Tenders of Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster
Tenders of Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster
Sorry!
No Active
Tenders of Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster
foundCheck archived
Tenders of Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster
Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster Tender
Civil And Construction...+1Others
Germany
Restricted invitation to tender with public participation competition Vob/a scaffolding work 1. The construction project involves the new extension of the fire station with 4 vehicle parking spaces and the necessary social rooms. The existing building will be partially demolished and rebuilt. For the vehicle hall, the additional base including foundations and upstands will be built using solid construction. The social wing on the ground floor and the building dividing wall to the hall will be newly built using solid construction. The upper floor of the social wing and the roof and walls of the vehicle hall will be made of wood. The "sports center" part of the existing building will be retained and in use during the construction period. Fire service access roads, the access to the construction yard (fire service location during construction) and escape and rescue routes must be kept clear throughout the entire construction phase, see appendix. Everything else must be agreed upon with the construction management, particularly exceptions. 2. During the project, some work may be carried out by construction yard employees and fire service members on their own. This may result in various items being omitted altogether or quantities in certain areas of various items being reduced. The omission or reduction in quantities of these items does not entitle the contractor to make claims for lost profits or claims for an increase in unit prices. The price inquiry or requirement items must be filled out without fail, as it is possible that these items will also be implemented. The bidder acknowledges these preliminary remarks by signing the list of services. 3. The construction site toilet and break rooms must be provided by each contractor themselves. Energy, water and electricity are provided free of charge. 4. There is a weekly construction meeting with all contractors in the community center/construction site. Company representatives who are currently working on the construction site and who will begin work in the next three weeks are required to attend and coordinate construction progress. Any costs must be included in the EPs. 5. When accepting the order, the contractor recognizes the dates stated in the preliminary remarks and the construction schedule as binding and will, if necessary, carry out necessary work outside of working hours at no extra cost so as not to jeopardize the deadlines for subsequent work. The contractor undertakes to provide the appropriate number of workers based on the amount of work and the number of working days. 6. The contractually binding partial deadlines are set out in the attached construction schedule. 7. The work advertised must be carried out in installments in accordance with the construction progress. This does not give the contractor any right to make additional demands. 8. Garbage and rubble disposal must be carried out every two days at most, in accordance with the work steps. Each contractor is responsible for this themselves. 9. All further details can be found in the list of services. 10. Services that exceed the contract amount require prior written approval; otherwise no payment will be made! Accordingly, supplementary offers must be approved in good time (at least three weeks) before execution. 11. Depending on the trade, the following documents must be enclosed with the final invoice in paper form and digitally (copied onto a CD or data carrier). These can be different documents depending on the trade. 12. Acceptance is carried out by the local construction management and the safety and health coordinator (sigeko). 13. The work is scheduled to proceed as follows: See construction schedule in the appendix - technical description of scaffolding work - assembly, modification and dismantling General The contractor responsible for the scaffolding work must ensure - that the scaffolding is assembled, modified and dismantled safely and - that the scaffolding is constructed in accordance with recognized technical standards. Scaffolding work must be led by technically qualified superiors. They must ensure that the scaffolding work is carried out in accordance with the regulations. Scaffolding work must be supervised by supervisors (sigeko). The supervisor is the person who is responsible for monitoring the execution of scaffolding work and ensuring that it is carried out safely. He must have sufficient knowledge and experience for this and be authorized to give instructions. Measures before work begins: Before scaffolding work begins, the contractor must determine whether there are any systems in the planned work area that could endanger insured persons. If the contractor accepts orders that are to be carried out at the same time and place as orders from other contractors, he is obliged to coordinate with the other contractors to the extent that this is necessary to avoid mutual danger. Electrical systems and equipment: If electrical equipment with a mains connection is used for scaffolding work, it must be operated via a special feed point in accordance with DIN VDE 0100-704. Electrical equipment includes, for example, electrically operated construction hoists and drilling machines. A special feed point is a construction power distributor in accordance with DIN VDE 0660-501 or a small construction power distributor in accordance with the "Information sheet for the construction and operation of small construction power distributors". Carrying out the work: Scaffolding components must be visually inspected for damage before installation. Damaged scaffolding components must not be installed. Scaffolding work must be carried out in such a way that the time period for activities that involve a risk of falling is as short as possible. - Scaffolding components must not be dropped. - Scaffolding components must be stored properly. Use - General: Every contractor who uses scaffolding is responsible for - using it as intended and - maintaining the operational safety of the scaffolding. He must ensure that it is not used before it is finally completed. Proof of final completion can be, for example, a handover protocol. Use: Workstations on scaffolding may only be entered and exited via safe access or access routes. Jumping off scaffolding decks or throwing anything onto them is not permitted. Putting down and storing materials and equipment is not permitted on scaffolding that is used as safety scaffolds and protective roofs. Structural changes to scaffolding may only be made by the scaffolding manufacturer. Marking: The scaffold erector must mark the scaffolding clearly after completion and for the duration of use with the following information: - DIN 4420 - Scaffolding group and working weight - Scaffold erector. Inspection - Inspection by the scaffold erector: The contractor responsible for the scaffolding work must ensure that the scaffolding is inspected - before handover to the user and - after design changes, in particular for - the perfect condition of the scaffolding components, - compliance with the standard design or - compliance with the proof of usability. Inspection by the scaffolding user: Every contractor who uses the scaffolding must ensure that the scaffolding is inspected for obvious defects before use. If defects are discovered during the inspection, the scaffolding must not be used in the areas with defects until they have been remedied. The attached "special contract conditions" are binding for the submission of offers, awarding of contracts, execution and invoicing of the work. The unit prices of the items are to be calculated as net prices, i.e. without sales tax. Sales tax is to be added after the subtotal. Alternative items are to be calculated carefully; they may be decisive for the execution and award of the order. Additional technical regulations and ancillary services Safety regulations: All work in the area of existing neighboring buildings must be carried out with the utmost care and in compliance with the relevant regulations. Components at risk must be supported as required. All work is to be carried out correctly and professionally, observing the building regulations for the protection of people working on construction sites, in conjunction with the relevant accident prevention regulations. Measurement and invoicing: All invoices submitted by the entrepreneur / contractor to the construction management must be supplemented or presented with attachments, i.e. drawings, otherwise the payment order will be delayed until the required documents have been provided. Additional services: Safety measures for the protection of buildings and for personal protection are not remunerated separately; they must be included in the unit prices.
Closing Date21 Feb 2025
Tender AmountRefer Documents
Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster Tender
Civil And Construction...+1Others
Germany
Restricted invitation to tender with public participation competition Vob/a demolition and dismantling work 1. The construction project involves the new extension of the fire station with 4 vehicle parking spaces and the necessary social rooms. The existing building will be partially demolished and rebuilt. The additional base for the vehicle hall, including the foundation and upstands, will be built using solid construction. The social wing on the ground floor and the building dividing wall to the hall will be rebuilt using solid construction. The upper floor of the social wing and the roof and walls of the vehicle hall will be made of wood. The "sports center" part of the existing building will be retained and in use during the construction period. Fire service access roads, the access to the construction yard (fire service location during construction) and escape and rescue routes must be kept clear throughout the entire construction phase, see appendix. Everything else must be agreed upon with the construction management, particularly exceptions. 2. During the project, some work may be carried out by construction yard employees and fire service members on their own. This may result in various items being omitted altogether or quantities in certain areas of various items being reduced. The omission or reduction in quantities of these items does not entitle the contractor to make claims for lost profits or claims for an increase in unit prices. The price inquiry or requirement items must be filled out without fail, as it is possible that these items will also be implemented. The bidder acknowledges these preliminary remarks by signing the list of services. 3. The construction site toilet and break rooms must be provided by each contractor themselves. Energy, water and electricity are provided free of charge. 4. Upon acceptance of the order, the contractor acknowledges the dates stated in the preliminary remarks and the construction schedule as binding and will, if necessary, carry out the necessary work outside of working hours at no extra cost so as not to jeopardise the deadlines for subsequent work. The contractor undertakes to ensure that the number of workers is adequately available based on the amount of work and the number of working days. 5. The contractually binding partial deadlines are set out in the attached construction schedule. 6. The work advertised must be carried out in installments as construction progresses. This does not entitle the contractor to make additional demands. 7. Services that exceed the order amount require prior written approval; otherwise no payment will be made! Accordingly, supplementary offers must be approved in good time (at least 3 weeks) before execution. 8. Depending on the trade, the following documents must be enclosed with the final invoice in paper form and digitally (copied onto a CD or data carrier). These can be different documents depending on the trade. 9. Acceptance A formal acceptance in accordance with the VOB is expressly agreed. Acceptance through use is excluded Acceptance requires that all services have been completed in accordance with the order letter or any subsequent order, that the necessary acceptances have taken place without any major defects and that the documentation has been submitted at least once. 10. The work is scheduled to proceed as follows: See construction schedule in the appendix Partial demolition must be carried out with appropriate caution due to the adjacent and to-be-retained existing sports hall and the neighboring buildings close to the border. Partial demolition includes the roof structure, the southern long wall, the eastern gable wall and the existing built-in features. The reinforced concrete slab in the area of the future vehicle hall will remain as-is and must be protected accordingly. In the area of the future social wing, the existing reinforced concrete slab including the strip foundations is to be removed. The flat roof between the sports hall and the fire station, including the canopy, will be retained and must be protected. The existing furnishings and the remaining waste (bulky waste) must be removed from the safely accessible areas before demolition and disposed of properly. All wooden parts from the outside area, timber framework and other construction timbers are to be sorted and disposed of as waste wood category A IV. The roof covering and the wall cladding of the gable walls and the eaves (cornices of the longitudinal walls made of fibre cement panels are to be dismantled in accordance with TRGS 519 and disposed of under the waste code number (asn) 17 06 05*. The required qualification for asbestos work in accordance with TRGS 519 is to be submitted with the offer. Mineral wool (kmf) is to be dismantled and disposed of in accordance with TRGS 521. The mineral construction waste is to be made available in heaps for disposal. The heaps are sampled on site for waste classification. Disposal may only take place after approval by the Ag/local construction monitoring. Special information on the public traffic area Access to the building is via Goethestrasse. During the demolition and dismantling work, no Complete closure of Goethestrasse is possible. The access to the directly adjacent construction yard must be kept clear at all times during the work (temporary replacement location for the fire department), see attachment. Before submitting the offer, the bidder can inform himself about the local conditions. Investigations that are due to ignorance of the local conditions will not be accepted.
Closing Date21 Feb 2025
Tender AmountRefer Documents
Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster Tender
Germany
Public tender (supply/service) Implementation of the wheel routing concept The towns of Frankenau, Gemünden (wohra) And The municipality of Haina (kloster) The following construction description Unbindings the contractor Not From the obligation to surrender to the offer Conditions In the field of constructional measures To inform and to find out More... the following construction description Unbindings the contractor Not From the obligation to surrender to the public. Conditions In the field of construction measures To inform and to learn more about the extent and the difficulty of getting work. Subject This Call Is The Road Signs For Cycling In The Communes Haina (kloster,) Frankenau And Gemünden (wohra) In the Lk Waldeck-frankenberg, Gemünden. In Hessen (Handbook Zur Radwegweisung In Hessen, Aufgestellt Vom Hess. Min. For Economics, Energy, Transport and Development) U. Der Merkblatt der Forschungsgesellschaft Für Str-. U. Verkehrswesen. The offer Includes the delivery and the placement of wheelway signs With the relative mounting devices and fastening materials. The Fix And Finishing, Professional, Performance To Turnkey Work Ready Execution The Construction Measure With All Delivery, Side Delivery, Work And Side Works According to the Performance Description, The Performance Plans, The Din Standards, The Manufacturer Rules, The Statistical Calculations and Other Opinions. The contractor (an) has the duty to inform yourself about whether in the area of the construction site lines and cables are laid. The effort for this is In The Positions of the Lv With Input And Will Not Separately Remunerated. The An Hat In The Precise Location The Existing Cables And Wires Before The Start The Construction Works By Distinguishing Supply Carriers. All To Ensure And To Protection Of Cables And Wires Required Works In the area The construction site Are Sache des An. Wire trenches (such trenches) Be not Specially Remunerated. Required expenditures In The pos. The Lv As a risk to be included. Being damaged by the An Cable O. Cables, So Going Possible damages Claims The concerned Supply Carrier, Owner O. Otherwise. All works are in principle while maintaining traffic As a rule to carry out work places of shorter duration. Traffic Control Is According to the guidelines for securing workstations to roads (rsa-95). The required traffic law arrangement Is At the Competent Road Authority 2 weeks before the start of work to request. The incurring costs The incurs. The obligation to register 5 working days before the start of the work. The signatories to be sent (director, table router U. Intermediate router) The "quality requirements On standard traffic signs For fixed signs" The Quality Protection Community Transport signs U. Transport facilities E.v. The final edge is made of metal. Plastic rails are not permissible. The design is to perform that no sharp edges are created. The intermediate signs are to be produced with rounded corners. For the additional plaques As Insert In The Arrow U. Table Ways Is The Schwalbenschwanzprofil To Use. The tables are to be produced in dissolved form. It is the traffic script According to Din 1451 middle O. Engschrift To use. The basic color is white (retroelecting film type 1 Or 2) And The font is in traffic green After Ral 6024 to be carried out. The design The directions U. Des Routelogos is given by Pages Des Ag. For the different types of signs (arrow-way sign, Table-U. Intermediate sign) Is always before the start of execution A colourful drawing With dimensions U. To make a pattern sign. Without permission, Both The Drawings As The Pattern Signs, By The Ag May The Order Not Executioned. The on-site installation is to document. Changes, The Due to the vote Bzw. While the construction design yields, are to be shown in this table. Incl. fastening material Are Gem. Ivz-morn (industrial standard For mounting devices From standard traffic signs) To deliver and place. Offer prices Understanding Packaging U. Freight Free To Use Site. Unrestricted U. Unvalued packaging materials U. Materials Transport protection must be withdrawn from An Restlos. The decrease U. Billing is carried out by Ag. In your latest valid version Unless Not Travelled In Other Place Listed: - Handbich Zur Radwegweisung In Hessen (mobiles Hessen 2020) - Verkehrsordnung (stvo) - Allgem. Administrative provisions on road traffic regulations (vwv-stvo) - Additional technical contract conditions U. Guidelines for safety work at workstations at roads (ztv-sa 97) - Din 6171 U. All relevant standards - Directive for road signs Outside of motorways Rwb, issue 2000
Closing Date24 May 2023
Tender AmountRefer Documents
Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster Tender
Others
Germany
Restricted invitation to tender with public competition Vob/a electrical installation 01.The relevant rules, guidelines and provisions in their latest version apply to the execution of the system. All VDE regulations that must be applied to this construction project. ... More01.The relevant rules, guidelines and provisions in their latest version apply to the execution of the system. All VDE regulations that must be applied to this construction project. Other relevant guidelines and regulations, such as: - The requirements of the building inspectorate - The requirements of the building regulations office - The requirements of the trade inspectorate - The requirements of the local fire brigade - The building police and official regulations - Those of the fire protection office - The recommendation of the building trade association - The guidelines and regulations of Deutsche Post AG Fo and Ftz - The specific requirements of the building permit - The accident prevention regulations - Afa - The recommendation of the office for occupational safety - Avb - Electrical regulations - Lbo - State building regulations with all partial regulations - Vdew, Zvei, Zveh - Vds - The recommendation of the association of property insurers - Tab - Technical connection conditions for medium and low voltage systems of the responsible Evu. All regulations must be conscientiously observed and followed. 02.As a general rule, only overview plans with the system devices are provided. The cable dimensions must be selected according to the system functions and special features of the manufacturer. 03.The upstream overcurrent and short-circuit devices must be adapted to the actual conditions and corrected as appropriate. The person who created the system is liable for its accuracy. Particular attention must be paid to an even load distribution across the three external conductors. The evenness must be verified by measurements. 04.The products offered that have the addition "or equivalent" serve solely to determine the technical requirements to be met by these materials. It is up to the bidder to offer other products that meet these quality standards. 05.There are no lockable rooms available on site for the accommodation of workers, the storage of materials and tools, etc. 06.If the work coincides with that of other contractors, the closest possible contact must be maintained with these companies to ensure that the work is carried out smoothly. All routings must be precisely coordinated with the companies responsible for the building services systems. 07.Samples of all essential components, particularly switches, sockets, lights, ducts, platforms, etc. must be submitted to the construction management without being asked to do so before the order is placed. The final selection is made by the construction management. 08.Before the distribution boards are built, view and sectional drawings of the planned design must be submitted to the construction management for approval. 09.The bidder undertakes to appoint an assembly manager before work begins, who will accept instructions from the construction management and the client at construction meetings and ensure that they are carried out. This assembly manager must remain the same for the entire construction period. If this contact person changes, all costs for damage or inconvenience caused to the client as a result will be deducted from the final invoice. 10.All necessary daily wage work will be billed according to the hourly rates listed in the separate appendix. If the entry is not made, the wage rate will be set by the construction management. Daily wage work will only be approved if it has been agreed with the construction management beforehand. This work may only be carried out on the instructions of the construction management. Daily wage records must be presented to the construction management daily. 11.The measurements must be carried out in a time that ensures that the work can be clearly identified. The measurements must be drawn up in order by circuit. The measurement check must be requested in good time. 12.After completion of the system, the contractor must prepare valid inventory plans with the final status of the installation. The inventory plans must contain all the necessary details such as distribution boxes, circuit designations, etc. The completeness and accuracy must be confirmed from then on by means of a stamp, signature and the inscription "inventory plan". The contractor or his representative only checks the number of plans for completeness. The inventory plans are to be delivered as follows: 2 copies in paper form, folded, in folders, laid out in color 1 copy in digital form on a data carrier All audit documents are to be handed over correctly in a professional form. Handwritten sketches or entries are not accepted! Documentation documents Structure and content of the documentation documents: Cover sheet (in transparent cover) - Project name and address - Trade name - Name and address of the executing company - Name and address of the specialist planner Table of contents (in transparent cover) - Structure according to the following specification (to be separated by index sheets) 1. General 1.1 Protocol for instruction of operating personnel 1.2 List of participants in the inventory acceptance 1.3 List of participants in the functional acceptance 2. Certificates 2.1 Approval certificates 2.2 Certificates of compliance with VDE and DIN standards 2.3 Certificate according to BGV A3 2.4 TÜV acceptance 2.5 Proof of uniform phase loading 3. Functional descriptions 3.1 Functional description of complex systems 4. Measurement reports 4.1 All measurement reports according to DIN VDE 0100, Part 610 4.2 Measurement report for antenna system 4.3 Measurement report for IT cabling 5. Operation and maintenance 5.1 Operating instructions 5.2 Maintenance instructions 6. Manufacturer documents 6.1 Manufacturer brochures (labeling of all components used) 6.2 Equipment file (contains make list and spare parts list of all components used) 7. Diagrams 7.1 Installation diagrams 7.2 Block diagrams 8. Distribution/central documents 8.1 Functional description of the system 8.2 Marshalling plans 8.3 Terminal assignment plans for distributors 9. Revision plans 9.1 Installation plans, scale 1:50, specifying all operating resources with designations in accordance with the distribution documents. An operating manual and a circuit diagram must be attached to each technical center. The diagram must show the structure, function and performance data. 13.To specify the work carried out, the architect and the contractor carry out a joint acceptance of the electrical systems. This acceptance is not a test within the meaning of the VDE regulations, but a test for completeness of the service in accordance with Vob. For this purpose, it is necessary that proof of the implementation of the tests required by VDE is kept in the form of a test report. The personnel costs for participation in acceptance tests are to be included in the unit prices. 14. Partial commissioning, earlier use or final invoice do not replace a final acceptance. This can only take place after the entire work has been completed. Defects identified during acceptance must be remedied within a period to be specified more precisely, without further notice. 15. The contractor is liable for all damage caused by non-compliance with the aforementioned offer and order conditions. He is obliged to inform himself about the other tradesmen involved in the construction and their work and to report any defects that could have an impact on the execution of his services to the construction management in writing before the electrical systems are carried out. The contractor is liable for the completeness of a system component until the final acceptance. 16. References must be included with the offer or it must be stated in a list with amounts that the bidder has already installed systems of the same or larger size several times. 17. If this proof is not included, the offer will be automatically excluded. C. Additional preliminary remarks on the electrical systems 01. Within the suspended ceilings, the cables must be properly fastened with plastic clamps or plastic holders at least every 60 cm. Cable trays are only installed where the frequency of cables justifies this. 02. All cable feedthroughs through metal parts, webs, profile rails, etc. must be provided with PVC grommets. All costs for this must be included in the unit price, as must all necessary drilling. 03. All dimensions for the arrangement of the devices, such as switches, sockets, lights, etc. must be determined with the construction management before installation. 04.Multiple sockets must be designed as a combination with combination cover plates. 05.All built-in devices, such as switches and sockets, etc. must be fastened in the device boxes with screws. Claw fastening is not permitted. 06.Particular attention must be paid to the use of flame-retardant switch boxes, switch terminal boxes and junction boxes in hollow walls, etc. All of these boxes must be calculated accordingly in the Lv, even if this is not specifically mentioned, including the creation of the installation openings. 07.The cables for the building services trades, RWA systems, etc. must be laid according to the instructions of the specialist companies. A cable dimension and position plan must be requested from the specialist companies at an early stage so that these cables can be laid as part of the overall installation. 08.Socket holes in exposed brickwork must be milled cleanly in coordination with the construction management. Damage is the responsibility of the person responsible. 09.All electrical cables must be flame-retardantly coated or sheathed. Only cables from certain brands that have a test certificate for these properties may be used. The bidder must provide proof and present it without being asked to do so before installation begins. If this is neglected or if cables are not laid accordingly, the bidder must bear all costs for replacing the cables. 10.As required by the local fire protection officer, the fire brigade, the city or the relevant authority, appropriate fire barriers must be installed for breakthroughs and cable routes as a fire protection measure. Acceptance must be arranged with the fire protection officer in good time before the ceilings are closed. An acceptance certificate must be presented to the construction management without being asked to do so. All costs for this must be included in the unit prices. 11.The current MLAR must be taken into account. 12. All cable trays, risers and cable ducts must be designed with appropriate dividers to accommodate both high and low voltage systems. 13. In schools, all switches and sockets must be fitted with screwed covers in accordance with school building guidelines. 14. E30 and E90 cables may only be laid using type-approved, tested fastening material for individual installation and with appropriately approved cable tray systems for collective installation. 15. All sockets must be clearly and permanently marked with circuit numbers on the support frame. For surface-mounted sockets, the marking must be attached to the housing using a labelling device. 16. All requirements for the electrical installation listed in the preliminary remarks must be included in the EPs. There is no separate remuneration for this service. Since there are dependencies between the trades, instructions for the completion of services which are, for example, mandatory requirements for the start of a subsequent trade, must be implemented immediately. Any short-term changes to the construction process must be followed immediately. Flexible action with fast reaction times and short arrival and departure times is essential for this construction project. In view of the short execution time, this also applies to instructions from the construction management to carry out work at short notice in order not to hinder or delay subsequent trades and the overall construction process. Any additional work resulting from this must be included in the unit prices. D. General information on the service description Each item shown is to be understood as a finished job and as a service that complies with the regulations, is properly crafted and is ready for use and operation, including all ancillary services. - Additional technical contract conditions - Electrical installation DIN 18 382 The general technical regulations (ATV) for construction work of the Vob, Part C, become part of the contract. Measurements and quantity compilations as the basis for calculation are only to be prepared on forms from the engineering office. The forms are provided free of charge and must be requested in good time. The presence of a contractor employee with technical and local knowledge during the acceptance of the high and low current technical systems, in accordance with the construction certificate and the applicable building inspection regulations, by a building inspector-approved expert, is covered by the unit prices. The contractor must coordinate the provision of his services with - previous and subsequent - trades that technically affect his own services, so that his own services and his own execution dates are carried out correctly in terms of the detailed execution steps and functional accuracy. The usual work sequences, technical dependencies and individual steps of partial services that are separated in time are taken into account in the offer calculation. - General description of the measure - 1. The construction measure is the extension of the fire station with 4 vehicle parking spaces and the required social rooms. The existing building will be partially demolished and rebuilt. For the vehicle hall, the additional base, including the foundation and upstands, will be built using solid construction. The social wing on the ground floor and the building dividing wall to the hall will be rebuilt using solid construction. The upper floor of the social wing and the roof and walls of the vehicle hall will be made of wood. The "sports center" part of the existing building will be retained and in use during the construction period. Fire service access roads, the access to the depot (the fire service's location during construction) and escape and rescue routes must be kept clear throughout the entire construction phase, see attachment. Everything else, especially exceptions, must be agreed with the construction management. 2. During the project, some work may be carried out by municipal yard employees and firefighters themselves. This may result in various items being omitted altogether or quantities in parts of various items being reduced. The omission or reduction in quantities of these items does not entitle the contractor to make claims for lost profits or claims for an increase in unit prices. The price inquiry or requirement items must be filled in without fail, as it is possible that these items will also be carried out. The bidder acknowledges these preliminary remarks by signing the list of services. 3. The material costs and wage cost components requested in the individual items must be filled in without fail. Reference is made to the Vob/a (§25 ff). Here, if various items are omitted, the order may also be for the delivery of the material alone. 4. The construction site toilet and the break rooms must be provided by each contractor. Energy, water and electricity are provided free of charge. 5. A construction meeting is held weekly with all contractors in the community center/construction site. The company representatives who are currently working on the construction site and who will begin work in the next three weeks are required to attend and coordinate construction progress. Any costs must be included in the EPs. 6. Upon acceptance of the order, the contractor recognizes the dates stated in the preliminary remarks and the construction schedule as binding and will, if necessary, carry out necessary work outside of working hours at no extra cost so as not to jeopardize the deadlines for subsequent work. The contractor undertakes to provide the appropriate number of workers based on the amount of work and working days. 7. The contractually binding partial deadlines are set out in the construction schedule. 8.The work advertised must be carried out in parts in accordance with the progress of the construction. This does not give the contractor any right to make additional claims. 9.The disposal of rubbish and debris must be carried out every two days at most, analogous to the work steps. Each contractor is responsible for this himself. 10.All further details can be found in the list of services. 11.Contrary to DIN 1961 Vob Part B § 13 (4), the limitation period for claims for defects is set at five years. 12.Services that exceed the contract amount require prior written approval, otherwise no payment will be made! Accordingly, supplementary offers must be approved in good time (at least three weeks) before execution. 13.Daily construction reports must be kept. The forms from "Zweckform - Daily Construction Reports No. 177" or equivalent must be used as a template. These must be presented to the construction supervisor every 2-3 days for signature and countersignature. The work carried out, the number of workers and the hours worked must be entered here. 14. Depending on the trade, all inventory and inspection documents must be enclosed with the final invoice in duplicate in paper form and digitally (copied onto a CD or data storage device): Final payment will only be approved after the documents have been submitted. 15. By signing the list of services, the bidder acknowledges these preliminary remarks.
Closing Date21 Feb 2025
Tender AmountRefer Documents
Offizielle Bezeichnung Gemeindevorstand Der Gemeinde Haina Kloster Tender
Civil And Construction...+1Others
Germany
Restricted invitation to tender with public participation competition Vob/a solid construction work 1. The construction project involves the new extension of the fire station with 4 vehicle parking spaces and the necessary social rooms. The existing building will be partially demolished and ... More1. The construction project involves the new extension of the fire station with 4 vehicle parking spaces and the necessary social rooms. The existing building will be partially demolished and rebuilt. For the vehicle hall, the additional base including foundations and upstands will be built using solid construction. The social wing on the ground floor and the building dividing wall to the hall will be newly built using solid construction. The upper floor of the social wing and the roof and walls of the vehicle hall will be made of wood. The "sports center" part of the existing building will be retained and in use during the construction period. Fire brigade access roads, the access to the building yard (fire brigade location during construction) and escape and rescue routes must be kept clear throughout the entire construction phase, see appendix. Everything else must be agreed upon with the construction management, particularly exceptions. 2. During the project, some work may be carried out by building yard employees and fire brigade members on their own. This may result in various items being eliminated altogether or quantities in parts of various items being reduced. The elimination or reduction in quantities of these items does not entitle the contractor to make claims for lost profits or claims for an increase in unit prices. The price request and required items must be filled out without fail, as it is possible that these items will also be implemented. The bidder acknowledges these preliminary remarks by signing the list of services. 3. The construction site toilet and break rooms must be provided by each contractor themselves. Energy, water and electricity are provided free of charge. 4.The following additional services are covered by the unit prices: - Participation in construction meetings by an authorized person; if necessary - Documentation services in accordance with the general terms and conditions of the contract - Participation in expert acceptances, if necessary 5.When accepting the order, the contractor recognizes the dates stated in the preliminary remarks and the construction schedule as binding and will, if necessary, also carry out necessary work outside of working hours at no extra cost in order not to jeopardize the deadlines for subsequent work. He undertakes to keep the number of workers available accordingly according to the amount of work and working days. 6.The contractually binding partial deadlines are set out in the attached construction schedule. 7.The work advertised must be carried out in partial services in accordance with the construction progress. This does not give the contractor any right to assert additional claims. 8. Garbage and rubble disposal must be carried out every 2 days at most, in the same way as the work steps. Each contractor is responsible for this himself. 9. All other details can be found in the list of services. 10. Contrary to DIN 1961 Vob Part B § 13 (4), the limitation period for claims for defects is set at 5 years. 11. Services that exceed the contract amount require prior written approval - otherwise no payment will be made! Accordingly, supplementary offers must be approved in good time (at least 3 weeks) before execution. 12. Daily construction reports must be kept. The forms from "zweckform - daily construction reports no. 177" or an equivalent must be used as a template. These must be presented to the construction supervisor every 2-3 days for signature and countersignature. The work carried out, the number of workers and the hours worked must be entered here. 13. Depending on the trade, the following documents must be enclosed with the final invoice in paper form and digitally (copied onto a CD or data carrier). These documents can vary depending on the trade. 1. Inventory plans for newly laid cables and connections with entries for basic and height dimensions as well as details of cable cross-sections, etc. 2. Working plans 3. Inventory plans 4. Building materials list for components with manufacturer, type, type number, colour, colour number, installation location 5. Fittings list for each movable part, otherwise as above 6. Pane sizes for windows, doors, etc., otherwise as above 7. General building approval for building materials 8. Certificates of conformity for products with list of each installation location, such as room names/numbers Final payment approval will only be given after the documents required have been submitted. 14. Acceptance A formal acceptance according to the Vob is expressly agreed. Acceptance through use is excluded. Acceptance requires that all services have been provided in accordance with the order letter or any subsequent order, the necessary acceptances have taken place without any significant defects and the documentation has been submitted at least once. 15. The work is scheduled to proceed as follows: See construction schedule in the appendix
Closing Date21 Feb 2025
Tender AmountRefer Documents