Freeze Point Tenders
Freeze Point Tenders
Luonnonvarakeskus Tender
Others
Finland
Closing Date4 Nov 2024
Tender AmountRefer Documents
Details: Title: Automated Soil Gas Flux Chambers
description: Natural Resources Institute Finland (hereafter Referred To As "luke") Requests Your Tender For Automated Soil Gas Flux Systems With This Call For Tenders And Its Annexes. Luke Is Planning To Procure Two (2) Automated Soil Gas Flux Systems In 2024 To Ruukki Experimental Station (siikajoki, Finland), One System For Measurements Of Soil Gas Fluxes In High Vegetation And One System For Measurements Of Soil Gas Fluxes In Low Vegetation. This Procurement Consists Of Two Lots With Different Requirements. All Devices Will Be Used In Field Conditions In Finland Over Three Seasons (spring, Summer, Fall) For The Purposes Of Forest And Agricultural Studies. During Spring, Summer And Fall The Temperature May Drop Below Freezing Point. Therefore, The Chambers And Equipment Must Withstand Conditions Below 0°c. Devices/systems Will Be Used With Luke's Existing Trace Gas Analyzers, Specifically Licor Li-7810 And Li-7820 And Therefore The Systems Offered Must Be Compatible With Them. Devices Must Also Be Compatible With Other Analyzers With Or Without Modifications. The Call For Tenders And The Procurement Is Divided Into Two (2) Lots: Lot 1, High Vegetation Includes: A System Including 3 Opaque Chambers And 3 Transparent Chambers (the Chamber Or A Combination Of Offered Chambers Must Be Able To Measure Simultaneously Transparent And Opaque. If The Same Chamber Can Be Used For Opaque And Transparent Measurements, The Total Number Of Chambers To Be Included Is 3.) For A Measurement Set-up Capable To Measure In High Vegetation Up To 70 Cm, 1 Multiplexer, 1 Datalogger And Additional Hardware Required To Form A Ghg Measuring System With Analysers (analysers Not Included). Option 1: Lot 1 Includes An Option For Luke To Purchase 5 Pairs Of Opaque And Transparent Chambers (pair = 1 Opaque And 1 Transparent Chamber) Within The Next Four Years. Option 2: Lot 1 Includes An Option For Luke To Purchase 2 Additional Multiplexers Within The Next Four Years. Option 3: Lot 1 Also Includes An Option For Luke To Purchase An Off-grid Power Supply Capable To Power System Of Minimum Of 8 Chambers With Chamber Types Offered In Lot 1 In Addition To Two Trace Gas Analyzer (max Combined Power Draw 130 W, Steady State After Warm Up 44 W, Analyzers Accepts 10.5 To 33 Vdc) In Temperatures Ranging From -5 To 40 °c. The Tenderer Is Not Required To Offer This Option. Lot 2, Low Vegetation Includes: A System Including 4 Portable Opaque Chambers For A Measurement Set-up Capable To Measure With Vegetation Up To 30 Cm, 1 Multiplexer, 1 Datalogger, 1 Cellular Communication System Datalogger And Additional Hardware Required To Form Ghg Measuring System With Analysers (analysers Not Included). For Lot 2 There Also Needs To Be A Capability To Monitor And Configure The System Remotely Over Cellular Network. Option 1: Lot 2 Includes An Option For Luke To Purchase 10 Opaque Chambers Within The Next Four Years. Option 2: Lot 2 Includes An Option For Luke To Purchase 2 Additional Multiplexers Within The Next Four Years. Option 3: Lot 2 Includes An Option For Luke To Purchase 2 Dataloggers Within The Next Four Years. Option 4: Lot 2 Also Includes An Option For Luke To Purchase An Off-grid Power Supply Capable To Power Systems Offered In Lot 2 (+ 4 Additional Chambers) In Addition To Two Trace Gas Analyzer (max Combined Power Draw 130 W, Steady State After Warmup 44 W, Analyzers Accepts 10.5 To 33 Vdc) In Temperatures Ranging From -5 To 40 °c. The Tenderer In Not Required To Offer This Option. Tenderer Can Leave A Tender For One Or Both Of The Lots. The Supply Purchase Contract In Each Slot Will Be Made With One Supplier. The Subject Of The Procurement Is Described In More Detail In Procurement Object Criteria And Other Procurement Documents.
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Healthcare and Medicine
United States
Closing Date16 Feb 2024
Tender AmountRefer Documents
Details: This Is A Sources Sought Notice In Support Of The Syracuse Va Medical Center In Syracuse, Ny For Market Research Purposes Only To Determine The Availability Of Potential Businesses With Capabilities To Provide The Requirement Described Below. Potential Offerors Are Invited To Provide Feedback Via E-mail To Stephanie.decker2@va.gov. Responses Will Be Used To Determine The Appropriate Acquisition Strategy For A Potential Future Acquisition. All Responses Due By February 16, 2024 At 14:00 Edt. potential Contractors Shall Provide, At A Minimum, The Following Information:
1) Company Name, Address, And Point Of Contact, Phone Number, E-mail Address, And Duns. 2) Anticipated North American Industry Classification System (naics) Code Is 811310- Commercial And Industrial Machinery And Equipment (except Automotive And Electronic) Repair And Maintenance
. If You Believe A Different Naics Is More Appropriate, Please Indicate With Your Response. is Your Firm Eligible For Participation In One Of The Following Small Business Programs? If So, Please Indicate The Program. [ ] Yes [ ] No Small Business (sb) [ ] Yes [ ] No Hubzone [ ] Yes [ ] No Small Business 8(a) [ ] Yes [ ] No Small Disadvantaged Business (sdb) [ ] Yes [ ] No Women-owned (wo) Small Business
[ ] Yes [ ] No Service Disabled Veteran Owned Small Business (sdvosb)
[ ] Yes [ ] No Veteran Owned Small Business (vosb) [ ] Yes [ ] No Other (please Specify) 3) What Additional Information Would The Government Need To Provide For You To Be Able To Submit An Accurate And Complete Offer With Full Understanding Of The Requirements If We Post A Formal Solicitation? 4) Provide A Brief Capability Statement (max 2 Pages) With Enough Information To Determine If Your Company Can Meet The Requirement. The Capabilities Statement For This Sources Sought Is Not Expected To Be A Request For Quotations, Request For Proposals Or Invitation For Bids, Nor Does It Restrict The Government To An Ultimate Acquisition Approach, But Rather The Government Is Requesting A Short Statement Regarding The Company S Ability To Provide The Services Outlined Below. Any Commercial Brochures Or Currently Existing Marketing Material May Also Be Submitted With The Capabilities Statement. Submission Of Capabilities Statement Will Assist Our Office In Tailoring The Requirement To Be Consistent With Industry Standards. The Capabilities Will Be Evaluated Solely For The Purpose Of Determining To Set-aside For The Small Business (sb) Community Or To Conduct As An Unrestricted Procurement. Other Than Small Businesses May Respond To This Notice In The Event The Market Does Not Indicate Sb Interest. This Synopsis Is For Information And Planning Purposes Only And Is Not To Be Construed As A Commitment By The Government. The Government Will Not Pay For Information Solicited. Respondents Will Not Be Notified Of The Results Of The Evaluation. note: Do Not Include Proprietary, Classified, Confidential, Or Sensitive Information In Responses. not Responding To This Sources Sought Does Not Preclude Participation In Any Future Or Potential Solicitation, Or Request For Quotation. It Is The Intent Of The Va To Use The Information Gathered For Market Research Purposes Only. If A Formal Solicitation Is Released, It Will Be Posted Via The Contracting Opportunities Website Located At Sam.gov. description Of The Requirement:
preventative Maintenance (pm) To 3 1300 Hp Cummins Generator Units. The Procedures At A Min Shall Include The Following Information: Loto(lock Out Tag Out) Shall Be Performed To Standards. Fuel, Coolant, Oil, All 3 Fluids Sampling On All 3- Generators Units All 3 Generator Units Fluids, Filters & Materials Cost Check Lubricating Oil, Add As Needed After Test Run. Change Lubricating Oil And Oil Filter. Check Radiator /cooling Systems (radiator Cap, Water Pump, Coolant Hose /clamps). Add Coolant As Required. Perform Onsite Coolant Analysis-test Freeze Point Nitrate Levels, Corrosion Inhibitor Levels. Check Air Filters, Hoses, And Crankcase Breather. Change Air Filter As Needed. Check Fuel Lines /hoses For Leaks/pliability, Inspect Fuel Vents For Obstructions, Check /clean Fuel Sediment Bowl. Replace Fuel/ Water Separator (if Applicable). Check (and Notate For Diagnosis) Warning Light Illuminated, Gauges/ Instrumentation Function /faults. Check Fan Belts For Excessive Wear, Inspect /adjust Tension. Check Governor Belts For Excessive Wear, Adjust Tension If Needed (if Applicable) Check Battery Charger, Adjust If Necessary. Replace Spark Plugs, Set Points, Distributor Cap And Ignition Rotor (if Applicable) Check Battery Capacity, Clean Battery, And Apply Anti Corrosion Treatment And Safety Check. Perform Generator, Generator End, Ats & Component Functional And Safety Check. Test/run Generator -under Load When Possible (customer Authorization Required) Conduct Electrical Frequency Analysis And Adjust If Necessary. 1.2.1. The Contractor Shall Provide All Personnel, Materials, Tools, Labor, And Transportation Necessary To Complete The Work Identified In This Statement Of Work (sow). 1.2.2. Contractors Shall Include A Detailed Invoice Of All Work Completed Prior To Payments. 1.2.3. The Contractor Shall Correct/re-perform Any Discrepancies Or Integration Errors Found At No Additional Cost To The Government. 1.2.4. The Contractor Shall Be Responsible For Returning The Work Site To Its Original Condition At Completion Of The Installation, To Include Replacement Of Any Damaged Or Destroyed Equipment. 1.2.8 The Contractor Must Inform The Facility Security Office Prior To Any Work Being Performed If Work Will Prevent Normal Security Status At The Completion Of The Performance Day. 1.2.9 The Contractor Must Check In And Out Each Day With The On-site Contractor Officer Representative 852.212-72â Gray Market And Counterfeit Items.
gray Market And Counterfeit Items (mar 2020) (deviation)
(a) No Used, Refurbished, Or Remanufactured Supplies Or Equipment/parts Shall Be Provided. This Procurement Is For New Original Equipment Manufacturer (oem) Items Only. No Gray Market Items Shall Be Provided. Gray Market Items Are Oem Goods Intentionally Or Unintentionally Sold Outside An Authorized Sales Territory Or Sold By Non-authorized Dealers In An Authorized Sales Territory.
(b) No Counterfeit Supplies Or Equipment/parts Shall Be Provided. Counterfeit Items Include Unlawful Or Unauthorized Reproductions, Substitutions, Or Alterations That Have Been Mismarked, Misidentified, Or Otherwise Misrepresented To Be An Authentic, Unmodified Item From The Original Manufacturer, Or A Source With The Express Written Authority Of The Original Manufacturer Or Current Design Activity, Including An Authorized Aftermarket Manufacturer. Unlawful Or Unauthorized Substitutions Include Used Items Represented As New, Or The False Identification Of Grade, Serial Number, Lot Number, Date Code, Or Performance Characteristics.
(c) Vendor Shall Be An Oem, Authorized Dealer, Authorized Distributor Or Authorized Reseller For The Proposed Equipment/system, Verified By An Authorization Letter Or Other Documents From The Oem Or By An Intermediary Distributor Authorized By The Oem. All Software Licensing, Warranty And Service Associated With The Equipment/system Shall Be In Accordance With The Oem Terms And Conditions. If Your Firm Is Interested And Capable, Please Send The Capability Statement Outlined Above, And A Market Research Quote To Stephanie.decker2@va.gov By 14:00 Edt On February 16, 2024. No Phone Calls, Please. again, This Is Not A Request For Quote, And No Solicitation Is Available At This Time.
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY USA Tender
United States
Closing Date21 Aug 2024
Tender AmountRefer Documents
Details: Announcement Type: Special Notice
classification Code: 6640 announcement Number: Nb685010-24-02664 (noi)
subject: Notice Of Intent To Noncompetitively Acquire Potassium Heat Pipe Dual Furnaces the Nist Thermodynamic Metrology Group Maintains And Develops National Standards Of Temperature (in The Range 0.65 K To 2011 K), And Supports Calibration Of All Types Of Contact Thermometers Up To 2370 K. The Standard Platinum Resistance Thermometer Calibration Laboratory (sprtcl) Provides Critical National And International Stakeholders With Si Traceability To The Kelvin. Government, Military, Pharmaceutical, Aerospace, And High-level Industrial Calibration Laboratories Depend On The Low Uncertainties And Direct Si Traceability Provided By The Sprtcl. as Part Of The Realization Of The Its-90 Temperature Scale, The Zinc (zn) And Aluminum (al) Fixed Points Require High-temperature Heat Pipe Furnaces. In Order For Nist To Offer Services For The Calibration Of Standard Platinum Resistance Thermometers (sprt) At High Temperatures, Nist Requires High Performance Metrology Furnaces To Maintain Nist Specific Zn And Al Cells At Their Respective Freezing Points. Due To The Age And Unreliability Of The Current High Temperature Furnaces, Nist Must Procure Additional Furnaces Should Additional Hardware Failures Render The Current Furnaces Inoperable. The Replacement Furnaces Must Be Easily Integrated Into The Existing Measurement Service Infrastructure. It Is Important That The Furnaces Properly Accommodate Nist Fixed-point Cells To Optimize The Heat Exchange Between The Furnace And The Cells, Allowing For The Realization Of The Its-90 Temperature Scale With State-of-the-art Accuracy. this Notice Is Not A Request For A Quotation. A Solicitation Document Will Not Be Issued And Quotations Will Not Be Requested. this Acquisition Is Being Conducted Under The Authority Of Far 13.106-1(b) Via Far 13.106-1(b). The North American Industry Classification System (naics) Code For This Acquisition Is 334516, Analytical Laboratory Instrument Manufacturing. custom Designed Furnaces That Fit The Dimensions Provided By Nist For The High Temperature Fixed Point Cells. These Furnaces Need To Have Potassium Heat Pipes And A Dual Design With Independent Temperature-controlled Wells Allowing For Heating And Cooling Of The Sprt During Calibrations. Only Two Companies Manufacture Heat Pipe Furnaces. Isotech North America, Inc., Manufactures Potassium Heat Pipe Furnaces And Is Also Able To Customize Their Furnace Design To Accommodate Nist-manufactured Cells. technical Specifications: The Nist Thermodynamic Metrology Group Maintains And Develops National Standards Of Temperature (in The Range 0.65 K To 2011 K), And Supports Calibration Of All Types Of Contact Thermometers Up To 2370 K. As Part Of The Realization Of The Its-90 Temperature Scale, The Zinc (zn) And Aluminum (al) Fixed Points Require Heat Pipe Furnaces. In Order For Nist To Offer Services For The Calibration Of Standard Platinum Resistance Thermometers (sprt) At High Temperatures, New Furnaces Must Be Acquired Which Can Reach These Temperatures To Realize The Fixed Points Using The Nist Specific Zn And Al Cells. These Furnaces Should Also Be Capable Of Pre-heating And Cooling Sprts Before And After Calibrations At The In And Sn Fixed Points. It Is Important That The Furnaces Properly Accommodate Nist Fixed-point Cells To Optimize The Heat Exchange Between The Furnace And The Cells, Allowing For The Realization Of The Its-90 Temperature Scale With State-of-the-art Accuracy. The Nist Temperature And Humidity Group Requires Two (2) Custom Potassium Heat Pipe Furnaces With Heat Pipes With The Following Dimensions Specifications. 1. Custom Design To Accommodate Nist Specific Fixed-point Cells; 2. Heat Pipe Cavity Depth Must Be Deep Enough To Accommodate Nist Cells: 530 ±1.52 Mm; And 3. . Heat Pipe Cavity Diameter Between 53.20 Mm And 54.75 Mm. nist Conducted Market Research From In June 2024 By Internet Searches, Discussions With Sources, And A Sources Sought Posting. Sources Sought Nb685010-24-02664 Was Posted From August 2, 2024, To August 9, 2024 With No Responses. The Results Of That Market Research Revealed That Only Isotech North America, Inc., 158 Brentwood 4, Colchester, Vt 05446 United States, Uei: Mjv6cbau3n98 Appears To Be Capable Of Meeting Nist’s Requirements. however, Any Sources That Believe They Are Capable Of Meeting Nist’s Minimum Requirements Are Encouraged To Respond To This Notice By The Response Date To Provide The Following Information At A Minimum: Company Unique Entity Identifier Number In Https://sam.gov; Details About What Your Company Is Capable Of Providing That Meets Or Exceeds Nist’s Minimum Requirements; Whether Your Company Is An Authorized Reseller Of The Product Or Service Being Cited And Evidence Of Such Authorization; And Any Other Information That Can Help Nist Determine Whether This Requirement May Be Competitively Satisfied.
DEFENSE LOGISTICS AGENCY USA Tender
Electrical Goods and Equipments...+1Electrical and Electronics
United States
Closing Date25 Sep 2024
Tender AmountRefer Documents
Details: This Is A Combined Synopsis/solicitation For Commercial Items Prepared In Accordance With The Format In Subpart 12.6 And 13.5 Of The Federal Acquisition Regulations (far), As Supplemented With Additional Information Included In This Notice. This Announcement Constitutes The Only Solicitation; Quotations Are Being Requested And A Written Solicitation Will Not Be Issued. this Solicitation, Spe60524q0027, Is Issued As A Request For Quotation (rfq) For Commercial Items Using The Simplified Acquisition Procedures (sap) In Accordance With Far Parts 12 And 13. The Contract Resulting From This Procurement Will Be A Firm Fixed Price Contract. This Document And Incorporated Provisions And Clauses Are Those In Effect Through Federal Acquisition Circular 2024-06 Dated 29 August 2024. Dpas Rating For Potential Award Is Do. The Clauses And Provisions Referenced In This Solicitation May Be Reviewed/obtained In Full Text Form At: https://www.acquisition.gov/browse/index/far https://www.acq.osd.mil/dpap/dars/dfarspgi/current/ this Solicitation Is 100% Set-aside For Small Business Under Naics 334516 subject: Request For Quotation Spe60524q0027 dla Energy Has A Request For Quote (rfq) For A Requirement For The Items Listed Below. Award Will Be Made To The Lowest Priced, Responsible Offeror. Offerors Must Offer On All Line Items Within Each Pr Grouping To Be Considered For Award. Partial Offers Within Each Pr Grouping Will Not Be Considered. item Description: pr Group 01 clin 0001 location: Pt. Loma, California, Usa unit Price: __________ nomenclature: Emcee Model 1152 Precision Conductivity Meter unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D2624/d4308 accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Emcee, Model 1152 clin 0002 unit Price: _____________ nomenclature: Shipping For Clin 0001 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 02 clin 0001 location: Pt. Loma, Ca Usa unit Price: _________ nomenclature: Falex Ellipsometric Tube Reader (etr), F430 unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D3241 Thermal Oxidation Stability Of Aviation Turbine Fuels • Electrical Requirements: 120-220v, 50/60 Hz, Type B Plug • Accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. • All Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. • The Equipment Shall Include A One-year Warranty. • Shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Falex Ellipsometric Tube Reder (etr), F430 clin 0002 unit Price:___________ nomenclature: Shipping For Clin 0001 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 03 clin 0001 location: Pearl Harbor, Hi Usa unit Price: _________ nomenclature: Falex Ellipsometric Tube Reader (etr), F430 unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D3241 Thermal Oxidation Stability Of Aviation Turbine Fuels • Electrical Requirements: 120-220v, 50/60 Hz, Type B Plug • Accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. • All Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. • The Equipment Shall Include A One-year Warranty. • Shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Falex Ellipsometric Tube Reder (etr), F430 clin 0002 unit Price: _________ nomenclature: Shipping To Pearl Harbor, Hi Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Pearl Harbor Fuel Terminals Laboratory 300 Neches Street Building 1685 honolulu, Hawaii 96860 pr Group 04 clin 0001 location: Puget Sound, Wa Usa unit Price: _________ nomenclature: Falex Ellipsometric Tube Reader (etr), F430 unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D3241 Thermal Oxidation Stability Of Aviation Turbine Fuels • Electrical Requirements: 120-220v, 50/60 Hz, Type B Plug • Accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. • All Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. • The Equipment Shall Include A One-year Warranty. • Shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Falex Ellipsometric Tube Reder (etr), F430 clin 0002 unit Price: __________ nomenclature: Shipping For Clin 0001 To Puget Sound, Wa Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional Puget Sound manchester Fuel Department, Bldg. 194 7501 Beach Drive East port Orchard, Wa 98366 pr Group 05 clin 0001 location: Jacksonville, Fl Usa unit Price: ___________ nomenclature: Falex Thermal Oxidation Stability Tester, F400, 120v unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D3241 Thermal Oxidation Stability Of Aviation Turbine Fuels electrical Requirements: 120v, 50/60 Hz, Type B Plug accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Falex Thermal Oxidation Stability Tester, F400 clin 0002 unit Price: __________ nomenclature: Shipping For Clin 0002 To Jacksonville, Fl Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional Jacksonville fuel Department 8808 Somers Road S jacksonville, Fl 32226-2600 pr Group 06 clin 0001 location: Point Loma, Ca, Usa unit Price: __________ nomenclature: Falex Visual Tube Reader (vtr), F420 unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D3241 Thermal Oxidation Stability Of Aviation Turbine Fuels electrical Requirements: N/a accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Falex Visual Tube Reder (vtr), F420 clin 0002 unit Price: __________ nomenclature: Shipping For Clin 0003 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Adress To: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 07 clin 0001 location: Anchorage, Alaska, Ca unit Price: __________ nomenclature: Emcee Model 1140 Mk X Microseparometer (msep) unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D7224, Determining Water Separation Characteristics electrical Requirements: 120v, 50/60 Hz, Type B Plug accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Emcee, Model: 1140 Micro-separometer. clin 0002 unit Price: __________ nomenclature: Shipping description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Adress To: petroleum Laboratory jber, Ak 99505 pr Group 08 clin 0001 location: Jacksonville, Fl Usa unit Price: __________ nomenclature: Portable Density Meter For Petroleum Products unit Of Issue: Ea quantity: 0002 description: Shall Adhere To Astm D4052 Standard Test Method For Density, Relative Density, And Api Gravity Of Liquids By Digital Density Meter. electrical Requirements: N/a accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Anton Paar Dma 35 Ex Petrol clin 0002 unit Price: ___________ nomenclature: Shipping description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address To: flc Regional Jacksonville fuel Department 8808 Somers Road S jacksonville, Fl 32226-2600 pr Group 09 clin 0001 location: Pt. Loma, Ca Usa unit Price: ____________ nomenclature: Programmable Ashing Furnace unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D874 Standard Test Method For Sulfated Ash From Lubricating Oils And Additives electrical Requirements: 115v, 50/60 Hz, Type B Plug accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Seta Stanhope 99220-2 clin 0002 unit Price: ____________ nomenclature: Shipping description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Adress To: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 10 clin 0001 location: Pt. Loma, Ca Usa unit Price: ___________ nomenclature: Hydrogen Gas Generator unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Requirements Presented In Astm D8144 Standard Test Method For Hydrocarbon Types In Middle Distillates, Including Biodiesel Blends By Gas Chromatography/mass Spectrometry electrical Requirements: 115v, 50/60 Hz, Type B Plug output Of At Least 500 Ml/min At >99.999% accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Perkin Elmer Pg Plus N9308580 Or Equivalent clin 0002 unit Price: ____________ nomenclature: Shipping description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Adress To: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 11 clin 0001 location: Pt. Loma, Ca Usa unit Price: _____________ nomenclature: Laboratory Shaker (vertical & Horizontal) unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D5006 Standard Test Method For Measurement Of Fuel System Icing Inhibitors (ether Type) In Aviation Fuels. electrical Requirements: 120v, 50/60 Hz, Type C Plug accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Yamato Sa300, Or Equivalent clin 0002 unit Price: ___________ nomenclature: Shipping For To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 12 clin 0001 location: Pt. Loma, Ca Usa unit Price: _____________ nomenclature: Refractometer, Digital unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D5006 Standard Test Method For Measurement Of Fuel System Icing Inhibitors (ether Type) In Aviation Fuels. electrical Requirements: N/a accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Gammon Sc-b/2hb clin 0002 unit Price: ___________ nomenclature: Shipping To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 13 clin 0001 location: Pt. Loma, Ca Usa unit Price: ____________ nomenclature: Liquid Bath For Oxidation Stability Of Gasoline Test unit Of Issue: Ea quantity: 01 description: Shall Adhere To Requirements In Astm D525, D873, And D5304. electrical Requirements: 120v, 50/60 Hz capable Of Maintaining 60-120 °c +/- 0.1 °c capable Of Mechanical Agitation Of Liquid To Ensure Heat Uniformity. accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. At Least One Set Of Accessories To Successfully Run At Least One Sample. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. clin 0002 unit Price: ____________ nomenclature: Shipping To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 14 clin 0001 location: Pearl Harbor, Hi Usa unit Price: _______________ nomenclature: Sulfur And Nitrogen Analyzer, Uvf unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D5453/d4629 electrical Requirements: 120v, 50/60 Hz, Type B Plug peripherals Needed To Operate Instrument (data Processor, Monitor, Keyboard, Mouse, Printer) accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. approx. 90 Lbs (41 Kg) physical Dimensions Of Approx. 100 X 55 X 51.5 Cm Or 52.5 X 55.5 X 51.5 Cm autosampler Attachment all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Pac Elements Vertical Combustion Analyzer, Sulfur + Nitrogen (38.00.003) clin 0002 unit Price: ______________ nomenclature: Shipping For Clin 0001 To Pearl Harbor, Hi Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Pearl Harbor Fuel Terminals Laboratory 300 Neches Street Building 1685 honolulu, Hawaii 96860 clin 0003 unit Price: ___________ nomenclature: Installation For Pearl Harbor, Hi Usa description: Initial On-site Installation/calibration After Equipment Arrival And Laboratory Confirming They Are Prepared. pr Group 15 clin 0001 location: Pearl Harbor, Hi Usa unit Price: _____________ nomenclature: Freeze Point, Viscosity, And Density Analyzer (3-in-1) unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D5972/d7945/d4052 electrical Requirements: 120v, 50/60 Hz, Type B Plug accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Phase Jfa-70xi clin 0002 unit Price: _________________ nomenclature: Shipping For Clin 0001 To Pearl Harbor, Hi Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Pearl Harbor Fuel Terminals Laboratory 300 Neches Street Building 1685 honolulu, Hawaii 96860 pr Group 16 clin 0001 location: Pt. Loma, Ca Usa unit Price: ____________ nomenclature: Freeze Point, Viscosity, And Density Analyzer (3-in-1) unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D5972/d7945/d4052 electrical Requirements: 120v, 50/60 Hz, Type B Plug accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Phase Jfa-70xi clin 0002 unit Price: ____________ nomenclature: Shipping For Clin 0001 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 17 clin 0001 location: Jacksonville, Fl Usa unit Price: _______________ nomenclature: Freeze Point, Viscosity, Density, Pour Point, Cloud Point Analyzer (5-in-1) unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D5972/d7945/d4052/d97/d2500 electrical Requirements: 120v, 50/60 Hz accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Phase Jfa-70xi-pc clin 0002 unit Price: _____________ nomenclature: Shipping For Clin 0001 To Jacksonville, Fl Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional Jacksonville fuel Department 8808 Somers Road S jacksonville, Fl 32226-2600 pr Group 18 clin 0001 location: Puget Sound, Wa Usa unit Price: ____________ nomenclature: Freeze Point, Viscosity, Density, Pour Point, Cloud Point Analyzer (5-in-1) unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D5972/d7945/d4052/d97/d2500 electrical Requirements: 120v, 50/60 Hz accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Phase Jfa-70xi-pc clin 0002 unit Price: __________ nomenclature: Shipping For Clin 0001 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional Puget Sound manchester Fuel Department, Bldg. 194 7501 Beach Drive East port Orchard, Wa 98366 pr Group 19 clin 0001 location: Pearl Harbor, Hi Usa unit Price: _______________ nomenclature: Tribology Instrument, High Frequency Reciprocating Rig (hfrr) unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D6079 Standard Test Method For Evaluating Lubricity Of Diesel Fuels By The High-frequency Reciprocating Rig (hfrr) electrical Requirements: 120/220v, 50/60 Hz peripherals Needed To Operate Instrument (data Processor, Monitor, Keyboard, Mouse, Printer) humidity Cabinet microscope With Digital Camera accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Pcs Hfrr clin 0002 unit Price:__________ nomenclature: Shipping For Clin 0001 To Pearl Harbor, Hi Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Pearl Harbor Fuel Terminals Laboratory 300 Neches Street Building 1685 honolulu, Hawaii 96860 pr Group 20 clin 0001 location: Pt. Loma, Ca Usa unit Price: ___________ nomenclature: Tribology Instrument, High Frequency Reciprocating Rig (hfrr) unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D6079 Standard Test Method For Evaluating Lubricity Of Diesel Fuels By The High-frequency Reciprocating Rig (hfrr) electrical Requirements: 120/220v, 50/60 Hz peripherals Needed To Operate Instrument (data Processor, Monitor, Keyboard, Mouse, Printer) humidity Cabinet microscope With Digital Camera accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Pcs Hfrr clin 0002 unit Price: _________ nomenclature: Shipping For Clin 0001 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 21 clin 0001 location: Pearl Harbor, Hi Usa unit Price: __________ nomenclature: Analytical Balance unit Of Issue: Ea quantity: 01 description: Shall Adhere To Astm D5452/d6217 electrical Requirements: 120v, 50/60 Hz 220 G Capability With 0.01 Mg Readability. accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Mettler Toledo Xpr205 clin 0002 unit Price: __________ nomenclature: Shipping For Clin 0001 To Pearl Harbor, Hi Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Pearl Harbor Fuel Terminals Laboratory 300 Neches Street Building 1685 honolulu, Hawaii 96860 pr Group 22 clin 0001 location: Pt. Loma, Ca Usa unit Price: ____________ nomenclature: Titrator, Karl Fischer, Automated, 120v unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D6304 Standard Test Method For Determination Of Water In Petroleum Products, Lubricating Oils, And Additives By Coulometric Karl Fischer Titration electrical Requirements: 120v/220v, 50/60 Hz, Type B Plug accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Mettler Toledo C10s clin 0002 unit Price: __________ nomenclature: Shipping For Clin 0001 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 23 clin 0001 location: Pt. Loma, Ca Usa unit Price: ____________ nomenclature: Fatty Acid Methyl Ester (fame) Analyzer For Multiple Fuel Types unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D7797 Standard Test Method For Determination Of The Fatty Acid Methyl Esters Content Of Aviation Turbine Fuel Using Flow Analysis By Fourier Transform Infrared Spectroscopy—rapid Screening Method electrical Requirements: 120v, 50/60 Hz accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Fiji Fame Mf clin 0002 unit Price:_________ nomenclature: Shipping For Clin 0001 To Pt. Loma, Ca Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional San Diego Petroleum Laboratory bldg 70a 199 Rosecrans Street san Diego Ca 92106 pr Group 24 clin 0001 location: Anchorage, Ak Usa unit Price: __________ nomenclature: Distillation Analyzer, Automated, 120v unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D86 Standard Test Method For Distillation Of Petroleum Products And Liquid Fuels At Atmospheric Pressure electrical Requirements: 120v, 50/60 Hz built-in Fire Extinguisher With Ir Sensor For Fire Detection. accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Anton Paar Diana 700 clin 0002 unit Price: __________ nomenclature: Shipping For Clin 0001 To Anchorage, Ak Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: petroleum Laboratory jber, Ak 99505 pr Group 25 clin 0001 location: Pearl Harbor, Hi Usa unit Price: _____________ nomenclature: Foam Digital Detection Imaging Test Apparatus unit Of Issue: Ea quantity: 0002 description: Shall Adhere To Astm D892/d6082 electrical Requirements: 110v, 50/60 Hz, 3.2a, Type B Plug digital Image Detection And Capture Of Foam Tendency And Stability. accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. include An Air Pump, Cylindrical Diffusers, And 2 Modules this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Visaya Foam Ddi clin 0002 unit Price:___________ nomenclature: Shipping For Clin 0001 To Pearl Harbor, Hi Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Pearl Harbor Fuel Terminals Laboratory 300 Neches Street Building 1685 honolulu, Hawaii 96860 clin 0003 unit Price: _____________ nomenclature: Installation For Pearl Harbor, Hi Usa description: Initial On-site Installation/calibration After Equipment Arrival And Laboratory Confirming They Are Prepared. pr Group 26 clin 0001 location: Puget Sound, Wa Usa unit Price: _____________ nomenclature: Laboratory Water Purification System unit Of Issue: Ea quantity: 0001 description: electrical Requirements: 120v, 50/60 Hz accessory Kit Including All Items Needed To Utilize Equipment Shall Be Included In The Price And Shipped With The Equipment. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Mfg: Milli-q Iq 7015 clin 0002 unit Price: ___________ nomenclature: Shipping For Clin 0001 To Puget Sound, Wa Usa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional Puget Sound manchester Fuel Department, Bldg. 194 7501 Beach Drive East port Orchard, Wa 98366 clin 0003 unit Price: __________ nomenclature: Installation For Puget Sound, Wa description: Initial On-site Installation/calibration After Equipment Arrival And Laboratory Confirming They Are Prepared. pr Group 27 clin 0001 location: Puget Sound, Wa unit Price: ____________ nomenclature: Dual-bath Kinematic Viscometer unit Of Issue: Ea quantity: 0001 description: Shall Adhere To Astm D445, Standard Test Method For Kinematic Viscosity Of Transparent And Opaque Liquids. electrical Requirements: 120v, 50/60 Hz accessory Kit Including All Items Needed To Utilize And Calibrate Equipment Shall Be Included In The Price And Shipped With The Equipment. capability To Analyze Two Samples At Different Temperatures Simultaneously. all Instrument Documentation (if Provided Electronically) Shall Be Provided Via Either Email Or On A Cd/dvd. the Equipment Shall Include A One-year Warranty. shall Be Able To Provide Technical Support Via Phone, Email Or Video Conference. this Is A Brand Name (reference Far 52.211-6) Reference Mfg: Cannon Cav 4.2 (9725-b35) for Testing Lubricating Oils And Diesel. Expected Viscosity Ranges Would Be 77 – 97 Mm2/s At 40c For Lubes And 1.7 – 4.3 Mm2/s At 40c For Diesel. We Would Also Test The Lube Oils At 100c With A Minimum Limit Of 8.0 Mm2/s. clin 0002 shipping unit Price:____________ nomenclature: Shipping Topuget Sound, Wa description: Request Third Party Priority Shipping With (fedex, Usp, Dhl, Usps, Etc) With Tracking Number. shipping Address Is: flc Regional Puget Sound manchester Fuel Department, Bldg. 194 7501 Beach Drive East port Orchard, Wa 98366 clin 0003 installation unit Price: _____________ nomenclature: Installation And Training At Puget Sound, Wa description: Initial On-site Installation/calibration Of Instrument. required Delivery Date: 09/30/2024 Through 12/31/2024 quotation Due Date: All Quotes Must Be Submitted By Email To Contract Specialist, Hannah Savine At Hannah.r.savine@dla.mil And Dlaenergyfepab@dla.mil No Later Than 10:00 Pm Eastern Standard Time (ft. Belvoir, Va) Time On September 24, 2024. please Direct Questions To The Point Of Contact: hannah Savine Contract Specialist Dla Energy Phone: (570) 837-1653 email: Hannah.r.savine@dla.mil vendors Are Responsible For Ensuring All Applicable Taxes And Fees Are Included In Their Quoted Prices. dla Energy May Require A Vendor To Sign The Sf1449 Prior To Being Awarded This Delivery. This Will Be Sent By Email And May Have A Response Window Of As Little As Two (2) Hours. Upon Request, The Vendor Must Return The Signed Sf1449 By The Deadline Specified. If This Is Not Returned By The Specified Deadline, Dla Energy Reserves The Right To Offer This Delivery To A Different Vendor. electronic Funds Transfer As A Means Of Payment Will Be Made Upon Receipt And Acceptance Of All Products Through Wide Area Work Flow (wawf). dfars 252.232-7006 Wide Area Workflow Payment Instructions (jan 2023) far 52.212-1, Instructions To Offerors Commercial Items Applies To This Acquisition. far 52.212-2 Evaluation Of Commercial Items Applies To This Acquisition. The Evaluation Criteria Stated In Paragraph (a) Of Far 52.212-2 Are As Follows: The Contract Will Be Awarded To The Lowest Price Quotation From A Responsible Vendor. vendors Shall Include A Completed Copy Of Far 52.212-3 Offeror Representations And Certifications Commercial Items With Its Quotation. A Printout From Sam.gov Is Acceptable. far 52.212-4, Contract Terms And Conditions Commercial Items Applies To This Acquisition. far 52.212-5 Contract Terms And Conditions Required To Implement Statutes Or Executive Orders – Commercial Items Applies To This Acquisition. In Paragraph (b) Of Far 52.212-5, The Following Apply: Far52.209-6, 52.219-6, 52.219-28, 52.222-3, 52.222-19, 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-50, 52.225-13, 52,232-33, 52.204-10 the Following Additional Clauses Apply To This Acquisition: Far 52.204-7, 52.204-13, 52.204-18, 52.204-21, And 52.247-34. defense Federal Acquisition Regulation Supplement (dfars) 252.203-7002 ,252.203-7005, 252.204-7003, 252.204-7008, 252.204-7012 , 252.204-7015, 252.225-7012, 252.229-7001, 252.225-7000, 252.225-7001, 252.225-7002, 252.232-7003, 252.232-7006, 252.243-7001, 252.244-7000, And 252.247-7023. (see Attached)
St Anthony Mother And Child Hospital Tender
Machinery and Tools
Philippines
Closing Date1 Apr 2024
Tender AmountPHP 435.2 K (USD 7.7 K)
Details: Description Request For Quotation (np-small Value Procurement) Rfq No. : 2024-065 Date : 03/22/2024 Pr No. : 24-03-008/094 End User : L. Almirante/housekeeping Name Of Company : Address: Contact No. Philgeps Registration No. Please Quote Your Best Offer For The Item/s Described Herein, Subject To The Following Conditions: 1 Accomplished This Request For Quotation (rfq) Correctly And Accurately With A Non-extendable Period According To The Deadline Set For Submission. 2 Price Quotation/s Must Be Valid For A Period Of Sixty (60) Calendar Days From The Date Of Submission. 3 All Technical Specifications Are Mandatory. Failure To Comply With Any Of The Mandatory Requirements Will Disqualify Your Quotation. 4 Quotations May Be Submitted Through Facsimile Thru No. 261-9989 Local 5101 Or Thru Email Address At Bac@samch.doh.gov.ph On Or Before April 1,2024 @ 5:00 Pm 5 Management Reserves The Right To Reject Outright Any Contingent Bids. 6 Participating Suppliers/service Providers Are Encouraged To Have An Existing Landbank Of The Philippines (lbp) Account In Compliance To Dbm Circular Letter No. 2013-16. Documentary Requirements 1 Latest Business/mayors Permit Atty. Ellen R. Nalia 2 Philgeps Registration Number Chairperson, Bids And Awards Committee 3 Notarized Omnibus Sworn Statement, Shall Be Required Prior To Award Incomplete Documentary Requirements And Quotations Received After The Submission Deadline, For Whatever Reason, Will Not Be Considered For Evaluation.thank You And We Look Forward To Receiving Your Quotation. After Having Carefully Read And Accepted The Terms And Conditions In The Request For Quotation, Hereunder Is Our Quotation For The Item/s As Follows: Procuring Entity Supplier's Offer Bac Item No. Item & Description Uom Qty Approved Budget For The Contract ( Total ) Unit Price Total Brand, If Applicable Remarks Unit Price Total 1 All Purpose Cleaner Gal 35 550.00 19,250.00 Composition: Water, Plant-derived Surfactant, Plant-derived Solvent, Natural Fragrance, Food Grade Preservative, Plant-derived Ph Adjuster Ph 9.0 - 10.0; Anti-bacterial; Appearance And Odor: Clear Yellow Liquid With Lemon Fragrance;eco-friendly 2 Carpet Shampoo Gal 15 600.00 9,000.00 Clear, Homogeneous Liquid, Free From Impurities, Ph: 6 – 8.5 Volume: At Least 3.5l Composition: Aqua, Sodium Gluconate, Alcohol Ethoxylate, Fragrance Anti-bacterial Eco-friendly 3 Chlorine Powder 1kg Kg 40 330.00 13,200.00 =70% Calcium Hypochlorite, Hydrated <20%: Sodium Chloride, Calcium Chloride, Calcium Hydroxide, Calcium Chlorate Branded 4 Declogger Gal 12 4,400.00 52,800.00 Concentrated Alkaline Based Ph Level: 9.1 - 9.5 Biodegradable Properties: Water, Bacteria Cultures, Biodegradable Surfactant, Limonene Fragrance Standard: Osha With Packaging Label 5 Deodorizer Gal 12 13,200.00 158,400.00 Eco-friendly/organic Properties: Mono-distilled, Water, Sodium Chloride, Limonene Fragrance With Packaging Label 6 Detergent Powder (anti-bacterial) Kilo 200 150.00 30,000.00 At Least 1kg Per Pack Composition: A.linear Alkylbenzene Sulfonate B.detergent Builders C.anti-soil Redeposition Agent D.brightening Agent E.enzymewith Anti-bacterial Agent For Eliminating Germs/bacteria Must Be Compatible With All Types Of Washable Fabrics Suitable For Hand And Machine Laundry Less Ash Built-up/deposited On The Washed Fabric High Foaming Generation Iso Certified; Pns 23:2002 Standard With Packaging Label;branded; Eco-friendly 7 Disinfectant Concentrates Bot 40 500.00 20,000.00 Volume: At Least 1l Anti-bacterial Eco-friendly: Biodegradable Disinfectant Branded 8 Fabric Conditioner At Least 690ml Pack 100 220.00 22,000.00 Composition: Plant-derived Cationic Surfactant, Lactic Acid, Plant-derived Parfum (limonene), Water, Propylene Glycol, Lecithin, Magnesium Chloride Eco-friendly With Packaging Label; Branded; 9 Heavy Duty Scrub Sponge Pc 160 50.00 8,000.00 10 Liquid Bleach Gal 200 240.00 48,000.00 Anti-bacterial Composition: Oxygen-based Bleaching Agent, Sodium Sulfate, Sodium Bicarbonate, Glycerin With Packaging Label Branded 11 Muriatic Acid Gal 48 400.00 19,200.00 20 Baume Concentration Range (%hci) – 31.5 – 32.9 Boiling Point - 84°c Freezing Point - -44.5°c Vapor Pressure (mm Hg) – 24 Specific Gravity – 1.160 Bulk Density (lbs./gal @ 15.6°c) – 9.7 Branded 12 Round Rags Pc 200 20.00 4,000.00 Material: Cotton 13 Toilet Bowl Cleaner Gal 96 275.00 26,400.00 Composition: Sodium Hypochlorite, Lauramine Oxide, Sodium Hydroxide, Myristamine Oxide Branded Supplier Must Submit Product Safety Data Sheet Supplier Must Submit Sample Which Will Be Subject For Evaluation/approval 14 Toilet Brush Pc 30 165.00 4,950.00 Multi-purpose Scrub Has Polypropylene Bristles With Handle Additional Requirements: Supplier Must Submit Product Safety Data Sheet Supplier Must Submit Sample Which Will Be Subject For Evaluation And Approval Delivery: Seven (7) Days Payment: Thirty (30) Days After Delivery Total 435,200.00 Note: Award Shall Be Made On Per: O Item Basis O Lot Basis Þ Total Quoted Price "delivery Period: 7 Calendar Days " Warranty: ________________________________, If Applicable Submitted By: Canvassed By: Date: Authorized Representative / Date Printed Name / Signature:
Department Of Education Division Of Quezon Tender
Education And Training Services
Philippines
Closing Date22 Apr 2024
Tender AmountPHP 400 K (USD 6.9 K)
Details: Description Bids And Awards Committee Rfq No. 2024-022-rfqs Date :april 16,2024 Request For Quotation The Department Of Education, Division Of Quezon, Through Its Bids And Awards Committee (bac), Will Undertake A Negotiated Procurement Through Small Value Procurement For The Requirement On Services On Repair And Replacement Of Computer Parts Under Deped Computerization Program (dcp) On Various Schools Within 100 Calendar Days Upon Issuance Of Notice To Proceed In Accordance With Section 53.2 Of The Implementing Rules And Regulations Of Republic Act No. 9184. Name Of Project : Services On Repair And Replacement Of Computer Parts Under Deped Computerization Program (dcp) On Various Schools Approved Budget For The : Four Hundred Thousand Two Hundred Pesos Only (p400,000.00) Specifications : See Attached Annex “a” For The Detailed Requirements Location : Deped Division Of Quezon Delivery Term : Within One Hundred 100) Calendar Days Upon Receipt Of Notice To Proceed Interested Suppliers Are Required To Submit Their Valid And Current Mayor’s Permit, Income/business Tax Return (for Abcs Above Php500k), Philgeps Registration And Omnibus Sworn Statement, Upon Submission Of Quotation. Philgeps Platinum Membership May Be Submitted In Lieu Of The Mayor’s/ Business Permit And The Philgeps Registration Number. Award Of Contract Shall Be Made To The Lowest Quotation On A Per Lot Basis, Which Complies With The Minimum Description As Stated Above And Other Tems And Conditions Stated In The Price Quotation Form. Any Interlineations, Erasures Or Overwriting Shall Be Valid Only If There Are Signed Or Initialed By The Bidder Or His/her Duly Authorized Representative/s. Submission Of Quotation And Eligibility Documents Is On Or Before 9:00a.m. Of April 22, 2024 At Deped, Division Of Quezon, Talipan, Pagbilao, Quezon. Please Submit Your Quotation In A Sealed Envelope Addressed To: Joepi F. Falqueza, Edd Bac Chairman Deped- Division Of Quezon Talipan, Pagbilao, Quezon For Inquiries, You May Contact Us At Tel. Nos. 042-784-0366 Look For Floricel R. Lagos Very Truly Yours, Joepi F. Falqueza, Edd Bac Chairman Annex “a” Price Quotation Form ____________________ Date The Bids And Awards Committee Deped, Division Of Quezon Talipan. Pagbilao, Quezon Sir/madam: Project Description Item No. Item Description Total Cost Supplier Unit Cost Supplier Total Cost Services On Repair And Replacement Of Computer Parts Under Deped Computerization Program (dcp) On Various Schools Lot 1 Repair And Replacement Of Computer Parts P400,000.00 Total Abc--------------------------------------------------p400,000.00 After Having Carefully Read And Accepted The Terms And Conditions In The Request For Quotation, Hereunder Is Our Quotation/s For The Item/s, As Follows: Total Amount In Words __________________________________________________________________________________________ _________________________________________________________________________________________ _______________________________ Signature Over Printed Name Of Bidder Terms Of Reference Project Title Services On Repair And Replacement Of Computer Parts Under Deped Computerization Program (dcp) Budgetary Requirements Php 400,000.00 Mode Of Procurement Small Value Procurement (svp) Procuring Entity Deped Schools Division Of Quezon Province Location Sitio Fori, Brgy. Talipan, Pagbilao, Quezon Item/s Lot 1: Services On Repair And Replacement Of Computer Parts Under Deped Computerization Program I. Budgetary Requirements Dcp Qty Unit Unit Cost Total Cost 1 Services On Repair And Replacement Of Computer Parts Under Deped Computerization Program (dcp) 1 Lot 400, 000.00 400,000.00 For Lot 1: A) The Prospective Bidder Must Have Proof Of Existing Repair And Replacement Under Deped Computerization Program B) The Prospective Bidder Must Present Their Detailed Process Flow Of Rendering Repair And Replacement Through Flow Chart C) The Prospective Bidder Must Have Have The Certification Of Authorized Service Partner D) Proposed Work Plan And Detailed Implementation Schedule For The Project Covering The Whole Period. Prospective. This Is To Ensure The Reliability, Security, And Efficiency Of The Required Services That The Prospective Bidder Shall Perform. The Timeframe Should Be Specified For Each Activity To Be Done And Should Include Gantt Chart Summary. E) The Prospective Bidder Must Issue 30 Days Warranty Upon Repair Of The Unit And 90 Days On Warranty On Parts F) The Prospective Bidder Service Personnel Must Present Certification Of Service Engineer G) The Prospective Bidder Must Diagnose The Computer Unit Physically In School Beyond 50 Kilometers, Otherwise Beyond 50 Kilometres The Physical Unit Must Delivered To The Prospective Bidder. H) This Project Duration Is 90 Calendar Days Upon Approval Of The Ntp. Other Documentary Requirements To Be Submitted By Bidder: 1. Winning Bidder In Close Coordination With The School End User On Their Technical Concerns On How The Computer Unit Will Undergo Repair And Costing Of Defective Computer Parts. 2. The Completion Schedule Provided Shall Be Considered Extended Under The Following: • Delays Caused By Force Majeure Events; • Delays Caused By Special Cases And Events Beyond Control, Subject For Evaluation And Approval By Deped Quezon. 3. In All Cases, The Period Or Number Of Days Of Extension Shall Be Agreed Upon With The Deped Quezon In Writing. 4. Claims For Time Extension Of The Contract Period Due To Force Majeure Shall Be Subject To Approval By Deped Quezon. 5. Force Majeure Includes Events Such As Earthquake, Flood, Typhoon, Cyclone, Revolution, War And Other Cataclysmic Phenomena Of Nature And Misfortune Which Are Beyond Human Prudence And Foresight. Iv. Duties And Responsibilities Of Deped Quezon A. Assist Prospective Bidders During The Conduct Of School Diagnostic. B. Grant The Prospective Bidder Authorized Representative Access To Its Premises And Facilities Located Therein To Perform Its Obligations, Provided That Such Representative Shall Be Accompanied By The Duly Assigned Deped Quezon Personnel. C. Pay The Prospective Bidder In Accordance With Conditions Set In The Payment Scheme. D. Issue A Certification Of Inspection And Acceptance. V. Technical Specifications See Annex A I Hereby Certify To Comply With All The Above Technical Specifications. _____________ _____________________________________________ _______________ Name Of Bidder Signature Over Printed Name Of Representative Date Annex A List Of Schools With Dcp Units For Repair As Of February 2, 2024 No. Cong. District School Id School Name Address Dcp Batch No. Defective (e.g. Ssd Hard Drive) Specification (e.g. 500gb Hard Drive) 1 1st General Nakar I 108708 General Nakar Ces Brgy. Poblacion Gen. Nakar Quezon Batch 30 & 29 Not Functional Desktop Units 2 1st Infanta 301410 Tongohin Nhs Brgy. Tongohin, Infanta, Quezon Batch 36 & Batch 2019-03 Lcd 14" Display / Keyboard (laptop) Intel Core I5 2.5ghz/8gb Dd4r And Amd Ryzen 5 2500u, 2.0ghz Base Frequency, 4 Cores, 8 Threads, 4mb L3 Cache 3 1st Lucban 108867 Paaralang Elem Ng Lucban 4 A. Racelis Ave. Brgy Ayuti Lucban, Quezon Batch 40 Acer Laptop Battery Acer N16q1 Battery 4 1st Mauban North 165010 Tejero Es Brgy. Lual Bario Mauban, Quezon Batch 42 Not Functional Desktop Units 5 1st Mauban South 165006 Mauban South Central Es Ii Brgy. Rizaliana, Mauban, Quezon Batch 42 Not Functional Desktop Units 6 1st Pagbilao I 108974 Parang-pinagbayanan Es Martinez St. Bgry. Parang Pagbilao Quezon Batch 2020 2 Batteries, 7 1st Panukulan 109021 Balungay Es Brgy.balungay, Panukulan, Quezon Batch 26 &29 2 Batteries, Keyboard - 8 1st Polillo 301382 Sabang Nhs Brgy.sabang, Polillo,quezon Batch 35 & 36 Computer Units Desktop And Monitors 9 1st Real 109067 Llavac Es Brgy. Llavac Real, Quezon Batch 42 Ktc Led Tv 50", Host Mini Pc Acer Veriton X4650g 10 2nd Candelaria East 108624 Masalukot V Es Masalukot V Candelaria, Quezon Batch 26 Ssd Hard Drive 500gb Hard Drive 11 2nd Candelaria West 108633 Buenavista West Es Buenavista West Candelaria, Quezon Batch 2020 Hard Drive Hard Drive 12 2nd Dolores 301317 Dagatan Nhs Purok2, Dagatan Dolores, Quezon Batch 33 Hard Drive 500g Ssd Hard Drive 13 2nd San Antonio 109112 San Antonio Cs Poblacion, San Antonio, Quezon Hard Drive 500gb Ssd Hard Drive 14 2nd Sariaya East 109161 Canda Es Brgy. Canda, Sariaya, Quezon Batch 29 Laptop Battery And Keyboard 15 109172 Tumbaga 2 Es Sitio Jasmin, Brgy. Tumbaga 2, Sariaya Quezon Batch 40 Laptop Battery 16 2nd Sariaya West 109179 Emiliano Gala Es Brgy. Concepcion I Sariaya, Quezon Batch 29 Installation Of Dcp All Units 17 2nd Tiaong Ii 109280 Palagaran Elementary School Brgy. Palagaran, Tiaong, Quezon Batch 2021 Keyboard (for Replacement) Coby Nbpc 2168 18 3rd Agdangan 108944 Agdangan Ces Brgy. Pob.1, Agdangan, Quezon Batch 29 Laptop, Computer Units Motherboard, N Computing 19 3rd Buenavista I 108537 Buenavista Ces Brgy. Poblacion Buenavista, Quezon Batch 30 & 29 Not Functional Desktop Units 20 3rd Buenavista Ii 108543 Hagonghong Es Brgy. Hagonghong Buenavista, Quezon Batch 29 & Dcp 2020 Laptop (battery Replacement) Projector (lens Replacement) Samsung Smart Led Tv 55" No Display 1 Laptop, 1 Projector, 1 Smart Led Tv 21 3rd Catanauan I 108643 Ajos Es Brgy. Ajos, Catanauan, Quezon Batch 29 & Dcp 2020 Hard Drive 2 Pcs. 500gb Hard Drive 22 3rd Catanauan Ii 108671 Tuhian Es Brgy Tuhian Catanauan Quezon Batch 42 Board 2 Laptop 23 3rd General Luna 108684 Bacong Ibaba Es Brgy. Bacong Ibaba General Luna, Quezon Batch 2020 Laptop Lcd, Keyboard, And Keyboard Power Switch Laptop And Keyboard 24 3rd Mulanay I 301295 Bondoc Peninsula Agricultural Hs Brgy. Sta. Rosa, Mulanay, Quezon Batch 2020 Hdd Crashing 2 Tb Hdd Sata 5400 Rpm 25 3rd Mulanay Ii 108941 San Pedro Es Brgy. San Pedro Mulanay, Quezon Batch 2021 Laptop 1 Laptop 26 3rd Padre Burgos 301137 Lina Gayeta Lasquety Nhs Brgy. Kinagunan Ibaba, Padre Burgos, Quezon Dcp - Tvl Hdd Crashing/ Ram 500 Gb M.2 Sata Or 1tb Ssd/ 2pcs Ram 27 3rd Pitogo 109014 Sumag Es Brgy. Sumag Este, Pitogo, Quezon Batch 29 Batch 42 Laptop Battery Ktc 55 Inches Lcd Hp Hs04 Rechargable Battery Acer Battery Laptop Ktc 55 Inches Lcd 28 3rd San Andres 109088 Alibihaban Es Brgy. Alibihaban San Andres Quezon Batch 40 And 34 Speaker, Headset Port, 2 Usb Port, Battery 29 3rd San Francisco I 301309 Casay Nhs Brgy. Casay San Francisco, Quezon Batch 36 System Unit Power Supply 30 3rd San Francisco Ii 109135 Tumabaga Es Brgy. Pagsangahan, San Francisco, Quezon Batch 40 Battery 31 3rd San Narciso I 301322 Gregorio Reyes Nhs Brgy. Villa Reyes , San Narciso, Quezon Batch 36 Computer Units/laptop Desktop Units/battery 32 3rd San Narciso Ii 301280 Abuyon Nhs Brgy. Abuyon, San Narciso, Quezon Batch 36 And 33 Defective Laptop Acer Battery And Hp Laptop Keyboard Acer P249 Series Laptop Model No. N16q1 And Hp 33 3rd Unisan 109306 Unisan Ces Brgy. F. De Jesus, Unisan, Quezon Batch 40 & 2019-01 Tv, Laptop Smart Tv, Motherboard 34 4th Atimonan I 301286 Atimonan Nchs Soler St. Extension, Brgy. Angeles, Atimonan, Quezon Batch 33 Hdd Crashing; Laptops Almost Always No Power; If Able To Start, Processes Are Very Slow (always Freezing To The Point That A Hard Restart Is Almost Always Required) 500gb Hdd [256 To 512gb Ssd (recommended)] 35 4th Atimonan Ii 108517 Magsaysay Es Atimonan, Quezon Batch 22 Mother Board Mother Board 36 4th Guinayangan North 108745 San Luis Ii Es Brgy. San Luis Guinayangan Quezon Batch 29 Not Functioning 37 4th Guinayangan South 108738 Guinayangan Es Brgy. Manggagawa Guinayangan, Quezon Batch 30 Ups Model No. Psa1000mt3-230u (emerson Network Power) 38 4th Gumaca East 108759 Gumaca Ces Brgy. Villa Nava Gumaca, Quezon Batch 29 Hard Drive 384 Gb Laptop 4ekkkrvb 39 4th Gumaca West 108771 Pagsabangan Es Brgy. Pagsabangan Gumaca, Quezon Batch 42 Hard Drive 8gb 40 4th Lopez East 108812 Magallanes Es Brgy. Magallanes Lopez Quezon Batch 29 Battery And Lcd Battery And Lcd 41 4th Lopez West 108843 Hondagua Es Brgy. Hondagua Lopez, Quezon Batch 2019 Laptop Battery 42 4th Plaridel 109018 Tanauan Es Brgy. Tanauan, Plaridel, Quezon Batch 40 Acer Laptop-battery Acer Battery Charger Charger 19v, 3.42a Hp Laptop Charger Keyboard Acer Keyboard 43 4th Quezon 109058 R.sasot Es Brgy. Argosino Quezon, Quezon 44 4th Tagkawayan I 109221 San Isidro Es Brgy. San Isidro , Batch 29 Charger Laptop Charger 45 109219 San Diego Es Brgy. San Diego Batch 42 Battery Acer Travel Mate P249 Series Model No. N16q1 (battery) 46 109199 Cabibihan Es Brgy. Cabibihan Batch 29 Charger 47 4th Tagkawayan Ii 301406 Tagkawayan Nhs Brgy. Munting Parang Tagkawayan Quezon Batch 36 Laptop Screen Acer P249 Series Model No. N16q1 Laptop Screen 48 4th Gumaca West 108775 Sastre Es Brgy. Sastre Gumaca, Quezon Batch 42 Cpu Hard Disk: 500gb 7200 Rpm (sata) Monitor: Acer 18.5 Lcd/led Backlit, 1280 X 1024 Resolution Keyboard: Acer, Usb Us English Layout 307,200.00 24,303.00 Checklist Of Eligibility And Technical Documents For Submission Class “a” Documents 1. Legal Documents • Philgeps Registration • Mayor’s/business Permit • Dti Or Sec Registration • Bir Certificate Of Registration • Income/business Tax Return (for Abcs Above 500k) 2. Technical Documents • Notarized Omnibus Sworn Statement • Authority Of The Signatory 3. Financial Documents • Original Of Duly Signed And Accomplished Quotation Form; Class “b” Documents • Jva Or The Duly Notarized Statement In Accordance With Section 23.1(b) Of The 2016 Revised Irr, If Applicable Notes: 1. All Documents Must Be Prepared In Two (2) Sets Of Copies, One (1) Original Copy And One (1) Photocopy 2. The Proposal Shall Be Accompanied By The Aforementioned Documents, Otherwise, Non-submission Of Which Shall Result To Disqualification Of Proposal.
41-50 of 46 archived Tenders