Zilla Parishad Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date22 Jun 2024
Closing Date2 Jul 2024
Tender Amount₹ 3,49,986
Costs
EMD
₹ 7,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ZPHD_698281_2Bid Award Id
ViewTender No
eNIT-02/KGP/MAL/2024-25(2nd Call)Tender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://http://jalpaigurizp.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
PWD S&P SCHEDULE, PAGE NO. 53, ITEM 10(ii)
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (ii) 50 mm
1
71
71
PWD S&P SCHEDULE, PAGE NO. 53, ITEM 12(vi)
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. (vi) 50 mm
1
2203
2203
PWD S&P SCHEDULE, PAGE NO. 54, ITEM 17(i)
Supplying, fitting and fixing heavy type bell mouth reducing socket. (i) 50 mm X 100 mm
1
455
455
PWD S&P SCHEDULE, PAGE NO. 56, ITEM 27
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
1
2235
2235
PWD S&P SCHEDULE, PAGE NO. 102, ITEM 1
Supply of G. I. pipes of TATA make including necessary sockets (d) 32 mm dia. (ii) Medium quality
12
3072
256
(f) 50 mm dia. (ii) Medium quality
21
8442
402
(i) 100 mm dia. (i) Medium quality
20
16600
830
PWD Building SCHEDULE, Page - 99 / Item -1
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
0.7
42161
60230
PWD Building SCHEDULE,Page - 1 / Item -2
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
6.62
789
119.27
PWD Building SCHEDULE,Page - 35 / Item -22. II)
(II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety In ground floor
0.91
3087
3393
PWD Building SCHEDULE,Page - 26 / Item -10. ii)
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River Bazree
1.71
8113
4745
PWD Building SCHEDULE,Page - 42 / Item -36. Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
10
3280
328
PWD Building SCHEDULE,Page - 43 / Item -40. Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel II. Other than SAIL/TATA/RINL
0.2
13100
65502
PWD S&P SCHEDULE,Page - 29 / Item -a) ii)
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (ii) CPVC Pipes Class-2,SDR-13.5 From Storage Tank to Stand Post 25 mm
24
4320
180
PWD S&P SCHEDULE,Page - 37/Item -6 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1500 litre capacity
1
7840
7840
PWD S&P SCHEDULE,Page - 7 / Item -7. g)
(g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. (i) 15 mm
2
338
169
PWD Building SCHEDULE,Page - 200/Item -1. a)
((b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
20
580
29
PWD Building SCHEDULE,Page - 200 / Item - 2. b) iv)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
20
1580
79
WRDD SCHEDULE,Page - 109 / Item - 1(b)
Supply , transport , installation and commissioning of Solar PV installation for water pumping system with fixed structure consisting of solar panels framed in anodized aluminium frame mounted on stable hot dipped galvanized (with 80 micron thickness) mild steel structure of sufficient strength which can withstand load of modules and high wind velocities upto 150 Km/hr, having RCC foundation designed against all possible loads (Dead, Live and imposed load). Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent National or International standards and must be interconnected with 4/6 sq.mm cables routed in PVC conduits properly fitted along the G.I structure to provide a good aesthetic view. Modules must qualify to IEC 61730 part I and part II for safety qualification testing. The power output of individual PV modules used in the PV array, under STC, should be a minimum of 250 Watts peak, with adequate provision for measurement tolerances. Solar cells should be crystalline silicon cell with min. efficiency of 14% and fill factor more than 70%, should be laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass including appropriate DC to AC inverter and power controlling unit (protected with IP65 class enclosure) with MPPT technology to run at low sunshine and minimum 5 hours a day run with all necessary accessories suitable for solar + grid operation and including all protections of AC induction motor pump. There should be a display of all measurable parameters including storing of data at a set interval and transfer it in a pendive thru USB port . There should also be provision of interfacing GPRS based data transmission. (The rate is inclusive of manufacturer's warranty and comprehensive maintenance for 1st year and comprehensive maintenace for 4 years beyond Ist year)
1050
121800
116
WRDD SCHEDULE,Page - 114 / Item - 2(i)
Supplying , fitting and fixing of Sand Filter - Manual as per IS:14606 Sand Filter10m³/hr-M Single
1
17192
17192.81
PWD Electrical SCHEDULE,Page - G-1 / Item - 2. a
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
1
1464
1464.83
PWD Electrical SCHEDULE,Page - G-2 / Item - 5. a(i)
Connecting the equipment to the earth busbar incl. S&F GI wire of size bellow on wall /floor as required and making connection to the equipment with bolts, washers, cable lugs etc. as required and mending good damages. No 4 SWG GI wire
20
385
19.26
WRDD SCHEDULE,Page - 80 / Item - 2(b)(i)
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (b) 30 cubic metre per hour capacity electro motor pumping set. (i) Length of pump assembly not exceeding 18 metre length
1
617
617
WRDD SCHEDULE,Page - 77 / Item - 18
Supplying 1 m × 0.6 m × 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
1
1000
1000
Supply of 1 HP oil fill AC solar submersible pump motor set complete having suitable dischage as per yeld test of well. Submerisble cable of 30mtr 3 core 2.5 sqmm that cable (Finolex) with MOC bar chart (Kriloskar make Pump) (Rate As per Quotation)
1
12500
12500
Add:- GST @ 18%
1
52859
52859.05
Add:- Cess @ 1%
1
3465
3465.2
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements