Dustbin Tenders

INTEGRATED PROVINCIAL HEALTH OFFICE SULU Tender

Electrical Goods and Equipments...+1Electrical and Electronics
Corrigendum : Tender Amount Updated
Philippines
Details: Description Ref No. Item/product Description Qty Unit Abc 1 Blood Bank Refrigerator Key Features:  Inner Light Design For Clear Display  High-tech Integrated Sensors To Display And Control Temperature  Microprocessor Controlled Forced-air Cooling With Electrical Heat Compensation System  Build-in Backup Battery To Display Temperature And To Operate Audible And Visual Alarm Systems For Up To 72 Hours Without Ac Power  Equipped With A Complete Temperature Alarm System Featuring Audible Buzzer And Visible Flashing Light  Inner Light Design For Clear Display  High-tech Integrated Sensors To Display And Control Temperature  Microprocessor Controlled Forced-air Cooling With Electrical Heat Compensation System  Build-in Backup Battery To Display Temperature And To Operate Audible And Visual Alarm Systems For Up To 72 Hours Without Ac Power  Capacity :at Least 1000 Liters, Blood Bags Capacity (450 Ml) At Least 576 Bags  Compressor : Secop  Defrosting: Automatic To Remove Moisture On Cooling Surface  Alarms: Audible And Visible Alarm , High And Low Temperature, High Ambient Temperature, Sensor Error, Low Battery, Power Failure Back-up System At Least 72 Hours  Structure : Internal: Stainless Steel; Grade 304 External: Electro-galvanized Steel With Antimicrobial Powder Coating  Number Of Drawers : At Least 12  Sound Emission : 53.6 Db  Power Consumption: 415 W  Net Weight : Not More Than 265 Kg  External Dimension: Not Bigger Than 1300x960x2130mm (wxdxh) Standard Accessories:  Safety Lock To Prevent Unauthorized Access.  Twelve (12) Drawers  One (1) Unit Avr Standard Requirements:  Loa From The Manufacturer  Supplier Must Provide One (1) Copy Of Working Manual Platelet Oscillating Incubator(platelet Agitator/incubator) Specifications:  Must Be Sus Oscillator, With Mirror Surface Sus Shelves, Box Foamed With High Density Non-cfc Material And Imported Oscillation Slide Rail  Can Store Blood Platelet Including Biological Reagent, And Chemical Products At 2-40 ℃ With Microprocessor Temperature, Inner Temperature Controlled In 22 ℃+/- 2 ℃  Compressor Must Be Cfc-free Refrigerant With Uv For Disinfection And Turns Off While Door Is Open, Temperature Printer Can Be Set Freely  Voltage : 187 To 242v, With Power On/off, Transparent Insulated Glass Door, And Digital Display, No Frost, With Forced Air-cooling System  Capacity : Not Less Than 5 L/cu.ft, Can Accommodate Not Less Than 10 Blood Bags Per Layer, Has 5 Layers, Two Alarm Style : Audible Buzzing And Visual Flashing Light  Power Consumption Not Less Than 2.69 Kwh/24h, Noise : Not More Than 49db, Ambient Temperature : 10-32 ℃, Temperature Range : 20-24 ℃, Compressor Brand : Embraco, Display : Digital Display, Voltage Frequency : 220/50hz, Power / Current : 197w/0.9a, Power Cord : Earth Leakage Protection  Material Use Must Be 304 Stainless Steel For Inside Material And Cold-rolled Steel Coated With Anti-bacteria Powder For Outside Material  Dimensions :520×640×1030 (interior), 427×360×467 (exterior), 590×695×1210 (package Size) 20gp/40gp/40hq : 24/48/96  Has Low And High Temperature Monitoring, Power Failure Alarm, Sensor Error Alarm And Door Ajar Alarm  Has Power Failure Back-up System (alarm) Of Not Less Than 72h Accessories:  Caster, Outer Foamed Glass Door, And Uv Light  One (1) Unit Avr Standard Requirements:  Supplier Must Provide One (1) Copy Of Working Manual  Supplier Must Have Ced Or Loa From The Manufacturer 1 Lot 2,079,000.00 2 Automated System For Identification And Antimicrobial Susceptibility Testing Of Gram Positive And Gram Negative Organisms Specifications:  Utilizes 96-well Microtiter Plates Using Fluorescence And Turbidimetry For Id And Susceptibility  Can Process At Least Three (3) Isolates In A Single Plate For Identification  Uses Broth Microdilution (bmd) Technique For Ast  Can Offer Cationic Mueller Hinton Broth With Tes, Htm, Camhb With Lysed Horse Blood  Can Perform Susceptibility Testing Of Colistin Using Broth Microdilution Technique As Recommended By Clsi And Eucast  Can Offer A Susceptibility Plate That Can Perform Ast For Haemophilus And S.pneumoniae Using Haemophilus Test Medium And Mueller Hinton Broth With Lysed Horse Blood Respectively  Can Offer A Susceptibility Plate For Filamentous Fungi, Yeasts, Anaerobes, Mycobacterium Tuberculosis, And Non-tb Mycobacterium  Ast Plates Can Be Read Manually, Allowing Critical Interpretation Of Unusual Patterns Eliminating The Need To Retest Invalid Results  Includes Autoinoculation Machine For Id And Ast Plates  Includes Nephelometer For Inoculum Standardization 1 Lot 2,871,000.00 3 Digital X-ray Machine With Panel Detector Product Description:  Different Types Of High Performance Generator Based On Its Own  The 4-ways Table Is Smooth, And Effortless To Float, And Consisted  With Fully Counter-balanced, The Floor-mounted Tube Stand Can  Wall Bucky Stand With Electromagnetic Lock For Easy Positioning.  User-friendly Flat Surface Control Panel.  Anatomical Programming (apr) By Morphology, View And Body  Modular Design That Saving Space To Fit Into Virtually Any Clinical Environment. Specifications: Generator  Type: High Frequency Inverter  Range: 40kw  Max. Ma/kv: 500ma/125kv  Max. Rating: 500ma@80kv  Mas Range: 0.10 - 500mas  Exposure Time: 0.001 - 6sec (81 Steps)  Apr: 288  Line Voltage & Phase: 220vac 50/60hz Single Phase Tube  Anode Heat Storage: 140 Khu  Focus Spots ( Dual): 1.0/2.0mm  Max. Ma/kv: 500ma/125kv  Target Angle: 16° (12°)  Collimator: Manual Type With Timer Tube Stand  Longitudinal Travel: 200cm  Transverse Travel: 26cm  Vertical Travel: From 40 To 190cm (from Floor Level) Bucky Table  Type: 4-way Floating Top Table  Longitudinal Travel: 90cm  Transverse Travel: 30cm  Max. Loading: 250kg  Cassette Tray: Max. 17” X 17” Wall Bucky Stand  Type: Floor Mounted  Grid: Oscillating Grid (10:1 Standard)  Vertical Travel: From 40 To 190cm (from Floor Level) Panel Detector Specifications:  Flat Panel Detector (fpd) - 14" X 17"  Console Software Image Pilot  Bone Suppression Software License Included  Scintilator Csi ( Cesium Iodide)  Pixel Size 150 Um  Aed: Autimatic Exposure Detection  Image Storage: Available ( Up To 200 Images)  Total Surface Laod 150kg  Cycle Time: First View: 4 Sec/cycle Time:10sec  Battery: Lithium Ion Battery  Battery Performance: 212 Images Or 5.9 Hours Components: 1. Aerodr Ns Flat Panel Detector  Detects X-ray And Absorbs Raditation For Image Acquisition 2. Aerodr Ns Battery Charger  Charges Battery Of The Flat Panel Detector 3. Aerodr Ns Ac Cable (for Wired Connection)  Power Supply Cable For Continuous Power Workstation: Radiologic Technologist Workstation  Branded Desktop With Core I5 Processor, 4gb Ram, 1tb Ssd,  Viewing Software  One (1) Unit 1kva Ups One (1) Unit 60kva Avr For X-ray 1 Lot 3,564,000.00 4 Medical Waste Autoclave Machine Specifications:  Vertical Pressure Vessel And Shredder Made In Stainless Steel  Two Automatic Sealed Doors  Optional Automatic Loading  Loading From The Top Of The Machine. The Total Load Will Be Placed In The Upper Chamber  The Lower Chamber Is Made Of Perforated Stainless Steel And Equipped With Temperature Control In The Heart Of The Waste (temperature Sensor) And Automatic Rotary Drawer Opening Door For The Unloading Of Waste.  Locked Door And Completely Sealed For Air, Water And Particulate  Is Equipped With A System Of Separation Of Solid And Liquid Waste  Is Equipped With A Heat Recovery System For Pre-heating Of The Water Of The Steam Generator From The Exhaust Air Of The Machine  Is Equipped With An Odor Control System, Flash Tank  Noiseless < 75db, Vibration-free And Without Harmful Radiation For The Operator  Paddle Instrument To Automatically Feed The Shredder And Avoid Jamming  Does Not Require Any Consumables Or Any Complementary Equipment Like But Not Limited To; (external Shredder, Compactor, Conveyor). Features:  Dimensions (l X L X H), Cm 200 X120 X 212  Shipping Weight, Kg 635  Max Weight When Filled With Water, For A Special Hydraulic Test. Kg 780  Stress, Kg/cm² 0.1  Steam Pressure. Bars 8  Max Steam Flow, Kg/h (existing Steam Network) 35  Compressed Air. Bars 6-7  Electricity 3*380 V 50/60 Hz, Kw 3.2 – 5.0 Operating Feature:  Average Cycle Time, Minutes 30  Process Volume Capacity, Liters 100  Average Waste Density, Kg/m³ 100-150  Average Process Weight Capacity, Kg/cycle 10-15  Waste Volume Reduction 80%  Microbial Inactivation 108 Or 8 Log 10 Consumption / Cycle - Steam. Kg 6  Electricity. Kwh 0.55  Water. Liters 5 Boiler Specifications:  Dimensions (l X L X H), Cm 100 X 100 X 145  Shipping Weight, Kg 150  Max Weight When Filled With Water, For A Special Hydraulic Test. Kg 205  Maxi Steam Pressure. Bars 8.5  Working Steam Pressure Bars 7  Boiler Volume , L 55  Water Tank Volume ,l With Preheating 100  Electricity 380 V / 50 Hz /tri Phase+ Neutral , Kw 37. Installation Requirements:  External Steam Supply Or Separate Steam Generator With Heat Recovery System  Power Supply: 3-phase 380v/440v/480v 50-60hz  Tension 3x380v-400v 50hz / Puissance 3.2kw, Terminals Connections Are Located At The Bottom Of The Control Panel.  Dimension Of Panel Control: Width: 60 Cm, Depth: 25 Cm, Height: 80cm Connections:  Solenoid Valve Of The Flash Tank X3 (3&4) 2g0,5 Mm ² - 220 Vac  Thermostat Of The Flash Tank X3 ( 1&2) 2g0,5 Mm ² - 220 Vac Site Selection:  Area Size: 6 To 9 M²  Ceiling Height: 2.35 Meters  Room Ventilation: 2 Up To 3 Time The Volume Area.  Plan An Extraction Near The Machine  Room Temperature: 4 -38°c, (35-100°f) Earth Ground:  Stress By Foot De 0.1kg/cm² Water Requirements (flash Tank):  Water: Tank Connection 1/2’’, Dn15 Female  Quantity: 15 Liters Per Cycle 30 Liters Per Hour  Flow Rate: 1-2 M³ /hour  Pressure: 1- 4 Bars, (15 To 60 Psi)  Ph: 7 Sanitary Drain:  Draining Of The Machine To The Flash Tank: Connection 2’’/ Dn50 Male  Flow Rate: 1m³ /hour  Pressure: 0, 5 Bars, (8 Psi)  Discharge Temperature: 70-90 °c, (158-194°f) Draining Of The Flash Tank 1 ’’/ Dn25 Male:  Flow: 1m³ / Hour  Pressure: 0 Bars  Temperature: 30-70 °c, (86-158°f) Adjustable By A Thermostat Vent:  The Machine Requires A Vent For Releasing The Pressure Vessel To The Atmosphere.  The First Decompression V181 Is Connected To The Flash Tank, The Second One V1018 « Decompression Free » Can Be Extend Outside The Room. * The Same Dimension Pipe From The Machine To Outside, 1/2 ‘’. Decompression V181 To The Flash Tank: Connection 1/2’’/ Dn15 Male Decompression Free V1018: Connection ½’’/ Dn15 Male:  Pressure: 0, 5 Bars, (8psi)  Discharge Temperature: 80 °c, 176°f Maximum The Shredder:  Built-in Shredder In Stainless Steel, Special Alloy Knives  Shredder With 2 Shafts With Low-speed Rotative Knives (less Than 40rpm) With An Automatic Reverse In Case Of Jam  The 2 Shafts With Knives Have Different Speeds. The Sterilization:  Sterilization Temperature: 138°c In The Heart Of The Waste  Average Pressure: 3.5 Bar  Dual Controls Of Temperature With 2 Sensors, One Is Located In The Heart Of The Waste  Reduction 8log10 Bacillus Spores (or 10-8) Steam Supply:  Steam: Connection 1/2’’ Dn15 Female Flow Rate: 65 Kg /hour Pressure: 7-8 Bars, (100 To 120 Psi) Compressed Air Requirements:  Air: Connection On The Pneumatic Box 1 /4’’ Female Or Polyamide Pipe 6/8 Flow Rate: 9m³ /hour Pressure: 6-7 Bars, (90 To 100 Psi) The Treatment:  Volume Of Waste Treated, 100 Liters Of Biomedical Waste Per Cycle  Average Cycle Duration: 30 Minutes  All In One Automated Cycle From Loading To Unloading  No Intermediate Handling Of The Waste During The Treatment Cycle  The Shredder As Well As The Upper And Lower Chambers Are Fully Sterilized At Each Cycle  Waste Volume Reduction: 80%  Waste Weight Reduction Up To 30% According To The Nature Of The Waste  The System Renders The Waste Unreusable And Safe To Dispose Of As Ordinary Municipal Waste  Gravity Unloading Safety Data:  Is Equipped With An Interlock Mechanism  Data Report Generated In Hard-copy And Soft Copy On A Memory Card For Each Treatment Cycle And The Possibility Of Transfer To A Pc Via A Wired Connection  For Security Access, Data And Program Integrity Are Password Protected  The Cycle Is Fully Automated And Controlled By Plc And A “touch Screen” Interface  The Color “touch Screen” Is Multilingual (french, English And In The Language Of The Country  The System Features An Advanced, Interactive, And Operator-definable Interface Layout For Cycle’s Progress Display, Support, Configuration, Setup, Maintenance, Troubleshooting, Alarms And Step-by-step Diagnostics Assistance  Recorded Data Include Cycle Number, Treatment Step, Cycle Ok Status, And Treatment Parameters Such As Exposure Time, Chamber Temperature, Steam Pressure, Waste Temperature And The Sterilizing Value F0  Data Report Is Generated In Both Electronic And Hard-copy Formats  For Record Keeping, The Operating Results Of Essential Parameters Are Automatically Printed For Each Treatment Cycle.  Possibility Of Manual Recovery, Via A Key, Of Some Features Of The Machine (opening, Closing, Emptying…)  Jam Prevention Protocol To Avoid Blocking The Shredder  Self-diagnostic System With Alarm  Leakage System Control For Gaskets  Automatic Greasing System Of The Shredder Mechanical Seals  Remote Control Of The Machine Via A Secure Connection Using An Industrial Vpn Router (the Router Can Be Connected Directly To The Internet Box, Otherwise The Router Also Has A 4g Connection Allowing A Link To Be Established Via The Cellular Network). International Certificates:  Asme (the American Society Of Mechanical Engineers), Ce (european Directives)  Gosstandart (russia), Mhlw (japanese Ministry Of Health, Labor & Welfare)  Mlse (china)  Standards Iso 9001: 2015 & Iso 14001: 2015 Manufacturer References In The Field Of The Infectious Waste Treatment:  Minimum Of 350 Current References.  Minimum Of 10 Years Of Experience In The Field  Maintained A Sale Record Of 20 Machines Per Year In The Last 10 Years  Presence In At Least 40 Countries. Accessories: 1. Dry Type Step-up Transformer, 50kva  Capacity: 50kva 3 Phase Delta/wye  Primary: 220vac/230vac/400vac Delta Connection  Secondary: 380vac/400vac + Neutral  Phase: 3 Phase  Hertz: 60hz  Temp Rise: 150 Degree Centigrade @40 Degree Centigrade Ambient 2. For Circuit Breaker  Input For 50kva 220 Volts, Single Phase 125 Amp.  Output Of Step Up 75 Amp 3phase. 1 Lot 17,400,000.00 5 Emergency Cart Specifications:  Size: 750mm X 475mm X 930mm Cabinet Height  Abs Body  Abs Molded Base And Top Place  With 5 Drawers 2 Small Drawers Surface Height 80mm, Inside Size 424 X 375 X 68mm 2 Medium Drawers Surface Height 120mm, Inside Size 424 X 375 X 110mm 1 Big Drawer Surface Height 240mm, Inside Size 424 X 375 X 220mm  With 3 X 3 Separator Inside The Drawer  With 5mm Guard Rubber Bumper  With 4 Pvc Luxury Noiseless Caster, 2 With Break, Anti-static  Left Side: Defibrillator Platform, Hidden Adjustable Work Table, Stuff Basket  Right Side: Hidden Height Adjustable Iv Pole, 2l Sharp Box In Basket, 2 Dustbin  Back Side: Cpr Board, Hidden Adjustable Oxygen Cyinder Holder, 5 Meters Electrical Wires  1 Pc Stainless Steel Trashcan  1 Pc Abs Cardiac Board 4 Unit 155,232.00 6 Defibrillator With Monitor Key Features:  Compact 3-in-one Integrated Design: Monitoring (ecg) Manual Defib And Aed.  7” Tft Color Display.  Intelligent Li- Ion Battery Power Supply Supporting 2.5 Hours Monitoring, 100 Shocks/ 2 Hours Pacing.  50 Mm Integrated Thermal Recorder  Large And Vivid Display With 3 Waveforms Assures Easy Ecg Viewing.  Defibrillation, Synchronized Cardioversion And Aed With Biphasic Technology  Up To 360j Escalating Dose Energy To Maximize Defibrillation Success.  Powerful Power Capacity With Battery To Support Continuous Long Time Monitoring And Shocks During Transport Without External Power Supply.  Compact, Light Weighted Design Especially For Both Hospital And Clinics Application.  Ipp4 Water And Dust Proof Level Assures D3’s Reliable Performance In All Suitable Clinical Environments.  Diagnostic Quality Measurements And Monitoring Including 3/5 Lead Ecg.  Freezing Waveforms Reviewing Of Latest 12’secg Waveforms Ensures The Expansion Detection Of Abnormal Signal And 72 Hours Trend.  Centralized Settings Of Defibrillation And Monitoring In One Page, Easy To Set All Configuration At One Time.  Powerful Data Storage Including 100 Patients Profile, 1000 Events For Each Patient And 24h Consecutive Waveform Storage Satisfies Medical Professional For Case Analysis, Clinical Statistics And Paper Research Requirements.  Observable Data Color And Color Distinguishing Buttons Simplify Manual Defibrillation With Only 1-2-3 Steps.  Large Alarm Lamp Quickly Attracts Attention For Patient’s Situation Promptly To Improve Patients Care.  Paddle Operating Buttons Makes Shock Delivery Quick And Easy By Convenient Energy Selecting, Charging And Shocking Buttons.  Rotary Knob Is Very Convenient For Input And Onscreen Navigation By Simple Turning And Pressing.  Lead Selections Button Assures Quick Access For Optimal Ecg Waveform Appearance.  Multiplex Power Supply Ac/dc/12 Voltage Dc Input, Enables Machine Working Every Places. Standard Accessories:  Paddles - The External Paddles Quickly Converted From Adult To Pediatric By Removing The Outer Surface.  Pads - Adult And Pediatric Multifunction Defibrillators Pads.  3/5 Leads Ecg Cable & Leadwire  50 Mm Thermal Paper Recorder  Defib Gel  Power Cord 1 Unit 361,350.00 7 Transport Mechanical Ventilator Physical Specification:  Dimensions (hxwxd): 354 Mmx315 Mmx255 Mm (excluding The Trolley)  Weight: Approximately 10kg (excluding The Trolley) Display:  Screen: 12.1” Color Active Matrix Tft Touch Screen  Resolution (hxv): 1280x800 Pixels  Brightness: Adjustable Trolley:  Dimensions (hxwxd): 1039 Mmx528 Mmx544 Mm  Weight: Approximately 20 Kg Communication Interface:  Rs-232, Nurse Call Connector, Vga Connector, Usb Port, Ethernet Ventilation Specifications:  Patient Type: Adult, Pediatric, Neonate  Ventilation Mode: V-a/c (volume Assist/control) P-a/c (pressure Assist/control) V-simv (volume-synchronized Intermittent Mandatory Ventilation) P-simv (pressure-synchronized Intermittent Mandatory Ventilation) Duolevel (duo Level Ventilation) Cpap (continuous Positive Airway Pressure) Psv (pressure Support Ventilation) Vs (volume Support) Aprv (airway Pressure Release Ventilation) Prvc (pressure Regulated Volume Control) Prvc-simv (prvc-synchronized Intermittent Mandatory Ventilation) Amv (adaptive Minute Ventilation) Cprv (cardio-pulmonary Resuscitation Ventilation) Ncpap (nasal Continuous Positive Airway Pressure Ventilation) Niv (non-invasive Ventilation) Apnea Ventilation Controlled Parameters:  O₂%: 21 To 100 Vol.%  Tv (tidal Volume) Adult: 100 To 2000 Ml Pediatric: 20 To 300 Ml Neonate: 2 To 100 Ml  Mv%: 25% To 350%  F: Adult / Pediatric: 1 To 100 /min Neonate: 1 To 150 /min  Fsimv (ventilation Frequency In Simv Mode): 1 To 60 /min  I:e: 1:10 To 4:1  Tinsp: 0.10 To 10.00 S  Tslope: (time Of Pressure Rising): 0.00 To 2.00 S  Thigh: 0.10 To 30.00 S  Tlow: 0.20 To 30.00 S  Tpause: Off, 5% To 60%  Flow Pattern Square, 100% Decelerating, 50% Decelerating  ∆pinsp: 1 To 80 Cmh₂o  ∆psupp: 0 To 80 Cmh₂o  Phigh: 0 To 80 Cmh₂o  Plow: 0 To 50 Cmh₂o  Peep: 0 To 50 Cmh₂o  Flow Trigger: Off, Adult/pediatric: 0.5 To 20.0 L/min; Neonate: 0.1 To 5.0 L/min  Pressure Trigger: Off, -20.0 To -0.5 Cmh₂o  Exp% (expiration Termination Level): Auto, 1% To 85%  Neg.plimit: (cprv) -30 To 0 Cmh₂o Apnea Ventilation:  Tvapnea Adult: 100 To 2000 Ml Pediatric: 20 To 300 Ml Neonate: 2 To 100 Ml  ∆papnea: 1 To 80 Cmh₂o  Fapnea: Adult / Pediatric: 1 To 80 Bpm Neonate: 1 To 150 Bpm  Apnea Tinsp: 0.10 To 10.00 S Sigh:  Sigh Switch: On, Off  Interval: 20 S To 180 Min  Cycles Sigh: 1 To 20  ∆int. Peep: Off, 1 To 50 Cmh₂o Automatic Tube Resistance Compensation:  Tube Type: Et Tube, Trach Tube, Disable Atrc  Tube I.d. Adult: 5.0 To 12.0 Mm Pediatric: 2.5 To 8.0 Mm Neonate: 2.5 To 5.0 Mm  Compensate: 0 To 100 %  Expiration Compensation Switch: On, Off O₂ Therapy  O₂%: 21 To 100 Vol.%  Flow Adult/pediatric: 2 To 80 L/min Neonate : 2 To 20 L/min Automatic Leakage Compensation:  Maximum Leakage Compensation Flow Adult: 65l/min Pediatric: 45l/min Neonate: 15l/min Intellicycle  Applicable Patient Type: Adult / Pediatric  Automatically Adjust Parameters: Trigger, Tslope, Exp%  Intellicycle Switch: On, Off Monitored Parameters:  Airway Pressure Range: Ppeak, Pplat, Pmean (range -20 To 120 Cmh₂o) Peep (range 0 To 120 Cmh₂o)  Tidal Volume Range: Tvi, Tve, Tve Spn (range 0 To 4000 Ml)  Frequency Range: Ftotal, Fmand, Fspn (range 0 To 200 /min)  Minute Volume Range: Mvi, Mve, Mvspn, Mvleak (range Adult/pediatric: 0 To 100 L/min Neonate: 0 To 30 L/min)  Leak%: 0 To 100%  Resistance: Rinsp, Rexp (range 0 To 600 Cmh₂o/l/s)  Compliance: Cstat, Cdyn (range 0 To 300 Ml/cmh₂o)  Inspired Oxygen (fio₂): 15 To 100 Vol.%  Rsbi: 0 To 9999 1/(min*l)  Wob: 0 To 100 J/min  P0.1: -20 To 0 Cmh₂o  Nif: -45 To 0 Cmh₂o  Peepi: 0 To 80 Cmh₂o  Rcexp: 0 To 10 S  Tve/ibw: 0 To 50 Ml/kg  I:e: 100:1 To1:150  Tinsp: 0.00 To 60.00s  Waveforms: Airway Pressure-time, Flow-time, Volume-time, Co₂-time , Pleth-time  Loops Paw-volume, Flow-volume, Paw-flow, Volume-co₂ Alarm Settings:  Tidal Volume: High Neo: Off, 3 To 200 Ml Ped: Off, 25 To 600 Ml Adu: Off,110 To 4000 Ml Low Neo: Off, 1 To 200 Ml Ped: Off, 10 To 600 Ml Adu: Off, 50 To 4000 Ml  Minute Volume High Neo: 0.02 To 30.0 L/min(can Be Set To Off In Ncpap) Ped: 0.2 To 60.0 L/min Adu: 0.2 To 100.0 L/min Low Neo: 0.01 To 15 L/min Ped: 0.1 To 30.0 L/min Adu: 0.1 To 50.0 L/min(can Be Set To Off In Niv)  Airway Pressure: High 10 To 85 Cmh₂o  Frequency: High Off, 1 To 160 /min  Inspired Oxygen (fio₂): High Auto, Fio₂ Exceeds The Alarm Limit For At Leastn30 S, Internal Alarm Limit: Set Value+max (7 Vol.% Or Set Value X10% ) Or 100 Vol.%, Whichever Is Lower. Low Auto, Fio₂ Lower Than The Alarm Limit For At Least 30 S, Internal Alarm Limit: Setvalue-max (7 Vol.% Or Set Valuex10%) Or 18%, Whichever Is Greater.  Apnea Alarm Time Low 5 To 60 S (can Be Set To Off In Ncpap) Trend:  Type: Tabular, Graphic  Length: 72 Hours  Content: Monitor Parameters, Setting Parameters (setting Ventilation Mode And Parameters) Log:  Type: Alarm, Operation  Max Number: 5000 Ventilator Components:  O₂ Sensor  Type: Calvanic Fuel Cell  Response Time: < 15 S Neonatal Flow Sensor:  Flow Range: 0.2 To 30 L/min  Dead Space: <0.75 Ml  Resistance: 0.9 Cmh₂o@10l/min Sidestream Co₂ Module:  Displayed Numeric: Etco₂  Measurement Range: 0 To 99 Mmhg  Resolution: 1 Mmhg  Waveforms: Co₂-time  Etco₂ High Alarm Limit: 2 To 99 Mmhg  Etco₂ Low Alarm Limit: 0 To 97 Mmhg Mainstream Co₂ Module:  Displayed Numerics: Etco₂, Veco₂, Vico₂, Vtalv, Vdaw, Vdaw/tve, Slopeco₂, Vco₂  Measurement Range: 0 To 150 Mmhg  Resolution: 1 Mmhg  Waveforms / Loop: Co₂ - Time, Volume - Co₂  System Response Time: < 2.0 S  Etco₂ High Alarm Limit: 2 To 150 Mmhg  Etco₂ Low Alarm Limit: 0 To 148 Mmhg Spo₂ Module:  Displayed Numeric: Spo₂, Pr, Pi  Spo₂ Measurement Range: 0 To 100 %  Pr Measurement Range: 20 To 254 1/min  Pi Measurement Range: 0.05 To 20 %  Waveform: Pleth  Spo₂ High Alarm Limit: 2 To 100 %  Spo₂ Low Alarm Limit: 0 To 98 %  Spo₂ Desat Alarm Limit: 0 To 98 %  Pr High Alarm Limit: 17 To 300 1/min  Pr Low Alarm Limit: 15 To 298 1/min Operation Data:  Environmental Specifications  Temperature: 5 To 40°c(operating); -20 To 60°c(storage)  Relative Humidity: 10 To 95 % (operating); 10 To 95 % (storage)  Barometric Pressure: 62 To 106 Kpa (operating); 50 To 106 Kpa (storage) Gas Supply:  Gas Type: O₂  Pipe Connector: Nist, Diss  Gas Supply Pressure: 0.28 To 0.6mpa  Peak Flow In Case Of Single Supply Gas: ≥ 210 L/min (btps)* Air Supply (blower):  Maximum Output Flow: ≥ 210 L/min (btps)*  Maximum Output Pressure: ≥ 80 Cmh₂o  Maintenance Interval 20,000 Hours Power And Battery Backup:  External Ac Power Supply Power Input Voltage: 100 To 240 V Power Input Frequency: 50/60 Hz Power Input Current: 2.7 To 1.1 A Fuse: T3.15 Ah/250 V  External Dc Power Supply Power Input Voltage: 12 V Power Input Current: 15 A  Internal Battery Number Of Batteries: One Or Two Battery Type: Build-in Lithium-ion Battery, 14.8 Vdc, 5800 Mah Battery Run Time: 180 Min (powered By One New Fully Charged Battery In Standard Working Condition)* 360 Min (powered By Two New Fully Charged Battery In Standard Working Condition) Special Functions And Procedures:  Sigh  100% O₂  Suction  Nebulization  Manual Breath  Inspiratory Hold  Expiratory Hold  Peepi  P0.1  Nif  Pv-tool  Pulmosight  Lung Recruitment Tool (si) 1 Unit 1,633,500.00 8 Infusion Pump Physical Specification:  Weight: < 2.5kg  Size: 245 X 174 X 87 Mm  Screen: 3.5-inch Tft Color Lcd, 480 X 272 Pixels  Brightness: 1-8 Levels, Adjustable  Display: Infusion Rate, Vtbi, Pressure Limit & Status, Drug Name, Remaining Time, Alarm Status, Total Volume, Battery Status, Brand Of Iv Administration Set Parameters Specification:  Accuracy: ≤ ±5%  Mode: Rate Mode, Time Mode, Body Weight Mode, Ramp Up/down Mode, Sequential Mode, Micro-infusion Mode, Loading Dose Mode  Flow Rate: 0.1 - 2000ml/h  Increment: 0.01ml(0.1-99.99ml/h); 0.1ml(100-999.9ml/h); 1ml(1000-2000ml/h)  Preset Volume(vtbi): 0.10 – 9999.99ml (increment: 0.01ml)  Preset Time:00:00:01 – 99:59:59, Adjustable  Accumulated Volume 0-9999.99 Ml  Kvo: 0.1-5.0ml/h Adjustable, Step 0.1ml/h, Default Is 1.0ml/h  Purge Rate: 0.10-2000ml/h  Bolus Rate: 0.1-2000ml/h (automatic Or Manual)  Occlusion Detection: 12 Levels Selectable: 75-975mmhg, Default Is 450mmhg; 4 Units Of Pressure Selectable: Mmhg/kpa/bar/psi, Default Is Mmhg  Anti-bolus: Unexpected Bolus Reduced When The Occlusion Occurs  Dose Rate Units: Ng/kg/min, Ng/kg/h,ug/kg/min, Ug/kg/h,ug/kg/24h, Mg/kg/min, Mg/kg/h, Mg/kg/24h,g/kg/min, G/kg/h, Mu/kg/min, Mu/kg/h, U/kg/min, U/kg/h, U/kg/24h, Ku/kg/h, Eu/kg/h, Mmol/kg/h, Mol/kg/h, Kcal/kg/h, Kcal/kg/24h, Meq/kg/min, Meq/kg/h  Air Bubbles Detection 6 Levels Selectable: 20/50/100/250/500/800μl, Accumulate Air: 0.1-4ml/h  Auto-lock Time: 1 - 5 Minutes Selectable; On/off Switchable  Drug Library: Up To 2000 Drugs; On/off Switchable  History Log: Up To 2000 Records  Volume Collection: Available In 4 Methods: 24h Total, Current Total, Period, Timing  Dose Error Reduction: Available; Definition Of Dose Limits;  System (ders): Automatic Alarms When Reaching Dose Limits Iv Administration Sets:  Compatibility: Diameter Range From 3.5 To 4.5mm While Thickness Is Between 0.8 And 1.2mm Alarms:  Type: Audible And Visual Alarm  3 Levels: High: Downstream Occlusion / Accumulated Air / Air In Ling / No ࡰower / Vtbi Com⁰lete / Kv Fiၮɩshed#? Doɯr Ope~ed/systemġ Medium: Abnormal#system/ 3tandby!timer Expired Low+ġreminder/ဠloŷ Cattery/ No Battery Inserted/ Time Nearꀢenၤ/ Vtji Near Ccccdone  Nů Ac Půwer  Skund Volume: 1ĭ8 Levdls!relectablf, Defaul| ቩs Levၥl 4•  Remmnder〺 1-5 Miîŵues Selectable; On/off ࡳwitchable Bat|eɲy:  Operat⁩ng Ti}e: ≅ 9 Iours At 25mŭ/h  Ńharging Time: ≤ ̶ Hoqrs To ɶull0capaity Inၴgɲface›  Rs233; Nursၥ Call Connecvor※&⁄⁃ ၡѥapter Őower Swűply:voltၡge 100-040 V~†; Frequen⁣y 5԰/60hz; Current 0.4-0.14a Work Environment:  Temperature: 5-40ºc For Operating; -20-60 ºc For Storage  Relative Humidity: 15-95% For Operating; 10-95% For Storage  Atmosphere Pressure 57-106 Kpa For Operating; 50-106 Kpa For Storage  Level Of Resistance To Water And Dust: Ip23 8 Unit 712,800.00 Note:  The Equipment Should Come With A Two-year Warranty, Preventive And Corrective Maintenance.  Bidders Should Attach Their Own Brochure For More Information About The Products And Services.
Closing Date14 Apr 2025
Tender AmountPHP 28.7 Million (USD 501.7 K)
1691-1700 of 1691 archived Tenders