Mask Tenders

Mask Tenders

The City Government Of Baguio Tender

Telecommunication Services
Philippines
Closing Date10 Jan 2025
Tender AmountPHP 2.2 Million (USD 37.9 K)
Details: Description Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 1 Lot Communications Equipment 2,200,000.00 6 Unit Base Radio, Ntc-type Approved Equipment, 136-174 Mhz Frequency Range, 50 Watts Maximum Output Power, Programmable To Ntc Assigned Frequency Specifications General A. Frequency Range - Uhf: 400-470mhz*; Vhf:136-174mhz B. Channel Capacity- 48 (16 Channels Per Zone) C. Zone Capacity - 3 D. Channel Spacing - 12.5/25khz E. Operating Voltage - 13.6 V ± 15% F. Current Drain - Standby: Around 0.3a Receive: < 1>1ghz G. Weight - 1100g H. Dimensions - 164 X 43 X150 Mm I. Frequency Stability - ±0.5 Ppm J. Antenna Impedance - 50ω Receiver A. Sensitivity - Analog: 0.3µv (12db Sinad); 0.22µv (typical) (12db Sinad); 0.4µv (20db Sinad) Digital: 0.3µv/bers5% B. Selectivity - Tia-603: 60db @ 12.5khz/ 70db @ 25khz Etsi: 60db @ 12.5khz/ 70db @ 25khz C. Intermodulation - Tia-603: 70db @ 12.5/25khz Etsi: 65db @ 12.5/25khz D. Spurious Response Rejection- Tia-603: 70db @ 12.5/25khz Etsi: 70db @ 12.5/25khz E. Blocking- Tia-603: 90db Etsi: 84db E. Hum And Noise- 40db @ 12.5khz; 45db @ 25khz F. Rated Audio Power Output- Internal (@ 16 Ohm Load): 4w External (@8 Ohm Load): 8w Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 1 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) G. Max Audio Power Output - Internal (@16 Ohm Load): 6w External (@ 8ohm Load): 12w H. Rated Audio Distortion - ≤3% I. Audio Response - +1~-3db J. Conducted Spurious Emission - <-57dbm Transmitter A. Rf Power Output – Low Power Version: 1-25w (uhf/vhf) High Power Version: 5-45w (uhf) / 5-50w (vhf) B. Fm Modulation – 11kof3e @ 12.5khz; 16k0fe @ 25 Khz’ C. 4fsk Digital Modulation – 12.5khz Data Only: 7k60fxd 12.5khz Data & Voice:7k60fxw D. Conducted/radiated Emission - -36dbm<1ghz>1ghz E. Modulation Limiting- ±205khz @ 12.5khz F. Fm Hum & Noise- 40db @ 12.5khz 45db @ 25khz G. Adjacent Channel Power- 60db @ 12.5khz; 70db @ 25khz’ H. Audio Response- +1 ~ -3db I. Audio Distortion- ≤3% J. Digital Vocoder Type- Ambe+2™ Or Selp K. Digital Protocol- Etsi-tsi02 361-1, -2, -3 1 Lot Engineering Plans And Services (professional Fee) 30 Unit Handheld Radio (vhf), Ntc Type Approved Equipment, 136-174mhz Frequency Range, 5 Watts' Maximum Out-put Power, Programmable To Ntc Award Frequency. Accessories: 1. Belt Clip 2. Standard Desk Charger 3. Rubber Duck Antenna 4. Manual General: A. Frequency Range- Uhf: 400-470 Mhz, Vhf:136-174mhz B. Channel Capacity - 128 C. Zone Capacity - 8 D. Zone Channel - 16 E. Channel Spacing - 12.5khz/20kh/25khz F. Operating Voltage -7.4v G. Battery - 1500mah (standard); 2000mah (optional) H. Battery Life - (5/5/90 Duty Cycle, High Tx Power) - Analog: 12h (1500mah), 16h (2000mah) - Digital: 16h (1500mah), 21h (2000mah) I. Frequency Stability - ±0.5ppm J. Antennal Impedance - 50ω K. Weight (with Antenna & Battery) -230g L. Dimensions (h X W X D) - 115 X 55 X 295mm M. Display - 1.77 Inch Tft Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 2 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) Receiver: A. Sensitivity - Digital: 0.18µv / Bers % Analog: 0.18µv(12db Sinad) B. Adjacent Channel Selectivity - Tia -603: 60db@12.5khz, 70db@20/25khz Etsi: 60db@12.5khz, 70db@20/25khz C. Intermodulation- Tia- 603:70db@12.5/20/25khz Etsi: 65db@12.5/20/25khz D.spurious Response Rejection- Tia -603: 70db@ 12.5/20/25khz Etsi: 70db@12.5/20/25khz E. Blocking - Tia -603:80db Etsi: 84db F. Hum And Noise- 40db@20khz, 45db@25khz G. Rated Audio Power Output - 1w H. Rated Audio Distortion - <3>1ghz E. Modulation Limiting - +2.5khz@12.5khz, +4.0khz@20khz, 15.0khz@25khz F. Fm Hum&noise - 40db@12.5khz, 43db@20khz, 45db@25khz G. Adjacent Channel Power- 60db@12.5khz, 70db@20/25khz H. Audio Response- +1 To -3db I. Audio Distorted - ≤% J. Digital Vocoder Type - Ambe +2™ Environmental: A. Operating Temperature - -30°~+60°c B. Storage Temperature - -40°c~+85°c C. Esd - Iec 61000-4.2 (level 4) ±8kv (contact); ±15kv(air) D. Dust And Water Intrusion - Iec60529-ip54 E. Humidity - Mil -std-810g F. Shock And Vibration - Mil-std-810g 1 Lot Installation Of Communication Equipment 1 Unit Mini Duplexer (vhf) -tuned To Working Frequency, 50 Watts 7 Unit Mobile Radio (vhf) - Ntc-approved Type (commercial), 50w, Programmable To Ntc Assigned Frequency Frequency Range 136-174 Mhz, With Magnetic Mount Mobile Antenna 6 Lot Ntc Permit To Purchase/possess And Radio Station License 6 (six) Units Base Radio 30 Lot Ntc Permit To Purchase/possess And Radio Station License For 30 (thirty) Units Handheld Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 3 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 Lot Ntc Permit To Purchase/possess And Radio Station License For 1 (one) Unit Repeater 7 Lot Ntc Permit To Purchase/possess And Radio Station License For 7 (seven) Mobile Radio 1 Lot Programming, Commissioning/propagation And Testing And Delivery (30 Days) Additional Requirements: * Provide A Network Diagram That Is Applicable To The Area * With History/experience In The Installation Of A Working Communication System In The Area *accredited With Ntc-car 1 Unit Repeater (vhf), Ntc-type Approved Equipment, 136-174 Mhz Frequency Range, 50 Watts Maximum Output Power, Programmable To Ntc Assigned Frequency. Specifications: General A. Frequency Range - Uhf 1: 400-470mhz; Uhf 2: 450-520mhz; Uhf 3: 350-400mhz; Vhf: 136-174 Mhz B. Channel Capacity - 16 C. Channel Spacing - 12.5khz/20khz/25 Khz D. Operating Voltage - 13.6v±15% E. Current Drain - Standby: ≤0.8a; Transmit:≤11a F. Frequency Stability - ± O.5ppm G. Antenna Impedance - 50ω H. Duty Cycle - 100% I. Dimensions (h X W X D) - 88 X 483 X 366 Mm J. Weight - 8.5 Kg K. Lcd Display - 220 X 176 Pixels, 262000 Colors; 2.0 Inch, 4 Rows Receiver A. Sensitivity - Analog: 0.28µv (12 Db Sinad); 0.22µv (typical) 12db Sinad) 0.4 Μv (20db Sinad) Digital: 0.3µv/ber5% B. Adjacent Channel Selectivity- Tia-603: 65db @ 12.5 Khz; 75 Db @20/25khz Etsi: 65 Db @ 12.5 Khz; 75 Db @ 20/25khz C. Intermodulation- Tia -603: 75db @ 12.5/20/25khz Etsi: 70db @ 12.5/20/25khz D. Spurious Response Rejection Tia-603: 80db @ 12.5/20/25khz Etsi: 80db @ 12.5/20/25khz E. Hum And Noise - 40db@ 12.5khz; 43db@20khz; 45db@25khz F. Rated Audio Power Output - 0.5w G. Rated Audio Distortion- ≤3% H. Audio Response - +1 ~ -3db I. Conducted Spurious Emission - <-57dbm Transmitter Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 4 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) A. Rf Power Output - 5-50w B. Fm Modulation - 11k0f3e @ 12.5khz; 14k0f3e @ 20khz; 16k0f3e @ 25 Khz C. 45sk Digital Modulation - 12.5khz Data Only: 7k60fxd; 12.5khz Data And Voice:7k60fxw D. Conducted/radiated Emission - -36dbm ≤ 1ghz; -30dbm > 1ghz E. Modulation Limiting - ±2.5khz @ 12.5 Khz; ±4.0khz @ 20khz; ±5.0khz @ 25khz F. Fm Hum & Noise - 40db @ 12.5khz; 43db @ 20khz; 45db @ 25khz G. Adjacent Channel Power - 60db @ 12.5khz; 70db @ 20/25khz H. Audio Response - +1 ~ -3db I. Audio Distortion - ≤3% J. Digital Vocoder Type - Ambe +2™, Selp, Nvoc, Comm K. Digital Protocol - Etsi-ts102 361-1, -2-, -3 Environmental Specifications A. Operating Temperature - -30°c ~+60°c B. Storage Temperature - -40°c ~ +85°c Accessories: 1. 1 Unit Tx Antenna (2 Elements Of Variloop Antenna) Cut, Fold And Tuned To Ntc Tx Assigned Frequency 2. 1 Unit Rx Antenna (2 Elements Of Variloop Antenna) Cut, Fold And Tuned To Ntc Tx Frequency 3. 100 M Coax Cable Rg-8 (japan) 4. 4 Pcs. Pi-259 Connector (good Quality) 5. Regulated Power Supply (13.8 V Dc/30 Amp) 6. With Pt Mask Antenna And Repeater Cabinet This Is A Lot Bidding, Partial Bids Are Not Allowed Please Indicate Brands Of Offers And Attach Technical Brochures In The Eligibility And Technical Proposal Please Indicate Unit Prices Of Offers In The Financial Proposal Bidders Must Possess Valid Mayor's/business Permit With A Relevant Line Of Business In The Supply, Delivery And Installation Of Communications Equipment For Use Of Bfp Under Pr No. 2 Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 5 Of 5

Municipality Of Mercedes, Camarines Norte Tender

Solar Installation and Products...+1Electrical and Electronics
Philippines
Closing Date6 Jan 2025
Tender AmountPHP 2.7 Million (USD 46.9 K)
Details: Description Republic Of The Philippines Province Of Camarines Norte Municipality Of Mercedes Bids And Awards Committee Bids And Awards Committee Office, Lgu - Mercedes, Camarines Norte Invitation To Bid For Purchase Of Various Supplies/materials And Equipment, Livelihood Program: Providing Resources For Opportunities And Prosperity Through Empowerment In Lgu-mercedes, Camarines Norte. The Local Government Unit Of Mercedes, Camarines Norte, Through The Trust Fund Intends To Apply The Sum Of Two Million Seven Hundred Twenty-five Thousand Two Hundred Sixty-six Pesos Only (php2,725,266.00) Being The Approved Budget For The Contract (abc) To Payments Under The Contract For The Purchase Of Various Supplies/materials And Equipment, Livelihood Program: Providing Resources For Opportunities And Prosperity Through Empowerment In Lgu-mercedes, Camarines Norte - Identification Number 401-24-11-1495/1496/1497/1498/1499. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 1. The Local Government Unit Of Mercedes, Camarines Norte, Now Invites Bids For The Purchase Of Various Supplies/materials And Equipment, Livelihood Program: Providing Resources For Opportunities And Prosperity Through Empowerment In Lgu-mercedes, Camarines Norte As Follows: Item No. Qty Unit Description Lot 1 - Hardware Tools 1 1 Unit Air Compressor Machine, Motor: 1/2 Hp; No. Of Cylinder: 2; Phase: 1; Pressure: 85 Psi; Capacity 46 Liters; Approximate Dimension: 95-100cm (l) X 31-35cm (w) X 64-70cm (h); Weight: 47kg; Inflation Time: 53min; Air Displacement: 208l/min 2 1 Unit Air Spray Gun, Standard Nozzle:1.4mm, Pattern Width:180-250mm, Paint Capacity:600cc, Suitable For Finishing Coat, Optional Nozzle:1.3-2.5mm, Operating Pressure:2-3.5bar Air Cons:4.2-7.1cfm(119-200l/min)" 3 11 Set Angle Grinder Cutting Disk, 10 Pcs.per Set; Dimensions: Approx. 105mm (4") X 1.2mm (3/64"') X 16mm (5/8") 4 11 Unit Angle Grinder, Rated Input Power: 730w; Wheel Diameter: 4"; Rated Voltage: 220v; Frequency: 60hz; No Load Speed: 12,000 Rpm; Weight: Approximately 1.6kg; Grinding Spindle Thread: M10; Disc Diameter: 100mm X 1 X 16mm, Dimension: 298mm (l), 77mm (w), 102mm (h) 5 7 Pc Chipping Hammer, Item Weight: ‎atleast 13.8 Ounces; Product Dimensions: ‎11" (l) X 1" (w) X 7.5" (h); Material:, Genuine Leather Grip And Forged Steel 6 3 Set Circular Saw With Diamond Blade, 1400w, 185 Mm Blade, Spindle Lock With 24t Diamond Blade 7 3 Pc Claw Hammer, Head Weight: 16oz; Overall Weight: 17oz-23oz; Forged Steel Head; Smooth Face; Fiberglass Handle With Rubber Cushion; Overall Length: 12-14" 8 3 Pc Concrete Chisel, 10'' Forged Steel Chisel 9 3 Pc Crow Bar, 36" Long; Length Tolerance: +- 1/8; Forged Steel Carbon 10 1 Pc Electric Planer; Voltage: 220-240v; Input Power: 1050w; No Load Speed: 1600rpm; Planing Width And Depth: 82x3mm; Heavy Duty Aluminum Base; 11 1 Pc Framing Hammer, Handle Material: Alloy Steel; Item Dimensions: Approximately 16-17" (l) X 5.75-6" (w) X 1.5-2" (h); Item Weight: Atleast 1.4 Pounds 12 1 Unit Gasoline Marine 7hp Speed Type, Single Cylinder; 4 Stroke, Forced Air Cooling; Ohv Displacement (cc): 196 Compression Ratio: 8.5:1 Bore X Stroke (mm): 68x54 Min. Fuel Consumption;395/(kw.h) Valve Clearance: Input Valve: 0.10-0.15mm Idle Speed (rpm): 1400+-140 Max A.c. Output/rpm:3.8/3600 Noise Level:70db (a) Ignition System: Transistorize Magento Ignition Max Torque (n.m/rpm): 10.7/300 Starting System: Recoil Start (recoil Start/electric Starting) 13 10 Pc Hacksaw With Blade, Adjustable Aluminun Alloy Frame With Soft-grip Handle, 90" Adjustable Bladec Angle, 12 Inches (+/- 1/4") Bi-metal Hacksaw Blade, 24 Tpi 14 10 Unit Heavy Duty Corded Drill, Rated Input Power: 750w; Chuck Capacity: Upto 13mm; Drill Capacity: Metal (16mm), Wood (25mm), Masonry (12mm); Dimension: 268mm (l) X 69mm (w) X 192mm (h); Weight W/out Cable: Approximately 1.6-1.8 Kg; Spindle Collar Diameter Of 43 Mm 15 1 Pc Level, Box Beam Style, Material: Alluminum; Dimension: Approximately 24-24.5" (l) X 2-2.6" (w) X 1.2-1.5" (h); Weight: Atleast 0.8 Pounds 16 3 Pc Mashing Hammer, 3 Lb With Fiberglass Handle, Forged Steel Head 17 3 Pc Masonry Hammer, 800g Solid Rubber Head, Fiberglass Core And Bi-material Slip-resistant Handle, 18 3 Pc Masonry Hand Saw, 15" 380mm Carbon Steel 19 3 Pc Masonry Square, 24"x 16"aluminum, 1/8 '' Thick 20 3 Pc Mason's Level, 60cm Aluminum Reinforced Frame 21 3 Tube Mason's Line, #18 Braided Nylon, 500 Ft, 170 Lb Test 22 10 Set Metal Drill Bit Set, Material: High Speed Steel; 19pcs Per Set (1mm,1.5mm,2mm,2.5mm,3mm,3.5mm,4mm,4.5mm,5mm,5.5mm,6mm,6.5mm,7mm,7.5mm,8mm,8.5mm,9mm,9.5mm,10mm); Point Angle:118degree C; Standards: Din 338; Bit Geometry: Standard Twist Bit 23 8 Pc Meter Tape With Magnetic Hook, Blade Material: Nylon Coated Blade; Dimensions: 16ft (l) X 25mm (w) 24 7 Pc Mig Welding Pliers, Overall Length: Atleast 210mm; Material: High Carbon Steel; Handle Material: Thermoplastic Rubber 25 1 Unit Portable Hand Drill, Power Sourced: Battery Powered - 2pc 21 Volt 1500mah Lithium-ion Batteries; Maximum Rotational Speed: 1500 Rpm; Voltage: 21v; Amperage: 1.5 Amps; Chuck Size: 0.38"; Bit Heads Diameters: From 0.8mm - 10mm; Product Dimensions: ‎9.6" (l) X 2.1" (w) X 7.5" (h); Material: ‎plastic, Rubber, Metal; Item Dimensions: Approx. ‎9.6" (l) X 2.1" (w) X 7.5" (h); Item Weight: Atleast ‎2.5 Pounds; Item Torque: 330 Inch Pounds; Inclusions: 1x21 Volt Inspiritech Cordless Power Drill, 2x Rechargeable Battery, 1x English User Manual, 10x Self-drilling Drywall Anchors,10x Screwdriver Bits, 2x Double Ended Bits, 3x Drilling Bits, 1x Magnetic Extension Socket Bit Holder, 10x Anchors With Screws,1x One-hour Fast Charger, 1x Flexible Extension Shaft, 1x Carrying Bag 26 7 Unit Portable Welding Machine, Input Voltage: 220-240; Frequency: 50-60hz; Output Current: 10-220a; Led Display; No-load Voltage: 85v; Max. Output Current: 220a; Diameter Of Electrode: 1.6-3.2mm; Inclusions: 1 Pc Electrode Holder, 1 Pc Earth Clamp With Cable, 27 3 Pc Pull-push Rule, Blade Length 8m/26ft, Blade Width 1", High Impact Abs Case With Durable Rubber, Corrosion Resistant Tru-zero End 28 3 Pc Putty Knife, 3" Stainless Steel With Rubber Handle 29 1 Pc Roofing Hammer: Item Weight: ‎1.25 Pounds; Product Dimensions: Approx. 13.7" (l) X 6.75" (w) X 1.5" (h) 30 1 Unit Sander, Item Dimensions: Approx 11.63" (l) X 5.63" (w) X 6.19" (h); Voltage: 110 Volts; Power Source: Corded Electric; Amperage Capacity:‎ 8.8 Amps; Variable Speed Control Dial (690 -1,440 Ft./min.); Grit Number: 80; Item Weight: Atleast ‎9.5 Pounds; Included Components: ‎belt Sander, 1 Belt, Dust Bag 31 3 Pc Shovel, Rectangular End, Tempered Steel Blade (0.8mm Gauge Orv Higher), 17-23 Cm Blade Tip Width,22-28cm Blade Tip Lenght, All Metal Handle, Overall Lenght 100cm-115 Cm 32 3 Pc Shovel, Round End, Tempered Steel Blade (0.8mm Gauge Orv Higher), 17-23 Cm Blade Tip Width,22-28cm Blade Tip Lenght, All Metal Handle, Overall Lenght 100cm-115 Cm 33 1 Pc Speed Square, Material: Cast Aluminum; Size: About 18x18x2cm/7.09x7.09x0.79"; Weight: About 130g; Triangle-shaped 34 3 Pc Spirit Level Bar, Aluminum Frame With Magnet, Size 12" (+-1/8"), With 3 Vials (horizontal, Vertical And 45 Degrees) 35 3 Pc Steel Float/plastering Trowel, Thickness 0.7 Mm, Surface Measurement 280mm X 125 Mm(+/- 1mm), High Carbon Steel, Soliod Forged Steel With Plastic Handle 36 1 Pc Trim Hammer, Handle Material: Wood; Head Material: Alloy Steel; Item Dimensions Approximately: 14-15" (l) X 5-6"(w) X 1-2" (h); Item Weight: Atleast 594 Grams 37 3 Pc Trowel, 280x120mm Stainless Plastering Trowel With Plastic Handle 38 1 Pc Utility Knife, Handle Material: Aluminum; Material: Aluminum Alloy; Weight: 120g/pcs; Blade Size: 19mm (w) X 61mm (h) X 0.6mm (t); Blade Material: Steel; Thickness: Atleast 0.6mm 39 7 Pc Welding Helmet, Auto Darkening Helmet, Power Supply: Battery And Solar Powered; Light Shade: Din9-1;, Dark Shade: Din4; Switching Time: 1/25000s; Delay Time: 0.1-0.8s; Sensitivity Adjustment: Stepless Control; Operation Temperature: -5 Degrees- 55 Degrees; Active Viewing Area: 93mmx43mm; Active Viewing Area Size: (+/- 10mm); Item Weight: Atleast 1.85 Pounds; Package Dimensions: ‎approximately 12-12.4" (l) X 9-9.61" (w) X 7-7.68" (h) 40 7 Set Welding Magnets, 6 Pcs/set, Overall Length: Atleast (3"); Hold Capacity: Up To 25lbs; Arrow Design Supports Angle: 45°, 90°, And 135°; Item Weight: 295g; Package Dimensions: ‎4.88 X 4.72 X 3.98 Inches; ‎material: Steel; Magnets Size: Approximately - Top (1-1.4cm), Bottom (6.5-7cm), Side (7-7.5cm) Thickness (1-1.3cm) 41 1 Set Wood Chisel; 4-piece Set (6mm; 12mm; 19m; 25mm); Tempered Chrome Carbon Steel Blade; Hardened Shank; Rust-resistant, Lacquered Coated Blade; Bi-material Handle 42 3 Pc Wooden Float, 18"x 32", Multi-layered Lot 2 - Food Preparation 1 1 Unit 3 In 1 Burger Griller With Deep Fryer And Steamer, Gas Type; Made Of Stainless Steel And Polished Metal Griddle Plate; Dimensions: Burger Griddle - 18" (l) X 12" (w); Deep Fryer - 8" (l) X 12" (w), Capacity: 2.5 L; Steamer: 11" (l) X 12" (w) 2 6 Unit Barbeque Grill With Sauce Holder And Top Grill, Material: Stainless Steel, Dimension(lwh): 24 In X 12 In X 30 In (3.5 In Grill Pan's Depth) 3 33 Pc Basin; Stainless; Diameter: 22"; Base: 16"; Depth: 7"; Thickness: 1cm 4 47 Pc Beach Umbrella; Round-shaped; Material: Poly Canvass; Diameter: 40""; Pole Stand Length: At Least 45""; Pole Material: Stainless Steel Chrome" 5 6 Pc Boiler Caldero; Big Size & Heavy Duty; Size: Diameter 48cm; Height: 42cm; Makapal, Material: Aluminum 6 6 Pc Boning Knife, 27.3cm, Blade Length:14.6cm, Blade Thickness: 4mm, Wood Handle 7 32 Pc Butcher's Knife; Materials: Stainless; Wood Handle; Size: About 10" 8 29 Pc Caldero With Double Handle; Aluminum Material; Diameter: 46cm; Height: 37cm; With Double Handle; Capacity 5kilos/20l(volume Capacity) 9 48 Set Casserole Set, Stainless Steel, 28, 30 And 32cm Diameter; 16, 18, 20cm Height 10 50 Pc Chef's Knife; About 10 3/4" Long; Material: Stainless Steel; Blade: Full Tang; Riveted Handle 11 56 Pc Chest Cooler, Item Package Dimensions: ‎25.8" (l) X 16.2" (w) X 15.7" (h), Package Weight: ‎5.76kg, Inside Dimensions: 24.95" (l) X 14.58" (w) X 14.77" (h), Material: ‎plastic, Chamber Depth: 24.95", Capacity: 52l, Color: Any Color 12 51 Pc Chopping Board; Thick Wood; 12"x12" 13 6 Pc Cleaver Knife, 11" Stainless Steel, Weight: 310-340g, Blade Size: 6.5 Inches 14 48 Pc Colander; Stainless Steel; 11"diameter; With Stainless Base And Handle 15 6 Unit Digital Weighing Scale ,30kg Capacity,stainless Tray Size: 35x23cm For 30kg Capacity Weighing Scale, Dual - Display : Weight, Unit Price, Amount, High Light Led Display, Rechargeable Battery, Power Supply: Ac/dc Charger (included) 16 47 Unit Double Burner Gas Stove; Stainless Top And Front; Automatic Ignition; Reversible Trivet; Double Detachable Top Burner; Removable Drip Pan; Dimension: 700mm(l) X 390mm(w) X 140mm(h) 17 7 Unit Double Ring Burner; Heavy-duty Cast Iron; Includes Pol Regulator And 1-metre Hose 16750 Btu Brass Valve With Individual Gas Control Minimal Assembly Required Weight; 3.9kg, Material;cast Iron, Dimensions: (lwh) 36cm X 20cm X 9cm, Fuel Type: Lpg Tank Cylinder With Content And Accessories 18 2 Pc Egg Ring, Stainless Steel, 8.5cm Diameter, 1.5cm Height 19 4 Box Face Masks; 3 Ply Non-woven Disposable Earloop Mask; Quantity: 50pcs/box 20 30 Pc Fish Drying Rack, 4-layer, 45x45x66cm, Foldable 21 6 Pc Fish Scaler, 20cm Stainless Steel 22 6 Pc Fish Scraping Tool, 20cm Stainless Steel 23 54 Unit Food Shelve, 2 Layers: Glass Thickness: 3/16 And 1/4, (w-14" X H-17" X L-30"); Adjustable Layer, Material: Glass & Aluminum With Sliding Door, Offer: Screen Sliding Door To Prevent Moisture 24 204 Pc Food Tray With Glass And Stainless Lid/cover, Stainless Body, Rubberized Stand 32x28x10cm 25 12 Pc Food Tray, Flat, Stainless, 60x40x2cm, Depth: 2cm 26 2 Unit Freezer Chest Type, Gross / Net Volume 10.6 Cu.ft. (10 Liters) / 10.1 Cu.ft. (286 Liters), Functionality 3-in-1 Function – Chilling | Freezing | Fast Freezing, Defrosting System: Manual Defrost, Evaporator:aluminum Defrost,led: 6 Led’s, P:2w, Lamp Life: Min. 50,000 Hours, Weight 40 Kg, Dimensions L 63 X W 111.4 X H 84.7 (cm), Key Features: Inverter Compressor, Sliding Glass Door, Embossed Door & Cabinet, Recessed Side Handle (left & Right), Led Light, Removable Gasket , 1x Basket Wire Shelf, 4x Roller Wheel 27 5 Pc Fruit Crate Plastic 21 X 15 X 12 Inches, Heavy Duty Plastic Material, Color : Black 28 37 Pc Frying Pan 14" In Diameter, Cast Iron 29 4 Unit Gas Range, Approx. 55-70cm (l) X 50-60cm (w) X 86-93cm (h); 4-gas Burner; 62l Gas Oven; Button Ignition; Top Glass Lid; Net Weight: Maximum Of 28kg; Pan Support: Light Cast Iron Pan Support 30 1 Box Gloves; 100pcs; Food Grade; Size: Medium(7.5cm); Thermoplastic Elastomer(tpe) Material 31 23 Pc Hairnet With Cap; White; Nylon; Washable 32 1 Unit Industrial Oven Stainless Steel, With Wall Insulator To Minimize Penetration Of Heat To The Walls, With Temperature Gauge, Approx. Outer Dimension: 46.5 X 23.5 X 30 Inches; Oven Stand/rack Is Made Of Metal With Rollers And Braking Systems; Stainless Steel Front Panel, With See Thru Glass; About 4 Inch Thickness Of Walls With 2 Trays Per Deck - 4 Trays Capacity; Gas Type 33 35 Pc Kawa 62 Cm Diameter 18 Cm Height, Aluminum With 2 Aluminum Handles 34 12 Pc Kitchen Apron, Waterproof; Stain Resistant Leather Apron 35 6 Pc Kitchen Scissors, Material: Stainless Steel And Plastic Silicone, Size: 22.5x7.3x1.2cm 36 3 Pc Long Handle Stainless Steel Soup Spoon; Color: Silver; Caliber Length; Approx. 12cm.14cm.16cm.18cm, Handle Length; Approx.45cm(17.72inches) 37 6 Pc Long Wooden Ladle; 14" Stainless Steel 38 58 Set Lpg Tank, 11kg Cylinder With Gas Regulator, 1.8m Hose & Steel Hose Clamp 39 9 Set Measuring Cup (set For Liquid), 1 Measuring Cup With Red Graphics; Made Of Nonporous Glass That Won't Warp, Stain, Or Absorb Odors; Glass Is Preheated Oven, Microwave, Fridge, Freezer & Dishwasher Safe; Dimension: Approx. 7.13" (l) X 6.75" (w) X 4.38" (h); Measuring Capacity: 500ml 40 9 Set Measuring Cups (set For Dry), Smithcraft Stainless Steel Measuring Cups Set Have 8 Cups.the Sizes Are: 1 Cup (240ml), 3/4 Cup (180ml), 2/3 Cup (160ml), 1/2 Cup (120ml), 1/3 Cup (80ml), 1/4 Cup (60ml), 1/8 Cup (30ml), 1/16 Cup (15ml),1 Locking Ring. 41 6 Unit Mini Electric Fan 7.5" - With Base 10'' 69hz 20w (for Bbq), Non-adjustable Height; Any Color; Electric Powered Fan; 3 Blade 42 21 Pc Mixing Bowl Medium, Approx. Diameter: 28cm, Height:11.2cm; Material: Stainless; Capacity: Atleast 4l 43 200 Pc Monoblock Chair Front:monoblock Chair, Front Legs Distance: 355mm Width Seat, With Backrest, Color: Beige, Seat Width :375 Mm, Deapth: 330 Mm, Side Legs Distance Left: 378 Mm, Side Legs Distance Right 378 Mm, Back Legs Distance: 210 Mm, Back Rest Height:779 Mm, Set Back Height: 405 Mm, Seat Height: 376 Mm, Gross Weight: 2.25 Kgs 44 54 Pc Monoblock Table, 36x36 Inches, H- 28 Inches, Color: Beige, Atleast 3mm Thick 45 2 Pc Non-slip Rectangular Chopping Board; Materials:polypropylene Plastic; Approx Length: 40cm; Width: 25cm; Thickness: 0.5cm; Color : White 46 45 Pc Palamigan Container W/ Gripo 15l, Dimension: 31.8x23.8x48.5cm, Material: High Quality Durable Plastic 47 1 Unit Pressure Cooker 50 Liters Capacity, Aluminum Alloy Material, Pressure: 90kpa, Dimension: 44cm Diameter X 47cm Height 48 40 Pc Round Glass Jars With Lid, 220ml 49 41 Pc Sandok, Stainless Steel, 24.7" Length, With Wooden Handle 50 33 Pc Sandok, Stainless Steel, Length: 14" 51 39 Pc Shansi, Stainless Steel, Length: 14" 52 9 Pc Stainless Steel Dough Cutter Scraper Baking Smoother Cake , Approx. Size: 14-15cm (l) X 11.5-12cm (w) And 22cm (h); Material: Stainless Steel 53 41 Pc Stainless Steel Food Tong 14" Length 54 5 Unit Steamer; Aluminum; About 16"/42cm Diameter; 3 Layers With Cover; With Handle Per Layer 55 3 Unit Vacuum Sealer Machine, 220v, 90w, Sealing Width: 270mm, Power Supply: Ac100-240v/50-60hz, Temperature Control Range: 170-210 Celsius, Abs Material, Size: 370*75*50 (mm) 56 15 Pack Vacuum Sealer Storage Pouches | Bpa Free, Commercial Grade For Food Storage & Sous Vides, Size: 17 X 25cm Material: Plastic, 100pcs/pack 57 27 Pc Water Jug/dispenser With Faucet, 5 Gallons, 20 Liters, Color: Blue, Durable And High Quality Plastic Material 58 7 Unit Weighing Scale; Analog; 20kg Capacity; Approx. Dimensions: 6-7" (l); 8-9" (w); 10-11" (h); Dual Unit (kg And Pounds) 59 2 Pc Wide Mouth Funnel, Stainless Steel, Top Opening: At Least 17 X 5.5 X 6cm, Bottom Opening: At Least 13 X 3.7 X 4cm 60 8 Pc Wire Whisk, Large, Stainless, Approx. 14-15" (l) Lot 3 - Fabrication Of Food Cart 1 7 Unit Bicycle With Sidecar: Bicycle Specifications: Bmx Type Bike (frame 1//2 Gi Hd, Rim Set Front X 10 G Wide Jap Hub, Rim Set Rear X 10g Wide Jap Hub, Tire 20 X 2.125 Jumbo, Tube 20 X 2.125, Handle Bar Painted Black, Fork Ex-900 Landing Gear Cp, Head Parts Nikyo/whw, H-post Bmx Ord.m, H-grip Ord. Opc Parts Neco Bearing Type, Opc Plate 36t, Chain Cp Bmx, Freewheel 24t, Pedal Opc Bearing Type, Seat Clamp/s-pin/ S-post P, Saddle With Spring, Footbreak With Spring "full Size" Frame, 175-180mm Cranks Side Car With Provision Of Umbrella And 2 Chest Coolers (52l Capacity) - Dimensions: ‎25.8" (l) X 16.2" (w) X 15.7" (h) Materials: 1/2 J1 Pipe 540, 316 X 1 Flat Square Bar, J1 Pipe De Una 520, 1/4 X 2 Flat Bar, 6203 Gi Set, Tire 20 X 2.125 Jumbo, Note: With Dole, Dilp Logo Fully Painted In A Galvanized Sheet Iron Attached On The Front Of The Sidecar With Approx. 15.7 Inches(h)x15.7 Inches(l) Fully Painted Color: Any Color 2 1 Unit Motorcycle Sidecar (for Fruits And Vegetable Vending): Metal Body, Dimensions L-4ft W-2ft H-2ft, With 17inch Side Wheel 3 11 Unit Negocart With Bicycle Roofing Materials: Bolt & Nut W/ Washer 3/16 X 1 Polycarbonate 6mm X 1.2 X 1.70 Welding Rod Body Materials:tubular 1 X 1 X 1.5;flat Bar 1/8 X 1;flat Bar 2' X 3/8 X 1;plain G.i.;sheet 4' X 8' #26;cylindrical Hinge 1/2" ᴓ;blind Rivets 1/8 X 1/2;cylindrical 1/2;cabinet Handle;cabinet Lock;round Bar 8mm ᴓ;transparents Barrier 1/4 X 4' X 8';welding Rod;stainless Sheet 4' X 8';plain Round Bar 16mm ᴓ: Bicycle Specs: Bmx Type Bike Frame, Front And Rear Free Wheel Hub For Rim Set Single Speed (wheel Set), Tire Size (20"x2.125 Jumbo), Interior Tube (20"x2.125), Bmx Handle Bar, Bmx Fork, Head Parts (h Post, Handle Grip), Chain (single Speed), Pedal (bearing Type), Seat Clamp, Saddle With Spring, Foot Brake (clamp W/ Spring), Crank Pedals (175mm-180mm Cranks) Note: With Dole, Dilp Logo And Tourism Spot At The Front And Side Of Cart, Logo Material: Weather Proof Sticker, Sizes Of Sticker: H-60cm X W-130cm (for Front Of Cart) And H-60cm X W:75cm (for Side Of Cart) Or H-23.6" X W-51" And H-23.6" X W-29.5" Fully Painted Color: Light Blue Lot 4 - Grooming Tools 1 1 Pc All Purpose Comb, 7inch, Plastic Material 2 3 Pc Barber Apron, With Two Pockets, Waterproof, Material: Fiber Size: Approximately 89x69cm - 35x27.2 Inches 3 1 Pc Barber Cape, 140cmx100cm Silk, Waterproof 4 1 Unit Barber Chair, Reclining, Modern Style, Chair Back Height: High-back; Upholstery: Faux Leather; Material: Stainless Steel; Dimension: 21"x22.5"x38" 5 1 Unit Clipper, Cordless, Includes 3 Metal Clip Attachment Comb Cutting Guides, 1/16", 1/8",3/16, 6.25 Inches And Weighs 13 Oz, Equipped With A 2191 Adjustable 0000 Blade 6 2 Unit Curling Iron, 38.5cm, Tourmaline Ceramic, 25-39w, 360 Degree Rotatable 7 2 Set Eyebrow Grooming Kit, 6pcs (2 Eyebrow Razor, 1 Facial Razor, 1 Brush, 1 Scissors, 1 Tweezer) 8 1 Pc Fade Brush, Material: Plastic & Nylon, (hxw) 12.3 X 2.3 Cm, Weight: 0.015 Kg 9 2 Unit Flat Iron, Ceramic Wide Plate, 100-240v Dual Votage, 40-59w, 27.8cm Long 10 2 Unit Hair Blower, 2 Speed - 3 Heat Settings, 2400w, Removable Filter Cover, Cool Shut Function, Dimension: 21.5x8.5x26.5cm 11 1 Set Hair Clips, Plastic, Size: Approximately 7.8cm 12 2 Set Hair Dying Tool Set, (5-pc) Small Brush - 19.5cmx4.5cm, Big Brush - 20.5x6cm, Secondary Comb - 19x5.5cm, Small Bowl - 13x4.5cm, 1 Pair Of Earmuffs 8x4.5cm 13 3 Pc Hair Shear, 6.9 Inch Stainless 14 10 Pc Hair Towel Turban, 49x18cm Microfiber 15 2 Set Make Up Brush Kit, 12 Pcs With Box 16 2 Set Make Up Kit, 35pcs (1 Eyeshadow, 1 Concealer, 4 Osmetic Brush, 3 Lipgloss, 1 Eyebrow Pencil, 1 Pressed Powder, 4 Lipstick, 4 Face Makeup, 1 Lip Balm, 1 12.5cmx19cm Makeup Bag, 1 Eyebrow Cream, 1 Primer, 1 Powder Puff, 1 Mascara) 17 2 Pc Makeup Kit Organizer, 50cmx39.5cmx21.5cm, Black,046 Glittery, Checkered 18 1 Pc Mirror, Double Sided Folding Mirror, (wxh) 24x 37cm, Weight: 0.532 Kg 19 1 Pc Neck Duster, Weight : 100g , Size : 18x7x7cm 20 1 Roll Neck Strips, (28cmx6.5cm) Self Adhesive, Material: Paper 21 4 Set Plastic Hair Roller, 25mm Assorted, 10-pc Large 22 3 Pc Pomade, 80g, Water-based 23 1 Pack Razor Blades, Durable, Stainless, 100 Pcs, (lxwxh) 14x10x1 24 1 Set Shaver, Abs Material,110-220v, Power: 3w, Size: 16.6x5.8cm, Battery Capacity: 600mah 25 2 Pc Shaving Gel, 195g With Aloe 26 2 Pc Talc Powder, 500g 27 1 Set Trimmer, Rechargable, 2 Blades, Power: 50-60 Hz, Voltage:100-240v, Dimension: 11.5x6.5x3cm 28 4 Pc Wide-tooth Comb, 16cm Plastic, Durable 29 1 Pc Wide-tooth Comb, Size: Approximately 21.5x5 Cm, Plastic Material Lot 5 - Sewing 1 7 Set Ball Point Pins, 250 Pcs Per Box With 8 Colors; Durable 2 8 Unit Bobbin Case, Diameter: 20.3mm Width: 11.7mm 3 8 Pc Bobbin, Diameter: 20.3mm Width: 11.7mm 4 4 Set Dressmaker's Shears, Material: Stainless Steel; Item Dimensions: Approximately 0.8" (l) X 3.9" (w) X 10" (h); Blade Length: 8"; Item Weight: Approximately 8.8 Ounces 5 1 Pc Edging/ Overlock Sewing Machine, Metal Material; Overlocker; 1 Stitch; Dimension(lxwxh) 12x13x14 6 3 Pc Electric High Speed Sewing Machine, Power: 90w; Rated Voltage: 220v; Gross Weight: About 7kg; Max Sewing Speed: 1,100 Stiches/min; Materials: Stainless Steel Needle Plate, Metal Frame; Dimensions: Approximately 44cm (l) X 16cm (w) X 28cm (h); Voltage: 220v, Secondary Lifting Height Or Presser Foot: 14mm; Needle Pitch: From 0-4.5mm, Needle Width: From 0-7.0mm 7 4 Pc Flat Iron, 1200w; Stainless Steel Sole Plate; Power Light Indicator; With Steaming/spray Function 8 4 Set French Curve, Dimension(21.65x0.39x7.09); 4.6 Ounce; Made Of Aluminum Or Plastic 9 4 Pc L-square, Material: Stainless; Item Weight: 0.32oz; Product Dimensions: Approx. 14" (l) X 24" (w) 10 1 Pc Manual Sewing Machine With Motor And Foot Controller, Metal Material, Heavy Duty, 9kg Weight, 1 Stitch Dimensions, (lxwxh) 12x13x14 11 4 Unit Meter Stick, Yellow Color; Wood Type 12 4 Pc Needle Threader, Metal Material; Oval Shape; 1 Inch Size 13 31 Pack Sewing Machine Needle, Flat Needles 10pcs/pack 14 11 Pc Sewing Threads 12pcs/box, Material: Cotton; Package Dimensions: Approx. 5.71" (l) X 3.74" (w) X 2.36" (h); Thread Size: Approx. 56mm (h) X 22mm (w); 550 Yards Each Roll 15 25 Pc Tailor’s Chalk, Square Shape; Orange Color;fades Or Brushes Away Easily 16 4 Pc Tape Measure, Material: Durable Soft Plastic; Color: Blue; Measurements: Inches (can Measure Upto 60") And Centimetres (can Measure Upto 150cm) Xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 2. Delivery Of The Goods Is Required Ninety (90) Calendar Days Delivery Period And Upon Receipt Of Notice To Proceed And Purchase. Bidders Should Have Completed, Within Two (2) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii. Instructions To Bidders. 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) 9184, Otherwise Known As The “government Procurement Reform Act”. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra 5183. 4. Interested Bidders May Obtain Further Information From Local Government Unit Of Mercedes, Camarines Norte-bac Secretariat And Inspect The Bidding Documents At The Address Given Below During Office Hours - 8:00 Am-12:00 To 1:00 Pm-5:00 Pm. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On December 14, 2024 Until 8:30 Am Of January 6, 2025 From The Address Below And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of Five Thousand Pesos Only Php5,000.00. 6. The Local Government Unit Of Mercedes, Camarines Norte Will Hold A Pre-bid Conference On December 23, 2024 9:00am At Bids And Awards Committee Office- Second Floor Jpl Sports Complex - Municipal Compound, Eco Avenue Street, Barangay 5, Mercedes, Camarines Norte Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through (i) Manual Submission At The Office Address Indicated Below, On Or Before 8:30am January 6, 2025. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On 9:00 Am Of January 6, 2025 At The Bids And Awards Committee Office- Second Floor Jpl Sports Complex - Municipal Compound, Eco Avenue Street, Barangay 5, Mercedes, Camarines Norte. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend At The Address Below. 10. The Local Government Unit Of Mercedes, Camarines Norte, Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Section 41 Of Ra 9184 And Its Irr, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: Macario B. Totanes Municipal Planning And Development Office Lgu Mercedes Municipal Compound, Barangay 5, Mercedes, Camarines Norte 0998-576-8321 Arsenia M. Ordiales Bac Secretariat Bids And Awards Committee Office 2nd Floor Jpl Sports Complex, Lgu Mercedes Municipal Compound, Barangay 5, Mercedes, Camarines Norte 0908-896-9684 Email Address: Lgubac.mercedes@yahoo.com 12. You May Visit The Website: For Downloading Of Bidding Documents: Www.mercedes.gov.ph December 13, 2024 ________________________________ Macario B. Totanes Bac Chairman

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

Healthcare and Medicine
United States
Closing Date3 Jan 2025
Tender AmountRefer Documents 
Description: Sources Sought Notice important: Read This Notice In Its Entirety Before Responding. Services Are Sporadic And No Routine Schedule Or Quantity Can Be Firmly Identified the Department Of Veterans Affairs (va), Network Contracting Office (nco) 23, On Behalf Of The Sioux Falls Sd Va Hospital, Is Seeking Information And Potential Sources For Onsite Licensed General Surgeon Gastroenterology Services. The Period Of Performance Will Be For One Year And Includes Four (4) One-year Option Periods. the Contractor Shall Provide Onsite Licensed General Surgeon Gastroenterology Services In Accordance With The Terms, Conditions, And Specifications Contained Herein To Beneficiaries Of The Department Of Veteran Affairs (va), Sioux Falls Va Health Care System (vahcs). The Total Number Of Hours Required Is 416 Hours Annually. Services May Be Required On A 24-hour Per Day, Seven Days Per Week Basis, Including Holidays And Weekends. On Call Services May Be Required. See Attached Performance Work Statement (pws) For Additional Information. the Naics For This Requirement Is 561320 Temporary Help Services, Which Has A Small Business Size Standard Of $34.0 Million. It Is The Intent Of The Va To Issue A Single Award, Firm Fixed Price Contract. this Is A Sources Sought Notice Only. This Sources Sought Notice Will Be Used To Obtain Information Regarding The Provision Of F Onsite Licensed General Surgeon Gastroenterology Services From Potential Vendors, Identify Potential Vendors That Would Be Interested And Capable Of Providing Onsite Licensed General Surgeon Gastroenterology Services Within The Requested Timeframe, And To Assist The Contracting Officer In Making A Set-aside Determination. This Source Sought Notice And Any Responses Are For Market Research Purposes Only And Shall Not Be Considered An Obligation On The Part Of The Government To Acquire Any Services. this Source Sought Notice Is Not A Solicitation, And No Contractual Arrangement Will Be Made As A Result. Vendors Are Advised That No Entitlement To Payment Of Direct Or Indirect Costs Or Charges By The Government Will Arise Because Of A Contractor Submission To This Sources Sought Notice Or The Government's Use Of Such Information. All Costs Associated With Responding To This Sources Sought Notice Are Solely At The Responding Vendors Expense. The Government Reserves The Right To Reject, In Whole Or In Part, Any Vendor's Input Resulting From This Sources Sought Notice. Information Submitted In Response To This Sources Sought Notice Will Not Be Returned. all Submitted Information Should Be Unclassified Or Non-proprietary. Vendors Are Solely Responsible For Properly Marking And Clearly Identifying Any Proprietary Information Or Trade Secrets Contained With Its Response. The Government Will Not Be Liable For Or Suffer Any Consequential Damages For Any Proprietary Information Not Properly Marked And Clearly Identified. by Responding To This Sources Sought Notice, The Vendor Provides The Government Permission To Share Its Submitted Capabilities And Contact Information With Other Government Organizations In Relationship To Similar Requirements For Market Research Purposes. To Be Considered Complete, Responses To This Sources Sought Notice Shall Include The Information Below. provide A Brief Description Of The Company Background, Experience In Providing Onsite Licensed General Surgeon Gastroenterology Services As The Prime Contractor/subcontractor, Socioeconomic Status, Past Performance With Government Contracts, And Contractor Sam Uei Number. indicate If Subcontractors/partners Be Used For Any Part Of The Delivery Of Onsite Licensed General Surgeon Gastroenterology Services? If Yes, Specify The Duties Of The Prime Contractor And Any Subcontractors/partners. if Company Is A Veteran And/or Small Business, Indicate If Able To Comply With The Limitations On Subcontracting At 13 Cfr 125.6, Which States That For Services A Small Business Concern Must Agree That It Will Not Pay More Than 50% Of The Amount Paid By The Government To It To Firms That Are Not Similarly Situated. include Copy Of Small Business Administration Verification At Veteran Small Business Certification (sba.gov) If Claiming Veteran-owned Small Business Or Service-disabled Veteran-owned Small Business Socioeconomic Status As Prime Contractor Or For Any Subcontractors/partners. provide A Copy Of Current Certificate Of Liability Insurance In Vendor S Name. all Interested Parties, Regardless Of Socioeconomic Status, Capable Of Providing The Required Onsite Licensed General Surgeon Gastroenterology Services Above Shall Submit A Response Via Email To The Contracting Specialist At Tina.bernad@va.gov No Later Than January 3, 2025, 11:00 A.m. Central Time. performance Work Statement onsite General Surgeon Gastroenterology Services general: services Provided: The Contractor Shall Provide Board Certified/board Eligible General Surgery Physician Services Onsite In Accordance With The Specifications Contained Herein To Beneficiaries Of The Va And The Royal C. Johnson Veterans Memorial Hospital (sioux Falls Va). place Of Performance: Contractor Shall Furnish Services At The Royal C. Johnson Veterans Memorial Hospital (sioux Falls Va), 2501 W 22nd St, Sioux Falls, Sd 57105. authority: Title 38 Usc 8153, Health Care Resources (hcr) Sharing Authority. Remember To Identify The Federal Acquisition Regulation (far) Parts Used (far 12 In Combination With 13, 15 And/or Va Acquisition Regulation (vaar) Part 873) policy/directives/handbooks. The Contractor Shall Be Subject To The Following Policies, Including Any Subsequent Updates During The Period Of Performance. The Policies Listed Below Can Be Accessed Electronically At The Following: Va Publications Vha Publications va Directive 1663: Health Care Resources (hcr) Contracting Buying Title 38 U.s.c. 8153 1.4.2. Vha Directive 1003.04: Vha Patient Advocacy vha Directive 1065: Productivity And Staffing Guidance For Specialty Provider Group Practice vha Directive 1088(1): Communicating Test Results To Providers And Patients vha Directive 1100.18: Reporting And Responding To State Licensing Boards vha Directive 1100.20: Credentialing Of Health Care Providers vha Directive 1100.21: Privileging vha Directive 1192.01: Seasonal Influenza Vaccination Program For Vha Health Care Personnel vha Directive 1220(1): Facility Procedure Complexity Designation Requirements To Perform Invasive Procedures In Any Clinical Setting vha Directive 1400.01: (not Applicable, Please Remove) vha Directive 1605.01: Privacy And Release Of Information vha Directive 1907.01: Vha Health Information Management And Health Records vha Handbook 1100.17: National Practitioner Data Bank (npdb) Reports vha Handbook 1400.04: (not Applicable, Please Remove) privacy Act Of 1974 (5 U.s.c. 552a) As Amended: Http://www.justice.gov/oip/foia_updates/vol_xvii_4/page2.htm acronyms/definitions: Terms Used In This Contract Shall Be Interpreted As Follows Unless The Context Expressly Requires A Different Construction And/or Interpretation. In Case Of A Conflict In Language Between The Definitions And Other Sections Of This Contract, The Language In This Section Shall Govern. abs: American Board Of Surgery Http://www.absurgery.org/ acgme: Accreditation Council For Graduate Medical Education acls: Advanced Cardiac Life Support ajic: American Journal For Infection Control aql: Acceptable Quality Level baa: Business Associate Agreement bba: Balanced Budget Act bls: Basic Life Support cdc: Centers For Disease Control And Prevention cdr: Contract Deficiency Report ceu: Certified Education Unit clinical Privileging: Clinical Privileging Is The Process By Which A Practitioner, Licensed For Independent Practice; E.g., Without Supervision, Direction, Required Sponsor, Preceptor, Mandatory Collaboration, Etc.; Is Permitted By Law And The Facility To Practice Independently, To Provide Specific Medical Or Other Patient Care Services Within The Scope Of The Individual S License, Based Upon The Individual S Clinical Competence As Determined By Peer References, Professional Experience, Health Status, Education, Training And Licensure. Clinical Privileges Must Be Facility-specific And Provider-specific, And Within Available Resources. cme: Continuing Medical Education cmp: Civil Monetary Penalty cms: Centers For Medicare And Medicaid Services co: Contracting Officer: The Person Executing This Contract On Behalf Of The Government With The Authority To Enter Into And Administer Contracts And Make Related Determinations And Findings. coi: Conflict Of Interest cor: Contracting Officer S Representative: A Person Appointed By The Co To Take Necessary Action To Ensure The Contractor Performs In Accordance With And Adheres To The Specifications Contained In The Contract And To Protect The Interest Of The Government. The Cor Shall Report To The Co Promptly Any Indication Of Non-compliance In Order That Appropriate Action Can Be Taken. cos: Chief Of Staff cpars: Contractor Performance Assessment Reporting System credentialing: Credentialing Is The Process Of Obtaining, Verifying, And Assessing The Qualifications Of A Health Care Provider To Provide Care Or Services In Or For The Va Health Care System. Credentials Are Documented Evidence Of Licensure, Education, Training, Experience Or Other Qualifications. dea: Drug Enforcement Agency ehr: Electronic Health Record - Electronic Health Record System Used By The Va epa: Environmental Protection Agency fapiis: Federal Awardee Performance And Integrity Information System far: Federal Acquisition Regulation foia: Freedom Of Information Act fppe: Focused Provider Practice Evaluation fsmb: Federation Of State Medical Boards fte: Full Time Equivalent: Va S Standard Definition Is For Full Time Working The Equivalent Of 80 Hours Every Two Weeks, 2080 Hours Per Year.  however, Providers May Propose Using Their Standard Fte Definition. hhs: Department Of Health And Human Services hicpac: Hospital Infection Practices Advisory Committee hipaa: Health Insurance Portability And Accountability Act igra: Interferon-gamma Release Assays iso: Information Security Officer key Personnel: The Individuals Specified In This Contract Who Are Essential To Work Performance. mri: Magnetic Resonance Imaging mst: Military Sexual Trauma npi: National Provider Identifier. Npi Is A Standard, Unique 10-digit Numeric Identifier Required By Hipaa. The Vha Must Use Npis In All Hipaa-standard Electronic Transactions For Individual (health Care Practitioners) And Organizational Entities (medical Centers). nppes: National Plan And Provider Enumeration System nso: National Surgery Office ogc: Office Of General Counsel oig: Office Of Inspector General oppe: Ongoing Provider Practice Evaluation or: Operating Room pop: Period Of Performance ppd: Purified Protein Derivative ppirs: Past Performance Information Retrieval System pws: Performance Work Statement qa/qi: Quality Assurance/quality Improvement qm/pi: Quality Management/performance Improvement qasp: Quality Assurance Surveillance Plan rfp: Request For Proposal scs: Specialty Care Services ssac: Sole Source Affiliate Contract tjc: The Joint Commission tst: Tuberculosis Skin Test usc: United States Code va: Department Of Veterans Affairs va-fsc: Va Financial Services Center vaar: Va Acquisition Regulation vetpro: Is Vha S Mandatory Credentialing Software Platform To Document The Credentialing Of Vha Health Care Providers. This System Facilitates Completion Of A Uniform, Accurate And Complete Credentials File. vha: Veterans Health Administration vista: Veterans Integrated Systems Technology Architecture qualifications: staff/facility license: The Contractor S Physician(s) Assigned By The Contractor To Perform The Services Covered By This Contract Shall Have A Current License To Practice Medicine In Any State, Territory, Or Commonwealth Of The United States Or The District Of Columbia) When Services Are Performed Onsite On Va Property. all Licenses Held By The Key Personnel Working On This Contract Shall Be Full And Unrestricted Licenses. Contractor S Physician(s) Who Have Current, Full And Unrestricted Licenses In One Or More States, But Who Have, Or Ever Had, A License Restricted, Suspended, Revoked, Voluntarily Revoked, Voluntarily Surrendered Pending Action Or Denied Upon Application Will Not Be Considered For The Purposes Of This Contract. board Certification: All Contractor S Physician(s) Shall Be Board Certified/board Eligible By The Abs Http://www.absurgery.org/, And Be Currently Certified In Bls, Acls Or Equivalency. All Continuing Education Courses Required For Maintaining Certification Must Be Kept Up To Date At All Times. Documentation Verifying Current Certification Shall Be Provided By The Contractor To The Va Cor On An Annual Basis For Each Year Of Contract Performance. credentialing And Privileging: Credentialing And Privileging Is To Be Done In Accordance With The Provisions Of Vha Directive 1100.20 And Vha Directive 1100.21 Referenced Above. The Contractor Is Responsible To Ensure That Proposed Physician(s) Possesses The Requisite Credentials Enabling The Granting Of Privileges. No Services Shall Be Provided By Any Contractor S Physician(s) Prior To Obtaining Approval By The Facility Medical Executive Board And Medical Center Director. if A Contractor S Physician(s) And/or Other Contract Provider(s) Are Not Credentialed And Privileged Or Has Credentials/privileges Suspended Or Revoked, The Contractor Shall Furnish An Acceptable Substitute Without Any Additional Cost To The Government. technical Proficiency: Contractor S Physician(s) Shall Be Technically Proficient In The Skills Necessary To Fulfill The Government S Requirements, Including The Ability To Speak, Understand, Read And Write English Fluently. Contractor Shall Provide Documents Upon Request Of The Co/cor To Verify Current And Ongoing Competency, Skills, Certification And/or Licensure Related To The Provision Of Care, Treatment And/or Services Performed. Contractor Shall Provide Verifiable Evidence Of All Educational And Training Experiences Including Any Gaps In Educational History For All Contractor S Physician(s) And Contractor S Physician(s) Shall Be Responsible For Abiding By The Facility's Medical Staff By-laws, Rules, And Regulations (referenced Herein) That Govern Medical Staff Behavior. continuing Medical Education (cme)/ Certified Education Unit (ceu) Requirements: Contractor Shall Provide The Cor Copies Of Current Cmes As Required Or Requested By The Facility. Contractor S Physician(s) Registered Or Certified By National/medical Associations Shall Continue To Meet The Minimum Standards For Cme To Remain Current. Contractor Shall Report Cme Hours To The Credentials Office For Tracking. These Documents Are Required For Both Privileging And Re-privileging. Failure To Provide Shall Result In Loss Of Privileges For Contractor S Physician(s). training (acls, Bls, Ehr And Va Mandatory): Contractor Shall Meet All Va Educational Requirements And Mandatory Course Requirements Defined Herein; All Training Must Be Completed By The Contractor S Physician(s) As Required By The Va. Other Training May Become Required. Va Will Communicate Any Changes To The Training Requirement To The Contractor. training frequency annual Hours acls/bls as Necessary To Maintain Certification. active Threat Training annually 30 Minutes blood Administration: Complication annually 30 Minutes ehr annually 2 Hours government Ethics annually 30 Minutes hospice And Palliative Care For Va Clinicians annually 30 Minutes military Sexual Trauma (mst) For Medical Providers annually 30 Minutes moderate Sedation In-service Training annually 30 Minutes pact Act 2022 Toxic Exposure Screening (tes) annually 30 Minutes patient Abuse annually 30 Minutes patient Rights annually 30 Minutes patient Safety annually 30 Minutes prevention/management Of Disruptive Behavior/violence Prevention Level I annually 30 Minutes prevention Of Workplace Harassment/no Fear Act annually 30 Minutes suicide Prevention: Suicide Risk Management Training For Clinicians annually 30 Minutes sux Infection Control And Blood Borne Pathogens annually 30 Minutes va Core Values Training (icare Recommitment) annually 30 Minutes va Privacy And Information Security Awareness And Rules Of Behavior annually 30 Minutes vha Mri Safety Training Level 1 Training (all Who Enter Mri Suites) annually 30 Minutes vha Privacy And Hipaa Focused Training annually 30 Minutes vista Imaging one Time 30 Minutes radiation Safety annually 30 Minutes standard Infection Control Measures (ppd, Immunizations, Etc.): Contractor Shall Provide Proof Of The Following For Physicians Within Five (5) Calendar Days After Contract Award And Prior To The First Duty Shift To The Cor And Co. Tests Shall Be Current Within The Past Year. tuberculosis Testing: Contractor Shall Provide Proof Of A Negative Tuberculosis Skin Test (tst) Or Interferon-gamma Release Assays (igra) For All Contractor S Physician(s) Upon Hire In Accordance With Cdc Guidance. (this Is Applicable To All Health Care Workers). A Negative Chest Radiographic Report For Active Tuberculosis Shall Be Provided In Cases Of Positive Tst Or Igra Results. measles, Mumps, & Rubella Testing: Contractors Shall Provide Proof Of Immunity For All Contractor Physicians {this Is Applicable To All Health Care Workers}. varicella: Contractors Shall Provide Proof Of Immunity For All Contractor Physicians {this Is Applicable To All Health Care Workers}. acellular Pertussis: Contractors Shall Provide Proof Of 1 Dose Of Tdap Vaccination For All Contractor Physicians {this Is Applicable To All Health Care Workers}. influenza: Contractors Shall Provide Proof That All Contractor Physicians Have Received The Annual Influenza Vaccine Unless It Is Contraindicated. If The Contractor Physician Has A Medical Contraindication To The Vaccine They Shall Be Required To Wear A Mask During The Influenza Season. {this Is Applicable To All Health Care Workers}. covid-19: Contractors Shall Comply With Vha Supplemental Contract Requirements For Combatting Covid-19 {this Is Applicable To All Health Care Workers}. See Section D Attachment. osha Regulation Concerning Occupational Exposure To Bloodborne Pathogens: Contractor Shall Provide Evidence Of Completing And Passing Generic Self-study Blood-borne Pathogen Training For All Contractor S Physician(s) {this Is Applicable To All Health Care Workers}; Provide Their Own Hepatitis B Vaccination Series And Hepatitisâ b Surface Antigen Test Resultsâ following The Hepatitis B Vaccination Series; Maintain An Exposure Determination And Control Plan; Maintain Required Records; And Ensure That Proper Follow-up Evaluation Is Provided Following An Exposure Incident. the Facility Shall Notify The Contractor Of Any Significant Communicable Disease Exposures As Appropriate. Contractor Shall Adhere To Current Cdc/hicpac Guideline For Infection Control In Health Care Personnel (as Published In American Journal For Infection Control - Ajic 1998; 26:289-354 Http://www.cdc.gov/hicpac/pdf/infectcontrol98.pdf) For Disease Control. Contractor Shall Provide Follow Up Documentation Of Clearance To Return To The Workplace Prior To Their Return. npi: Npi Is A Standard, Unique 10-digit Numeric Identifier Required By Hipaa. The Vha Must Use Npis In All Hipaa-standard Electronic Transactions For Individual (health Care Practitioners) And Organizational Entities (medical Centers). The Contractor Shall Have Or Obtain Appropriate Npi And If Pertinent The Taxonomy Code Confirmation Notice Issued By The Cms Nppes Be Provided To The Co With The Proposal. dea: Contractor Shall Provide Copy Of Current Dea Certificate. Conflict Of Interest (coi): The Contractor And All Contractor S Physician(s) Are Responsible For Identifying And Communicating To The Co And Cor Conflicts Of Interest At The Time Of Proposal And During The Entirety Of Contract Performance. At The Time Of Proposal, The Contractor Shall Provide A Statement Which Describes, In A Concise Manner, All Relevant Facts Concerning Any Past, Present, Or Currently Planned Interest (financial, Contractual, Organizational, Or Otherwise) Or Actual Or Potential Organizational Conflicts Of Interest Relating To The Services To Be Provided. The Contractor Shall Also Provide Statements Containing The Same Information For Any Identified Consultants Or Subcontractors Who Shall Provide Services. The Contractor Must Also Provide Relevant Facts That Show How It S Organizational And/or Management System Or Other Actions Would Avoid Or Mitigate Any Actual Or Potential Organizational Conflicts Of Interest. These Statements Shall Be In Response To The Vaar Provision 852.209-70 Organizational Conflicts Of Interest And Fully Outlined In Response To The Subject Attachment In Section D Of The Solicitation Document. citizenship Related Requirements: the Contractor Certifies That The Contractor Shall Comply With Any And All Legal Provisions Contained In The Immigration And Nationality Act Of 1952, As Amended; Its Related Laws And Regulations That Are Enforced By Homeland Security, Immigration And Customs Enforcement And The U.s Department Of Labor As These May Relate To Non-immigrant Foreign Nationals Working Under Contract Or Subcontract For The Contractor While Providing Services To Va Patient Referrals. while Performing Services For The Va, The Contractor Shall Not Knowingly Employ, Contract Or Subcontract With An Illegal Alien; Foreign National Non-immigrant Who Is In Violation Their Status, As A Result Of Their Failure To Maintain Or Comply With The Terms And Conditions Of Their Admission Into The United States. Additionally, The Contractor Is Required To Comply With All E-verify Requirements Consistent With Executive Order 12989 And Any Related Pertinent Amendments, As Well As Applicable Far. if The Contractor Fails To Comply With Any Requirements Outlined In The Preceding Paragraphs Or Its Agency Regulations, The Va May, At Its Discretion, Require That The Foreign National Who Failed To Maintain Their Legal Status In The United States Or Otherwise Failed To Comply With The Requirements Of The Laws Administered By Homeland Security, Immigration And Customs Enforcement And The U.s Department Of Labor, Shall Be Prohibited From Working At The Contractor S Place Of Business That Services Va Patient Referrals; Or Other Place Where The Contractor Provides Services To Veterans Who Have Been Referred By The Va; And Shall Form The Basis For Termination Of This Contract For Breach. this Certification Concerns A Matter Within The Jurisdiction Of An Agency Of The United States And The Making Of A False, Fictitious, Or Fraudulent Certification May Render The Maker Subject To Prosecution Under 18 U.s.c. 1001. the Contractor Agrees To Obtain A Similar Certification From Its Subcontractors. The Certification Shall Be Made As Part Of The Offerors Response To The Rfp Using The Subject Attachment In Section D Of The Solicitation Document. annual Oig Statement: In Accordance With Hipaa And The Balanced Budget Act (bba) Of 1977, The Hhs Oig Has Established A List Of Parties And Entities Excluded From Federal Health Care Programs. Specifically, The Listed Parties And Entities May Not Receive Federal Health Care Program Payments Due To Fraud And/or Abuse Of The Medicare And Medicaid Programs. therefore, Contractor Shall Review The Hhs Oig List Of Excluded Individuals/entities On The Hhs Oig Web Site At Http://oig.hhs.gov/exclusions/index.asp To Ensure That The Proposed Contractor S Physician(s) Are Not Listed. Contractor Should Note That Any Excluded Individual Or Entity That Submits A Claim For Reimbursement To A Federal Health Care Program, Or Causes Such A Claim To Be Submitted, May Be Subject To A Civil Monetary Penalty (cmp) For Each Item Or Service Furnished During A Period That The Person Was Excluded And May Also Be Subject To Treble Damages For The Amount Claimed For Each Item Or Service. Cmp S May Also Be Imposed Against The Contractor That Employ Or Enter Into Contracts With Excluded Individuals To Provide Items Or Services To Federal Program Beneficiaries. by Submitting Their Proposal, The Contractor Certifies That The Hhs Oig List Of Excluded Individuals/entities Has Been Reviewed And That The Contractors Are And/or Firm Is Not Listed As Of The Date The Offer/bid Was Signed. clinical/professional Performance: The Qualifications Of Contractor Personnel Are Subject To Review By Facility Cos Or His/her Clinical Designee And Approval By The Medical Center Director As Provided In Vha Directive 1100.20 And Vha Directive 1100.21. Clinical/professional Performance Monitoring And Review Of All Clinical Personnel Covered By This Contract For Quality Purposes Will Be Provided By The Facility Cos And/or The Chief Of The Service Or His Designee. A Clinical Cor May Be Appointed, However, Only The Co Is Authorized To Consider Any Contract Modification Request And/or Make Changes To The Contract During The Administration Of The Resultant Contract. non Personal Healthcare Services: The Parties Agree That The Contractor And All Contractor S Physician(s) Shall Not Be Considered Va Employees For Any Purpose. indemnification: The Contractor Shall Be Liable For, And Shall Indemnify And Hold Harmless The Government Against, All Actions Or Claims For Loss Of Or Damage To Property Or The Injury Or Death Of Persons, Arising Out Of Or Resulting From The Fault, Negligence, Or Act Or Omission Of The Contractor, Its Agents, Or Employees. prohibition Against Self-referral: Contractor S Physicians Are Prohibited From Referring Va Patients To Contractor S Or Their Own Practice(s). inherent Government Functions: Contractor And Contractor S Physician(s) Shall Not Perform Inherently Governmental Functions. This Includes, But Is Not Limited To, Determination Of Agency Policy, Determination Of Federal Program Priorities For Budget Requests, Direction And Control Of Government Employees (outside A Clinical Context), Selection Or Non-selection Of Individuals For Federal Government Employment Including The Interviewing Of Individuals For Employment, Approval Of Position Descriptions And Performance Standards For Federal Employees, Approving Any Contractual Documents, Approval Of Federal Licensing Actions And Inspections, And/or Determination Of Budget Policy, Guidance, And Strategy. employee Status: The Contractor Shall Be Responsible For Protecting Contractor S Physician(s) Furnishing Services. To Carry Out This Responsibility, The Contractor Shall Provide Or Certify That The Following Is Provided For All Their Staff Providing Services Under The Resultant Contract: workers Compensation professional Liability Insurance health Examinations income Tax Withholding, And social Security Payments. tort Liability: The Federal Tort Claims Act Does Not Cover Contractor Or Contractor S Physician(s). When A Contractor Or Contractor S Physician(s) Has Been Identified As A Provider In A Tort Claim, The Contractor Shall Be Responsible For Notifying Their Legal Counsel And/or Insurance Carrier. Any Settlement Or Judgment Arising From A Contractor S (or Contractor S Physician(s)) Action Or Non-action Shall Be The Responsibility Of The Contractor And/or Insurance Carrier. key Personnel: the Va Full Time Equivalent (fte) For The Services Required Is 416 Hours = .20 Va Fte. the Minimum Number Of Board Certified/board Eligible General Surgery Physicians Required To Be Onsite Daily Is 1 To Be Onsite As Defined In Paragraph Hours Of Operation In This Section. the Contractor Shall Be Responsible For Providing Coverage To The Va During Periods Of Vacancies Of The Contractor S Personnel Due To Sick Leave, Personal Leave, Vacations And Additional Coverage As Required. In The Event A Scheduled Physician Is Unable To Complete An Assigned Shift, The Contractor Shall Provide Replacement Physician Coverage Within 2 Hours And Notify The Cor Immediately Of The Schedule Change. personnel Substitutions: During The First Ninety (90) Calendar Days Of Performance, The Contractor Shall Make No Substitutions Of Key Personnel Unless The Substitution Is Necessitated By Illness, Death Or Termination Of Employment. The Contractor Shall Notify The Co, In Writing, Within 7 Calendar Day(s) After The Occurrence Of Any Of These Events And Provide The Information Required Below. After 90 Days, The Contractor Shall Submit The Information Required Below To The Co At Least 60 Calendar Days Prior To Making Any Permanent Substitutions. the Contractor Shall Provide A Detailed Explanation Of The Circumstances Necessitating The Proposed Substitutions, Complete Resumes For The Proposed Substitutes, And Any Additional Information Requested By The Co. Proposed Substitutes Shall Have Comparable Qualifications To Those Of The Persons Being Replaced. The Co Will Notify The Contractor Within 7 Calendar Days After Receipt Of All Required Information Of The Decision On The Proposed Substitutes. The Contract Will Be Modified To Reflect Any Approved Changes Of Key Personnel. for Temporary Substitutions Where The Key Person Shall Not Be Reporting To Work For 2 Consecutive Workdays Or More, The Contractor Shall Provide A Qualified Replacement For The Key Person. The Substitute Shall Have Comparable Qualifications To The Key Person. Any Period Exceeding Two Weeks Will Require The Procedure As Stated Above. the Government Reserves The Right To Refuse Acceptance Of Any Contractor Personnel At Any Time After Performance Begins, If Personal Or Professional Conduct Jeopardizes Patient Care Or Interferes With The Regular And Ordinary Operation Of The Facility. Breaches Of Conduct Include Intoxication Or Debilitation Resulting From Drug Use, Theft, Patient Abuse, Dereliction Or Negligence In Performing Directed Tasks, Or Other Conduct Resulting In Formal Complaints By Patient Or Other Staff Members To Designated Government Representatives. Standards For Conduct Shall Mirror Those Prescribed By Current Federal Personnel Regulations. Should The Va Cos Or Designee Show Documented Clinical Problems Or Continual Unprofessional Behavior/actions With Any Contractor S Physician(s), S/he May Request, Without Cause, Immediate Replacement Of Said Contractor S Physician(s). The Co And Cor Shall Deal With Issues Raised Concerning Contractor S Physician(s) Conduct. The Final Arbiter On Questions Of Acceptability Is The Co. contingency Plan: Because Continuity Of Care Is An Essential Part Of Facility S Medical Services, The Contractor Shall Have A Contingency Plan In Place To Be Utilized If The Contractor S Physician(s) Leaves Contractor S Employment Or Is Unable To Continue Performance In Accordance With The Terms And Conditions Of The Resulting Contract. va Hours Of Operation/scheduling: va Business Hours: Va Clinc Days And Prouders Are From Monday Through Friday 7am To 3pm. clinic Or Or Schedule: Contract S Physician(s) Will Be Scheduled Tuesday S And Friday S Between The Hours Of 7am To 3pm. patients Must Be Seen By A Contractor S Physician(s) Onsite At The Sfvamc In A Timely Manner In Accordance With Va Rules And Regulations On Clinic Wait Times And Consult Completion. Contractor Shall Notify The Cor At Least Monthly About Any Obstacles To Meeting This Performance Measure. contractor S Physician(s) Shall Be Available And Present In Clinic During Normal Sfvamc Clinic Hours, Which Will Be Established, And May Be Revised, As Deemed Appropriate For Patient Care By The Cos. Currently, Normal Clinic Hours Are 7am To 3pm. federal Holidays: The Following Holidays Are Observed By The Va: new Year S Day president S Day martin Luther King S Birthday memorial Day juneteenth independence Day labor Day columbus Day veterans Day thanksgiving christmas any Day Specifically Declared To Be A National Holiday. cancellations: 45 Days Notice From Contractor, If No Provider S Are Available. contractor Responsibilities: clinical Personnel Required: The Contractor Shall Provide Contractor S Physician(s) Who Are Competent, Qualified Per This Performance Work Statement And Adequately Trained To Perform Assigned Duties. contractor S Physician(s) Shall Be Responsible For Signing In And Out When In Attendance. Time Sheets Will Be Used By The Cor To Confirm Hours/day And Services Provided Against The Contractor S Invoices. standards Of Care: The Contractor S Physician(s) Care Shall Cover The Range Of General Surgery Services As Would Be Provided In A State-of-the-art Civilian Medical Treatment Facility And The Standard Of Care Shall Be Of A Quality, Meeting Or Exceeding Currently Recognized The Joint Commission (tjc), Va And National Standards As Established By: the Abs Http://www.absurgery.org/ the Professional Standards Of Tjc: Http://www.jointcommission.org/standards_information/standards.aspx the Standards Of The American Hospital Association (aha): Http://www.hpoe.org/resources?show=100&type=8 the Requirements Contained In This Pws (not Applicable) medical Records: authorities: Contractor S Physician(s) Providing Healthcare Services To Va Patients Shall Be Considered As Part Of The Department Healthcare Activity And Shall Comply With The 5 U.s.c.552a (privacy Act), 38 U.s.c. 5701 (confidentiality Of Claimants Records), 5 U.s.c. 552 (foia), 38 U.s.c. 5705 (confidentiality Of Medical Quality Assurance Records) 38 U.s.c. 7332 (confidentiality Of Certain Medical Records), Title 5 U.s.c. § 522a (records Maintained On Individuals) As Well As 45 C.f.r. Parts 160, 162, And 164 (hipaa). hipaa: This Contract And Its Requirements Meet Exception In 45 Cfr 164.502(e), And Do Not Require A Baa In Order For Covered Entity To Disclose Protected Health Information To: A Health Care Provider For Treatment Of Va Patients. Based On This Exception, A Baa Is Not Required For This Contract. Health Records Generated By This Contract Or Provided To The Contractors By The Va Are Covered By The Va Privacy Act System Of Records Entitled Patient Medical Records-va (24va10a7). Contractor Generated Va Patient Records Are The Property Of The Va And Shall Not Be Accessed, Released, Transferred, Or Destroyed Except In Accordance With Applicable Laws And Regulations. Contractor Shall Ensure That All Records Pertaining To Medical Care And Services Provided To Va Patients Are Captured In The Va Electronic Health Record System As Required By Va Policy As Discussed In 4.4.4. disclosure: Contractor S Physician(s) May Have Access To Patient Medical Records For The Purpose Of Providing Medical Care And Services To Va Patients And Performing Services Under The Contract; However, Contractor Shall Obtain Permission From The Va Before Disclosing Any Patient Information Outside Va. Va Authorizes The Contractor To Discuss Patient Health Information For Coordination Of Care Within Community Health Care Providers In Compliance With Va Regulations, Hipaa And Vha Directive 1605.1, Privacy And Release Of Information. The Va Will Provide The Contractor With A Copy Of Vha Directive 1907.01, Health Information Management And Health Records And Vha Directive1605.1, Privacy And Release Of Information. The Penalties And Liabilities For The Unauthorized Disclosure Of Va Patient Information Mandated By The Statutes And Regulations Mentioned Above, Apply To The Contractor. professional Standards For Documenting Care: Care Shall Be Appropriately Documented In Medical Records In Accordance With Standard Commercial Practice And Guidelines Established By Vha Directive 1907.01 Health Information Management And Health Records: Https://www.va.gov/vhapublications/viewpublication.asp?pub_id=9235 And All Guidelines Provided By The Facility. release Of Information: The Va Shall Maintain Control Of Releasing Any Copies Of Patient Health Information Or Health Records And Will Follow Policies And Standards As Defined, But Not Limited To Privacy Act Requirements. The Contractor Will Not Release Or Disclose Copies Of Records And Will Refer All Such Requests To The Release Of Information Department At The Va Facility Where Assigned. management For Medical Records: National Archives And Records Administration Record Disposition Requirements Are Found In Rcs 10-1 Chapter 6, 6000 Series. direct Patient Care: 100% Of The Time Involved In Direct Patient Care. Contractor Shall Be Responsible For: scope Of Care: Contractor S Physician(s) Shall Be Responsible For Providing General Surgery Physician Care, Including, But Not Limited To: clinic Responsibilities: Contractor Physician(s) Shall Be Present On Time For Any Scheduled Clinics/surgeries Start Times As Documented By Physical Presence In The Clinic Or Or At The Scheduled Start Time. communication Of Test Results: Mechanisms Must Be In-place To Provide Notification Of Test Results For Patients Receiving Care In Accordance With Vha Directive 1088, Communicating Test Results To Providers And Patients. medications: Contractor S Physician(s) Shall Follow All Established Medication Policies And Procedures. No Sample Medications Shall Be Provided To Patients. discharge Education: Provide Discharge Education And Follow Up Instructions That Are Coordinated With The Next Care Setting For All General Surgery Clinical Or Surgical Patients. (not Applicable) qa/qi Documentation: The Contractor S Physician(s) Shall Complete The Appropriate Qm/pi Documentation Pertaining To All Procedures, Complications And Outcome Of Examinations. patient Safety Compliance And Reporting: Contractor S Physician(s) Shall Follow All Established Patient Safety And Infection Control Standards Of Care. Contractor S Physician(s) Shall Make Every Effort To Prevent Medication Errors, Falls, And Patient Injury Caused By Acts Of Commission Or Omission In The Delivery Of Care. All Events Related To Patient Injury, Medication Errors, And Other Breeches Of Patient Safety Shall Be Documented In The Medical Record Of Those Impacted And Disclosed To The Patient Or Surrogate. As Soon As Practicable (but Within 24 Hours) Contractors Shall Notify Cor Of Incident And Submit An Entry In The Va Patient Safety Reporting System, Following Up With Cor As Required Or Requested. performance Standards, Quality Assurance (qa) And Quality Improvement(qi): quality Management/quality Assurance Surveillance: Contract Personnel Shall Be Subject To Quality Management Measures, Such As Patient Satisfaction Surveys, Timely Completion Of Medical Records, And Peer Reviews. Methods Of Surveillance: Focused Provider Practice Evaluation (fppe) And Ongoing Provider Practice Evaluation (oppe). Contractor Performance Will Be Monitored By The Government Using The Standards As Outlined In This Pws And Methods Of Surveillance Detailed In The Qasp. The Qasp Shall Be Attached To The Resultant Contract And Shall Define The Methods And Frequency Of Surveillance Conducted. patient Complaints: The Co Will Resolve Complaints Concerning Contractor Relations With The Government Employees Or Patients. The Co Is Final Authority On Validating Complaints. If The Contractor Is Involved And Named In A Validated Patient Complaint, The Government Reserves The Right To Refuse Acceptance Of The Services Of Such Personnel. This Does Not Preclude Refusal In The Event Of Incidents Involving Physical Or Verbal Abuse. the Government Reserves The Right To Refuse Acceptance Of Any Contractor Personnel At Any Time After Performance Begins, If Personal Or Professional Conduct Jeopardizes Patient Care Or Interferes With The Regular And Ordinary Operation Of The Facility. Breaches Of Conduct Include Intoxication Or Debilitation Resulting From Drug Use, Theft, Patient Abuse, Dereliction Or Negligence In Performing Directed Tasks, Or Other Conduct Resulting In Formal Complaints By Patient Or Other Staff Members To Designated Government Representatives. Standards For Conduct Shall Mirror Those Prescribed By Current Federal Personnel Regulations. The Co And Cor Shall Deal With Issues Raised Concerning Contractor S Conduct. The Final Arbiter On Questions Of Acceptability Is The Co. performance Standards: measure: Provider Quality Performance performance Requirement: All Contractor S Physician(s) Shall Perform In Accordance With Clinical Standards standard: Oppe Documentation For All (100%) Staff Providing Services Under The Contract. All Staff (100%) Meet Standards aql: 100% Meet Standards surveillance Method: Oppe Data Pertinent To Care Performed For Each Provider Working Under This Contract. Oppe Data Will Review The Following Elements: patient Care Performance medical/clinical Knowledge practiced Based Learning And Improvement interpersonal And Communication Skills professionalism system Based Practice frequency: Annual measure: Qualifications Of Key Personnel performance Requirement: All Contractor S Physician(s) Shall Be Board Certified/board Eligible Accordance With Abs Standards For General Surgery standard: All (100%) Contractor S Physician(s) Are Board Certified/board Eligible aql: 100% surveillance Method: Periodic Inspection Of Qualification Documents frequency: Bi-annually measure: Scope Of Practice/privileging performance Requirement: Contractor S Physician(s) Perform Within Their Individual Scopes Of Practice/privileging standard: All (100%) Contractor S Physician(s) Perform Within Their Scope Of Practice/privileges 100% Of The Time aql: 100% Contractor S Physician(s) Perform Within Their Scope Of Practice/privileges 100% Of The Time surveillance Method: Random Sampling Of Records frequency: Every 6 Months measure: Patient Access performance Requirement: The Contractor Shall Provide Contractor S Physician(s) In Accordance With The Operating Hours And Va Clinical Schedule Outlined In This Pws standard: All (100%) Contractor S Physician(s) Are On Time And Available To Perform Services aql: Contractor S Physician(s) Is On-time And Available To Perform Services 95% Of The Time surveillance Method: Periodic Inspection Of Time And Attendance Sheets frequency: Daily measure: Patient Safety performance Requirement: Patient Safety Incidents Shall Be Reported Using Va Patient Safety Reporting System. All Incidents Reported Immediately (within 24 Hours.) standard: All (100%) Of Patient Safety Incidents Are Reported Using Va Patient Safety Reporting System Within 24 Hours Of Incident aql: 100% Of Patient Safety Incidents Are Reported Using Va Patient Safety Reporting System Within 24 Hours Of Incident surveillance Method: Periodic Inspection frequency: Daily measure: Maintains Licensing, Registration, And Certification performance Requirement: Updated Licensing, Registration And Certification Shall Be Provided As They Are Renewed. Licensing And Registration Information Kept Current standard: All (100%) Licensing, Registration(s) And Certification(s) For Contractor S Physician(s) Shall Be Provided As They Are Renewed. Licensing And Registration Information Kept Current aql: 100% Licensing, Registration(s) And Certification(s) For Contractor S Physician(s) Shall Be Provided As They Are Renewed. Licensing And Registration Information Kept Current. No Acceptable Deviation. surveillance Method: Periodic Inspection frequency: Annually measure: Mandatory Training performance Requirement: Contractor Shall Complete All Required Training On Time Per Facility Policy standard: All (100%) Of Required Training Is Complete On Time By Contractor S Physician(s) aql: 95% Completions surveillance Method: Periodic Inspection Or Random Sampling frequency: Annually measure: Privacy, Confidentiality And Hipaa performance Requirement: Contractor Is Aware Of All Laws, Regulations, Policies And Procedures Relating To Privacy, Confidentiality And Hipaa And Complies With All Standards Zero Breaches Of Privacy Or Confidentiality standard: All (100%) Contractor S Physician(s) Comply With All Laws, Regulations, Policies And Procedures Relating To Privacy, Confidentiality And Hipaa aql: 100% Compliance surveillance Method: Periodic Inspection; Contractor Shall Provide Evidence Of Annual Training Required By The Facility, Reports Violations Per Va Handbook 6500.6 frequency: Annually registration With Contractor Performance Assessment Reporting System as Prescribed In Far Part 42.15, The Va Evaluates Contractor Past Performance On All Contracts That Exceed The Simplified Acquisition Threshold And Shares Those Evaluations With Other Federal Government Contract Specialists And Procurement Officials. The Far Requires That The Contractor Be Provided An Opportunity To Comment On Past Performance Evaluations Prior To Each Report Closing. To Fulfill This Requirement Va Uses An Online Database, Cpars, Which Is Maintained By The Naval Sea Logistics Center In Portsmouth, New Hampshire. Cpars Has Connectivity With The Past Performance Information Retrieval System (ppirs) Database, Which Is Available To All Federal Agencies. Ppirs Is The System Used To Collect And Retrieve Performance Assessment Reports Used In Source Selection Determinations And Completed Cpars Report Cards Transferred To Ppirs. Cpars Also Includes Access To The Federal Awardee Performance And Integrity Information System (fapiis). Fapiis Is A Web-enabled Application Accessed Via Cpars For Contractor Responsibility Determination Information. each Contractor Whose Contract Award Is Estimated To Exceed The Simplified Acquisition Threshold Requires A Cpars Evaluation. A Government Focal Point Will Register Your Contract Within Thirty Days After Contract Award And, At That Time, You Will Receive An Email Message With A User Id (to Be Used When Reviewing Evaluations). Additional Information Regarding The Evaluation Process Can Be Found At Www.cpars.gov Or If You Have Any Questions, You May Contact The Customer Support Desk @ Dsn: 684-1690 Or Comm: 207-438-1690. for Contracts With A Period Of One Year Or Less, The Co Will Perform A Single Evaluation When The Contract Is Complete. For Contracts Exceeding One Year, The Co Will Evaluate The Contractor S Performance Annually. Interim Reports Will Be Filed Each Year Until The Last Year Of The Contract, When The Final Report Will Be Completed. The Report Shall Be Assigned In Cpars To The Contractor S Designated Representative For Comment. The Contractor Representative Will Have Sixty (60) Days To Submit Any Comments And Re-assign The Report To The Co. failure For The Contractor S Representative To Respond To The Evaluation Within Those Sixty (60) Days, Will Result In The Government S Evaluation Being Placed On File In The Database With A Statement That The Contractor Failed To Respond; The Contractor S Representative Will Be Locked Out Of The Evaluation And May No Longer Send Comments. government Responsibilities: va Support Personnel, Services Or Equipment: Not Needed contract Administration/performance Monitoring: After Award Of Contract, All Inquiries And Correspondence Relative To The Administration Of The Contract Shall Be Addressed To: (enter Contract Administration If Not Already Listed In Another Area- List The Title (not Name) And Contact Information For Cor, Clinical Point Of Contact, And Any Other Relevant Personnel Involved). co Responsibilities: the Co Is The Only Person Authorized To Approve Changes Or Modify Any Of The Requirements Of This Contract. The Contractor Shall Communicate With The Co On All Matters Pertaining To Contract Administration. Only The Co Is Authorized To Make Commitments Or Issue Any Modification To Include (but Not Limited To) Terms Affecting Price, Quantity Or Quality Of Performance Of This Contract. the Co Shall Resolve Complaints Concerning Contractor Relations With The Government Employees Or Patients. The Co Is Final Authority On Validating Complaints. In The Event The Contractor Effects Any Such Change At The Direction Of Any Person Other Than The Co Without Authority, No Adjustment Shall Be Made In The Contract Price To Cover An Increase In Costs Incurred As A Result Thereof. in The Event That Contracted Services Do Not Meet Quality And/or Safety Expectations, The Best Remedy Will Be Implemented, To Include But Not Limited To A Targeted And Time Limited Performance Improvement Plan; Increased Monitoring Of The Contracted Services; Consultation Or Training For Contractor Personnel To Be Provided By The Va; Replacement Of The Contract Personnel And/or Renegotiation Of The Contract Terms Or Termination Of The Contract. cor Responsibilities: the Cor Shall Be The Va Official Responsible For Verifying Contract Compliance. After Contract Award, Any Incidents Of Contractor Noncompliance As Evidenced By The Monitoring Procedures Shall Be Forwarded Immediately To The Co. the Cor Will Be Responsible For Monitoring The Contractor S Performance To Ensure All Specifications And Requirements Are Fulfilled. Quality Improvement Data That Will Be Collected For Ongoing Monitoring Includes But Is Not Limited To: Enter Data That May Be Collected. the Cor Will Maintain A Record-keeping System Of Services By Electronical Fileinvoice Payment Process System (ipps). The Cor Will Review This Data Monthly When Invoices Are Received And Certify All Invoices For Payment By Comparing The Hours Documented On The Va Record-keeping System And Those On The Invoices. Any Evidence Of The Contractor's Non-compliance As Evidenced By The Monitoring Procedures Shall Be Forwarded Immediately To The Co. the Cor Will Review And Certify Monthly Invoices For Payment. If In The Event The Contractor Fails To Provide The Services In This Contract, Payments Will Be Adjusted To Compensate The Government For The Difference. all Contract Administration Functions Will Be Retained By The Va. special Contract Requirements: reports/deliverables: The Contractor Shall Be Responsible For Complying With All Reporting Requirements Established By The Contract. Contractor Shall Be Responsible For Assuring The Accuracy And Completeness Of All Reports And Other Documents As Well As The Timely Submission Of Each. Contractor Shall Comply With Contract Requirements Regarding The Appropriate Reporting Formats, Instructions, Submission Timetables, And Technical Assistance As Required. the Following Are Brief Descriptions Of Required Documents That Must Be Submitted By Contractor: Upon Award; Weekly; Monthly; Quarterly ; Annually, Etc. Identified Throughout The Pws And Is Provided Here As A Guide For Contractor Convenience. If An Item Is Within The Pws And Not Listed Here, The Contractor Remains Responsible For The Delivery Of The Item. note To Contracting: These Items Must Be Described In 52.212-1 Addendum To Instructions To Offerors what submit As Noted submit To quality Control Plan: Description And Reporting Reflecting The Contractor S Plan For Meeting Of Contract Requirements And Performance Standards upon Proposal And As Frequently As Indicated In The Performance Standards co other Than Cost And Price Information Supporting Proposed Physician Rate (required For Affiliate Onsite Hourly- Remove If It Does Not Apply) upon Proposal, To Submit Epa Request, Upon Change In Key Personnel co copy Of Subcontracting Plan Is Required For All Large Businesses. Copy Of Contractor Certification Statement If No Subcontracting Possibilities Exist upon Proposal And As Updated co copies Of Any And All Licenses, Board Certifications, Npi, To Include Primary Source Verification Of All Licensed And Certified Staff upon Proposal And Upon Renewal Of Licenses And Upon Renewal Of Option Periods Or Change Of Key Personnel co With Proposal; Renewal Submitted To Vetpro System certification That Staff List Has Been Compared To Oig List upon Proposal And Upon New Hires co proof Of Indemnification And Medical Liability Insurance upon Proposal And Upon Renewals co certificates Of Completion For Cyber Security And Patient Privacy Training Courses before Receiving An Account On Va Network And Annual Training And New Hires. co acls/bls Certification upon Award And Every Two Years After Award cor contingency Plan For Replacing Key Personnel To Maintain Services As Required Under The Terms Of The Contract upon Proposal And As Updated cor billing: invoice Requirements And Supporting Documentation: Supporting Documentation And Invoice Must Be Submitted No Later Than The Last Workday Of The Month. Subsequent Changes Or Corrections Shall Be Submitted By Separate Invoice. In Addition To Information Required For Submission Of A Proper Invoice In Accordance With Far 52.212-4 (g), All Invoices Must Include: name And Address Of Contractor invoice Date And Invoice Number contract Number And Purchase/task Order Number date Of Service contractor S Physician(s) (name Of Contractor S Employee) hourly Rate quantity Of Hours Worked total Price vendor Electronic Invoice Submission Methods: invoices Will Be Electronically Submitted To The Tungsten Website At Https://www.tungstenautomation.com/. Tungsten Automation Direct Vendor Support Number Is 877-489-6135 For Va Contracts. The Va-fsc Pays All Associated Transaction Fees For Va Orders. During Implementation (technical Set-up) Tungsten Automation Will Confirm Your Taxpayer Id Number With The Va-fsc. This Process Can Take Up To 5 Business Days To Complete To Ensure Your Invoice Is Automatically Routed To Your Certifying Official For Approval And Payment. To Successfully Submit An Invoice To Va-fsc Please Review How To Create An Invoice Within The How To Guides. All Invoices Submitted Through Tungsten Automation To The Va-fsc Should Mirror The Current Submission Of Invoice. Clarification Of Additional Requirements Should Be Confirmed With Your Certifying Official (your Co Or Buyer). Payment Will Only Be Made For Actual Services Rendered. Payments Shall Be Made Monthly In Arrears. The Va-fsc Requires Specific Information In Compliance With The Prompt Pay Act And Business Requirements. The Contractor Shall Be Reimbursed Upon Receipt Of A Proper Invoice. For Additional Information, Please Contact: tungsten Support phone: 1-877-489-6135 website: Https://www.tungstenautomation.com/ department Of Veterans Affairs Financial Service Center https://www.fsc.va.gov/einvoice.asp â  reduction In Services: This Is A Fixed Quantity Contract For A Specified Number Of Hours. If, At The End Of The Pop, The Government Has Not Utilized The Total Number Of Hours Required Under This Contract Because Of A Change In Its Requirements, The Parties Agree That They Will Attempt To Negotiate In Good Faith A Contract Modification Reducing The Scope Of The Contract With A Corresponding Adjustment In The Total Contract Price. In No Event Will The Va Pay For Hours That Exceed The Total Number Of Hours Specified In The Contract For The Pop. payments In Full/no Billing Va Beneficiaries: The Contractor Shall Accept Payment For Services Rendered Under This Contract As Payment In Full. Va Beneficiaries Shall Not Under Any Circumstances Be Charged Nor Their Insurance Companies Charged For Services Rendered By The Contractor, Even If Va Does Not Pay For Those Services. This Provision Shall Survive The Termination Or Ending Of The Contract. to The Extent That The Veteran Desires Services Which Are Not A Va Benefit Or Covered Under The Terms Of This Contract, The Contractor Must Notify The Veteran That There Will Be A Charge For Such Service And That The Va Will Not Be Responsible For Payment. the Contractor Shall Not Bill, Charge, Collect A Deposit From, Seek Compensation, Remuneration, Or Reimbursement From, Or Have Any Recourse Against, Any Person Or Entity Other Than Va For Services Provided Pursuant To This Contract. It Shall Be Considered Fraudulent For The Contractor To Bill Other Third-party Insurance Sources (including Medicare) For Services Rendered To Veteran Enrollees Under This Contract. contractor Security Requirements (va Handbook 6500.6): Pulled From Ecms, Team Should Select Language From Each Section As Applicable.

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

Others
United States
Closing Date10 Jan 2025
Tender AmountRefer Documents 
Details: Page 14 Of 14 no Phone Calls. Send Any Responses By E-mail Only. As This Is A Sources Sought Notice For Market Research Purposes, The Government Will Not Accept Any Technical Questions At This Time. this Is A Sources Sought Notice To Determine Small Business Sources Capable Of Providing Hazardous Waste Management Services Per This Notice Under Naics 562211 (hazardous Spill Containment And Clean-up Equipment And Material). Small Business Size Standard Is $47 Million. Product Service Code (psc) Is 4235 (hazardous Waste Treatment And Disposal). background: this Is A Sources Sought Notice Being Released Pursuant To Federal Acquisition Regulation (far) Part 10: Market Research. This Notice Is Issued Solely For Informational, Market Research, And Planning Purposes Only. It Does Not Constitute A Solicitation Or A Promise To Issue A Solicitation In The Future.â  This Notice Does Not Commit The Federal Government To Contract For Any Service At This Time. further, The U.s.t Department Of Veterans Affairs, Network Contracting Office (nco) 23/ Supply Services Team 1 Is Not At This Time Seeking Offers And Will Not Accept Unsolicited Offers.â  respondents Are Advised That The Federal Government Will Not Pay For Any Information Or Administrative Costs Incurred In Response To This Notice. All Costs Associated With Responding To This Notice Will Be Solely At The Responding Party S Expense. responses To This Notice Are Not Offers And Cannot Be Accepted By The Federal Government To Form A Binding Contract.â  Although The Term Offeror Is Used In This Notice, Your Respective Organization S Response Will Be Treated As Information Only And Shall Not Be Used As An Offer. objective: the Objective Of This Notice Is To Conduct Market Research To Determine If There Are Service Disabled Veteran Owned Small Business (sdvosb) Or Veteran Owned Small Business (vosb) Sources, Or Any Other Small Businesses Capable Of Providing Hazardous Waste Management Services For The St. Cloud, Mn Va Hcs. description Of Service: see Attached Proposed Statement Of Work. places Of Performance: see Attached Proposed Statement Of Work. potential Scope Of Work: see Attached Proposed Statement Of Work. potential Certifications And Licensure: see Attached Proposed Statement Of Work. submittal Of Responses: responses Shall Be Sent Via Electronic Mail Only By 5:00 Pm Central Standard Time (cst), 1-10-2025 To: amanda Patterson-elliott contracting Specialist e-mail: Amanda.patterson-elliott@va.gov offerors Shall Submit A Capability Statement Indicating Their Ability And Experience To Provide The Services Cited Above; Such Statement Shall Also List: name Of Offeror address Of Offeror uei Number Of Offeror point Of Contact Name, Phone Number, And E-mail Of Offeror whether Or Not Vendor Is Sdvosb Or Vosb; Sdvosb And Vosb Will Be Verified Through Vet Biz At Https://veterans.certify.sba.gov/ . whether Or Not Vendor Has General Services Administration (gsa) Federal Supply Schedule (fss) Contract; If So, Please Provide Gsa Fss Contract Number Certifications And Licensure That Its Applicable Staff Holds disclaimer This Rfi Is Issued Solely For Information And Planning Purposes Only And Does Not Constitute A Solicitation. All Information Received In Response To This Rfi That Is Marked As Proprietary Will Be Handled Accordingly. In Accordance With Far 15.201(e), Responses To This Notice Are Not Offers And Cannot Be Accepted By The Government To Form A Binding Contract. Responders Are Solely Responsible For All Expenses Associated With Responding To This Rfi. statement Of Work title: Hazardous Waste Management Services overview: The St. Cloud Va Has A Need For A Qualified Contractor With The Capability And Capacity To Provide Disposal Services For Hazardous Waste, Non-hazardous Chemical Waste, Specialty Waste (i.e. Hazardous Pharmaceutical, High Hazardous Waste, Dea Drug Waste, Non-hazardous Pharmaceutical, And Dual Waste [hazardous Chemical And Bio-hazardous Combined]), Universal Waste, Emergency Spill Response Services, Lab Pack Services That Include Supplies, Labeling, Lab-packing, Consolidation, Shipment, Manifesting, And Consulting. this Contract Will Not Include The Disposal Of Infectious, Bio-hazardous, Radiological, Or Pathological Waste Except For Dual (chemical And Infectious Combined) Waste. acronyms: a. Co Contracting Officer b. Cor Contracting Officer S Representative c. Va Department Of Veterans Affairs d. Vahcs St. Cloud Va Health Care System e. Sow Statement Of Work f. Osha - Occupational Safety And Health Administration g. Epa - Environmental Protection Agency h. Dot Department Of Transportation i. Mpca Minnesota Pollution Control Agency j. Jc Joint Commission k. Mdh Minnesota Department Of Health l. Cdc Centers For Disease Control m. Dea Drug Enforcement Administration n. Rcra Resource Conservation And Recovery Act o. Cfr Code Of Federal Regulations p. Contractor Employee Means All Contractor Staff, Technicians, Personnel, Subcontractors Or Persons Working On Behalf Of The Contractor. 4. Place Of Performance: st. Cloud Va Health Care System, 4801 Veterans Drive, St. Cloud, Mn 56303 period Of Performance: this Contract Will Be A Single Award, Firm Fixed Price Indefinite Delivery, Indefinite Quantity, Service Contract For One (1) Base Year From 02/01/2025 01/31/2026 With Four (4) Option Years. Renewal Of Option Years Is Subject To Availability Of The Next Fiscal Year Funding. qualifications And Special Certifications: contractor Must Obtain All Necessary Permits And/or Licenses Regarding The Pickup And Incineration Or Other Acceptable Disposition As Regulated By State And Federal Epa Guidelines For Hospital Hazardous/dual Waste. *the Primary Contractor Must Own Their Own Licensed Treatment, Storage, And Disposal Facilities. treatment, Storage And Disposal Facilities (tsdfs) Need A Resource Conversation And Recovery Act (rcra) Permit. federal Certificate Of Registration To Transport Hazardous Waste federal Safety Permit To Travel On Highways if Waste Covered Under This Contract Must Be Transported Through A Jurisdiction Which Requires Special Licensing Or Permitting, The Contractor And/or Subcontractor Shall Obtain And Maintain All Necessary Licenses And Permits. The Contractor Shall Provide Copies Of These Licenses And Permits To The Cor. the Contractor And/or Subcontractor Shall, Without Additional Cost To The St. Cloud Vahcs Or Federal Government, Provide And Maintain All Licenses And Permits For Personnel, Trailers, Containers, Vehicles, And Other Resources Required For Proper Transportation And Disposal Of The Wastes Covered Under This Contract In Accordance With All Applicable Federal, State, Local, Municipal, And Va, Laws, Regulations, And Requirements. if Appropriate Licenses And Permits Are Not Maintained In Accordance With These Applicable Laws, Regulations And Requirements, The St. Cloud Vahcs May Terminate The Contract Effective Upon Discovery. the Contractor Is Required To Perform Characterization Of All Waste Streams Identified By Each Facility Using Process Knowledge, Identity Of The Chemicals, And Other Types Of Chemical Analysis Including But Not Limited To Toxicity Characteristic Leaching Procedure (tclp). chemical Wastes Shall Include But Not Be Limited To Flammables, Corrosives, Poisons/toxics/lethal, Reactive Wastes, Dual And Hazardous Waste, And Universal Waste. Work Shall Be Performed In Accordance With All Applicable, Federal, State, Local And All Governing Regulations. the Successful Offeror Must Possess The Necessary Technical Expertise And Resources Required By This Statement Of Work To Be Considered For Contract Award. regulations / Directives / Policies: the Contractor Must Comply With All Applicable Federal (us Epa, Us Osha, Us Dot), State (mn Osha, Mpca), Interstate, National Consensus Standards (jc), And Local Requirements, Rules, Regulations, And Laws Relative To The Handling, Removal, Manifesting, Transportation, Management, Disposal And/or Treatment Of Hazardous, Non-hazardous And Specialty Wastes. the Contractor May Not Attempt To Circumvent Mn01 Lethality Waste Characteristics By Repackaging And Reprofiling In Another State. scope Of Work: contractor Shall Provide All Labor, Personnel, Transportation, Vehicles, Equipment, Tools, And Materials Necessary To Provide Hazardous Waste Management Services. contractor Shall Have The Capability And Capacity To Provide Hazardous, Dual, Universal, And Dea Drug Waste, Waste Disposal Services, Lab Packs, And Removal Of Non-hazardous Chemical Waste Removal And Disposal From The Vahcs, In Accordance With Current Federal, State, And Local Regulations. services Shall Include Pharmaceutical Formulary Review; Technical Consulting; Electronic Record Keeping; Emergency Spill Response; Analysis, Documentation, Waste Treatment, Disposal And Support Services Required To Categorize, Package, Transport, Document And Dispose Of Hazardous, High Hazardous, Dual, And Universal, And Non-hazardous Chemical Wastes And Their Containers. the Certification And Accreditation Requirements Under Va Handbook 6500 Do Not Apply, And As Such A Security Accreditation Package Is Not Required. wate Removal And Shipment: the Contract Will Include Removal, Documentation, And Shipment Of Wastes From The Designated Hazardous Waste Storage Area At The St. Cloud Va Hcs. this Will Include Periodic Shipments Of Dea Controlled Substances Waste And All Labor And Equipment To Package, Transport, Treat And Dispose Of Waste. Protection And Mandates: contractor Will Provide Appropriate Protection For His/her Employees To Be Within Cdc Guidelines That Include Barrier Precautions, I.e., Gloves, Masks, Eyewear And/or Waterproof Gowns, Aprons, (lab) Coats Or Respirators As Necessary. cor Or Cor Designee Will Notify Contractor Of Areas With The Health Care Systems Or Unusual Circumstances Requiring Personal Protective Equipment (ppe) Beyond Standard Practices. contractor Will Comply With All Applicable Osha, Mpca, The Joint Commission, Mdh, Federal, State, Interstate And Local Requirements, Rules, Regulations, And Laws Respecting Control And Abatement Of Pharmaceutical And Hazardous Waste Disposal And Management. obtain All Necessary Permits And/or Licenses Regarding The Pickup And Incineration Or Other Acceptable Disposition As Regulated By State And Federal Epa Guidelines For Hospital Hazardous/dual Waste. this Includes Any Laws In Other States That Are Applicable To The Transportation Of Hazardous/dual Waste Across State Lines. potential Successful Contractor May Be Asked For Documentation That Will Help Determine Contractor Responsibility And Whether The Transporter Is Aware Of And In Compliance With (these) Regulatory Requirements. the Vahcs Requires Hazardous Waste Removal At A Minimum Of Six (6) Visits Per Year/every Other Month. contractor Must Check In With The Cor Or His/her Designee Prior To Beginning Any Work And After Completion. shipments Of Hazardous, Dual, Universal, And Non-hazardous Healthcare Waste Must Be Provided Every Other Month, Or As Needed Based On Generation. periodic Shipments Of Dea Controlled Substances Waste. all Labor And Equipment To Package, Transport, Treat And Dispose Of Waste. technical Expertise To Categorize And Profile Waste And Advise On Federal, State, Municipal And Local Regulatory Compliance. consulting Services at The St. Cloud Va S Request, The Contractor Will Provide Technical Expert Consulting Services On Topics Related To Epa, State Specific Rcra, Dot, And Other Environmental Regulations. pharmaceutical Formulary Review Annual Update annual Pharmaceutical Formulary Review And Report That Identifies All Listed And Characteristic Waste And Codes Including Minnesota Specific Waste Codes. the Contractor Will Provide An Electronic Review Of The Vahcs Formulary And Provide Recommendations As Appropriate. the Completed Review Will Identify All Listed Waste, Characteristic Waste, And Rcra-equivalent Waste, Including State Specific Waste Codes, E.g. Mn01 Lethal. the Final Review Will Be Submitted In Microsoft Excel Spreadsheet In An Electronic File. electronic Record Keeping And Reporting. controlled Substances Disposal contractor Personnel Will Be Escorted By Vahcs Staff. the Contractor Will Be Responsible For The Disposal Of Controlled Substances From The St. Cloud Va Hcs Pharmacy In Compliance With All Applicable Dea, Epa, Mpca, And Local Regulations And The Needs Of The Department Of Veterans Affairs. transportation: Hazardous Waste Shall Be Transported On The Public Highways In Vehicles That Are Licensed, Permitted, Or Otherwise Registered In Accordance With All Applicable Federal, State, Municipal And Local Laws. license Number(s) Must Be Posted On The Exterior Of The Vehicles. each Vehicle Transporting Hazardous Waste Must Have An Emergency Spill Clean-up Plan And Basic Cleanup Equipment On Board. out Of Country Shipments Are Prohibited Under This Contract. disposal: Contractor Will Dispose Of Hazardous Waste In A Manner That Leaves No Future Expense Potential To The Va Or The Federal Government. Chemicals Should Be Disposed Of In The Following Preferred Priority: the Treatment Of The Chemical Waste (at A Facility Approved For Such Processing By An Appropriate State Or Federal Agency) In A Manner That Renders It No Longer A Hazardous Waste As Defined In The 40 Cfr Series. These Processes Include (but Are Not Limited To): reprocessing Or Recovery Followed By Recycling/reuse. chemical Neutralization Or Detoxification. thermal Treatment (e.g. Incineration, Pyrolysis). the Long-term Internment (burial) In A Secure Chemical Landfill Site Approved For Such By The Appropriate State Or Federal Agency. acceptance Of The Hazardous Property (chemical Wastes) At A Properly Permitted Treatment, Storage, Or Disposal Site Does Not Constitute Disposal And/or Completion Of The Contract. it Is The Prime Contractor S Responsibility To Obtain All Necessary Documentation To Prove That The Timely End Disposal Of All Items Has Been Accomplished. contractor Shall Provide The Cor With A List Of Disposal Facilities That Will Be Used In Conjunction With This Contract. This List Must Include The Name Of The Company, Address, City, And State, Zip Code, Telephone Number, Epa Id And State Permit Number. this Contract Will Not Include The Disposal Of Infectious, Bio-hazardous, Radiological, Or Pathological Waste With The Exception Of Dual (chemical And Infectious Combined) Waste. waste Spill Or Release: Should Waste Be Spilled Or Released During The Performance Of Services, Through No Fault Of The St. Cloud Va Hcs, The Contractor Will Be Responsible For Cleanup And All Costs Associated With The Satisfactory Remediation Of The Incident. this Will Include The Cost Of All Labor And Materials, Repair Of Any Damage, And/or Harm Caused To Patients, Visitors, And Staff. Cleanup Shall Be Performed To The Satisfaction Of Regulatory Authorities And The Cor. when Waste Is Spilled Or Release By The Contractor During The Performance Of Services The Contractor Shall Submit A Spill Report. such Incidents Shall Be Reported To The Cor Immediately By Telephone And In Writing No Later Than Seven (7) Workdays After Leaving The Site. the Spill Report Shall List At A Minimum The Type Of Spill, Amount Of Waste, And Personnel Exposed To The Spilled Waste. the Contractor Shall Provide Certification That The Spill Was Cleaned Up, A Statement Concerning The Effect On Any Employees, And A Description Of The Cause And Corrective Measure Instituted By Contractor To Ensure Spills Do Not Occur Again. Schedule: the Contractor And Cor Will Arrange For Scheduled/routine (non-emergency) Services That Occur On A Bi-monthly Basis. work Hours: the Contractor Shall Perform Services During Normal Business Hours, 8:00 Am - 4:30 Pm, Monday Through Friday, Excluding Federal Holidays. The Eleven National Holidays Observed By The Federal Government Are: New Years Day January 1st Martin Luther King Jr. Day Third Monday In January Presidents Day Third Monday In February Memorial Day Last Monday In May Juneteenth June 19th Independence Day July 4th Labor Day First Monday In September Columbus Day Second Monday In October Veterans Day November 11th Thanksgiving Day Fourth Thursday In November Christmas Day December 25th Any Additional Federal Holiday Declared By The President Of The United States if The Holiday Falls On A Saturday, The Previous Friday Will Be Observed And If The Holiday Falls On A Sunday, The Following Monday Will Be Observed. the Cor Or Dot Hazmat Certified Designee Are Available During Those Hours For The Approval/signature Of Shipping Manifests And Other Required Documentation Unless Exigent Circumstances Require Services During An Unscheduled Time. any Service Performed Outside Of Normal Working Hours Shall Be Approved In Advance By The Contracting Officer S Representative Cor. after-hours Access Will Be Coordinated With The Gems Program Manager Or The Gems Program Manager S Site Designee. emergency Services: the Contractor Must Be Available 24/7 And Will Take Responsibility For Up To Two (2) Chemical Spills/releases Per Year At The St. Cloud Va Hcs. the Contractor Shall Provide A Primary And Alternate Point Of Contact To The Cor Within 5 Days Of Contract Award. Information Shall Include A 24-hour Emergency Contact (name, Telephone #, Mobile #) Available During Contractor S Non-business Hours. training For Contractor Personnel: the Contractor S On-site Staff Shall Have Training In Hazardous Waste Handling And Emergency Procedures And Provide Documentation Of This Training. this Training Shall Include Osha, Epa, Minnesota Pollution Control, And Dot (including Hm 181) Regulations. permits, Licenses, And Regulatory Compliance: the Contractor Shall Maintain All Applicable Permits And Licenses For Services Provided And Comply With All Applicable Federal, State, Municipal And Local Laws, Rules, And Regulations. the Contractor Will Obtain And Maintain Any Additional Permits And Licenses That May Be Required Because Of Changes In Regulations. this Includes Compliance With All Occupational Safety And Health Administration (osha), Environmental Protection Agency (epa), Minnesota Pollution Control Agency (mpca), Joint Commission (jc), Minnesota Department Of Health (mdh) Requirements And Requirements In Other States Applicable To The Transportation And Disposal Of Waste That Crosses State Lines. the Following Shall Be Provided To The Contracting Officer With Bid Proposal Submission For Evaluation Purposes And Annually Within Thirty (30) Days Of The Renewal Date Of This Contract With Any Changes To Original Submission Clearly Identified And Highlighted: current Waste Transporter Permit(s) For The Contractor And Subcontractors. list Of All Transfer Stations, Treatment, Storage, And Disposal Facilities (tsdfs) Including Incineration, Wastewater And Sludge Treatment Facilities That Shall Be Utilized During This Contract To Include The Capacity Of These Facilities And The Waste Codes For The Waste Streams They Are Permitted To Accept By Treatment Technology. address, Phone Number And Other Contact Information Shall Be Provided. the Va Reserves The Right To Inspect Each Of These Facilities Before Approving Its Use Or At Any Time During Or After Contract Period While Va Wastes Are Present. copy Of Operator Permit(s) certificates Of Training And Experience Of Contractor/subcontractor Staff And Personnel Who Will Perform Site Work Under This Contract (all Technicians That Will Work On Va Premises Will Be Expected To Have Received At Least The Minimum Training Required By Law As Specified In 29cfr 1910-120, 40 Cfr Parts 260-265 And 49 Cfr Parts 171-178). provide The Contractor S/subcontractor Experience In Hazardous Waste Packaging, Transport, And Disposal. provide A Copy Of Us Epa Identification Number(s) Certificate For Each Business Entity Operated Or Contracted By The Contractor That Will Provide Service Regarding Any Aspect Of Va Waste Disposal Program (i.e. Storage, Transfer, Incinerator Sites.) provided A Copy Of Certificate Of Registration With The State Epa As A Hazardous Waste Hauler For Each Business Entity Operated By The Contractor That Will Provide Hazardous Waste Transportation Services For Any Aspect Of Va Waste Disposal Program. provide Written Acknowledgement Of Responsibility For Acquisition Of All Applicable Business Licenses And Permits Required By Law. contractor Shall Certify That It Acknowledges And Is In Possession Of All Required Business Licenses And Permits. provide A List Of Any Violations And/or Citations That The Contractor And Subcontractors Have Received For Non-compliance With Any Hazardous Waste Laws, Permit Requirements, And/or Osha Requirements For The Past Three Years From The Date Of Submission. contractor Shall Include Information On All Related Business Entities Including Associated Firms That Are Owned By The Contractor Or Owned By A Common Parent Company That Will Be Involved In Any Portion Of The Processing Of Va Waste Disposal Program. if No Discharge Or Violations Have Occurred, Contractor Must Provide A Statement That Certifies No Discharges Or Violations Have Occurred. provide A Plan Describing Standard Operating Procedures (sops) That Will Be Followed While Conducting Normal Hazardous Waste Management Activities. The Contractor Shall Describe: site Safety And Contingency Procedures (e.g. Spill Management). operational Procedures And Site Management Structure. supplies And Equipment Practices. material Sampling Procedures. hazard Assessment And Categorization Procedures. packing Procedures. quality Assurance And Quality Control Procedures To Ensure Materials Are Properly Identified, Categorized, And Packaged, And Paperwork Is Properly Completed. procedures For Gaining Waste Acceptance Into A Transfer/ Disposal Facility. contractor And Project Management Procedures. provide The Following Information Regarding The Hazardous Waste Fleet Owned And Operated By The Contractor: basic Description Of Transportation Services Offered And Capabilities. fleet Description Of Number, Types, And Ages Of Vehicles. description Of Service And Maintenance Programs. types Of Materials Licensed To Haul. latest Dot Or Mcs Rating (include A Copy Of The Last Inspection). the Dot/mn Dot Compliance Record. description Of Driver Qualifications Including Training Programs, And Experience. provide Evidence That Background Checks Have Been Performed On All Employees That Will Perform Any Duties Under This Contract. provide The Following Information On The Contractor's Emergency Response (er) Capabilities (or Any Changes To Original Submission): contractor's Er Policies. Er Capabilities And Experience And Limitations. type Of Er Equipment Maintained (specify If Owned Or Subcontracted And From Whom). personnel Availability, Training, And Experience. contractor's Emergency Response Procedure Shall Describe: how To Request An Emergency Response. how The Contractor Notifies Personnel And Initiates Response Action. incident Command Procedures Followed By The Contractor. er Work Practices. er Protection Of Health And Safety Practices. er Invoicing Policy. provide A Detailed Site Safety Plan That Will Be Used To Ensure That Workers And Nearby Population Will Be Adequately Protected During Packaging And Removal Operations. provide Information Identifying Any Proposed Subcontractors And Identifying Services To Be Performed By The Subcontractors. contractor Must Submit Evidence That Subcontractor Is Qualified And Legally Able To Provide Services. (all Subcontractors Must Be Approved By The Facility Gems Program Manager And Contracting Officer Prior To Performing Any Duties Under This Contract). the Government Reserves The Right To Prohibit The Contractor From Employing The Services Of A Subcontractor Who Does Not Possess The Ability To Satisfactorily Perform In Accordance With The Provisions Of This Statement Of Work. the Use Of A Subcontractor Or Subcontractors Does Not Relieve The Contractor From Any Requirements Set Forth In This Statement Of Work. the Contractor Is Responsible For Ensuring That Any Subcontractor(s) Perform In Accordance With The Terms And Conditions Of This Statement Of Work. Subcontractors Will Also Comply With (j) Of This Section. provide A List Of Names, Titles, Addresses, Telephone Numbers (including Cellular), Pager/beeper Numbers, Facsimile Numbers, And E-mail Addresses Of Key Managers, Supervisors, Customer Service, And Field Service Personnel Performing Under This Contract. provide Written Standard Operating Procedures (sops) For The Collection, Handling, Accumulation, Sampling, Lab Testing, Characterization, Packing, And Shipping Of Hazardous, Universal, And Non-hazardous Wastes. provide A Single Point Of Contact For Each Facility With Backup. provide A List Of Names, Titles, Addresses, Telephone Numbers (including Cellular), Pager/beeper Numbers, Facsimile Numbers, And E-mail Addresses Of Key Managers, Supervisors, Customer Service, And Field Service Personnel Performing Under This Contract. records And Reporting Requirements: contractor Shall Provide A Centralized Online Electronic Waste Tracking System That Is Exportable To The Va System Via Microsoft Excel Spreadsheet. the Centralized Tracking System Will Include A Centralized Database For All Waste Characterizations And Determinations, Waste Profiles, Hazardous Waste Manifests, Universal Bill Of Lading For Universal Wastes, Methods Of Final (end) Disposal, Final (end) Disposal Sites, Shipping Information, Monthly, Quarterly And Annual Waste Generation Reports By Facility, Training Records, A Tracking System For Hazardous Materials Spills And All Recordkeeping, And Reporting Needed To Operate And Manage The St. Cloud Va Hcs Hazardous Waste Management Program. the Contractor Will Be Responsible For Providing A Database That Will Be Able To Generate Reports On Hazardous Waste Activities, Waste Characterization Profiles, Annual Generation By Facility And Other Information Necessary For The Successful Operation And Management Of A Hazardous Waste Management Program. this Will Be Readily Exported To A Format Such As Microsoft Excel. prior To The Shipment Of Waste, The Contractor Will Furnish A Properly Prepared And Legible Copy Of The Appropriate Manifests And Shipping Papers. fully Executed Manifests Will Be Provided To The St. Cloud Va Hcs Within Thirty (30) Days Of Shipment. the Contractor Will Provide A Certificate Of Disposal For All Waste Disposed Clearly Indicating Proper Treatment And Disposal. 14. Safety: The Contractor Shall Take Such Safety Precautions As The Co Or Cor May Determine To Be Reasonably Necessary. the Co Or His/her Designee Will Notify The Contractor Of Any Noncompliance. the Contractor Shall, After Receipt Of Such Notice, Immediately Correct The Conditions To Which Attention Has Been Directed. such Notice, When Served In Person On The Contractor Or His/her Representative At The Site Of Work, Or Telephonically To Contractor S Designated Representative, Shall Be Deemed Sufficient For The Previously Mentioned. if The Contractor Fails Or Refuses To Comply Promptly To Satisfactorily Abate The Hazardous Condition Or Situation, The Co May Issue An Order Stopping All Or Any Part Of The Work And Hold The Contractor In Material Breach Of This Contract. 15. Work Practices And Standards: The Contractor Shall Have Established Standard Operating Procedures That Will Be Followed While Conducting Hazardous Waste Management Activities. this Includes Site Safety And Contingency Procedures, Strike Contingency Plan, Operational Procedures, Use And Maintenance Of Supplies And Equipment Procedures, Material Sampling Procedures, Waste Categorization Procedures, Packaging Procedures, Quality Assurance Plan, Procedures For Gaining Waste Acceptance Into A Facility, And Project Management Procedures. 16. Quality Assurance: The Contractor Shall Maintain A Quality Assurance Program To Assure Services Are Performed In Accordance With Commonly Accepted Commercial Practices. the Contractor Shall Implement Procedures To Identify, Prevent, And Ensure Non-recurrence Of Defective Services. as A Minimum, The Contractor Shall Develop Quality Control Procedures Addressing The Areas Identified In The Next Paragraph. timely Shipment Of Hazardous, Dual, Universal, And Non-hazardous Healthcare Waste And Dea Controlled Substances Waste. timely And Properly Completed Manifest And Shipping Papers. sufficient And Competent Personnel Including Personnel With Expertise To Perform Waste Characterizations, Profiles, And Consultation Services. sufficient Equipment And Supplies In Good Working Condition. fully Functional Online Record Keeping And Reporting System Accessible Always. timely And Accurate Billing System. the Government Will Periodically Evaluate The Contractor Performance By Appointing A Representative(s) To Monitor Performance To Ensure Services Are Received. the Government May Inspect Each Task As Completed Or Increase The Number Of Quality Control Inspections If Deemed Appropriate. likewise, The Government May Decrease The Number Of Quality Control Inspections If Performance Dictates. 17. Competent Personnel: Contractor Personnel Who Perform Services For The St. Cloud Va Hcs Must Be Competent, Experienced, And Qualified To Perform Such Services. all Work Shall Be Performed In Accordance With Established Waste Management Practices. appropriate Handling Of Waste Is Essential For The Safety Of Government And Contractor Employees And Cost Containment. the Contractor Shall Furnish And Ensure All Personal Protective Equipment (ppe) For Contractor Employees Is In Good Condition. the Contractor Shall Provide Employee Training On Established Policies And Procedures For Waste Handling. contractor Employees Providing Site Services Shall Be Certified In Forty (40) Hour Hazardous Waste Operations And Emergency Response (hazwoper) Training And Wear Appropriate Protective Equipment When Handling Hazardous Waste. the Contractor Shall Submit Proof Of Appropriate Training And Experience To The Cor Upon Request. contractor Employees Should Be Enrolled In A Medical Surveillance Program That Meets The Standards Of 29 Cfr 1910 At The Expense Of The Contractor. 18. Identification, Check-in, Parking And Smoking: Contractor Employees Shall Notify Cor Or Designees Upon Arrival To Campus And Prior To Commencement Of Work. during Off-hours Emergency Response Activities Contractor Personnel Should Check In With Va Police If The Cor Or Designee Is Not Available. smoking Is Prohibited On Va Property. possession Of Weapons Or Contraband Is Prohibited. enclosed Containers, Including Tool Kits, Shall Be Subject To Search. 19. Indemnification: It Shall Be Expressly Agreed And Understood By The Contractor And The St. Cloud Va Hcs That The Contractor Agrees To Indemnify The St. Cloud Va Hcs Against All Liabilities, Claims, Penalties, Incident Of Death, Bodily Injuries, Destruction Or Damage To Property, Contamination Or Adverse Effects On The Environment Or Any Violation Of Government Laws, Rules Or Regulations, Caused In Whole Or Part By The Contractor S Breach Of Any Term Of The Contract Or Any Negligent Or Willful Act Or Omission Of The Contractor, Its Employees Or Subcontractors In The Performance Of This Contract. 20. Penalties And Fines: The Contractor Shall Satisfy All Applicable Regulatory Agency Requirements. in The Event A Regulatory Agency Assesses A Monetary Fine Against The St. Cloud Va Hcs For Violations Caused By The Contractor, The Contractor Shall Reimburse The St. Cloud Va For The Fine. 21. Authorized Services: Only The Services Specified In The Sow Will Be Authorized Under The Contract. the Co In Consultation With The Cor May Authorize Additional Services Or Repairs Under A Separate Purchase Authorization. reimbursement Will Not Be Made Unless Prior Authorization Is Obtained. 22. Invoices And Payment: Payment Of Services Rendered Under This Contract Will Be Made In Arrears Upon Satisfactory Completion Of Each Service And Receipt Of A Properly Prepared Invoice. invoice Must Include, But Not Limited To: contract Number purchase Order Number manifest Number(s) complete And Accurate Description Of Services dates Of Performance amounts unit Price extended Totals any Other Data Relevant For Payment Purposes the Government Shall Not Authorize Payment Until Such Time That The Cor Or His/her Designee Receives All Properly Executed And Signed Documentation. 23. Insurance: Owners And Contractor S Insurance: The Contractor Shall Obtain At His Own Expense, General Liability Insurance In The Amount Of Not Less Than $500,000.00 For Protection Against Claims Of Personal Injury, And $50,000.00 Per Occurrence For Damage To Property, Arising Out Of This Contract. professional Liability Insurance: The Contractor Shall Obtain At His Own Expense, Professional Liability Insurance For Services To Be Performed Pursuant To This Contract, Insuring The Contractor Against Malpractice Or Errors And Omissions Of The Contractor In The Amount Required By State And Local Authorities. $10 Million In Pollution Control Liability Insurance. workers Compensation And Employer Liability: $100,000.00 automobile Liability: $200,00.00 Per Person And $500,000.00 Per Occurrence For Bodily Injury And $20,000 Per Occurrence For Property Damage. at All Times During Performance, The Contractor Shall Maintain With The Contracting Officer, A Current Certificate Of Insurance Showing At A Minimum, The Insurance Required Above, And Providing Thirty (30) Days Written Notice To The Contracting Officer By The Insurance Company Prior To Cancellation Or Material Change In Policy Coverage. note: Any Additional Charges Claimed Must Be Approved By The Contracting Officer In Writing Before Service Is Completed!
321-330 of 324 archived Tenders