If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Sep 2024
Closing Date7 Oct 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

E. Tender No. 23 V.p.m. (sha) / 24.25 Construction Of 01 No. 33 Kv Bay At 132 Kv Sub-station

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender Document, Details for EMD, Tender Cost Copy of UTR No and Pay in Slip of Transfer of Money through RTGS or NEFT, Experience etc. as per NIT
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
33 KV Line Isolator

1

-

-

... More
33 KV Bus Isolator

2

-

-

... More
36 KV CT 200-100/A with junction box

3

-

-

... More
36 KV PT with junction box

3

-

-

... More
Dismantling of 2 No. CCM & 1 No. CGM structure alongwith sorting, counting and shifting of dismanteled materials from switchyard to store/suitable place at S/S.

1.03

-

-

... More
Installation of 02 Nos. ABT Meter and metering cubicle with all cable laying & termination.

1

-

-

... More
Laying of following size of control cable in the cable trench from control & relay panel to various equipment in switchyard as per cable schedule its saddling at every 75mm distance with SM saddles of size 25x3mm size including carriage of cable drums form store to laying site and shifting of remaining cables back to store and all other associated works to complete the job.

-

-

-

... More
2Cx2.5 Sq.mm.

1000

-

-

... More
4Cx2.5 Sq.mm.

1500

-

-

... More
6Cx2.5 Sq.mm.

1000

-

-

... More
Termination of control cable of various euipment with switchyard to control panel and drilling of holes in control panel and junction box & circuit breaker complete with cable glands, ferrules and other associated works to complete the job.

100

-

-

... More
Dismantling of all three phase of Twin Moose ACSR conductor of 33 KV Main Bus (Length-15 Mtr.) along with opening of Jumpers, Tension fittings, 70 KN Disc insulator string etc completely, opening of connections of gantry with safety of men and materials and shifting of dismanteled material from switchyard to store including the cost of all required labour, T&P including the cost of all required labour, T&P etc.

1

-

-

... More
Laying, Tensioning & Stringing of all three phase of 33KV Main Bus having section length 18 Mtr. With Twin ACSR moose conductor alongwith fixing of suitable Bolted type Tension fittings, Making of Insulator string by jointing 70 KN Disc Insulator as per standard practice.

1

-

-

... More
Laying, Tensioning & Stringing of all three phase of 33KV Trasfer Bus having section length 6 Mtr. With Single ACSR Panther conductor alongwith fixing of suitable Bolted type Tension fittings, Making of Insulator string by jointing 70 KN Disc Insulator as per standard practice.

1

-

-

... More
Jumpering of various equipments i.e CT, PT, ISOLATOR, CB, main bus etc with ACSR Panther conductor to equipments & Bus Bar to equipments including measuring,cutting of conductor & shifting of all other associated material from store to work site.

1

-

-

... More
2 Point earthing of structure & equipments by digging of 0.7 meter deep trench in earth from equipments to sub-station earthmat which includes providing, cutting,welding and bending of MS flat as well as shifting of all other associated material from store to work site. All materials will be provided by the contractor.

-

-

-

... More
25x6mm

100

-

-

... More
50x6mm

300

-

-

... More
Painting of Earthing strip (R. Mtr.) with one coat red oxide 2 coat paint with green ISI paint including vertical support.All materials to be provided by contractor.

-

-

-

... More
25x6mm

100

-

-

... More
50x6mm

300

-

-

... More
Carraige of structure through private truck from EFU Naini, Prayagraj to 132 KV S/S Neri alongwith sorting, shifting and loading at Naini and unloading and stacking at 132 KV S/S Neri, Sitapur:-

-

-

-

... More
Sorting out and stacking of Main & auxiliary structure as per BOM at EFU Naini

5.91

-

-

... More
Loading of structure on private truck at EFU Naini

5.91

-

-

... More
Transportation of structure from EFU Naini to 132 KV S/S Neri, Sitapur (Distance approx 350 Km.)

5.91

-

-

... More
Unloading and proper stacking of structure at 132 KV S/S Neri, Sitapur as per BOM.

5.91

-

-

... More
Pilfer proofing of the cable with G.I. pipe of followng sizes complete with cutting, bending & fixing of pipe alongwith making threads, elbow and other required material from 33 KV CT & PT in switchyard to energy meter in control room.All materials labour and T&P to be provided by the contractor.

-

-

-

... More
G.I. pipe 2 " Dia

140

-

-

... More
G.I. pipe 1 " Dia

90

-

-

... More
Supply of PG Clamp duly made of LM-6 Aluminum alloy suitable for ACSR Moose to Panther conductor complete with 04 Nos. 16x90mm sisze GI Bolts & Nuts & spring/plain washers as per sample.

6

-

-

... More
Supply of PG Clamp duly made of LM-6 Aluminum alloy suitable for ACSR Panther to Panther conductor complete with 04 Nos. 16x90mm sisze GI Bolts & Nuts & spring/plain washers as per sample.

15

-

-

... More
Supply of Single tension fitting for ACSR Panther Conductor.

7

-

-

... More
IEC 61850 based SCADA configuration & its integration with 33 KV bay. Work includes SLD generaion for feeder bay in existing HMI, bay IED 's ICD files configuration data base creation for new bay, event, alarm generation, interlocks & soft logics, configuration, testing, GPS time synchronisation for proper operation of all equipments through SCADA & BCU.

1

-

-

... More
Supply of Fibre Optical Cable (6 fibre) suitable for communication between LIU to LIU of SAS system.

220

-

-

... More
Supply of fibre Optical Multinode patch cords for ST-MTRJ Ports (each 3/5 Meter)

10

-

-

... More
Supply of Fibre Optical Multinode patch cords for LC-LC ports (each 10 Meter).

5

-

-

... More
Supply of Fibre Optical Multinode patch cords for ST-ST ports (each 10 Meter).

5

-

-

... More
Hot dip galvanized, Hexagon round hexagon head Nut bolts, 'U' Bolts for main & auxiliary structure as per BOM of required structure.

220

-

-

... More
Fee for electrical safety to be paid by contractor for obtaining 'No objection Certificate' from office of Electrical safety U.P. Govt. Lucknow before charging of New 01 No. 33KV Independent feeder bay (M/s Saga Ventures Pvt. Ltd.) at 132KV S/S Neri, Sitapur.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.