Power Transmission Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand PTCUL Tender
Power Transmission Corporation Of Uttarakhand Limited - PTCUL Tender
Electrical and Electronics
Eprocure
Opening Date2 Feb 2024
Closing Date5 Mar 2024
Tender Amount₹ 8,46,600
Costs
EMD
₹ 25,500Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PTCUX_68864_1Bid Award Id
ViewTender No
T-14/SE(OandM)R/2023-24Tender Authority
Power Transmission Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
(iv) Overhauling of mechanism 220 kV Isolator with cubicle including cleaning, lubrication and proper alignment.
8
-
-
... More
(v) Cleaning of equipments porcelain/polycon (i.e.CB/CT/CVT/LA/Isolator/ BPI) with clean cotton cloth complete
170
-
-
... More
(vi) Replacement of Conductor Jumpers/Runner/Dropper etc. including connectors/clamps, cutting /drilling of holes in clamps
8
-
-
... More
(vii) Replacement of 220 kV Terminal Connector/Clamp/Jaw/Blade etc. & tightening related equipment (including replacement of minor conductor segment/patch)
16
-
-
... More
(viii) Replacement of 220 kV Take-Off Assembly/ Moving Head Assembly/ Rotary Head Devive etc (including proper alignment) complete
4
-
-
... More
(ix) Unforeseen Work /Maintenance of equipments/Panels etc. including tracing of fault & remidial action as per direction of concerning site engineer.
12
-
-
... More
(x)) Topping up of SF-6 Gas in 220 kV Circuit Breakers/oil in CT & CVT under breakdown /preventive maintenance (including shifting of gas cylinder/ oil drums)
4
-
-
... More
(xi) Repairing of HPSV Lamp fittings/replacement of LED fittings at 220 kV Switchyard.
40
-
-
... More
(B) 132KV Switch Yard:
(i) Tightening of 132 kV Bay Equipments (CB, Line Isolator, Transfer Isolator, CT, CVT and LA including all connectors of droppers/runner/jumpers)
32
-
-
... More
(ii) Cleaning of 132 kV Circuit Breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work.
40
-
-
... More
(iii) Overhauling of mechanism 132 kV Isolator with cubicle including cleaning, lubrication and proper alignment.
8
-
-
... More
(iv) Cleaning of equipments porcelain/ polycon (i.e.CB/CT/CVT/LA/ Isolator/BPI) with clean cotton cloth complete.
170
-
-
... More
(v) Replacement of Conductor Jumpers/Runner/Dropper etc. including connectors/clamps, cutting /drilling of holes in clamps
8
-
-
... More
(vi) Replacement of 132 kV Terminal Connector/ Clamp/Jaw/ Blade etc. & tightening related equipment (including replacement of minor conductor segment/patch)
16
-
-
... More
(vii) Replacement of 132 kV Take-Off Assembly/ Moving Head Assembly/Rotary Head Devive etc (including proper alignment) complete
4
-
-
... More
(viii) Unforeseen Work /Maintenance of equipments/Panels etc. including tracing of fault & remedial action as per direction of concerning site engineer.
12
-
-
... More
(ix) Topping up of SF-6 Gas in 132 kV Circuit Breakers/oil in CT & CVT under breakdown /preventive maintenance (including shifting of gas cylinder/ oil drums)
10
-
-
... More
(x) Repairing of HPSV Lamp fittings/replacement of LED fittings at 132 kV switchyard.
40
-
-
... More
(C) 33KV Switch Yard:
(i) Tightening of 33 kV Bay Equipments (CB, Bus & Line Isolator, CT including all connectors of droppers/runner/jumpers)
52
-
-
... More
(ii) Cleaning of 40 MVA Transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete.
8
-
-
... More
(iii) Cleaning of 33 kV Circuit Breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work.
52
-
-
... More
(iv) Overhauling of mechanism 33 kV Isolator with cubicle including cleaning, lubrication and proper alignment.
26
-
-
... More
(v) Cleaning of equipment's porcelain/ polycon (i.e.CB/CT/CVT/LA/ Isolator/BPI) with clean cotton cloth complete
150
-
-
... More
(vi) Replacement of Conductor Jumpers/ Runner/ Dropper etc. including connectors/clamps, cutting /drilling of holes in clamps
65
-
-
... More
(vii) Replacement of 33 kV Terminal Connector/Clamp/Jaw/Blade etc. & tightening related equipment (including replacement of minor conductor segment/patch)
65
-
-
... More
(viii) Unforeseen Work /Maintenance of equipments/Panels etc. including tracing of fault & remedial action as per direction of concerning site engineer.
12
-
-
... More
(ix) Topping up of SF-6 Gas in 33 kV Circuit Breakers/oil in CT & CVT under breakdown /preventive maintenance (including shifting of gas cylinder/ oil drums)
10
-
-
... More
(x) Repairing of HPSV Lamp fittings/replacement of LED fittings etc. at 33 kV switchyard
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements