Valve Tenders

Valve Tenders

Prasar Bharati Broadcasting Corporation Of India Tender

Goods
Electrical Goods and Equipments...+1Electrical and Electronics
GEM
Corrigendum : Corrigendum Added
India
Closing Date25 Oct 2024
Tender AmountINR 200 K (USD 2.3 K)
Description: CATEGORY: Stationary Valve Regulated Lead Acid Batteries (V2) as per IS 15549 (Q3)

South Central Railway - SCR Tender

Auction
Ireps
Corrigendum : Closing Date Modified
India
Closing Soon28 Feb 2025
Tender AmountRefer Documents 
Description: Cond/scrap Alco Diesel Locomotive -vijayawada-pl No: 98112326 [hsn Code-86079100]. Cond/scrap Alco Diesel Locomotive No-11117 Wdm3d, 11123 Wdm3d And 11136 Wdm3d Of Dls/bza. Consisting Of-main Chassis-chassis Fuel Tank, Cattle Guard With Stay Rods, Mr Air Tanks, Engine Blocks, Cylinder Head Assembly, Cylinder Head Studs, Valve Leaver , Cylinder Liners, Fip Supports, Fips, Dampers, Vibration Damper Housings, Modified Steel Cap Pistons, Crank Shaft Gear, Crank Shaft Dampers, Crank Shaft , Cam Shaft Bushings, Cam Shaft Gears, S-pipes, Main Bearings, Gudgeon Pins, Connecting Rod Assembly, Fuel Control Shaft, Extension Shafts, Extension Shaft Gears, Turbo Super Chargers, Tsc Supports, Turbo Air Larger After Cooler, Lubricating Oil Pumps, Fuel Oil Header, Push Rods, Push Rod Spacer, Fuel Jumpers, Water Jumpers, Water Risers, C/r Bushing With Nut & Bolts, Copper Pipes, Engine Base Sumps, On Line Lube Oil Centrifuge, Piston Rings, System Pipes, Lube Oil Coller (ptloc), Fuel Oil Filter Housing, Fast Coupling, Flexible Coupling, Rttm Blowers, Lube Oil Filter Drum, Inter Cooler Air Compressor, Radiator2-core Modified, Air Compressor, Fttm Blowers, Horizontal Shaft With Pulley, Right Angular Gear Box With U-shaft, Truck Without Traction Motors And Wheel Sets, Bogie Frame, Equalizers, Compensating Beams, Vertical Links, Outer Coil Springs, Inner Coil Springs, Spring Seaters, Brake Cylinders, Brake Hanger With Brake Heads, Brake Cylinder Pipes, Fish Plates, Re Silent Pads, Pull Rods, Slack Adjuster Assembly, Stay Plate, Gear Case, Vertical Dampers, Latter Dampers, Axle Boxes, Hnbc With Bearings, Hand Brake Assembly, Engine Hood Consisting Of - Power Pack Hoods, Driver Cabins, Radiator Compressor Hoods, Radiator Fan With U-shaft And Pedestal, Fuel Oil Gauge, Water Expansion Tank, Traction Alternator Without Brush Arm, Exciter Generator Without Brush Arm, Traction Motors, Armature With Fittings, Bkbl, Power Cables, Control Wires, Ccem, Dem, Water Pump, Pe End Shield With Bearing, Ce End Shield With Bearing, Pinion, Lube Oil Pump, Ost Unit, Ep Contactors, Control Drums, Fpm, Bkt, Rev, Gf Contactor, Resister Grid, Rectifier, Wood Ward Governor Base, Head Light, Classification Light, Ecc Drum Brush Holder, Cranking Contactor, Flasher Light, Speedometer With Pulse Generator, Air Maize, Exhaust Manifold Set, J-filter Housing, Load Pad, Miscellaneous With All The Above Items Contains ¿ferrous-264258.93kg, Copper-23291.64kg, Brass-2710.08kg, Aluminium-1235.04kg, Total Qty-291.496 Mt. (these Weights Are Obtained As Per Ds-8). All Weights Are Given By The Custodian. The Locomotive Is Available At Compound Of Dls/bza. Under Control Of Sse/loco/bza. Sold On Number Basis And Delivery On By Lot Basis. Cutting Is Permitted For Loading Purpose. This Locomotive Consisting Of Rc- Items-1) Wheel Sets With Bull Gear Suspension Tube-18-nos. 2) 8v 450/500 Ah Lead Acid Batteries -24nos.3) Loco Side Buffers-12nos, 4) Cbc Coupler Unit With Draft Gear-06nos. Note-a) The Above Rc-items Should Return To The Railways Before Effecting The Delivery Of The Cut Parts Of The Locomotive. B) The Purchaser Should Keep The Similar Items As Separate Heap. C) The Purchaser Must Clean The Cutting Area After Completion Of Delivery. Ds-8 No: 236200019/20/21. Dt.14/09/2024.

Indian Army Tender

Goods
Healthcare and Medicine
GEM
Corrigendum : Corrigendum Added
India
Closing Date5 Oct 2024
Tender AmountINR 2.6 Million (USD 30.1 K)
Description: CATEGORY: Hollow Fibre Dialyser Polysulphone by Polyurethane by Polyamide Size 1 point 4 m2 to 1 point 7 m2 , Tab Desidustat 100 mg , Cap Enzobiotics , Cap Aminase , Nitrophage Forte Sachet , Argyle Fistula needle cannula anti reflux valve integrated safety needle stick prevention mech sd hv multiple holes at cannula tip for shower flow flow rate of 400ml by hr Size 16 inch 30mm , hemodialyser med flux pore size more than 2 pt 2 nm having kuf more than 14 ml per min per mmhg in line steam sterilisation with biocompsynt membrane b2 microglobulin , hemodialyser medium flux pore sizemore than 3 point 3 nm having kuf more than 20 ml by min bymmhg in line steam sterilisation biocompatible synthetic membrane , haemodialysis dble lumen cathr curved adult insertion set complete 11 pt 5 fr 13 poiint 5 cm dilator 12f and 9f ptfe by nitinol ported j tip wire on loader 0 point 35x50 cm introducer needle , Hollow Fibre Dialyser Polysulphone by Polyurethane by Polyamide Size 1 point 8 m2 to 2 point 0 m2 with tubing , Chronic Dual Lumen Catheter 14 point 5 Fr by Ch 4 point 8Mm X 19Cm A 1 point 6Mm V 1 point 7Ml With Dual Cuff Tunneled Staggered Tip Without Sides Holes Tunneled Catheter Size 36Cm , Part A can for bibag 10 ltr , TOLVAPTAN 15MG Tab , Alpha Ketonalogue 200mg Tab

South Central Railway - SCR Tender

Auction
Scraps
Ireps
Corrigendum : Closing Date Modified
India
Closing Soon28 Feb 2025
Tender AmountRefer Documents 
Description: C.b Cut Parts, 98050047(15) Cond.& U/s Ms Scrap Of C.b.cut Parts Consisting Of Vestibule Foot Plates,ms Coach Main Doors, Soul Bar Cut Pieces, Head Stock Beams, Foot Steps Icf/ Beml,trough Floor Sheets, End & Side Body Cut Parts ,body Cut Plates, Seat Frames, Luggage Frames, Partition Frames, Drain Pipe Pieces, Taps, Battery Box Doors, Cocks, Valves, Ms Flats, Ms Pipes, Door Closer, Carriage Doors And Cut Parts, Flush Out Cocks And Ms Commode Chutes Neck Ring And Boxes Cut Pieces ,push Valves, Ms Wire Claws, Ms Shovels, Ms Pan Motors, Door Handles, Other Misc C B Cut Parts, Etc., With Or Without Stainless Steel Attachments. Note:1) Delivery On Actual Weighment Basis Only. 2)if Any Ss/non-ferrous Items Found During Loading /delivery Shall Be Returned To The Railways By The Purchaser.3) Segregation Not Permitted. Hsn Code:72044900 Gst@18% On Forward Charge Basis.location: Ferrous Yard, Bin No:h-5 & H-6.

DEPT OF THE NAVY USA Tender

Others
Corrigendum : Closing Date Modified
United States
Closing Soon28 Feb 2025
Tender AmountRefer Documents 
Description: Contact Information|4|n713.30|gls|717-605-1308|joshua.j.eshleman.civ@us.navy.mil| item Unique Identification And Valuation (jan 2023)|19|||||||||||||||||||| higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|iso9001| inspection Of Supplies--fixed-price (aug 1996)|2||| wide Area Workflow Payment Instructions (jan 2023)|16|combo - Invoice And Receiving Report||tbd|n00104|tbd|tbd|tbd|tbd|||tbd|||||| navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|wss| equal Opportunity (sep 2016)|2||| buy American-free Trade Agreements-balance Of Payments Program-basic (feb 2024)|11|||||||||||| option For Increased Quantity (mar 1989)|1|180 Days| alternate A, Annual Representations And Certifications (nov 2023)|13|||||||||||||| buy American-free Trade Agreements-balance Of Payments Program Certificate-basic (feb 2024))|5|||||| buy American-balance Of Payments Program Certificate-basic (feb 2024)|1|| annual Representations And Certifications (may 2024)|13|332919 |750|||||||||||| notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2||x| the Purpose Of This Amendment Is To Update The Solicitation Due Date To 28 February 2025 And To Update The Tdp Part# To Incorporate 1315-w07h 6in Or 1315-w07h 600 Eaf/sepa this Procurement Action Is Issued Pursuant To Emergency Acquisition Flexibilities (eaf/sepa) Iaw Far 13.201(g) And Far Subpart 18.2". Accelerated Delivery Is Encouraged And Accepted Before The Delivery Date(s) Listed In The Schedule. ^^ all Freight Is Fob Origin. this Rfq Is For A Buy/new Manufacture. The Resultant Award Of This Solicitation Will Be Issued Bilaterally, Requiring The Contractor?s Written Acceptance Prior To Execution. Verify Nomenclature, Part Number, And Nsn Prior To Responding. government Source Inspection And Acceptance Are Required. Unit Price:__________ Firm Total Price:__________ Firm Procurement Turnaround Time (ptat) :__________ Awardee Cage: __________ Inspection & Acceptance Cage, If Not At Source:__________ Delivery Vehicle (if Delivery Order Requested) (if Your Company Has A Current Boa/idiq, For Example):__________ if You Are Not The Manufacturer Of The Material You Are Offering, You Must State Who The Manufacturer Is (name & Cage Code) And Be Able To Provide Traceability Information If Requested Prior To Receiving An Award. by Submitting A Quotation Or Offer, The Contractor Agrees That, When The Contractor Is Not The Manufacturer Of The Item, It Is Confirming That It Currently Has Or Will Obtain Before Award And Shall Retain Documented Evidence (supply Chain Traceability documentation) That The Item Is From The Approved Manufacturer And Conforms To The Technical Requirements. The Retention Period Is Five Years After Final Payment Under This Contract. at A Minimum, The Supply Chain Traceability Documentation For The Item Shall Include: Basic Item Description, Part Number And/or National Stock Number, Manufacturing Source, Manufacturing Sources Commercial And Government Entity (cage) Code, And Clear identification Of The Name And Location Of All Supply Chain Intermediaries Between The Manufacturer To The Contractor To Item(s) Acceptance By The Government. The Documentation Should Also Include, Where Available, The Manufacturer's Batch Identification For The time(s), Such As Date Codes Lot Codes, Or Serial Numbers As Date Codes Lot Codes, Or Serial Numbers. the Contracting Officer Would Like To Exercise A 100% Option Quantity Within 180-days Of The Effective Date Of Contract Award. The Contractor Will Provide The Same Delivery Turnaround As The Base Line Items. A Modification Will Be Completed At The Time The Option Is Exercised And All Current Contract Terms And Conditions Will Apply To The Option Quantity. please Indicate If The Contracting Officer May Exercise The 100% Option Quantity For This Contract. yes __ Or No __ please Indicate The Pricing For The Option Quantity. price Each: $___________ navsupwss Poc: Joshua.j.eshleman.civ@us.navy.mil \ 1. Scope 1.1 This Contract/purchase Order Contains The Requirements For Manufacture And The Contract Quality Requirements For The Valve,gate . 2. Applicable Documents 2.1 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions. 2.1.1 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order. 3. Requirements 3.1 Cage Code/reference Number Items - The Valve,gate Furnished Under This contract/purchase Order Shall Be The Design Represented By Cage Code(s) reference Number(s). Cage _______ Ref. No. ;76364 1315-w07h 6in 76364 1315-w07h 600; 3.2 Marking - This Item Shall Be Physically Identified In Accordance with ;mil-std-130, Rev N, 16 Nov 2012; . 3.3 Changes In Design, Material Servicing, Or Part Number - Except For A Code 1 Change, Which Shall Be Processed As Provided In The Code Statement Shown Below, No Substitution Of Items Shall Be Made Until The Navicp-mech Contracting Officer Has Notified And approval Has Been Given By Issuance Of A Written Change Order. When Any Change In Design, Material, Servicing Or Part Number Is Made To Replace Or Substitute Any Item To Be Furnished On This Contract/purchase Order, The Contractor Shall Furnish, For The substituting/replacement Item, A Drawing And An Explanation Of The Reason For The Change, Explaining The Reason Therefor. If Finished Detail Drawings Are Not Available, Shop Drawings In The Form Used By The Manufacturer Will Be Acceptable For Government evaluation. When Notifying The Procurement Contracting Officer Of The Reasons For Making Substitutions, The Type Of Change Shall Be Indicated By Code Number In Accordance With One Of The Following Statements: code 1: Part Number Change Only - If The Manufacturer's Part Number Indicated Thereon Has Changed, But The Parts Are Identical In All Respects, Supply The Item And Advise Navicp-mech Immediately Of The New Part Number. code 2: Assembly (or Set Or Kit) Not Furnished - Used Following Detail Parts. code 3: Part Not Furnished Separately - Use Assembly. code 4: Part Redesigned - Old And New Parts Are Completely Interchangeable. code 5: Part Redesigned - New Part Replaces Old. Old Part Cannot Replace New. code 6: Part Redesigned - Parts Not Interchangeable. 3.4 Mercury Free - The Material Supplied Under This Contract/purchase Order Is Intended For Use On Submarines/surface Ships And Therefore Shall Contain No Metallic Mercury And Shall Be Free From Mercury Contamination. Mercury Contamination Of The Material will Be Cause For Rejection. If The Inclusion Of Metallic Mercury Is Required As A Functional Part Of The Material Furnished Under This Contract, The Contractor Shall Obtain Written Approval From The Procurement Contracting Officer Before Proceeding With Manufacture. The contractor's Request Shall Explain In Detail The Requirements For Mercury, Identify Specifically The Parts To Contain Mercury, And Explain The Method Of Protection Against Mercury Escape. Such A Request Will Be Forwarded Directly To The Procurement Contracting officer With A Copy To The Applicable Government Inspector. Upon Approval By The Contracting Officer, The Vendor Will Provide A "warning Plate" Stating That Metallic Mercury Is A Functional Part Of The Item And Will Include Name And Location Of That Part. The Use Of Mercury, Mercury Compounds, Or Mercury-bearing Instruments And/or Equipment In A Manner Which Might Cause Contamination In The Manufacture, Assembly, Or Test Of Material On This Contract Is Prohibited. The Most Probable Causes Of contamination Are Direct-connected Manometers, Mercury Vacuum Pumps, Mercury Seals, Or The Handling Of Mercury In The Immediate Vicinity. Mercury Switches, Mercury In Glass Thermometers, Standard Cells And Other Items Containing Mercury May Be Used If They Are located So As Not To Constitute A Contamination Hazard. If External Contamination By Metallic Mercury Occurs Or Is Suspected, The Following Test May Be Used To Determine Whether Contamination By Metallic Mercury Exists Or Whether Corrective Cleaning Measures Have Been Effective. Enclose The Equipment In A polyethylene Bag Or Close-fitting Airtight Container For Eight Hours At Room Temperature (70 Degrees F Minimum).sample The Trapped Air And If Mercury Vapor Concentration Is 0.01 Mg/cu Meter Or More, The Material Is Mercury Contaminated Insofar As The requirements Of This Contract Are Concerned. These Requirements Shall Be Included In Any Subcontract Or Purchase Order Hereunder And The Contractor Shall Insure Subcontractor Compliance With These Requirements. Technical Questions Pertaining To These Requirements Shall Be Referred To The Procurement Contracting Officer Via The Cognizant Administrative Contracting Officer. For Background, The Following Information Is Provided: Mercury Is Corrosive To Gold, Silver, Nickel, Stainless Steels, Aluminum And Copper Alloys. Stainless Steels, Nickel, And Copper Alloys Are Widely Used In Reactor Plants And Other Submarine/surface Ship Systems. Accidental Trapping Of Mercury In A component Could Cause Serious Damage To Vital Parts. Mercury Is Also Toxic If Inhaled, Ingested, Or Absorbed Through The Skin. It Is Evident That Grave Consequences Could Result From Small Amounts Of Mercury Vapor Present In An Unreplenished Submarine/surface ship Atmosphere. 4. Quality Assurance 4.1 Responsibility For Inspection - Unless Otherwise Specified In The Contract/purchase Order, The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified Herein. Except As Otherwise Specified In The Contract/purchase Order, the Contractor May Use His Own Or Any Other Facilities Suitable For The Performance Of The Inspection Requirements Specified Herein, Unless Disapproved By The Government. The Government Reserves The Right To Perform Any Of The Inspections Set Forth In The specification Where Such Inspections Are Deemed Necessary To Assure Supplies And Services Conform To Prescribed Requirements. 4.2 Inspection Of Item(s) Manufactured To Commercial (nongovernment) Specifications - Inspection Of The Completed Valve,gate Shall Be Limited To Type And Kind, Quantity, Condition, Packaging And Marking. 4.2.1 ; |p| Responsibility For Compliance - All Items Must Meet All Requirements Of This Contract/purchase Order. The Inspection Set Forth In This Specification Shall Become A Part Of The Contractor's Overall Inspection System Or Quality Program. The absence Of Any Inspection Requirements Shall Not Relieve The Contractor Of The Responsibility Of Assuring That All Products Or Supplies Submitted To The Government For Acceptance Comply With All Requirements Of The Contract/purchase Order. Sampling In Quality conformance Does Not Authorize Submission Of Known Defective Material, Either Indicated Or Actual, Not Doesit Commit The Government To Acceptance Of Defective Material.; 4.3 Responsibility For Compliance - All Items Must Meet All Requirements Of This Contract/purchase Order. The Inspection Set Forth In This Specification Shall Become A Part Of The Contractor's Overall Inspection System Or Quality Program. The Absence Of Any inspection Requirements Shall Not Relieve The Contractor Of The Responsibility Of Assuring That All Products Or Supplies Submitted To The Government For Acceptance Comply With All Requirements Of The Contract/purchase Order. Sampling In Quality Conformance does Not Authorize Submission Of Known Defective Material, Either Indicated Or Actual, Not Does It Commit The Government To Acceptance Of Defective Material. 4.4 Records Of Inspection - (this Requirement Is Not Applicable To Government Purchase Orders) Records Of All Inspection Work Performed By The Contractor, As Referenced Elsewhere In This Contract, Shall Be Kept Complete And Available To The Government During the Performance Of The Contract And For A Period Of Four Years After Final Delivery Of Supplies. 5. Packaging 5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Shall Be In Accordance With The Contract/purchase Order Schedule And As Specified Below. mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes 6.1 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss) (i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. Most Specifications Can Obtained Directly From Http://quicksearch.dla.mil/ a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documentsthat Are Required By Private Industry In Fulfillment Of Contractual Obligationsin Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk. b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. Theymay Be Obtained From The Publishers Of The Applicable Societies. c. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To: commander, Indian Head Division, Naval Surface Warfare Center code 8410p, 101 Strauss Avenue indian Head, Md 20640-5035 d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contractnumber, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document. e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From: contracting Officer navsup-wss code 87321 5450 Carlisle Pike p.o. Box 2020 mechanicsburg, Pa. 17055-0788 f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered Enue: commanding Officer navsup-wss code 009 5450 Carlisle Pike p.o. Box 2020 mechanicsburg, Pa. 17055-0788 g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From: commanding Officer navsup-wss code 1 Support Branch 700 Robbins Avenue philadelphia, Pa. 19111-5094 h. Interim Changes And Classified Specifications Must Be Obtained By Submitting A Request On Dd Form 1425 To Navsup-wss. 6.2 In Accordance With Opnavinst 5510.1 All Documents And Drawings Provided By The U.s. Navy To Perspective Contractors Must Include A "distribution Statement" To Inform The Contractor Of The Limits Of Distribution, And The Safeguarding Of The Information contained On Those Documents And Drawings. There Are 7 (seven) Seperate Distribution Statement Codes Used For Non-classified Documents And Drawings. The Definition For Each Is As Follows: a... Approved For Public Release; Distribution Is Unlimited. b... Distribution Authorized To Us Governments Agencies Only. c... Distribution Authorized To Us Government Agencies And Their Contractors. d... Distribution Authorized To Dod And Dod Contractors Only. e... Distribution Authorized To Dod Components Only. f... Further Distribution Only As Directed By Commander, Naval Sea Systems Command, Code 09t. x... Distribution Is Authorized To Us Government Agencies And Private Individuals Or Enterprises Eligible To Obtain Export Controlled Technical Data In Accordance With Opnavinst 5510.161. 6.3 Notice To Distributors/offerors - Consideration For Award Of Contract Shall Be Given Only To Authorized Distributors Of The Original Manufacturer's Item Represented In This Solicitation. If You Desire To Be Considered As A Potential Source For Award Of this Contract, Proof Of Being An Authorized Distributor Shall Be Provided On Company Letterhead Signed By A Responsible Company Official And Sent With Your Offer To The Procurement Contracting Officer.

U S COAST GUARD USA Tender

Machinery and Tools
United States
Closing Date11 Sep 2025
Tender AmountRefer Documents 
Description: Valve, Solenoid

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

Civil And Construction...+3Civil Works Others, Electrical and Electronics, Electrical Works
Corrigendum : Closing Date Modified
United States
Closing Date14 Mar 2025
Tender AmountRefer Documents 
Details: Schedule Of Contract Line Items And Prices/costs stl Jv Vamc Completion List Project in Accordance With The Request For Proposal, The Contract Drawings And Specifications And Amendments To Either, The Work Of Each Contract Line Item As Defined Herein In General Terms Includes, But Is Not Limited To, Provision Of All Labor, Materials, Tools, Equipment, Transportation, Management, Supervision, Quality Control And All Other Necessary Services And Performance Of All Construction Services And Incidental Related Work For Completion Of Fully Functional, Integrated And Operational Site Improvements. item No. 1: Add Electrical Power To Steam Manholes 4, 5, And 6 General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 1: $ __________________________ item No. 2: Reconnect/replace Ballard Lights At Fisher House. Investigate The Lighting Circuits And Restore The Operation Of The Exterior Bollard Lights Using New 36 Inch Tall Light Bollard And New Concrete Bases Where The Existing Bollard Are Located Around The Fisher House. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 2: $ __________________________ item No. 3: Replace Water Supply To Fisher House General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 3: $ __________________________ item No. 4: Reconnect/replace Ballard Lights At Fisher House General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 4: $ __________________________ item No. 5: Replace Watermain Dead Leg Southeast Of Building 1 And Item No. 10: Change The Direction Of The Fire Hydrant East Of The Building 53 Loading Dock General Construction: See Solicitation No. 36c10f24r0098 For Further Details. Item No. 5 & 10: $ __________________________ item No. 6: Add Toe Rail On All Handrail South Of Building 1 And Add New Handrail And Toe Rail North Of Building 56 General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 6: $ __________________________ item No. 7: Replace East Sidewalk South Of Building 1 That Does Not Meet Va Standards For Slope General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 7: $ __________________________ item No. 8: Replace Curb Islands On Either Side Of The Handicap Parking Spaces South Of Building 1 General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 8: $ __________________________ Item No. 9: Repair/regrade Asphalt Around Water Main Valve General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 9: $ __________________________ item No. 10: See Item No. 5 General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 10: $ __see Item No. 5___________ item No. 11: Clean Under Grate And Clean Silt Out Of High Voltage Electrical Manhole General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 11: $ _________________________ item No. 12: Add Photocell Pedestal Controller For B54 Exterior Lights General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 12: $ _________________________ item No. 13: Enlarge Mulch Area Or Install New Mulch Area Around Light Fixtures In The West Campus Areas General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 13: $ _________________________ item No. 14: Install New Metal Edging, Removed Existing Sod, And Install New Mulch Around Flag Pole Bases And Their Inground Light Bases General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 14: $ _________________________ item No. 15: Mill And Overlay Asphalt Pavement Approximately 660 Lf And Selectively Replace Deteriorated Concrete Curb And Gutter In This Location General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 15: $ _________________________ item No. 16: Remove Two Large Trees In The West Campus Area North Of The North Entrance Road General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 16: $ _________________________ item No. 17: Add Photocell Controller To The West Campus Area Exterior Lighting General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 17: $ _________________________ item No. 18: Provide 100 Customizable Memorial Pavers In The Existing Memorial Band Of Pavers In The West Campus Area General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 18: $ _________________________ item No. 19: Remove Vegetation Existing Aggregate Base And Install New Anti-vegetation Mat And Aggregate Base At The Top Of The Cast-in-place Retaining Wall General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 19: $ _________________________ item No. 20: Replace Existing Underground Steam Line And Condensate Lines Under The Asphalt At The Building 24 Loading Dock General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 20: $ _________________________ item No. 21: Excavate Steam Pipe Thrust Block On New Steam Manhole 5 And Steam Manhole 6, Take Compaction And Soil Bearing Measurements, Backfill And Restore Excavated Areas General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 21: $ _________________________ item No. 22: Construct Access Roadway/walkway Path To Existing Steam Manhole At The Southeast Corner Of Building 57 General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 22: $ _________________________ item No. 23: Not Used General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 23: $ ____note Used ____________ item No. 24: Install New Detector Loops And New Conduits And Restore Operations To The Building 57 Vehicle Double Gates General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 24: $ _________________________ item No. 25: Not Used General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 25: $ ____not Used _____________ item No. 26: Inside The Mechanical Room Remove Silt From The Pipe Chase Pit, Reseal The Two Steam Pipe Wall Penetrations From The Inside, Replace The Steam Pit Floor Drain Cover, Excavate The Stem Pipe Wall Penetrations From Outside Building 52 And Re-seal The Penetration From The Outside, Backfill And Restore The Excavation Area. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 26: $ _________________________ item No. 27: Add Galvanized Steel Support Brackets In The New Steam Manholes Under Each End Of The Center Lid Support Beam. Repair Concrete Where Cracked Around The Lid Center Beam Connect Points. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 27: $ _________________________ item No. 28: Replace Chilled Water Pipes In Chilled Water Pipe Manhole No. 25 Which Is North Of Building 23. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 28: $ _________________________ item No. 29: Demolish The Top Of Three Existing And Abandoned Steam Manholes To 24 Inches Below Existing Finish Grade, Abate And Remove The Steam Pipes In The Manholes To 1 Ft. Inside The Connecting Underground Pipe Chases, Fill The Openings With Cmu Block Walls, Fill The Now Empty Manhole With Clean Aggregate From The Bottom Of The Manhole To 24 Inches Below Finish Grade To Prevent Future Settlement, Backfill On Top Of The Clean Aggregate With Clean Dirt To 4 Inches Below Subgrade, Backfill With 4 Inches Of Tope Soil And Install Sod At Finish Grade. One Manhole Will Receive An Aggregate Base In Lieu Of Sod And Top Soil Where It Sets In An Existing Aggregate Parking Area. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 29: $ _________________________ item No. 30: Re-install 40 Lf Of Ornamental Railing In The West Campus Area To Correct An Alignment. The Ornamental Rail Will Be Cut Apart As Needed Raise 2=approximately 2.5 Inches And Rewelded And Repainted, Restored To Its Existing Finish. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 30: $ _________________________ item No. 31: Replace Concrete Pavement Around Light Pole At The Southeast Corner Of Building 25. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 31: $ _________________________ item No. 32: Remove Silt From Old Steam Manhole No. 3 At The Southeast Corner Of Building 75 And Add Block Enclosures Inside The Manhole To Prevent Silt From Entering The Manhole From The Connecting Underground Pipe Chases. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 32: $ _________________________ item No. 33: Replace The Inground Light Fixture At Monument Area With Matching Light Fixture Flush With The Adjacent Exposed Aggregate Finish. A Deviation In Elevation Of Greater Than 1/8 Inch Will Not Be Acceptable For The Top Of The New Inground Light Fixture. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 33: $ _________________________ item No. 34: Move Electrical Panels That Are Currently Inside The Chilled Water Manhole Side Of Manholes 13, And Inside Steam Manhole 15 From The Underground Manhole Vault To A New Exterior Electrical Panel On A New Exterior Concrete Slab. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 34: $ _________________________ item No. 35: Remove Two Existing Un-sued Light Pole Bases On The West Side Of Building 52. Remove The Concrete Base To A Depth Of 18 Inches Below Grade And Restore The Excavated Area With Clean Dirt, Topsoil And Seed And Straw. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 35: $ _________________________ item No. 36: Repair The Damaged Eifs Spots Along The South Side Of Building 1 And Repaint The Repaired Spots. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 36: $ _________________________ item No. 37: Not Used General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 37: $ _____not Used____________ item No. 38: Remove The Existing Wall Coating In The Rehab Pool And Connecting Hallway In Building 54 And Install A New Spray In Textured Wall Coating. Dye The Wall Coating To Patch The Existing Conditions Minus The Stripe Design. General Construction: See Solicitation No. 36c10f24r0098 For Further Details. item No. 38: $ _________________________ Grand Total: $_________________________

Bharat Petroleum Corporation Limited - BPCL Tender

Works
Machinery and Tools
Corrigendum : Closing Date Modified
India
Closing Soon28 Feb 2025
Tender AmountRefer Documents 
Description: Reconditioning Of Pfccu 1reconditioning Of Pfccu 14 300# Tss Bottom Valve4 300# Tss Bottom Valve

Gujarat State Electricity Corporation Limited - GSECL Tender

Works
Civil And Construction
Corrigendum : Closing Date Modified
India
Closing Soon6 Mar 2025
Tender AmountINR 8.7 Million (USD 101 K)
Description: Work Of Complete O/h Of Ms And Hrh Strainers, Hp And Ip Stop And Control Valves, Tg Bearings, H2 Seal Body, Crh And Extraction Nrv S And Mop Of 210mw Bhel Make, Kwu Design Tg Set Of Unit No 4, 5, 6 And 7 At Wtps On As And When Required Basis.

DEFENSE LOGISTICS AGENCY USA Tender

Machinery and Tools
Corrigendum : Closing Date Modified
United States
Closing Date14 Mar 2025
Tender AmountRefer Documents 
Description: Item: Valve, Linear Direct . Nsn: 4810-01-263-2541 . P/n: 731375. Qty: 73 Ea. Option: 100%. Fob: Dest. The Offer Due Date Is On Or About 13 March 2025 11:59pm Est (see Solicitation For Actual Due Date). The Solicitation Will Explain That The Drawings Are Inadequate To Enable Competitive Bidding. This Item Is Being Restricted To The Approved Source Which Is Eaton Aerospace (cage 62983) Or An Authorized Distributor. Only The Approved Sources And/or Distributors Will Be Considered On This Buy. If You Want To Become An Approved Source For Future Buys, Contact The Competition Management Office At This E-mail Address: Usarmy.detroit.tacom.mbx.lcmc-competition-management-office@mail.mil.
3591-3600 of 3739 active Tenders