Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Sep 2024
Closing Date1 Oct 2024
Tender Amount₹ 43,10,000
Costs
EMD
₹ 86,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670925_1Bid Award Id
ViewTender No
86434/RWL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
HT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for 63 to 200 KVA Transformer.
6
-
-
HT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for 300 to 315 KVA Transformer.
2
-
-
LT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for 63 to 200 KVA Transformer.
11
-
-
LT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for 300 to 315 KVA Transformer.
2
-
-
Disconnecting all incoming and outgoing cables, removing the transformer and LT Panel from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to Giraffe park and placing new plinth and connect HT cable of panel complete all as specified and directed.
1
-
-
M & L for build platform of size 2.5m × 2.5m ×1.5 m high (outer dimension) built with 150 mm thick PCC (1:5:10) type E 2 foundation 150mm on both sides of walll, 350 mm thick of brick masonary built in CM (1:6 ), 450 mm below GL & 950 mm above GL duly plastered in CM (1:4) on exposed faces & finishing in same mortar as the work proceeds in faces in contact with with soil/floor of 50 mm PCC 1:2:4 type B-1 laid in bays over 100 mm thick hardcore over approved earh filling complete all as specified and directed.
1
-
-
M&L mild steel work as in Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410-0 or Fe-310-0,de E-165, complete all as specified and directed.
127.66
-
-
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
41.65
-
-
Fixing only chain link fencing 4mm dia galvanised steel wire,100x100mm mesh, made up into mattresses or cages, lapped,wired and laid/ fixed in position,including line wires, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete as specified and directed.
45
-
-
M&L for Filtration/ dehydration and cleaning of transformer oil off line by dehydration plant , including testing of samples before and after dehydration and filtration, dielectric strength should not less than 55 KV at 2.5 mm gap after dehydration/filtration all as specified and directed. Note:- (i)For running of filtration plant the arrangement of electric supply / DG set should be made by contractor and the cost of same deemed to be included in quoted rate. (ii) Transformer are installed at various locations of Raiwala Military camp and GRTU area, i.e pole mounted, plinth based, indoor type. (iii) No online dehydration allowed. (iv) Before dehydration the contractor should open the Transformer and replace the Gaskets, Low Tension bushings ,High tension bushings , silica gel breather, Thermometer, drain valve etc if found defective as per direction of Engr-in-Charge. The materials replaced by the contractor except rubber gasket remaining materials are paid as S & F item of Boq. The rubber gasket paid as supply only item rate.
4125
-
-
Supply and topping up of insulating transformer oil confirming to IS 335 1993 for distribution transformer with dielctric strength not less than 60 KV complete all as specified and directed.Note:- (i)For running of filtration plant the arrangement of electric supply / DG set should be made by contractor and the cost of same deemed to be include in quoted rate. (ii) Transformer are installed at various locations of Raiwala Military camp and GRTU area, i.e pole mounted, plinth based, indoor type
300
-
-
Supply only rubber gasket of 3 mm thickness suitable for Tranformer of outdoor /Indoor type as per IS specifications and directed by Engr-in-Charge.
20
-
-
M&L for rewinding of Transformer of capacity 100 KVA to 315 KVA winding the defective coils with approved quality of copper wire as per IS specification of existing guage and with new insulation materials, bracings the terminals before placing into the transformer and assembling the HT coil with new insulation between core all as required and fitting the coils in the chamber, testing and commissioning the Transformer after providing necessary connections complete including trasportation to workshop and back to site, lowering the Transformer from two pole structure and after repair locate the Transformer in two pole structure including in the quoted rate.
-
-
-
HT Winding
200
-
-
LT Winding
300
-
-
S&F Rectangle size (15 x 10x .5 cm) SS316 Name plate of thickness 5 mm, should Engraving the details of Step down Transformer Make in Top, Capacity in KVA, Amperes, Phases, Maker's SL No, Date of purchase and miscellaneous details provided by department for engraving the plate after engraving the complete details fixing the plate on existing Transformer.
6
-
-
Supply only transformer off load tap changer suitable upto 315 KVA transformers 11 KV/433 volts including removing the existing u/s one complete all as specified. Make :-Jaipuriya Brothers/Crompton/GEC/BHEL/ATLAS
1
-
-
Supply only dial type thermometer of 150 mm dia with max temp indicator complete with resetting device and alarm contacts etc complete all as specified & directed.
2
-
-
M&L for detect HT 11 KV cable fault of 24 hrs x 7 days i.e entire contract period with technician around the clock on Raiwala Military cannt areas detect the cable fault and necessary excavation of soil and refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, and charging of HT cable all as specified and directed by Engr-in-Charge. (Note: (i) Cable joint required size measured and paid separately (ii) Each job considered cable fault locator use in one day in any length of cable )
2
-
-
S&F cable jointing kit 11 KV (Earthed) grade cable for outdoor straight through Cold shrinkable type joint complete with jointing material and accessories suitable for 95 Sqmm, 3 core XLPE armoured aluminum conductor cable complete all as specfied and directed.
5
-
-
M&L for preparation of old painted surfaces above ground level steel tubular pole 11 to 9 M long, cleaning by scraping and applying and two coats of aluminium paint over one coat of red oxide primer complete including cross arms, brackets, clamps, terminal boxex etc and writing pole number in black paint (Size shall be 50 mm) complete all as directed by Engineer - In - Charge . (Note: The quoted rate inclusive of two coats of white wash on exposed coping surface and painting yellow and black strips in alternate layers with synthetic enamel paint up to1Mtr height above coping of pole as directed).
10
-
-
M&L for preparation of old painted surface complete of 11 Mtr long 2 pole structure cleaning by scraping and applying and two coats of aluminium paint over one coat of red oxide primer on cross arms, brackets, clamps etc and writing pole No in Black & white paint (Number size shall be 50 mm ) as specificed and as directed by Engineer in charge. (Note: The quoted rate inclusive of two coats of white wash on exposed coping surface and painting Yellow and black strips in alternate layers with synthetic enamel paint up to1Mtr height above coping of pole as directed).
2
-
-
Excavation in trenches in any type of soil and n. Exc 1.5 M wide and n exc 1.5 m in depth for poles, laying under ground HT cable, GI tubing (where provided for protection of cables), stay and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
341.55
-
-
Returning, filling in any type of soil including spreading, levelling and well ramming in layers not exc 25 cm thick, in any type of soil complete all as specified and directed.
233.18
-
-
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
108.7
-
-
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note: Punned (consolidated) thickness of sand will be measured and paid.
72.09
-
-
M&L for PCC (1:2:4), type B-1 (using 20 mm graded mechanically curushed stone agreegate) for coping of pole and foundation for fencing post etc including necessary form work, finished the exposed surface fai with out using extra cement including necessary form work complete all as specified and directed.
0.63
-
-
M&L for cutting of road /hard standing as required at site, not exceeding 20 cm width and not exceeding 60 cm in depth for laying of cable protection pipe including insert the cable inside pipe making good the disturbed road/hard standing by providing PCC (1:2:4) Type B-1 up to the existing surface level and make good complete all as directed.
20
-
-
Taking up or down steel water tubing (GI Pipe) and connections of any dia bore complete all as directed.
45
-
-
S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :-
Note :- 80mm and 100mm bore pipe will be jointed by welding as directed at site
-
-
-
50mm bore
9
-
-
80mm bore
36
-
-
M&L for un-reinforced precast concrete cable cover ISI marked, class HV, Type-I flat of size 300 mm x 180 mm x 40 mm as cable protection over sand cushioning perpendicular across the cable length wise in trenches complete all as specified and directed.
3654
-
-
M&L for un-reinforced precast concrete cable cover ISI marked, class LV, Type-I flat of size 250 mm × 150 mm × 40 mm as cable protection over sand cushioning perpendicular across the cable length wise in trenches complete all as specified and directed.
894
-
-
Taking down unserviceable cable of any size and description all as directed and specified.
165
-
-
S&F/Laying, connecting and testing of HT cable XLPE insulated screened PVC badded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 11KV (Earthed) as per IS 7098 (Part-II) with stranded aluminium conductor of following size complete all as specified and directed:-
Note:- (i) The earth work, GI pipe shall be measured and paid sepretely.
(ii) Cable may fixing/ passing through pipe laid in trenches or fixed to pole/ wall or fixed to LT panel etc.
(iii) ACSR conductor & cross arms, UG Cables replaced with UG Cable. (iv) While fixing GI pipe with pole suitable size of 'D' clamps should be provided by contractor. The MS work for the same shall be measured and paid separately.
-
-
-
95 Sqmm ,3 core
420
-
-
120 Sqmm, 3 core
362
-
-
Supply and laying , fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, insulated, armoured heavy duty electric cable with aluminium conductor, XLPE , 1100 volts grade, cross-sectional area of size 240 Sqmm 3.5 core with all as specified and directed. by Engr-in-charge.
85
-
-
Supply and laying , fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, insulated, armoured heavy duty electric cable with aluminium conductor, XLPE , 1100 volts grade, cross-sectional area of size 50 Sqmm sqmm 2 core with all as specified and directed. by Engr-in-charge.
80
-
-
M&L for cable jointing kit suitable for 11 KV (E) grade cable indoor end termination, cold shrinkable type joint complete with joining material and accessories suitable for 95 sqmm XLPE 3 Core HT cable armoured aluminium conductor cable join on existing or new cable removing burnt existing termination of Transformer, panel etc all as specified and directed.
1
-
-
M&L for cable jointing kit suitable for 11 KV (E) grade cable for outdoor end termination, cold shrinkable type joint complete with jointing material and accessories suitable for 95 Sqmm XLPE 3 core HT cable armoured aluminum conductor cable in join in existing outdoor termination on HT pole, Transformer after completion of cable joint positioning the HT cable as per direction of Engr-in-Chage.
12
-
-
Supply only silica gel breather container with silica gel for the following sizes of Transformer:-
-
-
-
63 KVA
1
-
-
100 KVA
2
-
-
200 KVA
12
-
-
300 to 315 KVA
2
-
-
Supply, installation, testing of 11 KV outdoor type gang operated triple pole air break switch suitable for vertical mounting fixed type complete with 12 insulators 400 amps rating before instalation merge the insulators in water and meggaring the insulators, for testing 11000 volt meggar provided by contractor and steel frame mechanically operated mechanism consisting of operating rod 25 mm bore medium grade GI pipe of suitable length worked form ground level and with locking arrangement flat iron clamp 50 mm x 6 mm size including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers as in repair complete all as specifed and directed.
10
-
-
Supply, installation, testing and commissioning of lightning arrester expulsion type, distribution class with all fittings arrangements suitable to 11000 volts grade and discharge capacity 12 KV /65 KA complete all as specified and directed.
21
-
-
Dismantling of old unserviceable/defective (Pin type, disc type) insulators of any size/type and removing materials from site of work complete all as directed
8
-
-
M&L for pin type, porcelain, vitreous, white brown or green insulator 11000 volts grade of size 150 mm height, 150 mm dia, including galivanized mild steel spindle with two galvanized iron washers and one galvanized nut bolt complete all as specifed and directed.
5
-
-
M&L for disc type insulator, procelain vitreous, 145 mm high and 255 mm dia ball and socket type, white or brown or green, single disc assembly for tension wtih tension clmps for conductors, working pressure 11000 volts complete all as specified and directed.
3
-
-
M&L for preparation of old painted surface complete of 11 Mtr long 4 pole structure cleaning by scraping and applying and two coats of aluminium paint over one coat of red oxide primer on cross arms, brackets, clamps etc and writing pole No iN
Black & white paint (Number size shall be 50 mm ) as specificed and as directed by Engineer in charge. (Note: The quoted rate inclusive of two coats of white wash on exposed coping surface and painting Yellow and black strips in alternate layers with synthetic enamel paint up to1Mtr height above coping of pole as directed).The pole painting is done for HT pole inside raiwala cantt and HT line going for Lower pump house.
5
-
-
Dismantling of old cross-arms of mild steel channel or angle sections, etc, including mild steel bolts, nuts, washers, etc. and removing from site of work complete all as directed.
3
-
-
M&L for Cross arms, bracings, suupports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directd and incusive of one primer coat, one under coate and one finishing coate of panint all as specifed and directed by Engr-in-Charge.
1.65
-
-
Dismantling of ACSR conductor of any type and removing from site of work complete all as directed.
3
-
-
M & L for prunning of tree branches touching the overhead HT lines, poles and 2/4 poles structures complete to trim the three meter radius of over head line the required cleaning tools and plants carried by the contractor at site. If found any tree growth in HT pole sturctures remove the tree complete including roots of tree growth and make the surface good. (Note: (i)Any breakdwon of line caused during pruning shall be made good by the contractor without any extra cost . (ii) distance between pole to pole shall be measured as one span.
18
-
-
M&L for Earthing complete with galvanized mild steel earth plate (electrode) 600 x 600 x 6.00mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32x6 mm GI strip earthlead welded and riveted to earth plate at one end and connected to main switch / control switch of the building at another end GI earth strip encased in and including 40 mm dia GI light grade pipe and 20 mm dia GI 'meadium grade' pipe as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4type B-1 duly reinforced with MS TMT bars 8 mm dia @ 150 c/c both ways and with 10 mm dia MS bar in lifting handle , excavation , earth work including laying the GI pipe concealed in floor / wall all as described in electrical plate No 3 of MES SSR part-I
15
-
-
M&L for earthing with galvanished steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 3.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia GI wire & PVC insulated solid copper coductor of size 4 mm by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover, 20 mm dia (MG) GI watering pipe with funnel wire mesh and protectin pipe of GI of suitable size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 5 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution board and all as directed. Note: Rate for achieving required depth by compressor machine if required is deemed included in tem unit rate.
42
-
-
M&L for Earth continuity conductor or main earthing lead fixed to recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised ironl wire connecting on pole earthing all as specified and directed by Engr-in-charge.
80
-
-
M&L for Earth continuity conductor or mainearthing lead fixed to recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm GI strip connecting on earthing all as specified and directed by Engr-in-charge.
20
-
-
M&L for replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 11000V, 25x20cm size
60
-
-
S&F in repair anti climbing devices, spike type, fabricated out of MS bar (round, square or flat) including nuts bolts washers and welding in two halves made of shape to suit the cross section of pole complete as specified and as directed.
0.1
-
-
Dismantling and taking out of old existing GOD 12 insulators type on four pole structure and refixing the same GOD set on new location inside Raiwala Military camp complete all as specified and as directed.
2
-
-
M&L for cable jointing kit suitable for 11 KV (E) grade cable for straight through joint , cold shrinkable type joint complete with jointing material and accessories suitable for 120 Sqmm XLPE 3 core HT cable armoured aluminum conductor cable in join in existing outdoor termination on HT pole, Transformer after completion of cable joint positioning the HT cable as per direction of Engr-in-Chage.
2
-
-
Labour only for restringing of HT overhead line ACSR conductor of any type and size on pole after disconnecting all jumper connection & binding of insulators and including rejointing all connections and insulators, jumper binding with aluminium conductor complete all as specified and directed.
620
-
-
Prepration of old surface of distribution transformer 11KV/433V for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of tranformer complete all as specified and directed by Engr-in Charge of following capacity of Transformer: Note:-Write MES No on the transformer in white paint and size of letter shall be all as directed by Engineer-in-Ckarge. (ii) Clean the transformer manufacture plate with thinner and while painting, hide the manufacture plate with stickers all as directed
-
-
-
63 KVA to 100 KVA
3
-
-
200 KVA to 315 KVA
16
-
-