Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Oct 2024
Closing Date29 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 14,618Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwd/ee-ii/ckhed/ Enit-67/24-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_765485_1Tender No
WBPWD/EE-II/CKHED/ eNIT-67/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
a) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [Vide page no-E-9,item no-1(s)]
55
-
-
b)4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC[Vide page no-E-9)
35
-
-
c) 4 x 16 sqmm + 2 x 10 sqmm ECC) [Vide page no-E-9,item no-1(g1)]
12
-
-
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.[Vide page No F-5, Item No-9 (i)& (ii)]
-
-
-
a) 2x2.5 sqmm+1x 1.5 sqmm ECC [F-5,9(i)]
5
-
-
b)3x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC[Vide page no-E-9)
4
-
-
c) 4 x 16 sqmm + 2 x 10 sqmm ECC) [Vide page no-E-9,item no-1(g1)]
4
-
-
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Vide page No D-11, Item No-15] Incoming - 415V, 25/35KA, 100A, FPMCCB (1 -nos)[Vide page No D-8, Item No-10] Outgoing - 10KA, (C-characteristics) 63A, TPMCB - (6 -nos)[Vide page No D-6, Item No-7
-
-
-
6 way [Legrand/ L&T/ ABB]
1
-
-
Supply & fixing of 415 V Timer DB with steel sheet enclosure double door, phosphatised powder coated , neutral bar, Din Rail with IP-43 protection. i) 1 no. 32A TPN MCB ('C' Curve, 10 kA,), ii)1 no. 24 hours programmable Digital Time Switch. (Cat no:-67DDTO make:- L&T/ or Similar) iii) 3 no. 32A contactor,3-phase screw type motor starter. iv) 1 no. Auto Manual bypass Changeover Switch . v) Provision for earthing attachment including LED indication light for running condition and locking arrangement. Suitable DB size selection with internal wiring 6sqmm Copper wires along with Proper Connection with Cu.Socketting end to be fixed maintaining recommended clearance.as directed by EIC. (Make:- ABB/ L&T/Legrand)
2
-
-
Supply and Fixing 240V 3 nos 6A,1 no 20A Plugh Socket with separate 3 nos 6A 1No 20A Pino key type switch 1 No Indicator 1 no 6A MCB on shet metal switch bpard embeded in wall incl. supply and fixing 240X200X65 mm MS(SWG) switch board and bakelite perpex top cover of 3 mm thick by brass screws after making housing for switch by cutting bakelite/perpex cover and necy. connection as required.
6
-
-
Supply & Fixing 240 V, 20 A Piano key type Plug socket (Make:- Anchor) on sheet metal switch board incl. S & F 100x100x65mm MS(16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/ perspex cover and making necessary connections as required. [Vide page No-8, Item No17b ]
2
-
-
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision with 415V,63A four pole MCB,concealed in wall after cutting the wall & mending good the damages to original finish incl. painting,connection & provision for earthing. attachment(D6/7+D9/11)
2
-
-
Supplying & Fixing of PVC water proof type Loop box(Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass Stud/ terminal make- AC /DC. & 63A FP MCB (L&T) having hinged PVC top cover & 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement,one NL on porcelain insulator etc. on wall as per direction of EIC
2
-
-
Supply and Delivery of 1.1 KV grade following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab) as mentioned below as per choise of EIC.
-
-
-
4 Core 70 sqmm
55
-
-
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. [[Vide page No F-1, Item No-2(d)]
55
-
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. [[Vide page No F-4, Item No-7]
-
-
-
4 Core 70 sqmm
2
-
-
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. [Vide page No F-5, Item No-8(b)]
-
-
-
4 Core 70 sqmm
2
-
-
S & F of recessed mounted 2x2 LED luminaries down light LED fittings [make- Crompton Cat no LCTLRNE-36-FO-CDL or equivalent cat of Bajaj/Phillips] directly suspended from the ceiling with S & F of 2x2 LED luminearies frame incl. connecting the length of PVC insulated wire and mending good damages to original finish and painting as directed by EIC.
14
-
-
Supply Twin LED T/L fittings( Philips TMC 501 P 2xT-LED 22W P3242) incl. 2x MAS LED tube (PC body) 1200mm 18W865 T8 I --2100 lm.)(Corridor)
4
-
-
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 3x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. ][Vide page No C-2, Item No-17]
4
-
-
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 3x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [Vide page No C-2, Item No-16]
4
-
-
Supply of 5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr. with 2 Nos. twin rotary compressor, 2 nos. IDU of rated power supply-420V-3ph-50Hz. , 1no. ODU. Air-flow/per IDU:- 2000CFM. ( Make: Hitachi/O-general/ Mitsubishi-Electric)
2
-
-
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
-
-
-
a) Liquid Line (3/8" OD with 0.6 mm thick)
35
-
-
b) Suction Line (5/8" OD with 0.7mm thick)
35
-
-
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex)
-
-
-
a) Liquid Line (3/8" OD with 0.6 mm thick)
35
-
-
b) Suction Line (5/8" OD with 0.7mm thick)
35
-
-
Control copper Cabling from Condensing Unit to control panel (Make: KEI/polycab/ finolex).
-
-
-
a) 4 core 2.5 sq.mm communication cable
30
-
-
Erection & Commissioning Charges incl. refrigerant R-410A / R-22 for 4TR concealed type Split Air Conditioner
2
-
-
S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
-
-
-
a) 25 mm dia
25
-
-
Charges for scaffolding arrangement incl. lifting for outdoor & indoor units
2
-
-
Supply and fixing flexible canvass connection for concealed split air-conditioners.
4
-
-
charges for trap door of 1600 mm x 600 mm and 9 mm thickness made of aluminium channel & ply wood for IDU maintenance.
4
-
-
Supply and Fixing AL power Coated countintuous girll (Make-Premier)
3
-
-
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr.
Structural design should be approved by E.I.C.
2
-
-
Supplying, fitting & fixing in position suspended boxing for return air arrangement & indoor units of concealed split airconditioner with frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC.
25
-
-
Cutting iron windows and macking door there for passage for outdoor installation, fixing and provision for future maintenance purpose. Including charges of welding , masonary charges, labour charges and materials charges for sand ,cement , chipes etc.
1
-
-
Rate is inclusive all taxes and cess
-
-
-
Defect Libility Period 1 year
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements