Zilla Parishad Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date16 Aug 2024
Closing Date23 Aug 2024
Tender Amount₹ 4,02,219
Costs
EMD
₹ 8,044Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ZPHD_735144_1Bid Award Id
ViewTender No
NleT-08/BBGP/2024-25(2nd Call)Tender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (b) River bazree
0.4
1526
3815.71
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (ii ) River Bazree
3.89
17507
4497.14
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (b) With earth obtained by fresh excavation (including cost of excavation upto 1,800 mm. depth) from land arranged by the Deptt. within a lead of 100 m.
2.4
329
137.18
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m II. Other than SAIL/ TATA/RINL
0.44
25369
58250.5
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,
lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of
Engineer-In-Charge
41.58
13638
328
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
10.43
6967
668
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] ii) with 1:4 cement morter ( b) 15 mm thick plaster
69.35
10610
153
Neat cement punning about 1.5 mm thick in wall, dado, window sill, floor etc.
12.51
408
32.68
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (iii) Two coats
63.44
3108
49
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the samecomplete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.
(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. (ii) 100 mm dia. boring etc. top enlargement
426
23856
56
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).i) 100 mm dia PVC (ASTMD)
56
48944
874
ii) 32 mm dia PVC (ASTMD)
58
9802
169
iii) 25 mm dia PVC (ASTMD)
6
726
121
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. iv) 100 mm dia. i) 100 mm dia PVC Stainer
6
4068
678
Solar Module: Supply, transport, installation and commissioning of lSI marked as per IS 14286 and IEC 61853(1). 61730(1&2), 61710 certified Solar Module of Multi crysta lin elM anocrvs tilIIine/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity .3.2/4: mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. (As per direction of EIC)TATA/WARRAR/ ADANI/ BIKRAM or equvalant.
c)For 1 HP Off-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 900-1200 Wp.
1200
38748
32.29
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity
1
10434
10434
Module mounting structure (for 1HP, 2HP, 3 HP, 5 HP and 10HP solar water pumping system): Supply , transportation and installation of GI manual tracking structure made of MS hollow section, pipe, plate, angles, etc. as per IS:1161/1239, 1079/2062, to hold min 300Wp SPV modules as per drawing and specification of MNRE. This steel structure is to be protect with minimum 80 micron galvanization (hot dip) and provided with fixed arrangement or dual axis manual tracking arrangement for three times in a day and seasonal tilting are to be regulated to face the sun optimally (as per requiremnt) .
18
2610
145
Testing and commissioning of scheme after completion of all work.
1
2000
2000
1Hp 3 Phase AC surface mounted monoblock Pump-Motor set as per IS9079with discharge of 4.0-5.0 Lps a8 mts. Total head with ,requred quantity of fexibl delivery pipe (10am) clamps, cable and all others accessories to complete connection of suction and delivary side.
1
18155
18155
Lightning protection (pole mounted): Lightning protection with 1.5" GI Pipe of 4 mts + 0.75 mts height with base flange in proper RCC foundation and S&F lightning conductor air terminal made of 20 mm dia 1000 mm long GI Pipe (ISI Medium) having five discharge prongs of 4SWG GI (hot dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom including necessary holes etc. Earthening with 65 mm dia GI pipe (medium) 3.0 mts long and 1X19/10 standard GI (HotDIp) wire (4mts long) 20 mm dia X 12 mm long galvanized bolt double nut, double wadshar including socketing at voth end of standard GI (Hot Dip) wire by crimping sockets/ thmbles and S&F 65 mm GI pipe (ISI-Medium) propection (3 m long ) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 mts (provosion of one lightning protection for each structure)
1
6725
6725
Earthing:- Earthing with 50mm dia GI pipe 3.64 mm thick X 3.04 mts long and 1X4 SWG GI (Hot Dip) wire (4mts long ) , 13 mm dia X 80 mm long GI bolts, double nuts, double washar including S&F 15 mm dia GI pipe protection (1 m long) to be filled with bitumen partly nder the ground level and partly above ground level driven to an average depth of 3.65 mts below the ground levle as below:
By ISI -Medium GI pipe including excavation of soil for installation of earth electrodes and filling and ramming and connecting to individual structure to earth electrode including S&F 20 mm X 3MM galavanized ( Hot Dip) MS flat on wall/ floor with GI saddle as required and connection to equipment including drilling holes, with bolts, nuts, washar etc.
1
2661
2661
Supply, Fitting and fixing in position at site including carriage, Iron Removal Filter, capacity 3000 Liter Per Hour, with ISI mark of TATA/APEX.
2
57000
28500
Supply, transport, installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine. condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc. The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRSbased data transmission.Amrit/Havels/Suriya or equvalant.
b) For 1 HP capacity Pump-motor set. (As per direction of EIC)
1
19056
19056
Cable and Accessories: Supplying, fitting and fixings of UV rated Copper Cable laid inside HOPEconduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.
i. 4.0 Sq mm single core multi studs - 10 Mtrs (Minimum) ii. 6.0 Sq mm single core multi struds -5 Mtrs (Minimum) iii. Lugs, HOPEPipe, Flexible Pipe, Saddle, Cable, tie etc
a) For1 HP per structure (As per direction of EIC) W.R.I D.D. Schedule of Rates 2021,ch. 12, item no. 4
1
1134
1134
(As per Building schedule) (With effect from – 01/11/2017) Page-51, Item-10.A.i., 20 mm. thick (finished) terrazo work with precast tiles set on 20 mm avg thick cement mortar (1:3) and sides with admixture of pigment and white/grey cement as necessary in floor, dado,skirting, staircase etc. laid in panels or in patterns including high polishing, raking out joints, roughening of concrete surface & application of cement slurry before flooring works using cement @ 1.75 kg. per sq.m. all complete including all materials & labour.
6.27
5657
902
Supply fittings & fixing of Display Board at site.
1
2350
2350
Add CGST & SGST @ 18%
337488.35
60747
0.18
Labour welfare cess @ 1%
398236.25
3982
0.01
Evaluation Notes How It Works ?
Potential Partner