Waterproofing Tenders
Waterproofing Tenders
Indian Army Tender
GEM
India
Closing Soon8 Feb 2025
Tender AmountRefer Documents
Description: CATEGORY: Nails steel wire round assorted , Washer plain steel ,
Washer spring single coil type B steel , Washer spring
tension , Washer spring single coil , Pin cotter split 25 mm ,
Pin cotter split 40 mm , Pin cotter split 80 mm , Pin cotter
split 10 mm , Nails brad cut assorted , Spring washer single
coil type B , Pin split cotter 25 mm , Pin cotter split 50 mm ,
Rivet snap head copper 20 mm , Rivet solid snap head
copper 40 mm , Solder soft grade 5090 Tin , Piping copper
0.8 mm , Tubing seamless copper 12 , Tubing seamless
copper 16 , Flux welding aluminium 110G container , Bronze
450 GM container welding metal rod , Iron caste super
silicon , Welding metal rod copper , Abrasives cloth emery
or corundum IS grit 180 , Abrasives cloth emery or
corundum IS grit 100 , Abb cloth emery grit 50 , Abbrasives
paper glass IS grit 120 , Abrasives paper emery or
corundum IS grit 180 , Abrasives paper emery or corundum
IS 36 , Acid hydrochloric technical , Soap laundry 12cm ,
Adhesive movicol L Fevicol SR 988 , Adhesive syn resin
resin araldite AY 103 tube , Adhesive sealing metal , Paint
RFU finishing air driying syn ena black , Paint RFU finishing
syn ena white , Paint RFU finishing driying syn ena red
oxide , Inhibitor corrosion vapour barrier water soluble ,
Detergent solution general purpose , Cement for brass
aluminium to rubber joint , Adhesive universal 225 gm ,
Graphite flake for lubricant , Tubing rubber internal dia
meter , Tape adhesive transparent waterproof 675 mm ,
Paper wrapping craft 1189 MM , Compound mastic joint
cork sheet thick , Joining asbestos fibre compound graphited
thick 100 100mm , Jointing asbestos fibre compound
graphited , Jointing asbestos fibre compounded graphite ,
Packing asbestos braided yarn core rounded , Packing
asbestos braided yarn core round , Asbestos mill board
thickness , Tapes insulating Inch
Bgis Pwgsc Rp1 Tender
Civil And Construction...+1Civil Works Others
Canada
Closing Soon14 Feb 2025
Tender AmountNA
Details: The Scope Of This Project Includes The Complete Removal And Disposal Of All Existing Hard Surfaces On The Podium, Sidewalk, And Driveway At The Entrance Of The John G. Diefenbaker Building. This Will Be Followed By The Removal And Replacement Of The Waterproofing Membrane Beneath The Podium, Which Is Critical To Addressing Water Infiltration Issues Affecting The Parking Garage Below. Additionally, The Project Will Resolve Drainage And Sloping Problems On The Podium To Prevent Further Water Retention And Direct Water Away From The Building Envelope. Finally, New, Durable Hard Surfaces Will Be Installed On The Podium, Walkway, And Driveway, Restoring Both Functionality And Aesthetic Integrity To These Key Exterior Areas.
Bhabha Atomic Research Centre - BARC Tender
Civil And Construction...+1Civil Works Others
Eprocure
India
Closing Date24 Feb 2025
Tender AmountINR 24.7 Million (USD 285.4 K)
Description: Membrane And Chemical Based Waterproofing On Terraces Of C And D Block Of Mod Labs And Other Buildings, Barc, Trombay, Mumbai.
Transmission Corporation Of Andhra Pradesh Limited - APTRANSCO Tender
Civil And Construction...+1Civil Works Others
India
Closing Soon10 Feb 2025
Tender AmountINR 779.6 K (USD 8.9 K)
Description: Repairs To The Roof Slab & Ceiling With Specialised Waterproofing Treatment To Arrect Water Leakages From Roof Slab Of Control House At 132/33kv Mahabubnagar Sub-station In Mahabubnagar Circle.
Municipality Of Bayambang Pangasinan Tender
Civil And Construction...+1Civil Works Others
Philippines
Closing Soon11 Feb 2025
Tender AmountPHP 1.3 Million (USD 23.7 K)
Details: Description General Specifications Project : Re-routing Of Secondary Electric Line, Internet Cables, Telephone Cables & Cctv Cables, Including Installation Of Emergency Lights & Manual Fire Alarm Bell (phase Ii) Location : Municipal Compound, Zone Ii, Bayambang, Pangasinan Area : 8,579.28 Sq.m These Specifications Are Intended To Cover The Construction Of The Rehabilitation Of Mdrrmo (retrofitting Of Column, Septic Tank, Comfort Rooms, Ceiling, Wall And Electrical Works) As Shown On The Plans And Described In These Specifications. The Entire Work Is To Be Finished In Every Part With A First-class Job To The Full Extent Of The Meaning Of Plans And Specifications. Intent And Application Of The Provisions Of This Section A. The Scope Of Work Covered Within These Specifications Is The Complete Re-routing Of Secondary Electric Line, Internet Cables, Telephone Cables & Cctv Cables, Including Installation Of Emergency Lights & Manual Fire Alarm Bell (phase Ii) Located In Municipal Compound, Zone Ii, Bayambang, Pangasinan. B. This Section Is Prepared In A Concise Manner, The Intention Of Which Is To Save Time And Effort In Locating Important Contents Within These Specifications. C. Execution Of This Section Shall Be Coordinated And Harmonized To Each Corresponding Elaborated Section Of These Same Specifications. D. In Case Discrepancies Exist Between This Section And Its Corresponding Elaborated Sections, Notify The Procuring Entity Immediately For Clarification; Their Decision Shall Be Final. E. The Contractor Shall Bear The Responsibility Of Checking All The Numbers And Units As Indicated In The Bill Of Quantities. It Is Understood That The Contractor Shall Supply And Install The Required Units In Accordance With The Plans And The Specifications. F. In Their Big Proposal, The Bidders May Propose Materials Or Equipment Or Makes Other Than Those Specified In The Boq And/or Specifications, Provided They Are Of Equivalent Specifications And Functionalities. G. During Project Implementation, The Winning Bidder/contractor May Propose Substitution Of Materials Or Equipment Or Makes Other Than Those Specified In The Contract Documents Shall Be Subject To The Approval Of The Procuring Entity For The Following Reasons Only. 1. That The Materials Or Equipment Proposed Substitution Is Equal Or Superior To The Materials Or Equipment Specified In Construction Efficiency And Utility Provided That Any And All Costs Relative Thereof Shall Be Shouldered By The Contractor. 2. Or That The Materials Or Equipment Specified Cannot Be Delivered To The Job Site On Tome To Complete The Work Of The Contractors Due To Conditions Beyond The Control Of The Contractor. 3. In Case Of A Price Difference, The Procuring Entity Shall Receive All Benefits Of The Difference In Cost Involved In Any Substitution And The Contract Shall Be Altered By Change Order To Credit The Procuring Entity With Any Savings So Obtained. H. To Receive Consideration, Request(s) For Substitution Shall Be Accompanied By Documentary Proof Of Equality Or Difference In Price And Delivery, If Any, In The Form Of Certified Quotations And Guaranteed Date Of Delivery From Suppliers Of Either The Proposed Substituted Materials Or Equipment. General Conditions Of Plans And Specifications The Execution Of This Specification, Plans And Other Related Contract Documents Shall Be Subjected To The Rules And Regulations As Provided In The General Conditions Of The Contract. The Plans And Specifications Shall Be Interpreted By The Procuring Entity And Or His/her Representative. The Contractor Is Enjoined To Confer With The Procuring Entity On Items For Clarification Before Submitting His Bid. No Excuses Shall Be Entertained For Misinterpretation Of The Plans And Specifications After The Award Of Contract. All Work As Deemed Required By The Procuring Entity Shall Be Carried Out Properly By The Contractor. A. The Contractor Shall Consult The Procuring Entity On Portion Of The Work Not Mentioned In The Specifications And Not Illustrated On The Plans. He Shall Not Work Without Proper Instruction Or Detailed Plans Approved By The Procuring Entity, Otherwise He Shall Be Responsible For The In Acceptance Of The Work Done Without Details. In Such Case, The Contractor Shall Make Good The Work At His Own Expense. B. No Alteration Or Addition Shall Be Allowed Without The Consent And Proper Documentation Approved By The Procuring Entity, Even Such Change Is Ordered By The Procuring Entity. The Contractor Shall Bring The Case To The Procuring Entity. Request For Approval Of Such Changes, Alteration, Deviation Of Work Shall Not Be Done Without The Consent Of The Procuring Entity. Changes May Be Presented To The Procuring Entity In The Form Of Shop Drawings. Two (2) Sets Of Clean Plans And Specification Shall Always Be Kept At The Jobsite To Be Available To The Procuring Entity Or Their Representative Upon His Request During The Construction. Part D. Electrical Works Item 1100. Conduits, Boxes And Fittings (conduit Works / Conduit Rough-in) Description This Item Shall Consist Of The Furnishing And Installation Of The Complete Conduit Work Consisting Of Electrical Conduits; Conduit Boxes Such As Junction Boxes, Pull Boxes, Utility Boxes, Octagonal And Square Boxes; Conduit Fittings Such As Couplings, Locknuts And Bushings And Other Electrical Materials Needed To Complete The Conduit Roughing-in Work Of This Project. Material Requirements: All Materials Shall Be Brand New And Shall Be Of The Approved Type Meeting All The Requirements Of The Philippine Electrical Code And Bearing The Philippine Standard Agency (psa) Mark. Conduits Conduits Shall Be Standard Rigid Steel, Zinc Coated Or Galvanized. Intermediate Metal Conduit May Be Used If Shown Or Specified On The Approved Plans. Pvc Conduit If Required Shall Be Schedule 40. Enamel Coated Steel Conduits And Conduits With Rough Inner Surfaces Are Not Acceptable. Conduit Boxes All Conduit Boxes Shall Be Code Gauge Steel And Galvanized. Outlet Boxes Shall Be Galvanized Pressed Steel Of Standard Make. In General, Outlet Boxes Shall Be At Least 100 Mm Square Or Octagonal, 53 Mm Deep And 16 Mm Minimum Gauge. Conduit Fittings All Conduit Fittings Such As Locknuts And Bushings Shall Be Galvanized Of Standard Make. Construction Requirements: All Works Throughout Shall Be Executed In The Best Practice In A Workmanlike Manner By Qualified And Experienced Electricians Under The Immediate Supervision Of A Duly Licensed Electrical Engineer. Conduits Conduits Should Be Cut Square With A Hacksaw And Reamed. Bends Shall Be Made With The Required Radius. In Making Bends Only Conduit Bending Apparatus Will Be Used. The Use Of A Pipe Tee Or Vise For Bending Conduits Shall Not Be Permitted. Conduits Which Have Been Crushed, Deformed Or Flattened Shall Not Be Installed. No Running Thread Shall Be Allowed. Conduit Runs Crossing Construction Joints Of The Building Shall Be Provided With Standard Expansion Fittings Of The Approved Type. No Conduits Shall Be Used In Any System Smaller Than 12 Mm Diameter Electric Trade Size Nor Shall Have More Than Four (4) 9o-degree Bends In Anyone Run And Where Necessary, Pull Boxes Shall Be Provided. All Ends Of Conduits Which Are Left Empty In Cabinets And Conduit Boxes Shall Be Plugged With Lead Or Approved Pipe Caps So As To Prevent The Entrance Of White Ants And Dirt Within The Conduit System. Pull Wires Shall Be Inserted In The Empty Ducts Before They Are Closed With Lead Or Pipe Caps And Shall Be Left Therein For Future Use. On Exposed Work, All Pipes And Outlet Boxes Shall Be Secured By Means Of Galvanized Metal Clamps Which Shall Be Held In Place By Means Of Machine Screws. When Running Over Concrete Surfaces, The Screws Shall Be Held In Place By Means Of Expansion Sleeves For Big Pipes And Rolled Lead Sheet For Small Pipes. All Pipes Shall Be Run At Right Angles To And Parallel With The Surrounding Walls. No Diagonal Run Shall Be Allowed And All Bends And Offsets Shall Be Avoided As Much As Possible. Conduits Shall Be Supported At 1,500 Mm Intervals Maximum. Conduit Boxes & Fittings Provide Conduit Boxes For Pulling And Splicing Wires And Outlet Boxes For Installation Of Wiring Devices. As A Rule, Provide Junction Boxes Or Pull Boxes In All Runs Greater Than 30 Meters In Length, For Horizontal Runs. For Other Lengths, Provide Boxes As Required For Splices Or Pulling. Pull Boxes Shall Be Installed In Inconspicuous But Accessible Locations. Support Boxes Independently Of Conduits Entering By Means Of Bolts, Red Hangers Or Other Suitable Means. Conduit Boxes Shall Be Installed Plumb And Securely Fastened. They Shall Be Set Flush With The Surface Of The Structure In Which They Are Installed Where Conduits Are Run Concealed. All Convenience And Wall Switch Outlet Boxes For Concealed Conduit Work Shall Be Deep, Rectangular Flush Type Boxes. Four-inch Octagonal Flush Type Boxes Shall Be Used For All Ceiling Light Outlets And Shall Be Of The Deep Type Where Three Or More Conduits Connect To A Single Box. Floor Mounted Outlet Boxes Required Shall Be Waterproof Type With Flush Brass Floor Plate And Brass Bell Nozzle. All Boxes Shall Be Painted With Antirust Red Lead Paint After Installation. All Conduits Shall Be Fitted With Approved Standard Galvanized Bushing And Locknuts Where They Enter Cabinets And Conduit Boxes. Junction And Pull Boxes Of Code Gauge Steel Shall Be Provided As Indicated Or As Required To Facilitate The Pulling Of Wires And Cables. General Specifications The Work To Be Done Under This Division Of Specifications Consists Of The Fabrication, Furnishing, Delivery And Installation, Complete In All Details Of The Electrical Work, At The Subject Premises And All Work Material's Incidental To The Proper Completion Of The Installation, Except Those Portions Of The Work Which Are Expressly Stated To Be 90ne By Other Fields. All' Works Shall Be Done In Accordance With The Rules And Regulations And With The Specifications. Specifications On: 1. Lighting Fixtures And Lamp A. All Lighting Fixtures And Lamps Are As Specified And Listed On Lighting Fixture Schedule. B. For Fluorescent Lamp, It Shall Be 40-watt Rapid Start Cool-white. All Fluorescent Ballast Shall Be 230 Volt, High Power Factor, Of Good Quality Materials And Approved By The Bureau Of Product Standards (bps). 2. Material Requirements All Materials To Be Used Shall Conform To The Bps Specification. 3. Construction Requirements A. All Grounding System Installation Shall Be Executed In Accordance With The Approved Plans. B. Grounding System Shall Include Building Perimeter Ground Wires, Ground Rods, Clamps, Connectors, Ground Wells And Ground Wire Taps As Shown In The Approved Design. Auxiliary Systems All Auxiliary Systems Such As Telephone And Intercom System, Time Clock System, Fire Alarm System And Public Address/nurse's Call/paging System Installations Shall Be Done In Accordance With The Approved Design. All Materials To Be Used Shall Conform To The Bureau Of Product Standards (bps) Specifications. Important Requirement Regarding Supervision Of The Work And Submission Of Certificate Of Completion. All Wiring Installation Herein Shall Be Done Under The Direct Supervision Of A Licensed Electrical Engineer At The Expense Of The Contractor. The Contractor Shall Submit The Certificate Of Completion Duly Approved By The Owner's Representative. Test And Guarantee Upon Completion Of The Electrical Construction Work, The Contractor Shall Provide All Test Equipment And Personnel And To Submit Written Copies Of All Test Results. The Contractor Shall Guarantee The Electrical Installation Are Done And In Accordance With The Approved Plans And Specifications. The Contractor Shall Guarantee That The Electrical Systems Are Free From' All Grounds And From All Defective Workmanship And Materials And Will Remain So For A Period Of One Year From Date And Acceptance Of Works. Any Defect Shall Be Remedied By The Contractor At His Own Expense. Method Of Measurement The Work Under This Item Shall Be Measured Either By Lengths, Pieces, Pairs, Lot And Set Actually Placed And Installed As Shown On The Approved Plans. Basis Of Payment All Works Performed And Measured And As Provided For In The Bill Of Quantities Shall Be Paid For At The Unit Bid Or Contract Unit Price Which Payment Shall Constitute Full Compensation Including Labor, Materials, Tools And Incidentals Necessary To Complete This Item. Payment Shall Be Made Under: Pay Item Number Description Unit Of Measurement 1100 Conduits, Boxes And Fittings (conduit Works / Conduit Rough-in) Lot Item 1101. Wires And Wiring Devices Description This Item Shall Consist Of The Furnishing And Installation Of All Wires And Wiring Devices Consisting Of Electric Wires And Cables, Wall Switches, Convenience Receptacles, Heavy Duty Receptables And Other Devices Shown On The Approved Plans But Not Mentioned In These Specifications. Material Requirements Wires And Cables Shall Be Of The Approved Type Meeting All The Requirements Of The Philippine Electrical Code And Bearing The Psa Mark. Unless Specified Or Indicated Otherwise, All Power And Lighting Conductors Shall Be Insulated For 600 Volts. All Wires Shall Be Copper, Soft Drawn And Annealed, Smooth And Of Cylindrical Form And Shall Be Centrally Located Inside The Insulation. All Wiring Devices Shall Be Standard Products Of Reputable Electrical Manufacturers. Wall Switches Shall Be Rated At Least 1 Oa, 250 Volts And Shall Be Spring Operated, Flush, Tumbler Type. Duplex Convenience Receptacles Shall Be Rated At Least 15a, 250 Volts, Flush, Parallel Slots. Single Heavy Duty Receptacles Shall Be Rated At Least 20a, 250 Volts. 3wire, Flush, Polarized Type. Construction Requirements Conductors Or Wires Shall Not Be Drawn In Conduits Until After The Cement Piaster Is Dry And The Conduits Are Thoroughly Cleaned And Free From Dirt And Moisture. In Drawing Wires Into Conduits, Sufficient Slack Shall Be Allowed To Permit Easy Connections For Fixtures, Switches, Receptacles And Other Wiring Devices Without The Use Of Additional Splices. All Conductors Of Convenience Outlets And Lighting Branch Circuit Home Runs Shall Be Wired With A Minimum Of 3.5 Mm In Size. Circuit Home Runs To Panel Boards Shall Not Be Smaller Than 3.5 Mm But All Home Runs To Panel Board More Than 30 Meters Shall Not Be Smaller Than 5.5 Mm. No Conductor Shall Be Less Than 2 Mm In Size. All Wires Of 14mm And Larger In Size Shall Be Connected To Panels And Apparatus By Means Of Approved Type Lugs Or Connectors Of The Solder Less Type, Sufficiently Large Enough To Enclose All Strands Of The Conductors And Securely Fastened. They Shall Not Loosen Under Vibration Or Normal Strain. All Joints, Taps And Splices On Wires Larger Than 14 Mm Shall Be Made Of Suitable Solder Less Connectors Of The Approved Type And Size. They Shall Be Taped With Rubber And Pvc Tapes Providing Insulation Not Less Than That Of The Conductors. No Splices Or Joints Shall Be Permitted In Either Feeder Or Branch Conductors Except Within Outlet Boxes Or Accessible Junction Boxes Or Pull Boxes. All Joints In Branch Circuit Wiring Shall Be Made Mechanically And Electrically Secured By Approved Splicing Devices And Taped With Rubber And Pvc Tapes In A Manner Which Will Make Their Insulation As That Of The Conductor. All Wall Switches And Receptacles Shall Be Fitted With Standard Bakelite Face Plate Covers. Device Plates For Flush Mounting Shall Be Installed With All Four Edges In Continuous Contact With Finished Wall Surfaces Without The Use Of Coiled Wire Or Similar Devices. Plaster Fillings Will Not Be Permitted. Plates Installed In Wet Locations Shall Be Gasketed. When More Than One Switch Or Device Is Indicated In A Single Location, Gang Plate Shall Be Used. Method Of Measurement The Work Under This Item Shall Be Measured Either By Meters, Rolls, Pieces, And Set, Actually Placed And Installed As Shown On The Plans. Basis Of Payment All Work Performed And Measured And As Provided For In This Bid Of Quantities Shall Be Paid For At The Unit Bid Or Contract Unit Price Which Payment Shall Constitute Full Compensation Including Labor, Materials, Tools And Incidentals Necessary To Complete This Item. Payment Shall Be Made Under: Pay Item Number Description Unit Of Measurement 1101 Wires And Wiring Devices Lot Item 1102. Power Load Center, Switchgear And Panel Boards, And Other Overcurrent Protection Devices Description This Item Shall Consist Of The Furnishing And Installation Of The Power Load Center Unit Substation Or Low Voltage Switchgear And Distribution Panel Boards At The Location Shown Or The Approved Plans Complete With Transformer, Circuit Breakers, Cabinets And All Accessories, Completely Wired And Ready For Service. Material Requirements All Materials Shall Be Brand New And Shall Be Of The Approved Type. It Shall Conform To The Requirements Of The Philippine Electrical Code And Shall Bear The Philippine Standard Agency (psa) Mark. Power Load Center Unit Substation The Contractor Shall Furnish And Install An Indoor-type Power Load Center Unit Substation At The Location Shown On The Approved Plans If Required. It Shall Be Totally Metal-enclosed, Dead Front And Shall Consist Of The Following Coordinated Component Parts: High Voltage Primary Section: High Voltage Primary Incoming Line Section Consisting Of The Following Parts And Related Accessories: A. One (1) Air-filled Interrupter Switch, 2-position (open-close) Installed In A Suitable Air Filled Metal Enclosure And Shall Have Sufficient Interrupting Capacity To Carry The Electrical Load. It Shall Be Provided With Key Interlock With The Cubicle For The Power Fuses To Prevent Access To The Fuses Unless The Switch Is Open. B. Three (3)-power Fuses Mounted In Separate Compartments Within The Switch Housing And Accessible By A Hinged Door. C. One 1) Set Of High Voltage Potheads Or 3-conductor Cables Or Three Single Conductor Cables. D. Lightning Arresters Shall Be Installed At The High Voltage Cubicle If Required. Items (a) And (b) Above Could Be Substituted With A Power Circuit Breaker With The Correct Rating And Capacity. Transformer Section The Transformer Section Shall Consist Of A Power Transformer With Ratings And Capacities As Shown On The Plans. It Shall Be Oil Liquid-filled Non-flammable Type And Designed In Accordance With The Latest Applicable Standards. The Transformer Shall Be Provided With Four (4 Approximately 2 1/2 % Rated Kva Taps On The Primary Winding In Most Cases One (1) Above And Three (3) Below Rated Primary Voltage And Shall Be Changed By Means Of Externally Gang-operated Manual Tap Changer Only When The Transformer Is De-energized. Tap Changing Under Load Is Acceptable If Transformer Has Been So Designed. The Following Accessories Shall Be Provided With The Transformer, Namely: Drain Valve, Sampling Device, Filling Connection, Oil Liquid Level Gauge, Ground Pad, Top Filter Press Connection, Lifting Lugs, Diagrammatic Nameplate, Relief Valve, Thermometer And Other Necessary Related Accessories. The High-voltage And Low-voltage Bushings And Transition Flange Shall Be Properly Coordinated For Field Connection To The Incoming Line Section And Low Voltage Switchboard Section, Respectively. Low-voltage Switchboard Section The Low-voltage Switchboard Shall Be Standard Modular-unitized Units, Metal-built, Dead Front, And Safety Type Construction And Shall Consist Of The Following: A. Switchboard Housing The Housing Shall Be Heavy Gauge Steel Sheet, Dead Front Type, Gray Enamel Finish Complete With Frame Supports, Steel Bracings, Steel Sheet Panel Boards, Removable Rear Plates, Copper Bus Bars, And All Other Necessary Accessories To Insure Sufficient Mechanical Strength And Safety. It Shall Be Provided With Grounding Bolts And Clamps. B. Secondary Metering Section The Secondary Metering Section Shall Consist Of One (1) Ammeter, Ac, Indicating Type; One (1) Voltmeter, Ac, Indicating Type, One (1) Ammeter Transfer Switch For 3-phase; One (1) Voltmeter Transfer Switch For 3phase; And Current Transformers Of Suitable Rating And Capacity. The Above-mentioned Instruments Shall Be Installed In One Compartment Above The Main Breaker And Shall Be Complete With All Necessary Accessories Completely Wired, Ready For Use. C. Main Circuit Breaker The Main Circuit Breaker Shall Be Draw-out Type, Manually Or Electrically Operated As Required With Ratings And Capacity As Shown On The Approved Plans. The Main Breaker Shall Include Insulated Control Switch If Electrically Operated, Manual Trip Button, Magnetic Tripping Devices, Adjustable Time Over Current Protection And Instantaneous Short Circuit Trip And All Necessary Accessories To Insure Safe And Efficient Operation. D. Feeder Circuit Breakers There Shall Be As Many Feeder Breakers As Are Shown On The Single Line Diagram Or Schematic Riser Diagram And Schedule Of Loads And Computations On The Plans. The Circuit Breakers Shall Be Draw Out Or Molded Case As Required. The Circuit Breakers Shall Each Have Sufficient Interrupting Capacity And Shall Be Manually Operated Complete With Trip Devices And All Necessary Accessories To Insure Safe And Efficient Operation. The Number, Ratings, Capacities Of The Feeder Branch Circuit Breakers Shall Be As Shown On The Approved Plans. Circuit Breakers Shall Each Be Of The Indicating Type, Providing "on" - "off" And "trip" Positions Of The Operating Handles And Shall Each Be Provided With Nameplate For Branch Circuit Designation. The Circuit Breaker Shall Be So Designed That An Overload Or Short On One Pole Automatically Causes All Poles To Open. Low-voltage' Switchgear (for Projects Requiring 'low-voltage Switchgear Only). The Contractor Shall Furnish And Install Low-voltage Switchgear At The Location Shown On The Plans. It Shall Be Metal-clad, Dead Front, Free Standing, Safety Type Construction And Shall Have Copper Bus Bars Of Sufficient Size, Braced To Resist Allowable Root Mean Square (rms) Symmetrical Short Circuit Stresses, And All Necessary Accessories. The Low-voltage Switchgear Shall Consist Of The Switchgear Housing, Secondary Metering, Main Breaker And Feeder Branch Circuit Breakers And All Necessary Accessories, Completely Wired, Ready For Service. Grounding System: All Non-current Carrying Metallic Parts Like Conduits, Cabinets And Equipment Frames Shall Be Properly Grounded In Accordance With The Philippine Electrical Code, Latest Edition. The Size Of The Ground Rods And Ground Wires Shall Be As Shown On The Approved Plans. The Ground Resistance Shall Not Be More Than 5 Ohms. Panel Boards And Cabinets Panel Boards Shall Conform To The Schedule Of Panel Boards As Shown On The Approved Plans With Respect To Supply Characteristics, Rating Of Main Lugs Or Main Circuit Breaker, Number And Ratings And Capacities Of Branch Circuit Breakers. Panel Boards Shall Consist Of A Factory Completed Dead Front Assembly Mounted In An Enclosing Flush Type Cabinet Consisting Of Code Gauge Galvanized Sheet Steel Box With Trim And Door. Each Door Shall Be Provided With Catch Lock And Two-(2) Keys. Panel Boards Shall Be Provided With - Directories And Shall Be Printed To Indicate Load Served By Each Circuit. Panel Board Cabinets And Trims Shall Be Suitable For The Type Of Mounting Shown On The Approved Plans. The Inside And Outside Of Panel Board Cabinets And Trims Shall Be Factory Painted With One Rust Proofing Primer Coat And Two Finish Shop Coats Of Pearl Gray Enamel Paint. Main And Branch Circuit Breakers For Panel Boards Shall Have The Rating, Capacity And Number Of Poles As Shown On The Approved Plans. Breakers Shall Be Thermal Magnetic Type. Multiple Breaker Shall Be Of The Common Trip Type Having A Single Operating Handle. For 50-ampere Breaker Or Less, It May Consist Of Single-pole Breaker Permanently Assembled At The Factory Into A Multi-pole Unit. Construction Requirements The Contractor Shall Install The Power Load Center Unit Substation Or Low-voltage Switchgear And Panel Boards At The Locations Shown On The Approved Plans. Standard Panels And Cabinets Shall Be Used And Assembled On The Job. All Panels Shall Be Of Dead Front Construction Furnished With Trims For Flush Or Surface Mounting As Required. Method Of Measurement The Work Under This Item Shall Be Measured Either By Set And Pieces Actually Placed And Installed As Shown On The Approved Plans. Basis Of Payment All Works Performed And Measured And As Provided For In The Bill Of Quantities Shall Be Paid For At The Unit Bid Or Contract Unit Price Which Payment Shall Constitute Full Compensation Including Labor, Materials, Tools And Incidentals Necessary To Complete This Item. Payment Shall Be Made Under: Pay Item Number Description Unit Of Measurement 1102 Power Load Center, Switchgear And Panel Boards, And Other Overcurrent Protection Devices Lot Item 1103. Lighting Fixtures And Devices Specifications On: Lighting Fixtures And Lamp A. All Lighting Fixtures And Lamps Are As Specified And Listed On Lighting Fixture Schedule. B. For Fluorescent Lamp, It Shall Be 40-watt Rapid Start Cool-white. All Fluorescent Ballast Shall Be 230 Volt, High Power Factor, Of Good Quality Materials And Approved By The Bureau Of Product Standards (bps). Material Requirements All Materials To Be Used Shall Conform To The Bps Specification. Construction Requirements A. All Grounding System Installation Shall Be Executed In Accordance With The Approved Plans. B. Grounding System Shall Include Building Perimeter Ground Wires, Ground Rods, Clamps, Connectors, Ground Wells And Ground Wire Taps As Shown In The Approved Design. Method Of Measurement The Work Under This Item Shall Be Measured Either By Set, Pieces, Or Lot Actually Placed And Installed As Shown On The Approved Plans. Basis Of Payment All Works Performed And Measured And As Provided For In The Bill Of Quantities Shall Be Paid For At The Unit Bid Or Contract Unit Price Which Payment Shall Constitute Full Compensation Including Labor, Materials, Tools And Incidentals Necessary To Complete This Item. Payment Shall Be Made Under: Pay Item Number Description Unit Of Measurement 1103 Lighting Fixtures And Devices Lot Item 1208. Fire Alarm System Manual Fire Alarm Bell Fire Alarm Bell Dimensions: 6" Or 150mm X 61mm Height Material: Metal Gong, Plastic Base Operating Voltage: 220v Ac+-5% Operating Current: 95db Break Glass Fire Alarm Switch Dimensions: 3-1/2" X 3-1/2" X 2" Https://drive.google.com/drive/folders/1m_6il4ggq7pv2auiduf0y0nk0b6rz5om?usp=sharing
Province Of Leyte Tender
Others
Philippines
Closing Date24 Feb 2025
Tender AmountPHP 1.3 Million (USD 22.9 K)
Details: Description 1 Lot Provision Of Labor, Supplies And Equipment For Water Parameters Of Dost-istart Seaweed Project Brgy. Dawahon Island Bato, Leyte 2 Pcs Temperature/light Data Logger Model Ua-002-64 2 Pcs Ph/temperature Data Logger Model Mx2501 2 Pcs Dissolved Oxygen Data Logger Model U26-001 2 Pcs Saltwater Conductivity/salinity Data Logger U24-002-c 1 Pc Waterproof Shuttle Model U-dtw-1 1 Pc Hoboware Software Model U-dtw-1 3 Pcs Microcentrifuge Tube Racks (1.5ml And 0.2ml) 5 Packs Pcr Tubes 0.2ml, Flat Caps (1000 Pcs/pack) 5 Packs 20 Ul White Pipet Tips (1000 Pcs/pack) 5 Packs 200 Ul Yellow Pipet Tips (1000 Pcs/pack) 1 Packs Ml Blue Pipet Tips (500 Pcs/pack) 25 Pcs Cryogenic Vial Boxes, Cardboard 2"superiorwhite Coated Cryobox With 100-well Divider, - 196° To 121° 3 Box Surgical Latex Gloves (100pcs/box) X-x-x-x-x-x-x-x-x-x-x-x-x-x
281-290 of 512 active Tenders