Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Ministry Of Micro Small And Medium Enterprises

  • Opening Date

    05 Aug 2019

  • Closing Date

    14 Aug 2019

  • Tender Amount

    Refer document

  • EMD

    -

Are you Looking for Joint Venture Partners, Contractor Consortium, Project Financiers for this tender?
We will help YOU to find the right match for FREE!
Summary

Breath Alcohol Analyzers

Are you looking for Materials and Services for this tender?
We will help YOU to find the right partner for your needs for FREE!
BOQ Items

No BOQs Available

Providers

No Providers Available

Seekers

No Seekers Available

Bid Number: GEM/2019/B/312741 Dated: 05-08-2019 Bid Document Bid Details Bid End Date/Time 14-08-2019 11:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 75 (Days) Ministry/State Name Delhi Department Name Home Department Delhi Organisation Name N/a Office Name Tihar Jail Total Quantity 14 Item Category breath alcohol analyzers MSE Exemption For Years Of Experience And Turnover Yes Startup Exemption For Years Of Experience And Turnover Yes Bid to RA enabled No Breath Alcohol Analyzers ( 14 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TECHNOLOGY / PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * Measuring Range [mg / 100 ml BAC (Blood Alcohol Concentration)] 0 to 500 0 to 500 1 / 7 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg / 100 ml BAC) 2 0.0 - 2.0 Or lower Easily replaceable mouthpiece with Sputum Trap yes * Sample Taking Duration 5 * Analytical Response Time (At '0' level of Alcohol) 3 * Analytical Response Time for positive result 15 * Recovery Time at (1/2) mg/ltr 30 * Warm up Time (after putting on) 15 * Time required for re- calibration 12 * Barometric Pressure Range (hpa or millibar) 1300 * Shelf Life of Fuel Cell 3 * RoHS Compliant Yes * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements Yes * PHYSICAL Weight 320 * Size ( mm x mm x mm ) - * BATTERY OF ANALYZER Power Source Rechargeable Battery and also work through automobile 12 V DC Power. * Chemistry of Rechargeable Battery Li-ion * Battery Voltage 7.4 * Battery Backup Time (continuous duty) 24 * Number of Spare Rechargeable Batteries supplied with the 0 * 2 / 7 instrument Low Battery indication yes * DISPLAY / INDICATOR / STORAGE / INTERFACE Display Type TFT LCD * Display Size 3.5 * Availability of audible beeper for over range, low battery etc yes * Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen Minimum Record Fields Full Information as per the user's requirement such as Driver Name, Vehicle number, inspector name, test report with time, date, geolocation, instrument id, etc * Record Memory (Minimum) 50000 50000 Record Data Downloadable to PC yes * Data Interface USB,Bluetooth * GPS Yes * If yes, Capable to display the geolocation of test inspection / location yes * Camera No Yes, No If yes, Capable to capture the clear image of test target NA * PRINTER Printer With With Type of Printer Internal Thermal Printer Internal Thermal Printer Print Resolution (dpi) 203 * Printer consists of Inbuilt Rechargeable Battery, Paper for offence printouts, Charger yes * Minimum number of printouts that can be taken with the paper available with the Printer 100 * "Minimum number of printouts that can be 100 * 3 / 7 taken with single charge of the printer battery (Hint:- Minimum 60 prints, if 'With Printer' May indicate '0' if not applicable)" Bis Registration number for Printer under CRS of MeitY - * WARRANTY Warranty 2 2, 3, 4, 5 Or higher STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement, The instrument is hand held, portable and easy to operate Yes * If Yes, the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface,meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature -10 * Maximum Operating Temperature 55 * Relative Humidity Non Condensing (%)

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.