This Is Sources Sought Announcement Only. The Purpose Of This Notice Is To Conduct Market Research And Obtain Information From Qualified Businesses With Special Interest In Seeking Va Certified Service-disabled Veteran Owned Business (sdvosb); Veteran Owned Small Business (vosb) And Small Business For Small Business Concerns. No Solicitation Is Being Issued At This Time. This Notice Shall Not Be Construed As A Commitment By The Government To Ultimately Award A Contract, Nor Does It Restrict The Government To A Particular Acquisition Approach. Your Responses Will Be Due By Monday, November 14, 2022, 3:00pm (est) To The Point Of Contact Listed Below. All Information Submitted In Response To This Announcement Is Voluntary; The Government Will Not Pay For Information Requested Nor Will It Compensate Any Respondent For Any Cost Incurred In Developing Information Provided To The Government.
the U.s. Department Of Veterans Affairs, Network Contracting Office 6, And The Durham Veterans Affairs Medical Center Anticipate A Delivery For Neuroworks Dataserver. This Is A Vha Directive Requirement For The Facility To Obtain Equipment.
equipment:
1. 16 Tb Data Server - Rack 24u (neuroworks Server License Not Included), 1 Each
2. Upgrade Neuroworks/sleepworks 9.x Data Server Software,1 Each
3. Installation, 1 Each place Of Delivery:
durham Vamc
508 Fulton Street
durham, Nc 27705 the Appropriate Naics Code 541519 And The Small Business Size Standard Are $30.0 Million Interested
firms Are Reminded That In Accordance With Far 4.12, Prospective Contractors Shall Complete
electronic Annual Representations And Certifications In Conjunction With Far 4.11 Required
registration In The System For Award Management (sam) Database Prior To Award Of A Contract.
all Inquiries Shall Be Made To: Contracting Specialist: Latoya Glover; Nco 6,
durham, North Carolina; Email: Latoya.glover2@va.gov
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
United States
Closing Date4 Feb 2022
Tender AmountRefer Documents
Request For Information 1.0 Description
the Veterans Health Administration (vha) Non-expendable Equipment National Program Has Identified The Refractors: Manual Product Line As A Candidate For A Va-wide (otherwise Referred To As National ) Single Requirements Contract Award.
the Department Of Veterans Affairs (dva) Office Of Procurement, Acquisition And Logistics (opal) Strategic Acquisition Center (sac) On Behalf Of Vha Is Issuing This Request For Information (rfi) In Accordance With The Far 10.002(b)(2) To Determine The Availability And Technical Capabilities Of Qualified Sources. the Sac In Conjunction With Vha Is Seeking A Qualified Source To Provide Reichertâ® Brand Name Or Equal Refractors: Manual Refractors On An Agency Wide Basis. Va Intends To Award A Requirements Contract With Firm-fixed Price (ffp) Orders Iaw Far 16.503, Requirements Contract To A Supplier Of This Equipment. Vendors Will Be Required To Deliver Refractors: Manual To Va Medical Centers And Facilities Throughout The United States. the Anticipated Period Of Performance Is For One 12-month Base Period With Four 12-month Option Periods From The Date Of Award. However, The Government's Decision As To Whether Or Not To Continue With The Contract, Upon Annual Review, Will Be Based Upon Successful Performance During Each Previous Year And Continued Need.
the Associated North American Industrial Classification System (naics) Code For This Procurement Is 339112 Surgical Appliance And Supplies Manufacturing And The Associated Size Standard Is 1,000 Employees. The Far Provision Found At 52.204-7(b)(1) Requires That All Interested Offerors Must Be Registered In Sam Prior To Submitting An Offer Or Quotation. You May Access The Sam Website At Https://www.sam.gov/portal/public/sam/. All Quoters Must Be Certified With The Appropriate Naics Code On The Sam Website. All Sdvosb/vosb Offerors Must Be Verified In The Vendor Information Pages (vip) Database At: Https://www.vip.vetbiz.va.gov/ At The Time Of Quote Submission.
this Notice Is For Planning Purposes Only And Does Not Constitute A Commitment On The Part Of The Government To Award A Contract, Nor Does The Government Intend To Pay For Any Information Submitted As A Result Of This Notice. This Rfi Is Part Of A Continuous Process For Obtaining The Latest Information On The Commercial Status Of The Industry With Respect To Their Current And Near-term Abilities. The Information Provided Herein Is Subject To Change And In No Way Binds The Government To Solicit For, Or Award, A Competitive Contract. It Is Emphasized That This Is A Notice Solely For Planning And Informational Purposes.
2.0 Scope
refractors: Manual (or Phoropters) Are Designed To Measure The Refractive Error Of The Eye By Changing A Set Of Different Lenses Mounted In The Devices And Other Settings (also Known As Manual Refractors Or Phoropters) And Require The Examinee's Responses By Choosing Which Lenses Make The Vision Better. Phoropters Contain A Variety Of Lenses And They Require The Operator To Manually Change Lenses Until The Patient S Vision Is Clear. Phoropters Usually Consist Of A Refraction Unit Including A Set Of Calibrated (i.e., Containing A Number Of Plus And Minus Sphere And Cylinder Graduations) Lenses, A Cross-cylinder, A Pupillary Distance Setting, Prisms, Lens Controls, And An External Eye Chart. In Addition, Manual Refractors Are Phoropters That Are Generally Attached To A Stand That Also Includes A Slit Lamp. Manual Phoropters Measure Sphere Power And Cylinder Power And Axis, Accommodation, Convergence, And Binocular Balancing Of The Eyes. These Are Used Mainly To Establish Eyeglass Prescription.
the Contractor Must Demonstrate The Ability To Meet All Requirements For The Solicitation. The Objective Is To Provide Manual Phoropters To Be Used By Clinicians Throughout The Va Medical Centers And Facilities. The Period Of Performance Is For One (1) 12-month Base Period With Four (4) 12-month Option Periods.
the Following Contract Line Items Are Being Considered: contract Line Items
manufacture
part Number
description
0001
reichert
11625b
ultramatic Rx Master Phoroptor - Minus Cylinder
0002
reichert
11635b
ultramatic Rx Master Phoroptor - Plus Cylinder
0003
reichert
11636
ultramatic Rx Master Illuminated Phoroptor - Minus Cylinder
0004
reichert
11637
ultramatic Rx Master Illuminated Phoroptor - Plus Cylinder the Department Of Veterans Affairs (va) Is Seeking Vendors Who Can Provide Reichertâ® Refractors: Manual As Listed Above Or Equal Commodities Which Meet All Of The Following Salient Characteristics:
sc #
applicable Clins
salient Characteristics
method Of Eval
reichert
marco
sc 1
0001-0004
refracting Instrument Package To Include Plus (+0.12d And +2.00d) And Minus (-0.12d And -2.00d) Phoroptors, Face Shields, Nearpoint Card And Card Holder, Dust Cover And Power Cord
literature Review
pg4 Reichert Info .pdf
pg2 Marco Info .pdf
sc 2
0001-0004
instrument Must Have Energy-efficient Led Lighted Dials
literature Review
pg3 Reichert Info .pdf
pg2 Marco Info .pdf for Each Product (brand Name And Part Number), The Response Must Include Descriptive Literature Demonstrating The Product Meets Or Exceeds The Salient Characteristics (sc) Specified Above. the Government's Intent Is To Include All Ancillary Items To Ensure The Equipment Can Function As Designed By The Oem And As Clinically Required. Vendors Are Encouraged To Provide Any Product Solution Or Configuration So Long As They Meet The Salient Characteristics. Additionally, Responses Can Include Any Additional Product That May Be Beneficial. These Items Must Be Clearly Identified By Brand Name And Part Number.
responses To This Sources Sought Notice Shall Include The Following:
full Name And Address Of Company
duns Number
business Size
manufacturer Or Distributor
if Distributor Provide Full Name, Business Size And Address Of Manufacturer country Of Origin Designation For All Products
ability To Provide Uninterrupted Supply Of Products On A National Scale
technical Literature That Clearly Shows Product(s) Meet The Identified Salient Characteristics (if Submitting An Or-equal Item)
any Additional Product Solution Or Configuration That Would Be Beneficial To The Clinical Functionality Of The Product Line Identified
although Not Required, Vendors Responding To This Sources Sought May Also Submit A Capabilities Statement.
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
United States
Closing Date1 Mar 2023
Tender AmountRefer Documents
Install New Gas Line And Meter To Laundry Service, West Palm Beach Va Medical Center
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
United States
Closing Date27 Jul 2020
Tender AmountRefer Documents
G004--transitional Housing For Butler Veterans Administration Medical Center (bvamc)
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
United States
Closing Date15 Jul 2021
Tender AmountUSD 711.4 K This is an estimated amount, exact amount may vary.
Va Northern California Health Care System (mather, Ca)
redding Cboc Project
redding Outpatient Clinic
3455 Knighton Road
redding, Ca 96002 redding Outpatient Clinic
initial Outfitting, Transition & Activation Project
equipment Package
general Conditions And Statement Of Work
package #030
sterile Processing Equipment va Northern California Health Care System (mather, Ca)
redding Cboc Project
redding Outpatient Clinic
3455 Knighton Road
redding, Ca 96002 general Conditions And Statement Of Work
sterile Processing Equipment
page 2 Of 3
introduction
the Va Redding Outpatient Clinic (roc) Has A Requirement To Purchase Sterile Processing Equipment With An Authorized Vendor To Supply And Deliver The Item(s) Identified In Table 1 Below. This Requirement Is In Support Of A Brand Name. This Requirement Is In Support Of The Activation Of The Roc. Item(s) Are To Be Delivered To The Location Specified In Section 2.4.1.
table 1 Package Items Summary
item #
description/part Number*
qty
1
aqs2 - Acu-sinq 2 Chemistry Dosing System 2
2
se103502 - Install Acu-sinq 2
2
3
se1035010045 - 1st Year Pm Acu-sinq 2
2
4
iw523046npr - Innowave Unity15 Gal Sonic Irrigator 1
5
mp22699 - Innowave Unity 15 Gal Seismic Anchoring 1
6
se130202 - Install Innowave Unity
1
7
se0000082 - Seismic Anchoring 1
8
se1302010045 - 1st Year Pm Innowave Unity
1
9
fh18043 - Amsco 7052hp, 460-480v, 3 Ph, 60 Hz, Electric Heated Amsco 7052hp Washer/disinfector 2
10
fd037 - Installation Kit, Flexible Hoses For Utilities 2
11
fd094 - Protocol Printer
2
12
fd354 - Seismic Tie-down Kit
2
13
fd361 - Drain Acu-cooldown
2
14
fd74900 - 3 Level Manifold Rack 3 Level Manifold Rack
4
15
fd199 - Auto Docking Transfer Cart For Standard Chamber Washer
4
16
fd209 - Auto Docking Tc Adapter For Washer 4
17
se101682 - Install Amsco 7052hp
2
18
se0000082 - Seismic Anchoring 2
19
se1016810045 - 1st Year Pm Amsco 7052hp
2
20
fd24100 - Rack Return For 444/synergy Rack Return Module
1
21
se101402 - Installation, Rack Return
1
22
vp50002101 - V-pro Max 2 Sterilizer 208-230v
1
23
p146669354 - V-pro 1 Seismic Kit
1
24
lcb046 - Celerity Hp Incubator
1
25
se600962 - Install Large Hydrogen Peroxide Sterilizers
1
26
se0000082 - Seismic Anchoring 1
27
se6009810000103 - 1st Year Deep-vacuum Pump Service V-pro Max
1
28
ef1102442 - Amsco 600 Prevac Steam Sterilizer, 26.5x26.5x39, Electric, 2
29
ay1596152 - Amsco 600 Sterilizer Chamber Rail (39in, 990mm)
2
30
ay1598102 - Amsco 600 Transfer Carriage, Fixed Height (39in, 990mm)
5
31
ay1596602 - Amsco 600 Loading Car With 2 Shelves (39in, 990mm)
5
32
ef0000000000000001 - Amsco 600 Seismic Kit
2
33
se011492 - Install Amsco 600 Electric
2
34
se0000082 - Seismic Anchoring 2
35
se0114910045 - 1st Year Pm Amsco 600 Electric
2 general Conditions
site Address
the Address Of The Va Redding Outpatient Clinic Is Listed Below. Additional Information On Delivery Is Located In Section 2.4.
redding Outpatient Clinic
initial Outfitting, Transition And Activation Project
3455 Knighton Road
redding, Ca 96002
delivery Schedule
items Shall Be Delivered No Earlier Than The Estimated Delivery Start Date And No Later Than The Delivery End Date Listed In Table 2 Below.
table 2 Anticipated Building Outfitting Schedule
building Name
building # & Letter
acronym
est. Delivery Start Date
est. Delivery End Date
va Redding Outpatient Clinic roc
2021-09-06
2021-10-29 schedule And Order Management
the Above Delivery Schedule Is Based Upon The Current Construction Schedule, Which Is Subject To Change. The Vendor Shall Not Increase Prices For A Change In Delivery Date For Up To 30 Days To 90 Days.
the Awardees Actual Delivery Dates Will Be Confirmed By Va Upon Award.
post-award The Vendor Will Coordinate Delivery Prior To Beginning Any Work (see Section 2.4). Once The Dates Have Been Confirmed, Modifications To The Schedule Are Subject To Written Approval By The Va Poc And The Vendor. Schedule Changes That Are Beyond The Dates Specified In The Contract Will Require Approval By The Contracting Officer And A Contract Modification.
delivery And Receiving
delivery And Receipt Of The Proposed Items Is Anticipated To Be Directed To The Location Identified Below. Confirmation Of Delivery Location Will Be Provided By The Va Poc Post-award. Delivery Must Be Coordinated With Va Logistics Poc Daniel Chavez, 940-782-0724 Prior To Any Attempts At Delivery. Any Item That Has Not Been Coordinated Will Be Turned Away And Any Additional Charges Will Be The Responsibility Of The Sender/transportation Company. Va Redding Outpatient Clinic
(direct Delivery To Address Detailed In Paragraph 2.1.1) Warehouse
13290 Contractors Lane
building #2
chico, Ca 95973
delivery Shall Be Freight On Board (fob) Destination.
the Vendor Is Required To Define The Need For A Staging Area To Accommodate Item Delivery, If Needed. Post-award, This Information Will Be Confirmed With The Vendor.
the Delivery Of Items Identified In This Document Shall Take Place During Normal Business Hours Which Are Defined As: 0800 To 1630 (i.e.: 8:00am To 4:30pm Pacific Time), Monday Through Friday, And Excluding Federal Holidays.
delivery Trucks Will Not Be Permitted To Remain At The Loading Dock. Trucks Shall Be Unloaded, Moved From The Dock, And Then Brought Back To The Dock If Required To Haul Out Any Waste, Tools, Or Excess Materials.
labeling Of Delivered Items Shall Include The Awarded Contract Number And Va Purchase Order Number For Identification And Reference Upon Receipt Of Product.
use Of Warehouse
if The Vendor Requires The Use Of The Government S Activation Contractor S Warehouse To Meet The Requirements Of This Contract The Vendor Must Provide A Certificate Of Insurance Prior To The Delivery And Offloading Of The Item(s). This Insurance Certificate Must Be Completed And Presented To The Activation Contractor Prior To Delivery.
the Vendor Shall Communicate Through The Va Poc Any Required Coordination Requirements.
clean Up And Disposal
there Are No Dumpsters Available For Vendor Use.
the Removal Of Waste And/or Excess Material Shall Be Conducted Through The Loading Dock Area. Delivery Trucks And/or Other Vendor Vehicles Will Not Be Permitted To Remain At The Loading Dock. Vehicles Will Need To Be Brought Back To The Dock If Required To Remove Any Waste, Tools, Or Excess Materials.
deliverables [ ' ' Is ' ' Is Not Required]
the Vendor Shall Provide Cad Drawings (including Shop Drawings) And Specifications For Site Prep For Their Product As Required.
the Vendor Shall Provide A Completed Va Form 6550 With Submittal Documents For Any And All Item(s) That May Connect To The Va Network And Medical Devices That Store Sensitive Patient Information.
assembly And Installation [ Is Is Not Required]
the Vendor Is Required To Manage And Coordinate Installation At The Va Roc With The Va Poc.
on-site Assembly And Installation Of Items, And Performance Of Services Identified In This Document Shall Take Place During Normal Business Hours Which Are Defined As: 0800 To 1630 (i.e.: 8:00am To 4:30pm Pacific Time), Monday Through Friday, And Excluding Federal Holidays.
the Vendor Is Required To Define The Need For A Staging Area To Accommodate Item Assembly And Installation, If Needed. Post-award, This Information Will Be Confirmed With The Vendor.
the Vendor Is Required To Provide Tools, Labor And Materials To Complete Assembly And Installation Of The Items Detailed In This Document.
the Vendor Shall Protect All Finished Spaces And Surfaces As Required From Delivery And Installation Damage. The Vendor Shall Use Covering And Protection To The Extent Necessary To Prevent Damage To Finished Spaces. Any Damage Occurred During Delivery And Installation Is The Responsibility Of The Vendor. The Vendor Will Be Responsible For Paying For And Repairing Any Damage Or Noted Deficiencies To Finished Spaces And Surfaces That Occur As A Result Of The Vendor S (or Associated Sub-contractors) Installation.
during The Entire Duration Of Assembly And Installation, The Vendor Will Have A Competent Representative On-site As The Vendor S Contact, And To Serve As The Interface Between The Vendor And Va Roc. On-site Representative Can Be The Installer. All Instructions Provided From Cor To The Representative Will Be Binding As If Given To The Vendor S Main Contact. The Cor May Provide Specific Instructions, However, Only The Contracting Officer May Change The Terms Or Conditions Of The Contract.
training [ Is Is Not Required]
the Vendor Shall Coordinate Through The Va Poc To Provide A Hands-on Training Session To Staff Selected By The Va. Training Shall Be Completed Within 45 Days After Final Installation Of Equipment. The Vendor Will Record The Training And Provide An Electronic Copy Of The Training To The Va Poc For Va To Use To Train Additional Personal At A Future Date. In Addition, The Vendor Shall Provide Additional Training Documents To The Va Poc For Training Additional Persons At A Future Date.
standard Warranty
the Products Shall Be Covered By Vendor S Standard Warranty Terms And Provisions, Provided, However, That The Warranty Coverage Shall Be No Less Than The Following:
the Vendor Shall Provide A Warranty Certificate/form Stating The Warranty Period, Terms, And Information Required To Initiate The Warranty. the Warranty Period Set Forth Therein Shall Run For One Year Following The First Day Of Use At Roc;
the Vendor Shall Extend Such Warranty Directly To The Customer As If Such Customer Had Purchased The Products Directly From The Vendor;
the Vendor Shall Warrant The Products Against Defects In Material And Workmanship Under Normal Use And Service, Repair Or Replace At Vendor S Cost Any Defective Product (or Issue A Credit Or Refund, As The Case May Be, Based On The Purchase Price Paid Therefor); And
the Vendor Shall Pay (or Refund The Amount Of) All Freight And Shipping Charges For Any Defective Products Returned Under This Paragraph.
use Of Premises
if During The Performance Of This Contract, Work Will Be Carried Out On Va Roc Premises, The Vendor Shall Perform All Work In Such A Manner That Will Cause A Minimum Interference With Va Roc Operations And The Operations Of Other Contractors On The Premises.
the Vendor Shall Communicate Through The Va Poc Any Required Coordination Requirements With The General Construction Contractor Prior To And During Delivery And Installation Activities.
the Project May Be An Active Construction Site During Delivery And Installation. The Vendor Shall Take All Necessary Precautions To Protect The Premises And All Persons And Property Therein From Damage Or Injury. The Vendor Shall Assume Responsibility For Taking Precautions For The Vendor's (and Associated Subcontractors ) Employees, Agents, Licensees, And Permittees. The Vendor Shall Abide By Any Safety Requirements Imposed By The Gc (e.g., Hard Hats, Safety Vests). general Conditions And Statement Of Work
package 030: Sterile Processing Equipment
page 6 Of 6
redding Cboc Project
s0237
13290 Contractors Lane, Building #2
chico, Ca 95973 _
project: Redding Cboc Project
issue Date: February 2021
_
total Quantity: 2 Finish Sample Required If Checked Manufacturer Certified Installation Required If Checked
_ Bmet Training Required If Checked End User Training Required If Checked
_
item Name: Sterilizer, Electric, Vac, 1 Do, Cab, 20"x20"x38" Chamber
brand Name: Steris Corporation | Evolution Hc900 Sfpp 26x37.5x42 Dd Hng L/r 480v | Ue01113201001
width: 49.5 In. Depth: 48 In. Height: 77.25 In.
salient Characteristics: Main Image:
recessed, Electric Steam Sterilizer With 26 Inches X 37.5 Inches X 42 Inches Chamber, Left-hand/right-hand Hinged Doors, With Pc Based Control System And Copper/brass Steam Plumbing. 480v Integral Electric Steam Generator. Recessed Through 2 Walls. Steam Flush Pressure Pulse (sfpp) Prevacuum, Gravity, Liquid, Dart (bowie-dick) And Vacuum Leak Test Cycles. Include (5) Fixed Height Transfer Carriages & (5) 2-shelf Loading Cars general Conditions And Statement Of Work
package 030: Sterile Processing Equipment
page 7 Of 7
redding Cboc Project
s0940
13290 Contractors Lane, Building #2
chico, Ca 95973 _
project: Redding Cboc Project
issue Date: February 2021
_
total Quantity: 2 Finish Sample Required If Checked Manufacturer Certified Installation Required If Checked
_ Bmet Training Required If Checked End User Training Required If Checked
_
item Name: Washer/disinfector
brand Name: Steris Corporation | Amsco 2532 Double Door 480v (non-vented) | Fh120116
width: 28.5 In. Depth: 28.5 In. Height: 78 In.
salient Characteristics: Main Image:
single-chamber Washer/disinfector With Touch Screen Control. Features: Non-vented, 480v/60hz. 1 Wall Flange. Chamber Dimensions: 25 X 25-1/2 X 25-1/4. Double, Manual, Drop-down Glass Doors. Includes Wall Flange Components For One Side. Intended For Use In The Cleaning And Intermediate-level Disinfection Of Soiled Reusable Utensils, Trays, Glassware, Rubber, And Plastic Goods And Simple Hard-surfaced Rigid Surgical Instruments (such As Forceps And Clamps). 4-transfer Carts, 4-3 Level Manifold Racks. Installation, Installation Kits, Seismic Requirement, general Conditions And Statement Of Work
package 030: Sterile Processing Equipment
page 8 Of 8
redding Cboc Project
s1900
13290 Contractors Lane, Building #2
chico, Ca 95973
mtr Steris
_
project: Redding Cboc Project
issue Date: February 2021
_
total Quantity: 1 Finish Sample Required If Checked Manufacturer Certified Installation Required If Checked
_ Bmet Training Required If Checked End User Training Required If Checked
_
item Name: Rack, Return, Automatic
brand Name: Steris | Reliance 444 Rack Return Module | Fd24100
width: 34 In. Depth: 47 In. Height: 67 In.
salient Characteristics: Main Image:
- Vertical Sliding Door Maximizes Floor Space. Power Door Opens And Closes At The Touch Of A Button.
- Automatic Detergent Injection Assures That The Right Amount Of Detergent Is Dispensed Into The Water.
- Tinted, Tempered Glass Door Lets You Verify Cleaning Action While Providing Excellent Insulation. An Interior Light Gives A Clear View Of Load Contents And Washing Activity.
- Choice Of Gentle Of Aggressive Mechanical Action. The Dual Speed Pump Lets You Control Water Pressure And Solution Coverage.
- Rotary Arms Located At Top And Bottom Of Each Level Provide Maximum Solution Coverage With Bi- Directional Spray Pattern Designed To Increase The Cleaning Capacity.
- Exhaust System Assures That Vapor Is Removed From The Wash Chamber Between Cycles For Improved Temperature Control And Faster Load Drying. general Conditions And Statement Of Work
package 030: Sterile Processing Equipment
page 9 Of 9
redding Cboc Project
s2640
13290 Contractors Lane, Building #2
chico, Ca 95973 _
project: Redding Cboc Project
issue Date: February 2021
_
total Quantity: 1 Finish Sample Required If Checked Manufacturer Certified Installation Required If Checked
_ Bmet Training Required If Checked End User Training Required If Checked
_
item Name: Cleaner, Ultrasonic, Console, Dbl Chmbr, Cab, F/s
brand Name: Steris Corporation | Innowave Pcf Sonic Irrigator | Iwpcf
width: 58.75 In. Depth: 34.25 In. Height: 44.75 In.
salient Characteristics: Main Image:
irrigator Is Designed To Thoroughly Clean (remove Tissue, blood And Other Contaminants) A Variety Of reusable Surgical Instruments. Provides Sonic Irrigation (ultrasonic Cavitation) To Both The Interior And Exterior Of Lumened Instruments. The System Also Uses Power Flush (approximately 44 Psi) When Instruments Are Connected To Remove Debris From The Inside Channels. Unit Is Equipped With Intermediate Level Thermal Disinfection To Ensure Instruments are Safe For The Staff To Handle At The End Of The Cycle. requires Di Water general Conditions And Statement Of Work
package 030: Sterile Processing Equipment
page 10 Of 10
redding Cboc Project
s5505
13290 Contractors Lane, Building #2
chico, Ca 95973 _
project: Redding Cboc Project
issue Date: February 2021
_
total Quantity: 1 Finish Sample Required If Checked Manufacturer Certified Installation Required If Checked
_ Bmet Training Required If Checked End User Training Required If Checked
_
item Name: Sterilizer, Hydrogen Peroxide Gas, 3.5 Cu Ft Cham
brand Name: Steris Corporation | Amsco V-pro Max (cabinet) | Vp30002101
width: 33 In. Depth: 38.5 In. Height: 75.25 In.
salient Characteristics: Main Image:
cabinet-mounted, Low Temperature/hydrogen Peroxide Sterilizer With Single Door. For Use In The Terminal Sterilization Of Cleaned, Rinsed, Dried Reusable Metal And Nonmetal Medical Devices That Are Sensitive To Heat And Moisture. 136l Capacity, Automatic Door Lock, Color Touch Panel With 10.4" Screen, Built-in Printer. Three Pre-programmed Sterilization Cycles: Lumen, Non-lumen And Flexible Cycles. general Conditions And Statement Of Work
package 030: Sterile Processing Equipment
page 11 Of 11
redding Cboc Project
u3314
13290 Contractors Lane, Building #2
chico, Ca 95973
mtr Steris
_
project: Redding Cboc Project
issue Date: February 2021
_
total Quantity: 2 Finish Sample Required If Checked Manufacturer Certified Installation Required If Checked
_ Bmet Training Required If Checked End User Training Required If Checked
_
item Name: Chemistry Dosing System
brand Name: Steris | Acu-sinq 2 Chemistry Dosing System | Null
width: 7 In. Depth: 16 In. Height: 4 In.
salient Characteristics: Main Image:
the Chemistry Dosing System Is A Dispensing System Used To Transfer Precise Amounts Of Pre-soak Chemicals Into A Pre-wash
sink. This Chemistry Dosing System Uses An Electronically Controlled Peristaltic Pump To Dispense Detergent. Multiple Dosing Levels Can Be Programmed To Meet Specific Soil Conditions For Full And Half Sink Levels Providing Optimal Cleaning Results Prior To Automated Decontamination Steps. the System Is Comprised Of:
- Main Control/pump Unit
- Water Temperature Monitor
- Chemistry Supply Line With Weight And Filter
- Chemistry Discharge Line With Check Valve And Attaching Hardware
- Usb Output For The Capture And Recording Of Process Data And Chemistry Usage
system Is Not For Use In Potentially Explosive Environments