Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date27 Oct 2023
Closing Date10 Nov 2023
Tender Amount₹ 1,45,00,000
Costs
EMD
₹ 2,20,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_622654_2Bid Award Id
ViewTender No
8524/BAG/2023-24/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Returning, filling in,including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
257
-
-
Removing excavated soil/material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
157
-
-
M&L for PCC (1:4:8) (Type D-2 using 40mm graded crushed stone aggregate) as in foundation filling or mass concrete of poles,stays,struts or any other indicated work including form work (if required) complete all as specified and as directed.
8
-
-
M&L for PCC (1:2:4) (Type B-1 using 20mm graded crushed stone aggregate) for coping of poles/platform of feeder pillar box or any other indicated work including form work (if required) duly plastered and making the surface smooth and even by using extra cement complete all as specified and as directed.
0.5
-
-
M&L for GI pipe light grade with all new fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 100 mm complete all as specified and as directed.
60
-
-
M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and as directed. (Note:- Punned thickness shall be considered for payment).
100
-
-
Supply & laying unreinforced precast concrete cover, class HVP type 2, with peak of size 300mm x 180mm x 40mm with minimum average breaking load 350 Kg as per IS 5820 : 1970, ISI marked, complete all as specified and as directed.
6700
-
-
S&F Cross arms, bracings,supports,clamps and back plates fabricated from new structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts in any shape or size as indicated or directed by Engr-in-Charge and inclusive of one red oxide metal primar coat,one under coat and one finishing coat of approved quality aluminium paint complete all as specified and as directed.
4
-
-
M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed.
0.2
-
-
M&L steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified , type 410 SP 55 (11 meter long) complete including one primer coat of red oxide zinc chrome primer and two coats of aluminium paint including preparation of surface complete all as specified and directed.
Make:- Jindal/ Kwality steel Industries/ Bansal Metal works/ Calcutta Poles and Tubes
8
-
-
S&F lightning arrestors non linear resistor type confirming to IS 3070 (Part-3) 1993 complete line discharge class-3m, nominal discharge current 10 KA (Peak), 12 KV rated system, voltage peak valve high current impulse of 4/10 micro sec. Wave shape 100 KA (Peak), assembly suitable for 11 KV, long duration discharge class-ll with insulation level 28/75 KV and mounted on hot dip galvanised steel structure including all clamps,nuts, bolt and washers and connecting to earth with 32x6 mm Gl strip complete all as specified and as directed. Make:- Oblum/ Elpro/BHEL/Jaipuria Brothers
2
-
-
Supply and install triple pole mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level, current rating upto 200 Amps HT 11 KV outdoor type gang operated air break switch suitable for horizental or vertical mounting fixed type complete with 12 insulators of rating 200 Amps in and including expulsion fuse single pole for each phase in and including necessary operating pipe, clamps for fixing and operating handle complete all as specified and as directed. Make:- Pactil/ BHEL/Jaipuria brothers.
8
-
-
Supply, laying, connecting and testing HT cable, XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cable heavy duty with aluminium conductor, confirming to IS 7098, Part - II, 6.35KV (UE)/11 KV (E) grade, of size 95 sqmm, 3 core laid in pipes/ ducts/trenches/under road complete all as specified and as directed.
1500
-
-
S&F cable jointing kit 11 KV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable 95 sqmm 3 core complete all as specified and as directed.
14
-
-
S&F cable jointing kit for 11 KV grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 70 Sqmm to 95 sqmm complete all as specified and as directed.
2
-
-
S&F cable jointing kit for 11 KV grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 70 sqmm to 95 sqmm complete all as specified and as directed.
12
-
-
M&L for danger notice plate of 1.6 mm thick mild steel sheet with letters, figure and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and as directed.
25
-
-
M&L in replacement Earthing complete with GI earth plate electrode 60cm X 60cm X 6.0mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6 mm, by means nut bolt, nuts, check nuts and washer of the copper/Bronze protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1, using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
32
-
-
Supply fixing and laying earth continuity conductor or main earthing lead GI strip of size 32x6 mm with necessary jointing by means of GI rivets/nuts, washers, saddle and screw etc making test point and testing complete all as specified and as directed.
60
-
-
Supply, installation, commissioning and testing of HT feeder pillar box (CPRI approved) outdoor type of size 1.20m x 1.0m x 0.6m, powder coated, both side openable type, double door type, canopy on the top, two side ventilation, weather and vermin proof, outer shell shall be factory made of 3.15mm thick CRCA sheet and inner shell shall be made out of 2.00mm thick CRCA sheet with Space heater with thermostat - 01 No including nuts, bolts and washers, suitable for 400 Amps 3 Nos Aluminium bus bar with HT insulation tape R,Y,B mounting on the HT epoxy insulator for incoming and outgoing feeder with angle iron frame of size 50 mm x 6 mm angle iron including necessary foundation complete all as specified and directed.
1
-
-
Supply, install, testing & commissioning of expulsion fuse (Drop-out fuse unit) single pole 11000 volts grade upto 50 Apms rating complete all as specified and as directed.
2
-
-
Supply Installation, Testing & Commissioning of (2 LBS+2 VCB) 4way RMU, non- extendible outdoor type of rating 630 A aluminium busbar with a fault clearing capacity of 21 KA for 3 Sec, rated voltage 12 KV, operational voltage – 11 KV, frequency- 50 Hz, totally enclosed Ring Main Unit with IP 67protection for SF6 tank and IP 55 protection for outdoor enclosure with selfpowered microprocessor based numerical relay with over current and earth fault protection. Entire RMU should be tested for internal arc test of 21 KA for 1 Sec as per IEC 62271-200 standards including provision of necessary foundation with PCC (1:3:6) , type C-2 complete all as specified and as directed. (SMC Area-01,HQ Area-01,Tech area-01,Bomb dumb Area-01,PS 2 Area-01)
Note:-
(i) RMU Panel shall be manufactured by original manufacturer only i.e. Schinder/Siemens/Legrand/L&T/ABB/C&G. The firm specified cannot authorize any other vendors to manufacture RMU panels on their behalf and the panels so manufactured will not be accepted. The Panels manufactured by original manufacture’s only will be accepted and factory inspection will be done at original manfufacture’s plant only.
(ii) Vaccum interrupter, VCB and relay should be of same make.
5
-
-
S&F HT overhead line of 11KV on 11 meter steel poles with continuous GI earth wire, including earthing of poles cross arms, insulators etc and ACSR conductor of sizes 3 of 6/1 x 2.24 mm complete all as specified and as directed.
0.2
-
-
S&F cable route indicator with precast RCC slab (1:1.5:3) type A using 20 mm graded aggregate of size 75 cm X 30 cm X 75 mm thick duly embossed with "MES HT Cable" on the route of cable with PCC foundation complete all as specified and as directed.
Note:- Cost of of earthwork, PCC foundation 8mm dia TMT bar (5 Nos of bar along the length & 9 Nos of bar along width) painting the route indicator slabs with yellow color synthetic enamel paint deemed to be included in quoted rate .
40
-
-
Supply Testing, commissioning of 11KV, 630A , 26.3ka HT panel with cassette type VCB with spring charging motor rated 230VAC, triping coil & closing coil suitable for 110V DC, Enclosed in IP-4X, 2mm thick MS sheet steel enclosure withRAL7032 powder coating. With inbuilt anti-pumping system. 6NO+ 6NC contact.having complete set of Line PT and CT as per requirement and ratings,with Numerical Directional relay 110V DC, 1A, 50, 50N, 51, 51N, 64R, with RS485 relay, protection, Master trip relay- protection, 110VDC, Trip Circuit Supervision relay protection, 110VDC , 3 Elements Aux. relay 63 protection, 110VDC, Thermostat with "L" fixing bracket, Aux. Contactor with 2NO+2NC Block, 3PH, Digital Ammeter, CL-1, 3PH, Digital Voltmeter, CL-1, 3Ph, 4W MFM, CL-0.5 with RS485 Communication, 3Ph, 4W TVM, CL-0.5, Hooter, 110VDC, 8 Window Annunciator, 110VDC and other control accessories as per requirement. Following IEC shall be complied by VCB: IEC 62271-100, IEC 62271-102, IEC 62271-200 VCB shall have internal arc classification AFLR up to 26.3kA for 1 second VCB configuration will be (1 Incomer , 4 outgoings & 1 VCB I/C cum O/G type as per site condition.) Cassette type drawout VCB shall be of complete VCB & Complete horizontal drawout VCB without any additional arrangements for drawout. Drawout mechanish should be inbuilt in VCB cassette. VCB shall have Single latch door closing & optional rear door interlock. VCB shall have provision of Spring Charging Handle, Trip Rod, Moterised Rack Out Handle Available Separately.
Note:- (i) VCB panel shall be manufactured by original manfacturer only i.e. Schinder/Siemens/Legrand/L&T/ABB/C&G. The firm specified cannot authorize any other vendors to manufacture VCB panels on their behalf and the panels so manufuactured will not be accepted. The Panels manufactured by original manufacture’s only will be accepted and factory inspection will be done at original manufacture’s plant only.
(ii) Vaccum interrupter, VCB and relay should be of same make.
1
-
-
Taking down unserviceable/old ACSR conductor any size from over head lines, poles by removing binding wire and removal from site complete all as specified and as directed.
5
-
-
M&L for Dismantling unserviceable cross arms, clamps etc complete all as specified and as directed.
2
-
-
M&L for Dismantling insulator any type, any size from HT poles complete all as specified and as directed.
30
-
-
Dismantling old PCC pole/struts any size complete all as specified and as directed.
40
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements