Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provision Of Blast Pens, Associated Taxi Links And Aprons Under Ge(af) Hasimara in Alipurduar, West Bengal, with an estimated contract value of Rs. 64,16,96,805. The bid opening date for this tender is 15-04-2019 and the last date for bid submission is 31-07-2019. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Opening Date15 Apr 2019
Closing Date31 Jul 2019
Tender Amount₹ 64,16,96,805 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F for sub main wiring with 2 runs of single core 4 Sqmm (Nominal area) PVC insulated unsheathed multi-stranded copper conductor cable LT 1100 Volts grade (FR-LSH), drawn through in and including stove enamelled conduit pipes of required size including earth continuity conductor using PVC insulated unsheathed copper conductor cable of size 4 Sqmm (Nominal area) (FR-LSH) connected to common earth dolly for independent 15 Amp socket out let complete all as specified and as directed. Note: A. Three runs of 4 sqmm conductor cable and one run of stove enamelled conduit pipe of required size shall be measured as one run length. B. Cutting chases, making hole to wall and making good disturbed surface if necessary shall be included in quoted lump sum of schedule 'A' Part-I and nothing extra shall be paid on this account.

500

-

-

... More
S & F for flame proof weather proof DB TPN 415 Volts 8 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 Nos M-20 cable entries for outgoing cable from bottom with cable glands suitable for hazardous area certified by CMRS Dhanbad for group II A & II B consisting of following complete all as specified and directed. Incoming (a) MCB TPN 32 Amp - 01 No Outgoing (a) MCB SP 20 Amp - 04 Nos (b) MCB SP 10 Amp - 07 Nos

10

-

-

... More
S & F for flame proof weather proof DB TPN 415 Volts 4 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 Nos M-20 cable entries for outgoing cable from bottom with cable glands suitable for hazardous area certified by CMRS Dhanbad for group II A & II B consisting of following complete all as specified and directed. Incoming (a) MCCB 4P, 125 Amp, 25 ka, 415 Volt - 01 No Outgoing (a) MCCB 4P, 125 Amp, 25 ka, 415 Volt - 01 No (b) MCB SP 10 Amp - 04 Nos

5

-

-

... More
EXTERNAL ELECTRIFICATION M & L for earthing complete with copper plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of size 20 x 3mm by means of nuts, bolts, check nuts and washers to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed.

4

-

-

... More
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
ITEM NO 11.33 (Contd...) (B) Alternator Alternator conforming to IS-13364 with standard design with IP 23 protection, suitably rated at 0.8 PF, 415 volts, 3-phase, 4 wires, 50 Hz, 1500 RPM, self excited brushless excavation and self regulated, band of automatic voltage regulator less than +/- 1% of rated voltage ( from no load to full load ) and class "H" insulation, alternator should be mounted on common single base frame and coupled directly to the engine (C) Acoustic Enclouser Acoustic enclose as per norms of central pollution control board (CPCB) issued by ministry of environment & forests, Govt. of india (D) Control panel cum AMF panel: The panel is equipped with as follows:- (i) MCCB FP 320 Amp 35 KA - 02 Nos (ii) Digital ammeter with selector switch - 01 No (iii) Digital voltmeter with selector switch - 01 No (iv) Digital frequency meter - 01 No (v) Instrument fuses & control wiring (vi) Pilot lamp for 'Load on' and 'Set running' (vii) Incoming & outgoing terminals (viii) AMF control accessories with control contract 200 TPN, microprocessor based relay & wiring etc - 01 No (ix) Over load protection system with relay - 01 No (x) Electronic type 3 phase muilti function meter - 01 No

-

-

-

... More
SCHEDULE "A" PART- II (SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents

1

-

-

... More
Construction of Double entry Blast Pens including flooring with earth traverse including link taxi to existing taxi track complete all as specified and as shown on drawings.

5

-

-

... More
ITEM NO 11.19 (Contd...) (c) The non circular fibre synthetic reinforcement shall be mixed with concrete, cost of the same shall be deemed to be included in the unit rate quoted for PQC nothing extra shall be paid on this account. (d) Cost of any admixtures required to achieve the desired properties of concrete shall be deemed to be included in the unit rate quoted for PQC nothing extra shall be paid on this account. (e) No price adjustment shall be applicable if excess quantity of cement content used in the work as approved in the Design Mix exceed 400 Kg. (f) Surface shall be finished by traverse brooming of maximum 1.5 mm deep as per ICAO or as per requirement of Air Force Authority. brooming shall be done through attachment in mechanical paver and rate is inclusive in quoted rate.

-

-

-

... More
SCHEDULE "A" Part - I (BUILDING WORKS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.

-

-

-

... More
M & L for preparing concrete top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc and applying evenly a tack coat with Paving Bitumen VG-10 @ 3.50 Kg per 10 Sqm complete all as specified and directed.

250

-

-

... More
Supply only pigments for use with cement green chromium oxide as per manufacturer instructions complete all as specified and as directed.

1200

-

-

... More
Construction of Sub station building including ramp (Sub station type SS-E) complete all as specified and as shown on drawings.

1

-

-

... More
S & F for 1 x 200 Watt flame proof LED High bay light fitting, including LED lamp and neccesary electric connection with suitable size copper cable complete all as specified and directed. Make: Sudhir Cat No. 1251 or equivalent approved make as per list of make

40

-

-

... More
M & L for 400 mm thick or less Pavement Quality concrete (PQC) of minimum field flexural strength 45 Kg /sqcm (Lower Control Limit) LCL after 28 days in pavement slab using minimum 400 Kg of cement per cum with 40mm graded crushed stone aggregate and using non circular synthetic fibre reinforcement @ 0.25% of weight of cement of PQC, laid in panels, spread and compacted using mechanical slip form paver (required span) and bull nosing / rounding off edges, curing, brooming, belting etc complete all as specified and directed. Note :- (a) All type of joints shall be measured and paid separately under respective items of Schedule ‘A’ / BOQ. (b) No deduction shall be made from concrete for space occupied by construction and dummy joint However, deduction shall be made for the space occupied by expansion joints

100

-

-

... More
M & L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 600 mm bore complete all as specified and as directed.

180

-

-

... More
S & F HT 11 KV LBSF panel out door complete with 630 amp load break switch, 200 amp D O set , earth switch, PCC etc complete all as specified and as directed.

1

-

-

... More
SCHEDULE "A" PART-X (DEMOLITION / DISMANTLING) Details of prepriced Schedule is given in tender documents

1

-

-

... More
TARMAC M & L for providing and laying 150 mm thick (compacted thickness) (in two layers of 75 mm compacted thick each) Wet Mixed Macadam (WMM), using gradings requirement of aggregate as per Table 400-II of yellow book of MORTH using mechanical paver and rolled with power roller of 8-10 tonne capacity of required camber and gradient complete all as speicified and as directed.

25

-

-

... More
S & F for flame proof Exhaust fan 300 mm sweep,1440 RPM, 240 volt, AC and including connected with twin core twisted flexible wire copper conductor cable of suitable size from ceiling rose to Exhaust fan complete all as specified and as directed. Make Sudhir Cat No. EF/140 or equivalent approved make as per list of make.

5

-

-

... More
EXTERNAL WATER SUPPLY M & L for construction of brick masonary valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar (1 : 4) on 100 mm thick PCC (1:4:8) D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, including PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in beding and coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 15 cm below ground level providing valve pit 40 mm X 40 mm X 6 mm angle iron frame all round the fixed point by means of 04 Nos holdfast 150 mm long made out of flat iron 40 mm X 6 mm embedded in PCC block (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) of size 250 mm X 200 mm X 150 mm including provision of hinges welded with Mild Steel cover 3 mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65 mm dia Godrej pad lock and 3 Nos. key and applying two coats synthetic enamel paint over a coat of red oxide primer on steel surface including necessary excavation and earth work in soft/loose soil complete all as specified and directed.

7

-

-

... More
Supply, installation, commissioning and testing of Silent diesel engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS: 10001/10002, ISO - 3046, BS - 5514, DIN - 6271 of capacity 250 KVA, 4 Stroke, designed to run continuously at 1500 RPM complete with the following accessories:- (A) Diesel Engine:- (i) Radiator cooling (ii) Radiator fan with guard (iii) Fly wheel with starter ring (iv) Dry type air cleaner (v) Vacuum indicator (vi) Mechenical governor (vii) Exhaust silencer (viii) Fuel filter (ix) Inline fuel pump (x) Water pump (xi) Lub oil filter (xii) 24 V electric start system complete with starter, battery charging alternator (xiii) Engine control panel consisting of starting key switch, lub oil pressure gauge, ammeter safety shut down system for low lube oil pressure and coolant temperature engine maintenance manual with spare parts list. (xiv) Exhaust pipe / stack upto 6m from top of shed with insulation structural steel required for supporting exhaust pipe / stack, fixed supports, sliding supports etc. (xv) First fill of lube oil and coolant. (xvi) Residential silencer eith cladding & supports

1

-

-

... More
ITEM NO 11.33 (Contd...) (E) Accessories: (i) Base frame of sturdy design - 01 No (ii) Fuel tank rectangle shape capacity suitable for running 12 hrs on full load. (iii) Battery 12 V not less than 100 AH maintenance free with leads & connecting accessoies - 02 Nos (F) Spare parts & tools: (i) Rotary pump diseal with 3 mt hose - 01 set (ii) Box spanner set complete with all sizes (iii) Oil filter set - 02 Nos (iv) Air filter complete with element - 02 Nos (v) Fuel filter set - 02 Nos (vi) AVR - 01 No (vii) Insulated rubber matt of size 900mm x 1500 mm x 3 mm thick - 02 Nos (viii) Jerrican MS sheet of required capacity - 02 Nos Note : (i) PCC foundation of adequate/required size extending 500mm all round more than size of DG set, as per manufacturer design. (ii) DG set shall be tested as type test routine as per IS in presence of GE/his rep. (iii) Contractor shall submit QAP ( quality assurance programme ) after the 15 days from placement of order for DG set testing to factory. DG set shall be dispatch after inspection clearance by inspecting officer. (iv) The contractor shall get approval of GE for the make of DG set they plan to procure (v) Prior manufacturing the general arrangement drawing design details of the DG set and AMF panel shall be got approved by GE

-

-

-

... More
M & L for Cutting to existing 80 mm dia CI pipe lines in position for insertion of new Tee of size 80 mm dia for branch connection as required complete all as specified and directed.

1

-

-

... More
Supply and installation for automatic operation of three phase Servo controlled naturally oil cooled stablizer, indoor type and desinged for input variation between 300V to 480V with out put voltage stablized at 415V with accuracy + 2.5% and speed of correction 8 voltage per second and of capacity 250 KVA including additional disconnecting chamber and extended copper bushing / busbar on primary & secondary side complete all as complete all as specified and as directed.

1

-

-

... More
EXTERNAL WATER SUPPLY AND EXTERNAL ELECTRIFICATION M & L for boring of holes carefully under road / pavement / hard standing by trenches using ultra sound technique and necessary machine without dameging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50 m from the site of work with and including HDPE pipe of 150 mm dia suitable for 0.4 mpa work pressure complete all as specified and as directed.

-

-

-

... More
M & L for forming 8 mm wide and 25 mm deep dummy / contraction joint using diamond cutter with initial saw cut with 3 mm blade soon after concrete sets for the depth of 110 mm and priming to 15 mm deep from top with approved primer applying masking tape of edge of joint to pavement accidental spillage of sealant and filling with polyeurethene based sealant to close cells (leaving 2-3 mm recess from top), medium density, cross linked polyethylene foam back up rod of 10 mm dia, for complete width of the joint, and removing the masking tape after filling of sealant all as per directions of the manufacturer complete all as specified and directed.

125

-

-

... More
Item No 11.17 (Contd...) (c) The mix design for soil stabilization to achieve minimum field soaked 'k' value of not less than 5 Kg/cm2/cm and minimum lab soaked CBR value of 8 with UCS 1 MPA shall be got done from an approved laboratory, using the proposed samples of moorum / red bazri and cement to be incorporated in the work. A trial bay will be laid and compacted approx. 50m long and 12 m wide. No payment shall be made for construction of trial length and quoted rate is deemed to include for this provision. Field test shall be carried out over the trial bay (field density, 'k' value & CBR value). On satisfactory test resuts further works to be processed. In the event of the test fail to give the min density & 'k' value, the mix shall be re-designed and fresh trial bay laid to get the satisfactory result. The failed trial bay to be removed and relaid without any extra cost. Curing of each layer of stabilised soil will be carried out as per IRC recommendations. (d) No price adjustment shall be applicable if excess quantity of cement is used / approved in the execution of work under this item. (e) This item may not be operated (fully / partially) as per relevant IS clause. (f) In case this item is not operated as per site soil condition / requirement the contractor will not have any claim whatso ever on this account for non execution of this item.

-

-

-

... More
SCHEDULE "A" PART- VI ( AREA DRAINAGE ) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
M & L for high density polythene film (transperent colour) in single layer of 400 Micron thickness virgin quality as per ASTMD 2103/IS 2508 laid with side and ovelapping not less than 300mm complete all as specified and directed

250

-

-

... More
S & F for flame proof ceiling fan 1200 mm sweep 240 volt AC, including down rod of suitable size, connected with twin core twisted flexible wire copper conductor cable of suitable size from ceiling rose to ceiling fan complete all as specified and as directed. Make Sudhir Cat No. CF/193 or equivalent approved make as per list of make.

35

-

-

... More
SCHEDULE "A" PART-IX (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents

1

-

-

... More
SCHEDULE "A" PART- VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
Construction of shed for DG Set including ramp complete all as specified and as shown on drawings.

1

-

-

... More
SCHEDULE "A" PART- IV ( INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
Supply, installation, testing and commissioning of CPRI approved LT Panel board double door, indoor type, 5 segment IP 54, weather and vermin proof, canopy on top over all size 1000 mm x 1000 mm x 800 mm made out of 3 mm thick CRCA sheet with all necessary frame work with angle iron of required size not less than 40 mm x 40 mm 6 mm cubical type duly powder coated paint over a coat of red oxide zinc chrome primer and aluminium bus bar of 150 Amps for three phase and neutral duly PVC laminated - 4 Nos including internal wiring by FR-LSH grade multistranded PVC insulated copper conductor of size not less than 1.5 sqmm duly marked, plate for fixing MCCB, MCB, time switch, indicator lamp etc with the following accessories and provision of PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as foundation of panel and bedding upto a height of 30 cm above gorund level complete all as specified and as directed. INCOMING (a) MCCB 4 pole, 415 V, 80 Amps 16 KA - 01 No (b) LED indicator lamp (RYB) - 01 Set (c) Voltmeter 0-500 Volts digital type with selector switch - 01 No (d) Ampmeter 0-200 Amps digital type with selector switch incuding CTs - 01 No OUTGOING (a) MCCB 4 pole, 415 V, 80 Amps 16 KA - 05 Nos (b) MCB TPN, 415 V, 32 Amps 10 KA - 02 Nos (c) MCB SPN, 230 V, 32 Amps 10 KA - 02 Nos (d) Time switch 230 volts single phase of 20 Amp rating with contactor.

5

-

-

... More
Note: Schedule of credit (SCHEDULE 'A' PART- XII) amount of Rs 27122.00 shall be deducted from the total quoted amount of BOQ.

-

-

-

... More
M & L for Providing and laying 150 mm thick cement concrete bas course as dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate confirming to IS:383, size of aggregate not exc 40 mm (grading and other parameters as per table 600-I of latest MORTH, IRC : SP : 49 Specification), of design mix, minimum cement content shall not leass than 200kg/Cum mixed in concrete batching plant, transported to site laid with paver including spreading and compacted by using 8 to 10 tones vibratory roller with and including necessary formwork finishing etc complete all as specified and as directed. Note: DLC under this item is to be provided to a width of 600 mm extra on both sides of proposed PQC layer by the contractor for easy movement of slip form paver. This extra width however shall not be measured and paid. However the rate quoted shall be deemed to include for this aspect.

25

-

-

... More
M & L for 300 mm thick Granular sub base or compacted subgrade using quarried stone in terstices filled and specified grading rolled and consolidated to required gradient and camber complete all as speicified and as directed.

25

-

-

... More
LIGHTENING PROTECTION AND EXTERNAL ELECTRIFICATION Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 mm x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed

-

-

-

... More
SCHEDULE "A" PART- VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
S & F for 1 x 12 Watt flame proof bulk head fitting retrofit type, including lamp and electrical connection with 3 core flexible wire of appropriate size from ceiling rose to light fitting complete all as specified and as directed. Make: Sudhir Cat No. BH/OA/124 or equivalent approved make as per list of make

20

-

-

... More
S & F for 1 x 12 Watt flame proof LED light fitting retrofit type, including LED lamp and electrical connection with 3 core flexible wire of appropriate size from ceiling rose to light fitting complete all as specified and as directed. Make: Sudhir Cat No. RVL/A/128/1 or equivalent approved make as per list of make

5

-

-

... More
S & F for 1 x 20 Watt 4 feet long flame proof Tube light fitting in aluminium alloy LM 6 with wire guard and reflectors retrofit type, including lamp and electrical connection with 3 core flexible wire of appropriate size from ceiling rose to light fitting complete all as specified and as directed. Make: Sudhir Cat No. FF/OA/1271/401 or equivalent approved make as per list of make

110

-

-

... More
SCHEDULE "A" PART-V ( TARMAC) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
M & L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised earth wire of size 4 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing complete all as specified and as directed.

30

-

-

... More
S & F for MS junction Box of size 280 x 130 x 95 mm in size with locking arrangement and applying two coats of aluminium paint over a coat of red oxide primer and 02 Nos aluminium bus bar and one no MCB SP 6 amps including suitable size clamp, nut, bolt and washer for fixing complete all as specified and as directed.

40

-

-

... More
M & L for 80mm bore CI sluice valve PN- 1.0, IS 14846-2000 with spindle iron (heavy duty) wheel head and both ends flanged and Mild Steel nut bolts and washers and pair of rubber/fiber gasket fixed in position having body & wedge rings - Bronze IS : 318 Gr. LTB2. spindle :- SS, IS : 6603 Gr. 12Cr12. Gland packing : greasy jute packing. flange drilling - IS 1538, table 4 & 6 complete all as specified and directed.

4

-

-

... More
S & F for 1 x 120 Watt flame proof LED flood light fitting, rotating type including LED lamp and neccesary electric connection with suitable size copper cable complete all as specified and directed. Make: Sudhir Cat No. FL/2C/1251 or equivalent approved make as per list of make

40

-

-

... More
M & L for Stabilising the moorum / red bazri (as approved) obtained from out side defence land breaking the oversize particles to required size, adding cement @ 2.5% (minimum) by weight of moorum / red bazri to be used in the item and water to the required quantity to maintain optimum moisture content of the mixture during consolidation, mixing the moorum / red bazri, cement and water in a mechanical mixing plant to obtain homogeneous mixture, laying the soil mixture in layers not exc 200 mm thick for a total depth of 400 mm by mechanical means, consolidating with suitable compacting plants such as 8 to 10 Ton vibratory roller etc under optimum moisture content to achieve atleast 98% of maximum dry density (Modified Proctor Density) and to achive k value of not less than 5.00 kg/cm2/cm determined in accordance with relevant IS code of practices and finishing the surface to the required levels, gradients etc complete all as specified and directed. Note : - (a) Moorum / red bazri for stabilization shall be obtained from out side defence land as approved by GE, cost of moorum / red bazri shall be included in the quoted rate of the item. (b) The tenderer's quoted rate shall deemed to include the cost of material (ie Moorum / red bazri, Cement) including carriage to soil stabilising plant and carriage of stabilised soil from plant to site for laying in pavement locations.

100

-

-

... More
S & F for sub main wiring with 2 runs of single core 1.5 Sqmm (Nominal area) PVC insulated unsheathed multi-stranded copper conductor cable LT 1100 Volts grade (FR-LSH), drawn through in and including stove enamelled conduit pipes of required size including earth continuity conductor using PVC insulated unsheathed copper conductor cable of size 1.5 Sqmm (Nominal area) (FR-LSH) connected to common earth dolly for one light / fan point / 3 pin socket out let of 5 amp complete all as specified and as directed. Note: A. Three runs of 1.5 sqmm conductor cable and one run of stove enamelled conduit pipe of required size shall be measured as one run length. B. Cutting chases, making hole to wall and making good disturbed surface if necessary shall be included in quoted lump sum of schedule 'A' Part-I and nothing extra shall be paid on this account.

4000

-

-

... More
Construction of RCC Static water tank / Fire fighting tank of capacity 110000 ltr complete all as specified and as shown on drawings.

1

-

-

... More
SCHEDULE "A" PART -XI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES.

-

-

-

... More
S & F for sub main wiring with 2 runs of single core 2.5 Sqmm (Nominal area) PVC insulated unsheathed multi-stranded copper conductor cable LT 1100 Volts grade (FR-LSH), drawn through in and including stove enamelled conduit pipes of required size including earth continuity conductor using PVC insulated unsheathed copper conductor cable of size 2.5 Sqmm (Nominal area) (FR-LSH) connected to common earth dolly for higt point complete all as specified and as directed. Note: A. Three runs of 2.5 sqmm conductor cable and one run of stove enamelled conduit pipe of required size shall be measured as one run length. B. Cutting chases, making hole to wall and making good disturbed surface if necessary shall be included in quoted lump sum of schedule 'A' Part-I and nothing extra shall be paid on this account.

800

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.