Uttar Pradesh Projects Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Projects Corporation Limited - UPPCL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date15 Oct 2024
Closing Date25 Oct 2024
Tender Amount₹ 20,81,79,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation up to 1.50 mt.

239.49

123

29682.39

... More
Level 1.50 mt. to 3.0 mt. depth

79.83

212

16962.28

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

3639.31

489

1780059.31

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

63.45

4756

301798.66

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

73.66

1482

109231.15

... More
Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :

-

-

-

... More
Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

480.92

216

104114.37

... More
Treatment of masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 ce ment : 2 coarse sand) to the full depth of the hole,With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

480.92

30

14437.22

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

1.23

7000

8610.28

... More
Same as above for ground floor (Above Plinth level)

1.11

6751

7494.61

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab)

-

-

-

... More
Same as above for ground floor

59.51

6751

401805.57

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

82.18

7000

575278.9

... More
Same as above for ground floor (Above Plinth level)

19.13

6751

129163.85

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing)

93.01

7000

651091.39

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

44.54

7000

311790.24

... More
Same as above for ground floor (Above Plinth level)

14.52

6751

98037.59

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

31.89

4980

158815.07

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate12.5 mm nominal size).

42

286

12048.96

... More
Painting on D.P.C. with two coats of air blown bitumen VG-10 grade @ 1.7 kg/sqm approximate including cost of fuel if any.

42

102

4286.1

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

211.07

6358

1342031.61

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

22.79

642

14640.75

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

22.79

73

1667.77

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

392.86

7530

2958483.3

... More
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)

62.2

287

17882.5

... More
15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)

927.08

276

255920.43

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

668.22

239

160339.39

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

284.89

54

15594.88

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm

48.13

1084

52206.61

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

7.44

1133

8431.68

... More
Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm.

3.34

3586

11978.64

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : :25 mm thick

126.29

1360

171801.13

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete

35.34

1644

58104.97

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

54.63

765

41828.55

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

194.73

885

172404.21

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).

243.56

332

80983.7

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhat nosing.

-

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

68.4

98

6767.5

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding

191.03

152

29225.68

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

216.5

91

19811.92

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

-

-

-

... More
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

355.84

136

48500.99

... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm.

12.06

913

11017.53

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

-

-

-

... More
(a) Single leaf

25.2

2425

61125.62

... More
(b) Double leaf

3.15

2500

7875.38

... More
Fixing of Door/windows/ventilators chaukhats in position.

-

-

-

... More
Door chaukhats

15

190

2850

... More
Window chaukhats

4

142

570

... More
Ventilator chaukhats

4

95

380

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.

12.74

743

9470.79

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

92.34

539

49801.73

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat. (Inner side)

927.08

129

120177.38

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

381.24

119

45546.74

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat. (Ceiling)

408.7

129

52979.78

... More
Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work.

1717.03

108

187087.59

... More
Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm.

15

522

7837.5

... More
Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.

-

-

-

... More
(a) 250 mm x 10mm

15

418

6270

... More
(a) 200 mm x 10mm

15

285

4275

... More
Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm.

30

213

6412.5

... More
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

30

84

2548.2

... More
Providing and laying integral cement based water proofing treatment BRICK COBA including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.

-

-

-

... More
over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse

-

-

-

... More
sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120mm and minimum thickness at khurra as 65 mm.

113.7

1176

133741.9

... More
Making drain along with the apron. (Size - 150 X 150 MM).

79.46

1288

102357.99

... More
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.

7.65

7987

61105.91

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

29.75

47

1400.04

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

29.75

108

3238.59

... More
Wooden Painting:

-

-

-

... More
Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood.

56.7

52

2955.2

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

56.7

108

6172.36

... More
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. Red sand stone

379.19

893

338931.4

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) Red sand stone - Exposed face machine cut and table rubbed with rough backing. 30 mm thick

286.98

5247

1506045.21

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.

344.37

498

171782.09

... More
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type. Fastener with threaded dia 10 mm

71.74

27

2003.7

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work

224.08

356

79945.02

... More
Finishing walls with Silicon addetive paint on red sand stone of prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.

286.98

511

146675.48

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

76.64

273

20985.56

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick.

372.99

718

267836.66

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

908.26

587

533956.97

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

674.94

671

453039.98

... More
AMPHIETHEATER BUILDING (INTERNAL W/S & SANITATION WORKS)

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:

-

-

-

... More
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

2

4725

9450.68

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :

-

-

-

... More
W.C. pan with ISI marked white solid plastic seat and lid

7

4549

31846.36

... More
Providing & fixing toilet paper holder C.P. brass

7

561

3928.26

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

7

243

1706.53

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:

-

-

-

... More
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

9

1554

13990.95

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

9

722

6502.95

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

9

161

1457.64

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

9

77

700.38

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

9

1122

10104.75

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink)

-

-

-

... More
15 mm nominal bore

27

401

10827

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :

-

-

-

... More
45 cm length

-

-

-

... More
15 mm nominal bore

20

68

1365

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15mm nominal bore

9

353

3184.83

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.

-

-

-

... More
15mm nominal bore

6

557

3347.22

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

3

5571

16714.44

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade

1.24

2829

3508.21

... More
Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr) including all its accessories, complete in all respect including testing etc.

2

39301

78603

... More
Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc.

2

27806

55613

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
For Internal Toilet

-

-

-

... More
15 mm nominal outer dia Pipes

6.14

347

2134.2

... More
20 mm nominal outer dia Pipes

39.82

375

14947.63

... More
25 mm nominal outer dia Pipes

11

437

4817.78

... More
32 mm nominal outer dia Pipes

17.6

516

9085.47

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm nominal bore

29.92

233

6998.59

... More
32 mm nominal bore

29.92

362

10837.62

... More
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall

-

-

-

... More
Terrace loop & Tank Filling Pipe

-

-

-

... More
25 mm nominal bore

55

385

21187.1

... More
Providing , checking, storing, fixing in position of approved quality Screwed ends Brass float valve with brass ball float and PTFE seat suitable for Body test pressure of 15Kg/sqcm of the following sizes:

-

-

-

... More
25mm

3

1843

5529

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :

-

-

-

... More
25mm diameter pipe

55

21

1161.6

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :

-

-

-

... More
25 to 40 mm nominal bore

6

636

3820.38

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
For vertical pipe connection with terrace ringmain

-

-

-

... More
20 mm nominal bore

2

377

754.04

... More
25mm nominal bore

6

434

2607.54

... More
32mm nominal bore

2

481

963.02

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1500

7

11520

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
110 mm dia (for rain water)

36

263

9486.72

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single Push Fit Coupler

-

-

-

... More
110 mm dia

9.6

89

855.36

... More
Single tee with door

-

-

-

... More
110x110x110 mm

4

163

654

... More
Plain bend 87.5 deg

-

-

-

... More
110 mm dia

8

104

839.84

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
110 mm dia

14.4

259

3733.34

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

4

208

833

... More
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.

-

-

-

... More
Internal Toilet (Soil & Waste Pipe)

-

-

-

... More
75 mm

29.7

479

14248.58

... More
110 mm

41.25

679

28019.06

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
Bend without door (87.5°)

-

-

-

... More
110mm bend

9

247

2223

... More
Bend without door (45°)

-

-

-

... More
100mm

9

209

1881

... More
75mm

13

128

1667.25

... More
Y' Fitting without door

-

-

-

... More
100mm

9

394

3548.25

... More
75mm

13

218

2840.5

... More
Reduced 'Y' Fitting without door

-

-

-

... More
100mm x 75mm

1

318

318.25

... More
Single Tee without door

-

-

-

... More
110mm

9

346

3120.75

... More
75 mm

13

213

2778.75

... More
Single Tee with door

-

-

-

... More
110mm

9

403

3633.75

... More
Clean Out Plug (COP)

-

-

-

... More
110mm

6

190

1140

... More
75 mm

6

133

798

... More
Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.

-

-

-

... More
For Wash basin & Urinal

-

-

-

... More
50mm dia. Pipe

7.26

327

2379.47

... More
32mm dia. Pipe (for wash basin & sunken toilet spout)

25.08

175

4407.81

... More
Elbow (90°)

-

-

-

... More
50mm

3

80

242.25

... More
32mm

9

38

342

... More
Elbow (45°)

-

-

-

... More
50mm

1

66

66.5

... More
32mm

6

42

256.5

... More
T fitting

-

-

-

... More
50mm

3

95

285

... More
32mm

9

42

384.75

... More
Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm x 50mm/40mm (Toilet)

7

1159

8113

... More
Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm (Toilet)

6

1092

6555

... More
Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
Rectangular type with openable circular lid

-

-

-

... More
150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)

13

137

1787.76

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :

-

-

-

... More
150 x 100mm size P-type

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

7

1909

13364.12

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:

-

-

-

... More
100 mm diameter

21

309

6504.54

... More
Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.

-

-

-

... More
All kind of soil

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

12

245

2950.68

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:

-

-

-

... More
100mm dia SW pipe

12

673

8083.68

... More
AMPHIETHEATER BUILDING (INTERNAL ELECTRIFICATION WORKS)

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

69

1176

81182.64

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

415

186

77551.05

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

168

220

37054.08

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

792

267

212153.04

... More
4 x 10 sq.mm + 2 x 6 sq.mm. earth wire

156

806

125740.68

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.

7

382

2677.92

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

12

469

5639.76

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required

8

295

2367.52

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

12

32

384.96

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

23

69

1604.94

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

55

95

5249.2

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

8

176

1415.76

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep

6

360

2165.46

... More
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.

6

166

996.12

... More
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).

12

1510

18126

... More
Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.

22

1470

32353.2

... More
Supply of Surface mounting round 15 Watt to 18 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect

8

1629

13034

... More
Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required.

4

1589

6357.4

... More
Supplying of LED mirror light luminaire with 10W watt complete with electronic  ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor.

5

1068

5343.75

... More
Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,

4

5047

20189.4

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan

8

2189

17516.08

... More
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN

6

2280

13685.7

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 63 A,25KA,FP MCCB

1

9083

9083.9

... More
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double Door

1

1856

1856.67

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way Double door

1

3989

3989.24

... More
8 way Double door

1

4785

4785.64

... More
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door

1

6024

6024.76

... More
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required

-

-

-

... More
40 amps SP MCB

1

551

551

... More
40 amps DP MCB

1

1167

1167.55

... More
40 amps TP MCB

2

1840

3680.3

... More
40 amps 4P MCB

2

2429

4858.3

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amps

6

1626

9758.94

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

19

205

3901.08

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

19

10

198.17

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

1

215

215.74

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

1

5992

5992.68

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

45

115

5197.05

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

10

230

2301.8

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

30

195

5870.7

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm.

120

310

37245.6

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Up to 35 sq.mm.

10

29

296.7

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle

20

44

882.2

... More
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment

-

-

-

... More
3.5 x 25 sq.mm.

100

402

40280

... More
2 x 10 sq.mm,

50

235

11780

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
2 X 10 sq. mm (19mm)

2

193

386.58

... More
3½ X 25 sq. mm (28mm)

2

251

502.06

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100mm dia

5

530

2654.7

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)

5

232

1162.95

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness.

10

536

5365.5

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm wide x 50 mm depth x 1.6 mm thickness.

2

929

1859.08

... More
GUEST HOUSE (CIVIL WORKS UP TO PLINTH LEVEL)

-

-

-

... More
Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.

-

-

-

... More
Excavation up to 1.50 mt.

929.57

123

115210.91

... More
Level 1.50 mt. to 3.0 mt. depth

309.86

212

65839.05

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

7690.37

489

3761513.77

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)

145.74

4756

693209.4

... More
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.

145.51

1482

215778.23

... More
Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :

-

-

-

... More
Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

983.05

216

212820.49

... More
Treatment of masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 ce ment : 2 coarse sand) to the full depth of the hole,With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

983.05

30

29511.16

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Tie beam)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

199.8

6627

1324142.53

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing)Same as above for ground floor (Up to Plinth level)

274.32

6627

1818011.91

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column)Same as above for ground floor (Up to Plinth level)

101.62

6627

673470.29

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

20.4

4980

101593.84

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 13mm nominal size)

59.74

286

17138.21

... More
Painting on D.P.C. with two coat of air blown bitumen 80/50 @ about 1.7 kg/sqm including cost of fuel if any.

59.74

102

6096.47

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

670.29

7530

5047705.98

... More
15 mm thick plinth plaster [1 cement : 4 coarse sand]

80.83

287

23238.63

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

1178.08

273

322581.87

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

837.32

671

562034.3

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

1306.5

587

768078.29

... More
GUEST HOUSE (CIVIL WORKS ABOVE PLINTH LEVEL)

-

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel)

-

-

-

... More
Ground Floor

4

6751

27007.6

... More
First/Second Floor

7.2

6751

48613.68

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156]

-

-

-

... More
All works above plinth level - Slab

-

-

-

... More
Ground Floor

139.59

6751

942497.72

... More
First/Second Floor

217.01

6751

1465229.82

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156]

-

-

-

... More
All works above plinth level - Beam

-

-

-

... More
Ground Floor

67.34

6751

454672.95

... More
First/Second Floor

108

6751

729205.2

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156]

-

-

-

... More
All works above plinth level - Column

-

-

-

... More
Ground Floor

46

6751

310587.4

... More
First/Second Floor

74.01

6751

499708.12

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

-

-

-

... More
Ground Floor

149.44

6358

950173.89

... More
First/Second Floor

359.11

6358

2283303.98

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

-

-

-

... More
Ground Floor

152.34

642

97866.26

... More
First/Second Floor

239.48

642

153846.74

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

-

-

-

... More
Ground Floor

152.34

73

11148.24

... More
First/Second Floor

239.48

73

17525.15

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

-

-

-

... More
Ground Floor

310.28

7530

2336603.88

... More
First/Second Floor

493.64

7530

3717420.19

... More
15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)

-

-

-

... More
Ground Floor

1141.8

276

315193.89

... More
First/Second Floor

2336.77

276

645065.36

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

-

-

-

... More
Ground Floor

646.55

239

155139.67

... More
First/Second Floor

1552.02

239

372407.2

... More
Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

-

-

-

... More
Ground Floor

368.25

3586

1320699.17

... More
First/Second Floor

770.33

3586

2762726.92

... More
Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

-

-

-

... More
Ground Floor

71.03

3586

254743.41

... More
First/Second Floor

84.91

3586

304522.92

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work

253.98

356

90612.44

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm

-

-

-

... More
Ground Floor

153.92

1084

166957.02

... More
First/Second Floor

844.21

1084

915714.59

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

-

-

-

... More
Ground Floor

19.35

1133

21929.16

... More
First/Second Floor

73.58

1133

83387.48

... More
Laying of 25 mm thick Kota stone of size 45x45 cm and above flooring over previously prepared base with 2cm 1:3 cement & sand mortar including filling of joints with cement mixed with pigment required for matching the shade of floor as per direction of E/I including cutting polishing with wax polish including supply of all material T & P etc required for proper completion of the work.

-

-

-

... More
Ground Floor

37.5

1360

51013.88

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

-

-

-

... More
Ground Floor

63.98

765

48987.57

... More
First/Second Floor

110.06

765

84269.64

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

-

-

-

... More
Ground Floor

414.35

885

366844.77

... More
First/Second Floor

543.87

885

481515.3

... More
Providing and Fixing Knauf Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13/21mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual.

-

-

-

... More
The back of the perforated panel shall have sound absorbing non-woven acoustical fleece hot pressed to achieve NRC upto 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Knauf and approved by the Architect/ Engineer-in-Charge.

-

-

-

... More
The panel shall be mounted by tongue and groove mechanism using inside clip on Knauf aluminium extruded keel made of Grade 6063-T5 having dimensions 3000(L) x 24(H) x 15.5(W). The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m.

-

-

-

... More
To ensure specification of tiles, Manufacturers Test Certificate is required having complete site address & duly signed by Manufacturer.

285.75

8247

2356837.43

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).

119.44

332

39713.8

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

-

-

-

... More
(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf.

95.45

2425

231525.43

... More
(b) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Double leaf.

54.81

2500

137031.58

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

150.26

322

48509.94

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood

2.26

99814

225581.06

... More
Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin- charge.

123.75

533

66003.3

... More
Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm).

-

-

-

... More
Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer’s specification and direction of engineer-incharge.

39.38

3045

119942.42

... More
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4

-

-

-

... More
profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head,

-

-

-

... More
comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over

-

-

-

... More
backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.

-

-

-

... More
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.

-

-

-

... More
Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds

-

-

-

... More
Fixed window/ventialtors with mullion /transom.

-

-

-

... More
Using R3 series with frame (55 mm & above) x (45 mm & above) x mullion (55 mm & above) x (65 mm & above). (Height up to 2.5 mt.)

188.33

5465

1029360.93

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes

209.53

743

155762.51

... More
M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.

-

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding

317.93

152

48640.11

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work (Inner walls & Ceiling)

-

-

-

... More
Ground Floor

2084.29

129

270186.51

... More
First/Second Floor

3748.98

129

485980.28

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).

-

-

-

... More
Ground Floor

646.55

119

77243.33

... More
First/Second Floor

1552.02

119

185419.83

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (Inner & Ceiling surface)

-

-

-

... More
Ground Floor

2084.29

183

382321.31

... More
First/Second Floor

3748.98

183

687675.4

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

-

-

-

... More
Ground Floor

646.55

108

70448.09

... More
First/Second Floor

1552.02

108

169108.1

... More
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.

76

189

14405.04

... More
Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .

76

522

39710

... More
Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete

-

-

-

... More
(a) 250 mm x 10mm (For Door)

76

418

31768

... More
Providing and fixing stainless steel handles with screws etc. complete.

-

-

-

... More
(a) 125mm For Door Handle

152

213

32490

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.

-

-

-

... More
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to

-

-

-

... More
required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar

-

-

-

... More
of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge

1012.4

1176

1190855.75

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

21.2

47

997.67

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

21.2

108

2307.83

... More
Wooden Painting:

-

-

-

... More
Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood.

348

52

18137.76

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

348

108

37883.28

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.

31.55

1760

55545.04

... More
Providing & applying 100% solids, flexible, elastomeric, UV stable, 2 component, waterproof, fast setting, monolithic, hydrophobic in nature, NO-VOC, CFTRI-US-FDA-175-300 coating on prepared surface as following :- P/L DONCRETE/EQUIVALENTPP solvent free primer @ 100gsm per m2 forconjunction of DONCRETE/EQUIVALENT PU conforming to ASTM-D-2369 C,ASTM-D-2369, ASTM-D-638, ASTM-D-4541, ASTM-D- 638, ASTMD- 2240, ASTM-E-96, ASTM-B-117-73, ASTM-D-91, ASTM-D-624, ASTM-D-4060, ASTM-C-8, ASTM-D-512, ASTM-G-53, ASTM-3912 @ 1 Ltr per m2 for 1.00 mm thick. The coating shall be carried out in single application with multiple passes, using high pressure plural component reactor strictly as per manufacture specification, rate materials, labor, and tools. Surface preparation includes repairs of holes, cracks, voids, pinholes, bug holes. Joints shall be filled with epoxy putty Confirming the ASTM D 638, ASTMD 4541, and ASTM D 2369. The corner rounding/angle fillet shall be prepared/replaced as required to smooth transition of coating from horizontal to vertical surfaces.

151.93

902

137116.83

... More
20 mm cement plaster of mix Cement mortar 1:4. for protect of waterproofing area.

151.93

340

51706.34

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.

662.52

539

357316.91

... More
Providing and fixing stainless steel ( Grade 304) railing with toughened glass made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

21.93

1710

37500.3

... More
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

73.34

5501

403455.07

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment

11.7

978

11453.72

... More
Centering and shuttering including strutting, propping etc. and removal of form for:

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick.

2604.39

718

1870160.37

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

1255.83

587

738289.9

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

944.83

671

634198.24

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.

2865.46

289

828920.27

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:

-

-

-

... More
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:

-

-

-

... More
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry /structural steel frame work of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it water tight

-

-

-

... More
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.

-

-

-

... More
The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories

-

-

-

... More
1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”

-

-

-

... More
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

159.19

2451

390208.12

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.

-

-

-

... More
The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm

-

-

-

... More
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

159.19

2596

413349.57

... More
Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System with 15 mm thick Optra Microlook 90 Edge Tiles with Knauf Suprafine 15mm face exposed grid.

-

-

-

... More
The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, Light Reflectance ?88% as per ASTM E-1477, Colour Pebble White/Black, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 15mm Square Tegular/Microlook 90? edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%.

-

-

-

... More
SUSPENSION: The tile shall be laid on Knauf Suprafine 32 with 15 mm wide T - section flanges colour global white having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm (all sections). The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability.

-

-

-

... More
To ensure specification of tiles, Manufacturers Test Certificate is requiredhavingcomplete site address& duly signed by Manufacturer.

-

-

-

... More
INSTALLATION : To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Knauf suspension system (specifications above) at 1200mm maximum. The First/Last Knauf suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall.

-

-

-

... More
Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.

-

-

-

... More
Perimeter trim to be Knauf wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation should be carried out as per Knauf recommended procedure and designs approved by the Architect/ Engineer-in-Charge.

-

-

-

... More
KNAUF SUSPENSION SYSTEM - accessories supplied by Knauf consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).

373.61

2612

976056.13

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.

-

-

-

... More
iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)

46.94

537

25224.15

... More
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

19.67

270

5329

... More
GUEST HOUSE (INTERNAL W/S & SANITATION WORKS)

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :

25

4549

113737

... More
W.C. pan with ISI marked white solid plastic seat and lid

-

-

-

... More
Providing and fixing white vitreous china extended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete.

-

-

-

... More
Providing & fixing toilet paper holder C.P. brass

25

561

14029.5

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

25

243

6094.75

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:

-

-

-

... More
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

17

1554

26427.35

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-

-

-

-

... More
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

8

2765

22123.6

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

25

722

18063.75

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

25

161

4049

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

25

77

1945.5

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

25

1122

28068.75

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink)

-

-

-

... More
15 mm nominal bore

99

401

39699

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :

-

-

-

... More
45 cm length

-

-

-

... More
15 mm nominal bore

74

68

5050.5

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :

-

-

-

... More
100 mm diameter

8

135

1083.44

... More
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.

-

-

-

... More
15 mm nominal dia

8

4846

38771.04

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.

-

-

-

... More
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

8

495

3960.16

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required

-

-

-

... More
Kitchen sink with drain board

-

-

-

... More
510x1040 mm bowl depth 200 mm

2

4998

9997.54

... More
Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete

-

-

-

... More
Flexible Pipe

-

-

-

... More
32mm Dia

2

83

166.96

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15mm nominal bore

25

353

8846.75

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.

-

-

-

... More
15mm nominal bore

2

557

1115.74

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

12

5571

66857.76

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. White Agaria Marble StoneGranite Stone of approved shade

4.95

2829

14004.54

... More
Providing and fixing of storage type (pressurised type) electric hot water heater copper sheet container, 25 mm thick insulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters

8

12155

97242

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
For Internal Toilet

-

-

-

... More
15 mm nominal outer dia Pipes

58.19

347

20226.26

... More
20 mm nominal outer dia Pipes

238.48

375

89520.62

... More
25 mm nominal outer dia Pipes

29.7

437

13008.01

... More
32 mm nominal bore

44

516

22713.68

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm nominal bore

162.84

233

38089.9

... More
25 mm nominal bore

26.22

280

7351.56

... More
32 mm nominal bore

64.86

362

23493.59

... More
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall

-

-

-

... More
Terrace loop & Tank Filling Pipe

-

-

-

... More
40 mm nominal bore

55

566

31180.05

... More
50 mm nominal bore

55

732

40260.55

... More
Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:-

-

-

-

... More
Lehry Make Automatic OHT Level Control System Consist of Following Items

-

-

-

... More
1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch.40mm

1

43956

43956.5

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :

-

-

-

... More
40mm diameter pipe

55

29

1637.9

... More
50mm diameter pipe

55

35

1958.55

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
For vertical pipe connection with terrace ringmain

-

-

-

... More
20 mm nominal bore

11

377

4147.22

... More
25mm nominal bore

2

434

869.18

... More
32mm nominal bore

4

481

1926.04

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

10000

7

76800

... More
Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks.

-

-

-

... More
25mm dia.

12

1225

14706

... More
40mm dia.

1

1368

1368

... More
50mm dia.

8

1515

12122

... More
65mm dia.

3

1657

4973.25

... More
80mm dia.

3

1914

5742.75

... More
100mm dia.

2

2398

4797.5

... More
150mm dia.

5

3439

17195

... More
200mm dia.

1

4826

4826

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm dia (for rain water)

187

263

49278.24

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single Push Fit Coupler

-

-

-

... More
110 mm dia

61.6

89

5488.56

... More
Single tee with door

-

-

-

... More
110x110x110 mm

11

163

1798.5

... More
Plain bend 87.5 deg

-

-

-

... More
110 mm dia

22

104

2309.56

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia

74.8

259

19392.65

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

11

208

2290.75

... More
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.

-

-

-

... More
Internal Toilet (Soil & Waste Pipe)

-

-

-

... More
75 mm

143

479

68604.25

... More
110 mm

123.09

679

83608.88

... More
Exposed on Wall (Soil & Waste Pipe)

-

-

-

... More
110 mm

215.25

679

146208.56

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
Bend without door (87.5°)

-

-

-

... More
110mm bend

33

247

8151

... More
Bend without door (45°)

-

-

-

... More
100mm

25

209

5225

... More
75mm

51

128

6540.75

... More
Y' Fitting without door

-

-

-

... More
100mm

25

394

9856.25

... More
75mm

51

218

11143.5

... More
Reduced 'Y' Fitting without door

-

-

-

... More
100mm x 75mm

4

318

1273

... More
Single Tee without door

-

-

-

... More
110mm

25

346

8668.75

... More
75 mm

51

213

10901.25

... More
Single Tee with door

-

-

-

... More
110mm

15

403

6056.25

... More
Reduced Tee with door

-

-

-

... More
110mm x 75mm

15

351

5272.5

... More
Coupler

-

-

-

... More
110mm

56

209

11704

... More
Clean Out Plug (COP)

-

-

-

... More
110mm

4

190

760

... More
75 mm

4

133

532

... More
Vent Cowl

-

-

-

... More
110mm

10

85

855

... More
Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.

-

-

-

... More
For Wash basin & Urinal

-

-

-

... More
50mm dia. Pipe

29.04

327

9517.86

... More
32mm dia. Pipe (for wash basin & sunken toilet spout)

173.2

175

30439.9

... More
Elbow (90°)

-

-

-

... More
50mm

12

80

969

... More
32mm

25

38

950

... More
Elbow (45°)

-

-

-

... More
50mm

4

66

266

... More
32mm

15

42

641.25

... More
T fitting

-

-

-

... More
50mm

12

95

1140

... More
32mm

25

42

1068.75

... More
Coupler

-

-

-

... More
32mm

28

33

931

... More
Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm x 50mm/40mm (Toilet)

19

1159

22021

... More
Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm (Toilet)

32

1092

34960

... More
110mm x 75mm (Kitchen)

2

1092

2185

... More
Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
Rectangular type with openable circular lid

-

-

-

... More
150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)

57

137

7838.64

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

8

1909

15273.28

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter

16

309

4955.84

... More
Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

138

245

33932.82

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:

138

673

92962.32

... More
GUEST HOUSE (INTERNAL ELECTRIFICATION WORKS)

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

506

1176

595339.36

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

3940

186

736267.8

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

168

220

37054.08

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

4752

267

1272918.24

... More
2 X 6 sq. mm + 1 X 4 sq. mm earth wire

1518

352

534472.62

... More
4 x 10 sq.mm + 2 x 6 sq.mm. earth wire

780

806

628703.4

... More
4 x 16 sq.mm + 2 x 6 sq.mm. earth wire

216

1094

236468.16

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.

141

382

53940.96

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

72

469

33838.56

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

23

583

13410.61

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required

104

295

30777.76

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

84

32

2694.72

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

68

69

4745.04

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

381

95

36362.64

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

104

176

18404.88

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required

-

-

-

... More
Upto 450 mm sweep

20

360

7218.2

... More
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.

20

166

3320.4

... More
Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.

131

5299

694182.1

... More
Supply of Recessed mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.

81

5034

407758.05

... More
Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 42W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor

12

3418

41017.2

... More
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).

12

1510

18126

... More
Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.

43

1470

63235.8

... More
Supply of Surface mounting round 15 Watt to 18 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect

39

1629

63540.75

... More
Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required.

20

1589

31787

... More
Supplying of LED mirror light luminaire with 10W watt complete with electronic  ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor.

24

1068

25650

... More
Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,

4

5047

20189.4

... More
Supplying of 9 Watt Decorative LED Wall Light complete in all respect.

15

1827

27417

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan

104

2189

227709.04

... More
Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fan complete in all respect.

1

3334

3334.5

... More
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN

20

2280

45619

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required

-

-

-

... More
63 A,25KA,FP MCCB

3

9083

27251.7

... More
100 A,30KA,FPMCCB

3

6193

18581.97

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way Double door

8

3989

31913.92

... More
8 way Double door

6

4785

28713.84

... More
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door

6

6024

36148.56

... More
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required

-

-

-

... More
40 amps TP MCB

10

1840

18401.5

... More
63 amps TP MCB

3

1924

5774.1

... More
40 amps 4P MCB

10

2429

24291.5

... More
63 amps 4P MCB

3

2525

7575.3

... More
100 amps 4P MCB

1

9218

9218.8

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.

-

-

-

... More
25 amps

30

1626

48794.7

... More
40 amps

9

2118

19070.37

... More
63 amps

3

2183

6549.27

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

135

205

27718.2

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

69

10

719.67

... More
Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround

-

-

-

... More
the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.

-

-

-

... More
The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.

-

-

-

... More
The minimum clearances between bus bars shall be as follows :

-

-

-

... More
Phase to phase - minimum 20mm

-

-

-

... More
Phase to neutral-minimum 15mm

-

-

-

... More
GUEST HOUSE PANEL

-

-

-

... More
INCOMING

-

-

-

... More
1No. Of 400 Amps FP MCCB of 35KA breaking capacity

-

-

-

... More
Metering :

-

-

-

... More
1 Set of CT's one of 400/ 5Amp ratio for Multifunction Meter

-

-

-

... More
One (1) Set of Phase Indication Lamp.

-

-

-

... More
BUS BAR

-

-

-

... More
1 Set of 500 Amps TPN Aluminium Bus Bars

-

-

-

... More
OUTCOMING

-

-

-

... More
250 Amps FP MCCB of 25KA - 1 No

-

-

-

... More
125 Amps FP MCCB of 25KA - 1 No

-

-

-

... More
100 Amps FP MCCB of 25KA - 6 No

-

-

-

... More
80 Amps FP MCCB of 25KA - 1 No

-

-

-

... More
63 Amps FP MCCB of 25KA - 3 No

-

-

-

... More
40 Amps FP MCCB of 25KA - 1 No

-

-

-

... More
SPARE & SPACE- 1 No

-

-

-

... More
Panel described as above

1

276882

276882.25

... More
ELEVATOR PANEL

-

-

-

... More
INCOMING

-

-

-

... More
1No. Of 80 Amps FP MCCB of 25KA breaking capacity

-

-

-

... More
Metering :

-

-

-

... More
1 Set of CT's one of 80/ 5Amp ratio for Multifunction Meter

-

-

-

... More
One (1) Set of Phase Indication Lamp.

-

-

-

... More
BUS BAR

-

-

-

... More
1 Set of 100 Amps TPN Aluminium Bus Bars

-

-

-

... More
OUTCOMING

-

-

-

... More
63 Amps 4P MCCB of 25KA - 2 No

-

-

-

... More
63 Amps DP MCB of 10KA - 2 No

-

-

-

... More
SPARE & SPACE- 1 No

-

-

-

... More
Panel described as above

1

82337

82337.45

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

1

215

215.74

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

6

5992

35956.08

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

270

115

31182.3

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

30

230

6905.4

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

180

195

35224.2

... More
Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:2 Pair (4 core)

672

30

20482.56

... More
Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.10 Pair telephone cable

100

251

25175

... More
Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.10 pair tag block

1

3288

3288.9

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm dia PVC conduit

500

102

51330

... More
25mm dia PVC conduit

1000

116

116290

... More
32mm dia PVC conduit

500

147

73785

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required1 or 2 Module (75mmX75mm)

68

239

16252

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

-

-

-

... More
Telephone socket outlet

14

118

1661.8

... More
TV antenna socket outlet

8

118

949.6

... More
Bell Push

-

-

-

... More
RJ-45 Data Socket outlet

46

817

37582

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

-

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

3036

45

138805.92

... More
Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe.

240

37

9045.6

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm.

130

310

40349.4

... More
Above 185 sq.mm. and up to 400 sq.mm.

80

380

30412.8

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Up to 35 sq.mm.

20

29

593.4

... More
Above 185 sq.mm. and up to 400 sq.mm.

10

107

1074.7

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle

50

44

2205.5

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

10

181

1812.6

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

200

36

7218

... More
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment

-

-

-

... More
3.5 x 300 sq.mm.

100

3220

322050

... More
3.5 x 50 sq.mm

100

665

66595

... More
3.5 x 35 sq.mm

150

496

74527.5

... More
3.5 x 25 sq.mm.

100

402

40280

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
3½ X 25 sq. mm (28mm)

6

251

1506.18

... More
3½ X 35 sq. mm (32mm)

10

295

2959.4

... More
3½ X 50 sq. mm (35mm)

2

331

662.46

... More
3½ X 300 sq. mm (70mm)

4

958

3833.64

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required

-

-

-

... More
100 mm dia

10

1448

14484.5

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100mm dia

10

530

5309.4

... More
150 mm dia

10

580

5806.6

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

10

232

2325.9

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

50

536

26827.5

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

30

574

17227.5

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

4

929

3718.16

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

2

1018

2037.12

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

1

1064

1064.28

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

1

1109

1109.19

... More
GUEST HOUSE (FIRE FIGHTING)

-

-

-

... More
FIRE PUMPS - ELECTRICAL Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :

-

-

-

... More
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
1620 lpm at 70 m Head

1

242043

242043.35

... More
FIRE PUMPS - DIESEL ENGINE DRIVEN Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
1620 lpm at 70 m Head

1

431773

431773.22

... More
JOCKEY PUMP:- Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
180 lpm at 70 m Head

1

75319

75319.74

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

4

1127

4508.8

... More
Pressure Vessel Providing, fixing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge. working pressure:- 7 kg/sqcm test pressure: 10 kg/sqcm

-

-

-

... More
(450 mm dia & 2000 mm height)

1

34675

34675

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

4

872

3488.04

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
200 mm dia.

4

11087

44350.16

... More
150 mm dia.

4

6532

26131.24

... More
100 mm dia.

1

4860

4860.96

... More
80 mm dia.

2

3632

7264.82

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
150 mm dia.

2

12967

25935.82

... More
80 mm dia.

1

5607

5607.57

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 200 mm dia.

1

16233

16233.58

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS)150 mm dia.

110

2773

305088.3

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (PUMP ROOM WORKS)

-

-

-

... More
80 mm nominal bore

14.3

1374

19653.49

... More
100 mm nominal bore

6.6

1862

12294.94

... More
150 mm nominal bore

22

2605

57328.26

... More
200 mm dia (wall thickness 6.3 mm)

22

3983

87628.64

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :

-

-

-

... More
2 way - 100 mm dia M.S. Pipe (Siamese Connection)

1

4915

4915.64

... More
4 way - 150 mm dia M.S. Pipe

1

10188

10188.55

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)

-

-

-

... More
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520

-

-

-

... More
b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.

-

-

-

... More
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
450 lpm at 35 m Head

1

62851

62851.27

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump)

1

1127

1127.2

... More
Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump)

1

807

807.5

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump)

1

872

872.01

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
100 mm dia.

2

4860

9721.92

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
100 mm dia.

1

8056

8056.64

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
80 mm nominal bore

6.6

1374

9070.84

... More
100 mm nominal bore

77

1862

143440.99

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal

3

5574

16724.28

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m

3

8802

26407.56

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :

6

3792

22756.92

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :

3

1761

5284.56

... More
Providing and fixing standard fire mans axe with heavy duty insulated rubber handle.

3

1558

4674

... More
Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge. (Approx. size of door: 900mm Wide & 1500mm Height)

3

9025

27075

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

3

963

2889.45

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

1

13301

13301.84

... More
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

3

11381

34143

... More
Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

3

8645

25935

... More
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.

6

950

5700

... More
FIRE FIGHTING PANEL

-

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

-

-

-

... More
INCOMING

-

-

-

... More
250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0 500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A

-

-

-

... More
OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)

-

-

-

... More
Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.

-

-

-

... More
Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.

-

-

-

... More
DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

179163

179163.64

... More
Fabricating & Supply, installing, testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle. (As per the Technical Specifications) (At Terrace floor)

1

19000

19000

... More
Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes.

-

-

-

... More
3 Core, X 50 sqmm.

55

467

25707

... More
3 Core, X 6 sqmm.

55

262

14421

... More
Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required.

-

-

-

... More
3 Core, X 50 sqmm.

4

169

676.4

... More
3 Core, X 6 sqmm.

4

72

288.8

... More
Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required

-

-

-

... More
4 x 2.5 sq.mm

55

251

13846.25

... More
2 x 2.5 sq.mm

55

137

7576.25

... More
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge. It should be complete as per specifications & directions of Engineer-in-charge.

10

779

7799.5

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width x 50mm depth x 1.6 mm thickness.

110

440

48441.8

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.

-

-

-

... More
Two Loop Panel.

1

174420

174420.8

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.

200

2083

416758

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.

25

201

5030.75

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

3

2822

8467.14

... More
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.

3

1932

5798.58

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

33.33

2384

79464.72

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.

1

4185

4185.08

... More
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.

1

1166

1166.57

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

3

2189

6568.53

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

8

1987

15900.4

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

2773.33

126

349827.85

... More
TYPE - II RESIDENCES (CIVIL WORKS)

-

-

-

... More
Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.

-

-

-

... More
Excavation up to 1.50 mt.

120.41

123

14923.62

... More
Level 1.50 mt. to 3.0 mt. depth

38.56

212

8193.23

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

168.08

489

82211.29

... More
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.

14.23

1482

21101.81

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)

24.68

4756

117389.93

... More
Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :

-

-

-

... More
Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

127.6

216

27624.12

... More
(4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.

127.6

30

3830.55

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel)

-

-

-

... More
All works upto plinth level (Plinth beam)

3.34

7000

23380.77

... More
All works above plinth level (Plinth beam)

2.5

6751

16879.75

... More
First floor

2.96

6751

19985.62

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab)

-

-

-

... More
Ground floor

27.89

6751

188310.49

... More
First floor

20.11

6751

135780.71

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam)

-

-

-

... More
Ground floor

0.88

6751

5941.67

... More
First floor

0.88

6751

5941.67

... More
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 40 mm thick

3.24

1191

3860.78

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

143.46

4980

714443.71

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

-

-

-

... More
Ground floor

42

6358

267045.66

... More
First floor

46.05

6358

292796.49

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

-

-

-

... More
Ground floor

66.61

642

42791.6

... More
First floor

138.06

642

88692.51

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

204.67

73

14977.75

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 13mm nominal size)

20.56

286

5898.25

... More
Painting on D.P.C. with two coat of air blown bitumen 80/50 @ about 1.7 kg/sqm including cost of fuel if any.

20.56

102

2098.15

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.

-

-

-

... More
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to

-

-

-

... More
required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix

-

-

-

... More
1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge

132.61

1176

155985.16

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

-

-

-

... More
(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf.

54.81

2425

132948.23

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

54.81

322

17694.86

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

-

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

171.6

98

16978.1

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding

677.7

152

103681.32

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

-

-

-

... More
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1004.93

136

136971.96

... More
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. Second class teak wood

56.49

3508

198173.13

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (a) 35mm thick Second class teak wood.

32.13

3449

110832.11

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

-

-

-

... More
Ground floor

29

7530

218388.27

... More
First floor

20.07

7530

151139.74

... More
15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M.

26.62

287

7653.25

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

-

-

-

... More
Ground floor

251.99

239

60465

... More
First floor

407.18

239

97702.84

... More
15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)

-

-

-

... More
Ground floor

285.51

276

78815.04

... More
First floor

357.73

276

98751.37

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to I.S. : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm

-

-

-

... More
Ground floor

76.87

1084

83380.89

... More
First floor

76.87

1084

83380.89

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. : 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

-

-

-

... More
Ground floor

11.91

1133

13497.48

... More
First floor

11.91

1133

13497.48

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick

-

-

-

... More
Ground floor

28.94

1360

39369.11

... More
First floor

22.2

1360

30200.21

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

-

-

-

... More
Ground floor

13.85

1644

22771.75

... More
First floor

7.79

1644

12808.08

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. (25mm thick C.C. flooring.)

48.38

332

16086.35

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

-

-

-

... More
Ground floor

17.39

765

13315

... More
First floor

17.39

765

13315

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

-

-

-

... More
Ground floor

242.59

885

214777.06

... More
First floor

242.59

885

214777.06

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

9.97

3586

35756.61

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

54.15

47

2548.3

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

54.15

108

5894.77

... More
Wooden Painting:

-

-

-

... More
Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood.

77.44

52

4036.17

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

77.44

108

8430.12

... More
French spirit polishing : Two or more coats on new works including a coat of wood filler

64.26

311

20022.77

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (Outer surface)

659.17

156

102916.21

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work (Inner surface)

643.25

129

83384.5

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work (Ceiling)

195.72

129

25371.18

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1498.13

108

163236.24

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes

32.13

743

23885.12

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (a) 250mm x 16mm.

29

181

5276.84

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
(a) 250 mm x 10mm

29

80

2331.6

... More
(a) 200 mm x 10mm

29

69

2018.98

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm

58

46

2683.08

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.

4.2

1760

7394.27

... More
Providing & applying 100% solids, flexible, elastomeric, UV stable, 2 component, waterproof, fast setting, monolithic, hydrophobic in nature, NO-VOC, CFTRI-US-FDA-175-300 coating on prepared surface as following :- P/L DONCRETE/EQUIVALENTPP solvent free primer @ 100gsm per m2 forconjunction of DONCRETE/EQUIVALENT PU conforming to ASTM-D-2369 C,ASTM-D-2369, ASTM-D-638, ASTM-D-4541, ASTM-D- 638, ASTMD- 2240, ASTM-E-96, ASTM-B-117-73, ASTM-D-91, ASTM-D-624, ASTM-D-4060, ASTM-C-8, ASTM-D-512, ASTM-G-53, ASTM-3912 @ 1 Ltr per m2 for 1.00 mm thick. The coating shall be carried out in single application with multiple passes, using high pressure plural component reactor strictly as per manufacture specification, rate materials, labor, and tools. Surface preparation includes repairs of holes, cracks, voids, pinholes, bug holes. Joints shall be filled with epoxy putty Confirming the ASTM D 638, ASTMD 4541, and ASTM D 2369. The corner rounding/angle fillet shall be prepared/replaced as required to smooth transition of coating from horizontal to vertical surfaces.

27.98

902

25251.95

... More
P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia.

63.7

366

23375.99

... More
Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. With non decorative veneering on both sides

11.31

1968

22264.19

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick.

311.32

718

223552.67

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

101.98

587

59953.02

... More
TYPE - II RESIDENCES (INTERNAL W/S & SANITATION WORKS)

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:

-

-

-

... More
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

4

4725

18901.36

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:

-

-

-

... More
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

4

1554

6218.2

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

4

722

2890.2

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

4

161

647.84

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

4

77

311.28

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

4

1122

4491

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink)15 mm nominal bore

8

401

3208

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore

8

68

546

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :

-

-

-

... More
100 mm diameter

4

135

541.72

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

-

-

-

... More
15 mm nominal bore

4

468

1872.56

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.

-

-

-

... More
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

4

495

1980.08

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required

-

-

-

... More
Kitchen sink with drain board

-

-

-

... More
510x1040 mm bowl depth 200 mm

4

4998

19995.08

... More
Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete

-

-

-

... More
Flexible Pipe

-

-

-

... More
32mm Dia

4

83

333.92

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15mm nominal bore

4

353

1415.48

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.

-

-

-

... More
15mm nominal bore

4

557

2231.48

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
For Internal Toilet

-

-

-

... More
15 mm nominal outer dia Pipes

13.29

347

4619.47

... More
20 mm nominal outer dia Pipes

39.6

375

14865.05

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm nominal bore

100.1

233

23414.39

... More
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall

-

-

-

... More
Terrace loop & Tank Filling Pipe

-

-

-

... More
25 mm nominal bore

44

385

16949.68

... More
Providing , checking, storing, fixing in position of approved quality Screwed ends Brass float valve with brass ball float and PTFE seat suitable for Body test pressure of 15Kg/sqcm of the following sizes:

-

-

-

... More
25mm

4

1843

7372

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :

-

-

-

... More
25mm diameter pipe

44

21

929.28

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :

-

-

-

... More
25 to 40 mm nominal bore

16

636

10187.68

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
For vertical pipe connection with terrace ringmain

-

-

-

... More
20 mm nominal bore

8

377

3016.16

... More
25mm nominal bore

8

434

3476.72

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

7

15360

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
110 mm dia (for rain water)

24

263

6324.48

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single Push Fit Coupler

-

-

-

... More
110 mm dia

7.2

89

641.52

... More
Single tee with door

-

-

-

... More
110x110x110 mm

2

163

327

... More
Plain bend 87.5 deg

-

-

-

... More
110 mm dia

4

104

419.92

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
110 mm dia

9.6

259

2488.9

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

2

208

416.5

... More
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.

-

-

-

... More
Internal Toilet (Soil & Waste Pipe)

-

-

-

... More
75 mm

22

479

10554.5

... More
110 mm

14.96

679

10161.58

... More
Exposed on Wall (Soil & Waste Pipe)

-

-

-

... More
110 mm

73.2

679

49721.1

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
Bend without door (45°)

-

-

-

... More
100mm

4

209

836

... More
75mm

12

128

1539

... More
Y' Fitting without door

-

-

-

... More
100mm

4

394

1577

... More
75mm

12

218

2622

... More
Single Tee without door

-

-

-

... More
110mm

4

346

1387

... More
75 mm

12

213

2565

... More
Single Tee with door

-

-

-

... More
110mm

4

403

1615

... More
Reduced Tee with door

-

-

-

... More
110mm x 75mm

8

351

2812

... More
Coupler

-

-

-

... More
110mm

21.6

209

4514.4

... More
Clean Out Plug (COP)

-

-

-

... More
110mm

4

190

760

... More
75 mm

4

133

532

... More
Vent Cowl

-

-

-

... More
110mm

6

85

513

... More
Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.

-

-

-

... More
For Wash basin & Urinal

-

-

-

... More
32mm dia. Pipe (for wash basin & sunken toilet spout)

60.32

175

10601.24

... More
Elbow (90°)

-

-

-

... More
32mm

8

38

304

... More
Elbow (45°)

-

-

-

... More
32mm

4

42

171

... More
Coupler

-

-

-

... More
32mm

14.4

33

478.8

... More
Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm x 50mm/40mm (Toilet)

4

1159

4636

... More
Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm (Toilet)

4

1092

4370

... More
110mm x 75mm (Kitchen)

4

1092

4370

... More
Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
Rectangular type with openable circular lid

-

-

-

... More
150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)

12

137

1650.24

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :

-

-

-

... More
150 x 100mm size P-type

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

1909

7636.64

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:

-

-

-

... More
100 mm diameter

12

309

3716.88

... More
Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.

-

-

-

... More
All kind of soil

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

36

245

8852.04

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:

-

-

-

... More
100mm dia SW pipe

36

673

24251.04

... More
TYPE - II RESIDENCES (INTERNAL ELECTRIFCATION WORKS)

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

90

1176

105890.4

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

770

186

143889.9

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

84

220

18527.04

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

1320

267

353588.4

... More
2 X 6 sq. mm + 1 X 4 sq. mm earth wire

144

352

50700.96

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.

32

382

12241.92

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

20

469

9399.6

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required

12

295

3551.28

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

15

32

481.2

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

32

69

2232.96

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

66

95

6299.04

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

12

176

2123.64

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required

-

-

-

... More
Upto 450 mm sweep

8

360

2887.28

... More
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.

8

166

1328.16

... More
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).

24

1510

36252

... More
Supply of Surface mounting round 15 Watt to 18 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect

6

1629

9775.5

... More
Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,

2

5047

10094.7

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

30

105

3151.8

... More
Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect.

30

222

6669

... More
Supplying of 9 Watt Decorative LED Wall Light complete in all respect.

4

1827

7311.2

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan

12

2189

26274.12

... More
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN

8

2280

18247.6

... More
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double Door

4

1856

7426.68

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

28

205

5748.96

... More
Double pole

4

526

2104.48

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

4

10

41.72

... More
Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.

-

-

-

... More
The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.

-

-

-

... More
The minimum clearances between bus bars shall be as follows :

-

-

-

... More
Phase to phase - minimum 20mm

-

-

-

... More
Phase to neutral-minimum 15mm

-

-

-

... More
METERING PANEL TYPE-II

-

-

-

... More
Incoming :

-

-

-

... More
One (1) No 63 Amp. 4P MCCB of 25KA

-

-

-

... More
Metering :

-

-

-

... More
1 Set of CT's one of 60/ 5Amp ratio for Multifunction Meter

-

-

-

... More
One (1) Set of Phase Indication Lamp.

-

-

-

... More
Bus Bar :

-

-

-

... More
One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.

-

-

-

... More
Outgoing :

-

-

-

... More
Phase indication lamps on each outgoing to be provided.

-

-

-

... More
32 Amps DP MCB of 10KA (Ics=Icu) Breaking Capacity- 5 No

-

-

-

... More
10 Amps DP MCB of 10KA (Ics=Icu) Breaking Capacity- 2 No

-

-

-

... More
1 Phase Energy Meter-5Nos.

-

-

-

... More
Panel described as above

1

57234

57234.65

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

1

215

215.74

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

2

5992

11985.36

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

90

115

10394.1

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

20

230

4603.6

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

60

195

11741.4

... More
Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:

-

-

-

... More
2 Pair (4 core)

384

30

11704.32

... More
Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.

-

-

-

... More
10 Pair telephone cable

100

251

25175

... More
Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.

-

-

-

... More
10 pair tag block

1

3288

3288.9

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm dia PVC conduit

80

102

8212.8

... More
25mm dia PVC conduit

150

116

17443.5

... More
32mm dia PVC conduit

80

147

11805.6

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required

-

-

-

... More
1 or 2 Module (75mmX75mm)

16

239

3824

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

-

-

-

... More
Telephone socket outlet

8

118

949.6

... More
TV antenna socket outlet

8

118

949.6

... More
Bell Push

4

112

449.12

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

4

79

317.6

... More
Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe.

240

37

9045.6

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm.

80

310

24830.4

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Up to 35 sq.mm.

10

29

296.7

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle

10

44

441.1

... More
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment

-

-

-

... More
3.5 x 25 sq.mm.

80

402

32224

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
3½ X 25 sq. mm (28mm)

2

251

502.06

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100mm dia

5

530

2654.7

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

5

232

1162.95

... More
GUARD ROOM (CIVIL WORKS)

-

-

-

... More
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.

-

-

-

... More
Excavation up to 1.50 mt.

42.05

123

5211.68

... More
Level 1.50 mt. to 3.0 mt. depth

13.33

212

2832.36

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

20.97

489

10256.85

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors.

7.55

4756

35911.42

... More
Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand.

2.65

1482

3929.71

... More
Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :

-

-

-

... More
Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

24.74

216

5355.96

... More
(4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.

24.74

30

742.69

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

1.02

7000

7140.23

... More
Same as above for ground floor (Above Plinth level)

0.87

6751

5874.15

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab)

-

-

-

... More
Same as above for ground floor

4.51

6751

30451.07

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam)

-

-

-

... More
Same as above for ground floor

0.25

6751

1687.98

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing)

2.47

7000

17290.57

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

0.69

7000

4830.16

... More
Same as above for ground floor (Above Plinth level)

0.58

6751

3916.1

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

49.23

4980

245169.83

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate12.5 mm nominal size).

5.23

286

1500.38

... More
Painting on D.P.C. with two coats of air blown bitumen VG-10 grade @ 1.7 kg/sqm approximate including cost of fuel if any.

5.23

102

533.72

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

15.85

6358

100777.95

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class -150 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

18.98

642

12193.13

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

19.94

73

1459.21

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

9.1

7530

68528.73

... More
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)

10.45

287

3004.38

... More
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)

80.18

276

22133.69

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

135.3

239

32465.24

... More
Making grooves 10 to 12 mm wide x 8mm deep in plaster of the walls or in ceiling vertically or horizontally as required.

40.92

54

2239.96

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.

16.6

428

7119.24

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. (25mm thick)

18.67

332

6207.78

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick

4.46

462

2061.77

... More
Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

5.22

3586

18721.11

... More
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick.

66.4

64

4253.58

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

3.47

765

2656.87

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

18.98

885

16803.94

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

7.35

1670

12279.42

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

-

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

26.4

98

2612.02

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding

51.3

152

7848.39

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

58.14

91

5320.39

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

-

-

-

... More
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

91.55

136

12478.27

... More
Providing & laying cement concrete in 1:2:4 of not less than stregth M-150 Stone ballast (20mm nominal size) approved coarse sand and cement, curing complete, including cost of form work. In foundation and floors.

0.62

5501

3410.72

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Inner walls)

80.18

129

10393.73

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

135.3

119

16164.29

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Ceiling area)

32.06

129

4155.94

... More
Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work.

247.53

108

26970.87

... More
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete. (a) 250mm x 16mm

4

135

541

... More
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete

-

-

-

... More
(a) 250 mm x 10mm

4

58

234.32

... More
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete. 125mm

4

27

111.6

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.

6.3

743

4683.36

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

10.71

47

504.01

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

10.71

108

1165.89

... More
Wooden Painting:

-

-

-

... More
Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood.

14.7

52

766.16

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

14.7

108

1600.24

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-

-

-

-

... More
in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix

-

-

-

... More
1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120mm and minimum thickness at khurra as 65 mm.

18.55

1176

21819.81

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

3.2

273

876.22

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick.

39.45

718

28328.26

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

20.98

587

12333.93

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

16.92

671

11357.21

... More
GUARD ROOM (INTERNAL W&S SANITATION WORKS)

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:

-

-

-

... More
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

2

4725

9450.68

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:

-

-

-

... More
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

2

1554

3109.1

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

2

722

1445.1

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

2

161

323.92

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

2

77

155.64

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

2

1122

2245.5

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink)

-

-

-

... More
15 mm nominal bore

4

401

1604

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :

-

-

-

... More
45 cm length

-

-

-

... More
15 mm nominal bore

4

68

273

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15mm nominal bore

2

353

707.74

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
For Internal Toilet

-

-

-

... More
15 mm nominal outer dia Pipes

5.76

347

2002.12

... More
20 mm nominal outer dia Pipes

13.2

375

4955.02

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm nominal bore

29.92

233

6998.59

... More
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall

-

-

-

... More
Terrace loop & Tank Filling Pipe

-

-

-

... More
25 mm nominal bore

55

385

21187.1

... More
Providing , checking, storing, fixing in position of approved quality Screwed ends Brass float valve with brass ball float and PTFE seat suitable for Body test pressure of 15Kg/sqcm of the following sizes:

-

-

-

... More
25mm

2

1843

3686

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :

-

-

-

... More
25mm diameter pipe

55

21

1161.6

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :

-

-

-

... More
25 to 40 mm nominal bore

2

636

1273.46

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
For vertical pipe connection with terrace ringmain

-

-

-

... More
20 mm nominal bore

2

377

754.04

... More
25mm nominal bore

2

434

869.18

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

500

7

3840

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
110 mm dia (for rain water)

18

263

4743.36

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single Push Fit Coupler

-

-

-

... More
110 mm dia

4.8

89

427.68

... More
Single tee with door

-

-

-

... More
110x110x110 mm

2

163

327

... More
Plain bend 87.5 deg

-

-

-

... More
110 mm dia

4

104

419.92

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
110 mm dia

7.2

259

1866.67

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

2

208

416.5

... More
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.

-

-

-

... More
Internal Toilet (Soil & Waste Pipe)

-

-

-

... More
75 mm

13.2

479

6332.7

... More
110 mm

15.84

679

10759.32

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
Bend without door (45°)

-

-

-

... More
75mm

2

128

256.5

... More
Y' Fitting without door

-

-

-

... More
75mm

2

218

437

... More
Single Tee without door

-

-

-

... More
75 mm

2

213

427.5

... More
Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.

-

-

-

... More
For Wash basin & Urinal

-

-

-

... More
32mm dia. Pipe (for wash basin & sunken toilet spout)

6.16

175

1082.62

... More
Elbow (90°)

-

-

-

... More
32mm

2

38

76

... More
Elbow (45°)

-

-

-

... More
32mm

2

42

85.5

... More
T fitting

-

-

-

... More
32mm

2

42

85.5

... More
Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm x 50mm/40mm (Toilet)

2

1159

2318

... More
Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
Rectangular type with openable circular lid

-

-

-

... More
150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)

2

137

275.04

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :

-

-

-

... More
150 x 100mm size P-type

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

1909

3818.32

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:100 mm diameter

6

309

1858.44

... More
Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

6

245

1475.34

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:100mm dia SW pipe

6

673

4041.84

... More
GUARD ROOM (INTERNAL ELECTRIFICATION WORKS)

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

14

1176

16471.84

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

110

186

20555.7

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

132

267

35358.84

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.

4

382

1530.24

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

2

469

939.96

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required

2

295

591.88

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

2

32

64.16

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

6

69

418.68

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

10

95

954.4

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

2

176

353.94

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required

-

-

-

... More
Upto 450 mm sweep

2

360

721.82

... More
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.

2

166

332.04

... More
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).

2

1510

3021

... More
Supply of Surface mounting round 12 Watt to 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect

2

1550

3100.8

... More
Supplying of LED mirror light luminaire with 10W watt complete with electronic  ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor.

2

1068

2137.5

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

4

105

420.24

... More
Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect.

4

222

889.2

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan

2

2189

4379.02

... More
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN

2

2280

4561.9

... More
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double Door

2

1856

3713.34

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

12

205

2463.84

... More
Double pole

2

526

1052.24

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

4

10

41.72

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

2

215

431.48

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

2

5992

11985.36

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

90

115

10394.1

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

20

230

4603.6

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

60

195

11741.4

... More
Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:

-

-

-

... More
2 Pair (4 core)

96

30

2926.08

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm dia PVC conduit

20

102

2053.2

... More
25mm dia PVC conduit

40

116

4651.6

... More
32mm dia PVC conduit

20

147

2951.4

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required

-

-

-

... More
1 or 2 Module (75mmX75mm)

2

239

478

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

-

-

-

... More
Telephone socket outlet

2

118

237.4

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm.

160

310

49660.8

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Up to 35 sq.mm.

20

29

593.4

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle

20

44

882.2

... More
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment

-

-

-

... More
2 x 10 sq.mm,

200

235

47120

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
2 X 10 sq. mm (19mm)

4

193

773.16

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100mm dia

10

530

5309.4

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

10

232

2325.9

... More
ELECTRIC SUB STATION (CIVIL WORKS)

-

-

-

... More
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.

-

-

-

... More
Excavation up to 1.50 mt.

58.51

123

7251.73

... More
Level 1.50 mt. to 3.0 mt. depth

11.41

212

2424.4

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

77.54

489

37926.36

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

12.01

4756

57125.32

... More
Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand.

7.9

1482

11714.99

... More
Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :

-

-

-

... More
Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

38.76

216

8391.15

... More
(4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.

38.76

30

1163.58

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

0.65

7000

4550.15

... More
Same as above for ground floor (Above Plinth level)

0.47

6751

3173.39

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab)

-

-

-

... More
Same as above for ground floor

8.95

6751

60429.51

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam)

-

-

-

... More
Same as above for ground floor (Tie beam)

2.11

7000

14770.49

... More
Same as above for ground floor (above plinth level)

1.96

6751

13233.72

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing)

12.04

7000

84282.77

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

3.04

7000

21280.7

... More
Same as above for ground floor (Above Plinth level)

3.3

6751

22281.27

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

45.24

4980

225299.27

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate12.5 mm nominal size).

7.64

286

2191.76

... More
Painting on D.P.C. with two coats of air blown bitumen VG-10 grade @ 1.7 kg/sqm approximate including cost of fuel if any.

7.64

102

779.66

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

23.69

6358

150626.47

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

35.72

7530

268994.1

... More
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)

34.16

287

9821

... More
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)

107.98

276

29807.88

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

180.15

239

43226.99

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.

32

428

13723.84

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. (25mm thick)

14.18

332

4714.85

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick

3.2

462

1479.3

... More
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick.

192

64

12299.52

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods, gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

-

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

7.2

98

712.37

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding

205.88

152

31497.58

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

126.23

91

11551.31

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.

7.43

743

5523.39

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Inner walls)

107.98

129

13997.45

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

180.15

119

21522.52

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Ceiling)

52.46

129

6800.39

... More
Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work.

340.58

108

37109.6

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

35.06

47

1649.92

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

35.06

108

3816.63

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-

-

-

-

... More
in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix

-

-

-

... More
1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120mm and minimum thickness at khurra as 65 mm.

32.92

1176

38722.81

... More
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire

45.03

21

945.63

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

12.24

2527

30930.48

... More
Providing and fixing ball bearing for rolling shutters.

4

340

1362.28

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.

12

755

9060.24

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

18.69

273

5117.7

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick.

75.54

718

54243.76

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

47.67

587

28024.72

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

70.43

671

47274.73

... More
ELECTRIC SUB STATION (ELECTRIFICATION WORKS)

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

13

1176

15295.28

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

65

186

12146.55

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

35

220

7719.6

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

132

267

35358.84

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

2

469

939.96

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

2

32

64.16

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

9

69

628.02

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

10

95

954.4

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required

-

-

-

... More
Upto 450 mm sweep

3

360

1082.73

... More
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.

3

166

498.06

... More
Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 42W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor

2

3418

6836.2

... More
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).

4

1510

6042

... More
Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required.

2

1589

3178.7

... More
Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,

2

5047

10094.7

... More
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.

-

-

-

... More
300mm EXHAUST FAN

3

2280

6842.85

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
4 Way Double door

1

3281

3281.06

... More
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required

-

-

-

... More
40 amps 4P MCB

1

2429

2429.15

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

5

205

1026.6

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

1

10

10.43

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

1

215

215.74

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

1

5992

5992.68

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

45

115

5197.05

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

30

195

5870.7

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm.

80

310

24830.4

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Up to 35 sq.mm.

10

29

296.7

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle

10

44

441.1

... More
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment

-

-

-

... More
4 x 10 sq.mm

100

291

29165

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
4 X 10 sq. mm (25mm)

2

215

431.48

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100mm dia

5

530

2654.7

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

5

232

1162.95

... More
CC ROAD

-

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres (DSR-16.1)

3928.34

152

600446.77

... More
Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. (DSR-4.1.8) Brick edging

39.28

4756

186834.53

... More
Class 150 brick work in 1:6 cement and coarse sand of 2.30 fineness modulus mortar in foundation and plinth including supply of all materials,labour and tools and plants etc.required for proper completion of the work.

90.35

4980

449951.13

... More
Supplying and stacking at site:

-

-

-

... More
90 mm to 45 mm size stone aggregate. (DSR-16.3.1)

294.63

1465

431694.82

... More
63 mm to 45 mm size stone aggregate (DSR-16.3.2)

294.63

1142

336576.47

... More
Local Sand @ 25% of Item No. 3a (DSR-2.27)

73.66

1482

109231.15

... More
Stone screening 11.2 mm nominal size (Type B) (DSR-16.3.7)

196.42

1569

308279.23

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)

589.25

5501

3241558.53

... More
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . (DSR-16.4)

589.25

731

430759.43

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. (For temprature reinforcement @ 0.5% of Concrete Volume) (DSR-5.22.6)

231.28

7530

1741684.11

... More
Trimixing of the surface of the cement concrete laid. (M.R.)

3928.34

332

1306173.05

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound.

654.72

5

3915.23

... More
INTERLOCKING TILES

-

-

-

... More
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. (DSR-2.6.1)

75.9

123

9407.05

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. (DSR-4.1.8)

66.41

4756

315877.84

... More
Class M-150 brick work in 1:6 cement coarse sand (of 2.5 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (DSR- 6.1.2)

21.82

4980

108665.56

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. Cement Grey/Ordinary Red

316.25

755

238775.08

... More
KERB STONE WITH K.C. DRAIN

-

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3(1 cement: 3 coarse sand ) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). (DSR-16.69)

114.17

6998

799027.88

... More
Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. (DSR-4.1.8)

49.1

4756

233543.17

... More
Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete. (DSR-16.49)

163.68

2110

345369.71

... More
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats) (DSR-16.47.1)

585.16

130

76176.13

... More
LANDSCAPING WORKS

-

-

-

... More
Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment).

577.65

279

161337.65

... More
Carrigae of sludge upto 5 K.M.

577.65

178

102914.12

... More
Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm

96.28

303

29260.45

... More
Carrigae of manure upto 5 K.M.

96.28

178

17153.24

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.

96.28

34

3342.84

... More
Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately).

673.93

49

33514.54

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately).

-

-

-

... More
Holes 0.9 m dia. and 0.90 m deep.

90

318

28685.7

... More
Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.

30

617

18525

... More
Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge.

15

522

7837.5

... More
Plantation of trees. (Decorative Plants)

80

1425

114000

... More
Tree guard

90

3276

294855.3

... More
Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf.

328.92

16

5532.43

... More
EXTERNAL W/S & SEWERAGE WORKS

-

-

-

... More
Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.

-

-

-

... More
up to 1.50 m depth

-

-

-

... More
Pipes 80 mm to 300 mm diameter

390.5

245

96020.05

... More
1.50 m to 3.00 m depth

-

-

-

... More
Pipes 80 mm to 300 mm diameter

33

245

8114.37

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)

-

-

-

... More
Depth not exceeding 1.5 meter

1171.5

50

58938.17

... More
Depth 1.5 to 3.00 meter

198

56

11282.04

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.

-

-

-

... More
150 mm. dia. RCC Pipes

374

388

145313.96

... More
250 mm. dia. RCC Pipes

33

628

20733.57

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design

-

-

-

... More
150 mm. dia. RCC Pipes

374

518

194057.38

... More
250 mm. dia. RCC Pipes

33

710

23431.65

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.

-

-

-

... More
Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).

-

-

-

... More
With common burnt clay FPS (non modular) bricks of class designation 75

-

-

-

... More
(i) For Sewer Line

23

8917

205091.92

... More
Extra for depth for manholes:

-

-

-

... More
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5

11.5

6162

70866.91

... More
Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).

-

-

-

... More
With common burnt clay FPS (non modular) bricks of class designation 75

-

-

-

... More
(i) For Sewer Line

8

18437

147501.12

... More
Extra for depth for manholes:

-

-

-

... More
Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5

4

7391

29565.32

... More
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

70

386

27063.4

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling, fixing specials for pressure pipe etc. . (external work)

-

-

-

... More
80mm nominal bore.

33

800

26403.3

... More
65mm nominal bore.

22

688

15150.52

... More
50mm nominal bore.

66

585

38635.74

... More
40mm nominal bore.

22

473

10426.68

... More
32mm nominal bore.

44

414

18259.56

... More
25mm nominal bore.

220

359

79039.4

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.

-

-

-

... More
80mm nominal bore.

1

1818

1818.63

... More
65mm nominal bore.

1

1216

1216.46

... More
50mm nominal bore.

2

716

1433.72

... More
40mm nominal bore.

2

576

1153.64

... More
32mm nominal bore.

2

481

963.02

... More
25mm nominal bore.

7

434

3042.13

... More
Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

13194

52778.48

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

11

7584

83431.37

... More
Supply, Installation, testing & commissioning of Vertical in line pumping set complete. The rate shall include the cost of electrical panel and piping work complete

-

-

-

... More
Domestic Water Supply pumps :

-

-

-

... More
Capacity/Flow Rate - 12.5 m3/hr

-

-

-

... More
Head - 45 m

-

-

-

... More
Location - 1 set in UGT (1 set = 2nos(1W+1S))

1

422940

422940

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

1

1127

1127.2

... More
Supply, fixing, testing and commissioning of Level Float Switch, for dry run protection of pump as per specifications:-

-

-

-

... More
Lehry Make Level Float Switch

-

-

-

... More
1) Body : Polypropylene, Highly Durable, Water Proof

-

-

-

... More
2) Rating : IP68

-

-

-

... More
3) Temperature : 0-50DegC

-

-

-

... More
4) Cable : PVC

-

-

-

... More
Size 5 Mtr, Item Code (LIV-LFV-RED- MTR) (location : UG TANK)

1

2123

2123.25

... More
SEPTIC TANK & SOAK PIT

-

-

-

... More
Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.

-

-

-

... More
In all kind of soil upto 1.5m depth

47.38

123

5872.28

... More
In all kind of soil upto 1.5m to 3.0m. depth

45.09

212

9580.72

... More
In all kind of soil upto 3.0m to 4.5m. depth

12.02

301

3618.26

... More
Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size)

4.68

5501

25745.43

... More
Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand)

19.51

5146

100409.39

... More
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.

3.98

6316

25138.44

... More
Suspended floors, roofs, landings, balconies and access platform.

26.52

647

17170.37

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

3.12

7478

23332.17

... More
12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand)

82.6

306

25334.25

... More
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.

12

380

4564.08

... More
Providing and fixing C.I. tee at the inlet and outlet of septic tank.

2

433

867.22

... More
Providing & fixing 75mm dia vent pipes.

1

729

729.5

... More
Providing & fixing of 75mm dia cast iron terminal guard.

1

237

237.89

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.

-

-

-

... More
M.D. -10- Circular shape 500mm internal diameter

2

818

1637.54

... More
M.D. -2.5- Circular shape 450mm internal diameter

4

816

3266.84

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks

2

18756

37512.64

... More
RAIN WATER HARVESTING

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.

-

-

-

... More
In all kind of soil upto 1.5m depth

22.59

123

2799.8

... More
In all kind of soil upto 1.5m to 3.0m. depth

22.59

212

4799.92

... More
In all kind of soil upto 3.0m to 4.5m. depth

22.59

301

6800.04

... More
In all kind of soil upto 4.5 m to 6.0m. depth

10.54

389

4105.86

... More
Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

1.2

5501

6601.39

... More
Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.

24.14

5146

124237.96

... More
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.

1.61

6316

10169.07

... More
Suspended floors, roofs, landings, balconies and access platform.

10.75

647

6960.09

... More
Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

1.9

7478

14208.69

... More
12mm cement plaster on rough side of single or half brick wall mix

-

-

-

... More
1:3 (1 cement : 3 Coarse sand)

46.16

306

14157.73

... More
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:

-

-

-

... More
With 20x20mm square bar

10

380

3803.4

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.

-

-

-

... More
M.D. -10- Circular shape 500mm internal diameter

1

818

818.77

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.

-

-

-

... More
Drilling of 300mm dia bore hole manually.

15

576

8648.25

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.

-

-

-

... More
150 mm nominal size dia

15

563

8457

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

12.13

1054

12787.69

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

13.11

1074

14081.19

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

13.11

1074

14081.19

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

1

1413

1413.61

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.

-

-

-

... More
In all kind of soil upto 1.5m depth

10.05

123

1245.6

... More
In all kind of soil upto 1.5m to 3.0m. depth

4.06

212

862.67

... More
Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

1.04

5501

5721.21

... More
Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.

3.52

5146

18115.89

... More
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.

1.38

6316

8716.34

... More
Suspended floors, roofs, landings, balconies and access platform.

7.27

647

4706.96

... More
Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

1.63

7478

12189.56

... More
15mm cement plaster on rough side of single or half brick wall mix

-

-

-

... More
1:3 (1 cement : 3 Coarse sand)

17.6

306

5398.1

... More
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:

-

-

-

... More
With 20x20mm square bar

12

380

4564.08

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.

-

-

-

... More
M.D. -10- Circular shape 500mm internal diameter

2

818

1637.54

... More
Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.

-

-

-

... More
up to 1.50 m depth

-

-

-

... More
Pipes 80 mm to 300 mm diameter

215.6

245

53013.88

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.

-

-

-

... More
150 mm. dia. RCC Pipes

215.6

388

83769.22

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design

-

-

-

... More
150 mm. dia.

215.6

518

111868.37

... More
Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as per design. With FPS bricks

20

6652

133045

... More
Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:

-

-

-

... More
Drain 300 wide average. Depth 45 cm with R.C.C. slab

350

3069

1074405.5

... More
Drain 450 wide average. Depth 45 cm with R.C.C. slab

110

4083

449210.3

... More
Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset

-

-

-

... More
Product Type: SUBMERSIBLE DRAINAGE PUMP Product Configuration Pump Classification: Standard Pump Component Materials Volute Material: Cast Iron FG 260 Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Seal Material: Carbon/Ceramic/NBR/S.S 304 Motor Specifications Phase: 3 Voltage: 380-415V Cable Length: Standard - 5 metres Cable Length: Additional - 0 metres: 0 Pipework Connection Float Switch: With Float Switch Solids Diameter Limit Maximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( 1No. for UGT)

1

52810

52810.5

... More
EXTERNAL ELECTRICAL WORKS

-

-

-

... More
H.T. VCB (11KV) ( LOCATED IN METER ROOM)

-

-

-

... More
Design, manufacturing, testing at works, supply of HT Panel as per specification and comprising of the following :-

-

-

-

... More
INCOMER/OUTGOING PANEL

-

-

-

... More
630 A Vacuum circuit breaker of 18.3 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, vertical isolation,vermin proof,fully interlocked horizontal drawout type having double isolation.

-

-

-

... More
Manually and motor operated, spring charged( release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indicator.

-

-

-

... More
630 amp air insulated but encapsulated,PVC insulated Copper bus bars.

-

-

-

... More
C.T. chamber with C.T.'s 10/5.

-

-

-

... More
15 VA burden for protection (class 5P 10).

-

-

-

... More
Following protection shall be provided:

-

-

-

... More
1 Nos IDMT relay with instantaneous 2 nos. over currrent (50, 50 N) element and 1 no. instantaneous earth fault element(50-50N).(O/C setting 50%-200% and E/F setting 20%-80%)

-

-

-

... More
All wiring necessary for the above including inter-connections. The size of the conductor should not be less than 2.5 sq. mm. Copper wire where required.

-

-

-

... More
Test terminal block, fuses/2A SPMCB , circuit labels,set of phase, indication lamps etc. as per standard practise as under.

-

-

-

... More
Red - Breaker close (ON)

-

-

-

... More
Green - Breaker open (OFF)

-

-

-

... More
Amber - auto trip

-

-

-

... More
Clear - trip circuit healthy

-

-

-

... More
Blue spring charged

-

-

-

... More
Control :- T-N-C (Trip, Neutral. Close) breaker control switch with indication arrangement.

-

-

-

... More
Terminal boxes with single gland trifucating cable box suitable for 11 KV Aluminium XLPE (E) cable of size 3C x 70 Sq. mm. for incoming/outgoing breaker.

-

-

-

... More
HT Danger Plate.(as per IS specification)

-

-

-

... More
2 Runs of 40 X 5 mm earth bus shall be provided for the full length of the panel.

-

-

-

... More
Power Pack, Battery power pack shall be rated for minimum five (5) trippings. For DC power one no. source selector switch to be incorporated i.e. one source from power pack and other from outside.

-

-

-

... More
Necessary D.C. supply healthy indication lamp (White Colour), switch with alarm.

-

-

-

... More
Surge supressor as required.

-

-

-

... More
DC Voltmeter, 0-10 Volt, Digital type.

-

-

-

... More
HT Panel switchboard complete with all interconnections, labels, wiring etc, complete as described above in item nos.A and B and as per specifications.

1

473111

473111.4

... More
Supply of 3 core stranded aluminium conductor 11KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments).

-

-

-

... More
70 sq. mm 3 core

200

1648

329650

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Upto 120 sq. mm

180

421

75790.8

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Upto 120 sq. mm

20

61

1235.2

... More
Supply and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 70Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.

2

1664

3328.38

... More
Supply and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 70 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.

2

3824

7649.66

... More
Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.

-

-

-

... More
Main LT Panel

-

-

-

... More
Incoming :

-

-

-

... More
2 No 630 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity

-

-

-

... More
Metering :

-

-

-

... More
1 Set of CT's one of 630/ 5Amp ratio for Multifunction Meter

-

-

-

... More
1 Set of CT's one of 630/ 5Amp ratio 27,47,59,81.

-

-

-

... More
1 Set of CT's one of 200/ 5Amp ratio for APFC relay.

-

-

-

... More
1 Set of Phase Indication Lamp.

-

-

-

... More
Bus Bar :

-

-

-

... More
One (1) No. 800 Amp. FP aluminimum bus bar of suitable length.

-

-

-

... More
Outgoing :

-

-

-

... More
Phase indication lamps on each outgoing to be provided.

-

-

-

... More
500 Amps TPN MCCB of 35KA -2 No

-

-

-

... More
200 Amps TPN MCCB of 35KA -1 No

-

-

-

... More
63 Amps TPN MCCB of 35KA -2 No

-

-

-

... More
40 Amps TPN MCCB of 35KA -1 No

-

-

-

... More
32 Amps DP MCB of 10KA -2 No

-

-

-

... More
2 No. SPACE & SPARE

-

-

-

... More
Panel described as above

1

416575

416575.95

... More
FEEDER PANEL -1

-

-

-

... More
INCOMING

-

-

-

... More
1No. Of 500 Amps FP MCCB of 35KA breaking capacity

-

-

-

... More
Metering :

-

-

-

... More
1 Set of CT's one of 500/ 5Amp ratio for Multifunction Meter

-

-

-

... More
One (1) Set of Phase Indication Lamp.

-

-

-

... More
BUS BAR

-

-

-

... More
1 Set of 600 Amps TPN Aluminium Bus Bars

-

-

-

... More
OUTCOMING

-

-

-

... More
400 Amps FP MCCB of 35KA - 2 No

-

-

-

... More
63 Amps FP MCCB of 25KA - 2 No

-

-

-

... More
25 Amps DP MCB of 10KA -2 No

-

-

-

... More
10 Amps DP MCB of 10KA - 6 No

-

-

-

... More
Timer switch - 6 No

-

-

-

... More
2 No. SPACE & SPARE

-

-

-

... More
Panel described as above

1

225573

225573.7

... More
CAPACITOR PANEL-60 KVAR

-

-

-

... More
SITC APFC Panel of 60 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static 5,10,15,25 KVAR capacitors (without oil) in tier formation complete with following TPN MCCB as incomer of the panel, 4 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd.

-

-

-

... More
The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in

-

-

-

... More
independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated.

-

-

-

... More
Incoming

-

-

-

... More
One (1) No 200 Amp. 4P MCCB of 25 KA Breaking capacity

-

-

-

... More
BUS BAR

-

-

-

... More
1 Set of 250 Amps TPN Aluminium Bus Bars

-

-

-

... More
OUT GOING

-

-

-

... More
01 No. 63 Amps. TP MCCB (25 KA)-25 KVAR

-

-

-

... More
01 No. 40 Amps. TP MCCB (25 KA)- 15 KVAR

-

-

-

... More
02 No. 32 Amps. TP MCCB (25 KA) - 10 KVAR

-

-

-

... More
Panel described as above

1

162184

162184

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

2

181

362.52

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

4

4257

17028.44

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

8

4985

39882.8

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required

4

9459

37836.04

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

216

684

147769.92

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

432

105

45385.92

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

200

150

30156

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

140

809

113293.6

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

280

165

46261.6

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm.

270

259

69943.5

... More
Above 185 sq.mm. and up to 400 sq.mm.

360

317

114336

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Up to 35 sq.mm.

30

24

745.8

... More
Above 185 sq.mm. and up to 400 sq.mm.

20

89

1796.6

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle

50

31

1564

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp

20

97

1957

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

20

145

2919.4

... More
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment

-

-

-

... More
3.5 x 300 sq.mm.

200

3220

644100

... More
3.5 x 240 sq.mm.

200

2635

527060

... More
3.5 x 185 sq.mm

20

2052

41059

... More
3 x 6 sq.mm,

350

201

70490

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
2 X 6 sq. mm (19mm)

32

158

5081.6

... More
3½ X 185 sq. mm (57mm)

2

563

1126.04

... More
3½ X 240 sq. mm (62mm)

4

648

2595.32

... More
3½ X 300 sq. mm (70mm)

4

750

3002.76

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required

-

-

-

... More
100 mm dia

10

1448

14484.5

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100mm dia

20

530

10618.8

... More
150 mm dia

20

580

11613.2

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

10

232

2325.9

... More
Providing and fixing HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required.

1

195

195.69

... More
Supplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.

4

1425

5700

... More
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.

2

2850

5700

... More
Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.

2

12350

24700

... More
Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.

2

8550

17100

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

10

14097

140978

... More
Supplying, installation & testing of 7.0 m high octagonal GI pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 150mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 2Cx6 sq.mm YWY cables and 2x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc.

12

28500

342000

... More
Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45Watt. to 50 Watt and Confirming to IP66 protection having Company LOGO Engraved complete in all respect with 4000-5000 system lumens High Power LED with lenses, 110lm/W, PF0.95, THD 10% at full load, CRI70, Avg Life Class 50000Hrs@L70,fitting itself suitable for 60-65mm OD pipe

12

5513

66165.6

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Double pole

12

445

5351.04

... More
Supply and fixing of LED Gate light fitting having die cast aluminium body and diffuser with driver set suitable for 6 watt to 10 watt. Confirming to IP 54 and above protection complete in all respect.

4

1237

4951.4

... More
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply

4

2932

11731.92

... More
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre

12

4302

51633.96

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required

-

-

-

... More
32 mm dia

20

259

5197

... More
EXT. FIRE FIGHTING FOR AUDITORIUM

-

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS)

-

-

-

... More
100 mm dia.

110

3325

365750

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
100 mm dia.

4

4860

19443.84

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
100 mm dia.

4

8056

32226.56

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :

-

-

-

... More
2 way - 100 mm dia M.S. Pipe (Siamese Connection)

4

4915

19662.56

... More
BORING & SUBMERSIBLE PUMP

-

-

-

... More
Transportation Charges of drilling equipment including assembly and other material as required.

1

19000

19000

... More
Drilling of 675 mm. dia by rotary machine

120

1425

171000

... More
Supply & laying of 350 mm. dia housing pipe (8 mm. thick)

50

2850

142500

... More
Supply & laying of 200 mm. dia blind pipe (8 mm. thick)

30

2375

71250

... More
Supply & laying of 200 mm. dia slotted pipe (8 mm. thick)

40

2375

95000

... More
Supply & fixing of 350 mm. dia Socket

8

1520

12160

... More
Supply & fixing of 200 mm. dia Socket

11

760

8360

... More
Supply & fixing of 200 mm. dia Bail plug

1

1235

1235

... More
Supply & fixing of 350 mm. dia well cap

1

2090

2090

... More
Supply & fixing of 350x200 mm. dia reducer.

1

5225

5225

... More
Supply & fixing of 350 mm. dia housing clamp

1

5700

5700

... More
Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I.

35

3420

119700

... More
Development by air compressor including Transportation.

30

2280

68400

... More
Development by O.P. Unit including Transportation.

40

1425

57000

... More
Supply of submersible pump suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition:

-

-

-

... More
A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm.

-

-

-

... More
B - Total Head of pump set 45 m.

1

59850

59850

... More
Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm.

60

171

10260

... More
Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set.

1

19000

19000

... More
Supply of 80mm dia M.S. column pipe of class 'C' both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements.

60

2850

171000

... More
Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc.

2

1330

2660

... More
Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make.

1

6175

6175

... More
Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.

2

9500

19000

... More
Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour.

1

1425

1425

... More
Supply of 80mm dia C.I. tee heavy quality i/c cost of material.

1

19000

19000

... More
Supply of Guru/Fibing or equivalent make pressure gauge.

1

11400

11400

... More
Erection & commissioning of pumping plants complete along with electric wiring.

1

14250

14250

... More
Supply of steel wire rope of 1/2" size

60

47

2850

... More
S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing.

1

5111

5111

... More
S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site.

8

190

1520

... More
S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm x 4 core

40

325

13034

... More
BOUNDARY WALL WITH RETAINING WALL - 2.0 MT.

-

-

-

... More
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.

915.35

123

113448.48

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

97.85

4756

465421.57

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

-

-

-

... More
Above plinth level

13.97

8033

112231.07

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

-

-

-

... More
Up to plinth level

237.47

6316

1499905.64

... More
Above plinth level

22.67

7578

171794.85

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size)

-

-

-

... More
R.C.C. Work in footing

279.58

6316

1765880.4

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

590.55

7530

4447213.55

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

48.64

4980

242231.58

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

117.22

6358

745311.72

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class -150 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

67.95

642

43652.44

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

67.95

73

4972.58

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand).

1509.21

239

362134.94

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Fabrication of grill / railing.

2851.87

152

436307.59

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

190.12

47

8947.05

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

190.12

108

20696.46

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

1509.21

119

180305.32

... More
Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work.

1509.21

108

164443.52

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick.

121.47

587

71411

... More
Foundations, footings, bases of columns, etc. for mass concrete.

215.06

273

58887.73

... More
Columns,Pillars, Piers, Abutments, Posts and Struts.

2140.53

671

1436787.95

... More
BOUNDARY WALL WITH RET. WALL - 5.36 MT. DEPTH

-

-

-

... More
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.

1008.8

123

125030.67

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

90.12

4756

428653.98

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).Above plinth level

9.2

8033

73910.22

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

-

-

-

... More
Up to plinth level

555.71

6316

3509969.94

... More
Above plinth level

14.93

7578

113140.59

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size) R.C.C. Work in footing

427.58

6316

2700676.52

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

1128.6

7530

8499069.02

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

44.93

4980

223755.44

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

77.2

6358

490855.36

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class -150 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

44.75

642

28748.3

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

44.75

73

3274.81

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand).

993.97

239

238503.1

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Fabrication of grill / railing.

1878.25

152

287353.47

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

125.22

47

5892.85

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

125.22

108

13631.45

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

993.97

119

118749.6

... More
Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work.

993.97

108

108302.97

... More
Geosynthetic Drainage with two filtering nonwoven geotextiles having a “W” configuration as longitudinal parallel channels. Minimum thickness to be 7.2 mm, with two filtering UV stabilized polypropylene nonwoven geotextile of minimum thickness of 0.75 mm having pores of 150 micron and tensile strength of 8.0 kN/m and having plane flow capacity of 2.1 L / (m.s) at hydraulic gradient of 1.0 & 20 kPa pressure,tensile strength of 18 kN/m , with mass per unit area of 740 gsm.

128.82

425

54778.13

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick.

80

587

47031.2

... More
Foundations, footings, bases of columns, etc. for mass concrete.

236.07

273

64640.69

... More
Columns,Pillars, Piers, Abutments, Posts and Struts.

3007.95

671

2019026.28

... More
6.0 MT. WIDE M.S. GATE (2 Nos.)

-

-

-

... More
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.

13.84

123

1715.33

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 fine sand :8 graded stone ballast 40 mm nominal size) and curing complete, including cost of form-work,in foundation and floors.

1.74

4756

8276.28

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3 in R.C.C. Footing excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-200.

3.04

6316

19201.22

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3 in Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-200. Up to plinth lvl.

0.55

6316

3473.9

... More
As in item 3 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-150.

-

-

-

... More
Up to plinth lvl.

3.25

6316

20527.62

... More
Above plinth lvl.

2.92

7578

22127.96

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

13.69

7530

103094.32

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand).

25.92

239

6219.5

... More
Finishing walls with water-proofing on cement paint of approved make such as super snowcem, durrocem, robiacem, guttucem supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white cement primer to give an even shade after thoroughly brushing the surface to powdered materials including curing and cost of all materials.

25.92

119

3096.66

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1267.2

108

138074.11

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

57.6

47

2710.66

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

57.6

108

6270.34

... More
Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

1267.2

152

193868.93

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick.

4.8

587

2821.87

... More
Columns,Pillars, Piers, Abutments, Posts and Struts.

54.81

671

36790.12

... More
Foundations, footings, bases of columns, etc. for mass concrete.

8.1

273

2217.94

... More
GATE COMPLEX WITH GUARD ROOM (CIVIL WORK)

-

-

-

... More
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.

42.47

123

5263.73

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone ballast 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

8.18

4756

38908.01

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156]

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

8.2

7000

57401.89

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab)

26.21

6751

176967.3

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam)

20.3

6751

137063.57

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column)

-

-

-

... More
Same as above for ground floor (Up to Plinth level)

11.58

7000

81062.66

... More
Same as above for ground floor (Above Plinth level)

28.72

6751

193914.57

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing)

8.57

7000

59991.97

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

7.76

4980

38645.5

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

52.86

6358

336096.04

... More
Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

2886

152

441529.14

... More
Steel Painting:

-

-

-

... More
(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

44.4

47

2089.46

... More
(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

44.4

108

4833.38

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

138.28

7530

1041335.52

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - Exposed face fine dressed with rough backing.60 mm thick

455.56

4214

1919971.29

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.

455.56

498

227246.99

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.

47.55

428

20392.77

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work.

46.37

129

6010.94

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

46.37

108

5052.48

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

2.7

765

2067.31

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

12.29

885

10880.95

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

35.75

239

8578.21

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

3.68

1670

6148.07

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

-

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

10.8

98

1068.55

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding

21.6

152

3304.58

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

195.84

91

17921.32

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

-

-

-

... More
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

35.85

136

4886.36

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

16.8

273

4600.18

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick.

154.31

718

110806.92

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

162.35

587

95443.94

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

354.29

671

237810.08

... More
GATE COMPLEX WITH GUARD ROOM (PLUMBING WORK)

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:

-

-

-

... More
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

4725

4725.34

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:

-

-

-

... More
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

1

1554

1554.55

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

1

722

722.55

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

1

161

161.96

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

1

77

77.82

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

1

1122

1122.75

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink)

-

-

-

... More
15 mm nominal bore

2

401

802

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :

-

-

-

... More
45 cm length

-

-

-

... More
15 mm nominal bore

2

68

136.5

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15mm nominal bore

1

353

353.87

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
For Internal Toilet

-

-

-

... More
15 mm nominal outer dia Pipes

2.88

347

1001.06

... More
20 mm nominal outer dia Pipes

6.6

375

2477.51

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm nominal bore

14.96

233

3499.29

... More
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall

-

-

-

... More
Terrace loop & Tank Filling Pipe

-

-

-

... More
25 mm nominal bore

27.5

385

10593.55

... More
Providing , checking, storing, fixing in position of approved quality Screwed ends Brass float valve with brass ball float and PTFE seat suitable for Body test pressure of 15Kg/sqcm of the following sizes:

-

-

-

... More
25mm

1

1843

1843

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :

-

-

-

... More
25mm diameter pipe

27.5

21

580.8

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :

-

-

-

... More
25 to 40 mm nominal bore

1

636

636.73

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
For vertical pipe connection with terrace ringmain

-

-

-

... More
20 mm nominal bore

1

377

377.02

... More
25mm nominal bore

1

434

434.59

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

250

7

1920

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
110 mm dia (for rain water)

18

263

4743.36

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single Push Fit Coupler

-

-

-

... More
110 mm dia

4.8

89

427.68

... More
Single tee with door

-

-

-

... More
110x110x110 mm

2

163

327

... More
Plain bend 87.5 deg

-

-

-

... More
110 mm dia

4

104

419.92

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
110 mm dia

7.2

259

1866.67

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

2

208

416.5

... More
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.

-

-

-

... More
Internal Toilet (Soil & Waste Pipe)

-

-

-

... More
75 mm

6.6

479

3166.35

... More
110 mm

7.92

679

5379.66

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
Bend without door (45°)

-

-

-

... More
75mm

1

128

128.25

... More
Y' Fitting without door

-

-

-

... More
75mm

1

218

218.5

... More
Single Tee without door

-

-

-

... More
75 mm

1

213

213.75

... More
Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.

-

-

-

... More
For Wash basin & Urinal

-

-

-

... More
32mm dia. Pipe (for wash basin & sunken toilet spout)

3.08

175

541.31

... More
Elbow (90°)

-

-

-

... More
32mm

1

38

38

... More
Elbow (45°)

-

-

-

... More
32mm

1

42

42.75

... More
T fitting

-

-

-

... More
32mm

1

42

42.75

... More
Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm x 50mm/40mm (Toilet)

1

1159

1159

... More
Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
Rectangular type with openable circular lid

-

-

-

... More
150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)

1

137

137.52

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :

-

-

-

... More
150 x 100mm size P-type

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

1909

1909.16

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:

-

-

-

... More
100 mm diameter

3

309

929.22

... More
Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.

-

-

-

... More
All kind of soil

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

6

245

1475.34

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:

-

-

-

... More
100mm dia SW pipe

6

673

4041.84

... More
GATE COMPLEX WITH GUARD ROOM (ELECTRIFICATION WORK)

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

10

1176

11765.6

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

60

186

11212.2

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

66

267

17679.42

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.

1

382

382.56

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

1

469

469.98

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required

1

295

295.94

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

2

32

64.16

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

3

69

209.34

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

8

95

763.52

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

1

176

176.97

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required

-

-

-

... More
Upto 450 mm sweep

1

360

360.91

... More
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.

1

166

166.02

... More
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).

2

1510

3021

... More
Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.

2

1470

2941.2

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan

1

2189

2189.51

... More
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN

1

2280

2280.95

... More
Supply, Installation, Testing and Commissioning of LED RGB/RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270V AC, 50Hz with power factor0.9. Fixtureshallbesuitabletooperateatanambienttemperaturerangeof-10°Cto+50°CandshallbeIP65andIK06rated.LifetimeshallbeatleastL70:50000burninghoursat50°C.LuminaireshallbeconformingtoBIS(IS10322)andshallbecompletewithallnecessaryaccessoriesrequiredforproperworkingoffixtureincludingweatherproofconnectioncables,waterproofconnectorsetc. as required.45W /40W

4

29867

119468.68

... More
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door

1

2063

2063.59

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

4

205

821.28

... More
Double pole

1

526

526.12

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

2

10

20.86

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

1

215

215.74

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

1

5992

5992.68

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

45

115

5197.05

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

10

230

2301.8

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

30

195

5870.7

... More
Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:

-

-

-

... More
2 Pair (4 core)

48

30

1463.04

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm dia PVC conduit

10

102

1026.6

... More
25mm dia PVC conduit

20

116

2325.8

... More
32mm dia PVC conduit

10

147

1475.7

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required

-

-

-

... More
1 or 2 Module (75mmX75mm)

1

239

239

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

-

-

-

... More
Telephone socket outlet

1

118

118.7

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm.

80

310

24830.4

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required

-

-

-

... More
Up to 35 sq.mm.

10

29

296.7

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle

10

44

441.1

... More
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment

-

-

-

... More
2 x 10 sq.mm,

100

235

23560

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
2 X 10 sq. mm (19mm)

2

193

386.58

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100mm dia

5

530

2654.7

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

5

232

1162.95

... More
75 K.L. FIRE & DOMESTIC U.G. WATER STORAGE TANK

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

-

-

-

... More
0.0 TO 1.50 Mtr

125.76

123

15586.69

... More
1.50 TO 3.0 Mtr

124.88

212

26534.5

... More
3.0 TO 4.50 Mtr

124.88

301

37591.38

... More
4.50 TO 6.00 Mtr

36.5

389

14218.58

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

8.51

4756

40477.64

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Lintel)

0.16

6914

1106.38

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Beam)

1.36

6914

9404.26

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Slab)

14.13

6914

97707.54

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Footing)

32.27

6914

223143.82

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (R.C.C. Wall/Column)

59.13

6914

408878.04

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

107.78

7530

811651.3

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

9.12

6358

57987.06

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)

25.63

239

6149.92

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand)

50

276

13802.5

... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster

243.27

410

99743.13

... More
Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick

2.52

1516

3822.01

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

-

-

-

... More
Providing & fixing of hold fast for chaukhats of doors and windows.

8.4

67

570.11

... More
Providing & fixing of door / windows grill.

43.2

120

5206.46

... More
Z-Section steel windows

48.96

89

4384.37

... More
Angle iron door chaukhat 40*40*5

16.2

91

1476.14

... More
Fixing of Door, windows/ventilators chaukhats in position.

-

-

-

... More
Door

1

142

142.5

... More
Window

2

95

190

... More
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface)

25.63

129

3322.42

... More
Finishing walls with water-proofing on cement paint of approved make such as super snowcem, durrocem, robiacem, guttucem, supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white cement primer to give an even shade after thoroughly brushing the surface to powdered materials including curing and cost of all materials.

50

81

4081.5

... More
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Ceiling)

10.88

129

1410.37

... More
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :

-

-

-

... More
(a) 250 mm x 10mm

1

58

58.58

... More
(a) 200 mm x 10mm

1

48

48.46

... More
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm

2

27

55.8

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

7.27

157

1148.51

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

5.04

157

796.22

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to

-

-

-

... More
IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick

-

-

-

... More
jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including l

6.47

1176

7610.47

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.

-

-

-

... More
iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)

341.44

537

183479.61

... More
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

340.4

270

92221.17

... More
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade

243.27

776

189006.19

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete40 mm thick with 20 mm nominal size stone aggregate,

13.56

428

5815.48

... More
Centering and shuttering including strutting, propping etc. and removal of form for:

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platform.

69.35

647

44900.66

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers.

17.65

514

9075.45

... More
Columns, Pillars, Piers, Abutments, Posts and Struts.

352.77

671

236789.81

... More
PUMP ROOM (ELECTRIFICATION WORKS

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

2

1069

2139.2

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

10

169

1698.8

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

2

63

126.86

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

1

86

86.76

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as requiredUpto 450 mm sweep

1

328

328.1

... More
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.

1

150

150.93

... More
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).

1

325

325.85

... More
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN

1

1391

1391.75

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

22089.2

489

10804269.5

... More
SUBHEAD - V :D.G. SETS

-

-

-

... More
Supplying, Installation and commissioning of AMF start silent type 225 KVA DG set comprising of suitable BHP diesel engine directly coupled to 3 phase 50 Hz 415 V alternator of 225 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per

-

-

-

... More
CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms

-

-

-

... More
AMF Panel Incoming-630 Amps FP MCCB of 35KA breaking capacity and contactor same rating

1

2494206

2494206

... More
FURNITURE

-

-

-

... More
ARISTO TABLE 2100 LH RU 1200 PDL 2100x2250x750 All specification as per standard & detailed estimate.

1

105222

105222

... More
ACE WITH HEADREST CHAIR Active Bio-Synchro Mech,Bio-Flex Lumbar Support, Seat Slide Mech, Die cast polished Aluminum Pedestal, Adj Arms, 5 Position Tilt Limiter. All specification as per standard & detailed estimate.

-

-

-

... More
(a) ACE Full Back

1

18748

18748

... More
(b) Headrest

1

1554

1554

... More
ACE - Visitor Chair Bio-Flex Lumber Support, MS Powder Coated U/S, Adj Arms. All specification as per standard & detailed estimate.

3

12974

38922

... More
PARTO Pl 3Str Sofa SLthr Blk Overall Size : Width : 175cm Depth : 87cm Height : 76cm Seating Height : 39.5cm. All specification as per standard & detailed estimate.

1

30965

30965

... More
Bloom Coffee Table Walnut Overall Size : Width: 100cm Depth : 65cm Height : 43cm. All specification as per standard & detailed estimate.

1

22718

22718

... More
Adriana Single Bed Walnut Overall Size : Length : 206cm Width : 113.1cm Bed Height : 41cm Bed with Headboard Height : 93cm, All specification as per standard & detailed estimate.

5

24202

121010

... More
Ortho Plus Mattress 78 36 4 Thickness: 10 cm / 12.5 cm, All specification as per standard & detailed estimate.

5

9937

49685

... More
Pillow Nice L:425mm W:675mm Size ( in cm) : 43 x 69, All specification as per standard & detailed estimate.

5

627

3135

... More
Manager Module Workstation, All specification as per standard & detailed estimate.

8

79560

636480

... More
PULSE Mb Seat Chair, Adj. Arms Larger Seats Lumber Pad, Adj Seat Height, Back tilt Tension,Recline Lock, Nylon Pedestal, KTS Mechanism 4 Positon Locking, All specification as per standard & detailed estimate.

8

10888

87104

... More
ECHO HDU size : 900 X 740 X 450, All specification as per standard & detailed estimate.

3

14956

44868

... More
Grande 4 Seater, All specification as per standard & detailed estimate.

16

24426

390816

... More
Grande Dining chair, All specification as per standard & detailed estimate.

64

6262

400768

... More
Squadro V2 King Bed Cinmon Overall Size : Length : 205.3cm Width : 187.5cm Bed Height : 42.3 Bed with Headboard Height :113.3cm, All specification as per standard & detailed estimate.

4

59288

237152

... More
Squadro Bedside Table Cinnamon Overall Size : Width : 61cm Depth : 45.5cm Height : 50.35cm, All specification as per standard & detailed estimate.

8

9921

79368

... More
Accupadic Mattress 78 72 5 Thickness: 12.5 cm / 15 cm, All specification as per standard & detailed estimate.

4

24978

99912

... More
Orlando P 1str sofa Plthr Brwn Overall Size : Width : 92cm Depth : 92cm Height : 89cm Seating Height : 47.5cm, All specification as per standard & detailed estimate.

10

43815

438150

... More
Bloom Corner Table Walnut Overall Size : Width : 60cm Depth : 60cm Height : 45cm, All specification as per standard & detailed estimate.

4

14793

59172

... More
Nebula sofa 3+1+1 Nebula V3 1str Sofa fab Grey Overall Size : Width : 101cm Depth : 97.5cm Height : 93cm Seating Height : 46cm, All specification as per standard & detailed estimate.

1

29894

29894

... More
Nebula V3 3str Sofa fab Grey Overall Size : Width : 231cm Depth : 97.5cm Height : 93cm Seating Height : 46cm, All specification as per standard & detailed estimate.

1

61455

61455

... More
Arbor coffee table in Remini Walnut Dimensions W x H x D (cm)-120 x 45 x 60, All specification as per standard & detailed estimate.

1

9999

9999

... More
Arbor side table in Remini Walnut Dimensions W x H x D (cm)-80 x 45 x 37.5, All specification as per standard & detailed estimate.

1

7483

7483

... More
Elixir DinTable 4Str Marble Overall Size : Width : 136cm Depth : 136cm Height : 78.5cm, All specification as per standard & detailed estimate.

1

73877

73877

... More
Opulent Adv Dining Chair Beige Overall Size : Width : 33.5cm Depth : 43.5cm Height : 88.5cm, All specification as per standard & detailed estimate.

4

10539

42156

... More
MERAKI Media Unit Brn/Beige Overall Size : Width : 180.4cm Depth : 49.5cm Height : 50.4cm, All specification as per standard & detailed estimate.

4

37453

149812

... More
CIGNUS TABLE 1650 LH RU 1200 PDL 1650x1950x750, All specification as per standard & detailed estimate.

1

84178

84178

... More
PULSE CHAIR WITH HEADREST Adj Neck rest & lumber Pad, Seat Height, Back tilt Tension,Recline Lock, Nylon Pedestal, KTS Mechanism 4 Positon Locking , All specification as per standard & detailed estimate.

-

-

-

... More
(a) Mb Seat, Adj. Arms Larger Seats , All specification as per standard & detailed estimate.

1

10888

10888

... More
(b) Neck Rest Adj. Chair, All specification as per standard & detailed estimate.

1

1012

1012

... More
OXBO - Visitor Fixed PP Arms,Tubular frame structure, All specification as per standard & detailed estimate.

3

6253

18759

... More
Upbeat 8 seater, All specification as per standard & detailed estimate.

3

58500

175500

... More
OXBO - Mid Back chair CT Mech Upright Position Locking, Fixed PP Arms, Nylon Ped, All specification as per standard & detailed estimate.

24

7560

181440

... More
RDNC SR1 MTL SW 1200mm 300mm 1200W X 300D X 2078H, All specification as per standard & detailed estimate.

6

20791

124746

... More
RDNC DR1 MTL SW 1200mm 600mm 1200W X 600D X 2078H, All specification as per standard & detailed estimate.

6

33766

202596

... More
MINGLE MODULAR MEETING TABLE PLT(90 SEATER), All specification as per standard & detailed estimate.

90

15760

1418400

... More
BEAT (LC) - High Back Chair With Seat Slide KTS Mech 4 Position Locking, Chrome Pedestal, Chrome-platting element in PU-up-down adj arms & Ht. Adj Backrest, All specification as per standard & detailed estimate.

2

16182

32364

... More
BEAT (LC) - Mid Back Chair With Seat Slide KTS Mech 4 Position Locking, Chrome Pedestal, Chrome-platting element in PU-up-down adj arms & Ht. Adj Backrest, All specification as per standard & detailed estimate.

96

15178

1457088

... More
Majesta P 2Str sofa Leather Ch Overall Size : Width : 1520mm Depth : 840mm Height : 760mm, All specification as per standard & detailed estimate.

2

58298

116596

... More
Majesta P 3Str sofa Leather Ch Overall Size : Width : 1820mm Depth : 840mm Height : 760mm, All specification as per standard & detailed estimate.

3

77730

233190

... More
Meraki coffee table Brow/Beige Overall Size : Width : 120cm Depth : 60cm Height : 36.7cm, All specification as per standard & detailed estimate.

2

16436

32872

... More
Meraki corner table Brown Overall Size : Width : 60cm Depth : 60cm Height : 49.8cm(With Bush), All specification as per standard & detailed estimate.

6

4982

29892

... More
LIFT FOR GUEST HOUSE

-

-

-

... More
LIFT with power operated centre opening doors and AC variable voltage & variable frequency controls (travel height G+4) 8 PASSENGERS CAPCITY, All specification as per standard & work execution as per detailed estimate.

1

1267140

1267140

... More
GST Extra as applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.