum Examination And Pap Test ● Includes A Self-guided Step-by-step And A Test Case For Cervix Examination Using A Speculum And Perform A Pap Test ● Use True-to-life Speculum And Pap Test Tools Including A Cytobrush And A Cervical Broom ● Connected To A Virtual Model, Trainee Can Track Patient Discomfort During Examination, Accuracy Of Tools Position And Receive Feedback Through The Performance Report ● Visualization Of Speculum And Pap Smear Tools In Virtual Anatomical Model Assist In Orientation ● Dynamic Anatomical Behavior: Vaginal Movement Is Reflected To Provide A True-to-life Image Of Internal Pelvic Actions Adult Auscultation Training Simulator Specifications For Training Different Heart, Lung And Bowel Sounds. The Sounds Library Conforms To American Thoracic Society Guidelines. ● At Least 35 Heart, 18 Lung And 12 Abdomen Sounds ● Anterior And Posterior Auscultation Points ● All Auscultation Points Light Up ● Transmit Sounds To External Speakers ● Compatible With A Real Stethoscope Challenge Assessment Skills From Clear Clinical Findings To Detecting Faint Murmurs. The Flexible Operating Tablet Allows You To: ● Activate Or Deactivate Auscultation Points And Backlighting Individually ● Adjust Volume And Intensity Of Sounds ● Change Hr And Rr For A Sound That Is Currently Being Reproduced ● Compare Sound Recordings ● Sound Matches Ecg Diagrams And Other Vital Parameters Cardiac Auscultation 1. Normal Heart Sound 2. Split First Heart Sound 3. Split Second Heart Sound 4. Third Heart Sound (gallop) 5. Fourth Heart Sound (gallop) 6. Functional Murmur 7. Diastolic Murmur 8. Opening Snap 9. Holosystolic Murmur 10. Early Systolic Murmur 11. Mid-systolic Murmur 12. Continuous Murmur 13. Austin Flint Murmur 14. Pericardial Rub 15. Graham Steel Murmur 16. Aortic Valve Regurgitation 17. Aortic Valve Stenosis 18. Aortic Stenosis And Regurgitation 19. Congenital Aortic Stenosis 20. Mitral Valve Regurgitation 21. Mitral Valve Stenosis 22. Mitral Valve Prolapse 23. Pulmonary Valve Stenosis 24. Pulmonary Valve Regurgitation 25. Tricuspid Valve Regurgitation 26. Coarctation Of The Aorta 27. Hypertrophic Cardiomyopathy 28. Patent Ductus Arteriosus 29. Atrial Septal Defect 30. Ventricular Septal Defect 31. Acute Myocardial Infarction 32. Congestive Heart Failure 33. Systemic Hypertension 34. Acute Pericarditis 35. Dilated Cardiomyopathy Auscultation Of Lungs 1. Bronchial Breath Sounds 2. Bronchovesicular Sounds 3. Vesicular Breath Sounds 4. Diminished Vesicular Breath Sounds 5. Coarse Crackles 6. Fine Crackles 7. Wheezes 8. Rhonchi 9. Gurgling Rales 10. Stridor 11. Pleural Friction Rub 12. Cavernous Breath Sound 13. Abnormal Harsh Bronchovesicular Breath Sounds 14. Asthma 15. Covid-19 16. Left-sided Pneumothorax 17. Right-sided Pneumothorax 18. Pneumonia Abdomen Auscultation 1. Normal Bowel Sound 2. Hyperactive Sounds 3. Hypoactive Sounds 4. Borborygmus 5. Capotement 6. Peritoneal Friction Rub 7. Normal Bowel Sound With Bruits 8. Irritable Bowel Syndrome 9. Diarrhea 10. Ulcerative Colitis 11. Crohn’s Disease 12. Functional Intestinal Obstruction 13. Paralytic Ileus Bluetooth Compatible Adult Full-body Resuscitation Manikin Specifications A Full-body Cpr Manikin With A Rechargeable Battery, Designed To Represent A Standard Adult Cardiac Arrest Patient (in Terms Of Required Chest Compression Force). It Simulates An Adult Of Average Physiology And Is Designed For Realistic Training In Basic Life Support Techniques Following International Recommendations. ● High-performance Cpr Training For Professional First Responders ● The Airway (aw) Head Is Designed For Supraglottic (sg) Intubation Supporting The Protocol For Doing Endotracheal (et Or Eti) Intubation In A Resuscitation Team Training Setting ● The Aed Skin Includes A Connector To Real And Simulated Aed Trainers, Enabling Aed Trainings In A Resuscitation Team Training Setting ● Enables Resuscitation Team Training Or Skills Training ● Erc, Aha And Srfac Guidelines Compliant Cpr Real Time Feedback To: ● Compression Depth, Rate, Release ● Ventilation Volume And Hand Placement ● Improvement Hints And Guided Debrief ● Multiple Chest Stiffnesses With Qcpr Feedback Device Includes: ● Full Body Manikin With Rechargeable Battery (1) ● Trolley Bag (1) ● 45kg Compression Spring Installed (1) ● 2 Extra Compression Springs (30kg And 60kg) (1) ● Training Pads Multi (1) ● Manikin Wipes Pkg (4) ● Important Product Information (1) ● User Guide (1) ● Airway Assemblies (2) ● Usb A-c (1) ● Ac Power Adapter Usb 2a (1) Bluetooth Compatible Child Full-body Resuscitation Manikin Specifications A Professional-grade Pediatric Cpr Manikin Designed To Represent A 5–6-year-old Boy, Which Enables Professional First Responders To Practice Cpr Skills And High-performance Team Training. The Manikin Is Bluetooth Enabled For Qcpr Feedback Device. ● Enables Resuscitation Team Training Or Skills Training ● Erc, Aha And Srfac Guidelines Compliant Cpr Real Time Feedback To: ● Compression Depth, Rate, Release ● Ventilation Volume And Hand Placement ● Improvement Hints And Guided Debrief With Qcpr Feedback Device Includes: ● Full-body Manikin With Jacket And Shorts ● Soft Carry Case That Doubles As Training Mat ● Pulse Bulb ● Manikin Wipes ● Face Masks ● At Least 2 Junior Airways ● Product Information ● User Guide ● At Least 2 Airway Assemblies, Usb A-c ● Ac Power Adapter Usb 2a ● 4 Aa Size Batteries Bluetooth Compatible Infant Full-body Resuscitation Manikin Specifications A Professional-grade Infant Cpr Manikin Designed To Represent A 3-month-old Baby, Which Enables Professional First Responders To Practice Cpr Skills And High-performance Team Training. The Manikin Is Bluetooth Enabled For Qcpr Feedback Devices. ● Facilitates Resuscitation Team Training Or Skills Training ● Erc, Aha And Srfac Guidelines Compliant Cpr Real Time Feedback For: ● Compression Depth, Rate, Release ● Ventilation Volume And Hand Placement ● Improvement Hints And Guided Debrief With Qcpr Feedback Device Includes: ● Full-body Manikin With Onesie Clothing And Rechargeable Battery ● Carry Case 20 L ● Pulse Bulb ● At Least 5 Disposable Airways ● 2 Baby Standard Head Face Skins ● Manikin Wipes ● Baby Blanket ● Qcpr Armband ● Product Information ● User Guide ● At Least 2 Airway Assemblies ● Usb A-c ● Ac Power Adapter Usb 2a Blood Pressure Measurement Trainer Specifications Lifelike, Adult Arm With An Electronic Trainer Designed For Training The Procedure Of Nibp Measurement. ● Palpable Antecubital Pulse ● Blood Pressure Trainer With Lcd Guided Operation ● Systolic, Diastolic, Heart Rate And Auscultatory Gap Are Programmable ● Representation Of Both Systolic And Diastolic Pressures ● Indication Of Gauge Reading As Pressure Is Increased Or Decreased ● Adjustable Volume Adult Airway Management Trainer Specifications ● Manually Inflatable Tongue To Simulate Obstructed Airway Or Tongue Edema ● Anatomically Correct Internal Anatomy Facilitates Airway Management Skills Using Manual Maneuvers And Mechanical Devices ○ Updated Airway Allows For Insertion Of Standard Airway Devices With The Addition Of The Lma, Combitube And King Lt ○ Oropharyngeal And Nasopharyngeal Airway Insertion ○ Endotracheal And Right Mainstem Intubation ○ Needle Or Surgical Cricothyrotomy ○ Retrograde Intubation ○ Bag-valve-mask Ventilation ○ Tracheal Suctioning Pediatric Airway Management Trainer Specifications ● Anatomically Accurate Airway ● Pediatric Torso ● Oropharyngeal And Nasopharyngeal Airway Insertion ● Endotracheal Tube Insertion And Securing ● Bag-valve Mask Ventilation ● Tracheal Suctioning ● Manually Generated Carotid Pulse ● Closed Chest Compressions Includes: ● 1 Pediatric Torso Trainer ● 1 Can Of Manikin Lubricant ● 1 Carry Case ● Directions For Use Infant Airway Management Trainer Specifications Realistic Anatomy Of A Three-month-old Infant For Teaching And Practicing Basic And Advanced Airway Management Skills. ● Realistic Representation Of Human Anatomy, Tissue, And Skin Material ● Allows Students To Undertake Training That Is Directly Transferable To The Clinical Setting ● Minimal Maintenance And Robust Design Enable Cost Effective Training ● A Base Plate Mount Allows Stable Practicing Conditions And Easy Transportation ● The Cover Prevents Dust From Coming Into Contact With The Head During Storage Product Features: ● Realistic Anatomy Of The Tongue, Oropharynx, Epiglottis, Larynx, Vocal Cords, And Trachea ● Practicing Of Oral And Nasal Intubation ● Practicing Use Of Lma (laryngeal Mask Airway) ● Correct Tube Placement Can Be Checked By Practical Inflation Test ● Bag-valve-mask Ventilation Can Be Practiced ● Sellick Maneuver Can Be Performed ● Stomach Inflation ● Realistic Tissue Simulation Leopold’s Maneuvers Task Trainer Specifications Comprehensive Maternal Body Set For Skills Training In Labor And Delivery. Combination Of Modules Offer A Variety Of Skills Training Features ● Realistic Reproduction Of The Birth Canal Allows For Pelvic Examination In Accordance With The Progress Of Delivery. ● The Ability To Perform Various Techniques (mcroberts Position, Woods Screw Method, Etc.) In Fetal Malposition And Shoulder Dystocia. Training Skills / Applications ● Delivery ● Pelvic Examination ● Normal Delivery ● Delivery Of Placenta And Umbilical Cord ● Reproduction And Handling Of Shoulder Dystocia And Fetal Malposition ● Vacuum Extraction ● Forceps Delivery ● Breech Delivery ● Delivery Of The Placenta ● Treatment Of The Fetus ● Umbilical Cord Entanglement ● Umbilical Cord Clamping And Cutting ● Palpation Of The Anterior/posterior Fontanels ● Suctioning Procedures Through Mouth And Nose Set Includes At Least The Following ● 1 Maternal Body ● 1 Skin Cover ● 2 Clamps ● 1 Fetus ● 1 Placenta ● 1 Umbilical Cord ● 3 Umbilical Cords For Omphalotomy ● 5 Velamen Sheets ● 1 Lubricant ● 1 Bottle For Lubricant ● 1 Talcum Powder ● 1 Towel ● 1 Instruction Manual Wound Care Task Trainer – Leg Specifications Wound Care Task Trainer Molded From An Actual Patient For True-to-life Realism. The Following Conditions* Are Presented: ● Venous Ulcers ● Cellulitis ● Stasis Dermatitis ● Varicose Veins ● Hemosiderin Staining Vasculitis ● Lipodermatosclerosis ● Calciphylaxis ● Pyoderma Grangrenosum ● Healed Foot Ulcer ● Fungal Thickened Toenails ● Maceration ● Diabetic Ulcer ● Atrophie Blanche ● Pitting Edema ● Reticular And Telangiectasia Veins. The Top Of The Leg Model Has A Unique Molded-in Swivel Fixture That Permits The Leg To Be Rotated A Full 360 Degrees For Easy Visualization. Wounds Associated With Venous Disease And Other Wounds On The Lower Leg And Foot Are Often Extremely Painful For The Patient, Thus Adding Urgency To Their Effective And Efficient Identification And Treatment. Includes A Display Stand Which Permits The Trainer To Pivot From Above The Knee And Rotate 360 Degrees, Providing A Realistic Experience In Supporting The Leg While Practicing Compression Wrapping, Dressing Changes Or Identifying Conditions In A Teaching Situation. Pediatric Iv Training Hand Specifications Set Of Pediatric Hands For Practicing Iv Features 1. Fingers And Dorsum Of Hand Are Flexible, Able To Be Gripped, And Repositionable As In Real-life Procedures 2. Two Puncture Sites On The Back Of The Hand 3. Practice Dressing And Securing The Cannula Training Skills / Applications ● Pediatric Dorsal Veins Injection ● Blood Collection ● Intravenous Infusion Set Includes: ● 2 Injection Arm-hands (one-year-old) ● 2 Injection Arm-hands (three-year-old) ● 2 Stands ● 1 Circulation Pump ● 10 Cotton Swabs ● 1 Spoon ● 1 Plastic Jar ● 1 Plastic Beaker ● 1 Storage Case ● 1 Instruction Manual Pediatric Iv Training Arm Specifications Lifelike Pediatric Arm Reproduction With Replaceable Skin And Multi-vein System Designed For Peripheral Intravenous Therapy. ● Venipuncture Possible In The Antecubital Fossa And Dorsum Of The Hand ● Accessible Veins Include Median, Basilic And Cephalic ● Arm Will Articulate To Pediatric Manikins And Task Trainers Kit Includes: ● 1 Pediatric Iv Arm - Right ● 1 Replacement Skin And Multi-vein System ● 1 Bottle Red Simulated Blood, ● 1 Can Of Manikin Lubricant ● 1 Blood Bag With Tubing And Connector ● 1 Clamp And Hook ● 1 Set Of Shoulder Attachment Hardware Pediatric Clinical Skills Trainer (for Ngt/ogt, Catheterization, Iv Insertion) ● Realistically Representing At Least, A Six-year-old Child For Skill And Scenario-based Training Of The Care And Management Of A Variety Of Pediatric Patients. For Clinical Training Of Common And Uncommon In-hospital Pediatric Patients Including Wound Assessment And Care, First Aid, And Child Abuse Training. ● Provides Training Targeting Key Skills Specific To Pediatric Care Providers. Designed To Meet The Training Requirements For Pediatric Patient Care And Helps Facilitate Delivery Of Consistent Simulations Into Nursing Curriculums. Features: 1. Articulating Iv Arm Allows For Practice Of Iv Cannulation, Medication Administration And Site Care And Maintenance. Venipuncture Possible In The Antecubital Fossa And Dorsum Of The Hand. Accessible Veins Include Median, Basilic And Cephalic. 2. Interchangeable Male And Female Genitalia Allow For Complete Urinary Catheterization. Enema Procedures May Also Be Performed. 3. Head With Anatomical Landmarks, Trachea, And Esophagus Along With Simulated Lungs And Stomach Allow The Practice Of Many Procedures, Including Ng, Og, Tracheal Care And Suctioning, And Insertion, Securing And Care Of Endotracheal Tubes. Arterial Blood Extraction Trainer Specifications Features 1. Palpable Arterial Pulse 2. Realistic Resistance Of Tissue And Artery Wall Felt With The Injection Needle 3. Natural Flashback Training Skills / Applications ● Radial Arterial Puncture ● Artery Blood Sampling ● Radial Line Placement Set Includes: ● 1 Wrist And Hand Model ● 1 Circulation Pump ● 2 Sets Of Puncture Skins (inner And Outer Skin) ● 4 Artery Tubes ● 1 Silicon Tape ● 1 Jar Of Coloring Powder (red) ● 1 Spoon ● 2 Plastic Jars ● 2 Connection Tubes ● 1 Vinyl Sheet ● 1 Syringe ● 1 Storage Case ● 1 Instruction Manual 3d Printer With Basic Materials Specifications ● Print Technology: Fusion Deposition Modeling (fdm) ● Composites-capable 3d Printer W/ Cc Core (high-strength Glass And Carbon Fiber Filament) ● Compatible With Metal 3d Printing Filament 316l / 17-4ph Material And Over 40+ Different Engineering Materials ● Large Build Volume: At Least 330 X 240 X 300 Mm (13 X 9.4 X 11.8 Inches) ● Compatible With Down To 20 Micron (0.001 Inch) Layer Resolution ● Print Head: Dual Extrusion Print Head With A Unique Auto-nozzle Lifting System And Swappable Print Cores ● Capable To Utilize Aa Print Core ● Technology Nozzle Type ● Bb Print Core Technology For Dissolvable Support Nozzle Type ● Cc Print Core For Composites And Abrasive Materials ● Print Head Compatibility ○ Aa Print Core - Build Material ○ Bb- Print Core - Support Material ○ Cc Print Core - Composite Material ● Materials: Compatible With 190+ Different Materials ● Integrated Air Manager ● Air Extraction Rate: 1 - 50 M3/h (35m3/h Nominal Rate For Most Materials At 23°c) ● Osite Material Speed And Precision: ● Print Speed: Min. 30- Max. 300mm/s ● Travel Speed: Min. 30- Max. 350mm/s Up To 16mm3/s ● Precision: 12.5/12.5/5 Micron ● Nozzle Options: 0.25mm / 0.4mm / 0.6mm / 0.8mm Diameter ● Print Surface: Pei Printing Surface ● Inductive Sensor: Yes ● Build Plate: Flexible ● Heatup Time: <2mins ● Auto Detection Of Materials Thru Nfc Technology Material Input ● Sound Operation Level: >51dba ● Built-in Live 1080p Camera ● Includes Software ● Future Proof Investment ● Automatic Materials Switching ● Materials Capacity: Up To Six Spools ● Materials Loading: Front Loading Connection ● File Types: Stl/obj/dae/amf ● Os Requirement: Windows/mac/ubuntu Linux ● Electrical: 100-240vac; 50-60hz ● Open Filament System – Print With Any 2.85 Mm Material ● Connectivity: Wifi, Ethernet, Lan, Usb Drive Connectivity ● 4.7-inch Touchscreen Interface ● Bowden Driven Extruder Technology ● Ruby-tipped Nozzle Option Available Inclusions: ● 3d Printer ● 1 Spool Of Tough Pla Filament And 1 Spool Of Pva (dissolvable) ● Heated Glass Bed ● Front Glass Enclosure ● Usb Thumb Drive, Calibration Card ● Maintenance Tools ● Nfc Spool Holder ● 2x Print Core Aa ● 1x Print Core Bb (for Pva Supports) ● Software With Unending Enterprise Software Subscription And Access To E-learning Modules ● Materials Station ○ Includes 6 Material Storage Equipped With Pre-feeders Which Automatically Swap Between Filaments During Run Outs. ○ Condition Filaments To Optimal Quality And Acts As A Dry-box ● 2 Units Of Filaments Dryer Storage Box ● 3 Units Of Filaments Storage Box ● 1 Unit Of 114l Filament Dry-box ● Speed Kit Bundle With: ○ 2x 0.8 Mm Aa Print Cores For Build Materials ○ 2x 0.8 Mm Bb Print Cores For Support Material Pva Removal Station Specifications Removal Station That Dissolves Support Material Of Prints Quickly And Effectively. ● Container Volume 13.7 Liters ● Maximum Part Size That Can Be Dissolved W 200 X D 230 X H 165 Mm (w 7.8 X D 9 X H 6.4 In) ● Supported Materials: Pla And Pva, Petg, Tough Pla, Nylon, Or Cpe In Combination With Pva ● Supported Solvents: Water ● Rotor Speed: 225 Rpm (normal), 100 Rpm (low) Physical Dimensions At Least W 303 X D 325 X H 374 Mm (w 11.9 X H 12.8 X D 14.7 In) Net Weight At Least 6.35 Kg (14 Lbs) Container Weight (when Empty) At Least 4.2 Kg (9.3 Lbs) Electrical Requirements Voltage: 100 - 240 V Ac Frequency: 50 - 60 Hz Power: 38 W Filaments Starter Bundle Specifications Filaments Starter Bundle Including: ● 5 Units Of Pla ● 5 Units Of Tough Pla ● 5 Units Of Petg ● 5 Units Of Pva ● 3 Units Of Breakaway Infant Warmer Specifications ● Pre-warm Mode Control, Manual Mode Control And Baby Mode Controlled By Micro-computer; ● Set Temperature And Baby Temperature Can Be Displayed Separately; ● Horizon Angle Of Heater Head And Inclination Of The Bassinet Can Be Adjusted; ● The Panels Around Bassinet Can Be Turned Outward; ● X-ray Cassette Under The Bassinet. ● With Wheels And Wheel Breaks ● 1 Unit Only.
Closing Soon25 Nov 2024
Tender AmountPHP 16.9 Million (USD 288 K)
Municipality Of Carmen, Bohol Tender
Automobiles and Auto Parts
Philippines
Details: Description 1 Land Ambulance (type 1) 1 Unit I. Vehicle Specifications And Requirements · Vehicle Type: Four-wheel Passenger Van With 4 Doors (2 At The Front For The Driver And Passenger, One Sliding Door Or Barn Door At The Right Side And Tailgate Or Barn Door At The Rear) · Wheelbase: At Least 2,500-2,800 Mm · Drive Type: Rear Wheel Drive · Engine Size/displacement: 2,500 To 3,000 Cc · Engine Type: 4 Cylinders, In-line Type, 16 Valves, Double Over Head Cam (dohc), Maximum 3,400 Rpm · Alternator And Battery The Capacity Of The Alternator And Battery Must Be Sufficient To Supply The Additional Load Demands Of All Medical Equipment. The Amperage Capacity Of The Alternator Must Be At Least 110 Amperes. · Fuel-injector System: Direct Injection · Emission Compliance: Euro 4 · Fuel Type: Diesel · Fuel Tank Capacity: At Least 65 Liters · Transmission: Manual With At Least Five (5) Speed + One (1) Reverse · Steering: Left Hand Drive With Power-steering System · Brakes: Ventilated Disk On The Front And Ventilated Disk Or Drum Type On The Rear. With Anti-lock Braking System. With Parking Brake · Front Suspensions: Mcpherson Strut Or Double Wishbone Or Torsion Bar With Stabilizer · Rear Suspensions: Rigid Axle With Leaf Spring And Double Acting Shock Absorbers · Wheels: At Least 15 Inch, Aluminum Mag Wheels Or Steel Wheels With Full Cover · Tires: Radial Type And At Least 195 Mm Tire Width Standard Vehicle Lamps: Head Lamps, Tail Lamps, Stop Lamps, Signal Lamps, License Plate Lamps, Fog Lamps And Step Lamps · Vehicle Body Color: White · Floor Material: Metal With Anti-static Floor Matting. Each Entry Point Of The Patient Compartment Must Be Fitted With A Diamond Tread Plate Flooring. · Standard Dashboard Instrumentations: Speedometer, Odometer, Fuel Gauge, Digital Clock, Warning Lamps For Low Oil Pressure, Cooling Water Level, Overheating, Low Battery Charge, Indicator Lamps For Parking Brake And Head Light High-beam, Engine Check, Door Open. · Dashboard And Rear-view Camera System: Resolution Of At Least 1920x1080@30fps, Angle Of View At Least 120 Degrees Diagonal, At Least 2 Inch Led Display, Minimum Storage Capacity Of 64gb, With Loop Recording, Automatic On/off And Night Vision Recording In Low Light. The Cameras Must Be Permanently Installed On The Dashboard Or Windshield And At The Rear Part Of Vehicle. Rear-view Camera Must Be Have Color-coded Parking Grid Features. The Power Supply Must Be From The Vehicle Battery. · Standard Driver’s Cabin Accessories: Am/fm Radio With Speakers, Usb Connector, Front Personal Lamp For Driver And Passenger, Rear View Mirror, Sun Visor And Assist Grips For The Driver And Passenger. · Vehicle Doors Glass Windows: Central Or Power Door Locking System. Hydraulic / Electric Windows For Driver And Front Passenger Sides. The Vehicle Glass Windows (except The Windshield) Must Be Installed With Medium Shade (35% Visible Light Transmitted) Glass Tint. · Windshield Wipers: With At Least Three (3) Speed Intermittent With Washer · Air Conditioning System: Dual Type; At The Driver’s Cabin And At The Patient Compartment With Independent Controls. · Seat Belts: 3 Point Emergency Locking Retractor (elr) Seatbelts For The Driver And Front Passenger. · Airbags: Supplemental Restraint System (srs) Airbags For The Driver And For The Front Passenger. · Driver And Passenger Side Mirrors: Standard Convex Type, Manual Or Power Adjustment · Vehicle Interior Trim: Moulded Trim. The Ceiling Must Be Provided With Insulation. · Stainless Steel Plate On The Rear Bumper To Protect The Bumper When The Ambulance Stretcher Is Being Loaded To The Ambulance. · Set Of Tools: Hydraulic Jack, Tire Wrench, Flat And Philips Screw Drivers, Set Of Pliers, Adjustable Wrench, Early Warning Device And Spare Wheel And Tire. Ii. Emergency Lights, Sirens And Public Address System · Emergency Lights: Roof Mounted Light Bar With Red And Green Flashing Led Lights. The Length Of The Light Bar Must Be The Same As The Width Of The Vehicle Roof. Electric Siren And Public Address System: Standard Ambulance Siren Tones (horn, Manual, Wail, Yelp, Phaser, Hilo/two Tone) And With At Least Two 100 Watts Amplifier And Siren Speakers. With Rotary Switch And Momentary Push-button Override Control. Public Address Override With Attached Microphone And Volume Control Knob · Red And Green Flashing Led Lights Mounted On The Upper Part Of The Rear Of The Ambulance · Red And Green Led Flashing Lights Mounted On The Front Grill Of The Ambulance Iii. Ambulance Body Marking · The Front Of The Ambulance Shall Be Marked With A Reflectorized And Capitalized Word “ambulance” Which Is Spelled Out In Reverse (mirror Image). The Height Of Each Letter Shall Be No Less Than 10 Centimeters And The Word Shall Be Seen At Least Six (6) Meters Away. · Each Side Of The Ambulance Body Shall Have The Capitalized Word “ambulance” Not Less Than 15 Cm In Height And The Letters Must Be In Red Color. · The Rear Side Of The Ambulance Body Shall Be Marked With A Reflectorized And Capitalized Word “ambulance” Not Less Than 15 Cm In Height And The Letters Must Be In Red Color. · The Prescribed Doh Logo With A Diameter Of Not Less Than 36 Cm Shall Be Placed On The Driver’s Door And On The Front Passenger Door. Iv. Patient Compartment · Compartment Interior Height: At Least 1600mm · Compartment Interior Width: At Least 1500mm · Partition Between The Driver And Patient Compartment: Air Tight Bulkhead Made Of Non-porous Material With A Transparent And Shatter-proof Sliding Window At Least 35 Cm X 30 Cm. · Storage Cabinet For Medicines, Instruments And Medical Equipment > Built-in Cabinet Made Of White Painted Aluminum Panels Or Other Lightweight, Equivalent Strength Material Such As Fiberglass, Composites And Fiberglass Reinforced Plastics. The Cabinet Must Be Mounted On The Upper Left Side Of The Patient Compartment And Must Be At Least 200 Cm But Must Not Be More Than 210 Cm In Length. The Cabinet Must Be Firmly Anchored (bolted Or Welded) To Tapping Plates Of The Body Structure. > The Cabinet Must Have Transparent And Shatter-proof Sliding Doors With Low Profile Handles. The Sliding Doors Must Be Easily Opened But Must Not Open During Transit. The Sliding Doors Must Be Fitted With Automatic Latch Or Friction Holding Device. > The Cabinet Must Have At Least 4 Shelves With At Least One Shelf Designed To Fit And Carry Heavy Medical Equipment Such As The Defibrillator And Nebulizer. The Shelves Must Have A Depth At Least 30 Cm But Must Not Be More Than 50 Cm. · Compartment For The Folding Stretcher And Scoop Stretcher: Installed Below The Storage Cabinet, Made Of White Painted Aluminum Panels Or Other Lightweight, Equivalent Strength Material Such As Fiberglass, Composites And Fiberglass Reinforced Plastics. The Compartment Must Be At Least 200 Cm But Must Not Be More Than 210 Cm In Length. The Cabinet Must Be Firmly Anchored (bolted Or Welded) To Tapping Plates Of The Body Structure. Bench For Medical Personnel: The Ambulance Must Be Fitted With 3-seater Bench Permanently Mounted On The Ambulance Floor; One On The Head Side Of The Patient And One On The Right Side Of The Patient Compartment. The Bench (seat And Backrest) Must Be Made Of Sturdy Aluminum Frame And Panels Coated With White Color Paint Or Other Lightweight, Equivalent Strength Material Such As Fiberglass Reinforced · Plastics Or Plastic Laminated. The Seat And Backrest Must Be Fitted With Mattress Made Of Polyurethane Foam Covered With A Washable Leatherette Material. The Construction Of The Bench Must Be In Such A Way That The Underneath Can Be Used As A Compartment. The Bench Must Have A 2 Point Seatbelt For Each Person. > Overhead Lighting: At Least 2 Led White Lights With Low Light Option > Grab Rail: Aluminum Or Stainless Steel Grab Rail At Least 120 Cm Long, 10 Cm Depth (maximum) Installed On The Ceiling Right Above The Patient/ambulance Stretcher. > 220v Ac Supply: The Patient Compartment Must Be Installed With An Electronic Inverter With A Capacity Of At Least 3kva And An Output Voltage Of 220v, 60 Hz. At Least Five (5) Convenience Outlets Must Be Installed At The Different Points On The Compartment To Supply Power To The Medical Equipment. > Intercom System: Intra-vehicle Intercom System Must Be Fitted To Serve As Voice Communication Between The Driver And Personnel In The Patient Compartment. V. Communication Equipment Two (2) Pieces Cellular Phones (one For The Ambulance And One For The Hospital/base). The Cellular Phones Must Be 4g Network Capable, With Internal Memory Of At Least 64gb And 4gb Ram Smartphones. The Phones Must Be Provided With Sim Cards And Battery Charger. Vi. Medical Equipment And Instruments · Ambulance Stretcher > Length: 180 – 185 Cm > Width: 48 – 55 Cm > Loading Height Should Match The Vehicle Floor Height > Loading Capacity: At Least 175 Kg > Materials: Stainless Steel, High Grade Aluminum Alloy > Head Part Rising Angle: At Least 75° Knee Part Rising Angle: At Least 15° > With Collapsible Side Rails And Quick Release Patient Restrain System > With Durable Folding Leg Mechanism > The Mattress Must Be Made Of High-density Polyester Fiber Foam With A Thickness Of At Least 5 Cm And Covered With Waterproof Vinyl Material. > Wheels: 200 - 210mm Diameter, Fixed Front With Locking Brakes And Auto-directional Rear And With 50-55 Cm Loading Carriage Wheels > Loading Rail Mounted In The Ambulance With Latching System > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment. · Automatic External Defibrillator (aed) > Compact, Lightweight, Easy To Use, Bi-phasic Defibrillator With Manual (with Easy 1-2-3 Operation) > Waveform: Rectilinear Biphasic > Defibrillator Charge Hold Time: Not More Than 30 Seconds > Patient Safety: All Patient Connections Are Electrically Isolated > Charge Time: Less Than 10 Seconds With New Battery Charge To 200j With A Fully-charged Battery > Battery Operated > Self-test: Configurable Automatic Self-test When Device Is Turned-on > Monthly Full-energy Test (200j) > Automatic Self-test Checks: > Battery Capacity > Electrode Connection > Electrocardiogram And Discharge Circuits > Microprocessor Hardware And Software > Cpr Circuitry And Cpr-d Sensor And Audio Circuitry > Cpr: Metronome Rate (variable 60 To 100 Cpm) > Defibrillator Advisory: Evaluates Electrode Connection And Patient Ecg To Determine If Defibrillation Is Required > Shockable Rhythms: > Ventricular Fibrillation With Average Amplitude Of > 100 Microvolts > Wide Complex Ventricular Tachycardia With Rated Greater Than 150 Bpm For Adults And 200 Bpm For Pediatrics > Patient Impedance Measurement Range: At Least 0 To 300 Ohms > Defibrillator: Protected Ecg Circuitry > Display Format: Optional Lcd With Moving Bar > Size: Approximately 2.6” X 1.3” > Ecg Viewing Window: At Least 2.6 Seconds > Optional Ecg Display Sweep Speed: Not More Than 25mm/sec; 1”/sec > Data Recording And Storage > At Least 50 Minutes Of Ecg And Cpr Data. > If Audio Recording Is Installed And Enabled, At Least 20 Minutes Of Audio Recording, Ecg And Cpr Data. > If Audio Recording Is Disabled, At Least 7 Hours Of Ecg And Cpr Data. > Pc Minimum Requirements For Configuration And Patient Data Recovery: Windows® 98, Windows® 2000, Windows® Nt, Windows® Xp, Ibm Compatible Pii With 16550 Uart (or Higher) Computer. 64mb Ram. Vga Monitor Or Better. Cd-rom Drive. Irda Port. 2mb Disk Space. > Available With Pediatric Pacing Cable And Pads Synchronized And Direct Defibrillation > Biphasic Energy Waveform, Adjustable Output, From Approximately 1 Up To 200 Joules > Load Compensation Circuit Allows Precise Delivery Of Selected Energy, Based On Patient’s Impedance > Energy Selection > Charge Controls - Push-button Controls On Front Panel > Charge Time - Less Than 10 Seconds With New Battery Charge To 200j With A Fully-charged Battery > Charge/ready Is Indicated Via Audiovisual > Defibrillator Energy - Approximately ±15% At 50ω > Accuracy - Approximately ±30% Over The Range Of 25 To 100 Ω > Defibrillator Waveform - 5ms Monophasic Pulse Display Shows Ecg, Heart Rate, Battery Status And Energy Output Pre-set > Monitor Display Size: Bright Back-lit Alphanumeric Lcd, Approximately 10 X 6 Cm > Frequency Response: Non-diagnostic > Heart Rate Meter: Three-digit Readout Displays Rates From 20 To 300 Bpm > Heart Rate Alarm: User Selectable Alarm Limits > Self-test Is Performed Each Time The Device Is Switched On > System Reports, With Audiovisual Alert: Status, Operation, Malfunctions And Low Battery > Internal Safety Discharge Upon 40seconds Non-delivery Of Accumulated Energy, Switch-off And Technical Failure > Sensitivity, Adjustable 5, 10 And 20mm/mv Pads: > Shelf Life: 5 Years > Conductive Gel: Polymer Hydrogel > Conductive Element: Tin > Packaging: Multilayer Foil Laminate Pouch > Impedance Class: Low > Cable Length: At Least 36 In (91 Cm) > Sternum: Length: At Least 6.1 In (15.5 Cm); Width: At Least 5.0 In (12.7 Cm); Length, Conductive Gel: At Least 3.5 In (8.9 Cm); Width, Conductive Gel: At Least 3.5 In (8.9 Cm); Area, Conductive Gel: At Least 12.3 Sq In (79.0 Sq Cm) > Apex: Length: At Least 6.1 In (15.5 Cm); Width: At Least 5.6 In (14.1 Cm); Length, Conductive Gel: At Least 3.5 In (8.9 Cm); Width, Conductive Gel: At Least 3.5 In (8.9 Cm); Area, Conductive Gel: At Least 12.3 Sq In (79.0 Sq Cm) > Complete Assembly: Folded Length: At Least 7.6 In (19.4 Cm); Folded Width: At Least 7.0 In (17.8 Cm); Folded Height: At Least 1.5 In (3.8 Cm) > Design Standards: Meets Applicable Requirements Of Ansi/aami/iso Df-39-1993. > Shock Resistant Housing Allows System To Function In Demanding Environment > Integrated Carry Handle Facilitates Transport > Splash-resistant Alphanumeric Function Keys Power Supply: > User Replaceable Battery Is Removable/replaceable By The Operator. (10 Type 123a Photo Flash Lithium Manganese Dioxide Batteries. > Battery Capacity: Typical New (20°c) = 5 Years (at Least 225 Shocks) Or At Least 13 Hours Continuous Monitoring. End Of Life Designated By Red X (typical Remaining = At Least 9 Shocks). Battery Compartment To Be Clearly Labeled, Splash-proof And Requiring Tool For Opening For Battery Replacement > Electrical Source Requirements: Battery Operated > Operating Temperature: 32° To 122°f; 0° To 50°c > Storage Temperature: -22° To 140°f; -30° To 60°c > Humidity: 10 To 95% Relative Humidity, Non-condensing > Vibration: Mil Std. 810f, Min. Helicopter Test > Shock: Iec 68-2-27; 100g > Altitude: 300 To 15,000 Ft.; -91m To 4573m > Particle And Water Ingress: Ip-55. > Defibrillator Pads (self- Adhesive, Disposable And Non-polarized) At Least Five (5) Pairs For Adult And At Least Five (5) Pairs For Pedia Ø Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment. · Nebulizer > Portable, Compressor-driven Nebulizer Pump, And A Four-pole Single Phase Motor Design In Metal Frame Construction > Easy To Operate With Sturdy Design For Use In Demanding Environment > Cup Capacity Minimum 3ml To Maximum 10ml > Nebulization, Approximately 0.1 To 0.2ml/minute > Residual Volume Maximum 2ml > Flow Delivery Range (under Load) 0.5 To Maximum 12 Liters/minute Or Greater > Median Mass Aerodynamic Diameter (mmad) Of Particles 0.5 To 4 Microns > Operating Temperature Range 5 To 50 ⁰c > Operating Relative Humidity Range Up To 65% > Compressor Requires No Maintenance And Delivers Oil-free Flow Diaphragm Type And Maximum Compressor Pressure Of 30 Psig Or Greater > Device, With Carry Handle, Is Provided With Accessory Storage Compartment > Power Supply, 220v/60hz > Power Consumption, Approximately 90w > System Configuration Accessories, Spares And Consumables: · System As Specified · Nebulizer Atomizer Body Piece (dome) · Reusable Mouth Piece, Pediatric Size (fitting Atomizer Body Piece) · Reusable Mouth Piece, Adult Size (fitting Atomizer Body Piece) · Air Tubing, Diameter Approximately 6/9mm (inner/outer), Length Approximately 1 Meter · Dosage Cup · Reusable Mask, Size Pediatric · Reusable Mask, Size Adult · Spare Inlet Filters · Spare Particle Filters · Set Of Spare Fuses · Portable Suction Machine > Electrical Suction Pump Supporting Medical Interventions Such As Resuscitation Or Minor Surgery > With Graduated Plastic Jar Auto-clavable, Capacity 1.2 Liters > Jar Is Covered And Fit With Overflow Valve And Antibacterial Filter > Suction Flow Maximum, Approximately 17l/minute > Vacuum Adjustable From 0 To Approximately - 600mmhg > Vacuum Control Button And On/off-switch > Sturdy Shock Resistant Casing, Easy To Carry And Easy Clean > Silent Operation Supplied With: > 2 X Set Of Silicone Tubes, Diameter 8/14mm (inner / Outer), Length Approximately 2.5m > 2 X Bi-conical Connectors Fitting The Silicone Tubes > 1 X Spare Jar Of 1l With Cover, Gasket And Overflow Valve > 1 X Set Of Spare Antibacterial Filters > 1 X Set Of Spare Fuses > 1 X Instructions For Assembly, Use And Maintenance, And List Of Accessories And Spare Parts With Product Reference Code In English Language > Consumables Should Be Available In The Local Market Power Supply > Power Input To Be 220-240vac (single Phase) / 60hz As Appropriate Fitted With Philippine Standard Plug > Voltage Corrector/stabilizer Of Appropriate Ratings Meeting Philippines Standard Specifications (input 160-260 V And Output 220-240 V And 60 Hz) > Power Consumption Approximately 50 Watts > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Examining Light (mounted On The Head Side Of The Patient) > Mobile Examination Light, Sturdy Construction. > On Heavy Base With 5 Swivel Castors, 2 With Brakes. Low Center Of Gravity For Optimal Stability And Reach > Single Lamp With Led Bulb: White Led Approximately 50,000 Hours Life > Field-of-view Diameter, Approximately 0.15 M At Working Distance > Homogeneous Illumination Across Entire Field-of-view, Approximately 20,000 Lux At 30.5 Cm To 50 Cm Working Distance > Color Temperature, Approximately 5500⁰k > Light Head Mounted On Spring Loaded Articulating Arm, Height Approximately 1.50 M > Touch Less On/off Switch And Electronic Control Box Incorporated In Base Or Spring Loaded Articulating Arm Power Supply: > -power Input To Be 220 Vac (single Phase) / 60hz As Appropriate Fitted With > Philippine Standard Plug > -power Consumption, Approximately 35 Watts Dimensions: > -weight: Total Mobile Stand: Approximately 5.78 Kg. > -height: Total Mobile Stand: Approximately 150.0 Cm (including Luminaire And Control Box) > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Aneroid Sphygmomanometer (mounted On The Ambulance Wall On The Head Side Of The Patient) > The Sphygmomanometer Is Composed Of Cloth Cuff Containing An Inflatable Bag (adult-25 Cm To 35 Cm) > Connected Via A Tube To A Flexible Bulb With Valve And Integrated Manometer Needle Gauge. > Latex And Mercury Free. > Bp Cuffs Are Anti-microbial Treated. > The Adult (25 Cm To 35 Cm) Cuff With Double Velcro Fastening, Enabling It To Be Adjusted To Fit Tightly > Around The Arm. > The Cuff Is Washable, Very Strong And Reinforced At Both Ends. > The Bag Is Inflated By Means Of The Flexible Bulb Connected Via A Tube (length Approximately 60 Cm, > Flexible And With Reliable Quick Connector) > The Quick Connector Can Easily Be Connected To All Types Of Inflation Bulbs > Inflation Bulb With Integrated Manometer Needle Gauge > Dial Graduated Up To 300 Mmhg Aneroid Instrument Mounted At A 20º Angle For Ease Of Viewing Clinical Sphygmomanometer For Desk Type, With Pressure Release Valve > Pressure Gauge To Allow Reading Of Pressure To 2mmhg Accuracy > Gauge Body To Allow Recalibration Of Readings, Yet In Normal Operation Be Sealed And Secure > Plastic Manometer With Chrome Plated Steel Bracket > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Folding Stretcher > Length: At Least 1900 Mm > Width: At Least 530 Mm > Loading Capacity: At Least 120 Kg > The Stretcher Must Have A Quick Release Patient Restrain System > Frame Material: High Grade Aluminum > Frame Must Be Made Of Sturdy Lightweight, Non-twisting Construction And With Rubber Handles > Stretcher Bed Material Must Be Washable > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Scoop Stretcher > Length: At Least 200 Cm > Adjustable Length > Width: At Least 42 Cm > Loading Capacity: At Least 150 Kg > The Stretcher Must Have At Least Three (3) Quick Release Patient Restrain System > Frame Material: High Grade Aluminum > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Heavy Duty Stethoscopes (dual) > Easy To Dismantle, Clean, And Disinfect. > Double Cup, Dual-use (adult And Pediatric Auscultation) In Stainless Steel Or Chromed Brass. > Adult Diaphragm: Approximately 43mm > Bell Diameter: Approximately 32mm > Y Tube Treated Rubber With Large Diameter: Approximately 10 Mm > Arms: Stainless Steel Or Chrome Brass Or Aerospace Alloy, With Spring Treated To Give Lasting Spring And Maximum Reliability And Comfort. > Removable Plastic/rubber Ear-pieces. > Supplied With Spare Diaphragms Or Diaphragm Membrane, Y Tube And A Pair Of Ear-pieces > Environmental Factors: > The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0 - 50 ⁰c And Relative Humidity Of 15-90%. > The Unit Shall Be Capable Of Operating In Ambient Temperature Of 20-30 ⁰c And Relative Humidity Of Less Than 70%. > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Container Box · Non-contact Thermometer > Measuring Scale: Degree Celsius > Lcd Or Led Display With At Least Three (3) Digit Measurement Display > Components Must Have No Glass And Mercury Materials > Measurement Range: 34°c To 42°c Or Wider Range. > Beep Sound Upon Measurement > Switch Off Automatically When Not In Use. > Battery Operated. > With Low Battery Indicator > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Blood-glucose Meter With Strip > Hand Held Meter > No Routine Maintenance Reading Range/linearity From 20 To 600 Mg/dl > Maximum Reading Time Of Less Than 10 Seconds > Use Of Electrochemical Technology > Use A Minimum Blood Sample Of Less Than 1.5µl > Lcd Display > Measuring Unit In Mg/dl. > Wide Operating Temperature > A Minimum Memory Of 50 Test Results > Should Have Easy Code Entry Technique > Battery Should Be Replaceable Without Using Any Tools > Should Have Facility To Ensure Accuracy Of Measurements. > Should Be Supplied With Three Types Of Control Solutions Of Each At Least 3 Ml > Item Should Have Data Transfer Facility Through Usb Device Or Blue Tooth > The Unit Should Be Cleanable And Sterilizable With Alcohol · Glucose Strips > Should Be Able To Use Capillary Blood Samples. > Should Have A Minimum 4 Months Shelf Life After Opening The Strip Vial. > All Strips Should Have At Least One Year Expiry Date From The Date Of Supply. > Minimum Of 10 Strips, 10 Lancets, And 1 Lancing Device Should Be Supplied Along With The Equipment. > Strips Should Be Available In The Local Market. Power Requirements > Shall Be Battery Operated 3-volt Lithium Ion Cell Battery Or 2 X (aaa) Alkaline Battery. Battery Should Be Supplied With Item And Should Last At Least 1000 Tests. > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Manual Resuscitators For Adult > Resuscitator To Ventilate Adult (body Weight Over 30kg) > Resuscitator Operated By Hand > Ventilation With Ambient Air > Resuscitator Shall Be Easy, To Disassemble And Reassemble, To Clean And Disinfect, And Be Autoclavable. > All Parts Must Be Manufactured From High-strength, Long-life Materials And Require No Special Maintenance Or Storage Conditions. Resuscitator Shall Be Supplied As A Complete Set With: > Compressible Self-refilling Ventilation Bag, Capacity: 1500-2000 Ml > Non-rebreathing Patient Valve With Or Without Pressure Limiting Valve, Patient Connector Outside/inside Diameter (od/id): 22/15 Mm > Inlet Valve With Nipple For 02 Tubing > Oxygen Reservoir Bag Complete, Capacity: 2000-2600 Ml > Masks, Transparent, In 3 Sizes: > 1 Mask, Face Shape Type, Size Adult Small/teenager > 1 Mask, Face Shape Type, Size Adult Medium > 1 Mask, Face Shape Type, Size Adult Large Resuscitator Supplied In A Box As A Complete Set, With Clear Instructions / Diagrams For Use Covering The Technical Performances, The Use And The Maintenance Of The Resuscitator And Assembly In English Language > Materials: Latex-free > Compressible Self-refilling Ventilation Bag: Silicone Rubber, > Non-rebreathing Patient Valve With Pressure Limiting Valve: Polycarbonate/polysulfone/silicone, > Inlet Valve With Nipple For O2 Tubing: Polycarbonate/polysulfone/silicone, > Oxygen Reservoir Bag: Plastic > Masks: Transparent Silicone Rubber. Standards, Safety And Training: > Should Be Fda, Ce, And Ul Approved Product > Conforming To International Standards: Iso, Ce Certification, Fda > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment Or Container · Manual Resuscitators For Neonate/infant > Resuscitator To Ventilate Preterm, Newborn, Small Infant (body Weight 0-7 Kg) > Resuscitator Operated By Hand > Ventilation With Ambient Air > Resuscitator Shall Be Easy, To Disassemble And Reassemble, To Clean And Disinfect, And Be Autoclavable. > All Parts Must Be Manufactured From High-strength, Long-life Materials And Require No Special Maintenance Or Storage Conditions. Resuscitator Shall Be Supplied As A Complete Set With: > Compressible Self-refilling Ventilation Bag, Capacity: 200-250ml > Non-rebreathing Patient Valve With Pressure Limiting Valve, 40± 5 Cmh2o, Patient Connector Outside/inside Diameter (od/id): 22/15mm, > Inlet Valve With Nipple For 02 Tubing > Masks, Transparent, In 3 Sizes: > 1 Mask, One Piece, Round Shape Type, Size Preterm > 1 Mask, One Piece, Round Shape Type, Size Newborn > 1 Mask, One Piece, Round Shape Type, Size Infant Small > Resuscitator Supplied In A Box As A Complete Set, With Clear Instructions / Diagrams For Use Covering The Technical Performances, The Use And The Maintenance Of The Resuscitator And Assembly In English Language > Materials: Latex-free > Compressible Self-refilling Ventilation Bag: Silicone Rubber > Non-rebreathing Patient Valve With Pressure Limiting Valve: Polycarbonate/polysulfone/silicone > Inlet Valve With Nipple For O2 Tubing: Polycarbonate/polysulfone/silicone > Masks: Transparent Silicone Rubber Standards, Safety And Training: > Should Be Fda, Ce, And Ul Approved Product > Conforming To International Standards: Iso, Ce Certification, Fda Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment Or Container Manual Resuscitators For Pedia (child) > Resuscitator To Ventilate Child (body Weight 7-30 Kg) > Resuscitator Operated By Hand > Ventilation With Ambient Air > Resuscitator Shall Be Easy, To Disassemble And Reassemble, To Clean And Disinfect, And Be Autoclavable. > All Parts Must Be Manufactured From High-strength, Long-life Materials And Require No Special Maintenance Or Storage Conditions. > Compressible Self-refilling Ventilation Bag, Capacity: 500-700 Ml > Non-rebreathing Patient Valve With Pressure Limiting Valve, 40 ±5 Cmh2o, Patient Connector Outside/inside Diameter (od/id): 22/15 Mm > Inlet Valve With Nipple For 02 Tubing > Oxygen Reservoir Bag Complete, Capacity: 2000-2600 Ml > Masks, Transparent, In 3 Sizes: · 1 Mask, Round Shape Type, Size Child Small · 1 Mask, Round Shape Type, Size Child Medium · 1 Mask, Face Shape Type, Size Child Large > Resuscitator Supplied In A Box As A Complete Set, With Clear Instructions / Diagrams For Use Covering The Technical Performances, The Use And The Maintenance Of The Resuscitator And Assembly In English Language > Materials: Latex-free > Compressible Self-refilling Ventilation Bag: Silicone Rubber > Non-rebreathing Patient Valve With Pressure Limiting Valve: Polycarbonate/polysulfone/silicone, > Inlet Valve With Nipple For O2 Tubing: Polycarbonate/polysulfone/silicone, > Oxygen Reservoir Bag: Plastic > Masks: Transparent Silicone Rubber · Oxygen Cylinder With Oxygen Therapy Set > At Least 20 Pounds Capacity > Must Be Color Green > Oxygen Therapy Set · Gauge Reading: 1,800 Psi Or Higher · Flowmeter: 0 To 15 Li/min · Humidifier Bottle: Hard Plastic, Capacity: 200ml To 300ml · Accessories: Mouth Piece, Tubing, Open Wrench For Installing The Therapy Set To The Cylinder · The Cylinder Must Be Placed In A Holder Mounted On The Head Side Of The Patient · Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Equipment · Laryngoscopes Set > Constituted Of A Large Hollow, Cylindrical, Slightly Ribbed Handle And A Set Tongue Depressor In Fiber Optic. > The Handle Is Made Of Fiber Optic Led Light > The Handle Can Be Opened At One End To Insert Two Type C Alkaline Battery > The Other End Has A Stud Contact Which Fits The Various Sizes And Types Of Depressors > The Set Of Autoclavable Depressors Includes: A. 4 Curved Depressors, Macintosh Type: No. 1: Approximately 66 Mm Length No. 2: Approximately 85 Mm Length No. 3: Approximately 105 Mm Length No. 4: Approximately 140 Mm Length B. 5 Straight Depressors, Miller Type: No. 0: Approximately 56 Mm No. 1: Approximately 82 Mm No. 2: Approximately 135 Mm No. 3: Approximately 175 Mm No. 4: Approximately 185 Mm > Contained In Suitable Protective Plastic Box Or Vinyl Sturdy Padding Case > Battery Compartment (if Reusable) To Be Sealed Against Liquid Ingress, Yet Easily Opened > On/off Switch To Be Robust And Easy To Use > Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Container Box · Immobilization Devices A) Cervical Collars I. Rigid For Children Ages 2 Years Or Older Ii. Child And Adult Sizes (small, Medium, Large) B) Head Immobilization Device (not Sand Bags): Firm Padding Or Commercial Device C) Lower Extremity (femur) Traction Devices I. Limb-support Slings Ii. Padded Ankle Hitch Iii. Padded Pelvic Support Iv. Traction Strap (adult & Child Sizes) D) Upper And Lower Extremity Immobilization Devices I. Joint-above And Joint-below Fracture (sizes Appropriate For Adults And Children) Ii. Rigid- Support Constructed With Appropriate Material (cardboard, Metal, Pneumatic, Vacuum, Wood Or Plastic) – Various Sizes E) At Least 2 Pieces - Resistant Straps Or Cravats · Delivery Set All Instruments Must Be Surgical Grade Stainless Steel Material With ± 0.4 Inch Measurement Tolerance > 1 Pc. Sponge Holding Forceps, Rampley 9.5" > 1 Pc. Kidney Dish 10" > 1 Pc. Bowl 200mm > 1 Pc. Umbilical Scissors, American, Straight 4.5" > 1 Pc. Needle Holder Mayo Hegar Straight 6.5" > 1 Pc. Episiotomy Scissors 14.5 Cm > 1 Pc. Cusco Vaginal Speculum Medium > 1 Pc. Hartmann Mosquito Artery Forceps Straight 120mm > 1 Pc. Metal Catheter > 1 Pc. Uterine Curette > 1 Pc. Treves Dissecting Forceps, Plain, 200mm > 1 Pc. Spencerwells Artery Forceps Curved 6" > 1 Pc. Kocher Artery Forceps, Toothed Straight 6" Non-removable Doh Logo And The Words “for Ambulance Use Only” Must Be Marked On The Visible Part Of The Instrument Container Box. · Patient Monitor > Atleast 10 Inches Color Tft Led Display > 800 X 600 Pixels Resolution > Maximum Display Of 11 Channels; Auto Channel Height Adjustment Function > Lightweight & Ergonomic Design > Parameters: 3/5 Lead Ecg, Hr, Resp, Nbp, Spo2, Pr, Temp > With St Segment Analysis And 21 Calls Of Arrhythmia > Fast Spo2 Technology With Anti-motion And Low Perfusion Performance > Navigation Wheel For Information Input And Screen Navigation > Backlit Function Buttons For Quick Access To Key Functions > Bed-to-bed Overview Function For Up To 32 Monitors Without Central Monitoring System > Bi-directional Communication Via Lan Networking To A Central Monitoring System > Standard Hl7 Output > Fan-less Design To Reduce Dust Deposits > Applications From Neonate To Adult > With Oxycrg & Minitrend > With Big Number Screen, Dynamic Trend Screen, & Ocrg Screen > 4 User-defined Layout > Timing Clock Configurable From 5-30mins > 1,600 Sets Nbp Table > 1,200-hour Trend Graph Of All Parameters (with Data Manager Function) > 120-minute Full Disclosure Ecg 1 Waveform Review (with Data Manager Function) > 200 Sets Alarm Events & 200 Sets Arrhythmia Events > With Drug Calculation > With Hr Variation & Dynamic Blood Pressure Analysis > Rechargeable Lithium Ion Battery With 2.5 Hrs Of Operation > With Built-in 3-channel Recorder > Standard External Interface Available: Ecg Analog Output, Vga Output, Nurse Call, Lan, Usb > Patient Data Export Using A Usb Data Manager > Net Weight: Approximately 4.2kg Vii. Other Equipment And Accessories Note: The Items Below (except The Iv Holder) Must Be Marked With Non-removable Doh Logo And The Words “for Ambulances Use Only” On The Visible Part Of The Equipment. > Fire Extinguisher (rating 2a10bc), Five (5) Pounds, With Holder Mounted On The Ambulance Floor. > Heavy Duty Led Flashlight With At Least 1,000 Lumens Of Brightness With Extra Batteries. Iv Holder (mounted On The Ambulance Wall Head Side Of The Patient). > Digital Clock With At Least 4 Inch Display Mounted On The Ambulance Wall. > Air Purifier With Multi-stage Air Filters (pre-filter, Hepa, Carbon) And With Uv Light. > Garbage Container At Least 3 Liter Capacity And Made Of Fiberglass Reinforced Plastic Or Acrylonitrile Butadiene Styrene (abs) Plastic Material And With Lid Cover. The Container Must Be Properly Labelled And Must Be Mounted On The Ambulance Floor. > Sharps Container With Sliding Lid And At Least 1 Liter Capacity, Made Of Fiberglass Reinforced Plastic Or Abs Plastic Material. The Container Must Be Mounted On The Ambulance Wall. I. Other Requirments To Be Submitted During The Bid Opening 1. Product Brochure(s) Or Technical Data Sheet(s) In Hard And Soft Copies Showing The Technical Specifications Of The Following In English Language: A) Ambulance Vehicle B) Emergency Lights, Siren And Public Address C) Ambulance Stretcher D) Automatic External Defibrillator E) Nebulizer F) Examining Light G) Aneroid Sphygmomanometer H) Folding Stretcher I) Scoop Stretcher J) Heavy Duty Stethoscopes K) Non-contact Thermometer L) Blood Glucose Meter M) Manual Resuscitators N) Suction Machine O) Oxygen Therapy Set P) Laryngoscopes Set Q) Delivery Set R) Air Purifier S) Patient Monitor · Valid Marketing Authorization, Registration Approval Or Free Sale Certificate For The Automatic External Defibrillator Issued By The Health Authority In The Country Of Origin. · Valid Certificate Of Distributorship (as First Tier Distributor) Issued By The Foreign Manufacturers Or Local Distributors Of The Medical Equipment And Instruments Authorizing The Bidder To Sell/distribute Their Products. · Notarized Certificate From The Bidder: That The Brands Of The Medical Equipment And Instruments Have Been In The Local And/or International Market For At Least Ten (10) Years. > That Medical Equipment And Instruments Are Brand New, Unused, Not Discontinued Models And Were Not Subjected To Any Product Recall. · Bidder’s Valid And Current License To Operate (lto) As A Medical Device Distributor Issued By The Philippine Food And Drug Administration. · Valid And Current Certification Of Product Registration (cpr) For The Thermometer, Lancets In The Blood-glucose Meter And Manual Resuscitator Issued By The Philippine Food And Drug Administration (pfda) · Notarized Certificate From The Manufacturer Or Local Dealer Of The Ambulance/vehicle: > That The Manufacturer Has Been Manufacturing Vehicles With Diesel Engines For The Past Twenty Five (25) Years. > That The Ambulance/vehicle Is Brand New, Unused, Not A Discontinued Model And Was Not Subjected To Any Product Recall. · Proofs (such As Sales Invoice) That The Brand Of The Vehicle Has Already Been Sold In The Country As An Ambulance. Requirement/s If Declared The Lowest/single Calculated Bid · Site Inspection To The Bidder’s Facility To Verify/validate The Capability And Capacity Of The Bidder To Fabricate The Ambulances As Well As Sample Unit With Complete Medical Accessories. The Inspection Shall Be Conducted By The Procuring Entity Technical Working Group. This Requirement Is Not Applicable If The Facility Is Located Outside The Philippines. · Motor Vehicle Service Center Should Be Located In Each Province Namely Cebu, Bohol, & Negros Oriental In Order For The Recipient Facility To Have Easy Access During Preventive Maintenance. Requirements If Awarded The Contract · The Supplier Shall Provide Orientation/training On The Use And Maintenance Of The Ambulance, Medical Equipment And Instruments On A Schedule To Be Agreed Upon By Procuring Entity And The Winning Bidder. · The Supplier Shall Submit/provide The Following To The End User: > Operator’s Manual In English Language For The Ambulance, Medical Equipment And Instruments. > Certification Of Inclusive Preventive Maintenance Services From 10 Kilometer Up To 40 Kilometer With An Interval Of 10,000kms Or 6 Months Whichever Comes First At Any Manufacturer’s Service Center Branches In Central Visayas. > Warranty Certificate For Three (3) Years On Parts And Services For The Ambulance. The Manufacturer/dealer Shall Either Repair Or Replace Any Item Or Part In The Ambulance That Is Found To Be Defective In Material Or In Workmanship Under Normal Use. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Testing And Commissioning. The Warranty Certificate Shall Include The Following: · That The Warranty For The Vehicle Shall Not Be Affected In Case A Change Of Dealer Occurs. That If The Ambulance Is Unable To Return To The Service Center During The Warranty Period, The Manufacturer/dealer Shall Provide Mechanics And/or Technicians That Can Perform On-site Service And Maintenance, Provided That The End User Will Shoulder The Travel Expenses. · Warranty Certificate For Two (2) Years On Parts And Services For Medical Equipment, Instruments And Ambulance Accessories. The Supplier Shall Either Repair Or Replace Any Item Or Part In The Said Equipment That Is Found To Be Defective In Material Or In Workmanship Under Normal Use. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Testing And Commissioning. The Warranty Certificate Shall Include The Following: > The Bidder Shall Conduct The Necessary Corrective Maintenance Within Fifteen (15) Calendar Days Upon Notification Of Equipment Breakdown From The End-user. > The Bidder Shall Have The Primary Responsibility And Accountability To Ensure That In Case Of Defects, The Vehicle, Equipment, Instruments And/or Peripherals Are Appropriately Repaired Or Replaced And Shall Be In Good Working Condition Thereafter. · At Least Three (3) Years Validity Of The Vehicle From Land Transportation Office Region 7 (lto Ro7) Registration With Red Plate. This Is To Allow Easy Accessibility By The Recipient Lgus For The Processing And Transfer Of The Documents. · Third Party Liability (tpl) Vehicle Insurance For One (1) Year And Comprehensive Gsis Vehicle Insurance For One (1) Year. · Delivery > Delivery Schedule: Within 90 Calendar Days Upon The Receipt Of Purchase Order > Upon Delivery, Each Ambulance Shall Undergo Preliminary Physical Inspection By The Inspection Team Of The Procuring Entity To Ascertain The Physical Condition And Acceptability Of The Units. All Medical Equipment, Instruments, Ambulance Accessories And Peripherals Must Be Functioning And Must Have No Physical Damage. > All Land Ambulance Units Shall Be Filled Up With Crude Diesel At Full Tank Capacity Upon Delivery. · Terms And Conditions: > Supplier Must Not Have Any Pending Or Incomplete Delivery, Installation, Training And Demonstration Beyond The Delivery Period Indicated In The Purchase Order With Any Existing Doh-cvchd Projects. > The Supplier Must Coordinate With The Equipment Unit Head And Supply Officer On The Schedule Of The Delivery, Completion Of Training & Demonstration In Order To Facilitate Inspection Of The Doh Cvchd Inspection Team. Payment Will Only Be Made After Delivery And Installation. > Demonstration, Training & Completion Of The Accessories And Equipment Should Be Within 5 Days After The Delivery Of The Equipment. O *recipient Facility Shall Sign The Ptr Only If The Supplier Fully Complied With The Above The Supplier Shall Conduct Comprehensive Demonstration & Training For Staff And Support Services Till Familiarity With The Unit. A Copy Of The Certificate Of Training And Documentation During The Training Session Shall Be Provided To The End Users And Supply Office.
Closing Date10 Dec 2024
Tender AmountPHP 3 Million (USD 50.8 K)
2301-2310 of 2318 active Tenders