Veer Chandra Singh Garhwali Government Institute Of Medical Science And Research Tender
View complete overview of Uttarakhand VGIMS Tender
Veer Chandra Singh Garhwali Government Institute Of Medical Science And Research - VGIMS Tender
Eprocure
Opening Date25 Jul 2018
Closing Date8 Aug 2018
Tender Amount₹ 1,00,00,000
Costs
EMD
₹ 2,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_VGIMS_12526_1Bid Award Id
ViewTender No
MCS/Equipt/2018-18/1381Tender Authority
Veer Chandra Singh Garhwali Government Institute Of Medical Science And Research ViewPurchaser Address
-Website
http://https://vcsgsrinagar.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Biological safety cabinet with recommendable application in biosafety level 2 and 3, size/width 5-foot, Exterior dimensions: W x H x D (inch) 63.0 x 62.4 x 31.5, Interior dimensions: W x H x D (inch) 59.1 x 30.7 x 24.8, with All metal plenums, Aerosol-tight sealing front window, Real-time monitoring of HEPA flter efficiency- H14 HEPA EN 1822, 99.995% MPPS (SmartFlow indicator / PER factor), Timed UV system for long bulb life, Real-time airow alarms to notify user of impaired safety, Automatic airow balancing for safety in between certifcations (SmartFlow).
1
-
-
Table top Micro centrifuge with 12-place rotor Compact centrifuge with extremely small footprint Instrument should be capable to accommodate 12 x 1.5/2ml tubes The maximum speed should be 14100 x g (14500 rpm) Timer range 15 s to 99 min. with continuous mode Rotor and rotor lids should be made of aluminium Rotors and rotor lids should be autoclavable (121°C for 20 mins) There should be a dedicated soft spin key for brief spin The lid should automatically open at the end of the run Rotor and lid should be chemically resistant Instrument should have an air flow which minimizes sample heating Should have the possibility to add a rotor for PCR strips Should have very minimal acceleration and deceleration times Noise levels should be 52 dBA Instrument should possess European CE certification/ US FDA and also have an IVD Conformity.
1
-
-
Micropipette, Adjustable volume, fully autoclavable Spring Loaded Tip Cone for connecting tips very tightly Adjustment opening for adjusting pipettes to a specific liquid and volume. Control Button with very low operating force, Color indication for pipette volume. Tip ejector with very low operating force, positioned for perfect ergonomics. Volume Display: 4 Digits with magnifier. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material Very easy removable lower part for cleaning pipette Fully Autoclavable No discoloration upon UV irradiation 3 Years Warranty Volume Range -100– 1000 µl (with appropriate TIPS with autoclavable TIPS box)
1
-
-
Micropipette, Adjustable volume, fully autoclavable, Spring Loaded Tip Cone for connecting tips very tightly Adjustment opening for adjusting pipettes to a specific liquid and volume. Control Button with very low operating force, Color indication for pipette volume. Tip ejector with very low operating force, positioned for perfect ergonomics. Volume Display: 4 Digits with magnifier. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material Very easy removable lower part for cleaning pipette Fully Autoclavable No discoloration upon UV irradiation 3 Years Warranty Volume Range -10 – 100 µl (with appropriate TIPS with autoclavable TIPS box).
1
-
-
Micropipette, Adjustable volume, fully autoclavable, Spring Loaded Tip Cone for connecting tips very tightly Adjustment opening for adjusting pipettes to a specific liquid and volume. Control Button with very low operating force, Color indication for pipette volume. Tip ejector with very low operating force, positioned for perfect ergonomics. Volume Display: 4 Digits with magnifier.To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material,Very easy removable lower part for cleaning pipette Fully Autoclavable No discoloration upon UV irradiation 3 Years Warranty Volume Range- 0.5 – 10 µl, (with appropriate TIPS with autoclavable TIPS box).
1
-
-
Micropipette, Adjustable volume, fully autoclavable Spring Loaded Tip Cone for connecting tips very tightly Adjustment opening for adjusting pipettes to a specific liquid and volume. Control Button with very low operating force, Color indication for pipette volume. Tip ejector with very low operating force, positioned for perfect ergonomics. Volume Display: 4 Digits with magnifier. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material Very easy removable lower part for cleaning pipette Fully Autoclavable No discoloration upon UV irradiation 3 Years Warranty Volume Range - 500 – 5,000 µl (with appropriate TIPS with autoclavable TIPS box).
1
-
-
Micropipette, Adjustable volume, fully autoclavable Spring Loaded Tip Cone for connecting tips very tightly Adjustment opening for adjusting pipettes to a specific liquid and volume. Control Button with very low operating force, Color indication for pipette volume. Tip ejector with very low operating force, positioned for perfect ergonomics. Volume Display: 4 Digits with magnifier. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material Very easy removable lower part for cleaning pipette Fully Autoclavable No discoloration upon UV irradiation 3 Years Warranty Volume Range – 20 – 200 µl (with appropriate TIPS with autoclavable TIPS box)
1
-
-
Microscope Trinocular with observation methods: Bright field, simple polarization, uorescence, phase contrast, dark field. With Optical System: UIS2 (universal infi nity-corrected) optical system. Illumination System: Built-in transmited illumination system, Köhler illumination, LED power consumption 2.4 W (nominal value), precentered. Observation tube type: Trinocular (anti-fungal). Objectives: 2X, 4X, 10X, 20X, 40X, 60X, 100XO, 100XOI. Eyepiece: 10X Field No. 20.
1
-
-
pH meter, digital.
1
-
-
Weighing balance, digital, readability 0.1mg-220g.
1
-
-
Water bath, digital, 14 litre capacity, interior dimensions; WxDxH (mm) 400x245x145, Exterior dimensions; WxDxH (mm) 485x440x255, Power req 230 V / 50...60 Hz / 1.5 kW. Temperature regulation: Microprocessor-controlled Temperature constancy: ±0.1 °C temporal Temperature range: approx. 5 °C above ambient temperature to +99.9 °C with water level regulator 1919: approx. 3 °C above tap water temperature to +99.9 °C Over-temperature cut-out: electronic, 4 °C above set temperature and electromechanical 130 °C. Temperature display and setting digitally via LED display, in 0.1 °C increments. Fast and exact setting,exact reproducibility of the set value. Electronic monitoring of the temperature regulator. In case of failure, the cause of the fault is shown on the display. Soft-touch keys with clear symbols. Two-finger operation prevents unintentional alterations of the set value. Interior (bath interior and heating element, cover frame, lid and perforated floor) made of stainless steel. Standard equipment: lid and perforated floor.
1
-
-
Anaerobic system Jar, 3.5 litre, Transparent walls, unbreakable polycarbonate with study aluminium lid clamp and sealing ring, including accessories; stainless steel petriplate holder for 10 petriplates.
1
-
-
UV/VIS Spectrophotometer for measuring volumes from 1.5 µL to 4.5 mL Spectrometer to perform UV/Vis spectrometric and scan applications allowing quantification of sample volumes from 1.5 µL to 4.5 mL System have Preprogrammed methods for rapid and reliable analysis of Nucleic acids and proteins, OD600, dye methods (parallel measurement of biomolecule and dye label), FOI (frequency of incorporation) calculation. Should allow measuring and recording of UV/Vis spectral wavelengths from 200 to 830 nm, with smallest increment of 1 nm Should allow extinction measurement for one or several wavelengths Recording of wavelength scans should be possible with Integrated data processing Should have in-built methods with analysis via factor, standard or standard series Should allow performing Dual-wavelength method with subtraction and division analysis Should have data evaluation methods for concentration via standard series (Regression: linear, cubical, Quadratic) and (Interpolations: linear and Spline) Should have SpectraZoom® technology to analyze and process curve sections in detail view directly on the instrument display and for peak detection Should have the combination of Absorption single-beam spectrophotometer with reference beam as measuring principle with Xenon flash lamp as light source and beam receiver as CMOS photodiode array Should allow direct operation on the device and must not require PC to operate Data transfer of measured data to a PC by connecting the device directly to a PC should be possible without any additional software or should be through USB stick Should have facility for saving 1,000 measured results and 100 new methods in the instrument directly 1000 Nos. of disposable cuvettes should be supplied.Optional: BioCommand SFI data logging software Optional: System should be quoted with 15 racks made of anodized aluminium and Polypropeline made boxes with dividers for full capacity of Freezer.
1
-
-
Ultra-low temperature Freezer (-86 °C), Upright model, 410 Liters capacity Upright ultra-low freezer with Internal Dimension of H x W x D) 126-130 H x 54-58 x 57-60.cm. and external dimension of 190-195 x 80-84 x 85-87 cm. Freezer should be of 400 Liters and more capacity System should have Programmable operating temperature from –50°C up to –86°C with 1°C increment Fully programmable microprocessor controlled with membrane keypad and eye level control panel. Construction should be of Polyurethane foam (130mm thick) insulation. System should be made up of 18 gauge Steel, 1.2 mm thick with powder coated paint to resist scratch and rust and the interior should be Polished with 304 SS for easy cleaning and to eliminates potential for oxidation. Inner door should have silicone seal to prevent temperature loss and Outer door should have safe silicone triple point seal Freezer should have 5 Compartment with five inner doors. Ambient to -85 C pull down timing should be 5.3 hrs Freezer should have the sample (2” vials) capacity of 24,000 or more. Freezers should have heated air vent and front panel air filter. Should have security keyed locks on the outer doors and lids keep out unauthorized users Freezer must have battery back-up and 4 PIN security lock for unauthorized tampering. Freezer must have RS 485 interface data logging port and it must also have on board SMART PLUS diagnostic software. Freezer must have five compartments with five inner doors for easy handling of samples. Audible and visible alarms for temperature, power failure, system failure, battery low etc. and it also have remote alarm port for connection to an auto dialer. Freezer must use CFC-FREE, HCFC-FREE nonflammable refrigerants, and refrigeration system must be energy efficient and hermetically sealed two stage cascade refrigeration system. Compressor should be capable to run any voltage between 210 – 250V. Freezer must have ISO 9001 standard quality test requirements and IEC 61010 Electrical safety CE & UL certified. Freezer should have efficient power consumption in the range of 10 to 11 kWh/day Freezer must have capacity to hold 15 racks and 240 boxes of 2” height vials Freezer should have electric supply of 230v/50hz, 10 amps. Single phase Freezer should be supplied with 5KVA voltage stabilizer. Optional: Back Up for Co2 and LN2 are available.
1
-
-
-40 ̊C deep freezer, (vertical) with suitable electronic stabilizer. Temperature range: -20/-10 ̊C to -40 ̊C. Noise level (dB): 43. LED display, microprocessor controller, Power supply: 220-240 Volts/50Hz. Capacity (L/Cu.Ft): 188/6.6. Interior Dimensions D x W x H (inch): 15 x 16.5 x 48.2. Exterior Dimensions D x W x H (inch): 23.5 x 24 x 58.1. Drawers: 7.
1
-
-
Electrophoretic assemblies, for mini gel: 14x12cm gel size, horizontal for Nucleic acid identifications, with power supply, gel casting tray and Teflon combs.
1
-
-
UV gel trans illuminator system with safety goggles and shield
1
-
-
3 – in - 1 mixer to perform mixing of tubes (0.2ml, 0.5ml, 1.5ml, 2ml), plates (96 and 384 well SBS standard MTP, DWP and PCR Plates) , and vortexing Mixing speed ranging from 300-3000rpm Vortex mixing in touch, set speed and continuous modes should be possible Specifically designed to take care of cross contamination without spilling or lid wetting while low volume samples are mixed. Should have preprogrammed methods for commonly used tubes and plate formats Automatic imbalance detection is a must System should be stable on work bench even at the maximum speed with minimum noise levels Instrument must have CE Certification
1
-
-
CO2 incubator should have 170-190 Ltr. Capacity. System should be Direct heat with six-sided heating with fan-less design for gentle convection circulation to provide stable temperature control or Air Jackated CO2 Incubator, System should have Temperature control from 4 ° C above ambient to 50°C, with control accuracy ±0.1°C., excellent uniformity and rapid recovery with no over shoot. It should have CO2 control range from 0.2 to 20% with control accuracy and uniformity of ±0.1% and should have rapid recovery of at least 0.7% per minutes. It must have Infra-red (IR) CO2 sensor with programmable auto-zero function to provide superior accuracy & stability. Its auto-zero function automatically adjust IR Sensor baseline for optimum accuracy & operational security. No need for manual measurement or operator’s intervention. It should come with minimum 3 adjustable height shelves & humidity reservoir (removable) to achieve at least 95% RH. It should have independent door heater to eliminate condensation on inner doors surface. It should have HEPA filter on CO2 inlet. It should have high heat decontamination in system temperature up to 120° or 180°C. During sterilization the system should operate without removing HEPA filter and CO2 sensor. It should have ISO 9001 & European CE/FDA Certification. Seamless Electro-polished finished drawn inner chamber (shiny quality finish) made of medical grade stainless steel or of copper. CO2 cylinders with regulator (ISI Mark) to be supplied with the main machine. Warranty 1 Year.
1
-
-
Hot air oven, temperature range 50 ̊C to 250 ̊C, chamber volume 419L, chamber dimensions D x W x H (inch): 23 x 21 x 51, exterior dimensions D x W x H (inch): 30 x 31 x 66, temperature uniformity ±3 ̊C, stability ±0.5 ̊C
1
-
-
Magnetic stirrer with stirring bars and temperature control; Dimension: 5x8mm, 6x18mm, 6x30mm, 9x40mm, 9x50mm, 9x75mm.
1
-
-
Tissue homogenizer, for soft tissue grinding, Stirring capacity 50ml/15ml/1.5 ml centrifuge tubes, Nucleic acid/ Protein extraction purpose.
1
-
-
Micropestle, Teflon, for manual grinding of soft tissues in microcentrifuge (1.5 ml) tubes, Nucleic acid/ Protein extraction purpose.
1
-
-
BOD incubator, Large capacity, Temperature range: Ambient +5 °C to 75 °C. Temperature uniformity/stability: ± 0.5 °C / ± 0.4 °C. Chamber dimensions D x W x H (inch): 22 x 21 x 51. Exterior dimensions D x W x H (inch): 30 x 31 x 66. Shelves Supplied/Max (Max. Load) 2 / 39 (30kg / 66lb).