Call Center Tenders
Call Center Tenders
Municipality Of Los Ba os, Laguna Tender
Others
Philippines
Closing Date9 Oct 2024
Tender AmountPHP 850 K (USD 15 K)
Details: Description I. Main Unit (1 Unit) 1 Lot Analog Telephone Fxs Ports: 1 Rjii Port Pstn Line Fxo Ports: 1 Rjii Port Network Interfaces Three Self-adaptive Gigabit Ports (switched, Routed Or Dual Mode) With Poe+ Nat Router Yes (supports Router Mode And Switch Mode) Peripheral Ports 1*usb 3.0, Sd Card Interface Led Indicators None Lcd Display 320x240 Color Lcd With Touchscreen For Shortcut Keys And Scroll Bar Voice-over-packet Capabilities Lec With Nlp Packetized Voice Protocol Unit, 128ms-tail-length Carrier Grade Line Echo Cancellation, Dynamic Jitter Buffer, Modem Detection & Auto-switch To G.711 Neteq,fec 2.0 Jitter Resilience Up To 50% Audio Packet Loss Voice And Fax Codecs:opus, G.711 A-law/u-law, G.722, G722.1 G722.1c, G.723.1 5.3k/6.3k, G.726-32, G.729a/b, Ilbc, Gsm; T.38 Video Codecs: H.264, H.263, H263+, Vp8 Qos:layer 2 Qos (802.1q, 802.1p) And Layer 3 (tos, Diffserv, Mpls) Qos Api:full Api Available For Third-party Platform And Application Integration Telephony Operating System: Based On Asterisk Version 16 Dtmf Methods: S In-band Audio, Rfc2833, And Sip Info Provisioning Protocol & Plug-and-play: Mass Provisioning Using Aes Encrypted Xml Configuration File, Auto-discovery & Auto-provisioning Of Grandstream Ip Endpoints Via Zeroconfig (dhcp Option 66 Multicast Sip Subscribe Mdns), Eventlist Between Local And Remote Trunk Network Protocols: Sip, Tcp/udp/ip, Rtp/rtcp, Iax, Icmp, Arp, Dns, Ddns, Dhcp, Ntp, Tftp, Ssh, Http/https, Pppoe, Stun, Srtp, Tls, Ldap, Hdlc, Hdlc-eth, Ppp, Frame Relay (pending), Ipv6, Openvpn Disconnect Methods: Busy/congestion/howl Tone, Polarity Reversal, Hook Flash Timing, Loop Current Disconnect Media Encryption: Srtp, Tls, Https, Ssh, 802.1x Universal Power Supply: Input: 100 ~ 240vac, 50/60hz; Output: Dc 12v, 1.5a Dimensions: 270mm(l) X 175mm(w) X 36mm(h) Weight: Unit Weight: 715g; Package Weight: 1211g Temperature & Humidity: Operating: 32 - 113ºf / 0 ~ 45ºc, Humidity 10 - 90% (non-condensing) Storage: 14 - 140ºf / -10 ~ 60ºc, Humidity 10 - 90% (non-condensing) Mounting:wall Mount & Desktop Caller Id:bellcore/telcordia, Etsi-fsk, Etsi-dtmf, Sin 227 – Bt, Ntt Polarity Reversal/wink: Yes, With Enable/disable Option Upon Call Establishment And Termination Call Center: Multiple Configurable Call Queues, Automatic Call Distribution (acd) Based On Agent Skills/availability/ Work-load, In-queue Announcement Customizable Auto Attendant: Up To 5 Layers Of Ivr (interactive Voice Response) In Multiple Languages Maximum Call Capacity:users: 500 Concurrent Calls (g.711): 75 Max Concurrent Srtp Calls (g.711): 50 Maximum Attendees Of Conference Bridges: 4 Video Conference Rooms And Up To 20 Parties With 1080p, Assuming 4 Video Feeds + 1 Screen Sharing (h.264 & Opus) Voice Conference: Up To 75 Parties (g.711) Wave App:free; Available For Desktop (windows 10+, Mac Os 10+), Web (firefox And Chrome Browsers) And Mobile (android & Ios), Allows Users To Join Ucmhosted Meetings/conferences, Communicate With Other Users/solutions And Make/receive Calls Using Sip Accounts Registered To A Ucm6300 Series Ip Pbx Call Features: Call Park, Call Forward, Call Transfer, Call Waiting, Caller Id, Call Record, Call History, Ringtone, Ivr, Music On Hold, Call Routes, Did, Dod, Dnd, Disa, Ring Group, Ring Simultaneously, Time Schedule, Pin Groups, Call Queue, Pickup Group, Paging/intercom, Voicemail, Call Wakeup, Sca, Blf, Voicemail To Email, Fax To Email, Speed Dial, Call Back, Dial By Name, Emergency Call, Call Follow Me, Blacklist/whitelist, Voice Conference, Video Conference, Eventlist, Feature Codes, Busy Camp-on/ Call Completion, Voice Control, Post-meeting Reports, Virtual Fax Sending/receiving, Email To Fax Fxo Gateway (1 Unit) Network Interfaces 10m/100mbps, Dual Rj45 Ports Led Indicators Power, Network And Line Leds Voice-over-packet Capabilities G.168 Compiant Echo Cancelation, Dynamic Jitter Buffer, Moderm Detection & Auto-switch G.711 Ptsn Fail-over Life Line Ptsn Failover On Power Failure Voice Compression G.711, G.723, G.726 (40/32/24/16), G.729a/b/e, G.728, Ilbc Dhcp Client Yes, Switched Mode Or Pppoe Fax Over Ip T.38 Compliant Group 3 Fax Relay Up To 14.4kpbs & Auto-switch To G.711 For Fax Pass-through Qos Diffserve, Tos, 802.1p/q Vlan Tagging Ip Transport Rtp/rtcp Dtmf Method Flexible Dtmf Transmission Method, User Interface Of In-audio, Rfc2833, And/or Sip Info Ip Signaling Sip (rfc 3261) Ip Phone For Operator (1 Unit) Protocols/standards Sip Rfc3261, Tcp/ip/udp, Rtp/rtcp, Http/https, Arp, Icmp, Dns(a Record, Srv, Naptr), Dhcp, Pppoe, Telnet, Tftp, Ntp, Stun, Simple, Lldp, Ldap, Tr-069, 802.1x, Tls, Srtp, Ipv6 Network Interfaces Dual Switched Auto-sensing 10/100/1000 Mbps Gigabit Ethernet Ports With Integrated Poe Graphic Display 2.8 Inch (320x240) Tft Color Lc Wi-fi Yes, Integrated Dual-band Wi-fi 802.11 A/b/g/n/ac (2.4ghz & 5ghz) Bluetooth Yes, Integrated Feature Keys 8 Line Keys With Up To 4 Sip Accounts, 4 Xml Programmable Context Sensitive Softkeys, 5 Navigation/menu Keys, 9 Dedicated Function Keys For: Message(with Led Indicator), Transfer, Hold, Headset, Mute, Send/redial, Speakerphone, Vol+, Vol Auxiliary Port Rj9 Headset Jack Allowing Ehs With Plantronics Headsets, Usb To Support Grandstream’s Guv Series Headsets And Other Usb Headsets Telephony Features Hold, Transfer, Forward, 5-way Conference, Call Park, Call Pickup, Shared-callappearance(sca)/bridged-line-appearance(bla), Downloadable Phonebook(xml, Ldap, Up To 2000 Items), Call Waiting, Call Log(up To 2000 Records), Xml Customization Of Screen, Off-hook Auto Dial, Auto Answer, Click-to-dial, Flexible Dial Plan, Hot-desking, Personalized Music Ringtones And Music On Hold, Server Redundancy And Fail-over Hd Audio Yes, Hd Handset And Speakerphone With Support For Wideband Audio, And Dual Microphone. Extension Module Yes, Gbx20 Base Stand: Yes, 2 Angle Positions Available, Wall Mountable (wall Mount *sold Separately) Security: User And Administrator Level Passwords, Md5 And Md5-sess Based Authentication, 256-bit Aes Encrypted Configuration File, Srtp, Tls, 802.1x Media Access Control, Secure Boot Power & Green Energy Efficiency: Universal Power Adapter Included: Input: 100-240v ; Output: +12v, 1a ; Integrated Power-over-ethernet (802.3af) Max Power Consumption 9.5w (power Adapter) Or 10.8w (poe) Physical: Dimension: 220mmx 210mmx 82mm Unit Weight: 880g ; Package Weight:1260g Lcd Extension For Operator (1 Unit) Lines 20 Per Page (each Module Contain 2 Pages,for Up To 40 Lines Per Module Up To 160 With 4 Daisy Channel Modules Graphic Display 4.3 Inch (480x272) Tft Color Lcd Physical Dimension: 210mm*124mm*33.5mm; Unit Weight: 360g; Package Weight:700g Temperature And Humidity Operation: 0°c To 40°c Storage: -10°c To 60°c Humidity: 10% To 90% Non-condensing Phones Per Office (65 Units) Protocols/standards Sip Rfc3261, Tcp/ip/udp, Rtp/rtcp, Rtcp-xr, Http/https, Arp, Icmp, Dns(a Record, Srv, Naptr), Dhcp, Pppoe, Ssh, Tftp, Ntp, Stun, Simple, Lldp, Ldap, Tr069, Snmp, 802.1x, Tls, Srtp, Ipv6 Network Interfaces Dual Switched Auto-negotiation 10/100 Mbps Ethernet Ports, Integrated Poe Wi-fi Single Frequency, 2.4 Ghz, 802.11 B/g/n/ax (2.4g Only Graphic Display 132 X 48 (2.41’’) Lcd Display Feature Keys 4 Xml Programmable Context Sensitive Soft Keys, 5 (navigation, Menu) Keys. 8 Dedicated Function Keys For: Message(with Led Indicator), Transfer,headset, Mute, Send/redial, Speakerphone, Vol+, Vol Telephony Features Hold, Transfer, Forward, 5-way Conference, Call Park, Call Pickup, Downloadable Phonebook(xml, Ldap, Up To 2000 Items), Call Waiting, Call Log(up To 800 Records), Off-hook Auto Dial, Auto Answer, Click-to-dial, Flexible Dial Plan, Hot-desking, Personalized Music Ringtones And Music On Hold, Server Redundancy And Fail-over Qos Layer 2 Qos (802.1q, 802.1p) And Layer 3 (tos, Diffserv, Mpls) Qos Security User And Administrator Level Passwords, Md5 And Md5-sess Based Authentication, 256-bit Aes Encrypted Configuration File, Srtp, Tls, 802.1x Media Access Control, Secure Boot Power & Green Energy Efficiency Universal Power Supply Input 100-240vac 50-60hz; Output +5vdc, 600ma;poe: Ieee802.3af Class 1, 3.84w; Ieee802.3az (eee) Physical Dimension: 208mm (l) X 180mm (w) X 63.4mm (h) (with Handset) Unit Weight: 650g (651g For Grp2601w); Package Weight: 810g Router Dual Band (1 Unit) Standards Wifi 6 Ieee 802.11 Ax/ac/n/a 5ghz Ieee 802.11 Ax/n/b/g 2.4ghz Wfi Capacity Dual Band Allocate Devices To Different Bands For Optimal Performance Ofdma Simultaneously Communicates With Multiple Wi-fi 6 Clients Airtime Fairness Improves Network Efficency By Limiting Excessive Occupation Dfs Access An Extra Band Due To Reduce Congestion 4 Streams Connect Your Devices To More Bandwitdth Working Modes Router Mode Access Point Mode Processor 1x Gigabit Wan Port 4x Gigabit Lan Port Buttons Wi-fi/wps Button Power On/off Button Reset Button Dimension (wxdxh) 10.2x5.3x1.6in (260.2 X135 X 41.6mm) Network Switch Poe (3 Unit) Standards And Protocols Ieee 802.3i, Ieee 16× Gigabit Poe+ Rj45 Ports, 2× Gigabit Non-poe Rj45 Ports, And 2× Combo Gigabit Sfp Slots Network Media 10base -t: Utp Category 3,4,5 Cable (maximun 100m) 100base-tx/1000 Fan Quality Fanless Power Supply 100-240vac, 50/60 Power Consumption Maximum: 9.26w Dimensions (wxdxh) 11.6x7.1x1.7 In Switching Capacity 32gbps Packet Forwarding Rate 23.8mbps Mac Address Table 8k Jumbo Frame 10kb Green Technology Yes Transfer Method Store-and-forward Network Switch (1 Unit) Standards And Protocols Ieee 802.3i, Ieee 802.3u, Ieee 802.3ab, Ieee 802.3x Interface 16 10/100/1000mbps Rj45 Ports (auto Negotiation/auto Mdi/mdix) Network Media 100base-tx/1000base-t: Utp Category 5, 5e Or Above Cable (maximum 100m) Fan Quantity Fanless Physical Security Lock Power Supply 100-240vac, 50/60hz Power Consumption Maximum: 9.26w (220v/50hz) Dimensions (w X D X H) 11.6 X 7.1 X 1.7 In. (294 X 180 X 44 Mm) Max Power Consumption 9.95w (220v/50hz) Switching Capacity 32gbps Utp Cable (12 Boxes) Paired - Datatwist Category 5e ( Blue ) 4 Pair Utp 200mhz Category 5e Vertical Tray Rated 24 Awg Solid Bare Copper - Polyolefin Insulation - Pvc Jacket - Rip Cord Rj45 Io Port For Cat6 (66 Pcs) Bill Of Materials (moldings, Pvc Pipes, Sealants, Connectors) Inclusion: Labor, Installation Training And Commisioning 1 Year Free Service And Warranty **** Nothing Follows****
Municipality Of Los Ba os, Laguna Tender
Telecommunication Services
Philippines
Closing Date21 Nov 2024
Tender AmountPHP 850 K (USD 14.4 K)
Details: Description I. Main Unit (1 Unit) 1 Lot Analog Telephone Fxs Ports: 1 Rjii Port Pstn Line Fxo Ports: 1 Rjii Port Network Interfaces Three Self-adaptive Gigabit Ports (switched, Routed Or Dual Mode) With Poe+ Nat Router Yes (supports Router Mode And Switch Mode) Peripheral Ports 1*usb 3.0, Sd Card Interface Led Indicators None Lcd Display 320x240 Color Lcd With Touchscreen For Shortcut Keys And Scroll Bar Voice-over-packet Capabilities Lec With Nlp Packetized Voice Protocol Unit, 128ms-tail-length Carrier Grade Line Echo Cancellation, Dynamic Jitter Buffer, Modem Detection & Auto-switch To G.711 Neteq,fec 2.0 Jitter Resilience Up To 50% Audio Packet Loss Voice And Fax Codecs:opus, G.711 A-law/u-law, G.722, G722.1 G722.1c, G.723.1 5.3k/6.3k, G.726-32, G.729a/b, Ilbc, Gsm; T.38 Video Codecs: H.264, H.263, H263+, Vp8 Qos:layer 2 Qos (802.1q, 802.1p) And Layer 3 (tos, Diffserv, Mpls) Qos Api:full Api Available For Third-party Platform And Application Integration Telephony Operating System: Based On Asterisk Version 16 Dtmf Methods: S In-band Audio, Rfc2833, And Sip Info Provisioning Protocol & Plug-and-play: Mass Provisioning Using Aes Encrypted Xml Configuration File, Auto-discovery & Auto-provisioning Of Grandstream Ip Endpoints Via Zeroconfig (dhcp Option 66 Multicast Sip Subscribe Mdns), Eventlist Between Local And Remote Trunk Network Protocols: Sip, Tcp/udp/ip, Rtp/rtcp, Iax, Icmp, Arp, Dns, Ddns, Dhcp, Ntp, Tftp, Ssh, Http/https, Pppoe, Stun, Srtp, Tls, Ldap, Hdlc, Hdlc-eth, Ppp, Frame Relay (pending), Ipv6, Openvpn Disconnect Methods: Busy/congestion/howl Tone, Polarity Reversal, Hook Flash Timing, Loop Current Disconnect Media Encryption: Srtp, Tls, Https, Ssh, 802.1x Universal Power Supply: Input: 100 ~ 240vac, 50/60hz; Output: Dc 12v, 1.5a Dimensions: 270mm(l) X 175mm(w) X 36mm(h) Weight: Unit Weight: 715g; Package Weight: 1211g Temperature & Humidity: Operating: 32 - 113ºf / 0 ~ 45ºc, Humidity 10 - 90% (non-condensing) Storage: 14 - 140ºf / -10 ~ 60ºc, Humidity 10 - 90% (non-condensing) Mounting:wall Mount & Desktop Caller Id:bellcore/telcordia, Etsi-fsk, Etsi-dtmf, Sin 227 – Bt, Ntt Polarity Reversal/wink: Yes, With Enable/disable Option Upon Call Establishment And Termination Call Center: Multiple Configurable Call Queues, Automatic Call Distribution (acd) Based On Agent Skills/availability/ Work-load, In-queue Announcement Customizable Auto Attendant: Up To 5 Layers Of Ivr (interactive Voice Response) In Multiple Languages Maximum Call Capacity:users: 500 Concurrent Calls (g.711): 75 Max Concurrent Srtp Calls (g.711): 50 Maximum Attendees Of Conference Bridges: 4 Video Conference Rooms And Up To 20 Parties With 1080p, Assuming 4 Video Feeds + 1 Screen Sharing (h.264 & Opus) Voice Conference: Up To 75 Parties (g.711) Wave App:free; Available For Desktop (windows 10+, Mac Os 10+), Web (firefox And Chrome Browsers) And Mobile (android & Ios), Allows Users To Join Ucmhosted Meetings/conferences, Communicate With Other Users/solutions And Make/receive Calls Using Sip Accounts Registered To A Ucm6300 Series Ip Pbx Call Features: Call Park, Call Forward, Call Transfer, Call Waiting, Caller Id, Call Record, Call History, Ringtone, Ivr, Music On Hold, Call Routes, Did, Dod, Dnd, Disa, Ring Group, Ring Simultaneously, Time Schedule, Pin Groups, Call Queue, Pickup Group, Paging/intercom, Voicemail, Call Wakeup, Sca, Blf, Voicemail To Email, Fax To Email, Speed Dial, Call Back, Dial By Name, Emergency Call, Call Follow Me, Blacklist/whitelist, Voice Conference, Video Conference, Eventlist, Feature Codes, Busy Camp-on/ Call Completion, Voice Control, Post-meeting Reports, Virtual Fax Sending/receiving, Email To Fax Fxo Gateway (1 Unit) Network Interfaces 10m/100mbps, Dual Rj45 Ports Led Indicators Power, Network And Line Leds Voice-over-packet Capabilities G.168 Compiant Echo Cancelation, Dynamic Jitter Buffer, Moderm Detection & Auto-switch G.711 Ptsn Fail-over Life Line Ptsn Failover On Power Failure Voice Compression G.711, G.723, G.726 (40/32/24/16), G.729a/b/e, G.728, Ilbc Dhcp Client Yes, Switched Mode Or Pppoe Fax Over Ip T.38 Compliant Group 3 Fax Relay Up To 14.4kpbs & Auto-switch To G.711 For Fax Pass-through Qos Diffserve, Tos, 802.1p/q Vlan Tagging Ip Transport Rtp/rtcp Dtmf Method Flexible Dtmf Transmission Method, User Interface Of In-audio, Rfc2833, And/or Sip Info Ip Signaling Sip (rfc 3261) Ip Phone For Operator (1 Unit) Protocols/standards Sip Rfc3261, Tcp/ip/udp, Rtp/rtcp, Http/https, Arp, Icmp, Dns(a Record, Srv, Naptr), Dhcp, Pppoe, Telnet, Tftp, Ntp, Stun, Simple, Lldp, Ldap, Tr-069, 802.1x, Tls, Srtp, Ipv6 Network Interfaces Dual Switched Auto-sensing 10/100/1000 Mbps Gigabit Ethernet Ports With Integrated Poe Graphic Display 2.8 Inch (320x240) Tft Color Lc Wi-fi Yes, Integrated Dual-band Wi-fi 802.11 A/b/g/n/ac (2.4ghz & 5ghz) Bluetooth Yes, Integrated Feature Keys 8 Line Keys With Up To 4 Sip Accounts, 4 Xml Programmable Context Sensitive Softkeys, 5 Navigation/menu Keys, 9 Dedicated Function Keys For: Message(with Led Indicator), Transfer, Hold, Headset, Mute, Send/redial, Speakerphone, Vol+, Vol Auxiliary Port Rj9 Headset Jack Allowing Ehs With Plantronics Headsets, Usb To Support Grandstream’s Guv Series Headsets And Other Usb Headsets Telephony Features Hold, Transfer, Forward, 5-way Conference, Call Park, Call Pickup, Shared-callappearance(sca)/bridged-line-appearance(bla), Downloadable Phonebook(xml, Ldap, Up To 2000 Items), Call Waiting, Call Log(up To 2000 Records), Xml Customization Of Screen, Off-hook Auto Dial, Auto Answer, Click-to-dial, Flexible Dial Plan, Hot-desking, Personalized Music Ringtones And Music On Hold, Server Redundancy And Fail-over Hd Audio Yes, Hd Handset And Speakerphone With Support For Wideband Audio, And Dual Microphone. Extension Module Yes, Gbx20 Base Stand: Yes, 2 Angle Positions Available, Wall Mountable (wall Mount *sold Separately) Security: User And Administrator Level Passwords, Md5 And Md5-sess Based Authentication, 256-bit Aes Encrypted Configuration File, Srtp, Tls, 802.1x Media Access Control, Secure Boot Power & Green Energy Efficiency: Universal Power Adapter Included: Input: 100-240v ; Output: +12v, 1a ; Integrated Power-over-ethernet (802.3af) Max Power Consumption 9.5w (power Adapter) Or 10.8w (poe) Physical: Dimension: 220mmx 210mmx 82mm Unit Weight: 880g ; Package Weight:1260g Lcd Extension For Operator (1 Unit) Lines 20 Per Page (each Module Contain 2 Pages,for Up To 40 Lines Per Module Up To 160 With 4 Daisy Channel Modules Graphic Display 4.3 Inch (480x272) Tft Color Lcd Physical Dimension: 210mm*124mm*33.5mm; Unit Weight: 360g; Package Weight:700g Temperature And Humidity Operation: 0°c To 40°c Storage: -10°c To 60°c Humidity: 10% To 90% Non-condensing Phones Per Office (65 Units) Protocols/standards Sip Rfc3261, Tcp/ip/udp, Rtp/rtcp, Rtcp-xr, Http/https, Arp, Icmp, Dns(a Record, Srv, Naptr), Dhcp, Pppoe, Ssh, Tftp, Ntp, Stun, Simple, Lldp, Ldap, Tr069, Snmp, 802.1x, Tls, Srtp, Ipv6 Network Interfaces Dual Switched Auto-negotiation 10/100 Mbps Ethernet Ports, Integrated Poe Wi-fi Single Frequency, 2.4 Ghz, 802.11 B/g/n/ax (2.4g Only Graphic Display 132 X 48 (2.41’’) Lcd Display Feature Keys 4 Xml Programmable Context Sensitive Soft Keys, 5 (navigation, Menu) Keys. 8 Dedicated Function Keys For: Message(with Led Indicator), Transfer,headset, Mute, Send/redial, Speakerphone, Vol+, Vol Telephony Features Hold, Transfer, Forward, 5-way Conference, Call Park, Call Pickup, Downloadable Phonebook(xml, Ldap, Up To 2000 Items), Call Waiting, Call Log(up To 800 Records), Off-hook Auto Dial, Auto Answer, Click-to-dial, Flexible Dial Plan, Hot-desking, Personalized Music Ringtones And Music On Hold, Server Redundancy And Fail-over Qos Layer 2 Qos (802.1q, 802.1p) And Layer 3 (tos, Diffserv, Mpls) Qos Security User And Administrator Level Passwords, Md5 And Md5-sess Based Authentication, 256-bit Aes Encrypted Configuration File, Srtp, Tls, 802.1x Media Access Control, Secure Boot Power & Green Energy Efficiency Universal Power Supply Input 100-240vac 50-60hz; Output +5vdc, 600ma;poe: Ieee802.3af Class 1, 3.84w; Ieee802.3az (eee) Physical Dimension: 208mm (l) X 180mm (w) X 63.4mm (h) (with Handset) Unit Weight: 650g (651g For Grp2601w); Package Weight: 810g Router Dual Band (1 Unit) Standards Wifi 6 Ieee 802.11 Ax/ac/n/a 5ghz Ieee 802.11 Ax/n/b/g 2.4ghz Wfi Capacity Dual Band Allocate Devices To Different Bands For Optimal Performance Ofdma Simultaneously Communicates With Multiple Wi-fi 6 Clients Airtime Fairness Improves Network Efficency By Limiting Excessive Occupation Dfs Access An Extra Band Due To Reduce Congestion 4 Streams Connect Your Devices To More Bandwitdth Working Modes Router Mode Access Point Mode Processor 1x Gigabit Wan Port 4x Gigabit Lan Port Buttons Wi-fi/wps Button Power On/off Button Reset Button Dimension (wxdxh) 10.2x5.3x1.6in (260.2 X135 X 41.6mm) Network Switch Poe (3 Unit) Standards And Protocols Ieee 802.3i, Ieee 16× Gigabit Poe+ Rj45 Ports, 2× Gigabit Non-poe Rj45 Ports, And 2× Combo Gigabit Sfp Slots Network Media 10base -t: Utp Category 3,4,5 Cable (maximun 100m) 100base-tx/1000 Fan Quality Fanless Power Supply 100-240vac, 50/60 Power Consumption Maximum: 9.26w Dimensions (wxdxh) 11.6x7.1x1.7 In Switching Capacity 32gbps Packet Forwarding Rate 23.8mbps Mac Address Table 8k Jumbo Frame 10kb Green Technology Yes Transfer Method Store-and-forward Network Switch (1 Unit) Standards And Protocols Ieee 802.3i, Ieee 802.3u, Ieee 802.3ab, Ieee 802.3x Interface 16 10/100/1000mbps Rj45 Ports (auto Negotiation/auto Mdi/mdix) Network Media 100base-tx/1000base-t: Utp Category 5, 5e Or Above Cable (maximum 100m) Fan Quantity Fanless Physical Security Lock Power Supply 100-240vac, 50/60hz Power Consumption Maximum: 9.26w (220v/50hz) Dimensions (w X D X H) 11.6 X 7.1 X 1.7 In. (294 X 180 X 44 Mm) Max Power Consumption 9.95w (220v/50hz) Switching Capacity 32gbps Utp Cable (12 Boxes) Paired - Datatwist Category 5e ( Blue ) 4 Pair Utp 200mhz Category 5e Vertical Tray Rated 24 Awg Solid Bare Copper - Polyolefin Insulation - Pvc Jacket - Rip Cord Rj45 Io Port For Cat6 (66 Pcs) Bill Of Materials (moldings, Pvc Pipes, Sealants, Connectors) Inclusion: Labor, Installation Training And Commisioning 1 Year Free Service And Warranty **** Nothing Follows**** Total
The City Government Of Baguio Tender
Civil And Construction...+1Construction Material
Philippines
Closing Date19 Apr 2024
Tender AmountPHP 1.3 Million (USD 24 K)
Details: Description Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-45 Bidding March 27, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Fifteen (15) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 1 Lot Various Software Licenses 1,356,992.00 100 Unit Renewal Of Licenses For The 100 Units Multi Mode Ip Radio Communication Active Devices Of Bcpo For 12 Months A) Provision Of Advanced Annual Rental Poc ( Ptt Over Cellular) Package (voice +video+im+locating) With The Following Specifications: -gps Tracking Mechanism -able To Conduct Push-to-talk Communication Method -users Shall Be Able To Select And Engage A Call With The Command Center And And Among The Other Users -it Can Scan Every Groups In Idle , While A Group Call Is Established The Terminal Will Access It. -it Can Display The Groups Id And Alias Alternatively During A Call. -it Shall Support Individual Call And Group Call Ip To Ip Radio, Multi Groups Monitor, Sending And Receiving Corresponding Emergency Call, Group Call And Individual Call Based On The Google Map, Search Members And Content, Non-disturbing Function When Unnecessary Group Call Is Received, Clear And Deep Sound Effect Switching. Timeline : 7 Calendar Days With Testing And Commissioning 100 Unit Renewal Of Licenses For The 100 Units Multi Mode Ip Radio Communication Active Devices Of Bcpo For 12 Months B) Provision Of Voice Recording Services (voice+sds+video Per Terminal Per Year) With The Following Specifications: -gps Tracking Mechanism -able To Conduct Push-to-talk Communication Method -users Shall Be Able To Select And Engage A Call With The Command Center And And Among The Other Users -it Can Scan Every Groups In Idle , While A Group Call Is Established The Terminal Will Access It. -it Can Display The Groups Id And Alias Alternatively During A Call. -it Shall Support Individual Call And Group Call Ip To Ip Radio, Multi Groups Monitor, Sending And Receiving Corresponding Emergency Call, Group Call And Individual Call Based On The Google Map, Search Members And Content, Non-disturbing Function When Unnecessary Group Call Is Received, Clear And Deep Sound Effect Switching. Timeline : 7 Calendar Days With Testing And Commissioning Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Multi-purpose Hall, Baguio City Hall, Baguio City April 19, 2024 10 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 1 Of 2 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-45 Bidding March 27, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Fifteen (15) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 Unit Renewal Of Licenses For The 100 Units Multi Mode Ip Radio Communication Active Devices Of Bcpo For 12 Months C) Advance Web Console Annual Package (voice+video+im+avl) With The Following Specifications: -gps Tracking Mechanism -able To Conduct Push-to-talk Communication Method -users Shall Be Able To Select And Engage A Call With The Command Center And And Among The Other Users -it Can Scan Every Groups In Idle , While A Group Call Is Established The Terminal Will Access It. -it Can Display The Groups Id And Alias Alternatively During A Call. -it Shall Support Individual Call And Group Call Ip To Ip Radio, Multi Groups Monitor, Sending And Receiving Corresponding Emergency Call, Group Call And Individual Call Based On The Google Map, Search Members And Content, Non-disturbing Function When Unnecessary Group Call Is Received, Clear And Deep Sound Effect Switching. Timeline : 7 Calendar Days With Testing And Commissioning This Is A Lot Bidding, Partial Bids Are Not Allowed Please Indicate Unit Prices Of Offers In The Financial Proposal Bidders Must Possess Valid Mayor's/business Permit With A Relevant Line Of Business In Radio Software Licenses For Use Of Bcpo Under Pr No. 459 Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Multi-purpose Hall, Baguio City Hall, Baguio City April 19, 2024 10 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 2 Of 2
DEPT OF THE ARMY USA Tender
Civil And Construction...+1Road Construction
United States
Closing Date10 Jun 2024
Tender AmountRefer Documents
Details: Amendment 0001: 1.extend The Response Date To 10 June 2024 2. Post Revised Scope Dated 28 May 2024 3. Post Q&a. this Amendment Is Located In The Attachment Section And Named " Amendment 00001 Update Sow" please Remember To Acknolwedge All Amendments With Your Submission. synopsis Of A-e Services pavement Condition Survey & Micropaver™ Reinspection, Fort Riley Roads, Kansas classification Code: Service Code C (architect And Engineering Services) subject: Pavement Condition Survey & Micropaver™ Reinspection, Fort Riley Roads And Parking, Kansas description: 1. Contract Information. this Solicitation Is Restricted To Small Business Participation the North American Industry Classification System (naics) Is 541330 – Engineering Services And Small Business Size Standard Is $25.5m. this Contract Is Being Procured In Accordance With The Brooks A-e Act As Implemented In Far Subpart 36.6. Firms Will Be Selected For Negotiation Based On Demonstrated Competence And Qualifications For The Required Work. contract Type: This Will Be A Single Firm Fixed Price (ffp) Purchase Order. performance Period: Twelve Months After Purchase Order Award. Estimated Start And Completion Dates Of All Work Is June 2024 And June 2025, Respectively. options: There Are No Options Included In This Contract. range Of Estimated A&e Price: Under Simplified Acquisition Threshold (sat), Under $250,000. subcontracting Plan: Not Required. this Contract Is Subject To The Service Contract Labor Standards And The Current Service Contract Act Wage Decision (sca Wd) For The Location Of Work Has Been Attached. The Sca Wd For The Awardee’s Home Office Will Be Applicable And Included At Award. all Interested Vendors Are Required To Be Registered In Sam.gov With A Valid Commercial And Government Entity Program (cage) Code And Unique Entity Identifiyer (uei). 2. Project Information. a-e Services Shall Include Pavement Inspection Utilizing Paver™ Version 7.1 Or Higher Located At Fort Riley, Kansas. Work Shall Be Accomplished In Accordance With Astm D6433 (20 Or Later) With Exception To The Sampling Rate As Identified In The Scope Of Work (see Attachments). reference The Scope Of Work For Additional Information Regarding Qualifications Of Personnel, Coordination, Permitting, Field Surveying, Scheduling, Submittals, Government Ownership, Antiterrorism And Security Provisions, Major Requirements, Modeling, Analysis, 10-year Working Analysis, Project Development, Meetings, Isr Reporting, Draft And Final Reporting, Quality Assurance, Deliverables, And Points Of Contact. 3. Selection Criteria: The Selection Criteria For This Particular Project Are Listed Below In Descending Order Of Importance. a. Specialized Experience And Technical Competence: Submittals Shall Demonstrate The Specialized Experience And Technical Competence To Execute The Types Of Projects And Activities As Indicated Above In Paragraph 2, Project Information. Experience Implementing The Paver™ Pavement Management System Using The Paver™ Software Version 6 Or Newer (paver™ 7 Experience Is Preferred) And Manual Pavement Distress Data Collection. Submit No More Than Four (4) Examples Of Paver™ Implementation Projects Using The Paver™ Software And Pavement Management System And Manual Distress Data Collection. Example Projects Should Be Submitted For Roads And Parking Only. Paver™ Implementation Experience On Army Or Air Force Installations Is Desirable But Not Essential. Only Relatable Experience That Has Occurred In The Last Five Years Should Be Included In The Submittal. Project Examples Submitted Should Be Of Completed Projects. All Projects Cited Shall Identify Start/complete Dates, Project Size (pavement Area, Cost And Scope) And Tasks Performed. In Addition To The Example Projects Above, Include A List (sf 330, Part I, Section H) Of Any Other Paver™ Implementations Using Manual Pavement Distress Data Collection Completed Within The Last Five Years Including Location, Customer, Pavement Type (roads, Parking Areas, Airfields, Etc.) And Area Of Pavement Inspected. (sf 330, Part I, Section F) b. Professional Qualifications: Firms Shall Demonstrate Professional Personnel Qualifications And Specialized Experience For Key Disciplines. Evaluation Of Professional Qualifications Will Consider Education, Training, Relevant Experience And Longevity With The Firm. Experience Working On Applicable Army And Air Force Projects Is Desirable And Should Be Identified. (sf 330, Part I, Sections E & G). provide Resumes For A Minimum Of One (1) Project Manager (team Leader), Project Managers Should Be A U.s. Registered Professional Engineer And Have At Least Five (5) Years Of Experience Implementing The Paver™ Pavement Management System. provide Resumes For A Minimum Of Two (2) Civil Engineers. Civil Engineers Should Have A Minimum Of Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Civil Engineers Should Have A Thorough Knowledge Of The Paver™ Software And Paver™ Pavement Management System And Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. Civil Engineers Should Be A U.s. Registered Professional Engineer. List Recent Paver™ Software Training Attended. provide Resumes For A Minimum Of Two (2) Engineering Technicians. Engineering Technicians Should Have At Least Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Engineer Technicians Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Knowledge And Experience Using The Paver™ Software Is Desirable. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. List Recent Paver™ Software Training Attended. provide Resume For A Minimum Of One (1) Gis Technician. Gis Technician Should Have At Least One (1) Year Of Experience Creating/updating Paver™ Gis Network Shapefiles. c. Past Performance. Past Performance On Dod And Other Contracts With Respect To The Quality Of Work And Compliance With Performance Schedules, As Determined By Cpars And Other Sources. Submit Entire Cpars Evaluations, Not Summaries Of Ratings. Provide Cpars For The 4 Projects Identified In Section I Only. Provide Ppq In The Event That Cpars Does Not Exist. Firms Which Choose To Use The Ppq May Obtain A Ppq In The Attachments Section Of This Sam Posting. If Issues Arise, A Ppq Form Can Be Obtained By Submitting A Request To The Below Referenced Poc Via Email. d. Proposed Management Plan. A Proposed Management Plan Shall Be Presented That Includes An Organization Chart (reference Sf330, Part I, Section D) And Addresses Team Organization (reference Sf330, Part I, Section C), Any Anticipated Sub-contractors Or Entities To Supplement The Design Team, Quality Control Procedures, Cost Control, Coordination Of In-house Disciplines And Consultants Required To Meet Work Capacity. Organizational Chart Should Clearly Indicate Available Inspection Teams. the Sf 330 Shall Clearly Indicate The Primary Office Where The Work Will Be Performed And The Staffing At That Office. (sf 330, Part I, Section H, Item 2). 4. Submission Requirements: In An Effort To Reduce Paper And Cost, All Proposals Shall Be submitted Electronically. All Submissions Will Be In Adobe Pdf Format With Optical Character Recognition (ocr) Applied To All Documents That Will Enable Word Searches To Be Conducted Using Adobe- Compatible Pdf Software. The Two (2) Sf330s Listed Below Shall Be Submitted As Separate Files Via Email. Offerors Should Follow Controlled Unclassified Information (cui) Guidelines And Use Proper Markings If Submitting Documents That Are Considered Cui. Proper Markings Include The Following: Banner Markings Should Appear Above The Email Text Containing Cui, The Email Subject Line Should Also Indicate The Email Contains Cui, And File Names For Any Attachments Containing Cui. Offerors May Use Or Pkzip To Reduce File Size And Facilitate Transmission. offerors Are Encouraged To Send Both Files In The Same Email Transmission, If Possible. interested Firms Having The Capabilities To Perform This Work Must Submit Electronically One (1) Copy Of The Sf 330 Part I, And One (1) Copy Of Sf 330 Part Ii For The Prime Firm And All Consultants/subcontractors, To The Following (3) Three Recipients With Subject Line “fort Riley Paver Synopsis Response” Not Later Than 2:00 Pm Mountain Time (mt) On The Response Date Indicated In This Announcement: 1. Kelly Hopper; Kelly.c.hopper@usace.army.mil 2. Jessica Beckman; Jessica.l.merrill2@usace.army.mil 3. Cenwo Ct Fsrm Doc Submission; Cenwo-ct-fsrm-doc-submission@usace.army.mil for File Sizes Greater Than 20 Megabytes (mb) The Firm Shall Break The File Into Smaller Files Sent Via Separate Emails With Each Email Marked To Identify Which Number The Email Is Relative To The Total Number Of Emails Submitted (i.e. “email 1 Of 2”). Once All Emails Submitted Have Been Received The Government Will Confirm Receipt Via Responsive Email. for The Purposes Of Determining Whether The Proposal Was Received “late” In Accordance With Far 15.208, The Date And Time (mountain Time) The File(s) Are Received Via Email Will Be The Date And Time (mountain Time) The Government Received The Proposal. Do Not Assume That Electronic Communication Is Instantaneous. Please Make Allowances For Delays In Transmittal. The Government Is Not Responsible For Proposals Delivered To Any Location Or To Anyone Other Than Those Designated To Receive Proposals On Its Behalf. The Offeror Is Responsible For Ensuring That The Proposal Is Submitted So As To Reach The Designated Recipient And Is Responsible For Allowing Sufficient Time For The Proposal To Be Received In Accordance With The Information Provided. Failure To Submit A Complete Proposal Iaw Instructions And Requirements May Result In The Entire Offer Being Rejected. sf 330, 07/2021 Edition, Must Be Used, And May Be Obtained From The Following Website: https://www.gsa.gov/reference/forms/architectengineer-qualifications. Include Sam Uei Number And Cage Code In Sf330 Part I, Section B, Block 5. Additionally, The Sam Uei Number And Cage Code Should Be Identified In Sf 330 Part I, Section C, Block 9, For Each Team Member. the Submittal Shall Have A Page Limit Of 50 Pages (total Of 50 Pages Allowed For Complete Copy Of The Submittal, All-inclusive). The Selection Board Will Not Evaluate Beyond 50 Pages. A Page Is One Side Of A Sheet. Blank Sheets/tabs Separating The Sections Within The Sf 330 Will Not Count Against The Maximum Page Count. All Fonts Shall Be At Least 10 Pitch Or Larger And Have Text Of Arial, Times New Roman, Or Calibri. Pages Shall Be 8-1/2 Inches By 11 Inches. Margins Should Be No Less Than 1” (right, Left, Top, And Bottom). An Sf 330 Part Ii Is Required For Each Branch Office Of The Prime Firm And Any Consultants/subcontractors That Will Have A Key Role In The Proposed Contract (i.e. A Part Ii Is Required For All Entities Identified In Sf 330 Part I, Section C Of The Submittal). Cover Letters, Company Literature And Extraneous Materials Are Not Desired And Will Not Be Considered. Sections E And G Of Sf 330 Part I Must Include Only Individuals Proposed To Perform The Anticipated Work, Including All Consultants/subcontractors. In Sf 330 Part I, Section G, Block 26, Along With The Name, Include The Firm With Which The Person Is Associated. A Maximum Of Four (4) Projects Including The Prime And Consultants/subcontractors Will Be Reviewed For Sf 330 Part I, Section F. If More Than 4 Projects Are Submitted, Only The First 4 Projects Will Be Evaluated. Use No More Than Two (2) Pages Per Project. When Listing Projects In Sf 330 Part 1, Section F, An Indefinite Delivery Contract (idc) With Multiple Task Orders As Examples Is Not Considered A Project. A Task Order Executed Under An Idc Contract Is A Project. Past Performance Evaluations (cpars/acass, Ppq – Reference Paragraph 3.d. Above) Shall Be Submitted For Each Project Provided In Sf 330, Part I, Section F. Sf 330, Part I, Section H (additional Information) Shall Contain The Following Information. Sf 330, Part I, Section H (additional Information) Shall Contain The Information In Paragraph 3.d Above Regarding Management Plan. joint Ventures Shall Submit The Following Additional Documentation Of The Evidence Of A Joint Venture Entity: 1) Firms Shall Provide A Copy Of A Legally Binding Joint Venture Agreement, And 2) Identification Of The Party Who Can Legally Bind The Joint Venture. a Draft Solicitation Is Provided With This Announcement. The Purpose Of This Draft Solicitation Is For Industry To Be Able To Review The Provisions, Clauses, Terms, And Conditions. This Is Not A Request For Proposal. A Price Proposal Is Not Requested With This Announcement. The Corps Will Review Contractor Qualifications And Select The Most Highly Qualified Firm. That Firm Will Receive The Solicitation And A Proposal Will Be Requested And Negotiated With That Firm. all Questions Shall Be Submitted Via The Bidder Inquiry Portal In Projnet At Http://www.projnet.org/projnet. Questions Should Be Submitted No Later Than 27 May 2024 At 2:00 P.m. Mountain Time To Allow Time For A Response. On This Date And Time The Portal Will Be Closed. For Questions, No Other Means Of Communication, E-mail, Fax, Or Telephone Will Be Accepted. To Submit And Review Inquiry Items, Prospective Vendors Will Need To Use The Bidder Inquiry Key Presented Below And Follow The Instructions Listed Below. A Prospective Vendor Who Submits A Comment/question Will Receive An Acknowledgement Of Their Comment/question Via Email, Followed By An Answer To The Comment/question After It Has Been Processed By Our Team. All Timely Questions And Approved Answers Will Be Made Available Through Projnet. To Submit And Review Inquiries, Firms Will Need To Be Current Registered Users Of The Projnet System. registration For Projnet Bidder Inquiry Access (if You Are Already Registered, Go To Entering Bidder Inquiries In Projnet Bidder Inquiry System Below.) 1. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 2. Identify The Agency. This Should Be Marked As Usace. 3. Key. Enter The Bidder Inquiry Key Listed Below. 4. Email. Enter The Email Address You Would Like To Use For Communication. 5. Click Continue. A Page Will Then Open Saying That A User Account Was Not Found And Will Ask You To Create One Using The Provided Form. 6. Enter Your First Name, Last Name, Company, City, State, Phone, Email, Secret Question, Secret Answer, And Time Zone. Make Sure To Remember Your Secret Question And Answer As They Will Be Used From This Point On To Access The Projnet System. 7. Click Add User. Once This Is Completed You Are Now Registered Within Projnet And Are Currently Logged Into The System. entering Bidder Inquiries In Projnet Bidder Inquiry System 1. For Future Access To Projnet, You Will Not Be Emailed Any Type Of Password. You Will Utilize Your Secret Question And Secret Answer To Log In. 2. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 3. Identify The Agency. This Should Be Marked As Usace. 4. Key. Enter The Bidder Inquiry Key Listed Below. 5. Email. Enter The Email Address You Used To Register Previously In Projnet. 6. Click Continue. A Page Will Then Open Asking You To Enter The Answer To Your Secret Question. 7. Enter Your Secret Answer And Click Login. Once This Is Completed You Are Now Logged Into The System. 8. Follow Online Screen Instructions To Enter Specific Bidder Inquiries For The Project. the Solicitation Number Is: W9128f-24-r-0055 the Bidder Inquiry Key Is: Ryhcfj-4j9wb7 firms Are Requested To Review The Bidder Inquiry Portal For Previous Questions And Responses, Prior To Submission Of A New Inquiry In The Portal. Caution: Any Inquiry Submitted And Answered Within This System Will Be Accessible To View By All Interested Firms On This Solicitation. The Call Center For The Projnet Operates Weekdays From 8 Am To 5 Pm U.s. Central Time Zone. The Telephone Number Is 1-800-428-help. 5. Place Of Contract Performance: as Noted Above Service Contract Act Wage Decisions Will Be Applicable To Both The Project Site, Fort Riley, Kansas, And The Awardee’s Home Office (this Wage Decision Will Be Provided At Award).
DEPT OF THE ARMY USA Tender
United States
Closing Date15 Aug 2024
Tender AmountRefer Documents
Details: Synopsis Of A-e Services pavement Condition Survey & Micropaver™ Reinspection, Fort Wainwright Alaska classification Code: Service Code C (architect And Engineering Services) subject: Pavement Condition Survey & Micropaver™ Reinspection, Fort Wainwright Alaska description: 1. Contract Information. this Solicitation Is Restricted To Small Business Participation the North American Industry Classification System (naics) Is 541330 – Engineering Services And Small Business Size Standard Is $25.5m. this Contract Is Being Procured In Accordance With The Brooks A-e Act As Implemented In Far Subpart 36.6. Firms Will Be Selected For Negotiation Based On Demonstrated Competence And Qualifications For The Required Work. contract Type: This Will Be A Single Firm Fixed Price (ffp) Purchase Order. performance Period: Twelve Months After Purchase Order Award. Estimated Start And Completion Dates Of All Work Is September 2024 And September 2025, Respectively. options: There Are No Options Included In This Contract. range Of Estimated A&e Price: Under Simplified Acquisition Threshold (sat), Under $250,000. subcontracting Plan: Not Required. this Contract Is Subject To The Service Contract Labor Standards And The Current Service Contract Act Wage Decision (sca Wd) For The Location Of Work Has Been Attached. The Sca Wd For The Awardee’s Home Office Will Be Applicable And Included At Award. all Interested Vendors Are Required To Be Registered In Sam.gov With A Valid Commercial And Government Entity Program (cage) Code And Unique Entity Identifier (uei). 2. Project Information. a-e Services Shall Include Pavement Inspection Utilizing Paver™ Version 7.1.2 Or Higher Located At Fort Wainwright Alaska. Work Shall Be Accomplished In Accordance With Astm D6433 (20 Or Later) With Exception To The Sampling Rate As Identified In The Scope Of Work (see Attachments). reference The Scope Of Work For Additional Information Regarding Qualifications Of Personnel, Coordination, Permitting, Field Surveying, Scheduling, Submittals, Government Ownership, Antiterrorism And Security Provisions, Major Requirements, Modeling, Analysis, 10-year Working Analysis, Project Development, Meetings, Isr Reporting, Draft And Final Reporting, Quality Assurance, Deliverables, And Points Of Contact. 3. Selection Criteria: The Selection Criteria For This Particular Project Are Listed Below In Descending Order Of Importance. a. Specialized Experience And Technical Competence: Submittals Shall Demonstrate The Specialized Experience And Technical Competence To Execute The Types Of Projects And Activities As Indicated Above In Paragraph 2, Project Information. Experience Implementing The Paver™ Pavement Management System Using The Paver™ Software Version 6 Or Newer (paver™ 7 Experience Is Preferred) And Manual Pavement Distress Data Collection. Submit No More Than Four (4) Examples Of Paver™ Implementation Projects Using The Paver™ Software And Pavement Management System And Manual Distress Data Collection. Example Projects Should Be Submitted For Roads And Parking Only. Paver™ Implementation Experience On Army Or Air Force Installations Is Desirable But Not Essential. Only Relatable Experience That Has Occurred In The Last Five Years Should Be Included In The Submittal. Project Examples Submitted Should Be Of Completed Projects. All Projects Cited Shall Identify Start/complete Dates, Project Size (pavement Area, Cost And Scope) And Tasks Performed. In Addition To The Example Projects Above, Include A List (sf 330, Part I, Section H) Of Any Other Paver™ Implementations Using Manual Pavement Distress Data Collection Completed Within The Last Five Years Including Location, Customer, Pavement Type (roads, Parking Areas, Airfields, Etc.) And Area Of Pavement Inspected. (sf 330, Part I, Section F) b. Professional Qualifications: Firms Shall Demonstrate Professional Personnel Qualifications And Specialized Experience For Key Disciplines. Evaluation Of Professional Qualifications Will Consider Education, Training, Relevant Experience And Longevity With The Firm. Experience Working On Applicable Army And Air Force Projects Is Desirable And Should Be Identified. (sf 330, Part I, Sections E & G). provide Resumes For A Minimum Of One (1) Project Manager (team Leader), Project Managers Should Be A U.s. Registered Professional Engineer And Have At Least Five (5) Years Of Experience Implementing The Paver™ Pavement Management System. provide Resumes For A Minimum Of Two (2) Civil Engineers. Civil Engineers Should Have A Minimum Of Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Civil Engineers Should Have A Thorough Knowledge Of The Paver™ Software And Paver™ Pavement Management System And Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. Civil Engineers Should Be A U.s. Registered Professional Engineer. List Recent Paver™ Software Training Attended. provide Resumes For A Minimum Of Two (2) Engineering Technicians. Engineering Technicians Should Have At Least Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Engineer Technicians Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Knowledge And Experience Using The Paver™ Software Is Desirable. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. List Recent Paver™ Software Training Attended. provide Resume For A Minimum Of One (1) Gis Technician. Gis Technician Should Have At Least One (1) Year Of Experience Creating/updating Paver™ Gis Network Shapefiles. c. Past Performance. Past Performance On Dod And Other Contracts With Respect To The Quality Of Work And Compliance With Performance Schedules, As Determined By Cpars And Other Sources. Submit Entire Cpars Evaluations, Not Summaries Of Ratings. Provide Cpars For The 4 Projects Identified In Section I Only. Provide Ppq In The Event That Cpars Does Not Exist. Firms Which Choose To Use The Ppq May Obtain A Ppq In The Attachments Section Of This Sam Posting. If Issues Arise, A Ppq Form Can Be Obtained By Submitting A Request To The Below Referenced Poc Via Email. d. Proposed Management Plan. A Proposed Management Plan Shall Be Presented That Includes An Organization Chart (reference Sf330, Part I, Section D) And Addresses Team Organization (reference Sf330, Part I, Section C), Any Anticipated Sub-contractors Or Entities To Supplement The Design Team, Quality Control Procedures, Cost Control, Coordination Of In-house Disciplines And Consultants Required To Meet Work Capacity. Organizational Chart Should Clearly Indicate Available Inspection Teams. the Sf 330 Shall Clearly Indicate The Primary Office Where The Work Will Be Performed And The Staffing At That Office. (sf 330, Part I, Section H, Item 2). 4. Submission Requirements: In An Effort To Reduce Paper And Cost, All Proposals Shall Be submitted Electronically. All Submissions Will Be In Adobe Pdf Format With Optical Character Recognition (ocr) Applied To All Documents That Will Enable Word Searches To Be Conducted Using Adobe- Compatible Pdf Software. The Two (2) Sf330s Listed Below Shall Be Submitted As Separate Files Via Email. Offerors Should Follow Controlled Unclassified Information (cui) Guidelines And Use Proper Markings If Submitting Documents That Are Considered Cui. Proper Markings Include The Following: Banner Markings Should Appear Above The Email Text Containing Cui, The Email Subject Line Should Also Indicate The Email Contains Cui, And File Names For Any Attachments Containing Cui. Offerors May Use Or Pkzip To Reduce File Size And Facilitate Transmission. offerors Are Encouraged To Send Both Files In The Same Email Transmission, If Possible. interested Firms Having The Capabilities To Perform This Work Must Submit Electronically One (1) Copy Of The Sf 330 Part I, And One (1) Copy Of Sf 330 Part Ii For The Prime Firm And All Consultants/subcontractors, To The Following (3) Three Recipients With Subject Line Redstone Arsenal Paver Synopsis Response” No Later Than 2:00pm Mountain Time (mt) On The Response Date Indicated In This Announcement: 1. Steve Engen; Steven.d.engen@usace.army.mil 2. Jessica Beckman; Jessica.l.merrill2@usace.army.mil 3. Cenwo Ct Fsrm Doc Submission; Cenwo-ct-fsrm-doc-submission@usace.army.mil for File Sizes Greater Than 20 Megabytes (mb) The Firm Shall Break The File Into Smaller Files Sent Via Separate Emails With Each Email Marked To Identify Which Number The Email Is Relative To The Total Number Of Emails Submitted (i.e. “email 1 Of 2”). Once All Emails Submitted Have Been Received The Government Will Confirm Receipt Via Responsive Email. for The Purposes Of Determining Whether The Proposal Was Received “late” In Accordance With Far 15.208, The Date And Time (mountain Time) The File(s) Are Received Via Email Will Be The Date And Time (mountain Time) The Government Received The Proposal. Do Not Assume That Electronic Communication Is Instantaneous. Please Make Allowances For Delays In Transmittal. The Government Is Not Responsible For Proposals Delivered To Any Location Or To Anyone Other Than Those Designated To Receive Proposals On Its Behalf. The Offeror Is Responsible For Ensuring That The Proposal Is Submitted So As To Reach The Designated Recipient And Is Responsible For Allowing Sufficient Time For The Proposal To Be Received In Accordance With The Information Provided. Failure To Submit A Complete Proposal Iaw Instructions And Requirements May Result In The Entire Offer Being Rejected. sf 330, 07/2021 Edition, Must Be Used, And May Be Obtained From The Following Website: https://www.gsa.gov/reference/forms/architectengineer-qualifications. Include Sam Uei Number And Cage Code In Sf330 Part I, Section B, Block 5. Additionally, The Sam Uei Number And Cage Code Should Be Identified In Sf 330 Part I, Section C, Block 9, For Each Team Member. the Submittal Shall Have A Page Limit Of 50 Pages (total Of 50 Pages Allowed For Complete Copy Of The Submittal, All-inclusive). The Selection Board Will Not Evaluate Beyond 50 Pages. A Page Is One Side Of A Sheet. Blank Sheets/tabs Separating The Sections Within The Sf 330 Will Not Count Against The Maximum Page Count. All Fonts Shall Be At Least 10 Pitch Or Larger And Have Text Of Arial, Times New Roman, Or Calibri. Pages Shall Be 8-1/2 Inches By 11 Inches. Margins Should Be No Less Than 1” (right, Left, Top, And Bottom). An Sf 330 Part Ii Is Required For Each Branch Office Of The Prime Firm And Any Consultants/subcontractors That Will Have A Key Role In The Proposed Contract (i.e. A Part Ii Is Required For All Entities Identified In Sf 330 Part I, Section C Of The Submittal). Cover Letters, Company Literature And Extraneous Materials Are Not Desired And Will Not Be Considered. Sections E And G Of Sf 330 Part I Must Include Only Individuals Proposed To Perform The Anticipated Work, Including All Consultants/subcontractors. In Sf 330 Part I, Section G, Block 26, Along With The Name, Include The Firm With Which The Person Is Associated. A Maximum Of Four (4) Projects Including The Prime And Consultants/subcontractors Will Be Reviewed For Sf 330 Part I, Section F. If More Than 4 Projects Are Submitted, Only The First 4 Projects Will Be Evaluated. Use No More Than Two (2) Pages Per Project. When Listing Projects In Sf 330 Part 1, Section F, An Indefinite Delivery Contract (idc) With Multiple Task Orders As Examples Is Not Considered A Project. A Task Order Executed Under An Idc Contract Is A Project. Past Performance Evaluations (cpars/acass, Ppq – Reference Paragraph 3.d. Above) Shall Be Submitted For Each Project Provided In Sf 330, Part I, Section F. Sf 330, Part I, Section H (additional Information) Shall Contain The Following Information. Sf 330, Part I, Section H (additional Information) Shall Contain The Information In Paragraph 3.d Above Regarding Management Plan. joint Ventures Shall Submit The Following Additional Documentation Of The Evidence Of A Joint Venture Entity: 1) Firms Shall Provide A Copy Of A Legally Binding Joint Venture Agreement, And 2) Identification Of The Party Who Can Legally Bind The Joint Venture. a Draft Solicitation Is Provided With This Announcement. The Purpose Of This Draft Solicitation Is For Industry To Be Able To Review The Provisions, Clauses, Terms, And Conditions. This Is Not A Request For Proposal. A Price Proposal Is Not Requested With This Announcement. The Corps Will Review Contractor Qualifications And Select The Most Highly Qualified Firm. That Firm Will Receive The Solicitation And A Proposal Will Be Requested And Negotiated With That Firm. all Questions Shall Be Submitted Via The Bidder Inquiry Portal In Projnet At Http://www.projnet.org/projnet. Questions Should Be Submitted No Later Than 06 Aug 2024 At 2:00 P.m. Mountain Time To Allow Time For A Response. On This Date And Time The Portal Will Be Closed. For Questions, No Other Means Of Communication, E-mail, Fax, Or Telephone Will Be Accepted. To Submit And Review Inquiry Items, Prospective Vendors Will Need To Use The Bidder Inquiry Key Presented Below And Follow The Instructions Listed Below. A Prospective Vendor Who Submits A Comment/question Will Receive An Acknowledgement Of Their Comment/question Via Email, Followed By An Answer To The Comment/question After It Has Been Processed By Our Team. All Timely Questions And Approved Answers Will Be Made Available Through Projnet. To Submit And Review Inquiries, Firms Will Need To Be Current Registered Users Of The Projnet System. registration For Projnet Bidder Inquiry Access (if You Are Already Registered, Go To Entering Bidder Inquiries In Projnet Bidder Inquiry System Below.) 1. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 2. Identify The Agency. This Should Be Marked As Usace. 3. Key. Enter The Bidder Inquiry Key Listed Below. 4. Email. Enter The Email Address You Would Like To Use For Communication. 5. Click Continue. A Page Will Then Open Saying That A User Account Was Not Found And Will Ask You To Create One Using The Provided Form. 6. Enter Your First Name, Last Name, Company, City, State, Phone, Email, Secret Question, Secret Answer, And Time Zone. Make Sure To Remember Your Secret Question And Answer As They Will Be Used From This Point On To Access The Projnet System. 7. Click Add User. Once This Is Completed You Are Now Registered Within Projnet And Are Currently Logged Into The System. entering Bidder Inquiries In Projnet Bidder Inquiry System 1. For Future Access To Projnet, You Will Not Be Emailed Any Type Of Password. You Will Utilize Your Secret Question And Secret Answer To Log In. 2. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 3. Identify The Agency. This Should Be Marked As Usace. 4. Key. Enter The Bidder Inquiry Key Listed Below. 5. Email. Enter The Email Address You Used To Register Previously In Projnet. 6. Click Continue. A Page Will Then Open Asking You To Enter The Answer To Your Secret Question. 7. Enter Your Secret Answer And Click Login. Once This Is Completed You Are Now Logged Into The System. 8. Follow Online Screen Instructions To Enter Specific Bidder Inquiries For The Project. the Solicitation Number Is: W9128f-24-q-0073 the Bidder Inquiry Key Is: U9vmjc-9ni29z firms Are Requested To Review The Bidder Inquiry Portal For Previous Questions And Responses, Prior To Submission Of A New Inquiry In The Portal. Caution: Any Inquiry Submitted And Answered Within This System Will Be Accessible To View By All Interested Firms On This Solicitation. The Call Center For The Projnet Operates Weekdays From 8 Am To 5 Pm U.s. Central Time Zone. The Telephone Number Is 1-800-428-help. 5. Place Of Contract Performance: as Noted Above Service Contract Act Wage Decisions Will Be Applicable To Both The Project Site, Fort Wainwright, Alaska And The Awardee’s Home Office (this Wage Decision Will Be Provided At Award).
DEPT OF THE ARMY USA Tender
Software and IT Solutions
United States
Closing Date25 Mar 2024
Tender AmountRefer Documents
Details: Amendment 0002 date Of Issue: 07 March 2024 date Of Receiving Responses To Synopsis: Remains 25 March 2023 At 2:00 P.m. Central Time there Are No Updates To The Attachments. corrections To The Synopsis Is As Follows: the Sf 330, 07/2021 Edition, Must Be Used, And May Be Obtained From The Following Website: Https://www.gsa.gov/reference/forms/architectengineer-qualifications amendment 0001 date Of Issue: 01february 2024 date Of Receiving Responses To Synopsis: Remains 25 March 2023 At 2:00 P.m. Central Time see Attached Am-0001_draft Solicitation With Scope Of Work Which Updates The Page 1 (sf 1449) Box 10 To “small Business” As Highlighted. corrections To The Synopsis Are As Follows: the Bidder Inquiry Key Is: G97kiv-i374e8 questions Should Be Submitted No Later Than 15 March 2024 At 2:00 P.m. Central Time To Allow Time For A Response. synopsis Of A-e Services pavement Condition Survey & Micropaver™ Reinspection, Fort Campbell Roads, Kentucky classification Code: Service Code C (architect And Engineering Services) subject: Pavement Condition Survey & Micropaver™ Reinspection, Fort Campbell Roads, Kentucky description: 1. Contract Information. this Solicitation Is Restricted To Small Business Participation the North American Industry Classification System (naics) Is 541330 – Engineering Services And Small Business Size Standard Is $25.5m. this Contract Is Being Procured In Accordance With The Brooks A-e Act As Implemented In Far Subpart 36.6. Firms Will Be Selected For Negotiation Based On Demonstrated Competence And Qualifications For The Required Work. contract Type: This Will Be A Single Firm Fixed Price (ffp) Purchase Order. performance Period: Twelve Months After Purchase Order Award. Estimated Start And Completion Dates Of All Work Is April 2024 And April 2025, Respectively. options: There Are No Options Included In This Contract. range Of Estimated A&e Price: Under Simplified Acquisition Threshold (sat), Under $250,000. subcontracting Plan: Not Required. this Contract Is Subject To The Service Contract Labor Standards And The Current Service Contract Act Wage Decision (sca Wd) For The Location Of Work Has Been Attached. The Sca Wd For The Awardee’s Home Office Will Be Applicable And Included At Award. all Interested Vendors Are Required To Be Registered In Sam.gov With A Valid Commercial And Government Entity Program (cage) Code. 2. Project Information. a-e Services Shall Include Pavement Inspection Utilizing Paver™ Version 7.1 Or Higher Located At Fort Campbell, Kentucky. Work Shall Be Accomplished In Accordance With Astm D6433 (20 Or Later) With Exception To The Sampling Rate As Identified In The Scope Of Work (see Attachments). reference The Scope Of Work For Additional Information Regarding Qualifications Of Personnel, Coordination, Permitting, Field Surveying, Scheduling, Submittals, Government Ownership, Antiterrorism And Security Provisions, Major Requirements, Modeling, Analysis, 10-year Working Analysis, Project Development, Meetings, Isr Reporting, Draft And Final Reporting, Quality Assurance, Deliverables, And Points Of Contact. 3. Selection Criteria: The Selection Criteria For This Particular Project Are Listed Below In Descending Order Of Importance. a. Specialized Experience And Technical Competence: Submittals Shall Demonstrate The Specialized Experience And Technical Competence To Execute The Types Of Projects And Activities As Indicated Above In Paragraph 2, Project Information. Experience Implementing The Paver™ Pavement Management System Using The Paver™ Software Version 6 Or Newer (paver™ 7 Experience Is Preferred) And Manual Pavement Distress Data Collection. Submit No More Than Four (4) Examples Of Paver™ Implementation Projects Using The Paver™ Software And Pavement Management System And Manual Distress Data Collection. Example Projects Should Be Submitted For Roads And Parking Only. Paver™ Implementation Experience On Army Or Air Force Installations Is Desirable But Not Essential. Only Relatable Experience That Has Occurred In The Last Five Years Should Be Included In The Submittal. Project Examples Submitted Should Be Of Completed Projects. All Projects Cited Shall Identify Start/complete Dates, Project Size (pavement Area, Cost And Scope) And Tasks Performed. In Addition To The Example Projects Above, Include A List (sf 330, Part I, Section H) Of Any Other Paver™ Implementations Using Manual Pavement Distress Data Collection Completed Within The Last Five Years Including Location, Customer, Pavement Type (roads, Parking Areas, Airfields, Etc.) And Area Of Pavement Inspected. (sf 330, Part I, Section F) b. Professional Qualifications: Firms Shall Demonstrate Professional Personnel Qualifications And Specialized Experience For Key Disciplines. Evaluation Of Professional Qualifications Will Consider Education, Training, Relevant Experience And Longevity With The Firm. Experience Working On Applicable Army And Air Force Projects Is Desirable And Should Be Identified. (sf 330, Part I, Sections E & G). provide Resumes For A Minimum Of One (1) Project Manager (team Leader), Project Managers Should Be A U.s. Registered Professional Engineer And Have At Least Five (5) Years Of Experience Implementing The Paver™ Pavement Management System. provide Resumes For A Minimum Of Two (2) Civil Engineers. Civil Engineers Should Have A Minimum Of Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Civil Engineers Should Have A Thorough Knowledge Of The Paver™ Software And Paver™ Pavement Management System And Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. Civil Engineers Should Be A U.s. Registered Professional Engineer. List Recent Paver™ Software Training Attended. provide Resumes For A Minimum Of Two (2) Engineering Technicians. Engineering Technicians Should Have At Least Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Engineer Technicians Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Knowledge And Experience Using The Paver™ Software Is Desirable. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. List Recent Paver™ Software Training Attended. provide Resume For A Minimum Of One (1) Gis Technician. Gis Technician Should Have At Least One (1) Year Of Experience Creating/updating Paver™ Gis Network Shapefiles. c. Past Performance. Past Performance On Dod And Other Contracts With Respect To The Quality Of Work And Compliance With Performance Schedules, As Determined By Cpars And Other Sources. Submit Entire Cpars Evaluations, Not Summaries Of Ratings. Provide Cpars For The 4 Projects Identified In Section I Only. Provide Ppq In The Event That Cpars Does Not Exist. Firms Which Choose To Use The Ppq May Obtain A Ppq Standard Form By Submitting A Request To The Below Referenced Poc Via Email. d. Proposed Management Plan. A Proposed Management Plan Shall Be Presented That Includes An Organization Chart (reference Sf330, Part I, Section D) And Addresses Team Organization (reference Sf330, Part I, Section C), Any Anticipated Sub-contractors Or Entities To Supplement The Design Team, Quality Control Procedures, Cost Control, Coordination Of In-house Disciplines And Consultants Required To Meet Work Capacity. Organizational Chart Should Clearly Indicate Available Inspection Teams. the Sf 330 Shall Clearly Indicate The Primary Office Where The Work Will Be Performed And The Staffing At That Office. (sf 330, Part I, Section H, Item 2). 4. Submission Requirements: Interested Firms Having The Capabilities To Perform This Work Must Submit Electronically One (1) Copy Of The Sf 330 Part I, And One (1) Copy Of Sf 330 Part Ii For The Prime Firm And All Consultants/subcontractors, To The Following Recipients With Subject Line “fort Campbell Paver Synopsis Response” Not Later Than 2:00 Pm Central Standard Time (cst) On The Response Date Indicated In This Announcement: brandon Landis, Brandon.p.landis@usace.army.mil amanda Eaton, Amanda.e.eaton@usace.army.mil for File Sizes Greater Than 20 Megabytes (mb) The Firm Shall Break The File Into Smaller Files Sent Via Separate Emails With Each Email Marked To Identify Which Number The Email Is Relative To The Total Number Of Emails Submitted (i.e. “email 1 Of 2”). Once All Emails Submitted Have Been Received The Government Will Confirm Receipt Via Responsive Email. Regulation Requires That The Selection Board Not Consider Any Submittals Received After The Specified Time And Date. Late Proposal Rules In Far 15.208 Will Be Followed For Submittals Received After 2:00pm Central Time On The Closing Date Specified In This Announcement. The Sf 330, 3/2013 Edition, Must Be Used, And May Be Obtained From The Following Web Site: Http://www.gsa.gov/portal/forms/download/116486. Include Duns Number And Cage Code In Sf330 Part I, Section B, Block 5. Additionally, The Duns Number And Cage Code Should Be Identified In Sf 330 Part I, Section C, Block 9, For Each Team Member. The Submittal Shall Have A Page Limit Of 50 Pages (total Of 50 Pages Allowed For Complete Copy Of The Submittal, All-inclusive). The Selection Board Will Not Evaluate Beyond 50 Pages. A Page Is One Side Of A Sheet. Blank Sheets/tabs Separating The Sections Within The Sf 330 Will Not Count Against The Maximum Page Count. All Fonts Shall Be At Least 10 Pitch Or Larger And Have Text Of Arial, Times New Roman, Or Calibri. Pages Shall Be 8-1/2 Inches By 11 Inches. Margins Should Be No Less Than 1” (right, Left, Top, And Bottom). An Sf 330 Part Ii Is Required For Each Branch Office Of The Prime Firm And Any Consultants/subcontractors That Will Have A Key Role In The Proposed Contract (i.e. A Part Ii Is Required For All Entities Identified In Sf 330 Part I, Section C Of The Submittal). Cover Letters, Company Literature And Extraneous Materials Are Not Desired And Will Not Be Considered. Sections E And G Of Sf 330 Part I Must Include Only Individuals Proposed To Perform The Anticipated Work, Including All Consultants/subcontractors. In Sf 330 Part I, Section G, Block 26, Along With The Name, Include The Firm With Which The Person Is Associated. A Maximum Of Four (4) Projects Including The Prime And Consultants/subcontractors Will Be Reviewed For Sf 330 Part I, Section F. If More Than 4 Projects Are Submitted, Only The First 4 Projects Will Be Evaluated. Use No More Than Two (2) Pages Per Project. When Listing Projects In Sf 330 Part 1, Section F, An Indefinite Delivery Contract (idc) With Multiple Task Orders As Examples Is Not Considered A Project. A Task Order Executed Under An Idc Contract Is A Project. Past Performance Evaluations (cpars/acass, Ppq – Reference Paragraph 3.d. Above) Shall Be Submitted For Each Project Provided In Sf 330, Part I, Section F. Sf 330, Part I, Section H (additional Information) Shall Contain The Following Information. Sf 330, Part I, Section H (additional Information) Shall Contain The Information In Paragraph 3.d Above Regarding Management Plan. joint Ventures Shall Submit The Following Additional Documentation Of The Evidence Of A Joint Venture Entity: 1) Firms Shall Provide A Copy Of A Legally Binding Joint Venture Agreement, And 2) Identification Of The Party Who Can Legally Bind The Joint Venture. a Draft Solicitation Is Provided With This Announcement. The Purpose Of This Draft Solicitation Is For Industry To Be Able To Review The Provisions, Clauses, Terms, And Conditions. This Is Not A Request For Proposal. A Price Proposal Is Not Requested With This Announcement. The Corps Will Review Contractor Qualifications And Select The Most Highly Qualified Firm. That Firm Will Receive The Solicitation And A Proposal Will Be Requested And Negotiated With That Firm. all Questions Shall Be Submitted Via The Bidder Inquiry Portal In Projnet At Http://www.projnet.org/projnet. Questions Should Be Submitted No Later Than 25 March 2024 At 2:00 P.m. Central Time To Allow Time For A Response. On This Date And Time The Portal Will Be Closed. For Questions, No Other Means Of Communication, E-mail, Fax, Or Telephone Will Be Accepted. To Submit And Review Inquiry Items, Prospective Vendors Will Need To Use The Bidder Inquiry Key Presented Below And Follow The Instructions Listed Below. A Prospective Vendor Who Submits A Comment/question Will Receive An Acknowledgement Of Their Comment/question Via Email, Followed By An Answer To The Comment/question After It Has Been Processed By Our Team. All Timely Questions And Approved Answers Will Be Made Available Through Projnet. To Submit And Review Inquiries, Firms Will Need To Be Current Registered Users Of The Projnet System. registration For Projnet Bidder Inquiry Access (if You Are Already Registered, Go To Entering Bidder Inquiries In Projnet Bidder Inquiry System Below.) 1. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 2. Identify The Agency. This Should Be Marked As Usace. 3. Key. Enter The Bidder Inquiry Key Listed Below. 4. Email. Enter The Email Address You Would Like To Use For Communication. 5. Click Continue. A Page Will Then Open Saying That A User Account Was Not Found And Will Ask You To Create One Using The Provided Form. 6. Enter Your First Name, Last Name, Company, City, State, Phone, Email, Secret Question, Secret Answer, And Time Zone. Make Sure To Remember Your Secret Question And Answer As They Will Be Used From This Point On To Access The Projnet System. 7. Click Add User. Once This Is Completed You Are Now Registered Within Projnet And Are Currently Logged Into The System. entering Bidder Inquiries In Projnet Bidder Inquiry System 1. For Future Access To Projnet, You Will Not Be Emailed Any Type Of Password. You Will Utilize Your Secret Question And Secret Answer To Log In. 2. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 3. Identify The Agency. This Should Be Marked As Usace. 4. Key. Enter The Bidder Inquiry Key Listed Below. 5. Email. Enter The Email Address You Used To Register Previously In Projnet. 6. Click Continue. A Page Will Then Open Asking You To Enter The Answer To Your Secret Question. 7. Enter Your Secret Answer And Click Login. Once This Is Completed You Are Now Logged Into The System. 8. Follow Online Screen Instructions To Enter Specific Bidder Inquiries For The Project. the Solicitation Number Is: W9128f-24-r-0017 the Bidder Inquiry Key Is: Q5emar-rhtx9q firms Are Requested To Review The Bidder Inquiry Portal For Previous Questions And Responses, Prior To Submission Of A New Inquiry In The Portal. Caution: Any Inquiry Submitted And Answered Within This System Will Be Accessible To View By All Interested Firms On This Solicitation. The Call Center For The Projnet Operates Weekdays From 8 Am To 5 Pm U.s. Central Time Zone. The Telephone Number Is 1-800-428-help. 5. Place Of Contract Performance: as Noted Above Service Contract Act Wage Decisions Will Be Applicable To Both The Project Site, Fort Campbell, Kentucky, And The Awardee’s Home Office (this Wage Decision Will Be Provided At Award).
DEPT OF THE ARMY USA Tender
Consultancy Services
United States
Closing Date24 Jul 2024
Tender AmountRefer Documents
Details: Synopsis Of A-e Services road And Parking Pavement Condition Inspection And Paver Management System Update Defense Supply Center Columbus, Oh classification Code: Service Code C (architect And Engineering Services) subject: Road And Parking Pavement Condition Inspection And Paver Management System Update Defense Supply Center Columbus, Oh description: 1. Contract Information. this Solicitation Is Restricted To Small Business Participation the North American Industry Classification System (naics) Is 541330 – Engineering Services And Small Business Size Standard Is $25.5m. this Contract Is Being Procured In Accordance With The Brooks A-e Act As Implemented In Far Subpart 36.6. Firms Will Be Selected For Negotiation Based On Demonstrated Competence And Qualifications For The Required Work. contract Type: This Will Be A Single Firm Fixed Price (ffp) Purchase Order. performance Period: Twelve Months After Purchase Order Award. Estimated Start And Completion Dates Of All Work Is July 2024 And July 2025, Respectively. options: There Are No Options Included In This Contract. range Of Estimated A&e Price: Under Simplified Acquisition Threshold (sat), Under $250,000. subcontracting Plan: Not Required. this Contract Is Subject To The Service Contract Labor Standards And The Current Service Contract Act Wage Decision (sca Wd) For The Location Of Work Has Been Attached. The Sca Wd For The Awardee’s Home Office Will Be Applicable And Included At Award. all Interested Vendors Are Required To Be Registered In Sam.gov With A Valid Commercial And Government Entity Program (cage) Code And Unique Entity Identifier (uei). 2. Project Information. a-e Services Shall Include Pavement Inspection Utilizing Paver™ Version 7.1.2 Or Higher Located At Columbus, Oh. Work Shall Be Accomplished In Accordance With Astm D6433 (20 Or Later) With Exception To The Sampling Rate As Identified In The Scope Of Work (see Attachments). reference The Scope Of Work For Additional Information Regarding Qualifications Of Personnel, Coordination, Permitting, Field Surveying, Scheduling, Submittals, Government Ownership, Antiterrorism And Security Provisions, Major Requirements, Modeling, Analysis, 10-year Working Analysis, Project Development, Meetings, Isr Reporting, Draft And Final Reporting, Quality Assurance, Deliverables, And Points Of Contact. 3. Selection Criteria: The Selection Criteria For This Project Are Listed Below In Descending Order Of Importance. a. Specialized Experience And Technical Competence: Submittals Shall Demonstrate The Specialized Experience And Technical Competence To Execute The Types Of Projects And Activities As Indicated Above In Paragraph 2, Project Information. Experience Implementing The Paver™ Pavement Management System Using The Paver™ Software Version 6 Or Newer (paver™ 7 Experience Is Preferred) And Manual Pavement Distress Data Collection. Submit No More Than Four (4) Examples Of Paver™ Implementation Projects Using The Paver™ Software And Pavement Management System And Manual Distress Data Collection. Example Projects Should Be Submitted For Roads And Parking Only. Paver™ Implementation Experience On Army Or Air Force Installations Is Desirable But Not Essential. Only Relatable Experience That Has Occurred In The Last Five Years Should Be Included In The Submittal. Project Examples Submitted Should Be Of Completed Projects. All Projects Cited Shall Identify Start/complete Dates, Project Size (pavement Area, Cost And Scope) And Tasks Performed. In Addition To The Example Projects Above, Include A List (sf 330, Part I, Section H) Of Any Other Paver™ Implementations Using Manual Pavement Distress Data Collection Completed Within The Last Five Years Including Location, Customer, Pavement Type (roads, Parking Areas, Airfields, Etc.) And Area Of Pavement Inspected. (sf 330, Part I, Section F) b. Professional Qualifications: Firms Shall Demonstrate Professional Personnel Qualifications And Specialized Experience For Key Disciplines. Evaluation Of Professional Qualifications Will Consider Education, Training, Relevant Experience And Longevity With The Firm. Experience Working On Applicable Army And Air Force Projects Is Desirable And Should Be Identified. (sf 330, Part I, Sections E & G). provide Resumes For A Minimum Of One (1) Project Manager (team Leader), Project Managers Should Be A U.s. Registered Professional Engineer And Have At Least Five (5) Years Of Experience Implementing The Paver™ Pavement Management System. provide Resumes For A Minimum Of Two (2) Civil Engineers. Civil Engineers Should Have A Minimum Of Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Civil Engineers Should Have A Thorough Knowledge Of The Paver™ Software And Paver™ Pavement Management System And Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. Civil Engineers Should Be A U.s. Registered Professional Engineer. List Recent Paver™ Software Training Attended. provide Resumes For A Minimum Of Two (2) Engineering Technicians. Engineering Technicians Should Have At Least Three (3) Years Of Experience Implementing The Paver™ Pavement Management System. Engineer Technicians Should Have Several Years Of Experience Identifying Pavement Distresses In Accordance With Astm D6433. Knowledge And Experience Using The Paver™ Software Is Desirable. Experience Creating Pci And M&r Family Models, Performing Condition Analysis, And Performing M&r Work Planning Should Be Indicated. List Recent Paver™ Software Training Attended. provide Resume For A Minimum Of One (1) Gis Technician. Gis Technician Should Have At Least One (1) Year Of Experience Creating/updating Paver™ Gis Network Shapefiles. c. Past Performance. Past Performance On Dod And Other Contracts With Respect To The Quality Of Work And Compliance With Performance Schedules, As Determined By Cpars And Other Sources. Submit Entire Cpars Evaluations, Not Summaries Of Ratings. Provide Cpars For The 4 Projects Identified In Section I Only. Provide Ppq In The Event That Cpars Does Not Exist. Firms Which Choose To Use The Ppq May Obtain A Ppq In The Attachments Section Of This Sam Posting. If Issues Arise, A Ppq Form Can Be Obtained By Submitting A Request To The Below Referenced Poc Via Email. d. Proposed Management Plan. A Proposed Management Plan Shall Be Presented That Includes An Organization Chart (reference Sf330, Part I, Section D) And Addresses Team Organization (reference Sf330, Part I, Section C), Any Anticipated Sub-contractors Or Entities To Supplement The Design Team, Quality Control Procedures, Cost Control, Coordination Of In-house Disciplines And Consultants Required To Meet Work Capacity. Organizational Chart Should Clearly Indicate Available Inspection Teams. the Sf 330 Shall Clearly Indicate The Primary Office Where The Work Will Be Performed And The Staffing At That Office. (sf 330, Part I, Section H, Item 2). 4. Submission Requirements: In An Effort To Reduce Paper And Cost, All Proposals Shall Be submitted Electronically. All Submissions Will Be In Adobe Pdf Format With Optical Character Recognition (ocr) Applied To All Documents That Will Enable Word Searches To Be Conducted Using Adobe- Compatible Pdf Software. The Two (2) Sf330s Listed Below Shall Be Submitted As Separate Files Via Email. Offerors Should Follow Controlled Unclassified Information (cui) Guidelines And Use Proper Markings If Submitting Documents That Are Considered Cui. Proper Markings Include The Following: Banner Markings Should Appear Above The Email Text Containing Cui, The Email Subject Line Should Also Indicate The Email Contains Cui, And File Names For Any Attachments Containing Cui. Offerors May Use Or Pkzip To Reduce File Size And Facilitate Transmission. offerors Are Encouraged To Send Both Files In The Same Email Transmission, If Possible. interested Firms Having The Capabilities To Perform This Work Must Submit Electronically One (1) Copy Of The Sf 330 Part I, And One (1) Copy Of Sf 330 Part Ii For The Prime Firm And All Consultants/subcontractors, To The Following (3) Three Recipients With Subject Line “13030 Dscc Paver” Not Later Than 2:00 Pm Mountain Time (mt) On The Response Date Indicated In This Announcement: 1. Kelly Hopper; Kelly.c.hopper@usace.army.mil 2. Jessica Beckman; Jessica.l.merrill2@usace.army.mil 3. Cenwo Ct Fsrm Doc Submission; Cenwo-ct-fsrm-doc-submission@usace.army.mil for File Sizes Greater Than 20 Megabytes (mb) The Firm Shall Break The File Into Smaller Files Sent Via Separate Emails With Each Email Marked To Identify Which Number The Email Is Relative To The Total Number Of Emails Submitted (i.e. “email 1 Of 2”). Once All Emails Submitted Have Been Received The Government Will Confirm Receipt Via Responsive Email. for The Purposes Of Determining Whether The Proposal Was Received “late” In Accordance With Far 15.208, The Date And Time (mountain Time) The File(s) Are Received Via Email Will Be The Date And Time (mountain Time) The Government Received The Proposal. Do Not Assume That Electronic Communication Is Instantaneous. Please Make Allowances For Delays In Transmittal. The Government Is Not Responsible For Proposals Delivered To Any Location Or To Anyone Other Than Those Designated To Receive Proposals On Its Behalf. The Offeror Is Responsible For Ensuring That The Proposal Is Submitted So As To Reach The Designated Recipient And Is Responsible For Allowing Sufficient Time For The Proposal To Be Received In Accordance With The Information Provided. Failure To Submit A Complete Proposal Iaw Instructions And Requirements May Result In The Entire Offer Being Rejected. sf 330, 07/2021 Edition, Must Be Used, And May Be Obtained From The Following Website: https://www.gsa.gov/reference/forms/architectengineer-qualifications. Include Sam Uei Number And Cage Code In Sf330 Part I, Section B, Block 5. Additionally, The Sam Uei Number And Cage Code Should Be Identified In Sf 330 Part I, Section C, Block 9, For Each Team Member. the Submittal Shall Have A Page Limit Of 50 Pages (total Of 50 Pages Allowed For Complete Copy Of The Submittal, All-inclusive). The Selection Board Will Not Evaluate Beyond 50 Pages. A Page Is One Side Of A Sheet. Blank Sheets/tabs Separating The Sections Within The Sf 330 Will Not Count Against The Maximum Page Count. All Fonts Shall Be At Least 10 Pitch Or Larger And Have Text Of Arial, Times New Roman, Or Calibri. Pages Shall Be 8-1/2 Inches By 11 Inches. Margins Should Be No Less Than 1” (right, Left, Top, And Bottom). An Sf 330 Part Ii Is Required For Each Branch Office Of The Prime Firm And Any Consultants/subcontractors That Will Have A Key Role In The Proposed Contract (i.e. A Part Ii Is Required For All Entities Identified In Sf 330 Part I, Section C Of The Submittal). Cover Letters, Company Literature And Extraneous Materials Are Not Desired And Will Not Be Considered. Sections E And G Of Sf 330 Part I Must Include Only Individuals Proposed To Perform The Anticipated Work, Including All Consultants/subcontractors. In Sf 330 Part I, Section G, Block 26, Along With The Name, Include The Firm With Which The Person Is Associated. A Maximum Of Four (4) Projects Including The Prime And Consultants/subcontractors Will Be Reviewed For Sf 330 Part I, Section F. If More Than 4 Projects Are Submitted, Only The First 4 Projects Will Be Evaluated. Use No More Than Two (2) Pages Per Project. When Listing Projects In Sf 330 Part 1, Section F, An Indefinite Delivery Contract (idc) With Multiple Task Orders As Examples Is Not Considered A Project. A Task Order Executed Under An Idc Contract Is A Project. Past Performance Evaluations (cpars/acass, Ppq – Reference Paragraph 3.d. Above) Shall Be Submitted For Each Project Provided In Sf 330, Part I, Section F. Sf 330, Part I, Section H (additional Information) Shall Contain The Following Information. Sf 330, Part I, Section H (additional Information) Shall Contain The Information In Paragraph 3.d Above Regarding Management Plan. joint Ventures Shall Submit The Following Additional Documentation Of The Evidence Of A Joint Venture Entity: 1) Firms Shall Provide A Copy Of A Legally Binding Joint Venture Agreement, And 2) Identification Of The Party Who Can Legally Bind The Joint Venture. a Draft Solicitation Is Provided With This Announcement. The Purpose Of This Draft Solicitation Is For Industry To Be Able To Review The Provisions, Clauses, Terms, And Conditions. This Is Not A Request For Proposal. A Price Proposal Is Not Requested With This Announcement. The Corps Will Review Contractor Qualifications And Select The Most Highly Qualified Firm. That Firm Will Receive The Solicitation And A Proposal Will Be Requested And Negotiated With That Firm. all Questions Shall Be Submitted Via The Bidder Inquiry Portal In Projnet At Http://www.projnet.org/projnet. Questions Should Be Submitted No Later Than 15 Jul 2024 At 2:00 P.m. Mountain Time To Allow Time For A Response. On This Date And Time The Portal Will Be Closed. For Questions, No Other Means Of Communication, E-mail, Fax, Or Telephone Will Be Accepted. To Submit And Review Inquiry Items, Prospective Vendors Will Need To Use The Bidder Inquiry Key Presented Below And Follow The Instructions Listed Below. A Prospective Vendor Who Submits A Comment/question Will Receive An Acknowledgement Of Their Comment/question Via Email, Followed By An Answer To The Comment/question After It Has Been Processed By Our Team. All Timely Questions And Approved Answers Will Be Made Available Through Projnet. To Submit And Review Inquiries, Firms Will Need To Be Current Registered Users Of The Projnet System. registration For Projnet Bidder Inquiry Access (if You Are Already Registered, Go To Entering Bidder Inquiries In Projnet Bidder Inquiry System Below.) 1. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 2. Identify The Agency. This Should Be Marked As Usace. 3. Key. Enter The Bidder Inquiry Key Listed Below. 4. Email. Enter The Email Address You Would Like To Use For Communication. 5. Click Continue. A Page Will Then Open Saying That A User Account Was Not Found And Will Ask You To Create One Using The Provided Form. 6. Enter Your First Name, Last Name, Company, City, State, Phone, Email, Secret Question, Secret Answer, And Time Zone. Make Sure To Remember Your Secret Question And Answer As They Will Be Used From This Point On To Access The Projnet System. 7. Click Add User. Once This Is Completed You Are Now Registered Within Projnet And Are Currently Logged Into The System. entering Bidder Inquiries In Projnet Bidder Inquiry System 1. For Future Access To Projnet, You Will Not Be Emailed Any Type Of Password. You Will Utilize Your Secret Question And Secret Answer To Log In. 2. From The Projnet Home Page Link Above, Click On Quick Add On The Upper Right Side Of The Screen. 3. Identify The Agency. This Should Be Marked As Usace. 4. Key. Enter The Bidder Inquiry Key Listed Below. 5. Email. Enter The Email Address You Used To Register Previously In Projnet. 6. Click Continue. A Page Will Then Open Asking You To Enter The Answer To Your Secret Question. 7. Enter Your Secret Answer And Click Login. Once This Is Completed You Are Now Logged Into The System. 8. Follow Online Screen Instructions To Enter Specific Bidder Inquiries For The Project. the Solicitation Number Is: W9128f-24-r-0072 the Bidder Inquiry Key Is: Rny924-jyi4cw firms Are Requested To Review The Bidder Inquiry Portal For Previous Questions And Responses, Prior To Submission Of A New Inquiry In The Portal. Caution: Any Inquiry Submitted And Answered Within This System Will Be Accessible To View By All Interested Firms On This Solicitation. The Call Center For The Projnet Operates Weekdays From 8 Am To 5 Pm U.s. Central Time Zone. The Telephone Number Is 1-800-428-help. 5. Place Of Contract Performance: as Noted Above Service Contract Act Wage Decisions Will Be Applicable To Both The Project Site, Columbus, Oh And The Awardee’s Home Office (this Wage Decision Will Be Provided At Award).
Department Of Health Region Xii Tender
Software and IT Solutions
Philippines
Closing Date29 Apr 2024
Tender AmountPHP 149.9 K (USD 2.5 K)
Details: Description Ipad Computer - 256gb, Display: Liquid Retina Display: - 10.9-inch (diagonal) Ledbacklit Multitouch Display With Ips Technology - 2360-by-1640-pixel Resolution At 264 Pixels Per Inch (ppi) Chip: - M1 Chip - 8-core Cpu With 4 Performance Cores And 4 Efficiency Cores - 8-core Gpu - 16-core Neural Engine - 8gb Ram - 256 Gb Storage Camera - 12mp Wide Camera, Ƒ/1.8 Aperture - Digital Zoom Up To 5x - Five-element Lens - Autofocus With Focus Pixels - Panorama (up To 63mp) - Smart Hdr 3 Video Recording - 4k Video Recording At 24 Fps, 25 Fps, 30 Fps, Or 60 Fps - 1080p Hd Video Recording At 25 Fps, 30 Fps, Or 60 Fps - 720p Hd Video Recording At 30 Fps - Slomo Video Support For 1080p At 120 Fps Or 240 Fps Front Camera - 12mp Ultra Wide Front Camera, 122° Field Of View - Ƒ/2.4 Aperture - Smart Hdr 3 - 1080p Hd Video Recording At 25 Fps, 30 Fps, Or 60 Fps Video Calling 3 - Facetime Video - Center Stage Audio Calling - Facetime Audio Speakers - Stereo Speakers Microphones - Dual Microphones For Calls, Video Recording, And Audio Recording Wireless - All Models - Wi-fi 6 (802.11ax) With 2x2 Mimo; Speeds Up To 1.2 Gbps - Simultaneous Dual Band - Bluetooth 5.0 - Wi-fi Sensors - Touch Id - Three‐axis Gyro - Accelerometer - Barometer - Unlock Ipad - Secure Personal Data Within Apps Display Support - Supports Full Native Resolution On The Built-in Display At Millions Of Colors - Supports One External Display With Up To 6k Resolution At 60hz - Digital Video Output - Native Displayport Output Over Usbc - Vga, Hdmi, And Dvi Output Supported Using Adapters (sold Separately) - Video Mirroring Power And Battery - All Models - Built‐in 28.6‐watt‐hour Rechargeable Lithiumpolymer Battery - Up To 10 Hours Of Surfing The Web On Wi‐fi Or Watching Video - Charging Via Power Adapter Or Usbc To Computer System - Wi-fi + Cellular Models - Up To 9 Hours Of Surfing The Web Using Cellular Data Network Operating System - Ipados With Keyboard - Magic Keyboard
Department Of Health Region Xii Tender
Philippines
Closing Date27 Aug 2024
Tender AmountPHP 99.9 K (USD 1.7 K)
Details: Description Ipad Computer - 256gb, Display: Liquid Retina Display: - 10.9-inch (diagonal) Ledbacklit Multitouch Display With Ips Technology - 2360-by-1640-pixel Resolution At 264 Pixels Per Inch (ppi) Chip: - M1 Chip - 8-core Cpu With 4 Performance Cores And 4 Efficiency Cores - 8-core Gpu - 16-core Neural Engine - 8gb Ram - 256 Gb Storage Camera - 12mp Wide Camera, Ƒ/1.8 Aperture - Digital Zoom Up To 5x - Five-element Lens - Autofocus With Focus Pixels - Panorama (up To 63mp) - Smart Hdr 3 Video Recording - 4k Video Recording At 24 Fps, 25 Fps, 30 Fps, Or 60 Fps - 1080p Hd Video Recording At 25 Fps, 30 Fps, Or 60 Fps - 720p Hd Video Recording At 30 Fps - Slomo Video Support For 1080p At 120 Fps Or 240 Fps Front Camera - 12mp Ultra Wide Front Camera, 122° Field Of View - Ƒ/2.4 Aperture - Smart Hdr 3 - 1080p Hd Video Recording At 25 Fps, 30 Fps, Or 60 Fps Video Calling 3 - Facetime Video - Center Stage Audio Calling - Facetime Audio Speakers - Stereo Speakers Microphones - Dual Microphones For Calls, Video Recording, And Audio Recording Wireless - All Models - Wi-fi 6 (802.11ax) With 2x2 Mimo; Speeds Up To 1.2 Gbps - Simultaneous Dual Band - Bluetooth 5.0 - Wi-fi Sensors - Touch Id - Three‐axis Gyro - Accelerometer - Barometer - Unlock Ipad - Secure Personal Data Within Apps Display Support - Supports Full Native Resolution On The Built-in Display At Millions Of Colors - Supports One External Display With Up To 6k Resolution At 60hz - Digital Video Output - Native Displayport Output Over Usbc - Vga, Hdmi, And Dvi Output Supported Using Adapters (sold Separately) - Video Mirroring Power And Battery - All Models - Built‐in 28.6‐watt‐hour Rechargeable Lithiumpolymer Battery - Up To 10 Hours Of Surfing The Web On Wi‐fi Or Watching Video - Charging Via Power Adapter Or Usbc To Computer System Operating System - Ipados
DEPT OF THE AIR FORCE USA Tender
Software and IT Solutions...+1Security and Emergency Services
United States
Closing Date5 Aug 2024
Tender AmountRefer Documents
Details: The Space Development Agency (sda) Issued A Request For Proposal (rfp) For The Advanced Fire Control Ground Infrastructure (afcgi) Acquisition. the Space Development Agency (sda) Issued This Request For Proposal (rfp) For The Services Of A Ground Segment Infrastructure Provider For Sda’s Advanced Fire Control (afc) Program. The Afc Program Will Deliver Integrated Space And Ground Elements To Demonstrate Advanced Fire Control Missions. Afc Executes Operationally Relevant Prototypes To Demonstrate Proof Of Scalability, Show Military Utility, And Provide A Pathfinder For Future Proliferation Of Afc Capabilities. the Afc Ground Segment Acquisition, Referred To As Afcgi, Is A Component Of The Broader Afc Program. The Objective Of Afcgi Is To Provide Common Ground Infrastructure And Resources To Minimize Cost And Complexity For Multiple Afc Prototype Programs. The Efforts Of The Afcgi Acquisition Will Be Central To The Successful Execution Of The Fire-control On Orbit-support To The Warfighter (foo Fighter Or F2) Prototype System (launching In Q1fy27) And Follow-on Fire Control Demonstration Programs. the Afcgi Contractor Will: deliver And Manage Ground Segment Resources, Including But Not Limited To Ground Entry Points (geps) And Terrestrial Network Connections, fit-out And Manage A Government-owned, Contractor-operated (goco) Facility Called The Demonstration Operations Center (doc), manage A Government-procured, Contractor-operated Cloud Environment To Provide Cloud Services, Including But Not Limited To Hosting Space Vehicle Mission Operations Center Software, Data Archiving, Enabling Remote Access To Data During On-orbit Demonstrations, Enabling Data Processing And Analysis, Hosting Mission Partner Software, And Interfacing With Mission Partner Systems; And, provide Program Management, Systems Engineering, Integration, Verification, And Operations And Maintenance Of The Afc Ground Infrastructure. to Receive Additional Controlled Unclassified Information (cui) Documents, Please Send An Email Including Your Cage Code And Facility Location To Ussf.pentagon.sda.mbx.fa240124r0001@mail.mil With The Subject Line “sda Advanced Fire Control Ground Infrastructure (afcgi) Content Request”. Requests For Cui Data Must Be Received No Later Than 19 July 2024 At Noon Et. amendment 1 amendment 1 Makes The Following Updates: updates The Sda Doc Notional Floor Plan In The Bidder's Library provides Government Answers To Contractor Questions updates The Sow: section 1.6 Compliance Table To Reflect Current Data Of Ssaa section 3.6.005 To Include “and Monitors” amendment 2 amendment 2 Updates The Government Answers To Contractor Questions.
861-870 of 904 archived Tenders