Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date10 Jan 2025
Closing Date31 Jan 2025
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692599_1Bid Award Id
ViewTender No
89109/24-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F 0.63mm thick plain galvanised MS sheeting using grade-O sheets with 120gm Zinc (Spelter) coating Per Sqm both sides inclusives, as in roof, ridges, hips, valley gutters, drip and straight flashing complete all as specified and directed.
30
-
-
... More
M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
60
-
-
... More
S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa (AZ 150) as in roof covering / cladding to wall , fixed with self tapping screwcomplete all as specified and directed.
120
-
-
... More
S&F Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall , fixed with self tapping screwcomplete all as specified and directed.
40
-
-
... More
M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
2
-
-
... More
Dismantling of boarding any description and fixed in any position with nails complete all as specified and directed.
15
-
-
... More
S&F 20mm thick 2nd class soft wood (Chir) boarding planned one side fixed with butt joints with nails in any situation/position except flooring and skirting complete all as specified and directed.
15
-
-
... More
Dismantling of ceiling board (flbre pulp, insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets complete all as specified and directed.
250
-
-
... More
S&F of 4 mm thick E-Board Classic (Make-Everest) for insulation and accoustic purpose, 595 x 595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface complete all as specified and directed.
250
-
-
... More
S&F of GI powder coated grid frame work for false celling comprising of the following sections for making partitions of 600x600 mm size fixed to walls with rawl plugs & screws and hanged to roof with and including 4mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 28mmx24mmx0.3mm thick, cross tee shall be 28mmx24mmx0.3mm thick and wall angle shall be 24mmx24mmx0.3 mm thick complete all as specified and directed.
250
-
-
... More
Demolition of brick work or stone masonry precast PCC block walling built in cement mortar complete all as specified and directed.
3
-
-
... More
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 complete all as specified and directed.
3
-
-
... More
Taking down cement or cement lime plaster of any description on brick or PCC blocks or stone wall or concrete surface etc including racking out joints, hacking for keys, scrubbing down with water etccomplete all as specified and directed.
1000
-
-
... More
M&L for rendering 15 mm thick readymade plaster on inner/outer walls by adding 17-19% of potable water by weight of material for thickness above 15mm it is recommended to be applied in multiple layers. ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 days 10-12 Mpa/Bulk density 1500-1600 Kg/m3. (Note : The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 Mtr ht complete all as specified and directed. Make Fosroc/ Sika/ Ultrarech/ Choksey
1000
-
-
... More
M&L for preparation of New plastered surfaces & applying a layer of 3mm thick Birla putty on wall surfaces including cornics etc for proper levelling of plaster and two coat of oil emulision distemper complete all as specified and directed.
400
-
-
... More
M&L for complete removal of existing treatment for preparing old painted surfacess and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed.
400
-
-
... More
M&L for preparation of newly plastered surfce of ceiling & applying three coats of white wash complete all as specified and directed.
100
-
-
... More
Material & Labour for applying Two or more coats of 100% remium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed.
500
-
-
... More
M&L for complete removal of existing treatment and applying Two or more coats of 100% remium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed.
550
-
-
... More
M & L for painting to new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
100
-
-
... More
M & L for painting to old steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coats of synthetic enamel paint including preparation of surfaces complete all as specified and directed.
300
-
-
... More
Taking up or down 15mm dia steel tubing and connections by disconnecting fittings/tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
30
-
-
... More
Taking up or down 20mm dia steel tubing and connections by disconnecting fittings/tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
30
-
-
... More
S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees, short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
20
-
-
... More
Fixing only GI water tubing of 15mm dia ,medium grade conforming to IS-1239 (Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
10
-
-
... More
S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
25
-
-
... More
Fixing only GI water tubing of 20 mm dia ,medium grade conforming to IS-1239 (Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
5
-
-
... More
S&F 15mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15mm bore dia of pipe complete all as specified and directed.
3
-
-
... More
S&F 20mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20mm bore dia of pipe complete all as specified and directed.
3
-
-
... More
Dismantling of reinforced cement concrete of any description and any position not otherwise specifically provided for complete all as specified and directed.
2
-
-
... More
Dismantling water tanks exc 250ltrs but not exc 500 ltrs capacity complete all as specified and directed.
3
-
-
... More
Dismantling water tanks of any description, capacity exceeding 500 litres but not exceeding1000 liters complete all as specified and directed.
3
-
-
... More
S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
3
-
-
... More
S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
3
-
-
... More
S&F in repair 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium road & high density plastic ball screwed for iron pipe and fixed in repairs (min weight 210 gm) complete all as specified and directed.
4
-
-
... More
S&F in repair 15 mm dia ball valves high pressure of PTMT with epoxy coated aluminium road & high density plastic ball screwed for iron pipe and fixed in repairs (min weight 210 gm) complete all as specified and directed.
4
-
-
... More
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall and in floors complete all as specified and directed.
20
-
-
... More
S&F of 75 mm bore PVC (SWR) pipe single socketed in as length with rubber ring as in vent pipe complete all as specified and directed
30
-
-
... More
S&F in repairs of 110 mm dia PVC (SWR) bend complete all as specified and directed.
10
-
-
... More
S&F in repairs of 75 mm dia PVC (SWR) bend complete all as specified and directed.
5
-
-
... More
M&L for PVC (SWR) floor trap 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed.
12
-
-
... More
M&L for roof surface must be pressure-washed with water with, is to be used to and/ or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution. 2 tiles joint repair all visible and joint more than 0.50mm and not giving hollow sound, on the tiles roof or at the junctions of flat roof & vertical parapet wall, pipe joints, should be cut and widen v shape with mechanical cutter in the size (6mm W x 6mm D) and fill with Dr. Fixit PMM methodology.Glass fiber apply Dr Fixit URP or Primeseal A on the well prepared groove, allow to cure tack free. Followed by filling all the joints covering the entire area uniformly with suitable chemical. Allow chemical to cure a minimum 24 hours. Apply minimum 50mm-100mm width 45 GMS glass Fibre mesh/ non-woven geo testile fleece with the coat of Dr Fixit Roofseal classic along the length of crack when the 1st coat is still in wet condition. Apply the second coat with an interval if 4-6 hours. Waterproofing: Apply a coat of Dr Fixit Roofseal classic (diluted with water in the ratio 2:1) as Self Priming 14.0-18.0 Sq. mt/litre.Allow coating to dry for 3-4 hours. Applt two coats of Dr Fixit Roofseal classic/litre/coat, without, the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total of DFT of microns. Allow the system to air cure for 5 days minimum. Check to see no void surface is left untreated/uncoated. The material having following technical specification as per ASTM D 6083 M- type II, Attains a Tensile strength of 2.5 N/mm2 confirming to ASTM D 2370: Elongation at break 300% confirming ASTM D 2370, Adhesion to Concrete 2.0N/mm2 Confirming ASTM D 4541 and crack bridging ability up to 2mm, air cure the coating for 7 days before water pound test for 48 Hrs. The system comes with 7 year waterproofing warranty from service provider. For vertical surface : Apply 2 coat of Dr Fixit Roofseal classic with forced coverage of /litre/coat. Entire terrace should be coated with roofseal classic alongwith parapet walls needs to be enveloped with roofseal classic/Raincoat system. The total 3 coats treatment inclu taking down/dismantling of old tarfelt/old unserviceable roof treatment from RCC roof by scrapping, broomig and washing with water etc . Make : Dr Fixit or equivalent (Note : The treatment should be carried out through authorised applicator only)
1000
-
-