Tenders of Dept Of The Air Force Usa
Tenders of Dept Of The Air Force Usa
DEPT OF THE AIR FORCE USA Tender
Automobiles and Auto Parts
United States
Nsn:1620-00-264-0750le
noun:cylinder And Piston
part #:7227216-10
Closing Date16 Nov 2026
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Electrical Goods and Equipments...+1Electrical and Electronics
Corrigendum : Closing Date Modified
United States
Update 21 Jan 2025: Amendment- Revision To Requirement Specifications
in Order To Ensure Accuracy And Fairness In The Evaluation Process, We Have Revisited The Original Unit Specifications And Determined That Further Clarification Was Necessary. To Provide All Contractors With An Equal Opportunity To Compete, We Are Issuing An Update To The Requirement Specifications. Please Review The Revised Details Below, Which Supersede The Original Specifications And Will Serve As The Basis For Evaluation Of All Offers.
offer Due Date Extended: 24 Jan 2025 @ 1:00 Pm Est
______________________________________________
general Statement:
this Is A Combined Synopsis/solicitation For Commercial Items Issued By The 23d Contracting Squadron, Moody Afb, Georgia. This Announcement Constitutes The Only Solicitation Being Issued For The Requirement Described Herein.
the Moody Afb Refrigerator And Freezer Combination Unit Located At 4251 George St, Bldg. 901, Moody Afb, Ga 31699 Requires Replacement. 23d Fss Requires Full Replacement Of The Current Refrigerator And Freezer Combination Unit. All Existing Equipment To Include Current Walk-in Box Unit And Condenser Units Require Replacement And Updated To Current Codes. The Removal And Disposal Of Old Unit And Condenser Units.
requirements For The Refrigeration/freezer Unit:
- 2 Compartment Walk-in Refrigerator And Freezer Unit 11'w X 29'l X 7'7”h
- Walk-in Cooler Refrigeration Unit 115v/230v 1ph
- Walk-in Freezer Refrigeration Unit 230v/230v 1ph
- Shipping Of All Items/supplies
- Installation Of All Components
- Blueprint/drawing Of Unit To Verify Dimensions, Used To Assist In Technical Specification Determination
- Sprinkler System Removal And Installation
- Satellite Temporary Removal And Reinstall
- Demolition Of Existing Equipment And Removal From Site
- All Equipment Rentals Relevant To Installation Process
- Include System Start-up And On-site Training
- All Equipment Required To Complete The Walk-in Refrigerator/freezer Unit Project In Its Entirety Shall Be Supplied By The Contractor
- Existing Concrete Pad To Be Re-used
- Standard 1-year Warranty
- Project Needs To Be Completed By End Of March 2025
salient Characteristics:
- The Walk-in Unit Will Have A Compartment Size Ratio Of 2:1, With Two-thirds Of The Space Allocated To Refrigeration And One-third To Freezing, To Accommodate The Customer's Need For More Refrigerator Space.
- Size Of Freezer Minimum 11' To Max 12' Side To Side
- The Unit Will Be Floor-integrated, Providing A Seamless Installation.
- The Doors Will Be Hinged On The Right Side And Will Open From The Left, Allowing For Easy Access And Operation.
hours Permitted To Work
- Monday To Friday 8:00 Am To 5:00pm
- Saturday And Sundays With Prior Approval From Facility Manager With Minimum 24 Hours' Notice In Writing.
important: To Ensure Consideration Of Your Quote
please Note That The Following Documents Are Mandatory And Must Be Included With Your Quote Submission. Failure To Provide These Documents May Result In Your Submission Being Excluded From Technical Evaluation And Consideration For This Requirement. It Is Essential That You Include All Required Documents To Ensure That Your Quote Can Be Properly Evaluated And Considered.
- Statement Of Work
- Technical Specification Of Unit (blueprint/drawing)
*expired* Site Visit: A Site Visit Will Be Held On Wednesday December 18 2024 At 2:00 Pm Est. While Attendance Is Not Mandatory, It Is Highly Recommended. Vendors Are Encouraged To Inspect The Site In Order To Satisfy Themselves Regarding All General And Local Conditions That May Affect The Cost Of Contract Performance To The Extent That Information Is Reasonably Obtainable. In No Event Shall Failure To Inspect The Site Constitute Grounds For A Claim After Contract Award. Please Arrive At The Moody Air Force Base Visitor's Center No Later Than 1:30 Pm Est For Check-in (required For All Contractors Prior To Entering The Base) To Ensure On Time Arrival For The Site Visit.
notice To Offeror(s)/supplier(s): The Government Reserves The Right To Cancel This Solicitation, Either Before Or After The Closing Date. In The Event The Government Cancels This Solicitation, The Government Has No Obligation To Reimburse An Offeror For Any Costs.
Closing Soon24 Jan 2025
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Others...+2Civil And Construction, Civil Works Others
United States
The Purpose Of This Amendment Is To Extend The Close Date.
first: Extend The Closing Date To 12 February 2025
second: All The Other Terms And Conditions Remain In Full Force And Effect.
Closing Date12 Feb 2025
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Civil And Construction...+1Civil Works Others
United States
Nsn: 2840-01-308-4469nz
noun: Liner, Augmentor Com
top Drawing: 4078304
edl Revision & Date: 24 / 02 Mar 2021
mdc Code: Wab
im Name: Sneed, Toomy J.
Closing Date11 Apr 2025
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Others
United States
Nsn:1650012069074le
noun:swivel Joint,hydrau
p/n:1881-113a01
Closing Date28 Apr 2026
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Aerospace and Defence
Corrigendum : Closing Date Modified
United States
Commercial Solutions Opening - Kadena Air Base, Japan
Closing Date2 Jan 2029
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Healthcare and Medicine
United States
This Requirement Is For The Hyperlite 1 Portable Hyperbaric Chamber Built To Military Specification To Include All Items Necessary For No Downtime Maintenance Pack, 5-year Preventative Maintenance Plan, Operations Training, Patient Care Training, And Service/maintenance Training. Chambers Must Have The "safe To Fly" Certification Testing From Usafrl And Be Man-portable. Additionally, Chambers Must Be Able To Run United States Navy Dive Table 6 Treatments During Land, Air, And Sea Transportation.
based On Market Research, This Is The Only Known Soft Sided, Man-portable Hyperbaric Chamber That Is Capable Of Meeting The Identified Requirements. Please See The Applicable Request For Quote Fa520525qb004 For More Detailed Requirements.any Questions Regarding This Notice Must Be Submitted In Writing Via Email To 2d Lt Hunter Closs At Hunter.closs.2@us.af.mil And Tsgt Joshue Madilar At Joshue.madilar.1@us.af.mil No Later Than 24 Jan 25 At 1630 (eastern Standard Time).
Closing Soon24 Jan 2025
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Electrical Goods and Equipments...+1Electrical and Electronics
United States
Nsns:
1377-01-318-5643es
1377-01-318-5644es
1377-01-318-5645es
1377-01-318-5646es
p/n:daa3294p404-201
noun:charge,shaped
Closing Date31 Aug 2026
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Machinery and Tools
United States
Nsn:5306-01-642-8613le
noun: Bolt, Machine
p/n: 201416427-01
Closing Date17 Mar 2027
Tender AmountRefer Documents
DEPT OF THE AIR FORCE USA Tender
Machinery and Tools
United States
1630013383800xwrotor Assembly,disc
Closing Date27 Jul 2026
Tender AmountRefer Documents
51-60 of 820 active Tenders