Fire Alarm Tenders

Fire Alarm Tenders

Indian Army Tender

Goods
Civil And Construction...+1Construction Material
GEM
Tawang, Arunachal Pradesh
Description: CATEGORY: , Supply and fixing switch flame proof rotary type with termination box in LM 6 to 16 Amp , Supply and fixing Socket Plug and rotatory switch flame proof rotary type with termination box in LM 6 to16 Amp , Supply and fixing LED light fitting 2x20 Watt flame proof , Supply and fixing LED Flood light fitting 150 Watt flame proof , M and L for flame proof Aviation obstruction light Beacon with flasher complete all as directed. , M and L for flame proof Intrinsically safe Electronic Hooter of voltage 230 Volts AC complete all as directed. , Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick buried directly in ground , Supply and fixing Wiring for circuit or submain wiring in Steel Conduit , Supply and fixing flame proof MCB DB SPN 230V 6 Way Horizontal double door , Supply and fixing flame proof Metal Socket 3ph and Neutral Link 63 Amp complete with rotatory plug and Switch all as directed. , Supply and fixing flame proof MCB DB TPN 230V 12 Way Horizontal double door , Supply and fix single pointed air termination Copper rod 12 mm dia 300 mm long complete all as directed. , Supply and fix copper strip 32 mm x 6 mm burried in ground complete all as directed. , Test point terminal block made of gun metal or phosphorous bronge of size 75 x75 x 25 mm , M and L for Flame proof Wall Mounted Fan industrial type of size 36 inch 230 Volts , M and L for Flame proof Exhaust Fan industrial type of size 450MM 230 Volts , M and L for Chemical Earthing complete with Copper plate of size 90cmx60cmx5.0mm thick electrode , Supply and installation of Liquld Cool silent Diesel Engine driven generating set 415 volts 3 phase 4 wire of capacity 125 KVA , Cement OPC 43 Grade packed in HDPE bag each 50 Kg wt , Coarse sand free from vegetation , Coarse Aggregate 20mm graded , Coarse Aggregate 40mm graded , Hardcore 63 to 90mm , AAC Blocks 600x200x150 , Mild Steel Bars of size 10mm dia , Three phase 1.2 HP Monoblock pump 430 Volt complete as per ATC , Individual standalone plastic body smoke alarm with adequate provision , Individual standalone plastic body heat alarm , Fire extinguisher of Min 20 Kg wt Dry powder type , PVC Water sintex tank 5000 Ltr Cap three layers complete all as specified and as directed. , PPR Pipe 50mm dia complete all as specified and as directed. , Stone Dust , Coarse aggregate 40 mm graded , Stone boulder 8 inch used in 300mm soling , Bituminous Joint filling compound grade B , Bituminous joint filler baord 20mm thick , Polythene film 150 micron thickness , Recron , Thermoplastic Road marking paint , Water based acrylic paint , Wooden planks for shuttering 2nd class wood of size 3.0 x 0.30 x 0.026m , Road Delineator , Design Consultancy QR incl IIT Vetting , Labour Charge
Closing Date9 Oct 2024
Tender AmountRefer Documents 

Indian Army Tender

Goods
Furnitures and Fixtures
GEM
Corrigendum : Corrigendum Added
Tawang, Arunachal Pradesh
Description: CATEGORY: Superstructure of Relocatable Medium Living Shelter of size 10.66 M x 6.12 M x 4.40 M height with 1.50 M enclosed verandah in front side , Distribution box 8 way SPN , MCB SPN 240 Volts 32 Amps , MCB SP 6 to 32 Amps , PVC tape 19mm wide 5 m long , Copper cable of size 1.5 Sqmm single core , Copper cable of size 2.5 Sqmm single core , Copper cable multi stranded of size 4 Sqmm single core , PVC casing capping of size 1 inch , PVC casing capping of size 3by 4 inch , Switch Piano 5 Amp , LED Tube light fittings 15W 230V box type 4 feets , Screw full thread 6 x 19 mm ISI Marked with 200 Nos in Pkt , PVC switch board snow white 7 inch by 4 inch , PVC switch board snow white 8 inch by 10 inch , PVC L bend and T junction joint for PVC casing and capping , Switch socket combination snow white 15 Amp 230 Volts , Switch socket combination 5 amp , Service bracket 40mm dia GI Tubing medium grade 1.5 Mtr Long , Service cable PVC insulated aluminium conductor 10 Sqmm 2 Core , Ceiling Rose three terminal , LED Bulk head fitting with LED lamp 10 watts , PVC Flexible wire copper conductor multi stranded 0.0016 by 76 , PVC Conduit pipe 15 mm dia , PVC Round or Squire Block , Exhaust Fan 230 Volts 200 mm sweep alongwith louvers , Fire extinguisher of one kilogram capacity dry power , Earthing plate 600 x 600 x 6 mm , CI earth pit cover of size 300 x 300 x 6 mm , Funnel fitted with 20 mm diameter GI Pipe 1.5 m Long , GI wire 4 mm diameter , Charcoal , Salt normal , Air termination single pointed aluminium rod 12 mm dia and 300 mm long. , Testing point terminal block , Aluminium strips 25 x 3.0 mm , Galvanized Iron strip 32 x 6 mm , Funnel fitted with 20 mm diameter GI Pipe 1.5 m Long. , Insulating PVC block 75x75x30 mm with insulating clamp nut and bolt , Individual standalone plastic body smoke alarm , Individual standalone plastic body heat alarm , Fire ball extinguisher of 1.3 Kg wt , Double sleeping Bunk alongwith Ply wood and Matress , Steel Bed side Locker of size 1000mm X 1520mm X 450mm , Study chair of size length 56 Cm and Height 82 Cm and Width 56 Cm , Study Table of size 4 feet X 2 feet , Looking Mirror of selected quality frameless of size 600X450x5mm , Water Dispenser of 230 V 500 Watts , Protable indoor type High quality Kero Heater metal body , Peg set of six fitted with galvanised screws , Curtain Arrangement Drapery and rod made of 25 mm dia and 1600 mm long
Closing Date5 Jan 2024
Tender Amount₹ 21.5 Lac 
This is an estimated amount, exact amount may vary.

Indian Army Tender

Goods
Civil And Construction...+1Construction Material
GEM
Corrigendum : Corrigendum Added
Tawang, Arunachal Pradesh
Description: CATEGORY: Superstructure of Relocatable Medium Living Shelter of size 10.66 M x 6.12 M x 4.40 M height with 1.50 M enclosed verandah in front side , Distribution box 8 way SPN , MCB SPN 240 Volts 32 Amps , MCB SP 6 to 32 Amps , PVC tape 19mm wide 5 m long , Copper cable of size 1.5 Sqmm single core , Copper cable of size 2.5 Sqmm single core , Copper cable multi stranded of size 4 Sqmm single core , PVC casing capping of size 1 inch , PVC casing capping of size 3by 4 inch , Switch Piano 5 Amp , LED Tube light fittings 15W 230V box type 4 feets , Screw full thread 6 x 19 mm ISI Marked with 200 Nos in Pkt , PVC switch board snow white 7 inch by 4 inch , PVC switch board snow white 8 inch by 10 inch , PVC L bend and T junction joint for PVC casing and capping , Switch socket combination snow white 15 Amp 230 Volts , Switch socket combination 5 amp , Service bracket 40mm dia GI Tubing medium grade 1.5 Mtr Long , Service cable PVC insulated aluminium conductor 10 Sqmm 2 Core , Ceiling Rose three terminal , LED Bulk head fitting with LED lamp 10 watts , PVC Flexible wire copper conductor multi stranded 0.0016 by 76 , PVC Conduit pipe 15 mm dia , PVC Round or Squire Block , Exhaust Fan 230 Volts 200 mm sweep alongwith louvers , Fire extinguisher of one kilogram capacity dry power , Earthing plate 600 x 600 x 6 mm , CI earth pit cover of size 300 x 300 x 6 mm , Funnel fitted with 20 mm diameter GI Pipe 1.5 m Long , GI wire 4 mm diameter , Charcoal , Salt normal , Air termination single pointed aluminium rod 12 mm dia and 300 mm long. , Testing point terminal block , Aluminium strips 25 x 3.0 mm , Galvanized Iron strip 32 x 6 mm , Funnel fitted with 20 mm diameter GI Pipe 1.5 m Long. , Insulating PVC block 75x75x30 mm with insulating clamp nut and bolt , Individual standalone plastic body smoke alarm , Individual standalone plastic body heat alarm , Fire ball extinguisher of 1.3 Kg wt , Double sleeping Bunk alongwith Ply wood and Matress , Steel Bed side Locker of size 1000mm X 1520mm X 450mm , Study chair of size length 56 Cm and Height 82 Cm and Width 56 Cm , Study Table of size 4 feet X 2 feet , Looking Mirror of selected quality frameless of size 600X450x5mm , Water Dispenser of 230 V 500 Watts , Protable indoor type High quality Kero Heater metal body , Peg set of six fitted with galvanised screws , Curtain Arrangement Drapery and rod made of 25 mm dia and 1600 mm long
Closing Date14 Aug 2024
Tender Amount₹ 16 Lac 

Department Of Biotechnology Tender

Goods
Electrical Cables And Wires...+1Electrical and Electronics
GEM
Corrigendum : Corrigendum Added
K.V.Rangareddy, Telangana
Description: CATEGORY: Site prepartion , Soil excavation , Ordinary soil excavation , Hard rock , Excavation of foundation , Filling available earth , Supply and filling of earth , Disposal , Pcc , Shuttering , Steel reinforcement , Random rubble masonry , Concrete M20 , Concrete M25 , CC pavement , Brick work , Plastering , Putty , Primer , Painting , Exterior paint , Polyurethane floor coating , Epoxy flooring , Internal wall , Wall tiles , Tiles , Paver blocks , Aluminium doors 1 , Aluminium doors 2 , Aluminium windows , CPVC pipe 20mm , CPVC pipe 25mm , CPVC pipe 32mm , CPVC pipe 50mm , CPVC concealed , Water storage tank , RO plant , Water closet , Urinal , Wash basin , Khurras , PVC pipes , RCC pipes 1 , RCC pipes 2 , Manhole construction , SS pipe , Modular puff panel 60mm , Modular puff panel 100mm , Modular puff panel 80mm , Coving , Glazed panel glass , Single leaf door 1 , Single leaf door 2 , Double leaf door , Airtight door , MS staircase , Ms shed , Rolling shutter , Electrical main panel , Earth pit , VTPN DB 100 amps , VTPN DB 63 amps , Armored cable , Cable 1 , Cable 2 , Cable 3 , Cable 4 , Cable 5 , Cable 6 , Cable 7 , Cable 8 , Cable 9 , Cable 10 , Cable 11 , Cat 6 cable , Cable trays , LedLights 42w , LedLights 18w , Lights 40w , Tube lights 40w , Cable , Switch 6A , Switch 2point , Switch and socket 16A , Switch and socket 32A , Industrial Socket , 4 modular plates , 3 modular plates , 2 modular plates , Industrial plug , RJ45 plates , RJ 11 plates , Network rack , Junction box , Safety Thermostarts , Tier 300mm , Tier 150mm , Tier 100mm , Tier 50mm , UPS , Exhaust fans , Industrial exhaust fans , Conduit pipes 20mm , Conduit pipes 25mm , Conduit pipes 32mm , Geyser , AHU , Once thru , MS round ducting , GI rectangular ducting with rtv , GI rectangular ducting without rtv , Thermal insulation , Hooded hepa filters , SS circlips , Flexible connections , Return air terminal box 610mmx610mm , Return air terminal box 305mmx305mm , Grills , GSS powder coated swirl diffuser , SS swirl diffusers 1700 cmh , SS swirl diffusers 1100 cmh , SS swirl diffusers 500 cmh , Volume control dampers for risers , Motorised pressure relief dampers , Damper with modulating actuator , Motorised fire dampers , VAV in supply for bsl 2 areas , VAV in exhaust for bsl 2 areas , Airtight dampers , Multi leaf dampers , Exhaust fan system , Magnehelic gauges , Split Ac unit , Propeller fan , Bibo unit ss 304 , Waste bin , Table and chair , Storage racks , SS table , Sterile garment cubicle , Cross over bench with shoe rack , Disinfectant stand , SS polished mirror , Garment bin , SS water tank , Lab bench , Open storage racks , Pass box , Chair cover , Sink , Dynamic pass box , Horizontal Double door autoclave , Provision for CO2 line , Poultry Isolators , Workstation , Bio safety cabinet , Door interlock and access control system , Access Control with face detection Iris based , CC cameras , PA System , Fire smoke detection alarm , BMS , Communication facility intercom and lan , Fire extinguishers CO2 type , Fire extinguishers ABC dry powder type , Testing and certification , Addition of items if any , Warranty
Closing DateCancelled
Tender Amount₹ 4.7 Cr 

Department Of Biotechnology Tender

Goods
Civil And Construction
GEM
K.V.Rangareddy, Telangana
Description: CATEGORY: Site prepartion , Soil excavation , Ordinary soil excavation , Hard rock , Excavation of foundation , Filling available earth , Supply and filling of earth , Disposal , Pcc , Shuttering , Steel reinforcement , Random rubble masonry , Concrete M25 below plinth , Concrete M25 , CC pavement , Brick work , Plastering , Putty , Primer , Painting , Exterior paint , Polyurethane floor coating , Epoxy flooring , Internal wall , Wall tiles , Tiles , Paver blocks , Vitrified tiles , Aluminium doors 1 , Aluminium doors 2 , Aluminium windows , CPVC pipe 20mm , CPVC pipe 25mm , CPVC pipe 32mm , CPVC pipe 50mm , CPVC concealed , Water storage tank , RO plant , Water closet , Urinal , Wash basin , Khurras , PVC pipes , RCC pipes 1 , RCC pipes 2 , Manhole construction , SS pipe , Modular puff panel 50mm , Modular puff panel 100mm , Modular puff panel 50mm ceiling , Coving , Glazed panel glass , Single leaf door 1 , Single leaf door 2 , Double leaf door , Airtight door , MS staircase , Ms shed , Rolling shutter , Electrical main panel , Earth pit , VTPN DB 100 amps , VTPN DB 63 amps , Armored cable , Cable 1 , Cable 2 , MCCB , Cable 3 , Cable 4 , Cable 5 , Cable 6 , Cable 7 , Cable 8 , Cable 9 , Cable 10 , Cable 11 , Cat 6 cable , Cable trays , LedLights 42w , LedLights 18w , Lights 40w , Tube lights 40w , Cable , Switch 6A , Switch 2point , Switch and socket 16A , Switch and socket 32A , Industrial Socket , 4 modular plates , 3 modular plates , 2 modular plates , Industrial plug , RJ45 plates , RJ 11 plates , Network rack , Junction box , Safety Thermostarts , Tier 300mm , Tier 150mm , Tier 100mm , Tier 50mm , UPS , Exhaust fans , Industrial exhaust fans , Conduit pipes 20mm , Conduit pipes 25mm , Conduit pipes 32mm , Geyser , AHU , DX Direct Expansion , Once thru , MS round ducting , GI rectangular ducting with rtv , GI rectangular ducting without rtv , Thermal insulation , Hooded hepa filters , SS circlips , Flexible connections , Return air terminal box 610mmx610mm , Return air terminal box 305mmx305mm , Grills , GSS powder coated swirl diffuser , SS swirl diffusers 1700 cmh , SS swirl diffusers 1100 cmh , SS swirl diffusers 500 cmh , Volume control dampers for risers , Motorised pressure relief dampers , Damper with modulating actuator , Motorised fire dampers , VAV in supply for bsl 2 areas , VAV in exhaust for bsl 2 areas , Airtight dampers , Multi leaf dampers , Exhaust fan system , Magnehelic gauges , Split Ac unit , Propeller fan , Bibo unit ss 304 , Waste bin , Table and chair , Storage racks , SS table , Sterile garment cubicle , Cross over bench with shoe rack , Disinfectant stand , SS polished mirror , Garment bin , SS water tank , Lab bench , Open storage racks , Pass box , Chair cover , Sink , Dynamic pass box , Horizontal Double door autoclave , Provision for CO2 line , Poultry Isolators , Workstation , Bio safety cabinet , Air curtain , Door interlock and access control system , Access Control with face detection Iris based , CC cameras , PA System , Fire smoke detection alarm , BMS , Communication facility intercom and lan , Fire extinguishers CO2 type , Fire extinguishers ABC dry powder type , Testing and certification , Addition of items if any , Warranty
Closing Date16 Oct 2024
Tender Amount₹ 4.8 Cr 

Indian Army Tender

Goods
Electrical Cables And Wires...+2Electrical Goods and Equipments, Electrical and Electronics
GEM
Corrigendum : Corrigendum Added
Tawang, Arunachal Pradesh
Description: CATEGORY: Distribution box 6 way SPN 240 volts copper bus bar , MCB SPN 240 Volts 32 Amps , MCB SP 6 to 32 Amps , PVC tape 19mm wide 5 m long , Cable PVC insulated elecric cables 1.5 Sqmm single core , Cable PVC insulated elecric cables4.0 Sqmm single core , Cable PVC insulated elecric cables 2.5 Sqmm single core , PVC casing capping of size 1 inch , PVC casing capping of size 3 by 4 inch , Switch Piano 5 Amp 230 Volts Flush type one way , LED Tube light fittings 15 w box type 4 feets , Screw full thread 6 x 19 mm ISI Marked , PVC switch board snow white size 7 inch x 4 inch , PVC switch board 8 inch x 10 inch , PVC L and T bend , Switch socket combination multipurpose 2 in 1 15 Amp , Switch socket combination 5 Amp , Service bracket 40mm dia GI Tubing medium grade 1.5 Mtr Long , Service cable 10 Sqmm 2 core , Ceiling Rose three terminal , Distribution box 8 Way double door , PVC Flexible wire copper conductor multi stranded , PVC Flexible Conduit pipe 15 mm dia , PVC Round or Squire Block , Exhaust fan 230 volts 300 mm sweep plastic body alongwith louvers , Fire extinguisher of one kilogram capacity dry power type , Earthing plate 600 x 600 x 6 mm , CI earth pit cover of size 300 x 300 x 6 mm , Funnel fitted with 20 mm diameter GI Pipe 1.5 m Long. , GI wire 4 mm diameter , Charcoal , Salt normal , Conventional Air Teminal , Testing point terminal block make of Gun metal , Copper strip 0f size 20x.015mm 20x3.15mm , Galvanised iron strip 32x6mm , Tubes medum grade galvanised pipe of size 40mm bore , Earthing Plate 600x600x6mm GI steel , CI earth pit cover of size 300x300x6mm , Insulating PVC block 75x75x30mm , Individual standalone plastic body smoke alarm , Individual standalone plastic body heat alarm , Fire ball extinguisher of 1.3 Kg wt , Cement OPC 53 Grade in poly bags of 50 Kg , Sand coarse confroming to IS 383 , Stone aggregate coarse 20mm confroming to IS 383 , Stone aggregate coarse 40mm comforming to IS 383 , Stone aggregate coarse 40- 63mm comforming to IS 383 , TMT bar FE 550 grade 10mm dia , Water proofing compund conforming to IS 2645 2003 , GI binding wire , Wooden planks for shuttering IInd class wood of size 3.0 x 0.30 x 0.026m , PCC solid block of size 400x200x200 , Cement based paint Snowcem , Oil bound Distemper , APP based polymeric membrane , Priming surface and applying bitumen , Wooden Scantling Various Sizes , Steel props of size 2 mtr lon 80mm dia , Nails all sizes , Door size 2100x1200m double leaf all as specified in ATC , Loop Holes 1000 x 300 mm , Prefab jally made up of ISA 30x30x3mm and 24x25x3mm of size 900x900
Closing Date22 Jun 2024
Tender AmountRefer Documents 

Airports Authority Of India - AAI Tender

Goods
Electrical Goods and Equipments...+1Electrical and Electronics
GEM
Bhavnagar, Gujarat
Description: CATEGORY: Supply of 3.5 x 120 Sq.mm. aluminium conductor cable , Supplying of 120mm Dia HDPE pipe , Pulling of HDPE pipe direct in ground by Horizontal Directional Drilling method , Laying of cable in the existing pipes , Laying of cable direct in ground including , Laying of cable in masonry open duct , Laying and fixing of cable on wall surface , Supplying and making end termination , Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials , Supplying and fixing cable route marker , Providing, laying and fixing of 80 mm dia G.I. pipe , Wiring for light point or fan point or exhaust fan point or call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable , Wiring for circuit or submain wiring along with 2 x 1.5 Sq.mm plus 1 x 1.5 Sq.mm Earth Wire , Wiring for circuit or submain wiring along with 2 x 2.5 Sq.mm plus 1 x 2.5 Sq.mm Earth Wire , Supply and laying of size 2 x 1.5 sq. mm. copper conductor cable , Wiring for light or power plug with 2 x 4 Sq.mm FRLS PVC insulated copper conductor single core cable , Wiring for light or power plug with 4 x 4 Sq.mm FRLS PVC insulated copper conductor single core cable , Supplying and fixing of 25 mm PVC conduit along with accessories , Supplying and fixing suitable size GI box with modular plate and cover , Supplying and fixing modular blanking plate , Supplying and fixing two module stepped type electronic fan regulator , Supplying and fixing of 8 way, Double door horizontal type MCB DB , Supplying and fixing of 63 Amp rating Isolator , Supplying and fixing of 63 Amp rating RCCB , Supplying and fixing of 5 A to 32 A rating C curve MCB , Supply of 20Watt indoor surface and wall mounted LED batten , Installation, Testing and Commissioning of pre-wired, fluorescent fitting , Supply of 1 x 45-watt LED street light , Fixing of LED street light fitting on pole or wall , Supply of 1200mm sweep ceiling fan , Installation, Testing and Commissioning of ceiling fan , Supply of 300 mm sweep, 1400 RPM heavy duty exhaust fan , Installation of exhaust fan , Extra for fixing the louvers or shutters , Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick , Supplying and laying 25 mm x 5 mm GI strip at 0.50 meter below ground , Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia G.I. pipe , Providing and fixing 25 mm x 5 mm GI strip on surface or in recess , SITC of TPN automatic change over switch , Supply of fully Automatic Emergency Light , Supply and Installation of MOV based 40KA Surge Protection module , SITC of 02-zone fire detection and alarm panel , SITC of Autodialer , Supply and Fixing of conventional type photo electric smoke detectors , SITC of Hooter , SITC of Manual Call Point , SITC of 4.5 kg CO2 portable fire extinguisher , Supply and fixing of medium voltage synthetic insulating mat made of synthetic Elastomer , Installation, testing and commissioning of 1.5 or 2 TR split type ACs units including fitting of indoor and outdoor unit , Supply and fixing of Outdoor Unit Stand , Supply and fixing of suitable size Copper Refrigerant piping , Supply and fixing of 25mm dia PVC drain pipe , Supply and fixing of 4C x 2.5 or 4 Sq.mm size flexible copper wire , SITC of smart controller or Timer for automatic changing operation , Supply and fixing of 4 KVA rating wall mounting type automatic electronic voltage stabilizer , Dismantling of existing 1.5 TR or 2.0 TR Capacity, Single Phase Split type Air Conditioner units , Constructing brick masonry manhole
Closing Date15 Jan 2024
Tender Amount₹ 59.5 Lac 

Airports Authority Of India - AAI Tender

Goods
GEM
Corrigendum : Corrigendum Added
Varanasi, Uttar Pradesh
Description: BOQ ITEMS: Sub-Head A (Operation and Maintenance) Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Terminal Building, ATC Tower, Fire station including AC Operation, Pump Operation, Fire Fighting and alarm systems operation, GLF operation and other ancillary buildings including operation, repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following minimum manpower as per requirement in general shift per day. (a) Skilled Manpower(Electrician/Technician)-02 Nos. (Reliever Shall be Provided on Weekly Off/Holiday) (b) Unskilled Manpower(Helper -02 Nos. (Reliever Shall be Provided on Weekly Off / Holiday). Note-Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Sub-Station i/c repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance including operation of DG sets of different capacity and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following manpower as per requirement for round the clock operation in three shifts per day. (a) Skilled (Electrician/Technician)-03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday) (c) Unskilled(Helper) - 03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday) Note- Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Sub-Head B (Misc RandM works) Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.. 2.0 TR, 1 Phase, 230 V, 50 Hz Split AC Unit (1st Year), Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.. 2.0 TR, 1Phase, 230 V, 50 Hz Split AC Unit (2nd Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required. (Maintenance to be done through OEM/Authorized dealer/specialized agency.) Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)-(1st Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required. (Maintenance to be done through OEM/Authorized dealer/specialized agency.) Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3 Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)- (2nd Year), Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item) 1st Year , Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item) 2nd Year, Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required. 1st Year , Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required. 2nd Year, Annual comprehensive maintenance for RO System( Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item. 1st Year , Annual comprehensive maintenance for RO System (Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item. 2nd Year, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Shield Membrane, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Carbon/Sediment Filter, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. 2.5AMP 24VDC SMPS, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. KENT FRT 550, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent Choke, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent UF 4inch, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Shield Membrane, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Carbon/Sediment Filter, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. 2.5AMP 24VDC SMPS, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. KENT FRT 550, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent Choke, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent UF 4inch, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer) Ceiling Fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer) Wall Fan / Pedestal fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer) Exhaust Fan, Lifting and lowering of borewell submersible pump of various capacities (up to 3 HP) due to defect in existing pump on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing and commissioning complete as required., Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer) 1HP, Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer) 3HP, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. CO2 Type- 4.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. CO2 Type- 6.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. ABC Type 4KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. ABC Type 6KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. ABC Type 5KG Capacity, Dismantling of high wall split type air conditioning unit , re-installation, testing and commissioning of capacity up to 2 TR. air-conditioner units , fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required., Servicing of Land T Make, Model- CN-CS 800S1 Air circuit breaker 800 Amp through authorised service dealer of OEM/ specialized agency including carrying out of following works racking out and removal of ACB from switch board, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of ACB. Cleaning all parts with cleaning agents such as CRC 2-26 checking the various settings within the ACB of contacts, releases etc, checking the hardware for wear and tear, checking of termination and tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (Supply of spares / accessories required for healthiness of ACB are in AAI scope), regreasing of the ACB parts as recommended by OEM, refixing the ACB, testing and observance for normal operation of ACB complete as required. , Servicing/maintenance of existing 11 KV VCB panel (installed in HT panel room- Panel Type- AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019 ) as per recommendation of OEM / Authorized dealer of OEM/ specialized agency. , Testing for healthiness and carrying out calibration of all relays i/c secondary injection test installed in 11KV HT panel of sub-station and submission of test report and calibration certificate as required. Details of HT panel Panel is - AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019. Note- Testing and callibrations to be done by OEMs recommended callibrated Kit, by their Er./Technician or by Er./Technician of Authorized dealer of OEM/ specialised agency., Topping up transformer oil including oil filtration/ dehydration and oil sample testing of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Oil sample Testing of Transformer oil for 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019 etc. complete as required., Oil filtration and Dehydration i/c oil sample testing before and after of dehydration of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/09- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/10- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/09- (2nd Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/10- (2nd Year), Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter. (All the components required for servicing of RCD will be supplied by AAl ) 1st Year, Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter. (All the components required for servicing of RCD will be supplied by AAl ) 2nd Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required. 1st Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required. 2nd Year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates.(For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) . 1st year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates. (For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) . 2nd year
Closing DateCancelled
Tender Amount₹ 95 Lac 

Airports Authority Of India - AAI Tender

Goods
GEM
Varanasi, Uttar Pradesh
Description: BOQ ITEMS: Sub-Head A (Operation and Maintenance) Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Terminal Building, ATC Tower, Fire station including AC Operation, Pump Operation, Fire Fighting and alarm systems operation, GLF operation and other ancillary buildings including operation, repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following minimum manpower as per requirement in general shift per day. (a) Skilled Manpower(Electrician/Technician)-02 Nos. (Reliever Shall be Provided on Weekly Off/Holiday) (b) Unskilled Manpower(Helper -02 Nos. (Reliever Shall be Provided on Weekly Off / Holiday). Note-Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Sub-Station i/c repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance including operation of DG sets of different capacity and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following manpower as per requirement for round the clock operation in three shifts per day. (a) Skilled (Electrician/Technician)-03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday) (c) Unskilled(Helper) - 03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday) Note- Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Sub-Head B (Misc RandM works) Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.. 2.0 TR, 1 Phase, 230 V, 50 Hz Split AC Unit (1st Year), Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.. 2.0 TR, 1Phase, 230 V, 50 Hz Split AC Unit (2nd Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required. (Maintenance to be done through OEM/Authorized dealer/specialized agency.) Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)-(1st Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required. (Maintenance to be done through OEM/Authorized dealer/specialized agency.) Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3 Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)- (2nd Year), Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item) 1st Year , Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item) 2nd Year, Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required. 1st Year , Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required. 2nd Year, Annual comprehensive maintenance for RO System( Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item. 1st Year , Annual comprehensive maintenance for RO System (Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item. 2nd Year, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Shield Membrane, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Carbon/Sediment Filter, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. 2.5AMP 24VDC SMPS, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. KENT FRT 550, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent Choke, 1st Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent UF 4inch, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Shield Membrane, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Carbon/Sediment Filter, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. 2.5AMP 24VDC SMPS, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. KENT FRT 550, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent Choke, 2nd Year Replacement of following filter/ spare for above RO system etc. complete as and when required. Kent UF 4inch, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer) Ceiling Fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer) Wall Fan / Pedestal fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer) Exhaust Fan, Lifting and lowering of borewell submersible pump of various capacities (up to 3 HP) due to defect in existing pump on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing and commissioning complete as required., Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer) 1HP, Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer) 3HP, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. CO2 Type- 4.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. CO2 Type- 6.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. ABC Type 4KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. ABC Type 6KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required. ABC Type 5KG Capacity, Dismantling of high wall split type air conditioning unit , re-installation, testing and commissioning of capacity up to 2 TR. air-conditioner units , fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required., Servicing of Land T Make, Model- CN-CS 800S1 Air circuit breaker 800 Amp through authorised service dealer of OEM/ specialized agency including carrying out of following works racking out and removal of ACB from switch board, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of ACB. Cleaning all parts with cleaning agents such as CRC 2-26 checking the various settings within the ACB of contacts, releases etc, checking the hardware for wear and tear, checking of termination and tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (Supply of spares / accessories required for healthiness of ACB are in AAI scope), regreasing of the ACB parts as recommended by OEM, refixing the ACB, testing and observance for normal operation of ACB complete as required. , Servicing/maintenance of existing 11 KV VCB panel (installed in HT panel room- Panel Type- AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019 ) as per recommendation of OEM / Authorized dealer of OEM/ specialized agency. , Testing for healthiness and carrying out calibration of all relays i/c secondary injection test installed in 11KV HT panel of sub-station and submission of test report and calibration certificate as required. Details of HT panel Panel is - AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019. Note- Testing and callibrations to be done by OEMs recommended callibrated Kit, by their Er./Technician or by Er./Technician of Authorized dealer of OEM/ specialised agency., Topping up transformer oil including oil filtration/ dehydration and oil sample testing of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Oil sample Testing of Transformer oil for 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019 etc. complete as required., Oil filtration and Dehydration i/c oil sample testing before and after of dehydration of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/09- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/10- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/09- (2nd Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCR Sr. No. NS/MPCCR/09/2019/10- (2nd Year), Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter. (All the components required for servicing of RCD will be supplied by AAl ) 1st Year, Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter. (All the components required for servicing of RCD will be supplied by AAl ) 2nd Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required. 1st Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required. 2nd Year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates.(For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) . 1st year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates. (For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) . 2nd year
Closing Date16 Jul 2024
Tender Amount₹ 95 Lac 
3461-3470 of 3469 archived Tenders