Uttar Pradesh Power Transmission Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date16 Mar 2024
Closing DateCancelled
Tender Amount₹ 74,41,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth filling under floors and/or sub station area including cost of earth when obtained from with in 8 km outside UPPCL area including its roylty and carriage including watering, ramming in 20 cm layers and dressing of earth etc. all complete. (CSI No. 4.10)

90

39240

436

... More
Concrete with 4cm gauge stone ballast, coarse sand & cement in proportion of 12:6:1 in foundations &under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No. 5.02)

23

133860

5820

... More
Concrete with 4cm gauge stone ballast, coarse sand and cement in proportion of 8:4:1 in foundation & under floors including supply of all materials, labour & T&P etc. complete. (CSI no. 5.04a)

11

68508

6228

... More
Cement concrete with 2cm gauge approved hard stone ballast, coarse sand and cement in proportion of 4:2:1 including supply of all materials, labour,side shuttering if required and T&P etc. required for proper completion of work. (CSI No. 5.06)

10

75200

7520

... More
Concreting of 40 mm thick RCC trench covers in mild steel frame work with RCC 1:1.5:3 in Cement, coarse sand and 2cm gauge graded hard stone ballast with 3mm thick floating coat of neat cement finish on top of cover complete with all labour, materials and placing the same in proper position at required location of cable trench within the substation area. (CSI No. 5.18)

60

22380

373

... More
Cement concrete with 2cm gauge approved hard stone ballast, coarse sand and cement in proportion of 3:1.5:1 including supply of all materials, labour,side shuttering if required and T&P etc. required for proper completion of work (CSI No. 5.21)

12

95868

7989

... More
Precast cement concrete door sills, chaukhats boundary posts, shelves and similar small work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast in the proportion 1:1.5:3, excluding reinforcement but including fixig the same in position including cost of all other material, labour and T&P . (CSI No. 5.22)

1

9550

9550

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in lintels of doors and windows, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. (CSI No. 5.23)

11

101255

9205

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in slab, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P (CSI No. 5.24)

30

318000

10600

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in lighter beams i.e. having span upto 6m, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . (CSI No. 5.25)

15

172095

11473

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in raft foundation and footings , excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. (CSI No. 5.27)

28

246428

8801

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in RCC T beam-slab and column, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . (CSI No. 5.29)

20

232940

11647

... More
First class brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour & T&P etc. required for proper completion of work (CSI No. 6.03)

60

325200

5420

... More
First class brick work in 1:6 cement and coarse sand mortar in superstructure including necessary cutting & moulding of bricks as required for one brick thick wall including supply of all materials, labour & T&P etc. required for proper completion of work. including extra labour. ( CSI 6.01+6.07+6.08)

80

473680

5921

... More
First class brick work in 1:4 cement and coarse sand mortar in superstructure including necessary cutting & moulding of bricks as required for half brick (115mm) thickness wall including supply of all materials, labour & T&P etc. required for proper completion of work.including extra labour (CSI 6.03+6.07+6.09)

10

62800

6280

... More
S/Fixing of double action floor springs including cutting in floors / RCC slabs and grouting the same with C.C. & finishing the surface properly as and where required under aluminium doors as per direction of Engineer-in-charge. including cost of all other material, labour, tools & plants etc. complete. (CSI No. 8.52)

8

80128

10016

... More
Supply and fixing brass polished hydraulic door closure of approved make & quality its fixing and adjustment with the help of screws, nuts and bolts including supply of all labour, T & P etc. required for proper completion of the work. (CSI No. 8.57)

8

12472

1559

... More
Supply and fixing Anodized Aluminium Door fittings like 2 no 150 mm handles,2 no 250 mm tower bolt, 1 no stopper and 1 no 12 mm belan including all materials, labour & T&P etc. required for proper completion of work.(CSI No. 8.58)

10

4370

437

... More
Supply and fixing Anodized Aluminium Window fittings like 2 no 100 mm handles,2 no 150 mm tower bolt, 1 no stopper including all materials, labour & T&P etc. required for proper completion of work. (CSI No. 8.59)

10

2230

223

... More
Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor. (CSI No. 9.01)

1.5

148596

99064

... More
Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials when steel is to be provided by the department(CSI No. 9.02)

0.5

16367

32734

... More
TMT/Tor steel in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage, bend, hooks and authorized overlapping shall be measured. (Steel shall be arranged by the contractor)(CSI No. 9.03)

11.5

1012782

88068

... More
Supplying and fixing rolling shutters of approved make made of 80x1.25 mm. Gauge cold rolled M.S. lathes inter locked through out their inner length and joined together at the end by end lock guides & arrangements for inside and outside locking with push &pull operation complete but excluding the cost of top cover and springs. CSI No. 9.08)

18

41598

2311

... More
P/F 27.5cm. long wire spring grades 2 for rolling shutters. (CSI No. 9.09)

4

2024

506

... More
Providing and fixing top cover rolling shutters. (CSI No. 9.10)

10

5030

503

... More
Providing & fixing ball bearing for rolling shutters. (CSI No. 9.11)

4

2244

561

... More
Supply and fixing galvanised mosquito proof jali (16x24 gauge) with M.S. flat of 20 x 3 mm. size, on both sides screwed or welded to window or door frame. (CSI No. 9.18)

30

21870

729

... More
Providing M.S. Frames work, rack etc for R.C.C. Trench covers and edging with M.S. angles and M.S reinforcement including cutting, bending and welding as per approved drawing. The rate is including cost of all labour, materials etc. as required for proper completion of the work. (CSI No. 9.20)

4

385608

96402

... More
Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) . (CSI No. 9.30)

250

3250

13

... More
Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only).(CSI No. 9.33)

450

4950

11

... More
6 mm thick Chequered plate trench covers with 40 x 40 x 5 angle support on two sides across the trench section and 12mm dia rectangular reinforcement hook complete with all labour, materials, welding and cutting etc including all T&P required. (CSI No 9.41 )

25

115975

4639

... More
12 mm thick plaster with cement mortar consisting of one part of cement & four part of coarse sand (1:4), minimum thickness not to be less then 10 mm including supply of all material, labour and T&P etc for proper completion of work. (CSI No. 11.07)

1400

277200

198

... More
Add for extra labour to all items of plaster if done in ceiling. (CSI No. 11.10)

150

3210

21.4

... More
Add for extra labour and materials for plaster over rough face of one brick thick wall. (CSI No. 11.12)

500

13000

26

... More
S/mixing approved water proofing compound (CICO,DR FIXIT etc) in cement mortar in plaster or concrete work in the proportion as recommended by the manufacturer.(CSI No. 11.15)

125

5875

47

... More
Providing (12x15) mm section groove in plaster including all material, labour and T&P etc. required for proper completion of the work. (CSI No. 11.16)

300

3600

12

... More
Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. (CSI No.11.18)

250

2250

9

... More
Making drip coarse (25x12) mm in 1:2 cement and coarse sand including supply of all materials, labour and T&P etc required for proper completion of work.(CSI No. 11.19)

150

1800

12

... More
2.5 cm thick 1:2:4 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC (CSI No. 12.02)

50

14050

281

... More
4.0 cm thick 1:2:4 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC (CSI No. 12.04)

90

38700

430

... More
First class bricks on edge floor laid dry, joints sand filled, including preparation of base to proper slope and its ramming including supply of all material labour & T&P etc. required for proper completion of the work. (CSI No. 12.07)

120

69960

583

... More
Providing and fixing glass strips of 3.15 mm thickness & 40mm depth in joints of floor and skirting at the time of laying floors, flush with floor level including supply of all materials, labour& T&P etc. required for proper completion of work. (CSI No. 12.14)

90

2970

33

... More
Providing and laying floor of 8 mm thick vitrified tiles in flooring or skirting of approved brand (Bell, Johnson or equi. make) size of 600x600 mm of approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cement mixed with pigment to match the shade of tile including cost of all material, labour and T&P required for proper completion of the work. (CSI No. 12.18)

120

161640

1347

... More
Providing and laying of 16 mm thick granite ( black/ brown) in flooring or skirting ,of approved shade, colour,size and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cement mixed with pigment to match the shade of granite floor including cost of all material, labour and T&P required for proper completion of the work, as per direction of Engineer incharge. (CSI No.12.20)

30

105000

3500

... More
Supply of 80 mm thick I shaped mechanically compressed inter locking cement concrete paver block manufactured by high pressure & controlled vibration machine having plan dimension 200X(160+120 mm) with minimum 5 mm thick toping of O.P.Cement mixed with 25% marble powder. The compressive strength of concrete pavers blocks shall not be less than 30 MPa & 4.5 Kg/No. including cost of all material, labour, T&P etc. required for proper completion of work as directed by Engineer-in-charge but excluding G.S.T. which shall be paid extra as per rules. (CSI No.12.23)

50

51850

1037

... More
Painting or varnishing new iron work in small areas or new wood work with one coat of ready mixed priming paint and one coat of approved superior quality ready mix paint "Luxol" or equivalent brand or varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should conform to the I.S. 103-1950.(CSI No. 13.01)

200

15400

77

... More
Painting every coat after first coat of approved superior quality ready mix paint "Luxol" or equivalent brand or varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should conform to the I.S. 103-1950 (CSI No. 13.02)

200

7200

36

... More
One priming coat and one coat oil bound distemper on new work including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 13.08)

900

62100

69

... More
Every coat after first Coat of oil bound distemper including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 13.09)

900

25200

28

... More
Applying Birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ICI or equivalent brand for smoothening and levelling of the surface as per requirement and direction of Engineer I/C including cost of all material, labour, T & P etc required for proper completion of work. (CSI No. 13.20)

1200

106800

89

... More
Applying BIRLA PUTTY or equivalent putty on previousaly birla putty smoothen surface over one cost of water base cement primer of ICI or equivalent brand for smoothining and leveling of the surface as per requirement and direction of E/I including cost of all material , labour and T&P required for proper completion of work.(CSI No.13.21)

400

17200

43

... More
Painting one coat with APEX or equivalent brand weather coat paint on new wall surfaces (well prepared with Birla putty and one coat of primer ICI or equivalent which shall be paid separately) including through washing with water including cost of all materials, labour, T&P required for proper completion of work. (CSI No. 13.22)

700

68600

98

... More
Painting every coat after first coat with APEX or equivalent brand weather coat paint on including through washing with water including cost of all materials, labour, T&P required for proper completion of work. (CSI No. 13.23)

700

30800

44

... More
Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metres.(CSI No. 15.01)

10

5830

583

... More
Dismantling reinforced cement concrete or reinforced brick work, including stacking of dismantled materials as directed by the Engineer-Incharge within a distance of 60 metres. (CSI No. 15.03)

10

12930

1293

... More
Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer In-charge within a distance of 60 metres. (CSI No. 15.05)

30

2010

67

... More
Dismantling doors or window leaves including stacking of materials as directed by the Engineer I/C within a dist. 60 M. (CSI No. 15.09)

20

700

35

... More
Dismantaling doors and windows chowkhats including stacking of materials as directed by Engg-in-Charge within a distance of 60 meters. (CSI No. 15.10)

22

1628

74

... More
Dismantling existing plaster including disposal of refuse as directed by the Engineer-I/C within a distance of 60 M. (CSI No. 15.11)

150

7050

47

... More
Scrapping old white or colour wash or distemper including disposal of refuse as directed by the Engineer-I/C within a distance of 60 M. (CSI No. 15.12)

400

6000

15

... More
Dismantling of existing R.C.C. Gantry/ Auxiliary foundation with the help of mechanical means in switchyard including disposal of refuse/ debris as per direction of Engineer - in - charge. Including all labour and T&P etc. required for proper completion of the work. (CSI No. 15.15)

2

4174

2087

... More
Laying cement concrete road slab in 1:1.5:3 consisting of 1 part cement 1.5part approved coarse sand and 3 part approved 20mm down graded stone aggregate over prepared sub grade after its rectification and bringing it to proper camber and shape,finishing with TRIMIX machine ,concrete hardner and making good to the satisfaction of E/I inclduing cost of all materials, labour and T&P etc. required for proper completion of the work . (CSI No. 18.13)

18

166158

9231

... More
Providing and fixing 12mm thick particle board of commercial quality 125 mm deep for making partitions of C.C. road slab as per direction of E/I. including cost of all material, labour and T&P required for proper completion of work. (CSI No. 18.15)

20

3580

179

... More
Providing and fixing of 110 mm dia PVC pipe 6 Kg/ Sq.cm for with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.17)

40

11760

294

... More
Applying two coat Tapcrete mixed with White Cement and water to proper consistany on leaky surface including supply of all materials, labour etc. required for proper completion of work. (CSI No. 28.16)

200

23200

116

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (CSI No. 28.22)

100

72300

723

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) (CSI No. 28.24)

120

60720

506

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester Powder coated aluminium (minimum thickness of powder coating 50 micron) (CSI No. 28.25)

50

28600

572

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (CSI No. 28.27)

250

27750

111

... More
Providing and fixing false ceiling at all heights with integral densifiedr Armstrong false ceiling tiles of Size 595x595 x12 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as perBS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 SUB HEAD : 26- NEW TECHNOLOGIES AND MATERIALS 1632 mm reveal profile white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 26.23.1 With 12 mm thick Armstrong Miniral Fobre Sound Absorbing Sheet (CSI No. 28.30)

100

142400

1424

... More
Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With ACP of 4.0 mm thickness.(CSI No. 28.31)

10

17150

1715

... More
Supply and Installation in complete respect of 1.5 Ton Split AC 5 star (O General, Hitachi, Daikin make ) along with 5 KVA V Guard or equivalent make stabilizers, stands, drain pipes etc including all labour and T&P and all related works as required for proper installation and running of the system complete in all respects as approved by Engineer In Charge. (CSI No. 28.36)

17

861135

50655

... More
Wiring point for light with 1.5 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe concealed in the wall, with 1.5 sq.mm.FRLSH PVC multistrained copper conductor cable as earthwire drawn inside the conduit,modular type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite sheet etc,complete in all respects,as directed,including matching colour wash. (PWD ELE. SCH.2018,131C+187A)

60

41220

687

... More
Wiring point for fan/fresh air fan with 1.5 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe concealed in the wall, with 1.5 sq.mm.FRLSH PVC multistrained copper conductor cable as earthwire drawn inside the conduit,modular type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite sheet etc,complete in all respects,as directed,including matching colour wash (PWD ELE. SCH.2018,133C+187A)

20

15040

752

... More
Wiring point for plug with 1.5 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe concealed in the wall, with 1.5 sq.mm.FRLSH PVC multistrained copper conductor cable as earthwire drawn inside the conduit,modular type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite sheet etc,complete in all respects,as directed,including matching colour wash. (PWD ELE. SCH.2018,134C+187C)

30

12540

418

... More
Wiring point for exhaust fan with 1.5 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe concealed in the wall, with 1.5 sq.mm.FRLSH PVC multistrained copper conductor cable as earthwire drawn inside the conduit,modular type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite sheet etc,complete in all respects,as directed,including matching colour was.(PWD ELE. SCH.2018,137C+187D)

6

5682

947

... More
Supply and fixing and concealing of 25 mm dia 2 mm thick PVC conduit pipe with ISI marked embossed and with PVC accessories confirming to IS 3419 for drawing wires duly sealed at joints original resin/adhesive to make the complete piping rigid, plastering with cement sand mortor finished to the level with matching colour wash including cost of all materials, labour and T&P etc.required for proper completion of the work(PWD ELE. SCH.2018,148A) but for 25 mm dia 2 mm thick PVC conduit(PWD ELE. SCH.2018,149A)

150

10800

72

... More
Supply and fixing of 2/3/4 ways round steel junction box confirming to ISS for 25mm dia 16 guage (1.5mm) thick rigid steel conduit concealed in wall, keeping its level upto plaster duly provided with proper size cover screwed as directed at site by Engineer-in-charge with supply of all material, labour & T&P etc. required for proper completion of work. (PWD ELE. SCH.2018,155)

45

1800

40

... More
Supply and fixing of 32 Amp.240 V DP metal clad rewireable type switch fuse unit on MDFEG/Teak wood board including making connections etc.complete all respect.(PWD ELE. SCH.2018,305 CAT-B)

36

51840

1440

... More
Supply and burying of 600 x 600 x 3 mm copper plate vertically for earthing with its top at least 3 mtr. below ground level complete with 20 mm dia G.I. Pipe and funnel for watering and one earthing lead of one no. 8 to 10 S.W.G. copper wire in 15 mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. Pipe and copper wire will be extra) 30 cm sq. C.I. frame with hinged cover masonary housing alternate layer of charcoal /coke & salt at least 150 mm thick alround etc.complete in all respects.(PWD ELE. SCH.2018,704)

4

40680

10170

... More
S/F of one number 8 SWG G.I. wire in 15mm dia G.I.pipe for earthing,laid in ground or in wall duly concealed including the cost of cement,sand,labour,T&P and other materials, labour and T&P etc.required for proper completion of the work.(PWD ELE. SCH.2018,721)

20

4000

200

... More
S&F of 6 Amp to 32 Amp. SP MCB (10 KA) C Curve CAT-A (PWD SOR-No. 1002)

20

5200

260

... More
S/F of 63 Amp DP Isolator.(CAT-A) (PWD SOR No. 1005B)

6

3570

595

... More
S/F surface/flush mounting 4 ways SPN distribution board without MCB with additional metal door complete in all respect as per direction of E/I. (PWD ELE. SCH.2018,1022 CAT-B)

100

91000

910

... More
Supply and fixing of power plug with 20 amp/250 volt flush type modular switch and 5pin 20A/250V flush type universal modular socket switch on concealed M.S.Box including suplly of all materials ,labour T&P etc. required for proper completion of work (PWD Elec.Sch.2018 Item No.1139 A)

20

12500

625

... More
S/F hexagonal/round G.P. fan box of approved make made up of 1.0 mm thick ISI marked G.P. sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box.Holes should be semi-shuttered type with 0.5 mm G.P. sheet made upper & lower cover duly screwed fitted with 300 mm round zink coated M.S. bar X 12 MM & brand name should be embossed. Fixing with wiring conduit laid in RCC roof before concreting alongwith supply of all materials labour and T&P etc. required for proper completion of work.(PWD ELE. SCH.2018,1149)

20

3000

150

... More
Supply and Fixing of G.P. Modular switch box for 1/2 Module of approved make made up of 1.0 mm thick ISI Marked G.P. sheet including adjustable Nakka and holes plugged with PVC nylon caps.Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box.Holes should be semi-shutterd type and fitted with heavy brass earth pillar duly srewed and brand name should be embossed.Box flushed in wall including cutting of brick work ,fixing it to the level with cement sand mortar including matching colour wash including supply of all materials, labour and T&P etc.required for proper completion of the work. (PWD ELE. SCH.2018,1152A)

10

1150

115

... More
Supply and Fixing of G.P. Modular switch box for 3 Module of approved make made up of 1.0 mm thick ISI Marked G.P. sheet including adjustable Nakka and holes plugged with PVC nylon caps.Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box.Holes should be semi-shutterd type and fitted with heavy brass earth pillar duly srewed and brand name should be embossed.Box flushed in wall including cutting of brick work ,fixing it to the level with cement sand mortar including matching colour wash including supply of all materials, labour and T&P etc.required for proper completion of the work. (PWD ELE. SCH.2018,1152B)

10

1200

120

... More
Supply and Fixing of G.P. Modular switch box for 4 Module of approved make made up of 1.0 mm thick ISI Marked G.P. sheet including adjustable Nakka and holes plugged with PVC nylon caps.Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box.Holes should be semi-shutterd type and fitted with heavy brass earth pillar duly srewed and brand name should be embossed.Box flushed in wall including cutting of brick work ,fixing it to the level with cement sand mortar including matching colour wash including supply of all materials, labour and T&P etc.required for proper completion of the work. (PWD ELE. SCH.2018,1152C)

10

1300

130

... More
Supply and Fixing of G.P. Modular switch box for 6 Module of approved make made up of 1.0 mm thick ISI Marked G.P. sheet including adjustable Nakka and holes plugged with PVC nylon caps.Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box.Holes should be semi-shutterd type and fitted with heavy brass earth pillar duly srewed and brand name should be embossed.Box flushed in wall including cutting of brick work ,fixing it to the level with cement sand mortar including matching colour wash including supply of all materials, labour and T&P etc.required for proper completion of the work.(PWD ELE. SCH.2018,1152D)

10

1450

145

... More
S/F of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour, T&P etc. for proper completion of work to the satisfaction of E/I of work . (PWD SOR No. 1203A)

20

5340

267

... More
Supply and wiring of submain with two number 2.5 sq.mm FR PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2 mm thick) PVC conduit concealed in wall complete with one number 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earth continuity wire etc. complete in all respects. (PWD SOR No. 1307C)

120

14520

121

... More
Supply And Fixing of 36 Watt To 46 watt indoor Recess mounting LED Square Fitting for Armstrong ceiling having powder coated die cast aluminium housing body with extended heat sink and diffuser of special polycarbonate meterial and driver set complete in all respect. CAT-AAA (PWD ELE. SCH.2018,1406)

26

126880

4880

... More
Supply And fixing of LED tube Light with batten suitable for up to 1X22 watt LED tube light fitting including tube on surface complete in all respect. CAT-AAA (PWD ELE. SCH.2018,1413)

20

23800

1190

... More
Supply and wiring of submain with two number 4 sq.mm FR PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit concealed in wall complete with one number 2.5 sq.mm FR PVC insulated multistrand copper conductor cable as earth continuity wire etc. complete in all respects. (PWD SOR No. 221C)

98

14602

149



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.