Uttar Pradesh State Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh State Industrial Development Authority - UPSIDA Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date7 Mar 2024
Closing Date27 Mar 2024
Tender Amount₹ 22,64,742 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
12 m - 15 m Span Over Head Structure with 300 dia M S two vertical post Supply , fixing & eraction of built up Overhead Structure of 12M - 15M span comprising of two vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom . The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant . The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1 : 3 : 6 ( cement coarse sand and 40 mm gauge stone ballast and RCC M - 25 cement concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering . The lateral vertical clearances and complete . Installation work shall be as per relevant clauses of MORT & H specification section 800 and IRC 67 2012 complete in all respect . The Rates shall include cost of design , fabrication , supply , transportations , Local shifting Erection of Signage structure using crane , Inclusive of all taxes etc. all T & P machine , material and labour required for proper completion of work as per direction of Engineer - in - charge . Rates as per SOR 2022 Ghaziabad SI No. 22.08 New Item

2

464444

232222

... More
Reflective Raised Pavement Markers ( Cat Eye / Road Stud ) Supply and fixing of raised pavement marker with Made of Plastic body of g RPM / Road Stud shall be moulded from ASA ( Acrylic Styrene Acrylonitrite ) ar HIPS ( High - Imoact Polystyrene ) or Acryloniitrite Butadien Styrene ( ABS ) or Any other suitable material approved by the Engineer . The Marker shall support a load of 13,635 kg tested in accordance with ASTM D4280.The Reflective panels shall consist of number of lenses containing single or dual prismnalic cubes capable of providing total internal reflection of the light entring the lens face . Lenses shall be mouled of methyl methecrylate conformning to ASTM D788 of equivalent . The slop or retro - reflecting surface shall preferably be 35 +/- 5 degree to base and the area of each retro - reflecting surface shall not be less than 13.00 sq.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & amp ; Width shall not exceed 130 mm . The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name , trade or other means of identification of the manufacture . epoxy installations , excess adhesive around the edge of the marker , excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed . The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro - reflectance of the reflecting panel , to the Engineer . In addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers . In case the markers are displaced , damaged , get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer , at his own cost . The rate shall include all materials , labour , T & amp ; P , transportation , installation and incidentals all complete as per direction of the Engineer - in - Charge. As per SI No. 22.05 New Item Safety Items. SOR Ghaziabad -2022

1156

374544

324

... More
Retro - ReflectiveSheeting type - IV with 4 mm thick ACM Double Side : Providing & fixing of reflective signs with a corrosion resistant 4 mm thick with 0.4 to 0.5 mm both side aluminium skin aluminium composite panel face to be fully covered with High Intensity prismatic sheeting type NV as per IRC - 67 : 2012 retro reflective sheeting with back frame MS angle of 35x35x5 mm . Legends letters , numerals and borders etc should be as per MoRTH specification No 801.3.7 .The sheeting shall have a pressure sensitive adhesive of the aggressive tack type requiring no heat , solvent other preparation for adhesion to a smooth clean surface , in a manner recommended by the sheeting manufacturer . The ACM ( Aluminium Composite Materials ) shall be fixed on the Back frame MS Angle with riveting . Micro prismatic type IV Retro reflective sheeting confirming to ASTM D4956-09 shall be Pressure fixed . The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection , daytime colour and luminance , shrinkage , flexibility , liner removal , adhesion , impact resistance , specular gloss and fungus resistance , 3 years outdoor weathering and its having passed these tests shall be oblained from International / Government Laboratory / Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition , it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad . Alternatively , a certificate conforming to ASTM Specification ( D 4956-09 ) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally . In such a situation , the Employer / Client , if so desires , could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 : 2012 & Proof of the same Report shall be uploaded which quoting tender . The rate shall include all materials , labour , T & P , transportation , installation and incidentals all complete as per direction of the Engineer - in - Charge . As per SI No. 22.13 New Item SOR Ghaziabad -2022.

66.24

507530

7662

... More
Providing and erecting work information board (S.S. Frame) Rates as per H.O. Letter No. 1150 dated 16.09.2022

1

42000

42000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.