Tenders of Public Buildings Service Usa
Tenders of Public Buildings Service Usa
Sorry!
No Active
Tenders of Public Buildings Service Usa
foundCheck archived
Tenders of Public Buildings Service Usa
PUBLIC BUILDINGS SERVICE USA Tender
United States
Closing Date7 Jul 2020
Tender AmountRefer Documents
This Procurement Is Set Aside To Small Business Concerns Only solicitation: 47pf0020r0055 notice 7/7/2020: We Have Received Notice That Contractors Are Encountering Difficulties Submitting Their Bids Due To Email Size Restrictions. In This Case, Contractors Should Email The Proposal In Separate Portions. Each Email Subject And Attachment Should Follow The Following Format: "firm Name, Metcalfe Childcare Renovation Proposal, Email ___ Of ____" update 6/26/20. Amendment 07 Hereby Extends The Proposal Due Date To Tuesday, 07/07/20 At 11:00 Am Cst. description the General Services Administration (gsa), Great Lakes Region (region 5), Will Be Issuing A Solicitation For General Construction Services At The Ralph H. Metcalfe Federal Building Located At 77 W. Jackson St. Chicago, Illinois 60604. the Purpose Of This Project Is To Renovate And Expand The Current Childcare Center. The Scope Is To Renovate The Existing 2000 Sf Center Of The First Floor, And Construct An Additional 6000 Sf On The Second Floor. This Will Involve The Demolition Of Existing Space To The Shell; Building 3 New Classrooms; Renovating Staff Offices; Replacing And Install New Ceilings; Install New Lighting And Controls; Install New Finishes; Install Films On Existing Glazing; Install New Window Treatments; Install A New Hvac System; Install New Restrooms; And Install A New Security System. The Expected Dollar Range For This Procurement Is $1,000,000 To $3,000,000. The Performance Period Is 443 Calendar Days Upon Receipt Of On-site Notice To Proceed. the Contractor Is To Provide All Management, Supervision, Manpower, Equipment And Supplies Necessary For This Project. The Proposed Contract Is Being Solicited As A Small Business Set Aside. The North American Industry Classification System (naics) Code For This Procurement Is 236220 (commercial And Institutional Building Construction). the Solicitation Cited Above Can Only Be Obtained By Accessing The Secure Website, Beta Sam (beta.sam.gov). Beta Sam Is Designed To Safeguard Controlled Unclassified Information (cui) Acquisition Information And Is Fully Integrated With Other Electronic Government Initiatives. Registration In Beta Sam Is Required In Order To Download Solicitation Documents And Is Used To Validate Vendor Identity. Contractors Not Registering In This System Will Be Ineligible To Download The Solicitation And Ineligible For An Award.
PUBLIC BUILDINGS SERVICE USA Tender
United States
Closing DateNA
Tender AmountRefer Documents
Justificaiton For Other Than Full And Open Competition (ofoc) In Accordance With Federal Acquisition Regulation 13.106-1(b). See Signed Attachment Of Ofoc.
PUBLIC BUILDINGS SERVICE USA Tender
United States
Closing Date4 Aug 2020
Tender AmountRefer Documents
Nch Chiller Replacement
amendment 02 the Purpose Of This Amendment Is To Provide A Ppi Log With A Complete Q&as As Of 7/29/2020, And A Site Visit Attendee List.
the Rfp Due Remain As Tuesday, August 4, 2020 At 1:00pm Pdt. amendment 01 a. The Purpose Of This Amendment Is To 1) Provide A Ppi Log With A Complete Q&as As Of 7/27/2020 With Two Electrical Drawings, Ep-601-vwa00358.pdf And Ep-602-vwa00358.pdf, And 2) Change The Rfp Closing Date And Time From Thursday, July 30, 2020 At 1:00 Pm Pdt To Tuesday, August 4, 2020 At 1:00 Pm Pdt.
the Electrical Drawings Can Be Found In Shared Google Drive, Contractor Solicitation Documents > Technical Questions And Responses (ppi Log). this Solicitation Is Total Small Business Set-aside. far 52.219-6 Limitations On Subcontracting Applies To This Solicitation. Please See Solicitation For Further Information On Percentage Applicability. pre-proposal Conference & Site Visit: July 14, 2020 @9:00 Am Pdt
location: Nakamura Courthouse Lobby Checkin 1010 5th Ave Seattle, Wa 98104 the Attached Solicitation Provides Additional Instructions For Rsvp. this Procurement Will Be Advertised Under North American Industrial Classification System (naics) Code 238220 - Plumbing, Heating, And Air-conditioning Contractors. The Small Business Size Standard For Naics Code 238220 Is $16.5m In Average Annual Receipts Over The Past Three (3) Years. general Information
the Seattle U.s. Courthouse Is Located At 1010 5th Ave Seattle, Wa 98104. project Background/description: the Nakamura U.s. Courthouse Is Located At: Nakamura Courthouse 1010 5th Avenue Seattle, Wa 98104 this Project Is Being Undertaken To Increase The Efficiency Of The Cooling Equipment At Nakamura Courthouse, Specifically During The Lower Load Cooling Hours Of The Year (spring And Fall, As Well As Early Cool Summer Mornings). Presently, The Central Plant Has Two 200 Ton Centrifugal Chillers, Which Are Not Able To Meet The Lower Loads Without Excessive Short-cycling. Presently, During The Peak Cooling Season, One 200-chiller, At Part Load, Can Maintain The Cooling Load Of The Building. project Scope: design And Construction For The Addition Of One Variable-speed-compressor Jockey-chiller To Satisfy The Shoulder Season And Early Morning Cooling Loads Of The Nakamura Courthouse Building. The New Chiller Shall Be Mechanically Connected To The Existing Cooling Plant, And Controlled By The Existing Building Automation System. The Building Cooling Sequence Of Operation Shall Be Modified To Incorporate The New Jockey Chiller, As The First Stage Of Cooling For The Building, As Well As Provide Trim Capacity, Or Third Stage Cooling, If Needed. see Attached Statement Of Work For Detailed Information. responses
upon Receipt Of Solicitation Package, Interested Vendors Shall Complete And Sign, Sbu Agreement Exhibit 0 And Return With Attachments To Contract Specialist, Jong.kim@gsa.gov And Contracting Officer, Kimberlym.johnson@gsa.gov . Interested Vendor Shall Create A Gsa.google Email Account Via Gaca Instructions Atteched For Access To Sbu Documents. . Interested Vendor Shall Create A Gsa.google Email Account Via Gaca Instructions Attached For Access To Sbu Documents. Technical Documents Will Not Be Released Via Beta.sam.gov. The Gsa Google Drive Will Be The Primary Project Location For The Ppi Log, Specifications And Drawings, Photos And Any Additional Information. The Solicitation Attachments Will Also Be Uploaded To The Google Drive Due To Storage Capacity Through Email And Beta.sam. qualified Interested Small Business vendors Shall Submit Their Completed Proposals Per The Instructions Located In The 47pl0120r0015 solicitation Package. Rfp Packages Shall Be Sent In Electronically Only. responses Shall Be Emailed Not Later Than The Date Specified In This Solicitation Notice As Follows:
jong.kim@gsa.gov And Kimberlym.johnson@gsa.gov. response Date:
august 4, 2020 1:00 Pm Pdt
all Interested Vendors Are Required To Respond To This Solicitation Notice Via Email Not Later Than 1:00 P.m. Pdt, August 4, 2020.
PUBLIC BUILDINGS SERVICE USA Tender
United States
Closing Date16 Oct 2020
Tender AmountRefer Documents
The Site Of This Project Is The Office Of The Solicitor Suite Located At The Federal Office Building At 2800 Cottage Way In Sacramento, Ca. the Intent Of This Project Is To Complete Various Improvements To Office Suite E-2807 Of The Project Address. The Federal Office Building Is Owned By The Federal Government, And It Is Not Subject To The Requirements Of The Local Building Department. However, All Local, State And Federal Codes Need To Be Followed.
this Project Is A total Small Business Set-aside (far 19.5). to Be Eligible For Contract Award, Offerors Must Be Registered In The System Management (sam), Which May Be Found At Ww.sam.gov/. All Interested Parties Are Cautioned To Ensure That Information Listed In Sam Is Current And Correct. site Walk Will Be Conducted On Thursday, October 1, 2020 With Project Manager, Margo Jaime. Site Walk Will Begin at 10:00am local Time In Lobby Of Building. Information For registering For The Site Walk Can Be Found In The Attached Solicitation. Please Confirm Attendance Of The site Walk With Margo Jaime At Margo.jaime@gsa.gov. deadline to Submit Questions Is Friday, October 9, 2020 at 4pm Pst. the Basis Of Award Is Lowest Price Technically Acceptable. vendors Are Required To Send Proposals/questions To Both The Primary And Secondary Points Of Contact As Well As David.gardner@gsa.gov.
PUBLIC BUILDINGS SERVICE USA Tender
United States
Closing Date5 Feb 2021
Tender AmountNA
15 Years, 10 Years Firm, Loading Dock Required (flex/industrial/warehouse Space Is An Option, Please Submit Site Control With The Expression Of Interest) North Boundary
Broward Blvd. East To I 95
Broward Blvd. West To I 595 To I 75 To Us 27
East Boundary
I 95
West Boundary
Us 27
South Boundary
County Line Road East To I 95
County Line Road West To Hiatus Rd.
Hiatus Rd. North To Pines Blvd.
Pines Blvd. West To Us 27 (see Map) 3500 Aboa Sf Min And 4600 Aboa Sf Max requirements laboratory Needs: restricted Access With Card Key Capabilities; entry Double Door Entry, Pocket Doors Or Swing Doors Preferred; positive Air Flow And Separate Ventilation To Outside; sloped Floor And Gutter Drains Along The Center Or Mid-center Of The Room; overhead Direction Ceiling Fans And Retractable Outlets; water Hose Spigot For Floor Wash Down; And wall Or Overhead Retractable Water Hose Reel Near Water Hose Spigot. sensory Booths Within The Laboratory Needs: 10 To 15 Partitioned Sensory Booths Of Smooth, Non-porous Material Easy To Clean; open Flow Designed To Allow Sensory Booths And Traffic Flow From Booth To Booth; positive Air Flow And Separate Ventilation To Outside; floor Drain; And stainless Steel Sink And Counter. main Office Areas Should Include: stove With Ventilation Hood; stainless Steel Sinks (4 Desired); dishwasher With Disposer, And Trash Compactor/disposer; And be Adjacent To The Freezer, Cooler, And Ice Machine Room. office Space Should Be Adjacent Freezer, Cooler And Ice Machine Room. need 24hr Secured Parking With Security Cameras With Retrievable Data. backup Generators For Inspection Coolers, Freezers, And Offices. dumpster Location And Design: located In An Area Which Will Not Cause Off Odors To Penetrate Building; include Outside Water Spigot With Anti-siphon Backflow Protection For Water Hose; And include Ground Gutter Drain Located Near The Dumpster, For Wastewater Drainage During Dumpster Cleaning Activities. south Florida Lot Inspection Office specifications grounds Area 24hr. Access For Inspectors And Customers security Cameras For Parking And Entrance With Retrievable Data secured Parking (preferably Free Parking) For 24 Noaa Employees And/or Gsa Leased Vehicles With Lighting During Night Times backup Generators For Inspection Coolers, Freezers And Office Activities dumpster Location And Design located In An Area Which Will Not Cause Off Odors To Penetrate Building outside Water Spigot With Anti-siphon Backflow Protection For Water Hose ground Gutter Drain Located Near The Dumpster, For Waste Water Drainage During Dumpster Cleaning Activities entrance Areas pest Entry Preventing Mechanisms (e.g. Air Curtains, Plastic Curtains; Especially Needed At Laboratory And/or Kitchen Entrances) sufficient Entrance Way/corridor Which Would Allow For Furniture (e.g. Sofa, Table And Lamp) For Waiting Area For Customers division Between Waiting Area And Lot Inspection Office (i.e. Locked Door, Lockable Slide Glass Window With Reach Through To Deliver Certificates To Customers) non-skid Flooring routine Cleaning Services Under Contractual Services For This Area common Areas all Common Areas Such As Customer Waiting Area, Walkways Between Designated Rooms, Entrance Way Or Exit Ways Subject To Routine Cleaning Services Under Contractual Services handicapped Access Per Gsa/opm Guidelines non-skid Flooring office Areas (supervisory And Admin.) primary Office 1 office Area (inspectors) And Conference Room primary Office 2 4 Small Enclosed Offices 576sf (12’ X 12’sq Ft.) For 3 Supervisory Personnel And 1 Admin. Personnel) (i.e. With Closeable And Lockable Doors, Preferably With Window To Outside) electrical Outlets ethernet Or Wireless Capabilities telephone Capabilities routine Cleaning Services Under Contractual Services For This Area 2000sf (~42.43’ X 42.43’sq Ft.) This Space To Include An Enclosed Room Within A Room (i.e. The Conference Room): 1 Inspector’s Room (open Designed) With Space For Approximately 20 Individual Workstations (e.g. Cubicles Or Dividers With Individual Desks And Lockable Storage Cabinets And File Storage; Each Cubicle Area Or Division Shall Have: electrical Outlets ethernet Or Wireless Capabilities telephone Capabilities routine Cleaning Services Under Contractual Services For This Area 1 Conference Room File Cabinet Storage (enclosed) Shall Have: video Conference Capabilities electrical Outlets ethernet Or Wireless Capabilities telephone Capabilities routine Cleaning Services Under Contractual Services For This Area all Office Areas To Be Outfitted With: restricted Access (card Key Capabilities) wifi Or Cable And Router Capabilities electrical Outlets At Both Floor Level And Higher Levels For Monitors Etc. cable Router Capable on Site It Assistance With Administrative Privileges non-skid Flooring laboratory lab & Clinic Sp 1 approximately 625 Sq. Ft. (25’ X 25’sq Ft.) restricted Access (card Key Capabilities) entry Double Door Entry, Pocket Doors Or Swing Doors Preferred positive Air Flow And Separate Ventilation To Outside sloped Floor And Gutter Drains Along The Center Or Mid-center Of The Room water Hose Spigot For Floor Wash Down wall Or Overhead Retractable Water Hose Reel Near Water Hose Spigot retractable Overhead Electrical Outlets overhead Directional Ceiling Fans ample Number Of Above The Counter Electrical Outlets For Appliances Stored On Counter Tops ample Number Of Lower Level (near Floor) Electrical Outlets wifi Capability / Cable And Monitor Connections telephone Capabilities adjacent To Freezer, Cooler And Ice Machine Room non-skid Flooring overhead Lighting (led Northern Light) preferably 10 Ft. Ceiling to Contain: stove With Ventilation Hood double Basin Stainless Steel Sinks (basins Position Below The Counter With Hot And Cold Water Source; (preferably 4 Sinks) With Hot And Cold Water Source Ideally 2 Small Sinks Along Counter Wall With (adequate Spacing Between Faucet And Wall Surface For Hand Washing) And 2 Large Sinks (commercial Sized Sinks) Positioned In The Center Of The Room With Overhead Or Pull Down Spray Attachments dishwasher/ With Sink Disposer trash Compactor/disposer lower Cabinets With Legs (off The Floor) For Storage (lockable) wall Cabinets For Storage (lockable) stainless Steel Or Corian Countertops microwave Ovens (commercial) 3 Or More fisher Scientific Timers fire Alarm And Fire Extinguishers eye Wash Station freezer, Cooler And Ice Machine Room general Storage St 1 approximately 300 Sq. Ft. (15’ X 20’sq Ft.) adjacent To Freezer, Cooler And Ice Machine Room room Of Sufficient Size To Hold 3 Upright Freezers room Of Sufficient Size To Hold 2 Upright Coolers room Of Sufficient Size To Hold 1 Upright Stand Alone Ice Machine room Outfitted With Proper Wattage And Plugs For Appliance Listed Above back Up Generators For Freezers And Coolers (see Grounds Area) room Outfitted For Drainage For Ice Machine non-skid Flooring floor Drain sensory Room conference & Training Sp 5 approximately 600 Sq. Ft. (20’ X 30’sq Ft.) restricted Access (card Key Capabilities) 10 To 15 Partitioned Sensory Booths Of Smooth, Non-porous Material Easy To Clean, (no Pressed Wood); Preferably Stainless Steel Or Corian Counters open Flow Designed To Allow Sensory Booths And Traffic Flow From Booth To Booth positive Air Flow And Separate Ventilation To Outside floor Drain ample Number Of Above The Counter Electrical Outlets For Appliances Stored On Counter Tops ample Number Of Lower Level (near Floor) Electrical Outlets wifi Capability / Cable And Monitor Connections telephone Capabilities non-skid Flooring overhead Lighting (led Northern Light) preferably 10 Ft. Ceiling to Contain: 1 Small Double Basin Stainless Steel Sink (basin Position Below The Counter With Hot And Cold Water Source; With (adequate Spacing Between Faucet And Wall Surface For Hand Washing) lower Cabinets With Legs (off The Floor) For Storage (lockable) wall Cabinets For Storage (lockable) stainless Steel Or Corian Countertops lot Office Scheduling Room office Support Area 1 approximately 144 Sq. Ft. (12’ X 12’sq Ft.) all Office Areas To Be Outfitted With: restricted Access (card Key Capabilities) wifi Or Cable And Router Capabilities electrical Outlets At Both Floor Level And Higher Levels For Monitors Etc. cable Router Capable telephone Capabilities on Site It Assistance With Administrative Privileges non-skid Flooring considerations (dry Erase Paint For Entire Wall Or Sections Of A Wall) For Use In Scheduling Activities considerations (black Board Paint For Entire Wall Or Sections Of A Wall) For Use In Scheduling Activities overhead Monitors Or Wall Monitors For Use In Scheduling Activities restrooms designated Restroom For Female Employees With At Least Two Stalls designated Restroom For Male Employees With At Least Two Stalls And One Urinal routine Cleaning Services, Paper Supply And Hand Drying Under Contractual Services For These Restrooms floor Drain break Room food Service Area Sp2 approximately 144 Sq. Ft. (12’ X 12’sq Ft.) break Area To Be Outfitted With: restricted Access (card Key Capabilities) to Contain Double Basin Sink With Disposal to Contain Large Refrigerator electrical Outlets At Both Floor Level And Higher Levels For Electrical Etc. wifi Or Cable And Router Capabilities on Site It Assistance With Administrative Privileges non-skid Flooring floor Drain locker Room office Support Area 2 approximately 144 Sq. Ft. (12’ X 12’sq Ft.) locker Room To Be Outfitted With: restricted Access (card Key Capabilities) space Adequate For 20 Vertical Lockers 1 Or 2 Electrical Outlets At Floor Level non-skid Flooring floor Drain misc. Closets And Storage warehouse Storage St2 67 Sq. Ft totals Square Footage 3500 Aboa Sf Min And 4600 Aboa Sf Max