West Bengal Electronics Industry Development Corporation Limited Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal Electronics Industry Development Corporation Limited - WEBEL Tender
Civil And Construction
Eprocure
Opening Date12 Jun 2023
Closing Date18 Jul 2023
Tender Amount₹ 1,33,00,000
Costs
EMD
₹ 2,66,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
07 Webel Idm Icp Up Gradation 23 24 04
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_WEBEL_541487_1Bid Award Id
ViewTender No
07/Webel/IDM/ICP/Up gradation/23-24/04Tender Authority
West Bengal Electronics Industry Development Corporation Limited ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation.
19
-
-
... More
Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
160.5
-
-
... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
37.55
-
-
... More
Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 20 Grade.
64.2
-
-
... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/. All floor
4.05
-
-
... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
(i) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.
116.5
-
-
... More
Supplying & laying Polythene sheet (150gm/sqm.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
375.5
-
-
... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:4 cement mortar (a) 15 mm thick plaster
250
-
-
... More
Brick work with 1st class bricks in cement mortar (1:4). In foundation and plinth ). In foundation and plinth.
30
-
-
... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
280
-
-
... More
Providing and fixing (Cutting Electrical light or other fixture) of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U- 1520)
130
-
-
... More
SANITARY & PLUMBING WORKS
-
-
-
... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) Class-1, SDR-11 pipes of approved make conforming to IS-15778:2007 with all necessary accessories, specials viz. socket,bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials 15 mm
20
-
-
... More
20 mm
30
-
-
... More
25 mm
75
-
-
... More
32 mm
400
-
-
... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 20 mm dia
10
-
-
... More
25 mm dia
10
-
-
... More
32 mm dia
10
-
-
... More
40 mm dia
10
-
-
... More
50 mm dia
25
-
-
... More
Supply and fixing of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 110 mm Single Socketed 3 Meter Length
20
-
-
... More
Supply and fixing of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 75 mm Single Socketed 3 Meter Length
20
-
-
... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety.
10
-
-
... More
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). (i) 900 mm X 750 mm (inside) chamber i) With Pakur variety.
5
-
-
... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.
(i) For 10 users
5
-
-
... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.
With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.
5
-
-
... More
Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm. (i) 50 mm
10
-
-
... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid - 3 layer including lifting charges and making hole of required dia. (i) 1000 litre capacity
5
-
-
... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of
1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (i) 100 mm dia. R.C.C. pipe
10
-
-
... More
TOILET CABIN:
Supplying, installing, fitting, fixing, and commissioning of a prefabricated Portable Toilet with two spacious compartments, each measuring 4 ft x 4 ft. The cabin features a corrugated exterior wall made of Cold Rolled Close Annealed (CRCA) material, coated with a red oxide primer and finish paint for enhanced protection. To ensure the interior roof and walls are covered with 4mm thick Aluminum Composite Panel (ACP). The container floor consists of a water proof vinyl mat layered over 18mm thick cement fiber board, and the container itself has a thickness of 1.2mm. The cabin comes in a Phiroza Blue color and includes small exhust louver for ventilation, sliding glass. The main entrance door is a single leaf type measuring 6ft x 2ft, made of UPVC and includes door lock, and small canopy. Additionally, sanatary & Plumbing fittings with proper Sanitary line with proper plumbing line in all respect for WC compartment ( water Closet- 1no, cistern-1 nos, bip cock-1 nos, health fauset-1 no, soap Container-1no, toilet paper Holder-1no and other fittings) and for bathroom Compartment ( Wash Basin-1nos, pressmatic pillar cock -1no, Urinal Pan- 1no, pressmatic Angular stop cock -1nos, Mirror-1nos, towel Rail - 1No, soap Container-1no and other fittings), The provided rate is inclusive of all items as mentioned above and other accessories from an approved brand. The cabin can be installed at any location as specified in the Special Conditions of Contracts. The number of doors, windows, exterior colour and furniture details are to be approved by the Engineer in Charge. Electrical : Each compartment shall be complete with necessary concealed electrical wiring, switchboard for controlling 1 no. LED lamp holder & 1 no. exhaust fan. Wiring shall be carried out through rigid PVC conduit and 1.5 sq. mm. FRLS PVC Cu. wire. The rate shall be inclusive of electrical sw-socket, fittings etc. (1no. 9 Watt LED Lamp & 1 no. 100mm. Exhaust Fan).Each cabin shall be fitted with 1 no. 11W LED Bulhhead fixture at outside.
5
-
-
... More
BORE WELL
-
-
-
... More
Part A
-
-
-
... More
Installation of 1 No 250 mm x 150 mm dia Tubewell along with providing, testing and commissioning of Submersible pumpset
-
-
-
... More
Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system including hire charges and labour for supplying of suitable dia. Casting pipes upto full depth of tube well with necessary sockets, tools and plants, staging, force pumping set and making necessary arrangements for boring and also cost of withdrawing the casing pipes and lowering pipes, stainers, blind pipes etc. complete. (The casing pipe should have a minimum 50 mm gap in between the outside of the tube well pipe and the casing pipe).
-
-
-
... More
a) For depth upto 150 meter for 150 dia. Tube well with top enlargement of 250 mm dia.
-
-
-
... More
i) First 50 metre
250
-
-
... More
ii) Next 50 metre
250
-
-
... More
iii) Rest 50 metre
250
-
-
... More
iv) For additional depth beyond 150 m
50
-
-
... More
Supplying PVC strainer of approved make with adapter conforming to I.S.12818specifications.
-
-
-
... More
i) 150 mm dia.
750
-
-
... More
Supplying, fitting & fixing heavy type bell mouth PVC reducing socket
-
-
-
... More
200 mm X 250 mm
5
-
-
... More
Nipple (300 mm long), Dia 150mm
5
-
-
... More
Supplying, fitting and fixing G.I. cap at top
-
-
-
... More
300 mm
5
-
-
... More
Supplying, jointing and lowering vertically uPVC threaded pipes with necessary sockets, special fittings and jointing as required including cost of all jointing materials, hire charges of tools and plants, cutting pipes to required sizes with threads as necessary and lowering the pipes within the borewell vertically as per direction of the Engineer-in-charge
-
-
-
... More
150 mm nb Sch 80 and as per ASTM D1785
600
-
-
... More
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yeild in gallons per hour with "V" notch including hire and labour charges for all tools and plants and scaffolding as required complete in all respect.
10
-
-
... More
Labour for making arrangement for showing vertically test including the cost for hire charges of tools and plants, scaffolding labour etc. all complete.
5
-
-
... More
Collecting sample of water for physical bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc, complete in all respect as per direction and as per IS 10500 parameters.
5
-
-
... More
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having sizefrom 2 mm to 5 mm or the size aproved by the Engineer - in- charge including cost of materials labour and equipment complete.
10
-
-
... More
Packing the annular space between the outside of the housing pipe & the bore with puddled clay balls of approved size as per direction of the Engineer - in- charge with cost of materials & labour complete.
10
-
-
... More
Providing & fixing bottom plug as required for 150 mm dia PVC pipe including cost of materials & labour with fixing in position complete for sealing the bottom of assembly.
5
-
-
... More
Supplying, fitting & fixing 300 mm M.S housing clamp of approved quality
5
-
-
... More
Providing 200mm centre guide.
5
-
-
... More
Geophysical investigation of the aquifer by electro logging system with all tools & plants as necessary including supply of necessary report.
5
-
-
... More
Construction of brick masonary water tight chamber of required size for tubewell with 150 mm thick cement concrete bed with stonechips over a single layer brick flat soling, 250 mm thick cement brick work (1:6) 19 mm cement plaster (1:6) with neat cement finish both inside and outside precast openable RCC slab of required thickness on top of the chamber including necessary excavation, refilling, shuttering and reinforcement complete. Size 1200 x 1200 x 900 m
5
-
-
... More
Part B : SUBMERSIBLE PUMPSET & ACCESSORIES
-
-
-
... More
2HP single-phase water submersible pump, of approve make is a versatile and efficient for applications to lift the water. With a head range of 77 to 163 meters and a discharge range of 1020 to 3000 liters per hour, this pump is capable of handling various water pumping requirements. It features 24 stages and operates at a speed of 2900 RPM, ensuring reliable performance. The pump is designed for single-phase power supply at 220V, providing a power rating of 2HP (1.50KW) with optimal efficiency. To operate the pump, Star Delta Starter, available in makes such as Havells, Crompton Greaves, Control & Switch Gear, BCH, and L&T Siemens, providing fully automatic operation. Additionally, spike earthing is provided to ensure the safety of the starter. With these features and considerations, this water submersible pump is a reliable choice for efficient water pumping tasks.
5
-
-
... More
Supplying, fitting and fixing 80 mm dia GI bend having one end threaded and socketed other end flanged with special arrangements for fitting and fixing pressure gauge.
15
-
-
... More
Supply fitting and fixing 100 mm dia pressure gauge (0 to 7 kg / sq cm minimum) with controlling cock and brass "U" syphon.
5
-
-
... More
Supplying, fitting and fixing electrical water level guard with two pole electrodes.
5
-
-
... More
Supplying of PVC pipe of approved make of 80 mm dia (medium quality) including necessary sockets for column pipe. 80 mm dia
600
-
-
... More
CI sluice valve with flanged ends drilled to as per IS 1358/1962 and having all cost component as per IS 780/1971 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT / sq.cm. spindle nut valve and seat faces of hardware resisting manufactured from best quality gun metal, conforming to IS 780/1971 paint tested to 21 kg. (Hydraulic Pressure) sq.cm. valve opening to anticlockwise direction fitted and fixed complete.
-
-
-
... More
80 mm dia
10
-
-
... More
Supplying, fitting and fixing CI non return valve with flanged ends drilled to as per IS 1358/1962 including necessary nuts and bolts, rubber insertion etc. complete (IS marked).
-
-
-
... More
80 mm dia
5
-
-
... More
Supplying, fitting and fixing wrought iron flange of approved quality with washer and bolts as per standard joints complete in all respects.
-
-
-
... More
80 mm dia
5
-
-
... More
Supplying, fitting & fixing approved brand 32 mm PVC waste pipe, with coupling at one end fitted with necessary clamps
750 mm long
10
-
-
... More
PORTA CABIN
-
-
-
... More
SECURITY CABIN:
Supplying, installing, fitting, fixing, and commissioning of a prefabricated portable security cabin measuring 6 ft x 8 ft x 9 ft. The cabin features a corrugated exterior wall made of Cold Rolled Close Annealed (CRCA) material, coated with a red oxide primer and finish paint for enhanced protection. To ensure thermal efficiency, the roof and walls are insulated with Glasswool (16 - 20 kg/m3), while the interior roof and walls are covered with 4mm thick Aluminum Composite Panel (ACP). The container floor consists of a vinyl mat layered over 18mm thick plywood, and the container itself has a thickness of 1.2mm. The cabin comes in a Phiroza Blue color and includes small canopy windows (3ft x 3ft) with aluminum frames, sliding glass, and MS grills for security. The main entrance door is a single leaf type measuring 6ft x 3ft, made of mild steel and includes a primer, finish paint, door lock, and small canopy. The material for the interior door will be specified based on requirements. Additionally, the interior furniture for the porta cabin includes a manager's table, full work station table, under-table cabinet, and wall-mounted cabinet, all made of prelam MDF. These furniture items are designed to provide functional workspaces and storage solutions within the cabin, ensuring a comfortable and organized environment for users. The provided rate is inclusive of all items as mentioned and other accessories from an approved brand. The cabin can be installed at any location as specified in the Special Conditions of Contracts. The number of doors, windows, exterior colour and furniture details are to be approved by the Engineer in Charge. Electrical: Each cabin shall be complete with necessary concealed electrical wiring, Sw-socket, switchboard for controlling 2 no. LED Tube Lights (seperately Controlled), 1 No. wall bracket Fan. Seperate sw. board for workstation with 3 no. 6 A Plug socket Controlled by 16A Switch, 1 no. 6/16A socket Controlled by 16A Switch shall be provided. Wiring shall be carried out through rigid/flexible conduit and 1.1kV 1.5/2.5 sq. mm. FRLSH PVC Cu wire. The rate shall be inclusive of necessary electrical switch socket and fittings (2 Nos. 20 Watt LED Tube Light & 1 no. 400mm. Wall bracket fan). Each cabin shall be fitted with 1 no. 11W LED Bulhhead fixture at outside.
15
-
-
... More
OFFICE CABIN:
Supplying, installing, fitting, fixing, and commissioning of a prefabricated portable office cabin measuring 20 ft X 8 ft X 8.5 ft. The cabin features a corrugated exterior wall made of Cold Rolled Close Annealed (CRCA) material, coated with a red oxide primer and finish paint for enhanced protection. To ensure thermal efficiency, the roof and walls are insulated with Glasswool (16 - 20 kg/m3), while the interior roof and walls are covered with 4mm thick Aluminum Composite Panel (ACP). The container floor consists of a vinyl mat layered over 18mm thick plywood, and the container itself has a thickness of 1.2mm. The cabin comes in a Phiroza Blue color and includes small canopy windows (3ft x 3ft) with aluminum frames, sliding glass, and MS grills for security. The main entrance door is a single leaf type measuring 6ft x 3ft, made of mild steel and includes a primer, finish paint, door lock, and small canopy. The material for the interior door will be specified based on requirements. Additionally, the interior furniture for the porta cabin includes a manager's table, full work station table, under-table cabinet, and wall-mounted cabinet, all made of prelam MDF. These furniture items are designed to provide functional workspaces and storage solutions within the cabin, ensuring a comfortable and organized environment for users. The provided rate is inclusive of all items as mentioned above and other accessories from an approved brand. The cabin can be installed at any location as specified in the Special Conditions of Contracts. The number of doors, windows, exterior colour and furniture details are to be approved by the Engineer in Charge. Electrical: Each cabin shall be complete with necessary concealed electrical wiring, DB, switch socket, AC plug socket with starter, electrical fittings and accessories as detailed below complete in all respect. Wiring shall be carried out through rigid conduit and 1.1kV 1.5/2.5/4 sq. mm. FRLSH PVC Cu wire. Following electrical items to be considered for each cabin:- i) 1 Nos. 2+10 Way SPN DB , ii) 1 no. 32A , 10kA C Curve DP MCB, 10 Nos. 6-32A C Curve 10kA MCB, iii) 6 Nos. 20 Watt LED Tube Light iv) 1 No. 25A AC Plug socket with Starter V) 4 Nos. 400 mm Wall bracket Fan , Vi) Sw. board for Work station with 3 Nos. 6A Plug Socket controlled by 16A Switch- 8 nos.vii) 2 nos. 6/16A plug socket controlled by 16A switch. Swich board to Fan /Light Shall be done by 1.5 sq. mm wire, DB to Sw. Board/ Plug Socket wiring shall be done by 2.5 sq. mm . wire, DB to AC starter shall be done by 4 sq. mm. wire. Each cabin shall be fitted with 2 nos. 11W LED Bulhhead fixture at outside.
4
-
-
... More
CHAIR
-
-
-
... More
Supply & assembling of Godrej Make Mid Back Chair- Model Earl Mid Back (7202R), Color Black. At any location as mentioned in Special Condition of Contracts.
56
-
-
... More
Supply & assembling of Godrej Make sofa
4
-
-
... More
ELECTRICAL & HVAC WORKS
-
-
-
... More
ENERGY METER
-
-
-
... More
Supplying & fixing of Three Phase Energy Meter (Single Source type) of Accuracy Class 0.5 and capable of measuring Voltage, Current, kWh.
5
-
-
... More
EXTERNAL FEEDER PILLAR BOX
-
-
-
... More
Supply, Installation, Testing & Commissioning of “External Feeder Pillar Box" with IP-65 class degree of protection, mounted on PCC pedestal. The rate shall be inclusive of civil works, 2 nos. spike earthing and all other mounting accessories as required, Cable incoming or outgoing shall be bottom. INCOMER: 1NO - 415V 63A 4P MCB (10KA) with RYB phase indicators BUSBAR: 63A, 10KA aluminium busbar OUTGOING: i) 6 NOS - 240V 6-32A 2P MCB (10KA), ii) 2 NOS - 415V 6-32A 4P MCB (10KA) EARTH BUSBAR: 1 Set - 25 mm X 3 mm GI busbar running along the base frame covering entire length of the panel with high tensile bolts, nuts, etc. and number of drilled holes as required for earth connection at both ends. 1 No. Danger Board
5
-
-
... More
MV CABLE
-
-
-
... More
Supply & laying of 1.1KV grade, A2XFY XLPE armoured Aluminium cable of following sizes with all necessary fttings & accessories required for installation. Rate shall include with 2 no. 8 SWG GI earth continuity wire for running earth and all civil work like cutting dressing mending good damages as required. Laying of cables will be done undeground / by existing electric poles (as per the direction of EIC)
-
-
-
... More
3.5 core 25 sq. mm.
300
-
-
... More
4 core 6 sq. mm.
75
-
-
... More
2 core 10 sq. mm.
250
-
-
... More
CABLE END TERMINATION
-
-
-
... More
Termination of below mentioned cable with Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of the cables and finishing the end of the cables by crimping method incl. supplying and fixing solderless socket, tapes, anticorrosive paste & jointing materials, lugs etc. as required.:
-
-
-
... More
3.5 core 25 sqmm
10
-
-
... More
4 core 6 sq. mm.
10
-
-
... More
2 core 10 sq. mm.
20
-
-
... More
STREET LIGHT POLE
-
-
-
... More
Supply & Erection of the following "Octagonal HDG 3mm Sheet Steel Poles". The pole shall be provided with Elmex Connector/SP MCB control for "loop in loop out" of the cable along with cable entry hole and internal wiring from the Elmex Connector/4 nos. SP MCB to the lamp control gear & lamp with 2Rx2.5Sqmm+1Rx1.5Sqmm Cu.wires and all other accessories complete as required. The pole shall confirm S355JO for poles HT steel grade & IS : 875 for wind velocity, base plate shall confirm IS : 226/IS : 2062, EN.8 grade for foundation bolts & amended upto date. The rate shall be inclusive of base plate, foundation bolts, spike earthing, painting, elmex connector & necessary foundation civil works etc. complete in all respect. 7 METERS HIGH OCTAGONAL POLE WITH 220X220X12MM BASEPLATE & 1 METER STANDARD FOUR ARMS BRACKET.
5
-
-
... More
STREET LIGHT FIXTURE
-
-
-
... More
Supply & Fixing of the "Outdoor Street Light Luminaire" with lamp, ignitor, controlgear, hinged front frame with glass cover etc. complete. The installation shall confirm IS : 732.1989 & amended upto date. The rate shall be inclusive of fixing & mounting accessories. 1X90W LED street light luminaires. (PHILIPS BRP333 LED110 CW R5C FG PSU S1 SPD OR APPROVED EQUIVALENT)
20
-
-
... More
INDOOR LIGHT FIXTURE
-
-
-
... More
Supply, installation, testing and commissioning of light fixture complete with all fittings and accessories, as required. Erection rate shall include necessary GI chain and supporting suspending hardware for fixing the light fittings. Recessed mounted light fixture (Philips Cat No. RC380B LED36S-6500 G6 L60W60 PSU OD or similar approved equivalent)
16
-
-
... More
SUB MAINS/CIRCUIT MAINS
-
-
-
... More
Supplying & drawing of wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire in 20mm size PVC rigid/flexible conduit (as per direction by EIC) 'FRLS' including necessary Fittings and neccessary connections as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
150
-
-
... More
EMPTY CONDUITS
-
-
-
... More
Supply and fixing of FRLS PVC (ISI marked) conduit (rigid/flexible) of various dia, exposed or concealed with all accessories like tees, bends, glands etc. JBs (PVC) as required and fish wire etc for wiring purpose complete and mending good damages to building works. 20 mm dia (2 mm thick)
150
-
-
... More
MCB ENCLOSURE
-
-
-
... More
SITC of 6-32 Amps DP MCB (C-Curve) with metal enclosure (outdoor type-IP65) (concealed/surface) mending good the damages to original finish including painting, connection & provision for earthing attachement.
4
-
-
... More
HI-WALL SPLIT AC
-
-
-
... More
Supply, Installation, Testing & Commissioning of Hi-wall Split 1st charge R 32 gas BEE 3 STAR RATED non-inverter type air-cooled split Air-conditioner with cordless remote, hermetic/semi hermetic rotary type compressor having with copper coil of IDU & ODU, 3 Mtrs. Copper pipe with Armaflex insulation, Electrical control cabling and 25 mm hard drawn UPVC piping with Armaflex insulation for sweat water drain complete as per direction of Engineer-in-charge. Extra copper pipe line (Suction & Liquid), Cable beyond 3 mtr. will be paid extra as per measurement. IDU shall be installed in porta cabins. 2.0 tr - 3 star
4
-
-
... More
Supply & laying, dressing, clamping, testing and commissioning of 1.1 KV grade, stranded copper conductor, PVC insulated, extruded PVC inner sheathed, Galvanized wire/strip armoured and PVC outer sheathed LT control cable conforming to IS 1554 (Part-1) and of following size between indoor units and outdoor units. 3C X 2.5 mm
60
-
-
... More
Supplying and installation of Power Coated AC Bracket for mounting Outdoor Unit.
4
-
-
... More
FIRST AID FIRE EXTINGUISHER - ABC TYPE
-
-
-
... More
Supply and Fixing of "ABC Powder Type Fire Extinguishers" shall confirm IS : 15683 & IS : 14609 with initial fill & all mounting accessories etc. complete. 2KGS CAPACITY.
8
-
-
Evaluation Notes How It Works ?