Hvac Tenders

Hvac Tenders

DEPT OF THE ARMY USA Tender

Other Consultancy Services...+1Consultancy Services
United States
Closing Date4 Mar 2024
Tender AmountRefer Documents 
Details: A Market Survey Is Being Conducted To Determine If There Are A Reasonable Number Of Interested Small Business Concerns To Set This Future Project Aside For Them. If Your Firm Is A Small Business, Certified Hubzone, 8a, Woman-owned Small Business Or Service-disabled Veteran Owned Business And You Are Interested In This Project Please Respond Appropriately. this Design/bid/build Construction Contract Will Consist Of A Facilities Sustainment, Restoration, And Modernization (fsrm) Funded Renovation Project And An Unspecified Minor Military Construction (ummc) Funded Addition Project To B1232 At Beale Air Force Base, Ca. Project Entails Renovation Of Roughly 1,961 Square Feet (sf) (182 Square Meters) Within B1232, Including Metal Stud And Gypsum Board Interior Walls, Interior Finishes, Heating, Ventilation, And Air Conditioning (hvac), And Electrical And Communications Systems. The Renovated Areas Will Provide Space For 940 Arw Aircrews, Which Include Kitchens, Restrooms, Administrative Space, And Dining/briefing Areas. This Project Includes All Mechanical, Electrical, Civil, And Structural Repairs For A Complete And Usable Facility. the Ummc Funded Addition To B1232 Includes Restrooms, Crew Quarters, And Services Rooms And Is Approximately 5,000 Sf. Project Will Consist Of Concrete Foundation And Floor Slab, Steel Frame, Standing Seam Metal Sloped Roof, Metal Stud Backup And Brick Veneer, Metal Stud And Gypsum Board Interior Walls, And Interior Finishes. An Associated Aircrew Vehicle Parking Area Will Also Be Constructed Adjacent To The Flightline And New Addition. Project To Include Utilities, Site Improvements, Communications Infrastructure, Signage, Lighting, And All Necessary Supporting Work For A Complete And Usable Facility. contract Duration Is Estimated At 440 Calendar Days. The Estimated Cost Range Is Between $5,000,000 And $10,000,000. Naics Code Is 236220. All Interested Small Businesses, Certified Hubzone, 8a, Woman-owned Small Businesses Or Service-disabled Veteran Owned Business Contractors Should Respond To This Survey By Email On 4 March 2024 By 2:00 Pm Eastern Time. responses Should Include: 1. Identification And Verification Of The Company’s Small Business Status. 2. Contractor’s Unique Identifier Number And Cage Code(s). 3. Documentation From The Firm’s Bonding Company Showing Current Single And Aggregate Performance And Payment Bond Limits. 4. Descriptions Of Experience – Interested Construction Firms Must Provide No More Than Three (3) Example Projects With Either Greater Than 95 Percent Completion Or Projects Completed In The Past Five (5) Years Where The Interested Firm Served As The Prime Contractor. Each Project Must Include The Name, Title, Project Role, E-mail Address, And Telephone Number Of At Least One Reference. References May Be Used To Verify Project Size, Scope, Dollar Value, Percentages, And Quality Of Performance. Example Projects Must Be Of Similar Size And Scope. projects Similar In Scope To This Project Include: new Construction And/or Renovation Of Barracks, Hotels, And/or Administrative Type Facilities. b. Projects Similar In Size To This Project Include: projects 3,000 Sf Or Greater. c. Based On The Information Above, For Each Project Submitted, Include: current Percentage Of Construction Complete And The Date When It Was Or Will Be Completed. scope Of The Project. size Of The Project. the Dollar Value Of The Construction Contract And Whether It Was Design-bid Build Or Design-build. the Percentage Of Work That Was Self-performed As Project And/or Construction Management Services Or Physical Construction Type Work. identify The Number Of Subcontractors By Construction Trade Utilized For Each Project. 5. Small Businesses Are Reminded Under Far 52.219-14, Limitations On Subcontracting; They Must Perform At Least 15% Of The Cost Of The Contract, Not Including The Cost Of Materials, With The Firm’s Own Employees For General Construction-type Procurement. Include The Percentage Of Work That Will Be Self-performed On This Project, And How It Will Be Accomplished. note: Total Submittal Package Shall Be No Longer Than 8 Pages. Please Only Include A Narrative Of The Requested Information; Additional Information Will Not Be Reviewed. email Responses To Charity Mansfield At Charity.a.mansfield@usace.army.mil. If You Have Questions, Please Contact Charity Mansfield At 502-315-6925 This Is Not A Request For Proposal And Does Not Constitute Any Commitment By The Government. Responses To This Sources Sought Notice Will Be Used By The Government To Make Appropriate Acquisition Decisions. All Interested Sources Must Respond To Future Solicitation Announcements Separately From Responses To This Market Survey.

Administration Portuaire De Montr Al Montreal Port Authority Tender

Canada
Closing Date25 Sep 2024
Tender AmountRefer Documents 
Details: The work includes, among other things: the replacement of the heating, ventilation and air conditioning (HVAC) system, as well as automatic fire extinguishers. It also provides for interventions in plumbing, fire protection, as well as architecture and electrical supply.

Ministry of the Economy, Finance and Industrial and Digital Sovereignty - Regional Directorate of Ile-de-France and the Paris department (75572 - Paris cedex 12) Tender

Civil And Construction...+1Others
France
Closing Date26 Mar 2024
Tender AmountRefer Documents 
Details: Energy Conservation Works on the Site Located at 6a Boulevard De Reims in Paris 17th. Improvement of Summer Comfort The call for tenders will be in three lots: - HVAC - Solar films - Fixed horizontal sunshades

Alpes Maritimes Chamber Of Agriculture Tender

France
Closing Date25 Jan 2024
Tender AmountRefer Documents 
Details: Development of an existing building-rehabilitation Nice Chamber of Agriculture, Rehabilitation work, Second work: Plastering, Insulation, Tiling, Interior joinery, Electricity, HVAC plumbing, Painting, Flooring, Locksmithing, Elevator, Green spaces.

FEDERAL EMERGENCY MANAGEMENT AGENCY USA Tender

Civil And Construction...+1Others
Corrigendum : Closing Date Modified
United States
Closing Date2 Apr 2024
Tender AmountRefer Documents 
Description: The Pre-solicitation Notice Associated With This Solicitation Was Posted On January 22, 2024. This Request Forproposal (rfp) Solicitation 70fa2024r00000001 Will Only Be Available On The Government Point Of Entry (gpe) Web Page At Https://www.sam.gov/. this Solicitation Is For Facility Operations And Support Services (foss) For The Department Of Homeland Security(dhs) / Federal Emergency Management Agency (fema) / Center For Domestic Preparedness (cdp) Located Inanniston, Al. The Acquisition Operations Division/preparedness Section Intends To Award A Hybrid Firm-fixed-price Contract With Reimbursable Other Direct Costs (odcs) Under The Authority Of Far Part 15. the Intention Of This Requirement Is To Obtain Comprehensive Facilities Operations And Maintenance Services Tosupport The Dhs/fema/cdp And Its Facilities Located In Anniston, Alabama. Among These Facilities Is Thechemical, Ordnance, Biological And Radiological Training Facility (coratf), Which Has Unique Requirements Tomanage A Training Venue Where Chemical Agents (gb And Vx) And Biological Agents (ricin And Bacillus Anthracis)are Used In A Specialized Training Environment. This Will Require Contractor Response Capabilities On A 24-hour, 7-day-a-week Basis. The Contractor Shall Provide All Support Services As Identified In This Performance Workstatement (pws). The Objective Of This Procurement Is To Obtain Reliable, Efficient, And Effective Services By Applying A Sound Management And Technical Approach That Will Provide The Best Value And Meet The Objectives Shown. the Primary Functions To Be Performed Are The Operation, Maintenance, Repair, And Minor Alteration Of The Physical Facilities, Janitorial, Housekeeping And Lodging (billeting) Support Services And Mail Center Operations For The Cdp. The Contractor Shall Provide The Required Project Management, Administrative Services, Associated Scheduled (e.g., Preventive/predictive) Maintenance, Unscheduled Work (service Orders), Refuse Disposal, Hazardous Waste Management, Recycling, And Other Services Described Herein. In Performing These Functions The Contractor Shall Provide All Parts, Labor, Supervision And Administration, Tools, Equipment, Vehicles, Fuels, Vehicle And Equipment Maintenance Required, Unless Specifically Identified As Government Furnished. Physical Facilities Include, But Are Not Limited To The Following: a. Electrical Systems And Equipment b. Mechanical, Plumbing, Building Automation System (bas) Where Applicable (where Bas/ Ecms Systems Areconnected To The Cdp Network, The Contractor's Employees Shall Obtain A Cdp Account To Access Systems) And Heating, Ventilation, And Air Conditioning (hvac) Systems And Equipment c. Fire Protection And Life Safety Systems d. All Control Systems That Are Within The Scope Of This Contract. All Building Automation Systems (bas), Public Address Systems, And Lighting Systems That Are Within The Scope Of This Contract e. Architectural And Structural Systems, Fixtures, And Equipment Within The Site f. Service Request Desk Operations As Identified In The Pws, To Include Record Keeping Using A Computerized Maintenance Management System (cmms) g. Maintenance Of Grounds Irrigation Systems h. Tools And Maintenance Equipment (including Testing Equipment) i. Vehicle Barrier Systems And Static And Dynamic Bollard Systems j. All Doors And Windows k. Autoclave System l. Storm Drainage Systems - Reduce Storm Water Pollution By Minimizing Discharges And Runoff To The Storm Sewer System And Environment m. Facility Roofing Systems n. The U.s. Flag Pole, Lighting And Pulley System(s) o. All Site Drainage Systems p. Lightning Protection System q. Updates Of Software/firmware To Latest Revision And Update Software Licenses For Bas r. Water Storage System And Treatment (including Water Tower) s. Contaminated Waste Disposal, To Include Hazardous Waste t. Compressed Gases u. Air Filtration System (filter Banks) v. Safety Operations w. Package Boilers x. Civil Features y. Security Systems (excluding C-cure) z. Closed Circuit Television Systems And Monitors (cobratf) aa. Calibration Standards And Equipment Systems the Performance Work Statement (pws) Is Intended To Be Performance Oriented. However, Due To The Hazards That Could Be Encountered In Preparation For And During The Conduct Of Chemical And Biological Agent Training, Some Tasksare Specific And Must Be Executed Exactly As Required In Applicable Procedures. Any Proposing Offeror Is Invited And Encouraged To Provide A Technical Solution Which Identifies A More Performance-oriented Approach. There Are 35 Attachments With This Solicitation As Outlined In Section J Of The Solicitation. please Ensure To Review The Entire Solicitation And Provide All Appropriate Responses And Documentation Asrequired. With The Submission Of A Proposal Package As Outlined In Section L, Please Remember To Complete Allrequired Documents Within The Solicitation Packet, Including But Limited To: Sf 33, Of336, And Section K"representations, Certifications And Other Statements Of Bidders", If Applicable. this Competitive Acquisition Is Limited To Eligible Historically Underutilized Business Zones (hubzone) Concerns Only. Eligible Offerors Shall Be A Hubzone Concern In Accordance With Small Business Administration (sba) Requirements To Participate In This Competitive Acquisition. A Hybrid Firm-fixed-price Contract With Reimbursable Other Direct Costs (odc’s) Award Is Anticipated. Award Shall Be Based On Best Value To The Government Using Trade-offs On Price And Non-price Factors. The Period Of Performance Will Be One (1) Month Of Transition Followed By 11 Months Of Services For The Base Period Of Performance. The Contract Will Include Four (4), 12-month Options. The Anticipated Contract Performance Start Date Is July 1, 2024. Any Responsible Hubzone Concern May Submit A Proposal That Will Be Considered By The Government. the Naics Code Is 561210. The Small Business Size Standard For This Naics Is $47.0 Million. the Incumbent Contractor For This Requirement Is Hme, Inc., Under Contract Number 70fa2019c0008. Sources Sought Notice 70fa2023i00000007 Was Previously Issued For This Requirement. all Questions Shall Be Submitted No Later Than March 5, 2024, By Email To Gary Topper, Contracting Officer, At Email Address: Gary.topper@fema.dhs.gov And Justin Burger, Contract Specialist, At E-mail Address: Justin.burger@fema.dhs.gov. No Phone Calls Accepted. a Site Visit Is Scheduled For Tuesday, February 27, 2024, 8:00 Am (central Time), Center For Domestic Preparedness, 61responder Drive, Building 61, Room 2001, Ft. Mcclellan, Anniston, Al 36205. No More Than Three (3) Representatives Perpotential Offeror Will Be Admitted To The Site Visit. If You Plan To Attend, There Are Two (2) Separate Steps To The Process: step 1: It Is Required That You Email Your Company Name And List All Persons Who Will Be Attending To Gary.topper@fema.dhs.gov And Justin.burger@fema.dhs.gov. step 2: In Addition, It Is Also Required That You Submit Your Company Name, The Full Names Of All Persons Who Will Attend The Site Visit, Their Social Security Number, And Date Of Birth. This Information Shall Be Provided For All Site Visit Attendees So That A Criminal History Check May Be Performed. This Information Shall Be Emailed Only To The Cdp Security Office At Fema-cdp-security@fema.dhs.gov In A Password Protected Email, With A Separate Email Sent Containing The Password. Anyone Found To Have Disqualifying Information In Their Criminal History Will Not Be Permitted Access To Cdp Facilities. All Site Visit Information Shall Be Submitted No Later Than February 21, 2024, 4:00 Pm (central Time). There Will Be No Exceptions To This Deadline. Site Visit Attendees Without Prior Security Clearance Will Not Be Admitted Into The Cdp Facilities. note: Only One Site Visit Will Be Conducted. No Questions Will Be Entertained During The Site Visit. Any Questions Shall Be Submitted Via Email To The Contracting Officer And Contract Specialist Shown Above In Section L.3.d.1. With The Solicitation Number Referenced. No Other Site Visit Will Be Provided. proposals Are Due No Later Than 4:00 Pm (eastern), April 2, 2024. See Solicitation For Full Proposal Instructions.

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

United States
Closing Date6 Aug 2024
Tender AmountRefer Documents 
Description: Department Of Veterans Affairs network Contracting Office (nco) 16 request For Information (rfi) disclaimer: This Is A Sources Sought Notice Only. This Synopsis Is Not A Request For Quote, Proposal, Or Bid. This Notice Is Not A Solicitation As Defined By Far 2.101, Therefore It Shall Not Be Construed As A Commitment By The Government To Enter Into A Contract, Nor Does It Restrict The Government To An Acquisition Approach. All Information Contained In This Request For Information (rfi) Is Preliminary As Well As Subject To Amendment And Is In No Way Binding On The Government. Information Submitted In Response To This Notice Is Voluntary; The Government Will Not Pay For Information Requested Nor Will It Compensate Any Respondent For Any Cost Incurred In Developing Information Provided To The Government. The Government Is Requesting That Restrictive Or Proprietary Markings Not Be Used In Response To This Notice. If A Solicitation Is Released, It Will Be Synopsized In The Federal Contract Opportunities Website Or Gsa. It Is The Responsibility Of The Interested Parties To Monitor These Sites For Additional Information Pertaining To This Rfi. 1. Title: __ Mobile Ct Rental ___________________________________ 2. Purpose: The Purpose Of This Rfi Is To Identify Potential Sources Which Will Aid In Defining The Procurement Strategy (e.g., Set-aside, Sole Source, Unrestricted) For A Solicitation The Va Intends On Issuing Shortly For The Following: services Needed Under This Effort Are Described Below: the Contractor To Provide All Equipment, Tools, Materials, Labor, Transportation, Site Construction (to Include Utility Hook-ups (power, Data, Telephone), Equipment Training, On-site Installation, And Anything Else Necessary To Provide For An Equipment Lease For Fully Functioning/fully Operable Canon Ct Scanner And Mobile Trailer (or Equal) For The Gene Taylor Community Based Outpatient Clinic (va) At 1800 W. Republic St, Springfield, Mo 65807. The Vendor Is Responsible For Transporting The Unit To And From The Location. The Contractor Shall Be Tjc (the Joint Commission) Accredited And/or Shall Follow Established Tjc Guidelines, As They Pertain To The Mobile Ct Operations. The Period Of Performance Will Be For A One-month Base Period And Four (4) 1-month Option Periods. The Contractor Must Have The Capability Of Providing A Mobile Ct Unit To Be Onsite 7 Days Per Week For At Least The Base Period With Four (4) 1-month Option Periods Of Service. System/equipment Shall Be Fully Capable And Able To Transfer Image And Data To Multiple Modalities Including Va Pacs, Vista Imaging, Printers, And Hospital Ris System (full Dicom Communication). Each Location Shall Have Different Ip Addresses, Subnet Masks, And Vpns. Communication Between Ct And Radiology Services Pacs: The Contractor Shall Ensure That A Convenient And Robust Means Of Dicom Transfer Of Ct Studies To The Va Radiology Service Pacs Is Operational. The Contractor Shall Obtain And Provide To The Va Any Technology Necessary To Ensure That Ct Studies Can Be Conveniently Read On The Existing Va Pacs Display Technology. Any Peripherals That The Va Does Not Have But That Is Needed To Ensure Convenient And Timely Display Of Ct Studies In The Va Radiology Service Shall Be Obtained By The Contractor, Be Installed, And Be Retained By The Va So That At Future Dates The Archived Studies Can Be Reviewed. Each Ct Study Will Be Transferred To The Va Pacs Immediately Following The Acquisition Of The Study So That It Can, If Necessary, Be Reviewed Before The Patient Leaves The Ct Trailer. The Contractor Shall Have The Ct Trailer And Equipment In-place And Fully Operational On October 1, 2024. the Mobile Ct Equipment Shall Be Equal To Or Better Than The Description Of A Canon Aquilion Lightning 80 Row Ct Scanner. 3.1. Minimum Requirements For This System Are: 3.1.1. 80 Row, 4cm Detector That Emables 0.5mm Isotropic Imaging. 3.1.2. Purevision Optics To Support Dose Reduction And Improve Low Contrast Detectability. 3.1.3. 78 Cm Central Bore With A 116 Cm Flared Rear Gantry Design. 3.1.4. Weight Capacity Of Over 550 Lbs. 3.1.5. Scannable Range Of 2000mm To Accommodate Taller Patients. 3.1.6. Adjustable Table That Lowers To 13 Inches From The Floor For Patient Safety And Management. 3.1.7. Fda Cleared Single Energy Metal Artifact Reduction Software. 3.1.8. Automatic Couch Height Positioning Compensation To Correct Positioning Errors And Ensure Accurate Exposure Dose. 3.1.9. Additional Ct Trailer And System Requirements: 3.1.9.1. Bracco Empower Power Injector 3.1.9.2. Cd Burner 3.1.9.3. Full Compatibility With Hospital Pacs System 3.1.9.4. Dicom 3.0 3.1.9.5. Patient Intercom System 3.1.9.6. Safety And Warning Systems Visual And Audible Alarms 3.1.9.7. Smoke Detectors, Fire Extinguishers 3.1.9.8. Emergency Lighting Battery 3.1.9.9. Phone And Data Ports 3.1.9.10. 480v 50 Power Cable 3.1.9.11. Hydraulic Patient Lift, Stairs And Railings 3.1.9.12. Hvac System To Maintain Trailer Environmental Systems 3.1.9.13. Operators And Technical Support Manuals 3.1.9.14. Full System Service (monday Friday After Normal Duty Hours Local Time Excluding Federal Holidays) 3.1.9.15. Regular Scheduled Maintenance To Be Performed After Hours 3.1.9.16. 24 Hour Telephone Technical Support Toll Free Line, Response Within 1 Hour. the Anticipated Small Business Administration (sba) Size Standard For The North American Industry Classification System (naics) Code _ 532490_ Is __$40m__. 3. Responses Requested: The Following Questions Must Be Answered In Response To This Rfi. Answers That Are Not Provided Shall Be Considered Non-responsive To The Rfi: vendor Must Attach Documentation Of This To Be Viewed By The Government To Be Considered As Part Of The Market Research And Responsiveness To This Sources Sought Notice a. Name Of Potential Contractor That Possess The Capability To Fulfill This Requirement. Contractors Shall Also Provide The Following: point(s) Of Contact Name: _______________________________________________ Address: ___________________________________________________ Telephone Number: ___________________________________________ Email Address: _______________________________________________ company's Business Size: ________________________________________________ data Universal Numbering System (duns) #: _______________________________ b. Is Your Company Considered A Small Business Concern, Sb, Sdvosb, Vosb, Hubzone, Or 8a Concern, With The Requisite ___ 532490______ Naics Code? please Provide Proof Of Qualifications. C. Is Your Company Available Under Any Government Wide Agency Contract (gwac), General Services Administration (gsa) Schedule, Indefinite Delivery Indefinite Quantity (idiq), And/or Blanket Purchase Agreement (bpa)? If So, Please Identify The Contract Number For The Government To Review As Part Of This Market Research. 4. Opportunity/market Pricing: The Medvamc Is Seeking Information From Potential Vendors On Their Ability To Provide The Required Service. This Is A Sources Sought Request For Information (rfi) Only. Small Business Concerns Are Encouraged To Provide Responses To This Rfi In Order To Assist The Medvamc In Determining Potential Levels Of Competition And General Market Pricing Available In The Industry. Therefore, Vendors Are Requested To Submit Estimated Market Research Pricing Along With Their Responses To The Above. The Estimated Pricing Will Be Considered When Determining The Procurement Strategy For The Forthcoming Solicitation. 5. Instructions And Response Guidelines: Questions Regarding This Rfi Shall Be Submitted No Later Than 3:00pm (cst), August 6, 2024, Via Email To Lakeisha.white@va.gov. rfi Responses Are Due By 3:00pm (cst), Tuesday, August 6, 2024; Size Is Limited To 8.5 X 11 Inches, 12-point Font, With 1-inch Margins In Microsoft Word Format Via Email To Lakeisha.white@va.gov The Subject Line Shall Read: Mobile Ct Sources Sought. No Solicitation Exists At This Time. There Is No Page Limitation On Subparagraphs 3(a) - 3(f). please Provide The Information You Deem Relevant In Order To Respond To The Specific Inquiries Of The Rfi. Information Provided Will Be Used Solely By Medvamc As Market Research And Will Not Be Released Outside Of The Medvamc Purchasing And Contract Team. 7. Contact Information: lakeisha White lakeisha.white@va.gov your Response To This Notice Is Greatly Appreciated!

DEPT OF THE ARMY USA Tender

Other Consultancy Services...+1Consultancy Services
United States
Closing Date26 Mar 2024
Tender AmountRefer Documents 
Details: A Market Survey Is Being Conducted To Determine If There Are A Reasonable Number Of Interested Small Business Concerns To Set This Future Project Aside For Them. If Your Firm Is A Small Business, Certified Hubzone, 8a, Woman-owned Small Business Or Service-disabled Veteran Owned Business And You Are Interested In This Project Please Respond Appropriately. project Location: Niagara Falls Air Reserve Station, Ny project Description: Design/bid/build Contract To Include Construction Of A 2,500 Sf (232.3 Sm) Boom Operator Weapons System Trainer (bowst) Addition To Building 321 And Renovations Of Building 321 To Meet Facility Design Requirements For The Officer Flight Trainer (oft) Simulator. The Installation Of The Bowst And Oft Will Be By The Government And Not Part Of This Project. construction For The Addition Is To Comply With Bowst Manufacturer Requirements To Include Minimum Bowst High Bay Size Of 21’ H, 33’x34’; Insulated Overhead Door Access, Three Briefing Rooms, Parts Storage Room, Computer Room With Raised Flooring, And Mechanical/electrical Room. Facility To Include Five-foot-thick Reinforced Concrete Foundation And Floor Slabs, Steel Framing And Trusses, Masonry Exterior Walls, Standing Seam Metal Roofing System, Hvac, Electrical, Lighting, And Fire Systems. Computer Room Flooring Rated For Minimum 1,000-pound Rolling And 250-pound Concentrated Loading. Interior And Exterior Communications Infrastructure Is Included And Designed For Peak Use. Provide All Supporting Utilities, Pavements, And Landscaping Required For A Complete And Usable Facility. Exterior Finishes To Match Or Compliment Installation Architectural Standards. Include Space For Mechanical/electrical Equipment, Egress, And Personnel Circulation. Facility Layout To Meet Authorized Functional And Operational Mission Needs Of The Assigned Unit And Bowst. The Site Will Include All Utility Connections And Paved Maintenance/vehicle Access Route To High Bay. low Levels Of Pfos/pfoa Have Been Detected In The Soil And Groundwater Near The Bowst Site. Management, Testing, And Disposal Of Soil/groundwater To Comply With State And Federal Regulations For Pfos/pfoa Contamination Will Be Required As Part Of This Project. construction For The Renovation Is For The Simulator Space To Make It Secure And Compliant With Open Storage Requirements So The Sims Can Be On The Maf Dmo Dtcn Secure Network 24/7. Modify Interior Partitions And Doorways To Support Adequate Briefing Room Spaces Impacted By Bowst Addition And To Use Dedicated Computer Room Space More Efficiently. Modify Room 108a To Provide Environmental Controls And Adequately Sized Door Opening So Hpu And Mcc Fit. Provide Additional Restroom Capacity Within Existing Building Shell To Accommodate Increased Building Occupancy. Facility Layout To Meet Authorized Functional And Operational Mission Needs. Install 2-ton Overhead Crane In The High Bay. Install A New Drawbridge Tower And Stair Assembly. Install Chilled Water Supply For Cooling. Facility To Include Properly Located And Sized Hvac, Electrical, Lighting, And Fire Suppression Systems. Install Raised Pad For Mcc In Hydraulic Room. A New Exterior Pad Is Required For Ahu Cockpit Condenser. Replace Existing 6” Thick Permeable Concrete Pavement With Salt Resistant 6” Concrete Pavement. this Project To Comply With Dod Antiterrorism/force Protection Requirements Per Ufc 4-010-01. Facilities Will Be Designed As Permanent Construction In Accordance With The Department Of Defense Unified Facilities Criteria 1-200-01. Sustainable Principles, To Include Life Cycle Cost-effectiveness Practices, Will Be Integrated Into The Design, Development, And Construction Of The Project In Accordance With Ufc 1-200-02. contract Duration Is Estimated At 560 Calendar Days. The Estimated Cost Range Is Between $5,000,000 And $10,000,000. Naics Code Is 236220. All Interested Small Businesses, Certified Hubzone, 8a, Woman-owned Small Business Or Service-disabled Veteran Owned Business Contractors Should Respond To This Survey Via Email By Wednesday, March 26, 2024 By 3:00 Pm Eastern Standard Time. responses Should Include: identification And Verification Of The Company’s Small Business Status. contractor’s Unique Entity Identifier (uei). documentation From The Firm’s Bonding Company Showing Current Single And Aggregate Performance And Payment Bond Limits. description Of Experience – Provide Descriptions Your Firm’s Past Experience On Up To Three (3) Projects With Greater Than 95% Construction Complete, Or Those Projects Completed Within The Last Five Years Which Are Similar To This Project In Size, And Scope. Provide Documentation Demonstrating Experience For Construction Of Similar Type Buildings And Managing Multiple Sub-contractors. Demonstrate Experience Including Self-performing 15% Of The Construction. Provide Documentation Demonstrating Experience For Projects Of Similar Type Projects. Each Project Must Include The Name, Title, Project Role, E-mail Address, And Telephone Number Of At Least One Reference. References May Be Used To Verify Project Size, Scope, Dollar Value, Percentages And Quality Of Performance. a) Projects Similar In Scope To This Project Include: New Construction And/or Renovation Of Facilities For Simulators Or Secure Areas, Industrial Facilities, Hangars, Vehicle Maintenance Shops, And Warehouses. Construction Of Pre-engineered Buildings Will Not Be Considered Similar. b) Projects Similar In Size To This Project Include: New Construction And/or Renovation Of A Single Building Having A Minimum Of 1,500 Sf. c) Based On Definitions Above, For Each Project Submitted Include: current Percentage Of Construction Complete And The Date When It Was Or Will Be Completed. size Of The Project scope Of The Project the Dollar Value Of The Construction Contract the Percentage Of Work That Was Self-performed As Project And/or Construction Management Services Or Physical Construction Type Work. whether The Project Was Design Build Or Design/bid/build whether The Project Was Renovation Or New Construction provide At Least One Reference Point Of Contact (poc) 5. Small Businesses Are Reminded Under Far 52.219-14, Limitations On Subcontracting; They Must Perform At Least 15% Of The Cost Of The Contract, Not Including The Cost Of Materials, With The Firm’s Own Employees For General Construction-type Procurement. Include The Percentage Of Work That Will Be Self-performed On This Project, And How It Will Be Accomplished. note: Total Submittal Package Shall Be No Longer Than 10 Pages. Please Only Include A Narrative Of The Requested Information; Additional Information Will Not Be Reviewed. email Responses And Any Questions To Adam Brooks At Adam.m.brooks@usace.army.mil. This Is Not A Request For Proposal And Does Not Constitute Any Commitment By The Government. Responses To This Sources Sought Notice Will Be Used By The Government To Make Appropriate Acquisition Decisions. All Interested Sources Must Respond To Future Solicitation Announcements Separately For Responses To This Market Survey. notice: The Following Information Is Provided For Situational Awareness And Is Not Required To Respond To This Sources Sought. all Contractors Must Be Registered In The System For Award Management (www.sam.gov) Prior To Award Of A Contract. All Proposed Contractors Are Highly Encouraged To Review Far Clause 52.232-33 Payments By Electronic Funds Transfer – System For Award Management, Which Indicates “all Payments By The Government Under This Contract Shall Be Made By Electronic Funds Transfer (eft).” Those Not Currently Registered Can Obtain Registration By Going To The Website Http://www.sam.gov. The Process Can Usually Be Completed From 24 To 48 Hours After Submission. Contractors Will Need To Obtain A Unique Entity Identifier (formerly Duns Number) For Processing Their Registration. If You Do Not Already Have A Unique Entity Identifier, One Can Be Obtained From Http://www.sam.gov. Refer To Www.sam.gov For Information Formerly Found In Ccr, Epls, Orca And Fedreg. please Begin The Registration Process Immediately In Order To Avoid Delay Of The Contract Award Should Your Firm Be Selected. alert: You Must Submit A Notarized Letter Appointing The Authorized Entity Administrator Before Your Registration Will Be Activated. This Requirement Now Applies To Both New And Existing Entities. Effective 29 April 2018, The Notarized Letter Process Is Now Mandatory On All Current Registrants At Sam Who Have A Requirement To Update Data On Their Sam Record. The Notarized Letter Is Mandatory And Is Required Before The Gsa Federal Service Desk (fsd) Will Activate The Entity's Registration. effective 29 June 2018, Vendors Creating Or Updating Their Registration Can Have Their Registration Activated Prior To The Approval Of The Required Notarized Letter. However, The Signed Copy Of The Notarized Letter Must Be Sent To The Gsa Federal Service Desk (fsd) Within 30 Days Of Activation Or The Vendor Risks No Longer Being Active In Sam. vendors Can Check Whether An Account Is Active By Performing A Query By Their Cage Or Unique Entity Identifier (known As Duns). The New Registration Process May Now Take Several Weeks, So Vendors Are Highly Encouraged To Begin Registering As Soon As Possible To Avoid Any Possible Delays In Future Contract Awards. Remember, There Is No Cost To Use Sam. to Find Out Additional Information About The Changes Of The Sam Registration Process, Contractors Should Visit The Frequently Asked Questions (faq) Link Located At The Top Of The Sam Homepage (www.sam.gov).

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

Others
United States
Closing Date22 Oct 2024
Tender AmountRefer Documents 
Description: Department Of Veterans Affairs network Contracting Office (nco) 16 request For Information (rfi) disclaimer: This Is A Sources Sought Notice Only. This Synopsis Is Not A Request For Quote, Proposal, Or Bid. This Notice Is Not A Solicitation As Defined By Far 2.101, Therefore It Shall Not Be Construed As A Commitment By The Government To Enter Into A Contract, Nor Does It Restrict The Government To An Acquisition Approach. All Information Contained In This Request For Information (rfi) Is Preliminary As Well As Subject To Amendment And Is In No Way Binding On The Government. Information Submitted In Response To This Notice Is Voluntary; The Government Will Not Pay For Information Requested Nor Will It Compensate Any Respondent For Any Cost Incurred In Developing Information Provided To The Government. The Government Is Requesting That Restrictive Or Proprietary Markings Not Be Used In Response To This Notice. If A Solicitation Is Released, It Will Be Synopsized In The Federal Contract Opportunities Website Or Gsa. It Is The Responsibility Of The Interested Parties To Monitor These Sites For Additional Information Pertaining To This Rfi 1. Title: ____exhaust Installation_____ ______________________________________ 2. Purpose: The Purpose Of This Rfi Is To Identify Potential Sources Which Will Aid In Defining The Procurement Strategy (e.g., Set-aside, Sole Source, Unrestricted) For A Solicitation The Va Intends On Issuing Shortly For The Following: services Needed Under This Effort Are Described Below: provide The Equipment And Qualified Technicians To Core Drill Holes Sized For The Installation Of A Round 8 , 24 Guage Steel Hvac Duct From L232-21 Elevator Mechanical Room Located In The Lower Lever Through Floors 1, 2, And 3. Cut A Hole In The Roof Sized Per The Exhaust Fan Manufactures Specifications For The Installation Of The Exhaust Fan And Curb. core Drilling And Cutting Operations Shall Be Performed During Non-business Hours To Ensure The Least Interruption To Patient Services. The Contractor Shall Schedule Core Drilling, And Cutting Operations Times With Cor. install An 8 Round, 24 Guage, Galvanized Steel Exhaust Duct In Accordance With The International Mechanical Code From L232-21 Mechanical Room To The Roof. See Attachments A, B, C, And D For Routing. The Duct Is For Non-hazardous Exhaust. 1. Install Fire Dampers In The Duct At The 1st, 2nd, And 3rd Floor Penetration. An Access Cover Shall Be Installed In The Duct At Each Fire Damper To Provide Easy Access For Fire Damper Inspection And Service. 2. Seal Floor Penetrations With Code Approved Fire Rated Sealant Or Similar Code Acceptable Product. 3. Install A Motorized Backdraft Damper Below The Exhaust Fan. Contractor Shall Size The Damper To Be Compatible With Both The Fan And Duct Specified In The Sow. install An Exhaust Fan, Cook Model 120c17d Or Equal Manufactured At An Iso 9001 Certified Facility, Listed By Underwriters Laboratories (ul 705), And Bear The Amca Certified Ratings Seal For Sound And Air Performance. With The Following Salient Characteristics: 1. Minimum 16-gauge Marine Alloy Spun Aluminum. a) Base Shall Have Continuously Welded Curb Cap Corners. b) Discharge Baffle Shall Have A Rolled Bead. c) Centrifugal Type Wheel With Non-overloading, Backward-inclined Blades. d) Tapered Inlet Shroud. 2. 1/3 Horsepower, 115v, 1725 Rpm, Single Phase Motor. a) Integral Conduit Chase Shall Be Provided Through The Curb Cap And Into The Motor Compartment To Facilitate Wiring Connections. b) The Motor Shall Be Enclosed In A Weather-tight Compartment Separated From The Exhaust Airstream. c) The Motor Shall Be Direct Drive. 3. Fan Curve Characteristics: 4. Bear An Engraved Aluminum Nameplate With The Following Information: a) Tag Name Shall Be Listed As L232-21 Elev Mech Room . b) Design Cfm. c) Design Static Pressure. d) Voltage. e) Rpm. f) Phase. 5. Downblast Centrifugal Exhaust Ventilator. 6. Bolted And Welded Construction Utilizing Corrosion Resistant Fasteners. 7. Roof Mounted. a) Mounted On A Contractor Supplied Curb To Match Existing Curbs On Building 21. (1) Contractor Shall Modify The Roofing To Include Cutting The Decking, Replacing The Roof Insulation And Membrane As Required For Curb And Fan Installation With Materials To Match Existing. (2) Contractor Shall Leak Test The Roof And Fan To Ensure A Watertight Seal. 8. Install A Disconnect Switch Adjacent To The Fan For Servicing In Accordance With The National Electrical Code. 9. Install The Complete Electrical Service From The Most Convenient Electrical Room To The Exhaust Fan Including But Not Limited To The Circuit Breaker, Wire, Conduit, Fittings, And Fasteners Sized And Configured For The Exhaust Fan Electrical Requirements. a) Contractor Is Responsible To Size The Breaker, Conductors, Conduit, And Fittings Per The National Electrical Code And The Fan Manufactures Requirements. the Anticipated Small Business Administration (sba) Size Standard For The North American Industry Classification System (naics) Code _ 238220_______ Is _$19.0 M_____ . 3. Responses Requested: The Following Questions Must Be Answered In Response To This Rfi. Answers That Are Not Provided Shall Be Considered Non-responsive To The Rfi: a. Where Are The Requested Items/equipment Manufactured? vendor Must Attach Documentation Of This Information To Be Viewed By The Government To Be Considered As Part Of The Market Research And Responsiveness To This Sources Sought Notice b. Are The Requested Items/equipment Manufactured By A Small Or Large Business? Is The Potential Vendor In Compliance With The Non-manufacturer Rule (nmr)? vendor Must Attach Documentation Of This To Be Viewed By The Government To Be Considered As Part Of The Market Research And Responsiveness To This Sources Sought Notice c. Is The Vendor An Authorized Distributor With Access To Original Equipment Manufacturer (oem) Parts Which May Be Required In Performance Of This Requirement? the Va Does Not Accept Grey Market Items And Therefore The Vendor Must Attach Evidence Of This Access (authorized Distributor Letter) To Be Viewed By The Government To Be Considered As Part Of The Market Research And Responsiveness To This Sources Sought Notice. d. Name Of Potential Contractor That Possess The Capability To Fulfill This Requirement. Contractors Shall Also Provide The Following: point(s) Of Contact Name: _______________________________________________ Address: ___________________________________________________ Telephone Number: ___________________________________________ Email Address: _______________________________________________ company's Business Size: ________________________________________________ data Universal Numbering System (duns) #: _______________________________ e. Is Your Company Considered A Small Business Concern, Sb, Sdvosb, Vosb, Hubzone, Or 8a Concern, With The Requisite __________________ Naics Code? please Provide Proof Of Qualifications. F. Is Your Company Available Under Any Government Wide Agency Contract (gwac), General Services Administration (gsa) Schedule, Indefinite Delivery Indefinite Quantity (idiq), And/or Blanket Purchase Agreement (bpa)? If So, Please Identify The Contract Number For The Government To Review As Part Of This Market Research. 4. Opportunity/market Pricing: The Medvamc Is Seeking Information From Potential Vendors On Their Ability To Provide The Required Items/equipment. This Is A Sources Sought Request For Information (rfi) Only. Small Business Concerns Are Encouraged To Provide Responses To This Rfi In Order To Assist The Medvamc In Determining Potential Levels Of Competition And General Market Pricing Available In The Industry. Therefore, Vendors Are Requested To Submit Estimated Market Research Pricing Along With Their Responses To The Above. The Estimated Pricing Will Be Considered When Determining The Procurement Strategy For The Forthcoming Solicitation. 5. Instructions And Response Guidelines: Questions Regarding This Rfi Shall Be Submitted No Later Than 9:00 Am (cst), October 22, 2024 Via Email To Lakeisha.white@va.gov. rfi Responses Are Due By 9:00 Am (cst), Tuesday, October 22, 2024; Size Is Limited To 8.5 X 11 Inches, 12-point Font, With 1-inch Margins In Microsoft Word Format Via Email To Lakeisha.white@va.gov The Subject Line Shall Read: Medvamc Exhaust Installation. No Solicitation Exists At This Time. There Is No Page Limitation On Subparagraphs 3(a) - 3(f). please Provide The Information You Deem Relevant In Order To Respond To The Specific Inquiries Of The Rfi. Information Provided Will Be Used Solely By Medvamc As Market Research And Will Not Be Released Outside Of The Medvamc Purchasing And Contract Team. 7. Contact Information: lakeisha White lakeisha.white@va.gov your Response To This Notice Is Greatly Appreciated!

Health And Medico Social Establishments Tender

Civil And Construction...+1Civil Works Others
France
Closing Date31 Jul 2024
Tender AmountRefer Documents 
Details: Cecos Cryobiology Platform Extension Project at the Pellegrin Hospital Center Relaunch of Lots: 01 Demolition; Foundation ; Big work ; Vrd Green Space; Waterproofing 03 HVAC; Plumbing 04 Special Fluids

DEPT OF THE NAVY USA Tender

Aerospace and Defence
United States
Closing Date2 Mar 2024
Tender AmountRefer Documents 
Details: Naval Surface Warfare Center, Port Hueneme Division (nswc Phd) Is Conducting Market Research To Identify Qualified And Responsible Sources That May Be Interested In A Potential Future Procurement. This Sources Sought Notice Is Issued For Informational And Planning Purposes Only And Does Not Constitute An Invitation For Bid (ifb), Request For Quote (rfq), Or Request For Proposal (rfp). This Sources Sought Is Not A Commitment By The Government To Issue A Solicitation Or Award A Contract. In Accordance With Far 15.201(e), Responses To This Notice Are Not Offers And Cannot Be Accepted By The Government To Form A Binding Contract. The Government Will Not Reimburse Any Costs Associated With Response To This Notice. Information Submitted In Response To This Sources Sought Will Become The Property Of The United State Government. This Sources Sought Is Being Conducted To Identify Potential United States (us) Businesses That May Possess The Expertise, Capabilities, And Experience To Fulfill Requirements For The Innovation And Experimentation Modular Lab. If Pricing Information Is Provided Based Upon This Request, It Will Be Solely Used For Market Research And Will Not Be Used In Any Binding Form To The Government. The Government Reserves The Right To Follow Up On A One-on-one Basis With Respondents To Gain Additional Information Or Clarity About Information Submitted. a. Objective responses To This Sources Sought Notice Will Be Utilized To Determine If There Are Multiple Sources Capable Of Performing This Requirement. Responses Will Further Be Utilized To Determine If Small Business Set-aside Opportunities Exist. All Small Business Set-aside Categories Will Be Considered Under North American Industry Classification System (naics) Code 236220 Prefabricated Metal Building And Component Manufacturing Or 332311 Prefabricated Metal Building And Component Manufacturing. In Accordance With Far 52.219-14, Limitations On Subcontracting, Small Business Concerns Are Reminded That In Performance Of Contracts Awarded Under Small Business Set-aside Procedures, At Least 50% Of The Cost Of Contract Performance Incurred For Personnel Shall Be Expended For Employees Of The Concern. it Is Requested That All Interested Large And Small Business Concerns Including But Not Limited To Hubzone, 8(a) Small Disadvantaged Business (sdb), Women-owned Small Business (wosb) And Service Disabled Veteran Owned Small Businesses (sdvosb), Respond With A Capability Statement Of A Maximum Of 10 Pages That Demonstrates The Interested Party’s Capability To Perform The Requirements. Interested Small Business Concerns Must Identify Their Small Business Socio-economic Categories Under Both Naics Codes. complete Written Responses To This Sources Sought Should Include The Following Information: 1) Company Name; 2) Company Address; 3) Point Of Contact; 4) Telephone Number; 5) E-mail Address; 6) Company Cage Code; 7) Web Page Address; 8) Estimated Cost Order Of Magnitude (ex.5-10 Million, 10-15 Million, 15-20 Million, Etc.); 9) Business Socio-economic Category Under Both Naics Codes. questions Concerning This Sources Sought Shall Be Directed To: Jeremy Beckett Contract Specialist Jeremy.r.beckett.civ@us.navy.mil b. General Requirements this Sources Sought Outlines The Minimum Requirement For The Innovation And Experimentation Lab: approximately 13,350 Sf Modular Kit: This Space Will Be Home To 46 Different Rooms (conference Rooms, Office Spaces, Lab Space, Communication Rooms, And Common Areas). intelligence Community Directive (icd) 705 Spaces: Approximately 8,650 Sf Of The Modular Space Will Consist Of Icd-705 Spaces That Must Adhere To Security Requirements Set Forth Within The Icd-705. The Spaces Modular Panels Will Be True Floor To True Ceiling And Have An Rf Shielding Decibel (db) Rating Of -80 And A Sound Transmission Class (stc) Rating Of 50. We Understand That Lab Rating And Finished In-place Product Ratings Are Different, In This Case The Finished Product Rating Is Required To Be -80 For Rf And 50 For Stc. Rf & Sound Testing (astm) Will Be Required To Show Proof That The Desired Rating Was Reached For The Entirety Of The Space. Hvac Vents/ducting & Utilities Will Be Installed In A Way That Complies With Tempest Requirements (power Filters, Dielectric Breaks, Etc.) The Icd-705 Space Will Have A Fully Operational Intrusion Detection System (ids). The Ids System Will Be Required To Be Installed To Meet Underwriters Laboratories (ul) 2050 And Provide A Certification Stating Such. The Ids Will Have High Security Sensor (hss) Sensors On All Perimeter Doors Within This Facility, It Will Also Be Required To Have 360-degree Motion Sensors Within 3 Feet Of Any Entrance To The Space. The Ids Premise Control Unit (pcu) Will Be Housed Within Icd-705 Space (in Comm Room). Primary (main Entry) Doors To The Space Must Meet The -80 Db Rf Rating And Be Stc 50. Primary Doors Must Be Equipped With A Deadbolt Meeting Ff-l-2890, Have A Combination Lock Meeting Ff-l-2740 & Be Equipped With A By-pass Keyway. Emergency Egress Doors Must Meet The -80 Db Rf Rating And Be Stc 50. They Will Also Be Equipped Emergency Egress Device With A Deadbolt Configuration Meeting The Most Current Version Of Federal Specification Ffl-2890 For Exit Only Door Use. Emergency Exit Doors Must Also Have A 24/7 Locally Annunciated Alarm. No Exterior Hardware Is Authorized For Emergency Exit Doors. All Perimeter Doors (primary & Emergency) Must Be Equipped With Automatic Non-hold Door Closers Installed On The Inside Of The Door. Hinge Pins That Are Accessible Form Outside Must Be Equipped In A Way That Prevents Removal Of Door. All Internal Non-perimeter Doors Will Meet A Stc Rating Of 50. A Set Of Rolling (colored) Lights Will Be Installed Throughout This Space And Be Controlled From The Front Of The Space. open Secret Storage Spaces (oss): Approximately 2,750 Sf Of The Modular Space Will Consist Of Oss Spaces And Must Adhere To The Security Requirements Of The Secnav M-5510.36. This Space Is Not Required To Have An Rf Rating, But It Is Required To Be True Floor To True Ceiling And Be Built To Meet An Stc Rating Of 50. This Space Will Be Equipped With Its Own Ids System. The Ids System Will Be Installed In Accordance With The Above Stated Manual. Primary & Emergency Doors Will Have Level Ii Hss Installed On Them. There Will Be A Motion Sensor Installed Within 3 Feet Of The Primary Entry & Emergency Exit Doors. The Pcu Will Be Located Within The Oss Space (in Comm Room). A Set Of Rolling (colored) Lights Will Be Installed Throughout This Space And Be Controlled From The Front Of The Space. The Hvac And Power System Will Be Built To The Secnav M-5510.36 Specs For Classified Space. unclassified Common Spaces: Approximately 1,950 Sf Of The Modular Space Will Consist Of Unclassified Common Spaces Including A Common Area, Restroom Facilities, Kitchenette/breakroom, Electrical And Mechanical Rooms, & A Counterfeit Material Prevention Program (cmpp) Laboratory. These Spaces Do Not Need To Meet Any Stc Rating. entire Space: The Entire Space Will Have An Icd-705 Compliant Access Control System (acs) That Services All Spaces Within The Facility (unclassified Space Minus The Front Door Do Not Require Card Readers), The Brain Of This System Must Sit Within The Icd-705 Space. The Access Control Transmission Lines Must Be Protected By 128-bit Encryption/fips 140. All Card Readers That Are Not Within A Secure Area (icd-705 & Oss) Must Be Protected Using An Anti-tamper Device. This Automated System Must Incorporate Two Verification Methods (biometric, Badge, Personal Pin). The Facility Will Also Employ The Use Of A Closed-circuit Television (cctv) System With A Digital Video Recorder (dvr) That Has The Ability To Record And Store Data For 30 Days. The Systems Brain Will Be Protected And Housed Within The Icd-705 Space. All Transmission Lines External To The Icd-705 Space Shall Be Installed To Prevent Tampering. Cameras Should Be Placed On The Exterior Of The Facility Pointing At All Emergency Exits, The Main Entry To The Modular Facility, The Entry Door To The Oss Space And The Entry Door To The Icd-705 Space. The Dvr & Cctv System Needs To Be Able To Allow For The Customer To Customize What Feeds Are Being Shown On Individual On Monitors. Monitors That Display The Camera Feeds Will Be Placed Within Four Areas In The Icd-705 Space And One Area Within The Oss Space. the Modular Lab Will Be Designed To Be Installed Inside A Warehouse Facility At Naval Base Ventura County Located At Port Hueneme, California. The Modular Lab Installation Must Adhere To Federal, State And Local Laws Regarding Modular Spaces. c. Requested Information 1. Interested Parties Shall Respond By Specifying If They Have Current Commercial Products Available That Expressly Meet The Parameters Listed In Section B. Interested Parties May Include Item Brochure Information With Their Response. 2. Describe Capabilities And Experience In Manufacturing Modular Spaces With The Security Requirements Listed In Section B. 3. If Possible, Demonstrate Ability And Experience In The Manufacture Of The Same Or Similar Components, Which Are Currently Utilized In The Commercial Or Military Environment By Providing The Following Information On The Same Or Similar Type Modular Labs: A) Contract Number B) Procuring Agency C) Contract Value D) Number Of Assets Procured 4. Provide Separate Estimated Timelines For Proposal Development, Design, Fabrication/manufacturing, And Installation With Regard To The Requirements Of This Effort. 5. Provide Information And Capabilities Demonstrating Your Ability To Meet The Rf Shielding Db Rating Of -80 And A Stc Rating Of 50. 6. Provide Overall Feedback Regarding The Requirements To Include, But Not Limited To Potential Issues. d. Responses responses To This Sources Sought Are Due No Later Than 4:00 Pm Pacific Standard Time (pst) On Friday, 1 March 2024. All Responses Are To The Submitted Via Email To Gary Heagy, Contracting Officer At Gary.l.heagy.civ@us.navy.mil And Jeremy Beckett, Contract Specialist At Jeremy.r.beckett.civ@us.navy.mil.
7001-7010 of 7400 archived Tenders