Water Proofing Tenders
Water Proofing Tenders
Southern Railway - SR Tender
Goods
Paints and Enamels...+2Electrical Goods and Equipments, Electrical and Electronics
Ireps
Dharmapuri, Tamil Nadu
Details: Description:- Supply, Installation, Testing, And Commissioning Of Exterior Bis Registered 24w 24v Dc Rgbw
linear Led Wall Washer Luminaire For Facade Lighting With Extruded Aluminum Housing, Powder-coated Finish, And
clear Toughened Glass. With All Leds On, Minimum System Lumen Efficacy Equal To Or Greater Than 62.9 Lm/w.the
luminaire Shall Be Capable Of Producing Dynamic Color-changing Light With 16 Million Colors As The Light Fixture
should Be Programmable Using 8-bit Control Dmx512 Protocol / Ethernet Based Control. Luminaire Should Be
complete With A Dedicated Lens Made Up Of Ul/vde Approved Pc For Each Led, Offering Beam Angle Of Different
types Such As Narrow, Medium, Wide Or Elliptical As Per The Site Requirement. The Fixture Should Be Erected With
the Necessary Required Brackets And Should Have Constant Locking Hinges For Simple Position Control From Various
angles Without Special Tools. Fixture Shall Be Suitable To Operate At An Ambient Temperature Range Of -30°c To
50°c And Complete Luminaire Shall Be Ip66 And Ik07 Rated. Led Life Time Shall Be At Least L70@ 25c @ 50000
burning Hours At 25°c. Led Should Be Of Nichia/osram/seoul/philips/ Lumileds /cree /lednium /
avago Make. The Product Should Be Bis Approved With R Number Mentioned On Product Label. To Be Supported
with Product Test Reports - Lm79, Bis Report And Leds Test Reports. Luminaire Shall Be Conforming To Bis I.e.
is10322 (part 5/sec 5) And Shall Be Complete With All Necessary Accessories Required For Proper Working Of Fixture
including Weather Proof Connection Cables, Water Proof Connectors Etc. As Required. This Includes Crane Charges
if Any For Height Work. (warranty Period Of 5 Years). All Test Reports And Technical Data Sheets To Be Submitted To
the Competent Authority For Approval. After Installation, Assembling And Commissioning Contractor Should Ensure
that All Parts Of The Light Are Properly Fixed And Put It Into Running Condition. The Entire Work Should Be Carried Out
as Per The Instructions Of Site Engineer. Testing Of The Fixtures To Be Done In The Presence Of Site Engineer For A
minimum Period Of 1 Week
Closing Date10 Jul 2024
Tender Amount₹ 44 Lac
Karnataka Power Corporation Limited - KPCL Tender
Security and Emergency Services
Bengaluru Urban, Karnataka
Details: All The Extinguishers Shall Be Kept In Healthy Working Condition.check And Inspect The Condition / Operational Readiness Of Fire Extinguishers.check And Inspect Expiry Date On Fire Extinguishers.empty Cylinders And Expired Cylinders Shall Be Segregated And Listed For Refilling.carry Out The Refilling Works Of Co2,mechanical Foam,water Co2 And Abc Fire Extinguishers For Those Cylinders Which Are Empty And Crossed Expiry Date With Approval From Enginer In-charge And All Refilling Works Of Mechanical Foam,water Co2 And Dcp Shall Be Carried Out At Bhadra Generating Station Itself. Refilling Of Co2 And Abc Fire Extinguishers Shall Be Carried Out At Firm Works And Refilled Cylinders Shall Be Brought Back And Installed Within 07 Days.all Defective And Damaged Parts / Spares Of The Fire Extinguishers Shall Be Listed And Submitted. Such Damaged Parts / Spares Shall Be Supplied And Replaced With Approval From Engineer In-charge Within Reasonable Time. Check / Inspect And List Out Defective Fire Extinguishers And Issue Condemnation Certificate.carryout The Pressure Testing Of Water Co2, Mechanical Foam, Dcp, Abc And Co2 Type Fire Extinguishers Once In The Contract Period.carry Out Quarterly Over All Supervision And Maintenance Of The Fire Extinguishers System In A Year And Label The Cylinders For Healthiness And Next Due Date Of Maintenance. Water Proof Labels / Covers Shall Be Used For Outdoor Fire Extinguishers. Refilling / Recharging Shall Be Carried Out Using Quality Materials Only. The Spare For Fire Extinguishers Parts Shall Be Supplied By Kpcl.there Are 06 Fire Hydrant Points At Left Bank Power House And 02 Fire Hydrant Points At Right Bank Power House Of Bhadra Generating Station.carry Out Quarterly Over All Supervision And Maintenance Of The Fire Hydrant Systems In A Year And Report Shall Be Submitted For Healthiness Of The System. Carry Out Checks Of All The Fire Hydrants For Its Operational Readiness.checking Of Pipelines, Valves, Nozzles, Hoses, Hose Reel Drums And Couplings For Healthy Condition. Any Abnormalities In The System Shall Be Rectified With Approval From Engineer In-charge.the Firm Has To Conduct Fire Fighting Training In Theory, Practical And Panic Mock Drill Once In A Year. The Training Program Shall Be Conducted At Bhadra Generating Station. Time And Date Of The Training Program Shall Be Decided And Intimated By Engineer In-charge.
Closing Date28 Aug 2024
Tender Amount₹ 1.5 Lac
Indian Council Of Medical Research - DHR Tender
Goods
Healthcare and Medicine
GEM
Pondicherry, Pondicherry
Details: Ldl Cholestrol With Calibrator,2x30m,2x10ml , Hba1c With Calibrator Set,2x15ml,2x5ml , Xl Multical,4x3ml , Autowash, Ac,al, 5x4ml , Autowash Kit,10x100ml , Erba Norm Kit , Erba Path Kit , Urea 5x22ml,5x 6point8ml , Micro Albumin With Calibrator 1x5ml,2x25ml , Calcium 5x6ml , Creatinine,jaffes,5x44ml,5x11ml , Glucose,10x44ml , Triglycerides ,5x11ml,5x4ml , Cholesterol,5x11ml , Hdl Cholestrol With Calibrator, 4x30ml,4x10ml , Erba Norm 4x5ml , Erba Path 4x5ml , Multical 4x3ml , Erba H3 Control Hematology,qc , Director Ldl R1 2x30,r2 2x10 , Erba 180 Cuveette , Rotar , Erba Wash Solution System Pack 10,100ml , Alkaline Phosphatase R1 2x44,r2 , Sgot R1, 4x35ml,r2 4x18 Point1 Ml , Albumin R1 10x44ml , Direct Hdl R1-4x30ml,r2-4x10ml , Crp R1 1x40ml,rx 1x10ml , Aso 1x22,1.5x5 , Sgpt R1 4x35ml,r2 4x18point1ml , Plate Sealer, 100 Per Pk , Water Proof Temperature And Humidity Data Logger , Anti A,b,c,d Blood Grouping Kit , Anti H Lectin Antisera , Anti A1 Lectin Antisera
Closing Date3 Jul 2024
Tender Amount₹ 13 K
This is an estimated amount, exact amount may vary.
Southern Railway - SR Tender
Goods
Electrical Goods and Equipments...+1Electrical and Electronics
Ireps
Namakkal, Tamil Nadu
Details: Description:- Supply, Installation, Testing, And Commissioning Of Exterior Bis Registered 24w 24v Dc Rgbw
linear Led Wall Washer Luminaire For Facade Lighting With Extruded Aluminum Housing, Powder-coated Finish, And
clear Toughened Glass. With All Leds On, Minimum System Lumen Efficacy Equal To Or Greater Than 62.9 Lm/w.
the Luminaire Shall Be Capable Of Producing Dynamic Color-changing Light With 16 Million Colors As The Light Fixture
should Be Programmable Using 8-bit Control Dmx512 Protocol / Ethernet Based Control. Luminaire Should Be
complete With A Dedicated Lens Made Up Of Ul/vde Approved Pc For Each Led, Offering Beam Angle Of Different
types Such As Narrow, Medium, Wide Or Elliptical As Per The Site Requirement. The Fixture Should Be Erected With
the Necessary Required Brackets And Should Have Constant Locking Hinges For Simple Position Control From Various
angles Without Special Tools. Fixture Shall Be Suitable To Operate At An Ambient Temperature Range Of -30°c To
50°c And Complete Luminaire Shall Be Ip66 And Ik07 Rated. Led Life Time Shall Be At Least L70@ 25c @ 50000
burning Hours At 25°c. Led Should Be Of Nichia/osram/seoul/philips/ Lumileds/cree/lednium/ Avago
make. The Product Should Be Bis Approved With R Number Mentioned On Product Label. To Be Supported With
product Test Reports - Lm79, Bis Report And Leds Test Reports. Luminaire Shall Be Conforming To Bis I.e. Is
10322 (part 5/sec 5) And Shall Be Complete With All Necessary Accessories Required For Proper Working Of Fixture
including Weather Proof Connection Cables, Water Proof Connectors Etc. As Required. This Includes Crane Charges
if Any For Height Work. (warranty Period Of 5 Years). All Test Reports And Technical Data Sheets To Be Submitted To
the Competent Authority For Approval. After Installation, Assembling And Commissioning Contractor Should Ensure
that All Parts Of The Light Are Properly Fixed And Put It Into Running Condition. The Entire Work Should Be Carried Out
as Per The Instructions Of Site Engineer. Testing Of The Fixtures To Be Done In The Presence Of Site Engineer For A
minimum Period Of 1 Week.
Closing Date12 Feb 2024
Tender Amount₹ 21 Lac
Southern Railway - SR Tender
Goods
Electrical Goods and Equipments...+1Electrical and Electronics
Ireps
Salem, Tamil Nadu
Details: Description:- Supply, Installation, Testing, And Commissioning Of Exterior Bis Registered 24w 24v Dc Rgbw
linear Led Wall Washer Luminaire For Facade Lighting With Extruded Aluminum Housing, Powder-coated Finish, And
clear Toughened Glass. With All Leds On, Minimum System Lumen Efficacy Equal To Or Greater Than 62.9 Lm/w.
the Luminaire Shall Be Capable Of Producing Dynamic Color-changing Light With 16 Million Colors As The Light Fixture
should Be Programmable Using 8-bit Control Dmx512 Protocol / Ethernet Based Control. Luminaire Should Be
complete With A Dedicated Lens Made Up Of Ul/vde Approved Pc For Each Led, Offering Beam Angle Of Different
types Such As Narrow, Medium, Wide Or Elliptical As Per The Site Requirement. The Fixture Should Be Erected With
the Necessary Required Brackets And Should Have Constant Locking Hinges For Simple Position Control From Various
angles Without Special Tools. Fixture Shall Be Suitable To Operate At An Ambient Temperature Range Of -30°c To
50°c And Complete Luminaire Shall Be Ip66 And Ik07 Rated. Led Life Time Shall Be At Least L70@ 25c @ 50000
burning Hours At 25°c. Led Should Be Of Nichia/osram/seoul/philips/ Lumileds/cree/lednium/ Avago
make. The Product Should Be Bis Approved With R Number Mentioned On Product Label. To Be Supported With
product Test Reports - Lm79, Bis Report And Leds Test Reports. Luminaire Shall Be Conforming To Bis I.e. Is
10322 (part 5/sec 5) And Shall Be Complete With All Necessary Accessories Required For Proper Working Of Fixture
including Weather Proof Connection Cables, Water Proof Connectors Etc. As Required. This Includes Crane Charges
if Any For Height Work. (warranty Period Of 5 Years). All Test Reports And Technical Data Sheets To Be Submitted To
the Competent Authority For Approval. After Installation, Assembling And Commissioning Contractor Should Ensure
that All Parts Of The Light Are Properly Fixed And Put It Into Running Condition. The Entire Work Should Be Carried Out
as Per The Instructions Of Site Engineer. Testing Of The Fixtures To Be Done In The Presence Of Site Engineer For A
minimum Period Of 1 Week.
Closing Date12 Feb 2024
Tender Amount₹ 23.4 Lac
Karnataka Power Corporation Limited - KPCL Tender
Bengaluru Urban, Karnataka
Details: All The Extinguishers Shall Be Kept In Healthy Working Condition.check And Inspect The Condition / Operational Readiness Of Fire Extinguishers.check And Inspect Expiry Date On Fire Extinguishers.empty Cylinders And Expired Cylinders Shall Be Segregated And Listed For Refilling.carry Out The Refilling Works Of Co2,mechanical Foam,water Co2 And Abc Fire Extinguishers For Those Cylinders Which Are Empty And Crossed Expiry Date With Approval From Enginer In-charge And All Refilling Works Of Mechanical Foam,water Co2 And Dcp Shall Be Carried Out At Bhadra Generating Station Itself. Refilling Of Co2 And Abc Fire Extinguishers Shall Be Carried Out At Firm Works And Refilled Cylinders Shall Be Brought Back And Installed Within 07 Days.all Defective And Damaged Parts / Spares Of The Fire Extinguishers Shall Be Listed And Submitted. Such Damaged Parts / Spares Shall Be Supplied And Replaced With Approval From Engineer In-charge Within Reasonable Time. Check / Inspect And List Out Defective Fire Extinguishers And Issue Condemnation Certificate.carryout The Pressure Testing Of Water Co2, Mechanical Foam, Dcp, Abc And Co2 Type Fire Extinguishers Once In The Contract Period.carry Out Quarterly Over All Supervision And Maintenance Of The Fire Extinguishers System In A Year And Label The Cylinders For Healthiness And Next Due Date Of Maintenance. Water Proof Labels / Covers Shall Be Used For Outdoor Fire Extinguishers. Refilling / Recharging Shall Be Carried Out Using Quality Materials Only. The Spare For Fire Extinguishers Parts Shall Be Supplied By Kpcl.there Are 06 Fire Hydrant Points At Left Bank Power House And 02 Fire Hydrant Points At Right Bank Power House Of Bhadra Generating Station.carry Out Quarterly Over All Supervision And Maintenance Of The Fire Hydrant Systems In A Year And Report Shall Be Submitted For Healthiness Of The System. Carry Out Checks Of All The Fire Hydrants For Its Operational Readiness.checking Of Pipelines, Valves, Nozzles, Hoses, Hose Reel Drums And Couplings For Healthy Condition. Any Abnormalities In The System Shall Be Rectified With Approval From Engineer In-charge.the Firm Has To Conduct Fire Fighting Training In Theory, Practical And Panic Mock Drill Once In A Year. The Training Program Shall Be Conducted At Bhadra Generating Station. Time And Date Of The Training Program Shall Be Decided And Intimated By Engineer In-charge.
Closing Date31 Jul 2024
Tender Amount₹ 1.5 Lac
Southern Railway - SR Tender
Goods
Electrical Goods and Equipments...+1Electrical and Electronics
Ireps
Salem, Tamil Nadu
Details: Description:- Supply, Installation, Testing, And Commissioning Of Exterior Bis Registered 24w 24v Dc Rgbw
linear Led Wall Washer Luminaire For Facade Lighting With Extruded Aluminum Housing, Powder-coated Finish, And
clear Toughened Glass. With All Leds On, Minimum System Lumen Efficacy Equal To Or Greater Than 62.9 Lm/w.
the Luminaire Shall Be Capable Of Producing Dynamic Color-changing Light With 16 Million Colors As The Light Fixture
should Be Programmable Using 8-bit Control Dmx512 Protocol / Ethernet Based Control. Luminaire Should Be
complete With A Dedicated Lens Made Up Of Ul/vde Approved Pc For Each Led, Offering Beam Angle Of Different
types Such As Narrow, Medium, Wide Or Elliptical As Per The Site Requirement. The Fixture Should Be Erected With
the Necessary Required Brackets And Should Have Constant Locking Hinges For Simple Position Control From Various
angles Without Special Tools. Fixture Shall Be Suitable To Operate At An Ambient Temperature Range Of -30°c To
50°c And Complete Luminaire Shall Be Ip66 And Ik07 Rated. Led Life Time Shall Be At Least L70@ 25c @ 50000
burning Hours At 25°c. Led Should Be Of Nichia/osram/seoul/philips/ Lumileds/cree/lednium/ Avago
make. The Product Should Be Bis Approved With R Number Mentioned On Product Label. To Be Supported With
product Test Reports - Lm79, Bis Report And Leds Test Reports. Luminaire Shall Be Conforming To Bis I.e. Is
10322 (part 5/sec 5) And Shall Be Complete With All Necessary Accessories Required For Proper Working Of Fixture
including Weather Proof Connection Cables, Water Proof Connectors Etc. As Required. This Includes Crane Charges
if Any For Height Work. (warranty Period Of 5 Years). All Test Reports And Technical Data Sheets To Be Submitted To
the Competent Authority For Approval. After Installation, Assembling And Commissioning Contractor Should Ensure
that All Parts Of The Light Are Properly Fixed And Put It Into Running Condition. The Entire Work Should Be Carried Out
as Per The Instructions Of Site Engineer. Testing Of The Fixtures To Be Done In The Presence Of Site Engineer For A
minimum Period Of 1 Week.
Closing Date12 Feb 2024
Tender Amount₹ 38.8 Lac
Southern Railway - SR Tender
Goods
Paints and Enamels...+2Electrical Goods and Equipments, Electrical and Electronics
Ireps
Tirupathur, Tamil Nadu
Details: Description:- Supply, Installation, Testing, And Commissioning Of Exterior Bis Registered 24w 24v Dc Rgbw
linear Led Wall Washer Luminaire For Facade Lighting With Extruded Aluminum Housing, Powder-coated Finish, And
clear Toughened Glass. With All Leds On, Minimum System Lumen Efficacy Equal To Or Greater Than 62.9 Lm/w.the
luminaire Shall Be Capable Of Producing Dynamic Color-changing Light With 16 Million Colors As The Light Fixture
should Be Programmable Using 8-bit Control Dmx512 Protocol / Ethernet Based Control. Luminaire Should Be
complete With A Dedicated Lens Made Up Of Ul/vde Approved Pc For Each Led, Offering Beam Angle Of Different
types Such As Narrow, Medium, Wide Or Elliptical As Per The Site Requirement. The Fixture Should Be Erected With
the Necessary Required Brackets And Should Have Constant Locking Hinges For Simple Position Control From Various
angles Without Special Tools. Fixture Shall Be Suitable To Operate At An Ambient Temperature Range Of -30°c To
50°c And Complete Luminaire Shall Be Ip66 And Ik07 Rated. Led Life Time Shall Be At Least L70@ 25c @ 50000
burninghoursat25°c.ledshouldbeofnichia/osram/seoul/philips/ Lumileds /cree /lednium /
avago Make. The Product Should Be Bis Approved With R Number Mentioned On Product Label. To Be Supported
with Product Test Reports - Lm79, Bis Report And Leds Test Reports. Luminaire Shall Be Conforming To Bis I.e. Is
10322 (part 5/sec 5) And Shall Be Complete With All Necessary Accessories Required For Proper Working Of Fixture
including Weather Proof Connection Cables, Water Proof Connectors Etc. As Required. This Includes Crane Charges
if Any For Height Work. (warranty Period Of 5 Years). All Test Reports And Technical Data Sheets To Be Submitted To
the Competent Authority For Approval. After Installation, Assembling And Commissioning Contractor Should Ensure
that All Parts Of The Light Are Properly Fixed And Put It Into Running Condition. The Entire Work Should Be Carried Out
as Per The Instructions Of Site Engineer. Testing Of The Fixtures To Be Done In The Presence Of Site Engineer For A
minimum Period Of 1 Week
Closing Date10 Jul 2024
Tender Amount₹ 21.4 Lac
Tata Capital Housing Finance Limited - TCHFL Tender
Auction
Real Estate Service
Bengaluru, Karnataka
Details: Schedule 'a' Property All That Piece And Parcel Of Amalgamated Property Bearing No. 205/187, {(1). Site No. 5, Later Numbered As No. 190, New No. 208/190, (2). Site No. 6, Later Numbered As No. 188, New No. 206/188, (3). Site No. 13, Later Numbered As No. 187, New No. 205/187 And (4). Site No. 14, Later Numbered As No. 189, New No. 207/189, Each Measuring East To West: 40-0 Feet, North To South: 60-0 Feet) Formed Out Converted Land Bearing Sy. No. 94/2, Which Has Been Converted From Agricultural To Non-agricultural Residential Purposes, Vide Official Memorandum Bearing Order No. Bdis.aln.sr(n)67/2002-03, Dated 29.01.2003, Issued By Special Commissioner (revenue), Bangalore District, Bangalore, Situated At Mallathahalli Village, Yeshwanthapura Hobli, Bangalore North Taluk, Bangalore, Rajarajeshwari Nagarasabhe Ward No. 11, Bangalore-560 098, And The Aforesaid Amalgamated Property Now Comes Under The Purview, Jurisdiction, Management Of Bruhat Bangalore Mahanagara Palike, Rajarajeshwarinagar Sub Range, And It Has Assigned The Said Property As No. 205/94/2, Bbmp Katha Sl. No. 205, Mallathahalli, Bangalore, In The Corresponding Bbmp Ward No. 129-jnanabharathi, Totally Measuring 9600 Sq. Ft., And Bounded As Follows: East By: Site No.4 & Site No. 15, West By: Site No.7 & Site No. 12, North By: 40-0 Feet Road, South By: 50-0 Feet Road, Schedule 'b' Property Share Corresponding To 330 Sq. Ft., Of Undivided Right, Title And Interest In The Schedule 'a' Property To Be Conveyed To The Purchaser Herein. Schedule 'c' Property Apartment Bearing Flat No. 105 In The Ground Floor, Measuring About 1209 Sq. Ft. Super-built Area And Containing 2 Bed Rooms, Together With One Covered Car Parking Slot, Including Proportionate Undivided Share In Common Areas Such As Passages, Lobbies, Staircase Contained In The Apartment Building Known As 'maruthi Enclave". The Constructed Residential Flat Is Built Up With Bricks, R.c.c Roofed, Polished Teak Wood Doors For Main Door And Pooja Room, Remaining Doors Made Out Sal Wood Frames With Water Proof Flush Shutters, Anodised Aluminium / Upvc Windows & Ventilators And Flooring Is Of Vitrified And Ceramic, Having Water Electricity And Sewerage Facilities. Sale Of Property By Tata Capital Housing Finance Ltd., Bengaluru V/s. Shinde Raosaheb Uttam
Closing Date21 May 2024
Tender Amount₹ 60.4 Lac
Indian Army Tender
Goods
GEM
Corrigendum : Corrigendum Added
South Goa, Goa
Description: CATEGORY: Tape coloured half inchX65 Mtr long red blue geen , Scale
steel 36 inch long superior quality , Scale steel 12 inch long
superior quality , Toilet brush with handle best quality ,
Mouse Pad best quality , File Binder Cover with hard
cardboard Superior quality , Wall clock best quality as per
office ajanta quartz , Brown register cover big size ,
Scrubber scrotch brite , OEM Cartridge CWC 1020NW , Car
Diary as per sample , KM Card as per sample , Log Book as
per sample , Gate Pass Book 100 Pages Serialy Numbered
in Triplicate copies as per sample , Complaint Slip Book 200
pages as per sample , Tea cup set with saucer Set of 6 , Full
Plate Set Set of 6 , Harpic toilet cleaner , Dettol Liquid 1 Ltr
Good Quality , Sutli Good Quality , 3 in 1 Dustproof printed
combo for 16 inch desktop PC Monitor CPU and Keyboard
Cover set of 3 , Printer Cover , Dustproof Cover for
Photocopier Machine , Colin Glass Cleaner , Phenyle 1 Ltr
Good Quality , Hand Wash Liquid Good Quality , Mop with
Handle Good Quality , Plastic Bucket 30 Ltr Good Quality ,
Rubber Gloves Good Quality , Trash Can , Magnifying Glass ,
Table Top Cloth 5 feet x 4 feet Green Colour Good Quality ,
Borosil 350ml Set of 6 pcs Radius Vision Transparent
Drinking Glass Borosilicate Glass Tumblers for Water Cold
Drinks Juice Flame Proof , Water Bottle Milton 1 Ltr Steel ,
Rain Umbrella Full Size Good Quality , White Envelop for DO
Letter , Name Plate as per Sample , Adm Approval Register
300 Pages 42cm width and 30cm long as per Sample , SAI
PRASEEDA 48 X 36 Inch 4 X 3 Feet PVC Anti Skid Mat Foot
Mat Door Mat for Home Entrance Floor Mat Kitchen Office
Balcony Bath room Bed room Mat GREY Color ASM41 , Wash
and Wax car shampoo bright and lasting 1000ml Make
Carsun or equivalent , Unit Distribution Ledger IAFW-1814
100 Pages as per sample , Main Distribution Ledger 100
Pages as per sample , IAFW 2305 USR Book 100 Pages
Serially Numbered in Duplicate Copies as per Sample
Closing Date11 Oct 2024
Tender AmountRefer Documents
4291-4300 of 4308 archived Tenders