Water Resources Development Directorate Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Sep 2024
Closing Date30 Sep 2024
Tender Amount₹ 82,31,029 
Notes
Download

Costs

Summary

Revitalization And Energisation Of Kishorigaunge Monmohanpur-i Govt Owned And Operated Major Rli Scheme In Purbasthali-i Block Under Kalna (am) Sub-divin Under Core Sector (23-24) (sarasari Mukhyamantri) Programme Under E E (am) Burdwan (am) Division

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments

2700

791100

293

... More
140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II) As per IS 4985:2000 with latest amendments

36

17640

490

... More
200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

5

7410

1482

... More
140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

10

7120

712

... More
315 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

2

9188

4594

... More
200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

8

10608

1326

... More
160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

25

16750

670

... More
160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

25

8200

328

... More
200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

15

14910

994

... More
200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

5

8880

1776

... More
140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

37

23939

647

... More
200 mm dia P.V.C. End Cap(Cl-III) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-III (0.60 MPA)

2

1510

755

... More
140 mm dia P.V.C. End Cap(Cl-III) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-III (0.60 MPA)

4

1320

330

... More
315 mm dia P.V.C.Extra Coupler (Class-II) IS 10124:2009 with latest amendments and shall be duly marked with ISI certification Mark and shall be of Class-II (0.4MPA)

8

9488

1186

... More
200 X 160 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

2

1514

757

... More
Extra Solvent Cement as per I.S. 14182-1994 with latest amendments

10

4250

425

... More
M.S. ITEMS . . M.S. Quadrupped Set for Major RLI Scheme, All material ISI marked .

1

875000

875000

... More
150 mm dia 90º G.I Bend (both end flanged), long bend ISI marked-IS-1239/II, Galv- IS 4736

12

98100

8175

... More
150 mm dia 90º G.I Bend (both end flanged) long bend With priming arrangement, ISI marked-IS-1239/II, Galv- IS 4736

2

16786

8393

... More
Supply & Delivery of 150 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736 (4.8mm)

150

570000

3800

... More
VALVES AND OTHER ACCESSORIES. . 150 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846

11

109450

9950

... More
150 mm dia (type-C) Alfa Alfa Valve as per IS 210. IS 210/2009 (As per appvd. existing drawing)

25

110875

4435

... More
OTHER MATERIALS . . 150 mm dia P.V.C.Flexible Hose pipe, ISI marked - IS 15625

80

120240

1503

... More
ELECTRICAL ACCESSORIES 20 H.P. Electro Motor Pump set having capacity of 200 m³/hr discharge at 18 meter total head. The Motor shall be designed for operation at 415 V (+10%), 3 Phase, 50 Cycles per sec. (± 5%), A.C. Supply 1500 r.p.m. The Motor shall be TEFC, ISI marked with latest amendments thereof. The Pump shall be horizontal, single stage, split casing, conforming to ISI specification as per IS: 6595/12615 with latest amendments thereof. Pump should be directly coupled with Motor and mounted on a common fabricated M.S. base frame. IS 12615 & IS 6595 (Both having ISI Marked).

2

353800

176900

... More
200A Heavy duty rewireable Switch Fuse Units with fuse base and carrier, shall comply with and be tested by CPRI/ERDA/BIS lab tested as per latest IS: 10027-2000 and IS/IEC 60947-3

1

23217

23217

... More
63A Heavy duty rewireable Switch Fuse Units with fuse base and carrier, shall comply with and be tested as per latest IS: 10027-2000 and IS/IEC 60947-3, marked with standard ISI certification mark

2

16836

8418

... More
Automatic Star Delta motor controllers shall be suitable for operation of submersible electromotor pumps as well as motors for surface lift centrifugal agricultural pump operating at 415V(+%6 to -10%) and 5OHz(±3%) .The equipment shall comply with IS-60947/2000(Part-4, Sec-1)and its latest amendments. Starter shall comprise of overload protective device, main and auxiliary contacts, Single phasing preventer, timer and on/off controls .It shall be of utilization categories suitable for the particular application as shownin Table I of IS/IEC 60947-4-1, for electrical motor circuits unless otherwise specified and display of voltage & current as well as ON-OFF-TRIP position.

2

49400

24700

... More
415 Volt, 200Amps Busbar Chamber, IS 60947200 Amps, 500Volts bus bar Unit conforming to latest IS 8623:1993 & IS/IEC: 60947, with detachable front cover and undrilled detachable/integrated end plates with 2nos inlet holes of 1.5" size and 4 way/6way outlets, suitable for mounting on wall and designed for uninterrupted duties. The enclosure should be of adequate size to provide minimum clearance as mentioned in technical specification to accommodate 4 nos copper bar with at least 6 nos tap off points of 6mm dia at 30mm apart supplied with requisite brass / S.S nuts & bolts equivalent to bore size with spring / Belleville washers.including arrangement of double earthling by 10 SWG GI wires .

1

9697

9697

... More
Field Level Materials: Supply & Transportation of 150 mm dia MS Heavy Duty Hose Clamp fitted with bolts & nuts (2 sets) 2.0 mm thick, 45 mm width.

10

1380

138

... More
Supply & Transportation of 150 mm dia C.I. Foot valve, flanged end & swing type as per IS 4038/1986(Table-17) with latest amendment .The disc face will be made of leather and strainer made of C.I.The Valves shall be tested for (closed end test) against Hydrostatic test requirement.

2

10000

5000

... More
Supply & Transportation of 150 mm dia Foot Valve Leather Washer (Table-17) best quality brand (Imperial/Techno/Burhani).

2

680

340

... More
Supply & Transportation of 150 mm dia C.I. Tail Piece with flange adopter (Drilled Holes Confirming to Table-17,IS 6392),one side grooved overall length (175+/-15) mm and other end flanged (22 mm flange thk) with 7 nos. grooves.

4

7084

1771

... More
Foundation Bolt for Electro-Motor Pump set foundation and manufactured from 20 mm nominal diameter MS Rod as per IS:2062/1992. Total length of the Bolt is 375 +10 mm having welded head 80 +10 mm in length and 20 mm in nominal diameter nut and 2 nos. washer, The average weight of such bolt to be 1.5 kg. per bolt with tolerance in weight of each bolt @ +10%. Approx 8 nos.

8

1784

223

... More
Foundation Bolt for Distribution Chambers (Quadruped Sets) and manufactured from 20 mm nominal diameter MS Rod as per IS:2062/1992. Total length of the Bolt is 375 +10 mm having welded head 80 +10 mm in length and 20 mm in nominal diameter nut and 2 nos. washer, The average weight of such bolt to be 1.1 kg. per bolt with tolerance in weight of each bolt @ +10%. Approx 44 nos.

48

10704

223

... More
Supply and transport of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS 638/79 with ISI Mark with latest amendmends suitable for raised surface of MS flange as per IS 6392/71 (Table 5, 11 & 17).

-

-

-

... More
300 mm dia Rubber Insertion (Table No.11)

2

578

289

... More
300 mm dia Rubber Insertion (Table No.5)

4

1156

289

... More
200 mm dia Rubber Insertion (Table No.11)

6

1056

176

... More
200 mm dia Rubber Insertion (Table No.5)

12

2112

176

... More
150 mm dia EPDM Gasket/Insertion (Table No.17)

88

14608

166

... More
150 mm dia EPDM Gasket/Insertion (Table No.5)

14

2324

166

... More
80 mm dia Rubber Insertion (Table No.17)

2

190

95

... More
Supply & Transportation of 500 mm dia (Table-5) Compressed Asbestos Fibre Jointing for Quadruped set(for raised surface of flange as per IS:6392).

6

7308

1218

... More
Supply & Transportation of M.S. Hexagonal Head Nuts and Bolts conforming to IS 1363(Part-I)/1992 of product grade C with latest amendmends for Bolts & IS 1363(Part-3)/1992 of product Grade-C with latest amendments for Nuts properties /Class for Bolt-4.6 & for Nut-4.5.Finish: Galvanized. ISI marked.

-

-

-

... More
a) M 16 mm X 65 mm. Approx 56 nos.

10

2110

211

... More
b) M 16 mm X 70 mm. Approx 96 nos.

18

3798

211

... More
c) M 16 mm X 80 mm. Approx 56 nos.

12

2532

211

... More
d) M 16 mm x 50 mm(15 kg). Approx 100 nos.

15

3165

211

... More
e) M 20 mm X 80 mm. Approx 480 nos.

160

33760

211

... More
f) M 20 mm X 100 mm. Approx 152 nos.

60

12660

211

... More
Laying of WTA: Earth work in excavation of field trenches as per designed section & alignment for laying of pipe lines (PVC, RCC, ACP etc) upto a depth of 1500 mm in all sorts of soils including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom as required complete. [Vide Chapter no.6.2.10, item no. 1 of WRDD Schedule ]

2900

287129

99.01

... More
Earth work in filling in trenches after laying of pipe lines (PVC, RCC, ACP etc) or plinth with good earth, in layers not exceeding 225 mm. including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work).[Vide Chapter no.6.2.10, item no. 2 of WRDD Schedule ]

2765

182517

66.01

... More
Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee, Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by deptt.) all complete as per direction of Engineer-In- charge. [Vide Chapter no.6.2.20, item no. 1(A) of WRDD Schedule]

-

-

-

... More
i) 315 mm.OD.

498

5637

11.32

... More
ii)200 mm OD

1500

16260

10.84

... More
ii) 140 mm. OD.

2700

27378

10.14

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. [Vide Page no.1, item no. 2(a) of PWD Schedule] (a) Depth of excavation not exceeding 1,500 mm.

0.37

4424

11927

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) [Vide Page no.1, item no. 3(a) of PWD Schedule] (a) With earth obtained from excavation of foundation.

5.94

460

77.54

... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. [Vide Page no.14, item no. 1 of PWD Schedule 3rd CORRIGENDA & ADDENDA]

126.53

40995

324

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water, ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity)

0.1

5278

52107

... More
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. normal size) excluding shuttering and reinforcement, if any, in ground floor. as per relevent IS Code. a) Pakur Variety

6.4

33605

5250.86

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. a) Pakur Variety

11.08

64838

5851.86

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation [Vide Page no.43, item no. 36(A) of PWD Schedule]

48.45

9932

205

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel I.SAIL/ TATA/RINL

0.73

39952

54729.23

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation & plinth

23.75

114285

4812

... More
125 mm. thick brickwork with 1st class bricks in cement mortar (1 : 4) in ground floor.

31

20584

664

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]. Vide Page 49 of 96 Item no-1 of PWD Schedule 3rd CORRIGENDA & ADDENDA (i) With 1:6 cement mortar (a) 20mm.thick plaster (3 rd corrigenda,PWD, P-50,Item - 1(i) b ]

130.13

20170

155

... More
(b) 15 mm thick plaster (3 rd corrigenda,PWD, P-50,Item - 1(i) c ]

175.75

23902

136

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.

305.88

10399

34

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i)(a) 150 mm. dia. ERW pipe.

150

20226

134.84

... More
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site).

1

29920

29920.75

... More
Labour charges for fitting, fixing 150 mm. Dia. Alfa-AIfa valve with 160mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.

25

2805

112.21

... More
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made of 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include materials and labour complete as per drawing and direction of EIC.

1

3677

3677.51

... More
Supplying 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.

1

942

942.95

... More
Fitting and fixing of M.S. / G.I. / C.l. accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. iv) 150 mm. dia. C.I. sluice valve. [Vide Page No 19, item no. 7 of WRDD Schedule ]

11

601

54.69

... More
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entire pipe line net work for at least 4 (four) hours by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge. i) For Major R.L.I.

1

4987

4987.26

... More
For Water transmission Arrangement of RLI/Tube well 4% extra over the schedule rates,save & except fo rearth work in excavation & filling works,will be allowed for extra carriage by cart/boat/head load besides initial transport by truck etc.Except Item no. (1,3,20,21 & 22)[Vide Chapter no.2, item no. 11 of WRDD Schedule ] item no. except 2.01,2.02,2.04,2.05,2.22

1

19655

19655.11

... More
Add 18% GST on all Items from 2.01 to 2.23

1

178302

178302.27

... More
Add 1% CESS on all Items from 2.01 to 2.24

1

11688

11688.7

... More
CONSTRUCTION OF NEW STEEL BARGE Patch/Doubling works complete with M.S. plate including welding, gas cutting, fitting, fixing complete.

-

-

-

... More
(a) Cost of 5 mm M.S. plate including wastage due to cutting, including labour charges for straightening fitting, fixing in position. WRDD (Chapter 7.0, Item. 4 (a)).

80

280240

3503

... More
(b) Gas cutting to required size of 8 mm thick M.S. plate, M.S. Channel, M.S. Angle etc. including labour charges, hire charges for all tools and plants. WRDD (Chapter 7.0, Item. 4 (b)).

200

46800

234

... More
(c) Electric welding charges of 8 mm M.S. plate M.S. channels etc. and other member of the barge including hiring charges of all tools and plants. WRDD (Chapter 7.0, Item. 4 (c)).

800

437600

547

... More
Supply, fitting, fixing complete with fastener.Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:- a) With 0.5 mm thick sheet PWD (Building) page -83 Item no-14.

30

26880

896

... More
Supply, fitting, fixing complete with fastener. Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping). (A) 300 mm lapping each way (b) With 0.91 mm sheet PWD (Building) page -84 Item no-18.

7

3325

475

... More
Supplying, fitting, fixing in position netting with PVC Coated Crinkle mesh of approved colour with wooden or steel or concrete frame work including cost of galvanised bolts, nuts, screws, nails, spacers, shape welding etc complete but excluding the cost of supporting frame works, battens etc.(e) 75 mm. x 25 mm. x 8 g.PWD (Building) page 222 - Item no-12.

18

9414

523

... More
Supplying 1.5 mm (16 SWG) M.S. sheet fitted and fixed on one or both faces of M.S.bar etc. with point welding not more than 150 mm apart complete in all respect and including cost of labour and materials as per direction of Engineer-in-Charge.WRDD (Chapter 7.0, Item. 7).

16

23936

1496

... More
Supplying, fitting & fixing of M.S. angle (Size: 50 mm x 50 mm x 6 mm) including gas cutting etc.WRDD (Chapter 7.0, Item. 8 (b)).

180

61740

343

... More
Supplying, fitting & fixing of M.S. flat bar 40 mm x 6 mm for straightening the B.RC. net including gas cutting etc.WRDD (Chapter 7.0, Item. 9).

120

21120

176

... More
Supplying, fitting & fixing bolts with nuts & washers (i) 10 to 16 mm dia. a. Length upto 75 mm.WRDD (Chapter 7.0, Item. 10).

15

2640

176

... More
a) Supplying, fitting and fixing of M.S. channel (Size 75 mm x 40 mm x 6 mm) for base of manhole cover including gas cutting.WRDD (Chapter 7.0, Item. 11.0 (a)).

8

3592

449

... More
(b) Drilling charges 12 mm dia. hole for manhole cover plate and M.S. Channel base. WRDD (Chapter 7.0, Item. 11.0 (b)).

750

8250

11

... More
(c) Supplying, fitting and fixing of (1/16)" thickness rubber insertion sheet with 12 nos. drilling hole for watertight arrangement of manhole cover. WRDD (Chapter 11.0, Item. 4 (c)).

5

335

67

... More
Chipping, scraping wire brushing and cleaning of the painted surface for keel, hull, frame, superstructure deck, fender both inside and outside as per direction of the Engineer-in-Charge. (b) Small hatch (total area 255 m2 approx.) WRDD (Chapter 7.0, Item. 12.0 (b)).

1

1808

1808

... More
(a) Cost of Doors (6'-0'' x 3'-0'') by point welding with B.R.C. net (75mm x 25mm x 10 SWG), 50 mm x 6 mm M.S. flat bar, 6'' hings 4 pcs. 10'' hasp bolts - 2 nos. Etc . Complete as per direction of the Engineer in-charge.WRDD (Chapter 7.0, Item. 13.0 (a)).

2

6110

3055

... More
Supply, fitting, fixing complete of 1" dia MS Rod for Plate welding of MS Plates of the Barge. WRDD (Chapter 7.0, Item. 13.0 (b)).

50

13600

272

... More
PAINTING (a) Painting with Acrylic Polyurethane paint Two coat of approved make and brand (Minimum Dry Film Thickness [DFT] 100 micron) at all locations prepared and applied as per manufacturer's specifications. [On steel surface].WRDD (Chapter 7.0, Item. 14.0 (e)).

120

13800

115

... More
(b) Painting One Coat on Steel work with Zinc Rn EPOXY PRIMER of approved make and brand (Minimum Dry Film Thickness [DFT] 50 micron) at all locations prepared and applied as per manufacturer's specifications including smoothening surfaces by sand papering, power tools etc. [On steel surface].WRDD (Chapter 7.0, Item. 14.0 (d)).

225

8775

39

... More
(c) Painting with Coal Tar Epoxy paint (min coating thickness 200 micron) of approved make and brand at all locations prepared and applied as per manufacturers specifications including preparation of surface, etc.complete. on steel surface - 2 coats (with any shade except white) as per direction of the Engineer-in-Charge.WRDD (Chapter 7.0, Item. 14.0 (f)).

105

13755

131

... More
Transportation charges for carrying of all the materials, working devices etc. upto the scheme and back. WRDD (Chapter 7.0, Item. 15.0).

1

8147

8147

... More
Add GST @18% on all items from Sl No 2.26 to 2.40

1

178536

178536.06

... More
Add CESS @1% on all items from Sl No 2.26 to 2.41

1

11704

11704.03

... More
INTERNAL WIRING Fixing only of 200 A, 415 V sheet steel TPN main switch on Angle iron Frame on wall (PWD elec. Sh. 2017, Page-C-1,item-2)

1

280

280

... More
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. [200/250A] (PWD elec. Sh. 2017, Page-D-5, item-5)

1

567

567

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 3½ core upto 70 sqmm. (PWD elec. Sh. 2017, Page-F-4, item-7d)

1

212

212

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels) make, tapes, anticorrosive paste & jointing materials : For 3½ core 70 sqmm cable. (PWD elec. Sh. 2017, Page-F-5, item-8b, xvii)

1

263

263

... More
Fixing only of 4 Bars 200 A, 415 V M.S. sheet metal busbar chamber on angle iron frame on wall . (PWD elec. Sh. 2017 Page-C-1, item-6)

1

486

486

... More
Fixing only of 63 A, 415 V sheet steel TP main switch on Angle iron Frame on wall (PWD elec. Sh. 2017, Page-C-1,item-1)

2

430

215

... More
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables. (iii) Star-Delta / Auto-Transformer Starter (Above 15 HP upto 25 HP)(WRDD schedule-2018 , Chapter-9.00/ Item No.12 )

2

480

240.45

... More
Meter loop connection with 1.1 K.V. Gr. 3½ core / 4 core 50 Sqmm P.V.C./ XLPE insulated & sheathed and armoured Aluminium Cable from Meter to incomming TPN Main Switch / Terminal. (Brand: Polycab/Havells/Finolex) (WRDD schedule-2018 , Item no.-9.00/13 ) v) For Major RLI

30

14596

486.56

... More
Supplying and Drawing with 1.1KV, PVC flexible 'FR'cables copper conductor conforming to IS694 insuitable size with fitting and fixing on wall/Kiosk Box including making necessary connection to thepre fixed devices with all necessary accessories likesaddle ,screw,clips,gland,socket etc. conforming to IEE regulation and as per direction of EIC.(Brand: Gloster/Havells/Finolex) (WRDD schedule-2018 , Chapter No.9, Item no.-14 ) a) For Major RLI

-

-

-

... More
(i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to Bus-bar]

2

3123

1561.53

... More
(ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]

6

4763

793.96

... More
(iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor]

12

11123

926.92

... More
Suppling & fixing of EI danger Board 4"x 6" in two distinguishing position . As per IEE regulation. ( PWD Elect. Sh 2017 page D-13, Item -21 )

2

110

55

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. ( PWD Elect. Sh 2017 page G-1, Item -1 ) (b) For Morrum Soil

3

858

286

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe ( PWD Elect. Sh 2017 page G-2, Item -3(a) )

2

1830

915

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode. ( PWD Elect. Sh 2017 page G-2, Item -3(b) )

2

1062

531

... More
Earthing with 50 mm dia Galvanized iron pipe 3.64 mm thick X 3.04 mtr. long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm dia X 80 mm long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. below the ground level. By TATA-Medium G.I. Pipe (PWD elec. Sh.2017 Page-G-1,item-2(a) )

2

3048

1524

... More
Supplying and fixing earth bar of galvanized (hot dip) M.S. Flat 40 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required for tapping. (PWD elec. Sh. 2017 Page-G-2, item-4b)

0.6

116

194

... More
Connecting the equipments to earth busbar including supplying and fixing G.I. (hot dip) Wire on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages. By Solid 4 S.W.G. GI Wire (PWD elec. Sh. 2017 Page-G-2, item-5(a))

60

1080

18

... More
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger (WRDD schedule-2018 , Chapter No.9, Item no.-15)

1

165

165.02

... More
Placing and positioning the Centrifugal pump motor set on the pump base/pump house floor, alligning properly with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages- complete as per direction of Engineer-in-Charge. (WRDD Schedule-2018, Item no. 3.00/1) 20 HP capacity

2

1289

644.98

... More
Considering Extra Rates @3% for Bardhaman District & applicable for PWD Schedule item only

10342.4

310

0.03

... More
Add GST @18% on all items from Sl No 2.43 to 2.61

1

8315

8315.13

... More
Add Labour welfare cess@1% from Sl No 2.43 to 2.62

1

545

545.1

... More
Energisation : WBSEDCL Supply of materials ,survey erection,testing, commissioning of a new 63 KVA S/stn ,drawl of HTOH line with allied works for electrification for Kishorigaunge Manmohanpur-I Govt. Owned and Operated Major RLI Scheme in Purbasthali-I Block under Kalna(A-M) Sub Division under Burdwan(Agri-Mech) Division.

-

-

-

... More
MATERIAL COST . PCC Pole 9 Mtr.

14

142775

10198.28

... More
PCC Pole 8 Mtr.

3

16090

5363.44

... More
M,S. Channel 100x50x6 mm. ( 10.2 Kg )

0.05

5380

109813.95

... More
M.S. Channel 75x40x6 mm. (7.6 Kg )

0.19

20908

110043.09

... More
M.S. Angle 65x65x6 mm, (6.4 Kg )

0.12

13257

108667.24

... More
M.S. Angle 50x50x6 mm. (4.8 Kg )

0.01

548

109603.22

... More
MS. Flat 65x6 mm. ( 3.3 Kg )

0.16

18564

117493.74

... More
"V" Bracket 11 KV PCC Pole 9 mtr

8

10513

1314.19

... More
Top Adopter 11 KV PCC Pole 9 mtr

8

3824

478.12

... More
Stay Set H.T. 1830x20 mm.

10

7958

795.83

... More
Stay Wire 7/3.15 mm

0.06

8538

142310.93

... More
Guy Insulator H.T.

10

522

52.24

... More
Stay Set L.T. 1680x16 mm.

2

1103

551.57

... More
Stay Wire 7/2.50 mm

0.01

1070

107035.14

... More
Guy Insulator L.T.

2

36

18.37

... More
G.I. Earth spike 1622x20 mm.

22

8095

367.98

... More
G.I. wire 5 mm. (0.150 Kg )

0.11

15055

136865.98

... More
Pin insulator 11 KV Polymer

33

8045

243.79

... More
Disc Insulator 11 KV Polymer

12

2197

183.15

... More
Hard Ware fittings 50/30 Sq.mm.

12

3933

327.83

... More
T.P.G.O. Isolator 200 Amp.

1

10384

10384.98

... More
Lighting Arrestor 12 KV

3

1572

524.23

... More
Transformel- 63 KVA, 11/0.4KV

1

197568

197568.41

... More
Upper Clamp LT BKT 50X6 Flat 8 Mtr

6

652

108.78

... More
LT Dist. Box 3 Ph Con. WH ST Strap & Buckle-ABC

1

1489

1489.9

... More
LT AB Cable 1.1 KV 3cx70+1cx16+1cx50 sq mm

0.05

15777

315558.99

... More
Anchor Clamp suitable for 35 sq mm Messenger Conductor for HT AB Cable

2

898

449.46

... More
Eye hook for Ancho & Suspn Clamp (LT)

3

331

110.64

... More
Suspension Clamp suitable for 180 sq mm Messenger Conductor for HT AB Cable

1

416

416.03

... More
PVC Cable 4 Core 50 Sq.mm.

0.02

4964

248238.29

... More
ACSR 50 Sq.mm. ( 205 Kg) / KM

1.3

80728

62290.12

... More
G.I. Turn Buckle

2

477

238.7

... More
LT. Kiosk

1

10456

10456.61

... More
LABOUR COST . Survey of H.T.O.H. Line

0.41

1132

2761

... More
Survey of L.T.O.H. Line

0.05

85

1714

... More
Erection of D.P. by PCC Pole 9 Mtr. With fittings with painting

1

8289

8289

... More
Erection of PCC Pole 9 Mtr. With fittings

8

20960

2620

... More
Erection of PCC Pole 8 Mtr.

3

4503

1501

... More
Erection of Sub/Stn. Structure by PCC Pole 9 Mtr. With all fittings

1

13169

13169

... More
Stringing Sagging of ACSR 50 Sq.mm. 3 Cod.

0.41

3398

8289

... More
Erection of D.P. by PCC Pole 9 Mtr. With fittings with painting

1

8922

8922

... More
Extension of PCC Pole 9 Mtr.

2

3412

1706

... More
Erection of 63 KVA Transformer

1

2711

2711

... More
Re-Fixing of Pin insulator

3

159

53

... More
Re-Fixing of Dis Insulator

6

318

53

... More
Re-sagging ACSR 50 sqmm 3-w

0.25

427

1708

... More
Fixing of Pin Insulator 11 KV with pin

33

2079

63

... More
Fixing of Disc Insulator 11 KV

12

780

65

... More
Erection of Stay Set HT 1830 x 20 mm

10

6410

641

... More
Erection of Stay Set LT 1630 x 10 mm

2

1110

555

... More
Flat Earthing for DTR Neutral Point

1

3816

3816

... More
Earthing Complete

22

6886

313

... More
Fixing of T.P.G.O. Isolator on S/S

1

1193

1193

... More
Fixing of L.T. Kiosk & M.S. with C.C (DC)

1

3012

3012

... More
Fixing of Lighting Arrestor

1

339

339

... More
Erection of Distribution Box

1

507

507

... More
Erection of Anchor Clamp

2

308

154

... More
Erection of Suspension Clamp

1

154

154

... More
Stringing Sagging of 1.1 KV 3cx70+1cx16+1cx50 sq mm

0.05

2500

50000

... More
GIS Survey charges for Electrical Network

13

403

31

... More
Cess 1% of Total (From Sl No 3.01 to 3.60)

1

7822

7822.36

... More
GST @18% for Labour & Supervision

1

19202

19202.67



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.