Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Jul 2024
Closing Date3 Sep 2024
Tender Amount₹ 47,00,000 
Notes
Download

Costs

Summary

Repair/maint Of Sewage Treatment Plant, Repair/maintincluding Replacement Of Damaged Acbs And Mccbs And Allied Works And Repair/maint And Servicing Of Various Voltage Stablizers And Allied Works In Tech Assets At Af Station Hasimara Under Ge (af)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down the unserviceable parts from the non clog submersible pump of capacity 7.5 HP, 3 phase, 415 V including over hauling, servicing/cleaning throughly discharge/suction cases, impellers, shaft and re-assembling pump carefully including servicing , cleaning and painting the parts with two coats water proofing supper enamelled paint after preperation of surfaces manualy including repair/replacement of unservicable parts as required at site etc and re-assembling/re-installing the pump, complete all as specified and directed. Note:- (i) Spare/parts shall be measured & paid seperately as 'supply only'. (i) Labour charge for fixing parts shall deemed to be included in the unit rate.

2

-

-

... More
M & L for machine work to the worn out portion of non clog submersible pump shaft of capacity 7.5 HP capacity including metalling, cutting, polishing and checking the accuracy on the lath machine, complete all as specified and directed.

2

-

-

... More
Dismantling the induction motor from sewage sump/STP taking out burnt out winding wire from the stator of induction motor upto 3 HP and 1450 RPM of any make and rewinding with super enameled copper wire of appropriate size and number of turns as per manufacturers specifications including heat varnishing and testing of 3 phase, 415/440 volt and refixing after repair, complete all as specified and directed. Note:- (i) Copper winding wire shall be measured & paid separately as 'supply only'. (ii) Labour charge for fixing parts and transport shall deemed to be included in the unit rate.

1

-

-

... More
All as per item No 6.00 here-in-before but for 5 HP induction motor, complete all as specified and directed.

1

-

-

... More
All as per item No 6.00 here-in-before but for 7.5 HP induction motor, complete all as specified and directed.

1

-

-

... More
All as per item No 6.00 here-in-before but for 10/12.5 HP induction motor, complete all as specified and directed.

1

-

-

... More
Supply only ball bearing for non clog submersible motor as per existing, complete all as specified and directed.

2

-

-

... More
Supply only mechanical seal for non clog submersible motor as per existing, complete all as specified and directed.

2

-

-

... More
Supply only hydraulic oil for non clog submersible motor as per existing, complete all as specified and directed.

3

-

-

... More
Supply only impeller as per existing, complete all as specified and directed.

2

-

-

... More
Supply only impeller key as per existing, complete all as specified and directed.

2

-

-

... More
Taking out vertical non-clog pump set upto 10 HP capacity from sewage sump/STP, dismantling pump complete after disconnecting all electrical connections and repair/overhauling including replacement of worn out parts, complete all as specified and directed. Note : (i) Spares/parts required for replacement shall be measured and paid as 'Supply only'. (ii) Re-assembling, lowering in sewage sump to its original place, testing and transport will be included in the unit quoted rate.

2

-

-

... More
Supply only gun metal bush of vertical non-clog pump set upto 10 HP capacity, complete all as specified and directed.

10

-

-

... More
All as per item No. 16.00 here-in-before but impeller, complete all as specified and directed.

3

-

-

... More
All as per item No. 16.00 here-in-before but impeller key, complete all as specified and directed.

4

-

-

... More
All as per item No. 16.00 here-in-before but neck ring (bronze), complete all as specified and directed.

2

-

-

... More
All as per item No. 16.00 here-in-before but guide ring, complete all as specified and directed.

2

-

-

... More
All as per item No.16.00 here-in-before but lock bolt for impeller , complete all as specified and directed.

4

-

-

... More
All as per item No. 16.00 here-in-before but shaft sleeve, complete all as specified and directed.

3

-

-

... More
All as per item No. 16.00 here-in-before but oil seal for L B H, complete all as specified and directed.

5

-

-

... More
All as per item No. 16.00 here-in-before but oil seal for I B H, complete all as specified and directed.

2

-

-

... More
All as per item No. 16.00 here-in-before but grease pot for ball bearing, complete all as specified and directed.

2

-

-

... More
All as per item No. 16.00 here-in-before but shaft coupling (screwed), complete all as specified and directed.

3

-

-

... More
All as per item No. 16.00 here-in-before but coupling pin & bush, complete all as specified and directed.

4

-

-

... More
All as per item No. 16.00 here-in-before but ball bearing, complete all as specified and directed.

2

-

-

... More
All as per item No. 16.00 here-in-before but engine oil, complete all as specified and directed.

6

-

-

... More
All as per item No. 16.00 here-in-before but lock bolt for shaft coupling, complete all as specified and directed.

3

-

-

... More
All as per item No. 16.00 here-in-before but top shaft, complete all as specified and directed.

2

-

-

... More
Taking out centrifugal non-clog horizontal type pump from STP repair/overhauling/servicing of pump set by dismantling all components, re-metalling of worn out portion of shaft and grinding/polishing, replacement of bush, gland packing, gland studs, impeller key including filling of fresh lubricating oil in pedestal bearing oil chamber up to required level and greasing of bearing at non-diving end pump capacity upto 12.5 HP, complete all as specified and directed. Note : (i) Spares/parts required for replacement shall be measured and paid as 'Supply only'. (ii) Re-assembling, lowering in sewage sump to its original place , testing and transport will be included in the unit quoted rate.

2

-

-

... More
Supply only bearing ring for suction cover for horizontal pump sets capacity upto 12.5HP, complete all as specified and directed.

2

-

-

... More
All as peritem No. 33.00 here-in-before but gasket (asbestos), complete all as specified and directed.

2

-

-

... More
All as peritem No. 33.00 here-in-before but gland cover with stuffing box, complete all as specified and directed.

2

-

-

... More
All as peritem No. 33.00 here-in-before but gland packing (5 Nos in one set), complete all as specified and directed.

2

-

-

... More
All as peritem No. 33.00 here-in-before but ball bearing (N.D.E), complete all as specified and directed.

2

-

-

... More
All as peritem No. 33.00 here-in-before but thrust bearing (D.E), complete all as specified and directed.

2

-

-

... More
All as peritem No. 33.00 here-in-before but grease cup, complete all as specified and directed.

2

-

-

... More
S&F in repair rubber coupling/spider coupling, flexible type suitable for upto 10 HP pump set, complete all as specified and directed.

2

-

-

... More
S&F in repair fully automatic (FASD) star delta starter along with single phase preventor in powder coated enclosure with PU gasket suitable for 6 HP to 10 HP pump including all electric connection with ammeter and volt meter on/off & trip indicator including protection against phase failure, phase imbalance, phase reversal, complete all as specified and directed. Make : L&T model No. MK1 FASD or equivalent model in make BCH/Legrand/ABB/Schneider

1

-

-

... More
S&F 100mm bore sluice valve flanged end of class PN (1.6) with brass spindle, iron wheel handle clockwise closing with drilling hole, heavy duty, including necessary gasket, nuts and bolts, washer etc. including taking out old unserviceable sluice valve, complete all as specified and directed.

1

-

-

... More
S&F 150mm bore sluice valve flanged end of class PN (1.6) with brass spindle, iron wheel handle clockwise closing with drilling hole, heavy duty, including necessary gasket, nuts and bolts, washer etc. including taking out old unserviceable sluice valve, complete all as specified and directed.

1

-

-

... More
M & L for repair/servicing of existing sluice valve of 100mm bore after dismantling of upper cover, remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed.

3

-

-

... More
M & L for repair/servicing of existing sluice valve of 150mm bore after dismantling of upper cover, remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed.

3

-

-

... More
M&L for taking out primary and secondary bio filters assembly complete for overhauling dismantling its components, replacing of gaskets, applying of grease to the steel balls, replacing of U/S steel ball, and re-assembling after completion of overhauling, complete all as specified and directed.

2

-

-

... More
Bailing out the sludge/containminated water (organic or inorganic) including other foreign materials from sewage sumps of various sizes and depths as required by pumping with suitable pumping machinery and removing the same within 50m distance and disinfecting the area with sufficient quantity of bleaching powder and including removing and refixing of manhole covers as required, complete all as specified and directed. Note: (i) Temporary barricade and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate. (ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate. (iii) The operation shall be carried out once in every three months and every time shall be measured and paid saperately.

811

-

-

... More
Taking out/bailing out the sludge/semi solid materials including other foreign materials from sewage sumps of various sizes and depths as required by pumping with suitable pumping machinery and taking out sludge/semi solid materials/any other foreign materials from septic tanks etc and removing the sludge within 50m distance and deposited in a pit to be excavated and disinfecting the area with sufficeint quantity of bleaching powder over the earth fill and covered with earth filling upto 30cm depth of pit including removing and refixing of manhole covers as required, complete all as specified and directed. (Note: (i) Excavation and earth work for pit, bamboo matting, temporary barricade of the pit and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate. (ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate. (iii) The operation shall be carried out once in every three months and every time shall be measured and paid saperately.

320

-

-

... More
Cleaning of area around E/M installation and store yard by scraping the grass and creepers from roof and spraying grass killing chemical with spray gun, as per manufacturer's instructions for prevention of weeds and grass at surrounding of STP & E/M installations, complete all as specified and directed. Note : The cleaning of E/M installations can be carried out twice at same location during the currency of contract, subject to minimum 4 months gap.

820

-

-

... More
S&F PVC insulated, PVC sheathed, stranded copper conductor as in flat submersible water proof cable of size 6 Sqmm 3 core 1100 volts grade including taking down old unserviceable cable, complete all as specified and directed.

20

-

-

... More
M&L for testing and submit raw sewage water and treated water and submit the following test results:- (a) Samples to be taken from sewage pumping station Near Bala Ji Mandir, Near DSC accn, Near R S Ground, Near FWC & treated water from Main STP . (b) Submit all samples at the nearest Govt Test lab. The test for the following parameters has to be carried out:- (i) BOD (ii) COD (iii) Oil & Grease (iv) PH Value (v) TSS (vi) Feacel Colliform (vii) Residule chlorine (c) Submit the test report duly signed by appropriate Govt authority in every three month, complete all as specified and directed.

4

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level) and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 20mm bore and watering pipe GI medium grade of 20mm bore and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC (1:3:6) type C-2 all as shown in electrical plate No-3 of SSR part-I (2009) connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion, including demolition of old unserviceable earthing of any description, complete all as specified and directed. Notes : Proper earthing pit should be provided with pit cover and cost of the same shall be deemed to be included unit quoted rate.

2

-

-

... More
All as per item No 52.00 here-in- before but using GI earth strip 25 x 4mm as earth lead, complete all as specified and directed.

2

-

-

... More
Taking out existing boulders (75 to 200mm) complete from primary bio filter bed of dia 8.20m, depth of boulders bed 1.6m, cleaning the boulders using fresh water, cleaning bottom surface of the filter bed and re-filling the filter bed after cleaning boulders and removing the wastage/sediments out side defence land, complete all as specified and direccted.

1

-

-

... More
All as per item No 54.00 here-in- before but from secondary bio filter of dia 10.10m and depth of boulders 1.6m, complete all as specified and directed.

1

-

-

... More
Supply and lay boulders of size 75mm to 200mm in primary and secondary bio - filters, complete all as specified and directed.

30

-

-

... More
S & F in repair voltmeter digital type, complete all as specified and directed.

1

-

-

... More
S & F in repair ammeter digital type, complete all as specified and directed.

2

-

-

... More
S&F in repair on-off push button pendants with elements red /green/orange, complete all as specified and directed.

2

-

-

... More
S & F in repair rotary switch, 3 position, complete all as specified and directed.

3

-

-

... More
Attending day to day fault/complaint by providing skilled tradesman for automatic operation of MAFI and other substation equipment (PLC, VCB & ACB) installed at MAFI PS I including replacement of damaged flexible copper wire 1.5 sqmm single core into flexible conduit, monitoring of proper DC supply from battery bank for healthiness of system, replacement of minor parts like pla relay as per site requirement of PLC panel and VCB for automatic operation, complete all as specified and directed. (Note : Quoted rate shall deemed to be included the cost of minor parts & copper cable to be replaced/used in the item.)

40

-

-

... More
S&F in repair MCCB 630 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 500-630 Amp including providing new thimble / lugs of suitable size, complete all as specified and directed. Make : L & T Cat part No CM94106OOT1OG or equivalent model in Schneider / Legrand / ABB

4

-

-

... More
S&F in repair MCCB 400 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 320-400 Amp including providing new thimble / lugs of suitable size, complete all as specified and directed. Make : L & T Cat part No CM98403OOROOG or equivalent model in Schneider / Legrand / ABB

4

-

-

... More
S&F in repair MCCB 320 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 250-320 Amp including providing new thimble / lugs of suitable size complete all as specified and directed. Make : L & T Cat part No CM98403OOQOOG or equivalent model in Schneider / Legrand / ABB

3

-

-

... More
S&F in repair MCCB 200 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 200-250 Amp including providing new thimble / lugs of suitable size, complete all as specified and directed. Make : L & T Cat part No CM92109OOP1OG or equivalent madel in Schneider/Legrand/ABB

10

-

-

... More
S&F in repair MCCB 160 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 160-200 Amp including providing new thimble / lugs of suitable size, complete all as specified and directed. Make : L & T Cat part No CM92109OON1OG or equivalent model in Schneider / Legrand / ABB

10

-

-

... More
S&F in repair MCCB 125 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 125-160 Amp including providing new thimble / lugs of suitable size, complete all as specified and directed. Make : L & T Cat part No CM92108OOM1OG or equivalent model in Schneider / Legrand / ABB

9

-

-

... More
S&F in repair MCCB 100 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 100-125 Amp including providing new thimble / lugs of suitable size, complete all as specified and directed. Make : L & T Cat part No CM92108OOL1OG or equivalent model in Schneider / Legrand / ABB

14

-

-

... More
M & L for servicing / maintenance of air circuit breaker by authorised rep including control wiring for auto operation of VCB, ACB, control PCB for DG etc, cleaning of all parts, cleaning arc contact, replacement of damaged thimble and replacement of burnt out wiring, relays and all other minor accessories to make it serviceable including testing of equipment for auto/ mannual operation, complete all as specified and directed.

12

-

-

... More
M & L for replacement of burnt out closing / tripping / shunt /UV coil of ACB by authorised rep of manufacturer of existing ACB including interlock wiring with suitable size copper wire, complete all as specified and directed.

9

-

-

... More
M & L for Arcing contact assembly (set of 01 No. fixed 01 No. moving) suitable for ACB 630 Amp to 1000 Amp complete with all accessories, complete all as specified and directed.

6

-

-

... More
M & L for main isolating contacts (Jaw contacts) suitable for ACB 630 Amp to 1000 Amp complete with all accessories, complete all as specified and directed.

8

-

-

... More
M & L for main fixed contacts contacts (Upper terminals) suitable for ACB 630 Amp to 1000 Amp complete with all accessories, complete all as specified and directed.

8

-

-

... More
M & L for Arc chutes suitable for ACB 630 Amp to 1000 Amp complete with all accessories, complete all as specified and directed.

20

-

-

... More
M & L for mannual charging handle for ACB 630 Amp to 1000 Amp complete with all accessories, complete all as specified and directed.

5

-

-

... More
M & L for charging motors 220 V AC suitable for ACB 630 Amp to 1000 Amp complete with all accessories, complete all as specified and directed.

6

-

-

... More
Supplying and laying synthetic rubber insulated mats 2.5mm thick of size 2m x 1m, complete all as specified and directed.

31

-

-

... More
M & L for removing of flashed carbon from Air Circuit Breaker, MCCB, contactors, bus bar chamber etc of LT panel, AMF panel, junction box by cleaning with cleaning agent properly and replacement of burnt out parts like spreader link, suitable size lugs,replacement of bus bar insulator, replacement of damaged handle of switchgears and applying heavy duty HVBT tape on bus bar with colour coding on each phase complete all as specified and directed.

150

-

-

... More
M & L for servicing of float cum boost charger by cleaning of all terminals, applying pertroleum jelly on terminals, filling of distilled water into battery, replacement of burnt out terminals, replacement of burnt out parts of charger, rotating switch, float / cum boost charger switch, charge rate selector switch, trickle / boost charger rotating switch, including replacement of burnt charge controller PCB, replacement of suitable size dry type/ air cooled transformer , rectifier of chargerand all other work required to carried out for functional of float cum boost charger, complete all as specified and directed.

4

-

-

... More
Servicing and repair of servo voltage stabilizer of capacity upto 50 KVA by manufacturer's rep after disconnecting all electrical connections of stabilizer and check the auto/manual function of stabilizer, to check the oil level, oil seal leakage if any, check voltmeter and Amp meter working condition or not. Taking out top cover of stabilizer for replacing defective spares/ items, cleaning the dust by air blower, check the neutral and earthing connections properly to check all nuts, bolts tightining and refixing the same in existing position and reconnect all the incoming/ outgoing cables properly including testing and commissioning, complete all as specified and directed. Note :- (i) Replacement of defective spares for making the voltage stabilizer units in satisfactory working condition shall be measured & paid separately under relevant items as 'Supply only' (ii) Labour charges for taking out old spares & refixing of new spares shall deemed to be included in the unit quoted rate.

4

-

-

... More
All as per item No. 80.00 here-in-before but 75 KVA to 150 KVA, complete all as specified and directed.

5

-

-

... More
All as per item No. 80.00 here-in-before but 200 KVA to 630 KVA, complete all as specified and directed.

4

-

-

... More
All as per item No. 80.00 here-in-before but 630 KVA to 1000 KVA, complete all as specified and directed.

2

-

-

... More
Supply only electronic servo circuit card (PCB), complete all as specified and directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT LTD.

30

-

-

... More
Supply only servo control panel, complete all as specified and directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT LTD.

12

-

-

... More
Supply only trigger (control) transformer 9V/18V, complete all as specified and directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON)

18

-

-

... More
Supply only push button/auto-manual switch/micro switch/potentio meter/limit switch/lever switch, complete all as specified and directed. (Make:- AE/MECO/ L & T (RISHABH)/AMTL/SECURE/ C & S ELECTRIC/ DUCATI/ RAAS CONCORD)

20

-

-

... More
Supply only indicator lamp, complete all as specified and directed.

30

-

-

... More
Supply only carbon brush, complete all as specified and directed. (Make:- AE/MECO/ L & T (RISHABH)/AMTL/SECURE/ C & S ELECTRIC/ DUCATI/ RAAS CONCORD)

30

-

-

... More
Supply only ammeter with CT (digital/analag) with connection controlling switch (suitable size and shape), complete all as specified and directed.

12

-

-

... More
Supply only voltmeter 0-400 volts flush type with connection controlling switch (suitable size and shape), complete all as specified and directed.

12

-

-

... More
Supply only rotary switch 5 Amp for R.Y.B phase, complete all as specified and directed.

16

-

-

... More
Supply only PCB holder, complete all as specified and directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON)

30

-

-

... More
M & L for refilling/topping up/replacement of stabilizer oil with new dehydrated stabilizer oil. Open lid cover of stabilizer including changing of gasket set if required complete and re-fixing of top lid cover without any damage to stabilizer suitable for working voltage 440 volts grade including necessary dehydration to achieve dielectric strength min 40 KV including internal/external connection and testing on load of stabilizer, complete all as specified and directed. (Make:- HPCL(SEETAL)/ HP (SEETAL)/ SERVO/GULF/ CASTROL)

1800

-

-

... More
Note: An amount of Rs.36,761.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.

-

-

-

... More
Supply and fixing energy efficient ‘LED Flood Light 120 W LED luminaire with Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.