Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date3 Oct 2024
Closing Soon27 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 3,29,226Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Construction Of 9 Storied Court Building At Within The District Judges Court Compound At Bankura ----- Sitc Of Passenger Lift.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_759994_1Tender No
WBPWD/SE/SWEC/NIQ41/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system.
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor.
Car operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.
Landing operating panel: A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.
Fire Rated Door : 2 Hours
-
-
-
ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of power failure / single phasing/others. Overload Protection: Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication.
Emergency lighting in car: Battery operated emergency lighting in the lift car.
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room.
Emergency Alarm: Battery operated alarm bell system in lift car and control room.
Fireman switch: Fireman switch at main landing terminal.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.
Main rope - Belt Type (Flat Coated steel belt with V groove / Sreel rope)
-
-
-
Communication & Monitoring the Lift: Lift controller/ Panel shall be Ethernet/Modbus ready with necessary converter, DC Power supply module etc. if required, and there shuld be single Ethernet/Modbus output from the Controller/panel and the same should be connected to BMS (Building Management System) and the controller/ panel should have also required for monitoring of real time data with date & time, maintenance-call back record, Mantrap notice, call records, location of car, Lift room temperature etc. should be noticed & display to in any desktop & mobile though wireless system.
-
-
-
Other works: Necessary cutting of wall/floor for fixing the Fire Alarm switch, all Button switch and also making provision to entry of rope, electric wire etc. as required to complete the job.
-
-
-
DIMENSION OF SHAFT & POWER SUPPLY
Available Shaft Dimension: 1950(W) mm X 2025(D)mm
(Bidder should visit the site)
Pit Depth : 1600 mm (Bidder should visit the site)
Overhead : 4500 mm (Bidder should visit the site)
-
-
-
Electric power supply: AC 415 Volt 3phase, 50 Hz, terminated in machine room as per IS
-
-
-
SITC of Automatic Lift ( as per manufacturer design & as per detailed specification below conforming to IS ) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd.
1
-
-
Make : OTIS / KONE/SCHINDLER
Type: passenger Lift .
Load : 16 Passenger / 1088 Kg Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)
Machine:- Energy efficient machine, Gearless, Without Machine Room.
Position of Machine Room: Directly above the lift
Speed: 1 Mtrs./ Sec
Floor served: B+G+7
Landing: 9, all on same side
Total Rise : 32 Mtr (Approx) (Bidder should visit the site)
-
-
-
Operation: Microprocessor based implex full collective with or without attendant.
Signals: Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator.
Leveling accuracy: ±5 mm(Micro levelling arrangement.
-
-
-
CAR
Car inside : 1000 mm ( W ) x 2400 mm ( D ) x 2300 mm (H) or As per manufacturer's standard conforming to IS.
Car Entrance : Clear Opening 900 mm (W) x 2000 mm/ 2100mm (H ) protected with car door
Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail.
Car Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and Fan
Car Ventilation: Pressure fan with anodised aluminium grill.
Car Flooring : Decorative granite flooring (As per direcion of EIC and according to this Department's Order).
-
-
-
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor
Car operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.
Landing operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.
Fire Rated Door : 2 Hours
-
-
-
PROTECTIVE DEVICES & OTHER ACESSORIES
ARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.
Overload Protection: Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication
Emergency lighting in car: Battery operated emergency lighting in the lift car.
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room
Emergency Alarm: Battery operated alarm bell system in lift car and control room
Fireman switch: Fireman switch at main landing terminal.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.
Main rope - Belt Type (Flat Coated steel belt with V groove / Sreel rope)
-
-
-
Communication & Monitoring the Lift : Lift controller/ Panel shall be Ethernet/Modbus ready with necessary converter, DC Power supply module etc. if required, and there shuld be single Ethernet/Modbus output from the Controller/panel and the same should be connected to BMS (Building Management System) and the controller/ panel should have also required for monitoring of real time data with date & time, maintenance-call back record, Mantrap notice, call records, location of car, Lift room temperature etc. should be noticed & display to in any desktop & mobile though wireless system.
-
-
-
Other works: Necessary cutting of wall/floor for fixing the Fire Alarm switch, all Button switch and also making provision to entry of rope, electric wire etc. as required to complete the job.
-
-
-
DIMENSION OF SHAFT & POWER SUPPLY
"Available Shaft Dimension: 1925(W) mm X 3050(D) mm (Bidder should visit the site)"
Pit Depth : 1600 mm (Bidder should visit the site)
Overhead : 4500 mm (Bidder should visit the site)
-
-
-
Electric power supply: AC 415 Volt 3phase, 50 Hz, terminated in machine room as per IS
-
-
-
SITC of Automatic Lift ( as per manufacturer design & as per detailed specification below conforming to IS ) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd.
4
-
-
Make : OTIS / KONE/SCHINDLER
Type: Passenger Lift .
Load : 13 Passenger / 1088 Kg Control: Microprocessor based with AC variable voltage & variable frequency (VVVF)
Machine:- Energy efficient machine, Gearless, Without Machine Room
Position of Machine Room: Directly above the lift
Speed: 1 Mtrs./ Sec
Floor served: B+G+7
Landing: 9, all on same side
Total Rise : 32 Mtr (Approx) (Bidder should visit the site)
Operation: Microprocessor based implex full collective with or without attendant.
Signals: Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator.
Leveling accuracy: ±5 mm(Micro levelling arrangement)
-
-
-
CAR
Car inside : 1000 mm ( W ) x 2000 mm ( D ) x 2300 mm (H) or As per manufacturer's standard conforming to IS.
Car Entrance : Clear Opening 800 mm (W) x 2000 mm/ 2100mm (H ) protected with car door
Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail.
Car Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and Fan.
Car Ventilation: Pressure fan with anodised aluminium grill.
Car Flooring : Decorative granite flooring (As per direcion of EIC and according to this Department's Order).
-
-
-
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system.
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system.
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor.
Car operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.
Landing operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.
Fire Rated Door : 2 Hours.
-
-
-
PROTECTIVE DEVICES & OTHER ACESSORIES
ARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.
Overload Protection: Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication
Emergency lighting in car: Battery operated emergency lighting in the lift car.
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room
Emergency Alarm: Battery operated alarm bell system in lift car and control room
Fireman switch: Fireman switch at main landing terminal.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.
Main rope - Belt Type (Flat Coated steel belt with V groove / Sreel rope)
-
-
-
Communication & Monitoring the Lift : Lift controller/ Panel shall be Ethernet/Modbus ready with necessary converter, DC Power supply module etc. if required, and there shuld be single Ethernet/Modbus output from the Controller/panel and the same should be connected to BMS (Building Management System) and the controller/ panel should have also required for monitoring of real time data with date & time, maintenance-call back record, Mantrap notice, call records, location of car, Lift room temperature etc. should be noticed & display to in any desktop & mobile though wireless system.
-
-
-
Other works: Necessary cutting of wall/floor for fixing the Fire Alarm switch, all Button switch and also making provision to entry of rope, electric wire etc. as required to complete the job.
-
-
-
DIMENSION OF SHAFT & POWER SUPPLY
"Available Shaft Dimension: 2000(W) mm X 2700(D) mm (Bidder should visit the site)"
Pit Depth : 1600 mm (Bidder should visit the site)
Overhead : 4500 mm (Bidder should visit the site)
-
-
-
Electric power supply: AC 415 Volt 3phase, 50 Hz, terminated in machine room as per IS
-
-
-
Terms & Condition
i) The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
-
-
-
ii) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
-
-
-
iii) The rate quoted by the manufacturer should be inclusive of all taxes and duties and for providing 2 years DLP after completion of 1 year of initial commisioning.
-
-
-
iv) Rates should be quoted with minor civil works, wall cutting and mending good the damages to the original finish.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%