Cable Tenders
Cable Tenders
DEPT OF THE NAVY USA Tender
Aerospace and Defence
United States
Closing Date6 Jan 2025
Tender AmountRefer Documents
Details: This Was Previously Posted As N0016424snb66 n00164-25-s-nb20 – Request For Information – Test, Evaluation, Repair, Modification & Upgrade Of Electronic Warfare Systems, Psc: J059, Naics 811210 issue Date: 4 December 2024 Closing Date: 6 January 2024 - 3:00 Pm Edt this Synopsis Is Being Posted To The Sam.gov Contract Opportunities Page Located At Https://sam.gov/content/opportunities. Sam.gov Contract Opportunities Is The Single Point Of Entry For Posting Of Synopsis And Solicitations To The Internet. Please Feel Free To Use This Site To Access Information Posted By Nswc Crane. request For Information (rfi) / Sources Sought - The Government Is Issuing This Rfi/sources Sought Announcement As Part Of A Market Research Effort On Behalf Of Crane Division, Naval Surface Warfare Center (nswc Crane) And Is Seeking Information For Market Research Purposes Relative To Capabilities Available To Support The Test, Evaluation, Repair, Modification, And Upgrade Of Prime Mission Equipment Weapon Replaceable Assemblies (wras), Shop Replaceable Assemblies (sras), And Components Utilized In Electronic Warfare Systems Associated With The Ea-18g Growler And P-8a Poseidon Aircraft, As Well As Other Related Platforms. the Purpose And Objective Of This Announcement Is To Find Highly Qualified Repair And Testing Facilities With Expertise In The Following Areas: testing And Repair Of Radio Frequency (rf), Digital, Analog Assemblies And Ac/dc Power Supplies Utilizing Manual And Automated Test Stations. repair Of Chassis Assemblies, Wiring Harnesses, Harness Fabrication And Re-wiring And Testing Chassis Assemblies. component Replacement On Weapons Repairable Assemblies (wras) And Shop Replaceable Assemblies (sras) Utilizing Approved Soldering Procedures And Equipment (to Include Surface Mount, Thru-hole, Wiring, Connector Replacement, Etc.). maintain, Calibrate, Repair, Modify Vendor/government Provided Manual & Automated Test Equipment To Ensure Continued Operational Use performing Prime Mission And Peculiar Support Equipment System Modification And Upgrades Per Provided Procedures. evaluation, Rebuild And Testing Of Various Rf Waveguide And Antenna Assemblies. utilize Vendor/government Provided Test Equipment To Conduct Repairs Of Radio Frequency (rf), Digital, And Analog Assemblies; Ac/dc Power Supplies; And Rf Waveguide And Antenna Assemblies. cable Manufacturing, Including Radio Frequency (rf) Lines, Interface Devices And/or Wiring Harness Assemblies. additionally, The Purpose Of This Announcement Is To Receive Feedback From Industry On Specific Market Research Questions, In Order To Support A Potential Procurement Associated With The Test, Evaluation, Repair, Modification, And Upgrade Of Electronic Warfare Systems. interested Parties Are Strongly Encouraged To Submit An Initial Synopsis (commonly Referred To As “white Paper”). This White Paper Should Not Exceed 20 Pages Written (times New Roman, 12 Font) Or Ms Powerpoint Slides, (excluding Supporting Information Such As Commercial Literature, Catalogues, Manuals, Vendor’s Current Equipment List, Responses To Government’s Market Research Questions, Etc.), With An Executive Summary (one Page Or Less) On Their Capabilities, As Well As Responses To The Government’s Market Research Questions (noted In Attachment 1 To This Rfi). A Draft Statement Of Work And Sow Appendix A Is Provided To Aid Interested Sources In Understanding The Scope Of Work That May Be Executed Under This Potential Procurement. the Closing Date For Receipt Of Comments/submission Of “white Papers” On This Rfi Is 6 January 2024. contractors Must Be Properly Registered In The Government System For Award Management Database (sam). Contractors May Obtain Information On Sam Registration And Annual Confirmation Of Requirements By Calling 1-866-606-8220, Or Via The Internet At Www.sam.gov. this Announcement Does Not Constitute An Invitation For Bids (ifb), A Request For Quote (rfq), Or A Request For Proposal (rfp) And It Should Not Be Construed As A Commitment Of Any Kind By The Government To Issue A Formal Solicitation Or Ultimately Award A Contract. The U. S. Government Is In No Way Liable To Pay For Or Reimburse Any Companies Or Entities That Respond To This Announcement. Any Costs Incurred By Interested Companies In Response To This Announcement Will Not Be Reimbursed. Any Information Provided That Is Marked As Proprietary Information Will Be Safeguarded To Prevent Disclosures To Non-government Personnel And Entities. The Government May Elect To Visit, Or Host A Visit, From Any Potential Sources Following The Market Survey. Your Interest In This Program Is Appreciated. your Interest In This Program Is Appreciated. responses From Small And Small Disadvantaged Business Firms Are Highly Encouraged. Firms Responding Should Indicate If They Are A Small Business, A Socially And Economically Disadvantaged Business, 8(a) Firms, Historically Black Colleges Or Universities, And Minority Institutions. responses To The Rfi Shall Include The Following: submitter's Name street Address, City, State, Nine (9) Digit Zip Code
point Of Contact (poc)
poc Telephone And Facsimile Numbers announcement Number: N00164-25-s-nb20 all Interested Parties Should Provide The Requested Information Regarding This Announcement No Later Than 1500 Edt On Or Before The Closing Date As Specified At The Beginning Of This Solicitation, At The Naval Surface Warfare Center, Crane Division. White Papers May Be Submitted Any Time Prior To Expiration Of This Announcement. Responses Received After 1500 Edt On The Closing Date May Not Be Considered In The Government's Analyses. all Information Received In Response To This Notice That Is Marked Proprietary Will Be Handled Accordingly. Nswc Crane Makes No Implied Or In Fact Contracts By Issuing This Rfi. Acknowledgement Of Receipt Of Responses Will Not Be Made, Nor Will Respondents Be Notified Of The Nswc Crane’s View Of The Information Received. Do Not Send Any Material That Requires A Non-disclosure Agreement Or Identify Information That Is Business Sensitive. Responses To This Notice Will Not Be Returned. All Information Provided Becomes U.s. Navy Property And Will Not Be Returned. Your Interest In This Response Is Appreciated. electronic Or Hard-copy Submissions Will Be Reviewed If Received By The Closing Date And Time. Electronic Submissions Regarding This Announcement May Be Directed To Mr. Robert Knelly, Phone: (812) 854-2887, E-mail: Robert.g.knelly.civ@us.navy.mil . Hardcopy Submissions Should Be Mailed To The Following: Mr. Robert Knelly, Code Wxsq, Bldg. 3330c, Navsurfwarcendiv Crane, 300 Highway 361, Crane, In 47522-5001. If It Is Urgent, Submissions Can Also Be Directed To Ms. Kathryn Muessig, Phone: (812) 381-7158, E-mail: Kathryn.m.muessig.civ@us.navy.mil. Mailing Address: Code 0242, Bldg. 3373, Navsurfwarcendiv Crane, 300 Highway 361, Crane, In 47522-5001. please Refer To Announcement Number N00164-25-s-nb20 In All Correspondence And Communication.
Bureau Of Jail Management And Penology - BJMP Tender
Others...+1Electrical and Electronics
Philippines
Closing Date6 Jan 2025
Tender AmountPHP 295 K (USD 5 K)
Details: Description Name Of The Procuring Entity: Bureau Of Jail Management And Penology Regional Office Iii (bjmpro-iii) Quotation Number: Bjmpro-iii-103-2024 Project Title: Replacement Of Damage Circuit Breakers And Electrical Wirings At Gapan City Jail-male Dormitory Project Location: Gapan City Jail-male Dormitory Tel/cp No: (045) 305-5819 Request For Quotation Date: December 27, 2024 Company Name: __________________________________ Address: _________________________________________ Please Quote Your Best Offer On The Item/s Listed Below And Submit Your Quotation Duly Signed By The Bidder Or By The Bidder’s Representative Not Later Than January 6, 2025, 9:00 Am In A Sealed Envelope At Logistics Division Bureau Of Jail Management And Penology Regional Office Iii. Failure To Strictly Comply With The Deadline And General Conditions Below Shall Automatically Disqualify The Bidder/s From The Bidding Process. Sgd. Desiree M Jamandron Jail Senior Superintendent Bac Chairperson General Conditions: 1. The Official Request For Quotation Must Be Duly Signed By The Bidder Or By The Authorized Representative. All Entries Must Be Typewritten Or Must Be Legible, If Handwritten. 2. Delivery Period Must Be Within 30 Calendar Days From Receipt Of The Contract By The Winning Bidder. Otherwise, An Applicable Penalty Charge Shall Be Imposed. 3. Warranty Shall Be For A Minimum Period Of Three (3) Months For Expendable Goods And Minimum Of One (1) Year For Non-expendable Goods, Reckoned From The Date Of Acceptance By The Procuring Entity. 4. Bidders Must Bid To All Of The Items In This Request For Quotation, Provided Bids Are Within The Agency Budget Contract (abc) Per Item. 5. Bidders Must Only Use This Request For Quotation Form Available At The Logistics Division Bjmpro-iii Or Downloadable At The Philgeps And Bjmpro-iii Websites. For Each Item, The “bidder’s Specifications Offer,” “quantity,” “unit,” “unit Price,’’ And “total Price” Columns Shall Be Completely Filled Out. Non-compliance And/or Incomplete Data Or Non-filling Up Shall Be Grounds For Disqualification. Also, Offering Alternative Option In Addition To Complying With The Required Specifications Is Considered Non-complying. Entries Such As “do” And “same” Shall Mean That The Bidder Is Offering The Same Specifications As Required, And Shall Be Considered As Having Complied With The Requirements. In Case Of Discrepancy Between “unit Price” And “total Price”, The “unit Price” Shall Prevail And “total Price” Shall Be Corrected. 6. The Bjmpro-iii May Select Or Award The Bidder With The Highest Rated Offer Using Quality Cost Based Evaluation (qcbe). 7. The Highest Rated Bidder (hrb) Shall Be Required To Submit The Following Documentary Requirements Within Three (3) Calendar Days Upon Receipt Of The Notice Of Award: A) Business/mayor’s Permit B) Philgeps Registration Number (platinum) 8. Failure To Submit The Requirements Specified In Item No. 7 Shall Nullify The Award. Name Of The Procuring Entity: Bureau Of Jail Management And Penology Regional Office Iii (bjmpro-iii) Quotation Number: Bjmpro-iii-103-2024 Project Title: Replacement Of Damage Circuit Breakers And Electrical Wirings At Gapan City Jail-male Dormitory Project Location: Gapan City Jail-male Dormitory Tel/cp No: (045) 305-5819 Item No. / Particulars Qty Statement Of Compliance Unit Cost Total Cost I. Electrical Works 1. Wires,cables And Connectors 2.panel Board, Circuit Breakers 1.00 3. Conduit And Fittings 1.00 4. Others 1.00 Total Estimated Project Cost (see Attached File) Total (in Words And In Figures) ______________________________________ _________________________________________________________________ Company Name: ________________________________________________________ Total Approved Budget For The Contract (abc)/estimated Cost = Two Hundred Ninety-five Thousand Pesos (php 295,000.00) Terms Of Payment: Per Accomplishment Of The Bidder End-user: Bjmpro-iii After Having Carefully Read And Accepted Your General Conditions, I/we Quote On The Item/s At Prices Indicated Above With Validity Period Of__ Calendar Days. __________________________________ Signature Over Printed Name __________________________________ Designation/position __________________________________ Company Name __________________________________ Tel. No. / Cellphone No./ E-mail Address
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Machinery and Tools
United States
Closing Date10 Jan 2025
Tender AmountRefer Documents
Details: The Minneapolis Vamc Requires A Temporary Chiller Lease 5 Months Out Of The Year. this Is A Sources Sought Looking For Businesses To Provide The Supplies Listed Below For Market Research Purposes. No Awards Of A Contract Will Be Made From This Announcement.
if You Are A Vendor That Can Provide The Requested Information Above And Required Supplies Described Below With Competitive Pricing, Send Your Information (to Include Your Organization's Unique Entity Identifier Number) With A Description Of Proof Of Capability To: Joey Bloomer, Joseph.bloomer@va.gov, By 1/10/2025 @ 17:00 Cst.
additionally, Please Provide Answers As Appropriate To The Following Questions In The Table Below With Your Response To This Sources Sought. Failure To Respond To The Following Questions May Affect The Acquisition Strategy. 1.
identify Your Organization's Socio-economic Category.
2.
identify If Your Organization Is The Manufacturer Of The Requested Supplies.â if You Are Not The Manufacturer, Identify The Manufacturer Of The Supplies That You Will Provide, Their Socio-economic Category And A Letter Showing That Your Organization Is An Authorized Distributor For The Requested Supplies.â
3.
fill Out The Certificate Under Far Provision 52.225-2(b), Identifying The Item And Its Country Of Origin. ( Https://www.acquisition.gov/far/part-52#far_52_225_2__d3401e52). If The Product Is A Us Domestic End Product, Write In Usa For The Item's Country Of Origin.
4.
state Whether Any Of The Requested Supplies May Be Ordered Against A Government Contract Awarded To Your Organization (e.g Federal Supply Schedule (fss), General Services Administration (gsa), Etc.).
5.
address Whether Your Organization Meets The Requirements Of 13 Cfr 121.406 (b)(1)(i), (b)(1)(ii) And (b)(1)(iii) (https://www.ecfr.gov/current/title-13/chapter-i/part-121/subpart-a/subject-group-ecfr0fca5207262de47/section-121.406#p-121.406(b)).
6.
provide Estimated Shipping And Delivery Information For The Requested Supplies (e.g. Expected Lead Time On Delivery).
â
*if Applicable, Vaar 852.219-76 Va Notice Of Limitations On Subcontracting Certificate Of Compliance For Supplies And Products, Will Apply To The Potential Solicitation If Set-aside For Veteran Owned Small-businesses.* â
*if Applicable, Vaar 852.212-71 Gray Market Items, Will Apply To The Potential Solicitation.*
*if Applicable, Far 52.219-14 Limitations On Subcontracting, Will Apply To The Potential Solicitation If Set-aside For Small-businesses. *
statement Of Work objectives: provide Temporary Cooling For Bldg 222 Until A New Cooling System Can Be Designed And Installed. lease Will Be A 5-month Seasonal Lease. It Will Include A Base Year With Two Additional Option Years. The Va May Elect Not To Exercise Any Or All Option Years. statement Of Work: contractor Will Provide And Deliver The Following Items To Bldg 222, Bloomington Rd., St. Paul, Mn. 55111: 2 Self Contained 10 Ton Chiller Units.
2 Supply Air Flexible Ducts That Are 15 Ft Long By 20 In Diameter.
2 Return Air Flexible Ducts That Are 15 Ft Long By 20 In Diameter. units Will Be Delivered No Later Than May 1st And Picked Up On Or After Sept 30th Of Each Period Of Performance. To Eliminate Shipping Costs, The Unit May Remain At The Minneapolis Vamc In An Inoperable/disconnected Condition, Only If Agreed Upon By The Vendor And Poc. chillers Will Meet The Following Requirements Per Unit: cooling Capacity: 10 Ton Units (130,000 140,000 Btus)
power Requirements: 460 Volt, 3 Phase, 30-35 Amps
air Delivery: 3800 4200 Cfm invoices Will Be Submitted Monthly While In Operation. Total Cost Will Be Divided Into 5 Equal Payments. mvahc Will Provide Power Cables And Disconnects Capable Of Delivering The Correct Voltage/amperage To Operate These Units. contractor Is Responsible For All Maintenance. Contractor Will Respond Within 4 Hours Of Reported Equipment Failure. If Unit Cannot Be Repaired, It Will Be Replaced Within 6 Hours Of Reported Failure.
Cebu Technological University Tender
Machinery and Tools
Philippines
Closing Date3 Jan 2025
Tender AmountPHP 909.1 K (USD 15.6 K)
Details: Description 1. Angle Grinder With Accessories (branded) Specifications: Rated Input Power: 710w Disc Diameter: 100mm Brush Diameter: 100mm 2 Pieces 2. Portable Inverter Arc Welding Machine (branded) Specifications: Power Supply Voltage: 220 – 240v Rated Input Capacity: 28kva Ampere Range: 20 – 450amps 2 Pieces 3. Flip – Up Automatic Welding Helmet Specifications: Changeable Battery Automatic Darkening Welding Filter Variable Shades: 5 – 8 And 9 – 13 2 Pieces 4. Leather Welding Apron 2 Pieces 5. Leather Welding Gloves 2 Pairs 6. Grinding Helmet Specifications: Atleast 200mm High Grinding Visor 4 Pieces 1. Marine Type Plywood (local) 4ft X 8ft X 5mm Type: Type 1 (marine Plywood) 25 Pieces 2. Marine Type Plywood (local) 4ft X 8ft X 10mm Type: Type 1 (marine Plywood) 25 Pieces 3. Marine Type Plywood (local) 4ft X 8ft X 18 Mm Type: Type 1 (marine Plywood) 25 Pieces 1. Branded Premium Marine Type Plywood 4ft X 8ft Thickness: 5mm Type: Type 1 (marine Plywood) Approximately 8 – 9kgs Per Piece 10 Pieces 2. Branded Premium Marine Type Plywood 4ft X 8ft Thickness: 10mm Type: Type 1 (marine Plywood) Approximately 19– 20kgs Per Piece 10 Pieces 3. Branded Premium Marine Type Plywood 4ft X 8ft Thickness: 18mm Type: Type 1 (marine Plywood) Approximately 30 – 33kgs Per Piece 10 Pieces 1. Plasma Cutter Specifications: Current Input: 1ph 10 – 40a Torch Tpt40 (4 Meters) W/ Earth Clamp, 2 Meters Cable, 10mmˆ2 Inclusion For Tpt40 Plasma Torch: Alteast 4 Pieces Of Nozzles, 10 Pieces Of Tips, 2 Pieces Of Diffusers, 10 Pieces Of Electrodes 1 Unit 2. Mig/mag Welding Machine Specifications: 250a 240v 1hp Torch 250a (3 Meters) Earth Clamp (2.5 Meters) 190cr Co2 Flow Gauge Regulator Cga – 320 Inclusion Welding Mask And Gloves Feedroll Φ 0.8/1.0 Feedroll Φ 0.8/1.2 Contact Tip M6 1.0mm X 28mm (atleast 1 Piece) Carbon Teflon Liner I.d 1.5mm 3.5m – Black W/ 0.8 – 1.0mm (atleast 1piece) Carbon Teflon Liner I.d 1.5mm 3.5m – Black W/ 1.0 – 1.2mm (atleast 1piece) 1 Unit 1. 200 Liters Plastic Chemical / Water / Oil Barrel Specifications: Hdpe Plastic Vertical Water Drum Bucket Type: Double Ring Closed Top Color: Blue 18 Pieces 2. ½” Galvanized Iron Pipe (s-20) Diameter: ½”, 6m Length 45 Pieces 3. ¾” Galvanized Iron Pipe (s-20) Diameter: ¾”, 6m Length 28 Pieces 4. 1” Galvanized Iron Pipe (s-20) Diameter:1”, 6m Length 40 Pieces 5. 1 ¼” Galvanized Iron Pipe (s-20) Diameter: 1 ¼”, 6m Length 10 Pieces 6. 1 ¼” Galvanized Iron Pipe (s-40) Diameter: 1 ¼”, 6m Length 10 Pieces 7. 2” Galvanized Iron Pipe (s-40) Diameter: 2”, 6m Length 10 Pieces 8. 2 ½” Galvanized Iron Pipe (s-40) Diameter: 2 ½”, 6m Length 10 Pieces 9. 3” Galvanized Iron Pipe (s-40) Diameter: 3”, 6m Length 10 Pieces 10. 4” Galvanized Iron Pipe (s-40) Diameter: 4”, 6m Length 10 Pieces 11. 1” Mild Steel Flat Bar Thickness: 2mm; 6m Length 15 Pieces 12. 2” Mild Steel Flat Bar Thickness: 5mm; 6m Length 25 Pieces 13. 3” Mild Steel Flat Bar Thickness: 5mm; 6m Length 10 Pieces 14. Mild Steel Checkered Plate Dimensions: 4ft X 8ft; Thickness: 10m 5 Pieces 15. Mild Steel Plate Dimensions: 4ft X 8ft; Thickness: 10mm 2 Pieces 16. Grade 4 Deformed Steel Bar Diameter: 12mm; 6m Length 10 Pieces 1. Welding Protection Apron Material: Cowhide – Leather Type: Long Sleeve Apron Durable; Heat And Flame Resistant One Size Fits All 5 Pieces 2. Pvc Apron Material: Pvc Apron Pc – 2151 Color: Gray Chemical Resistant Suits 10 Pieces 3. Good Quality Leather Welding Gloves Ai – 140 Welding Gloves With Linings Size: 13 Inches Color: Orange 5 Pairs 4. Working Cover – All Suits (ppe) Color: Gray Durable, Waterproof Sizes: 3 Pieces Small (s) 3 Pieces Medium 2 Pieces Large 2 Pieces Extra Large 25 Pieces 5. White Cloth Sleeve Washable Clothe Sleeve Arm Protection 20 Pairs 6. White Safety Helmet (hard Hat) Material: Abs Inclusive Of Chin Strap Color: White 25 Pieces 7. Safety Life Vest Working Type Life Vest With Whistle And Reflector 15 Pieces 8. Welding Protection Mask Moisture Proof Welding Mask Polupropylene Shell 5 Pieces 9. Marine Life Buoy/ring About 2.5kg Life Ring Solas Approved Life Ring Outside Diameter: 725mm Inner Diameter: 445mm Buoyancy: ≥14.5kg Buoyancy Material: Urethane Foam Shell: High Density Polyethylene With Reflector 5 Pieces 10. Industrial Safety Boots Color: Black Ce Approved En20345 – S1p Steel Toe Cap Steel Midsole Anti – Static And Anti – Vibration And Oil Resistant And Slip Resistant Split Leather Upper Size: 2 Pairs For 7 Uk Size 2 Pairs For 8uk Size 2 Pairs For 9uk Size 2 Pairs For 10uk Size 2 Pairs For 12uk Size 10 Pairs 11. Led Flashlight With 4 Sets Of Extra Batteries 2 Cell Battery Explosion Roof Color: Orange And Black 2 Pieces 12. Branded High Quality Steel Tape Measure Length: 3 Meters 2 Pieces 13. Branded High Quality Steel Tape Measure 2 Pieces 14. Branded High Quality Steel Tape Measure Length: 8 Meters 2 Pieces
Province Of Davao De Oro Tender
Telecommunication Services
Philippines
Closing Date7 Jan 2025
Tender AmountPHP 468.6 K (USD 8 K)
Details: Description Republic Of The Philippines Province Of Davao De Oro Office Of The Governor Bids And Awards Committee Itb No. 24-092 Invitation To Bid For Supply And Delivery Of Access Switch With 10g Transceivers With Optical Transceiver Sfp 10g Single Mode 1. The Provincial Government Of Davao De Oro, Through The Ab Cy 2024/sb2 Capital Outlay Intends To Apply The Sum Of Four Hundred Sixty-eight Thousand Six Hundred Fifteen Pesos (php 468,615.00) Being The Abc To Payments Under The Contract For Supply And Delivery Of Access Switch With 10g Transceivers With Optical Transceiver Sfp 10g Single Mode For The Use Of Structured Cabling- Picto With Purchase Request No. 24-5664 Under Bid No. B-24-0326 Rebid. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The Provincial Government Of Davao De Oro Now Invites Bids For The Above Procurement Project. Delivery Of The Goods Is Required By Sixty (60) Days. Bidders Should Have Completed, Within Two (2) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. A. Bidding Is Open To All Interested Bidders, Whether Local Or Foreign, Subject To The Conditions For Eligibility Provided In The 2016 Revised Irr Of Ra No. 9184. 4. Prospective Bidders May Obtain Further Information From Bids And Awards Committee (bac) Secretariat Office, 3rd Floor, Right Wing, Provincial Capitol Building, Cabidianan, Nabunturan, Davao De Oro Province And Inspect The Bidding Documents At The Address Given Below During Mondays To Fridays (8:00 A.m. To 5:00 P.m.). 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On December 31, 2024 From The Given Address And Upon Payment Of The Applicable Fee For The Bidding Documents To The Provincial Government Of Davao De Oro, Thru Provincial Treasurer’s Office, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of Five Hundred Pesos (php 500.00). The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees In Person. It May Also Be Downloaded Free Of Charge From The Website Of The Philippine Government Electronic Procurement System (philgeps) And The Website Of The Procuring Entity, Provided That Bidders Shall Pay The Applicable Fee For The Bidding Documents Not Later Than The Submission Of Their Bids. 6. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Below On Or Before January 7, 2025 Until 8:30 A.m. Late Bids Shall Not Be Accepted. 7. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 8. Bid Opening Shall Be On January 7, 2025, 9:30 A.m. Onwards At 3rd Floor, Bids And Awards Conference Room, Provincial Capitol, Cabidianan, Nabunturan, Davao De Oro Province. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 9. The Provincial Government Of Davao De Oro Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 10. For Further Information, Please Refer To: Jenes B. Miñoza Head – Bac Secretariat Bids And Awards Committee (bac) Secretariat Office 3rd Floor, Right Wing, Provincial Capitol, Cabidianan, Nabunturan, Davao De Oro Province – 8800 Cel #: 0946-470-6261 Email Address: Bac@davaodeoro.gov.ph 11. You May Visit The Websites: For Downloading Of Bidding Documents: Philgeps.gov.ph / Davadeoro.gov.ph Date Of Issue: December 31, 2024 Sgd: Lara Zaphire Kristy N. Bermejo, Mpa Chairperson, Bids And Awards Committee
City Of Canlaon Tender
Civil And Construction...+2Civil Works Others, Construction Material
Philippines
Closing Date2 Jan 2025
Tender AmountPHP 424 K (USD 7.3 K)
Details: Description Republic Of The Philippines City Of Canlaon Office Of The Bids And Awards Committee Invitation To Bid For The Improvement Of Plaza The Local Government Of Canlaon City, Through The Aip 2023, Ord. No. 116, Series Of 2024 Intends To Apply The Sum Four Hundred Twenty-four Thousand, Twenty & 42/100 (p424,020.42) Being The Abc To Payments Under The Contract For The Supply And Delivery Of Various Construction Materials For Use In The Improvement Of Plaza, Purok Rose A, Brgy. Malaiba, Canlaon City. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. The Local Government Of Canlaon City, Now Invites Bids For The Supply And Delivery Of Various Construction Materials For Use In The Improvement Of Plaza, Purok Rose A, Brgy. Malaiba, Canlaon City. Delivery Of The Goods Is Required 7 Calendar Days After Issuance And Receipt Of Notice To Proceed. Bidders Should Have Completed, Within Ten Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Open To All Interested Bidders, Whether Local Or Foreign, Subject To The Conditions For Eligibility Provided In The 2016 Revised Irr Of Ra No. 9184 Interested Bidders May Obtain Information For The City Government Of Canlaon City Thru The Office Of The Bids And Awards Committee And Inspect Bidding Documents During Office Hours (8:00am To 5:00pm), Monday To Friday. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders Starting On December 11, 2024 To January 2, 2025 Until 10:00 Am At The Office Of The Bids And Awards Committee, Canlaon City, And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of Five Hundred (p500.00) Pesos. The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees By Facsimile. Bids Must Be Received By The Bac Secretariat Through Manual Submission On Or Before January 2, 2025, 10:00 Am At The Office Of The Bids And Awards Committee, 2nd Floor, City Hall Building, Canlaon City. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. Bid Opening Shall Be On January 2, 2025, 10:00 Am At The At The Office Of The Bids And Awards Committee 2nd Floor, City Hall Building, Canlaon City. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. For The Purpose Of Constituting A Quorum, Either The Physical And Virtual Presence Of The Bac Member Shall Be Considered Pursuant To Gppb Resolution No. 09-2020. The Local Government Unit Of Canlaon Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. For Further Information, Please Refer To: Alice D. Mcguiggan Bac Secretariat Mobile No. 0917-561-7931 Email Address: Bacofficelgucanlaon@yahoo.com Date Of Posting: December 10, 2024 Zosilito A. Ongco Bac Vice-chairman Republic Of The Philippines City Of Canlaon Bids And Awards Committee Control No.: #1 Bid Form Name Of Project: Improvement Of Plaza Brief Description: Supply And Delivery Of Various Construction Materials Location: Purok Rose A, Brgy. Malaiba, Canlaon City Bill Of Quantities Stock No. Quantity Unit Of Issue Item Description Unit Cost Unit Cost Total Cost 1. 3 Shts. ¼'' X 4' X 8' , Plywood, Marine 547.00 2. 10 Pcs. 1.0mm Thick 2"x4" Gi C-purlins 875.00 3. 2 Pcs. 10mm Thick X 150mm X 150mm Steel Plate 300.00 4. 1 Pc. 10mm X 100mm X 100mm Angular Bar 9,200.00 5. 12 Lngths 10mmɸ X 6m Deformed Bars 238.33 6. 8 Pcs. 12mm Thick X 100mm X 200mm Steel Plate 270.00 7. 12 Lngths 12mmɸ X 6m Deformed Bars 333.33 8. 2 Pcs. 14"φ Cutting Disc For Cut-off 578.00 9. 2 Pcs. 16mmɸ Def. Bar 591.00 10. 16 Pcs. 16mmφ X 400mm Long Anchor Bolts With Nuts And Washers, Ks 300.00 11. 4 Pcs. 20mm Thick X 300mm X 300mm Baseplate With 4-18mmφ Drill Hole Near At 4 Corner 3,500.00 12. 4 Pcs. 3"φ Gi Pipe Sch. 40 3,805.00 13. 120 Bd. Ft. 36 - 2'' X 2'' X 10 ' , Lumber, Rough 55.00 14. 1 Pc. 4"φ Grinding Stone 317.00 15. 12 Pcs. 4"φ Cutting Disc 200.00 16. 1 Gal. Aluminum Paint, Enamel 1,251.00 17. 41 Cu.m Crushed Gravel ¾'' 2,378.00 18. 1 Kg. Cw Nails, #1½ 100.50 19. 2 Kgs. Cw Nails, #3 91.50 20. 3 Kgs. Cw Nails, #4 126.00 21. 2 Gals. Latex Paint, Gloss White 1,067.00 22. 11 Kgs. E6013 Welding Rod 2.40mmφ Wipweld, Ordinary 176.00 23. 21 Cu.m Fine Sand 1,348.00 24. 2 Kg. Ga.16 Gi Tie Wire 103.00 25. 4 Pcs. Lamp Bracket For Steel Pole Mounting, 50 Mm ɸ X 1.6 M, 3 Mm Thick, Galvanized Coated 4,000.00 26. 1 Gal. Mayon Laquer Thinner 782.00 27. 4 Pcs. Paint Brush 2" 52.00 28. 375 Bags Portland Cement 310.00 29. 2 Ltrs. Red Lead Paint 300.00 30. 1 Gal. Reflectorized Traffic Paint, White 1,650.00 31. 1 Gal. Reflectorized Traffic Paint, Yellow 1,650.00 32. 4 Sets Solar Panel, 12v, 80 - 100 W, 665 Mm Length X 500 Mm Width X 13 Mm Thick Complete With Bracket Frame And Safety Clip, Mppt Charger With Driver & Dc Cable 5,000.00 33. 4 Sets Solar Street Lamp, 60w, 12 - 18 V Dc, Warm White, Smd 150 - 175 Lm / Watt, Complete W/ Lithium Ferro Phosphate (lifepo₄) Battery, 170 Wh Minimum, Mppt Charger W/ Driver, Pir Sensor ( Built-in ), Aluminum Die-cast And Polycarbonate Cover 15,000.00 Total Brand Model:_____________ Delivery Period:______________________ Warranty: After Having Carefully Read & Accepted Your General Conditions. I/we Quote On The Item/s Price/s Noted Above. Total Bid Price (in Words) Bid Security: Amount: Submitted By: Bidder/supplier Date:_________________________
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Healthcare and Medicine
United States
Closing Date10 Jan 2025
Tender AmountRefer Documents
Details: Sources Sought Notice sources Sought Notice *= Required Field
sources Sought Notice page 1 Of 4
page 1 Of 4 this Is A Sources Sought Notice Only. The Purpose Of This Sources Sought Notice Is To Obtain Information Regarding The Availability And Capability Of All Qualified Sources To Perform A Potential Requirement, And To Gain Knowledge Of Potential Qualified Service-disabled Veteran Owned Small Business (sdvosb), Veteran Owned Small Business (vosb), Small Business Manufacturers, And Other Small Businesses, Interested And Capable Of Providing Items Requested, As Well As Any Large Business Interested And Capable. This Request For Information/sources Sought Notice In Support Of The Portland Va Medical Centers, Is For Market Research Purposes And Planning Purposes Only And Is Not To Be Construed As A Commitment By The Government. The Government Will Not Pay For Information Solicited. Respondents Will Not Be Notified Of The Results Of The Evaluation. Results Will Be Used To Determine Set-aside. the Intended Contract Is A Firm-fixed Price Supply Purchase. the Sba Non-manufacturer Rule Is Applicable, And A Waiver Will Not Be Sought For This Potential Acquisition. potential Contractors Shall Provide, At A Minimum, The Following Information: 1) Company Name, Address, And Point Of Contact, Phone Number, E-mail Address, And Sam.gov Uei Number/code. 2) Anticipated North American Industry Classification System (naics) Code Is 339113. The Largest A Firm Can Be And Still Qualify As A Small Business For Federal Government Programs Is No More Than 800 Employees. Please Indicate Whether You Are A Small Business, Sdvosb, Vosb, Small Business Manufacturer, Other Small Business, Or Large Business, And Whether You Are The Manufacturer Of The Items Listed Below. 3) The Government Is Not Obligated To Nor Will It Pay For Or Reimburse Any Costs Associated With Responding To This Sources Sought Notice. This Notice Shall Not Be Construed As A Commitment By The Government To Issue A Solicitation Or Ultimately Award A Contract, Nor Does It Restrict The Government To A Particular Acquisition Approach. The Government Will In No Way Be Bound To This Information If Any Solicitation Is Issued. Notice To Potential Offerors: All Offerors Who Provide Goods Or Services To The United States Federal Government Must Be Registered In The System Award Management (sam Located On The Web At Www.sam.gov). It Is Desirable That Any Offeror To Have Completed Their Business Online Representations And Certifications Application In The System For Award Management (sam). 4) Any Service-disabled Veteran Owned Businesses Or Veteran Owned Businesses Who Respond To A Solicitation On This Project Must Be Registered With The Small Business Administration Vetcert Registry Located At Https://veterans.certify.sba.gov. 5) If Not A Manufacturer, Only Authorized Representatives/providers/distributors Of The Manufacturer Will Be Considered. Equipment Must Be New, No Used Or Refurbished Equipment Accepted. Please Provide A Proof Of Authorized Dealer Or Reseller Letter From Manufacturer. 6) If You Are The Manufacturer, Do You Have Any Designated Or Authorized Distributors? If So, Please Provide Their Name, Telephone, Point Of Contact And Size Status (if Available). 7) This Is A Brand Name Or Equal Requirement. As Such, The Salient Characteristics Reflect The Physical, Functional, Or Performance Characteristics That Equal Products Must Meet To Satisfy The Government S Needs. To Be Considered For Any Potential Solicitation, Offers Of Equal Products, Including Equal Products Of The Brand Name Manufacturer, Must: (a) Meet The Salient Physical, Functional, Or Performance Characteristic Of The Brand Name Item And Those Specified In This Sources Sought; Clearly Identify The Item By Brand Name, If Any And Make/model Number. (b) Include Descriptive Literature Such As Illustrations, Drawings, Or A Clear Reference To Descriptive Data Or Information Available That Identifies That The Equal Item Meets Or Exceeds The Salient Characteristics Required By The Government. (c) Identify The Manufacturer Name (oem) And Manufacturer Part Number, As Well As Any Warranty Information. (d) Please Provide A Courtesy Quote In Response To This Request To Evaluate Price Reasonableness For Any Set-aside Determination, And Any Applicable Contract Vehicle Information. it Is The Intent Of The Va To Use The Information Gathered For Market Research Purposes Only. If A Formal Solicitation Is Released, It Will Be Posted Via The Contracting Opportunities Website Located At Beta.sam.gov. Or Gsa Ebuy. description Of The Requirement: the Department Of Veterans Affairs Is Looking To Obtain Information On Vendors Who Can Provide The Products As Outlined Below. This Is An Unrestricted/open Market Brand Name Or Equal To Request For Information/sources Sought Notice. delivery: portland Va Medical Center
community Living Center
1601 E 4th Plain Blvd
vancouver, Wa 98661 items: Brand Name Or Equal To Hillrom Centrella item #
description/part Number*
qty Price Extended Amount 1
centrella Bed With Pro Surface
cnt 255
3 2
centrella Smart+ Bed With Max Air Surface And Blower
cnt 355
8 3
bed Base
cnt Base
11 4
nurse Call In Siderail
11 5
accessory Outlet
11 6
patient Helper Bracket
11 7
osi Patient Helper Sleeve
11 8
pro Surface For 36 Inch Frame
3 9
safeview With Illumiguide
3 10
second Lcd Touchscreen
3 â Subtotal (products)
â salient Characteristics max Air Feature Powered Air Mattress Operates Continuously To Decrease Localized Heat And Moisture Buildup. Allows For Continuous Full-body Pressure Redistribution For Patients 70 To 500 Pounds, Automatically Adjusts The Air System To Accommodate Changes Weight Distribution.
ability To Override And Increase Firmness For Patient Transfers Or Adjust Patient Position.
ability To Adjust For Patient Comfort, With 2 Zones, Which Can Be Adjusted Separately.
gci Touchscreen Located On The Outside Of The Head Rails For Quick Caregiver Access To Patient And Bed Status As Well As Other Bed Controls. Approximate Size 4x5 Inches
bed Exit Silence Exit Alarm Settings To Include Silence, Auto Reset, And Visual And Audible Safety Prompts. brake Not Set Alarm Spoken Verbal Safety Alert To Caution Caregiver And Patient In A Non-alarming Manner.
one Button Chair One Button Control To Convert A Flatbed Into A Cardiac Chair.
battery Backup - 12 Volt, 7 Mil Amp Hour Batteries X 2
digital Angle Indicator Digital Angle Indicator Gives The Specific Reading Of The Angle Of Bed If Trendelenburg Or Reverse Trendelenburg Positioning Is Needed. 18 Degrees Is The Maximum Achievable Angle.
built In Line And Cord Mgmt - Cutouts For Electrical Cord Or Monitor Cable Management For Use During Transporting. Located Within The Head And Footboards.
4 Iv Pole Sockets - Sized For Standard Hospital Iv Poles. 2-4 Bag Capacity.
integrated Restraint Holders - Sized For Standard Belt Restraints.
lockout Controls Ability To Lock Controls.
drainage Bag Holder Ability To Hold Up To 20 Pounds.
smart Bed Ready (sidecom Req) - Up To 32 Patients Safety And Bed Matrices To Be Transmitted To Caregiver Devices (such As Smart Phones, Vocera, Etc) And/or Vista Or Cerner Emr
wi-fi Module
enhanced 3-mode Bed Exit - Includes Silence, Auto Reset And Visual And Audible Safety Prompts.
motion Activated Nightlight
stand Assist - Height Adjust Buttons To Aid In Safely Lifting The Patient Onto Their Feet
advanced Slideguardâ® Feature - Reduces Patient Migration In Bed When The Head Of The Bed Is Raised
foley Position Limit - Monitors And Alerts If A Foley Bag Is Touching The Floor
patient Hob Angle Display - Digital Head Of Bed Angle Indicator Gives The Specific Reading Of The Angle Of The Head
trend/rev Trendelenburg Ranges From 0-18 Degrees.
dampened Emergency Cpr - Ability To Quickly And Safely Lower The Head Section To A Flat Position In Case Of A Code. Ability To Access From Both Sides Of The Bed.
patient Storage In Siderail - Sized To Hold Items Such As Smart Phone, Reading Glasses, Books/magazines. integrated Urinal Holders Ability To Hold Any Sized Urine Collection Bottle That Is Filled.
flexafoot Powered Bed Extend Powered Bed Length Extension.
steer Caster Font Left Caster Can Be Locked For Steering
36 Inch Frame Width
in-bed Scale Ability To Weight Up To 500 Pounds
usb Charger
2nd Lcd Touchscreen
patient Pendant - Moveable Bed Control That Allows The Patient Easy Access To Adjust The Bed S Head And Foot Sections. Approx. Size Is 3 X 5 .
removable Iv Pole
verbal Alerts Verbal Safety Alerts Such As Brake Not Set, Your Care Team Has Been Called, Please Don T Get Up, Etc. Able To Set 6 Different Languages.
additional Information Sought:
warranty Please Describe The Offered Warranty.
place Of Manufacture Please Provide The Place Of Manufacture. if Your Business Is Interested And Capable, Please Send The Capability Statement Outlined Above, And A Courtesy Market Research Quote To Maureen.sundstrom@va.gov By 3:00pm Pst On January 10, 2025. No Phone Calls, Please. again, This Is Not A Request For Quote, And No Solicitation Is Available At This Time.
GOVERNOR CELESTINO GALLARES MULTI SPECIALTY MEDICAL CENTER Tender
Healthcare and Medicine
Philippines
Closing Date3 Jan 2025
Tender AmountPHP 60.3 Million (USD 1 Million)
Details: Description Gov. Celestino Gallares Multi-specialty Medical Center Invitation To Bid For Supply, Delivery, Installation, Testing And Commissioning Of 2 Lots Various Medical Equipment Batch 3 (re-bid) For Gov. Celestino Gallares Multi-specialty Medical Center 1. The Gov. Celestino Gallares Multi-specialty Medical Center (gcgmsmc), Through The Health Facilities Enhancement Program 2024 Intends To Apply The Sum Of Sixty Million Three Hundred Forty-four Thousand Nine Hundred Seventy-five Pesos Only (php60,344,975.00) Being The Abc To Payments Under The Contract For Cb:2024-12-0007. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. The Gcgmsmc, Through The Health Facilities Enhancement Program 2024 Intends To Apply The Sum Of Sixty Million Three Hundred Forty-four Thousand Nine Hundred Seventy-five Pesos Only (php60,344,975.00) Being The Abc To Payments Under The Contract For Each Lot/item.et Al. Lot No. Item/description Quantity Unit Cost Total Cost 1 Infusion & Monitoring System 1 37,344,975.00 37,344,975.00 2 Advanced Perfusion System, Cardiopulmonary Bypass Pump + In-line Blood Gas Monitoring Device 1 23,000,000.00 23,000,000.00 Grand Total 60,344,975.00 Bids Received In Excess Of The Abc For Each Lot Shall Be Automatically Rejected At Bid Opening. 2. The Gcgmsmc, Now Invites Bids For The Above Procurement Project. Delivery And Installation Of The Goods Is Required Within 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Bidders Should Have Completed, Within 3 Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. A. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From Gcgmsmc Through Electronic Mail Via Procurement@cpspecialtycenter.org Or Through The Cellular Number 09209437250. 5. A Complete Set Of Bidding Documents May Be Acquired And Downloaded By Interested Bidders From Gcgmsmc Google Drive From (procurement@cpspecialtycenter.org) On December 08, 2024– January 03, 2025 And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Indicated Below In Accordance With The Following Schedule: Lot No. Item/description Total Cost Bidding Documents Fee (in Philippine Peso) 1 Infusion & Monitoring System 37,344,975.00 25,000.00 2 Advanced Perfusion System, Cardiopulmonary Bypass Pump + In-line Blood Gas Monitoring Device 23,000,000.00 25,000.00 The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees Through Online Banking Or Online Deposit With The Following Bank Details: Bank Name: Development Bank Of The Philippines Account Name: Gcg Multi-specialty Medical Complex Account Number: 00-0-15490-780-5 "for Bidders Choosing To Pay Via Online Transfer Or Bank Deposit, Please Ensure That Proof Of Your Successful Transaction Is Promptly Sent To The Procurement Email Address: Procurement@cpspecialtycenter.org. In Compliance With Coa Circular Number 2021-014, Clause 5.2, An Acknowledgement Receipt Will Be Issued As Proof Of Verified And Received Payment. Access To Bidding Documents Will Be Granted Only Upon Presentation Of This Acknowledgement Receipt. 6. The Gcgmsmc Will Hold A Pre-bid Conference On The 17th Day Of December 2024 At 0900h At Room 3c-e310 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur Cortes, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission On Or Before The 3rd Day Of January 2025 At 0900h At Gcgmsmc Procurement Office Room 3c-w327 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur, Cortes, Bohol. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On The 3rd Day Of January 2025 At 0900h At Room 3c-e310 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur Cortes. Bids Will Be Opened In The Presence Of The Bidders’ Authorized Representatives Together With Their Company Id. 10. The Gcgmsmc Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. Submission Of Hardcopies: Bidders Shall Submit Their Original Eligibility And Technical Documents Described In Itb Clause 10 In One Sealed Envelope Marked "original - Technical Component", And The Original Of Their Financial Component In Another Sealed Envelope Marked "original Financial Component", Sealing Them All In An Outer Envelope Marked "original Bid". Each Copy Of The First And Second Envelopes Shall Have 2 Copies And Similarly Sealed Duly Marking The Inner Envelopes As "copy No. 1 Technical Component" And "copy No. 1- Financial Component” And "copy No. 2- Technical Component" And "copy No. 2- Financial Component" And The Outer Envelope As "copy No. 1" And "copy No. 2" Respectively. These Envelopes Containing The Original And The Copies Shall Then Be Enclosed In One Single Envelope. Please Take Note That All Notarized Documents Must Be Treated As Original Copies For All The Submitted Documents (original, Copy 1, And Copy 2). It Is Imperative That Each Copy Retains Its Original Notarization To Ensure Legal Validity And Compliance. The Original And The Number Of Copies Of The Bid As Indicated In The Itb Clause 15 Shall Be Typed Or Written In Ink And Shall Be Signed By The Bidder Or Its Duly Authorized Representative/s. All Envelopes Shall: A. Contain The Name Of The Contract To Be Bid In Capital Letters; B. Bear The Name And Address Of The Bidder In Capital Letters; C. Be Addressed To The Procuring Entity's Bac In Accordance With Itb Clause 1; D. Bear The Specific Identification Of This Bidding Process Indicated In The Itb Clause 1 12. For Further Information, Please Refer To: Mary Grace L. Simbajon Jessa O. Quiñal Procurement Office Procurement Office Malayo Sur, Cortes, Bohol Malayo Sur, Cortes, Bohol Procurement@cpspecialtycenter.org Procurement@cpspecialtycenter.org +639209437250 +639452478632 December 06, 2024 Approved By: (signed) Doreen A. Lugo, Lpt Bac Chairperson Noted By: (signed) Laurence Elliot R. Tirol, Md, Fpcp Medical Center Chief ------------------------------------------------------------------------------------------------------------ Item: 1 Unit: Lot Qty: 1 Unit Cost: 37,344,975.00 Total Cost: 37,344,975.00 Description: Supply, Delivery, Installation, Testing & Commissioning Of Infusion & Monitoring System 150 Pump, Volumetric Infusion 40 Docking Station/s 1 Central Monitoring System 1 Mri-compatible Infusion System 1 Oximetry Monitoring System, Non-invasive Pump, Infusion Volumetric, 150 Units Size Less Than Or Equal To 210 (l) X 140 (w) X 73 (h) Millimeters (mm) Weight Less Than Or Equal To 1700 Grams (g) Screen Must Be At Least Three (3) Inches, Touchscreen, Thin Film Transistor (tft) Color Liquid Crystal Display (lcd), At Least 200 X 400 Pixel/s, Adjustable Brightness Levels Display Must Show The Following Information At Least: Infusion Status With Drug/s Name, Infusion Parameter/s, Real-time In-line Pressure; System Status Information With Infusion Mode, Intravenous Set Brand Or Bed Number, Alarm Symbol/s, Battery Status, Network Status, Relayed Status, And System Time; Must Show Infusion Status Indicator On The Door Accuracy: ≤ ± 4.5% Mode/s: Rate Mode, Dose Mode, Dose Time Mode, Time Mode, Sequential Mode, Intermittent Mode, Loading Dose Mode, Ramp Mode, Micro-infusion Mode And/or Drip Mode Must Support The Following Application/s : Intravenous Drug Infusion, Enteral Nutrition Feeding, And/or Blood Transfusion Flow Rate/s: 0.10-2300 Milliliter/s (ml) Per Hour (hr) And/or 0.10-2000 Ml/hr Increment/s: 0.01 Ml/hr (0.10-99.99 Ml/hr), 0.1 Ml/hr (100-999.9 Ml/hr), 1 Ml/hr (1000-2300 Ml/hr) Preset Time/s: 00:00:01-99:59:59 Preset Volume: 0.10-9999.99 Ml With Increments Of 0.01 Ml Accumulated Volume: 0.00-99999.99 Ml “keep Vein Open”: (kvo): 0.1-5.0 Ml/hr With Increment/s Of 0.01 Ml/hr Purge Rate: 0.1-2300 Ml/hr Bolus Rate: 0.1-2300 Ml/hr, Automatic Or Manual Occlusion Detection: 50-1125 Millimeters Mercury (mmhg) With At Least 15 Selectable Levels Such As 50, 150, 225, 300, 375, 450, 525, 600, 675, 750, 825, 900, 975, 1050, 1125 Mmhg); With Default Of 450 Mmhg; Pre Alarm Pops Up While Pressure Is Increasing; Auto-restart Capability Where On/off And Restart The Infusion When Occlusion Pressure Is Reduced; Pressure Unit/s Available Such As, Millimeters Mercury (mmhg), Kilo Pascal/s (kpa), Bar, And/or Pounds Per Square Inch (psi) Air Bubble Detection, With At Least Six (6) Level/s, 15, 50, 100, 250, 500, 800 Microliter/s; Air Accumulation 0.1-1.0 Ml Per 15 Minutes Dose Rate Unit/s Must Include The Following: Ng/kg/min, Ng/kg/hr, Ng/kg/24h; Ug/kg/min, Ug/kg/h, Ug/kg/24h, Mg/kg/min, Mg/kg/h, Mg/kg/24h; Mu/kg/min, Mu/kg/h, Mu/kg/24h; U/kg/min, U/kg/h,u/kg/24h; Ku/kg/min, Ku/kg/h, Ku/kg/24h; Eu/kg/min, Eu/kg/h, Eu/kg/24h; Mmol/kg/min,mmol/kg/h, Mmol/kg/24h; Mol/kg/min, Mol/kg/h, Mol/kg/24h; Mcal/kg/min, Mcal/kg/h, Mcal/kg/24h; Cal/kg/min, Cal/kg/h, Cal/kg/24h; Kcal/kg/min, Kcal/kg/h, Kcal/kg/24h; Meq/kg/min, Meq/kg/h, Meq/kg/24h; Auto Lock Time: 1-5 Minute/s Range With On/off Switch Drug Library Up To 5000 Drug/s, 30 Categories, Support For Color-coding History Log Up To 3500 Event/s Volume Collection Available In At Least 4 Method/s Including, 24 Hour Total, Current Total, Period, Timing Volume, Support History Rate Review Dose Error Reduction System Available Definition Of Dose Limit/s Automatic Alarm/s When Reaching Dose Limit/s Intravenous (iv) Administration Set Must Be Able To Accept Universal Iv Set/s Alarm/s Audible And Visual Alarm/s; Sound Volume Adjustable At Least Eight (8) Level/s 2 Level/s: High: Air In Line, Accumulated Air, Empty, Drop Error, Upstream Occlusion, Downstream Occlusion, Infusion Set Disengaged, No Infusion Tube, Infusion Set Error, No Drop Sensor, Battery Depleted, Volume To Be Infused (vtbi) Complete, Kvo Finish, Relay Invalid And/or System Error Low: Kvo Running, Battery In Use, Battery Error, Cms/egw Disconnected, Standby Time Expired, Dock Connection Interrupted, System Time Error, Relay Invalid Soon, Time Near End, Reminder And/or Low Battery Reminder: 1-5 Minute/s, On/off Switchable Connectivity Communication Wired And Wireless Usb Support Drug Library Import, Patient Data Import/export, History Record Export, Calibration Date Import/export; Multifunction Connector: Rs232, Nurse Call Connector, Dc Adapter Integration: Connect With Infusion Central Station, Connect With Central Monitoring System Battery Operating Time: More Than Or Equal To Five (5) Hour/s At 25 Ml/hr Charging Time: Less Than Or Equal To Five (5) Hour/s To Full Capacity Power Supply Voltage 100-240 Volt/s, Frequency 50-60 Hertz, (hz), Current 0.5-0.21 Ampere/s (a) Work Environment Level Of Resistance To Water And Dust At Least Ingress Protection Rating 33 (ip33) Classification Type Cf, Class 1, Ip33 Docking Station, 40 Units Size: Atleast270 (l) X 170 (w) X 390 (h) Millimeters (mm) Weight: Less Than Or Equal To 3900 Grams Display Screen At Least Three (3) Inches Organic Light Emitting Diode (oled) At Least 265 X 64 Pixels Resolution Showing The Following Information: Bed Number, Patient Name, Battery Status, Network Status, Total Volume For 24 Hours; Must Be Able To Connect Via Hl7 Protocol And Integrate With Hospital Information System/s And/or Electronic Medical Record/s Via Wired Or Wireless Protocol; Usb Support For Drug Library Importation, Patient Information Loading, Patient Data Export, History Record And/or Barcode Reader Connection Multifunctional Connector Rs232 And/or Nurse Call Connector Integration Capability To Synergise/connect With Patient Monitor, Connect With Infusion Central Station, And/or Connect With Central Monitoring System Night Mode Capability With On/off, Start Time, End Time And Sound Volume Adjustable History Record Up To 2500 Mounting Type For Horizontal And Vertical Pole Clamp: Horizontal Diameter Range 10 To 25 Mm; Vertical Diameter Range 15 To 40 Mm; One Pole Clamp Per Shelf Module Programmable Mode: Support Automatic Multi-channel Relay Maintenance: Support 2 To 24 Pumps Tool Free Assembly, Support Batch Calibration, Drug Library Import, And Software Upgrade/s Classification: Type Cf, Class 1, Ip33 Power Supply Battery: Lithium-ion 2500mah Operating Time Of At Least 2 Hours Charging Time At Most 6 Hours Ac Power: 100 To 240 V, 50 To 60 Hertz, 8 To 3.4 A Alarm/s Audible And Visual Alarm/s 2 Level/s: High: Battery Depleted, System Error : Low: Slave Controller Abnormal, Battery In Use, Low Battery, Battery Error, Local Area Network (lan) Internet Protocol (ip) Address Conflict, Wireless Lan Ip Address Conflict, Cms, Egw Disconnect Central Monitoring System System Component/s: Central Station System Center Which Connects Bedside Device/s Hardware: Display/s At Least 24 Inch Tft Lcd Screen/s Medical Grade, At Least Dicom 14, At Least Ip54 Rating Iec 60601, Touch Screen; Must Include Printer/s, Keyboard/s, Mouse/s And Speaker/s Main System Software Specification/s: Number Of Device Up To 64 Patient Monitor/s And Infusion Pump/s Per Station Alarm: Category: Physiological Alarm, Technical Alarm And System Prompt Remote Control: Alarm Switch, Alarm Limits, Alarm Priority, Alarm Pause And Alarm Reset Alarm Analysis: Support Alarm Statistics Trend Review: At Least 240 Hours; Full Disclosure At Least 240 Hours; Data Interface Connection Interface Integrated Egateway Or Standalone Egateway Mri Compatible Infusion System, 1 Unit Size Less Than Or Equal To 560 (l) X 540 (w) X 1540 (h) Mm Including Trolley, Excluding Iv Pole Weight Less Than Or Equal To 50 Kilograms Without Pump/s Display Screen At Least 3 Inches, Oled, 256 X 64 Pixels, Showing The Following Information: Bed Number, Patient Name, Battery Status, Network Status, Total Volume For The Past 24 Hours Infusion Of The Pump; Compatible Pumps At Least 4 Infusion Or Syringe Pumps Mri Scanner Compatibility For Both 1.5 And/or 3.0 Tesla Model/s Alarm/s Audible And Visual Alarm/s 2 Level/s: High: Battery Depleted, Magnet Indicator Battery Depleted, System Error : Low: Low Battery, Magnet Indicator, Battery Low, Battery Error, Lan Ip Address Conflict, Wlan Ip Address Conflict, Network Disconnected Magnet Indicator: Magnetic Field To Be Used In Magnetic Fields Up To 20 Mt; < 20 Mt Green; 20-40 Mt Yellow; > 40 Mt Red; Connectivity Communication Wired Or Wireless Usb Support Drug Library Import, Patient Data Import/export, History Record Export, System Upgrade Integration: Synergy With Patient Monitor, Connect With Infusion Central Station, Connect With Central Monitoring System Material: Ingress Protection Level Ip33 Safety Standards En 60601-1:2006 / A1:2013; En 60601-1-2:2015; En 60601-1-8:2007/a11:2017; F2025-15; F2182-19; F2213-17; F2503-20; Classification Type Cf Class Power Supply Battery: Lithium-ion At Least 3400mah; Ac Power: 100 To 240 V, 50 To 60 Hertz Dock: Operating Time At Least 10 Hours; Charging Time At Most 6 Hours Magnet Indicator: Operating Time Of At Least 720 Hours; Recharging Time At Most 8 Hours Oximetry Monitoring And Connectivity System, 1 Unit Expandable Patient Monitoring And Connectivity Hub That Integrates An Array Of Technologies, Devices, And Systems To Provide Multimodal Monitoring And Connectivity Solutions In A Single Clinician-centric Platform Regional Oximetry, Non-invasive Pulse Oximetry Display Resolution At Least 1280 X 800 Pixels, At Least 10 Inches Diagonal Size, Multi-touch Touchscreen; Customizable Multiple Screen Views To Feature The Most Applicable Data; Can Display Tissue Oxygen Saturation Of Specific Area; Can Display The Difference Between Current Rso2 And User Defined Baseline; Can Display The Difference Between Rso2 And Spo2; Pulse Rate; Perfusion Index; Pleat Variability Index; High-resolution Plethysmograph Waveform And/or Can Display Spectrogram Representing Activity For Both Sides Of The Brain; Must Have Ports Or Docks That Are Compatible To Plug And Play Modules For The Measurement Of Brain Function Monitoring, Regional Oximetry, And Non-invasive Pulse Oximetry Battery Capacity Is At Least Four Hours Module/s: Cerebral Oximetry At Least One, Pulse Co-oximetry At Least One Can Be Used As Bedside, Handheld And/or Transport Monitor Configurable Parameter And Alarm Settings By Patient Population Audible And Visual Alarms For Quick Identification Of Alarming Parameters With Redundant Speaker System. Particulars Vendor Shall Warrant That The Product Supplied Shall Equal The Published Specifications. Vendor Shall Provide No Less Than Five (5) Years Warranty On The System/equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair The System During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Vendor Must Conduct Quarterly Preventive Maintenance Program Or Frequently As Recommended By Principal / Manufacturer. Vendor Agrees To Add Equipment Down-time (in Number Of Days) To Total Warranty Period. Vendor Must Respond With Technical Support Staff, Either Remotely 2 Hours Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; And Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user; System/equipment Shall Be Delivered With At Least One (1) Copy Of All Service Manuals And At Least One (1) Copy Of All User Manuals. System/equipment Shall Be Delivered Complete With All Cabling, Connectors, Junction Boxes, Mounting Hardware, And All Other Accessories Necessary For Full Operation Of The System/equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid Any And All Software Necessary To Technically Support The System Shall Be Included Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied Devices Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted System For Not Less Than Five (5) Years After The Warranty Period Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or Engineer And/or End-user. Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimates For Major Spare Part/s Vendor To Shoulder Any Expenses Related To Delivery, Installation, Commissioning, Permit/s, Training And Other Sundries Necessary For The Complete Installation Of The Equipment Vendor Must Have Available Technical Staff And/or Office/s Within The Region Principal/manufacturer May Preferably Have An Existing / Active Quality Management System Certification E.g. Iso 13485 And/or Iso 9001 Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Principal’s / Manufacturer’s Products Must Have Been Present In The Local Market For The Past Ten (10) Years Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. -------------------------------------------------------------------------------------------------------------------- Item: 2 Unit: Lot Qty: 1 Unit Cost: 23,000,000.00 Total Cost: 23,000,000.00 Description: Advanced Perfusion System, Cardiopulmonary Bypass Pump + In-line Blood Gas Monitoring Device Heart & Lung Machine With Integrated Centrifugal Pump Built In Centrifugal Pump With The Following Specifications: Controls And Monitor Must Be Mounted To The Machine Drive Unit Must Allow For Interchangeable Components (must Have Flexible Drive Unit For Better Handling) Remote Control Display Panel Must Include The Centrifugal Status And Alarms Flow Sensor Must Be Non-invasive Type One (1) Integrated Centrifugal Pump Plus Either (a) Three (3) Singular Large Pumps + Two (2) Single Small Roller Pump Or (b) A Total Of Five (5) Roller Pumps With Flat Screen Monitor For Heart & Lung Machine Functionality Display Roller Pump Must Have Tubing Clamp Assembly Must Be A Rotatable Pump Head. With Hand Crank Intended For Manual Use In The Event Of Power Failure For Both Roller And Centrifugal Pump With Complete Safety Mechanism Device. Dual Pressure Module Sensor With Two (2) Cable Pressure Intended For Arterial Cardioplegia Digital Pressure Monitoring And Two (2) Manometer For Manual Monitoring. One (1) Temperature Module With At Least Two (2) Channels Level Sensor And Air Bubbles Sensor Intended For Adult And Pedia Circuits That Will Trigger The Machine To Temporarily Stop Avoiding Air Introduction To Patient With Mechanical Gas Blender For Oxygen And Compressed Air With Hose And Accessory Connectors Inclusion Of Vacuum Regulator Device Halogen Or Led Console Lamp With Flexible Arms Back-up Battery Which Can Provide Power For At Least 1 Hour Must Provide At Least Six (6) Pieces Of Tubing Clamp With Guard Can Be Powered By 230v ±10, 60hz With Four Heavy Duty Rolling Wheels And Non-scratching With Lock System Included In-line Blood Gas Monitoring Device The Machine Must Be Capable Of A Continuous Determination Of The Following Tests While On Cardiopulmonary Bypass (cpb): Blood Gas (ph, Pco2, Po2, Hco3, Be, So2) Electrolytes & Hematology (k+, Hgb, Hct) Patient Temperature Oxygen Deliver (do2) Inclusion Of Battery Pack To Ensure Uninterrupted Operation. Capable Of Displaying Alert/alarm Indicator When Parameters Fall Outside The Normal Values Must Be Lcd Or Led Screen Machine Must Be Portable And Fit With The Provided Pole Clamps/bracket For Monitoring In The Heart Lung Machine Cable Head Sensor For Testing Must Be Capable For Arterial Or Venous Sampling Monitoring Must Include Printer For Documentation Of Displayed Values 60 Hertz Machine Electrical Requirement Heater Cooler Machine, At Least Two (2) Unit/s Must Have At Least Two (2) Independent Circuits Intended Either For: A. Oxygenator Heat Exchangers And B. Patient Blankets One (1) Pair Of Hose With Corresponding Connectors For Each Independent Circuit Per Unit Can Be Powered By 230v ±10, 60hz Particulars Vendor Shall Warrant That The Product Supplied Shall Equal The Published Specifications. Vendor Shall Provide No Less Than Five (5) Years Warranty On The System/equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair The System During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Vendor Must Conduct Quarterly Preventive Maintenance Program Or Frequently As Recommended By Principal / Manufacturer. Vendor Agrees To Add Equipment Down-time (in Number Of Days) To Total Warranty Period. Must Provide Back-up Immediately Upon Notification Where Applicable. Vendor Must Respond With Technical Support Staff, Either Remotely (2 Hours) Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; And Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user; System/equipment Shall Be Delivered With At Least One (1) Copy Of All Service Manuals And At Least One (1) Copy Of All User Manuals. System/equipment Shall Be Delivered Complete With All Cabling, Connectors, Junction Boxes, Mounting Hardware, And All Other Accessories Necessary For Full Operation Of The System/equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products And Model/s Nearing And/or At The End-of-cycle Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid; Any And All Software Necessary To Technically Support The System Shall Be Included Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied Devices Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted System For Not Less Than Five (5) Years After The Warranty Period Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or Engineer And Other Technical Staff (end-user/s); Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimates For Major Spare Part/s Vendor To Shoulder Any Expenses Related To Delivery, Installation, Commissioning, Permit/s, Training And Other Sundries Necessary For The Complete Installation Of The Equipment Vendor Must Have Available Technical Staff And/or Office/s Within The Region Principal’s/ Manufacturer Products May Preferably Have An Existing/active Quality Management System Certification E.g. Iso 13485 And/or Iso 9001 Principal’s / Manufacturer’s Products Must Have Been Present In The Local Market For The Past Ten (10) Years, May Provide Certification Where Applicable Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances.
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Electrical Generators And Transformers...+1Electrical and Electronics
United States
Closing Date3 Jan 2025
Tender AmountRefer Documents
Details: This Sources Sought/market Survey Notice Is Being Conducted By Aleda E. Lutz Va Medical Center, 1500 Weiss Street, Saginaw Mi, 48602 To Identify All Sources That Are Capable Of Providing Maintenance Service For Emergency Generator For The Period Of April 5, 2025 April 4, 2026 At The Discretion Of The Government In Strict Accordance With All Schedules, Specifications, Terms, Conditions And Provisions Of This Contract.
general Information
visit #1 Furnish All Tools, Labor, Materials, Parts, And Laboratory Services To Perform The Following Specified Maintenance On The Five Generators Listed At The End Of This Document:
all Maintenance, Service, Operational Checks, And Parts Shall Be Performed And Supplied Per The Manufacturer S Recommendations By Manufacturer Certified Technicians.
contractor Shall Provide All Fluid Analysis Reports And Within 7 10 Days After Completion Of Maintenance. contractor Performance Shall Be Monitored Through Service Reports That Shall Be Submitted After Each Repair Has Been Conducted.â Field Service Reports Must Be Submitted Within 7-10 Days And Will Be Reviewed For Accuracy And Timely Submission.
contractor Shall Perform Services Within 60 Days Of Award.
maintenance Checks: radiator Core For Air Flow
antifreeze Protection
coolant Level
coolant Inhibitor Strength (add Conditioner If Required To Update Strength)
radiator Cap And Seal
coolant Leaks
lube Oil Level
fan Belt Tension
condition Of All Hoses
hose Clamps
condition Of Flex Fuel Lines
day Tank Float Controls, Solenoid, And Main Fuel Pump Operation
fuel System For Leaks
cranking Voltage Drop
battery Electrolyte Level
battery Voltage
battery Charger Rate
battery Cables And Connections
flex Exhaust Couplings Rain Flashing
turbo Wheel For Bearing Wear
terminal Strip Connections
loose Relays In Control Panel
jacket Water Heater Operation
governor Oil Level
governor Linkage
remote Governor Control Operation
air Gap On Generator
collector Rings And Brushes
oil And Dirt Buildup In Generator
system For Loose Bolts, Etc.
crank Termination Time
engine Instruments
abnormal Noise Or Vibration
exhaust Characteristics Louver Operation
crankcase Blow By
voltage And Frequency
all Switches In Correct Position
drain Water And Sediment From Day Tank
lubricate Generator Bearing
clean Engine Crankcase Breather
lubricate Fan Pulley
clean Primary Filter
drain Exhaust Moisture Traps
inspect The Turbocharger For End Play And Leaks maintenance Services:
note: All Filters Shall Be Oem
change Air Cleaner Elements, Check Seals, Air Cleaner Indicators And Air Induction System
take Oil Sample And Perform Infrared Analysis (performed By A Fluid Analysis Lab)
take Fuel And Coolant Samples And Perform Analysis (performed By A Fluid Analysis Lab)
change Lube Oil And Filters, Lube Oil Is To Be Replaced With Fully-synthetic Oil In Accordance With Manufacturers Recommendations change Fuel Filters
oil, Fuel, And Coolant Samples Taken Will Be Delivered To The Testing Laboratory In A Reasonable Time As To Not Compromise The Samples. Care Will Be Taken As To Storing The Samples As Recommended By The Testing Laboratory Until They Are Delivered.
operational Checks:
recheck Oil Level While Running
recheck All Fluid Systems For Leaks
used Oil Transportation And Recycling: transportation And Recycling Of Used Oil Shall Be Performed In Accordance With Federal, State And Local Regulations Including: michigan Natural Resources And Environmental Protection Act 451, Of 1994 As Amended, Part 121 Liquid Industrial By-product. prior To Transporting Used Oil From The Property, The Transporter Must Provide A Shipping Document Describing The Materials In Accordance With Above Regulation For Certification By The Detroit Vamc Gems Program Manager Or Designee. The Contractor Shall Arrange For The Designated Recycling Facility To Notify The Cor, In Writing, That The Shipment(s) Arrived At Its Destination Within 7 Days Of The Date The Shipment Left The Facility. michigan Hazardous Material Transportation Act 138. prior To Transporting Used Oil From The Property, The Contractor Shall Provide A Copy Of The Act 138 Transporter S Permit And Registration To The Cor For The Approval Of The Gems Program Manager. During Transport, The Transporter Must Also Be Able To Produce A Copy Of The Act 138 Permit And Registration, Either Via Electronic Record Or Hard Copy, To Deq Staff Or A Peace Officer When Requested. generator #1
cummins/onan Model: Dfeb-4955010 Sn: B010204440 kw: 400 Pf: .8 Volt: 120/208 Amp: 1387 generator #2 mtu Onsite Energy Model: 400pxc6dt3 Sn: 331914-1-1-0411 kw: 400 Pf: .8 Volt: 120/208 Amp: 1387 generator #3 cummins/onan Model: 350 Dfcc Sn: G920477586 kw: 350 Pf: .8 Volt: 277/480 Amp: 526 generator #6 mtu Onsite Energy Mod: 750rxc6dt2(g05) Sn: Wa-572596-0410 kw: 750 Pf: .8 Volt: 277/480 Amp: 1127 generator #7 mtu Onsite Energy Mod: Ds00500d6srah1583 Sn: 331787-1-1-0411 kw: 500 Pf: .8 Volt: 277/480 Amp: 751 If This Is A Service Your Business Can Provide, Respond To This Sources Sought By Friday, January 3, 2025; 3:00 P.m. Eastern Time. Responses Should Include: (1) Business Name And Address (2) Point Of Contact Name, Phone Number, And E-mail Address (3) Sam Uei And Naics Code (4) Business Size Small Or Large (5) Type Of Business Service Disabled Veteran Owned, Veteran Owned, 8a, Hubzone, Women-owned Etc. (6) Applicable Gsa/fss Contract Number (if Applies). All Businesses Eligible To Provide This Service Are Encouraged To Reply As This Information May Be Used To Determine Potential Set-asides For The Above Noted Service. E-mail Responses To: Ariel Bautista-lagares, At Ariel.bautista-lagares@va.gov (note: This Is Not A Request For Quote Or An Announcement Of A Solicitation.)
MUNICIPALITY OF DOLNI LANOV Tender
Others
Czech Republic
Closing Date7 Jan 2025
Tender AmountCZK 6.7 Million (USD 275.4 K)
Details: The subject of the public contract is construction work and related supplies and services consisting in the reconstruction of the existing bridge structure, which transfers local traffic over the bed of a watercourse with a permanent flow (malé Elbe – Vodní Linie Idvt: 10100231). The existing bridge shows a number of faults that need to be resolved as soon as possible. A separate diagnostic construction and technical survey was prepared for the bridge structure, including recommendations for further management of the bridge structure. For this reason, the contracting authority decided to carry out the reconstruction of the existing bridge structure within the given scope, while retaining the existing horizontal supporting structure. The necessary modification of the local traffic on both bridgeheads is also being addressed as part of the reconstruction. The reconstruction requires the lateral relocation of the cable line.
2541-2550 of 2569 archived Tenders