Public Health Engineering Department Tender

View complete overview of WB PHED Tender

Public Health Engineering Department

Civil Works
View183 Views
Download69 Downloads

Opening Date

20 Aug 2021

Closing Date

20 Sep 2021

Tender Amount

₹ 1,13,41,296

Costs

Summary

Providing Functional Household Tap Connection (fhtc) In Connection With Jal Jeevan Mission Under Command Area Of Maslandapur Water S Scheme (zone-i)at Habra-i Block Within The Jurisdiction Of Habra Sub-division, Under Barasat Division, Phe Dte.(ph-i)

Description

Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    Unregistered TenderId
  • BidAward Id

    Unregistered BidAwardId
  • Tender No

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Tender Authority

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Purchaser Address

    Authority for unregistered User
  • Email

    Data for unregistered User
  • Website

    wwww.unregistereduser.com

BOQ Items

ItemQuantityUnitsRateAmount
... more
Providing FHTC from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline by installing 10mm NB gunmetal ferrule conforming to IS 2692:1989 wirh latest amendments on the said pipeline with supply, fitting & fixing of all other acsessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc. and supply & laying of 15mm NB PVC (schedul80)/20mm OD HDPE (PE100, PN16) pipe (average 15m length) with all necessary specials 1.0metre below the ground connecting the ferrule including cutting trenches in all sorts of soil and filling up trenches as per direction of the EIC and upto a point just inside the premises of the household or as directd by EIC, Supply and installation of a 15mm dia alloy iron bib cock (tested to 21kg/cm2) above 1.0mtr from ground an alloy stop cock of 15mm dia with brass spindle (tested to 21kg/cm2) to be fitted in a position as directed by EIC GI pipe of TATA make (medium duty) of 2 metre length with all necessary specials to continue from the end of the HDPE/PVC pipe and upto 1.0 m above ground within the premices of household. Note:- 1. PVC pipe shall of schedule 80(medium duty) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS:1239 (Part-I). 2. Rate is exclusive of supply and delivery of 10mm NB gunmetal ferrule. 3. Payment of supply & laying of 15mm NB PVC (schedule80)/20mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0metre below the ground will be made on actual measurment basis. The rate of this item is Rs. 117/- per metre.
2027Each-3044
... more
Collection of house hold details at prescribed format through mobile app/hard copy including geo-referance as directed by EIC and submission of the same to PHE Dte. in soft copy
2027Each-28
... more
Making village road (average 3m width) crossing by horizontal auger boring for accomodation of laying of average 3 (three) nos. 15mm GI pipes for FHTC or as per direction of Engineer-In-Charge.
1115Mtr.-188
... more
Provision for extra supply and laying of 15 mm NB PVC (schedule 80) / 20 mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0 meter below the ground including cutting trenches in all sorts of soil and filling up trenches as per direction of the E.I.C., beyond 15 m. length as consider in item no.1
6081M-117
... more
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. (a) upto 150 mm. Thick
41Cum-939
... more
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (c) Paku Variety
41Cum-5539.98
... more
Supplying, laying, fiting, fixing and jointing of UPVC pipes onforming to IS:4985-2000 with latest revision and amendments, if any, with ecessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing elephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as pplicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good uality/approved brand solvent cement (as per IS:14182-1994 cluding cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as equired at site by adopting suitable method so as to facilate the aintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with istribution pipes etc. all complete as per drawing direction and atisfaction of the E.I.C.
---
... more
N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to beproduced before laying of pipe line. ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list.iii)No part payment at any stage on account of supply of materials shall be entertained. iv)Payment will be made on actual consumption of materials. v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate ofentire item. viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill. (A) Pressure Rating : Class - III Laying of pipe line including cost of pipe & fittings/specials butexcluding cost of valves.
---
... more
75 mm dia OD
4950mtr.-232
... more
90 mm dia OD
3600mtr.-311
... more
110 mm dia OD
500mtr.-427
... more
Labour for boring (horizontal) through any kind of soil for road crossing LDS including hire charges & labour for supply of subtable dia crossing upto full witth road with necessary tools, trackles. including. Necessary arrangement for boring & pushing reqd. inclu. fixing, jointiong, pumping of accumulated water, lighting arrangement, sealing of two casing ends by B/W (1 : 4) etc. as per direction of EIC. (B/W to be give seperatly).
---
... more
100 mm dia
36Mtr-369.62
... more
150 mm dia
30Mtr-553.39
... more
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source).
---
... more
75 mm dia OD
4950mtr.-3.15
... more
90 mm dia OD
3600mtr.-3.6
... more
110 mm dia OD
500mtr.-3.78
... more
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).
---
... more
75 mm dia OD
4950mtr.-0.69
... more
90 mm dia OD
3600mtr.-0.88
... more
110 mm dia OD
500mtr.-1.08
... more
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over 150mm. thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]PHEDSOR 2019, OH-14 & it-57
---
... more
80 mm to150 mm dia pipe.
5Each-12649
... more
Add : GST (@ 12%)
1No-1203107.78
... more
Add : CESS (@ 1%)
1No-112290.06
Total Amount ₹ 13.3 Lac
Quoted Amount
Calculate Bid Estimation
-5
×
%
₹ 12.7 Lac
Evaluation Notes How It Works ?

Result

No Result Available
Click here to view all tender results of this authority
Business Providers

No Business Providers available

Business Seekers

No Business Seekers available

https://bidassist.com/pricing/1?referer=Banners
7 DAY
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.
whatsapp chat