Uttar Pradesh Housing And Development Board Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Housing And Development Board - UPAVP Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Feb 2024
Closing Date23 Feb 2024
Tender Amount₹ 28,60,000
Costs
EMD
₹ 57,000Document Cost
₹ 1,770Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPHDB_896591_1Bid Award Id
ViewTender No
S.No.-5/NIT-NO-287/UPHDB/ DATED 07/02/2024Tender Authority
Uttar Pradesh Housing And Development Board ViewPurchaser Address
-Website
http://https://upavp.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints,surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 ( Part II 1981 ) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used. The rate of application of chemical emulsion shallbe as follows : (1 Treatment for masonary & foundation 5 liters pe r/ 100 Sqm.(2) Back fill in immediate contact with foundation 7.5 liters / 100 Sqm. (3) Treatment of top surface of plinth filling 5 liters / 100 Sqm. (4)Treatment junction of wall and the floor 7.5 liters / 100 Sqm. (5)Treatment of soil along external perimeter of building 7.5liters / 10 Sqm.(6) Treatment of soil under apron along external perimter 5 liters / 100 Sqm.
139.89
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Bands (Ground Floor + First Floor)
6.62
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slab (Ground Floor)
19.05
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Beams (Ground Floor)
3.01
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
9.54
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (Ground Floor)
5.95
-
-
Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 15 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deepcomplete in cement mortar 1:6 (1 cement : 6 coarse sand). From ground level upto plinth level.
39.95
-
-
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
12.06
-
-
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
12.06
-
-
Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 15 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deepcomplete in cement mortar 1:6 (1 cement : 6 coarse sand) Above plinth level upto floor V level. (Ground Floor)
40
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (Ground Floor + First Floor)
55.88
-
-
15 mm thick plinth plaster [1 cement : 4 coarse sand]
49.63
-
-
15 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) (Ground Floor)
200.06
-
-
12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) (Ground Floor + First Floor)
224.73
-
-
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
467.68
-
-
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm (Ground Floor)
90.27
-
-
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (Ground Floor)
5.48
-
-
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (25 mm thick) (Ground Floor)
54.4
-
-
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (Ground Floor)
3.06
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
32.63
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
10.08
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
38.64
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
414
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
517.5
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
261
-
-
Fixing to steel or wooden chaukhats in position.
(a) Door chaukhats
4
-
-
Fixing to steel or wooden chaukhats in position.
(b) Window chaukhats
8
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer (Ground Floor)
200.06
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). (Ground Floor)
185.38
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). (First Floor)
39.35
-
-
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (Ground Floor)
131.76
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (Ground Floor)
556.55
-
-
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
4
-
-
Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm
4
-
-
P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. (a) 250 mm x 10mm
4
-
-
Providing & fixing stainless steel door handles with screws and 150mm long.SI marked
8
-
-
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
133.99
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
30.78
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
20.16
-
-
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes
20.7
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for : Suspended floors, roofs, landings, balconies and access
platform
138.09
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
77.3
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases of columns, etc. for mass concrete
32.78
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, Pillars, Piers, Abutments, Posts and Struts
83.06
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion(i) Single socketed pipes. (110 MM )
18
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.COUPLER
4
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.COUPLER (BEND 110 MM)
8
-
-
Providing and fixing to the inlet mouth of rain water pipe cast irongrating 15 cm diameter and weighing not less than 440 grams.
4
-
-
Providing and fixing unplasticised -PVC pipe clips of approved designto unplasticised - PVC rain water pipes by means of 50x50x50 mmhard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete
16
-
-
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. a) 110mm
4
-
-
Wiring for light point/fan point/exhaust fan point/call bell pointwith 1.5 sqmm FR PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit,with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. (Group C )
40
-
-
Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.
2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire
70
-
-
Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.
2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire
80
-
-
Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.
2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire
50
-
-
Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 20 mm.
25
-
-
Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :
25 mm.
75
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
2 pair
20
-
-
Supplying and fixing metal box of following size (nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in fromt including paintingetc. as required.
75 mm x 75 mm x 60 mm deep
4
-
-
Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
4
-
-
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
8
-
-
Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connection, painting etc. as required.
12
-
-
Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps. modular socket outlet and 15/16 amps. modular switch, connection, painting etc. as required.
2
-
-
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (single pole)
8
-
-
Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
2
-
-
Supplying and fixing following rating,four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps.
2
-
-
Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
12
-
-
Providing and fixing of circular / hexazonal cast ironor MS sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick MS sheetwith it top surface hacked for proer bonding, top lid shall be screwed into the cost iron/MS sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shal be made of 12 mm dia MS bar bent to shape as per standard drawing.
12
-
-
Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.
2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire
40
-
-
Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.
4 x 25 sqmm with 2 x 16 sqmm earth wire in 50 mm dia conduit.
50
-
-
S/F of single light wall bracket (Cat-AAA) on matching M.D.F.E.G. board base etc. complete in all respects. Category AA
2
-
-
Supply and fixing of LED Tube Light batten fittingsuitable for up to 1 X 22 watt LED tube light onsurface complete in all respect. (Category AA)
16
-
-
Supply of ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS : 374/79 and also comply with IS:1709/1984 with latest amendment the rated voltage 220/240 volts, 50 HZ single phase AC, the fan assembled should consists of down rod, blades, shackle canopies etc and with double ball bearing system.
BEE 5 star rating - 1200 mm sweep
12
-
-
Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6 sqmm cables, including tapping with insulating tape, etc. complete in all respects.
46
-
-
S/F of sheet steel enclosure for DP / TP / FP MCB with neutral link and earth terminal. Cat-A
2
-
-
Supply & fixing of electronic Fan regulator (Modular), 120-280 V, ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer of work.
12
-
-
S&F surface/flush mounting 4 ways SPN distribution board with additional metal door without MCB completein all respect, as directed at site by Engineer in charge.