Tenders of Animal And Plant Health Inspection Service Usa
Tenders of Animal And Plant Health Inspection Service Usa
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
Chemical Products
United States
Usda-aphis-ppq Requires A Set Of Product Chemistry Registration Studies To Be Completed On A Pesticide End Use Product Called “spinosad Fruit Fly Bait” Which Contains 1.8% W/w Spinosad In Accordance With Federal Insecticide, Fungicide, And Rodenticide Act (fifra) Good Laboratory Practices (glps) [1]. These Product Chemistry Studies Must Follow The Epa Study Guidelines Oppts 830.6317 (storage Stability), 830.6320 (corrosion Characteristics), 830.6302 (color), 830.6304 (odor), 830.6303 (physical State), 830.7300 (bulk Density), 830.6313 (stability To Normal And Elevated Temperatures, Metals, And Metal Ions) [2].
the Government Will Provide The Contract Laboratory The Spinosad Technical Reference Standard And An Appropriate Analytical Chemistry Method To Be Used In The Applicable Study Guidelines Listed Above (830.6317/6313). As Part Of This Contract, The Contract Laboratory Will Produce A Glp-compliant Certificates Of Analysis (coa) For The Spinosad Technical Reference Standard And Validate The Provided Analytical Chemistry Method In Accordance With The Glps Prior To Completing The Studies Listed Above.
the Resulting Final Reports For The Product Chemistry Registration Studies Listed Above Must Also Meet The Fifra Glp Requirements And Epa's Data Submission Format Requirements (epa Prn 2011-3: Standard Format For Data Submitted Under Fifra And Certain Provisions Of Ffdca [3]) To Support A Future Pesticide Registration Application To The Environmental Protection Agency (epa).
Closing Date15 Nov 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
United States
This Is A Source’s Sought Notice As A Means Of Conducting Market Research. The Usda Aphis Vs Is Seeking All Interested Sources Capable Of Providing A Olympus Bx53 Microscope & Dp75 Camera Or Equal Product. The Usda Aphis Is Considering The Use Of A Purchase Order To Obtain This Supply. The Result Of This Market Research Will Contribute To Determining The Method Of Procurement. The Applicable North American Industry Classification System (naics) Code Assigned To This Procurement Is 334516 Analytical Laboratory Instrument Manufacturing. The Size Standard For This Code Is 1000 Employees For Determination Of Small Business Status. Product Service Code Is 6640. The Specifications For The Product Are As Follows;
purpose:
this Requirement Is For The United States Department Of Agriculture, Animal And Plant Health Inspection Service, Veterinary Services To Replace Aging Equipment.
technical Requirements:
evident Scientific (manufacturer) Olympus Bx53 Microscope And Dp75 Camera Or Equal Microscope And Camera
microscope:
observation Method: Brightfield, Darkfield, Phase Contrast, Fluorescence (blue/green
excitations), Differential Interference Contrast,
polarized Light, Simple Polarized Light
ability For Future Upgrade To Fluorescence (ultraviolet Excitations)
illuminator: Transmitted Köhler Illuminator- Led Lamp
focus: Focusing Mechanism-stage Focus
intermediate Magnification Changer: Manual Terret
revolving Nosepiece: Manual- Coded (7 Positions), Standard (7 Positions)
stage: Mechanical- Oil Rectangular Stage With Right-hand Control (x: 76 Mm (3 In.), Y: 52 Mm (2 In.)), Plain Stage - Dimensions: 180 Mm × 150 Mm (7 In. × 6 In.)
condenser: Manual-universal Condenser (na 0.9/ W.d. 1.5 Mm For 1.25x–100x [swing-out: 1.25x–4x, With Oil Top Lens: (na 1.4/ W.d. 0.63 Mm)]), Swing-out Condenser (na 0.9/ W.d. 2 Mm (1.25x–100x)), Achromatic/aplanatic Condenser (na 1.4/ W.d. 0.7 Mm (oil) (10x–100x)), Darkfield Condenser Dry (na 0.8–0.92/ W.d. 4.52 Mm (10x–40x)), Darkfield Condenser Oil (na 1.2–1.4/ W.d. 0.5 Mm (20x–100x), Low Magnification Condenser (na 0.75/ W.d. 1.55 Mm (2x–100x)), Abbe Condenser (na 1.1/ W.d. 0.7 Mm (oil) (4x–100x)), Phase Contrast Condenser (na 1.1/ W.d. 0.7 Mm (4x–100x)) Polarizing Condenser (na 0.9/ W.d. 1.3 Mm (slide Glass 1.5 Mm) (4x–100x))
observation Tubes:
widefield (fn 22) - Binocular, Tilting Binocular, Trinocular, Tilting Trinocular, Ergonomic Tilting Binocular, Tilting, Telescopic, Lifting, Binocular, Trinocular For Infrared, Erected Trinocular, Erected Ergonomic Tilting Binocular.
super Widefield (fn 26.5) - Trinocular, Erect Image Tilting Trinocular
dimensions (w × D × H): 274.5 Mm × 614 Mm × 469 Mm (10.8 In. × 24.2 In. × 18.5 In.) (epifluorescence Configuration)
weight: 21 Kg (46.3 Lb) (epifluorescence Configuration)
operating Environment:
indoor Use- Ambient Temperature (5°c–40 °c (41 °f–104 °f))
maximum Relative Humidity - 80% For Temperatures Up To 31 ºc (88 ºf), Decreasing Linearly Through 70% At 34 ºc (93 ºf), 60% At 37 ºc (99 ºf), To 50% Relative Humidity At 40 ºc (104 ºf)
supply Voltage Fluctuations - ±10 %
camera:
camera Type: Single-chip Color Camera (pixel Shifting)
cooling System: Peltier Device (active Cooling)
image Sensor: 1.1 Inch 12.37 Megapixel Color Cmos Image Sensor, Global Shutter
resolution (max.): 8192 (w) × 6000 (h) Pixels
pixel Size: 3.45 X 3.45 µm
effective Image Resolution: 8192 X 6000 (pixel Shifting), 4096 X 3000 (3cmos Mode), 4096 X 3000 (1x1), 3840 X 2160 (1x1) (by Cropped), 2048 X 1500 (2x2), 2048 X 1500 (1x1), 1920 X 1080 (1x1), Roi
sensitivity: 1x/2x/4x/8x/16x/32x (iso 100 / 200 / 400 / 800 / 1600 / 3200 Equivalent)
a/d Converter: 12 Bits
binning: 2 × 2
metering Modes: Mode: Auto / Sfl-auto/ Manual, Adjustment: ±2.0 Ev Step: 1/3 Ev, Time: 28 μs - 120 S
white Balance: Auto / One-touch / Manual / Area Designation
black Balance: Auto / One-touch / Manual / Area Designation
exposure Times: 28 μs–120 S
live Frame Rates: Max. 22 Fps At 4096 × 3000 (full Resolution), Max. 22 Fps At 2048 × 1500 (2 × 2), Max. 44 Fps At 2048 × 1500 (1 × 1), Max. 60 Fps At 1920 × 1080 (1 × 1, Full Hd)
still Image Transfer Time: 8192 X 6000 (pixel Shifting):approx. 3 S, 4096 X 3000 (3cmos Mode) :approx. 2 S, 4096 X 3000 (1x1):approx. 1.2 S, 2048 X 1500 (2x2) :approx. 1.0 S, 2048 X 1500 (1x1) :approx. 0.4 S, 1920 X 1080 (1x1) :approx. 0.4 S
monochrome Mode: Available (standard / Custom )
color Space: Srgb, Adobergb
linear Mode: Available
ir-cut Filter: Switchable - In: 400 Nm - Up To 650 Nm Out: 400 Nm - Up To 1000 Nm
manual Panoramic Imaging (instant Mia): Available (supporting Fluorescence As Well As Brightfield )
auto Scene Recognition Mode: Available By Ai Algorithm (supporting Scene: Brightfield, Fluorescence, Phase Contrast, Differential Interference Contrast, And Polarization)
position Navigator: Available
control Software: Cellsens Entry / Standard / Dimension Ver 4.2.1 Or Later, Dp2-twain Ver 10.5 Or Later
cooling System: Peltier Cooling
external Trigger: Available (input / Output)
data Transfer: Usb 3.1 Gen2 (type-a)
partial Readout: Yes
computer Interface Requirements:
able To Connect In Pc Running Windows 10/11 Via Usb 3.1 Gen 2 Type A Connection.
must Be Able To Interface With Cellsens Imaging Software.
technical Support:
the Company Must Be Able To Provide Onsite Set Up And Technical Support For The Microscope And Camera Post Purchase.
------------------------------------------------------------------------------------------------------------------------
there Is No Solicitation Currently. This Is Only A Source’s Sought Notice For Market Research Purposes; Responses Will Be Used To Determine Whether This Requirement May Be Set-aside For Small Business Or Procured Through Full And Open Competition. Please Note That Preference Will Be Given To Domestic Sources In Any Future Solicitations. This Request For Capability Information Does Not Constitute A Request For Quote; Submission Of Any Information In Response To This Market Survey Is Purely Voluntary; The Government Assumes No Financial Responsibility For Any Costs Incurred.
if You Are An Interested Vendor, Please Provide The Following Information:
1) Business Name And Contact Information
2) Business Size And Confirmation Of Registration In Sam.gov By Providing Your Sam Uei Code
3) Capability Statements Addressing The Particulars Of This Effort, With Appropriate Documentation Supporting Claims Of Meeting Specifications Of The Microscope And Camera.
4) Product Country Of Origin.
electronic Responses Are Required. Telephone Inquiries Will Not Be Accepted Or Acknowledged, And No Feedback Or Evaluations Will Be Provided To Companies Regarding Their Submissions.
interested Parties Who Provide This Product In Accordance With The Specifications Provided Are Invited To Submit A Response To This Sources Sought Notice No Later Than Thursday, July 25th, 2024 At 3pm Ct. All Responses Under This Sources Sought Notice Must Be Emailed To Samantha Johnson At Samantha.johnson3@usda.gov.
Closing Date25 Jul 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
Aerospace and Defence
Corrigendum : Closing Date Modified
United States
Th-57 Transportation, Modifications, Inspections, And Return To Service Repairs
Closing Date15 Jul 2024
Tender AmountUSD 7.5 Million
This is an estimated amount, exact amount may vary.
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
United States
Tsx Universal Series Ultra-low Freezers
Closing Date29 Jul 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
Civil And Construction...+1Civil Works Others
United States
Montana - Ghmc Aerial Insecticide Application
Closing Date1 Aug 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
Corrigendum : Closing Date Modified
United States
Feral Swine Trappings Systems - Remote Gate & Camera System
Closing Date1 Aug 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
United States
The Nvsl Asf/csf Response Program Stockpiles Pcr Reagents For Asf And Csf Diagnostic And Surveillance Testing. This Stockpile Requires Specific Reagents That Have Been Approved By The Foreign Animal Disease Diagnostic Laboratory (faddl) For Diagnosis Of The Diseases In Swine. The Above Reagents Are Part Of The Approved Reagents Required For The Testing And Acts As Part Of The 100k Reaction Stockpile. The Stockpile Services All Other Laboratories Which Have Been Approved For Asfv/csfv Surveillance Testing Including The Dominican Republic Laboratory, The Puerto Rico Laboratory And The Wildlife Services Laboratory In Fort Collins.
• Only The Above Reagents Are Approved For Diagnostic Testing
Closing Date9 Aug 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
United States
Notice Of Intent To Award A Bpa Call Order Against Slf Chemical Bpas
Closing Date9 Aug 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
United States
Notice Of Intent To Award A Bpa Call Order Against Enterprise Telecommunications Solutions Bpa
Closing Date20 Aug 2024
Tender AmountRefer Documents
ANIMAL AND PLANT HEALTH INSPECTION SERVICE USA Tender
71-80 of 365 archived Tenders