Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date3 Oct 2024
Closing Date8 Nov 2024
Tender Amount₹ 20,19,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F switch piano, flush button, single pole ,one way, 5 Amps, 230 volts complete all as specified and directed. [Total Qty: 28.00(Part-I)+ 66.00(Part-V)+ 57.00(Part-VI)= 151.00]

151

-

-

... More
S &F energy efficient mettalic, powder coated Exhaust fan, steel body AC single phase. Operating voltage 220- 240 Volt, frequency 50Hzs, having blade sweep 300 mm ,1350-1400 RPM air delivery not less than 1160-1600 CMH ,supply complete with louvers and frame fixed with suitable size GI bolts, nuts and washers duly grouted and connecting up with 0.75 Sq.mm size 3 core PVC insulated flexible cable with multistranded copper conductor from ceiling rose to connector of exhaust fan complete all as specified and directed. [Total Qty : 08.00(Part-I)+ 10.00(Part-V)= 18.00] [Note : Purchase voucher and warranty certificate to be produced for claiming of payment.]

18

-

-

... More
S &F energy efficient mettalic, anti dust powder coated,Exhaust fan, steel body, 4 blade, AC single phase. Operating voltage 220- 240 Volt, frequency 50Hzs,1400RPM having blade sweep 450 mm , air delivery not less than 6120 CMH ,supply complete with louvers and frame fixed with suitable size GI bolts, nuts and washers duly grouted and connecting up with 0.75 Sq.mm size 3 core PVC insulated flexible cable with multistranded copper conductor from ceiling rose to connector of exhaust fan complete all as specified and directed. [Total Qty : 20.00(Part-I)+ 26.00(Part-V)= 46.00] [Note : Purchase voucher and warranty certificate to be produced for claiming of payment.]

46

-

-

... More
S & F MCB ( single pole & neutra) DB (double door),8 way sheet metal enclosure SPN 240 V 50 Hz horizontal conforming to IEC 61439- 3, suitable for flush mounting with 200 A rated insulated & shrouded copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set and cable ties for cable management, IP 43 & IK 09 protection with provision for FP RCBO as incomer and SP MCBs as outgoing, all complete as specified and directed. Note : MCBs shall be measured and paid in relevant items.

2

-

-

... More
S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, 'C' curve having breaking capacity Icon = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconvex IP 20 protected lower terminals and sliding shutters, etc. of 20 Amp, single pole & neutral 240V, 50 Hz complete all as specified and directed.

4

-

-

... More
S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, 'C' curve having breaking capacity Icon = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconvex IP 20 protected lower terminals and sliding shutters, etc. of 40 Amp, single pole ,240V, 50 Hz complete all as specified and directed.

4

-

-

... More
M & L earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized Iron earth strip 32 X 6 mm thick by means of nuts bolts washers etc as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, galvanized iron pipe light grade 15 mm diameter for protection of earthing wire, (To be concealed in wall/floor) connected to earthing test point, all as shown in electrical plate No. 3 of MES Schedule Part I. , connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a PCC (1 3 6) type C1 using 20mm graded stone aggregate earth chamber ,40mm thick RCC cover type B1 (1 2 4 ) B1 using 20mm graded stone aggregate with 8 mm dia tor reinforcrment 100mm c/cand 12 nn dia MS bar handle on top of cover on ground level, 20 mm dia GI watering pipe, funnel, etc. complete and testing resistance in completion all as specified and directed.

4

-

-

... More
Sch A, Part - II Provn of Air circulator for living Accn for ADB Camp (MINOR WORK - 10)

-

-

-

... More
S&F of Staineless Steel (SS-304) automatic turbo ventilator, light weight, Non power driven , maintanence free, noise free, whetherproof, strom & rain resistance, leakage proof rotation at lowest wind velocity, Shaft machined central less Grinder for precise quality bush, friction rotation even at lowest wind velocity. size and grade (SS) minimum Turbine Dia - 685 mm, minimum Height 360 mm minimum Weight -5.25 kgs (approx), blade thickness - 0.50 mm incl mounting ring 95 mm width with 2 nos of 4.0mm deep ribs for extra strength and fix over polycarbonate base plates on roofs with self drilling screw, all as specified and directed. (Note : S&F Polycarbonate based plate shall be make & paid separately.)

36

-

-

... More
S&F of polycarbonate ventilator base plates of 3' 6'' x 5' 6" fixing over the roof sheet incl the cutting of sheet and fixing arrangement with screwed for used to fix Turbo complete all as specified and directed.

36

-

-

... More
Sch A, Part - III Provision of 01 x Chimney with Hy duty exhaust fan for ADB camp (MINOR WORK - 11)

-

-

-

... More
M & L point wiring using ISI marked 1.1 kV grade two single core FR LSH PVC insulated, unsheathed stranded copper conductor of size 4.0 sqmm flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors , conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm NB PVC medium grade ,casing & caping , conforming to IS:14927 (Part 2)- 1983, colour-coded as specified in IS: 11353- 1985, including factory made sunken, galvanized, not less than 1.60 mm thick boxes, 3.15mm thick plastic laminated sheet top cover,having 4 Nos nuts to 4 corners for One 3 pin switch socket outlet, 15 amps, independent, complete with one 4.00 sqmm FR LSH ,PVC insulated unsheathed multistandard copper conductor 1100 volts grade green colour for earth continuity complete all a specified and directed. Note : Circuit wire from DB to switch boards shall be included in the quoted rate. No additional payment will be paid to the contractor for the circuit submain. (a) for One 3 pin switch socket outlet, 15 amps, independent. [Total Qty: 2.00(Part-III)+ 10.00(Part-IV)= 12.00]

12

-

-

... More
S & F switch socket combination ,2 in 1, 3 pin, 15/16 amps, flush type complete all as specified and directed.

2

-

-

... More
Supply, commisoning and installing of Exhaust chimney for 100 men cook house with SS Hood, GI Duct line, Tubular axial Fan- motors and all its accessories with minimum dimension details as per following for its smooth running including necessary electric connection, Motor Starter , welding, dranaige connection, scaffoldings, civil jobs required for instalation complete all as specified and directed. (i) SS Two Burner Cooking Range - Size 44''x 24'' x 34'' - 01 No. (ii) SS Chapati / Dhosa Hot Plate with Puffer - Size 39'' x 26'' x 34'' - 01 No. (iii) SS Hood With Baffle Filters - Size 48'' x 30'' x 18'' - 02 No. (iv) GI Duct line with all support - 20' rft. (v) Tubular Axial fan with 3PH, 2HP motor capacity 8000CFM - 01 No. [Note: Purchase voucher and warranty certificate to be produced for claiming of payment.]

1

-

-

... More
M&L sub main wiring in & including not less than 25 mm NB PVC medium grade ,casing & caping , conforming to IS:14927 (Part 2)- 1983, colour-coded as specified in IS: 11353- 1985 with two single core FRLSH PVC insulated unsheathed cable, 1100 volts, grade having stranded copper conductor of 4.0 sqmm nominal cross sectional area conforming to IS: 694- 1990 each drawn into and all accessories including one single core 2.5 sqmm FRLSH copper conductor for earth continuity conductor connected to earth dolly complete all as specified and as directed. Note : Two run single core cable, one run of earth conductor and one run of PVC capping cashing/conduit shall be measured as a unit length.

30

-

-

... More
Sch A, Part - IV Provn of Electrical Geysers for OR Bathroom for Head Quarter ADB Camp (MINOR WORK - 7) :

-

-

-

... More
S&F sheet metal enclosure with socket, plug top and MCB Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volts complete all as specified as directed.

10

-

-

... More
S & F electric water heater, digital display storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated,single phase 230 volt complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc.to provide heated water at the desired point complete all as specified and directed. [Note: Purchase voucher and warranty certificate to be produced for claiming of payment]

10

-

-

... More
Supply and laying galvanised iron pipe of size 15 mm bore of medium grade with all tube fittings ( such as bends, elbows, tees, short pieces of medium grade , connectors, back-nuts, caps, plugs and unions etc.) laying in trenches/ floors/ ducts and also cutting pipes, screwing, and for making forged bends on piping as required including and complete all as specified and directed.

66

-

-

... More
S & F of Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including all required fittings and complete all as specified and directed.

10

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.

70

-

-

... More
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation laying of cables, etc., or for shafts, wells, cesspits, manholes, pier holes, etc., 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ lose soil complete all as specified and directed.

15.75

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil under floor complete all as specified and directed.

6.91

-

-

... More
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.

8.84

-

-

... More
M&L sand cushioning with layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches and necessary punning down as per procedure for cable protection tested complete all as specified and directed. (Note : Only Punned thickness(180mm) shall taken for payment.)

5.67

-

-

... More
Supply and laying Sub Class "B" Bricks Designated 75 as in cable Protection complete all as specified and as directed.

0.5

-

-

... More
M & L earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized Iron earth strip 25 X 4 mm thick by means of nuts bolts washers etc as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, galvanized iron pipe light grade 15 mm diameter for protection of earthing wire, (To be concealed in wall/floor) connected to earthing test point, all as shown in electrical plate No. 3 of MES Schedule Part I. , connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a PCC (1 3 6) type C1 using 20mm graded stone aggregate earth chamber ,40mm thick RCC cover type B1 (1 2 4 ) B1 using 20mm graded stone aggregate with 8 mm dia tor reinforcrment 100mm c/cand 12 nn dia MS bar handle on top of cover on ground level, 20 mm dia GI watering pipe, funnel, etc. complete and testing resistance in completion all as specified and directed . [Total Qty: 01.00(Part-IV)+ 06.00(Part-VII)= 07.00]

7

-

-

... More
Sch A Part - V Provision of Exhaust Fans of various Sizes ( both Steel & plastic body ) and Ceiling Fans for Junior Commissioned Officers/Other Rank living shelters & Junior Commissioned Officers of ADR (MINOR WORK - 2)

-

-

-

... More
S & F stepped type(min 5 step) electronic Fan regulator, flush type,240V,single phase on the existing phenolic laminated sheet etc complete all as specified and directed.

30

-

-

... More
S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. [Note : Purchase voucher and warranty certificate to be produced for claiming of payment.]

30

-

-

... More
Sch A, Part - VI Provision of LED tube lights in replacement of LED bulb at various building at ADR : (MINOR WORK - 3)

-

-

-

... More
S & F LED lights fitting 1x 20W, 230V, decorative box type with driver heavy duty having THD110% with powder coated metallic housing and high quality poly carbonate diffuser connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, holder including LED tube light connecting up complete all as specified as directed . [Note: Purchase voucher and warranty certificate to be produced for claiming of payment.]

240

-

-

... More
Taking down old unserviceable incandense lamp/decorative light with all fitting complete all as specified as directed.

230

-

-

... More
Sch A, Part - VII Provision of Lighting Arrestor (Communication complex) of ADBS Company (MINOR WORK - 12 )

-

-

-

... More
M&L Air Termination , single pointed, copper rod 12mm dia and of length 1.5 m of solid copper material with all its accessories complete all as specified and directed.

6

-

-

... More
S&F Test Point terminal block made of gun metal or phosphours bronze size 75 X 75 X 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex. Head screw complete all as specified and directed.

6

-

-

... More
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicted situation for loop earthing but by using Aluminium strip 25 X 3 mm strip as earthing lead etc., complete all as specified and directed.

50

-

-

... More
M & L for Low tension aerial copper Lightning arrester expulsion type complete with all fittings, 30 kilo amp discharge capacity, distribution class to arrest upto a radius of 107 mtr radius having a GI Mast 5mtr, 40mm dia, with all wire accessories, strike counter 6 digit, test link box double bus bar, single core copper cable of size 7.00 Sqmm (approx 50mtr ), Earthing electrode 17.2/3 MTPCBR with 50 Kg bfc bag, Pit coverpolyplastic Big(3 nos) complete all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.